Loading...
RF-17-2708 (2)Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Permit NO. RF-1 1-17-2708 Permit Type: Roof Work Classification: Tile/Flat Permit Status: APPROVED I ssue Date: 11/20/2017 Expiration: 05/19/2018 Parcel Number Applicant 365 NE 93 Street Miami Shores, FL 33138- 1132060136300 Block: Lot: ABEER & MOHAMMAD JADALL4 Owner Information Address Phone CeII ABEER & MOHAMMAD JADALLAH 365 NE 93 Street MIAMI SHORES FL 33138-2854 Contractor(s) T&S ROOFING SYSTEMS INC. Phone 305/265-2654 CeII Phone Valuation: $ 22,000.00 Total Sq Feet: 3000 Type of Work: Re Roof Additional Info: RE -ROOF TILE & FLAT Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $13.20 $4.50 $3.00 $4.40 $300.00 $9.00 $17.60 $851.70 Pay Date Invoice # 11/20/2017 11/15/2017 Bond #: 3563 Pay Type RF-11-17-65652 Credit Card Credit Card Amt Paid Amt Due $ 801.70 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Roof in Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility f r all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECFJANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I construction an. zoning. i Au ertify t :t a I the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating utherrpore, authorize the above -named contractor to do the work stated. rized • ' • na u e: Ow - r / A cant / Contractor / Agent November 20, 2017 Date Building Dep : rtment November 20, 2017 0 Y 1 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC PLUMBING ❑ MECHANICAL JOB ADDRESS: Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 Master Permit RECEIVED NOV 15 7017 Bi2 2oU No. p-r n'Z�S Sub Permit No. ❑'ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores County: Folio/Parcel#: 6 3 od Occupancy Type: Load: Construction Type: OWNER: Name (Fee Simple Titleh_older): 1� r �RI ' t4 d Phone#: 6 ) VCH City: "\ \ 11/WI 4vi r Q S State: Zip: JYj Tenant/Lessee Name: Phone#: Miami Dade Zip: Is the Building Historically Designated: Yes NO Address: Flood Zone: Y(A0\0% BFE: FFE: Email: CONTRACTOR: Company NameS Address: 1 �lQ vv 2 '' City: Qualifier Name: Phone#: Stage: `+ L- Zip: 31 y 2. State Certification or Registration #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Phone#: l Value of Work for this Permit: $ 71 / OGO Type of Work: ❑ Additio Alt -ration Description of Wo 1Z�Qc� 2 Certificate of Competency #: Square/Linear Footage of Work: J mod' New ❑ liepair/Replace I€ ❑ Demolition Specify color of color thru tile: Gold \I5r1 Submittal Fee $ Permit Fee $ CCF $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CO/CC $ Notary $ Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ ON ' 0 4 , Bonding Company's Name (if applicable) Boriding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this M day —� �'P/e� �; who is personally known to 'me or who has pr duced as identification and who did take an oath. NOTARY PUBLIC: , 20 by Signature The foreg CONTRACTOR ng instrument was acknowledged before me this ,20 17 ,by day of CAis� ) 0, who is personally known to. me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign. /� , _� Ign: 1 Print ,� rfnt:- Seal: DANIELPEREZ Notary Public - State ^ Commission = GO My Comm. Ex ,fires N. . 2020 Seal: DANIEL PEREZ Notary Public - State of Florida Commission : GC 44769 My Comm. Expires Nov 3.2020 as *******************************,** *********************************************************************** g11 APPROVED BY Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Sworn to and subscribed before me this hores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 . i J Re: Owner's Name: AlOe d ('\ d C i I o A Property Address: VS qRoofing Permit Number:(-L Dear Building Official' I \oe eif 4,t\«\[\,certify that I am not required to retrofit the roof to wall connections of m y builcing because: U cfhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00, Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) r /L Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned, t\IN 1) 4 ..... A 1 day of Notary Public, Sate of Florida at Larg i N When the just valuation of the structure for purpose ad valorem tax lion is equal t SFBC. Then you must provide a building application from a General C DANIELPEREZ Notary Public - State of Florida Commission GG 44769 My Comm. Expires Nov 3, 200 9 or ore than S300,000.00, and the building was not constructed with FBC nor a 1994 ntractor for t e oof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-6300 Property Address: 365 NE 93 ST Miami Shores, FL 33138-2854 Owner MOHAMMAD N JADALLAH &W ABEER Mailing Address 365 NE 93 ST MIAMI SHORES, FL 33138-2854 PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,449 Sq.Ft Lot Size 9,287.68 Sq.Ft Year Built 1967 Assessment Information Year 2017 2016 2015 Land Value $278,444 $232,402 $222,901 Building Value $172,021 $173,441 $174,862 XF Value $3,968 $4,035 $2,889 Market Value $454,433 $409,878 $400,652 Assessed Value $171,880 $168,345 $167,175 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $282,553 $241,533 $233,477 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. Coun y, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 25 & W22.56FT OF LOT 26 BLK 46 LOT SIZE 72.560 X 128 OR 15586-0612 0792 1 Generated On : 9/13/2017 Taxable Value Information 2017 2016 2015 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $121,880 $118,345 $117,175 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $146,880 $143,345 $142,175 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $121,880 $118,345 $117,175 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $121,880 $118,345 $117,175 Sales Information Previous Sale Price OR Book -Page Qualification Description 07/01/1992 $140,000 15586-0612 Sales which are qualified 06/01/1988 $131,000 13745-1786 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: V1 Low Slope Roof Area (SF) WO Master Permit No. Contractor's Name Job Address ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Process No, RECEIVED Ob (•PE -- Low Slope 0 Asphaltic Shingles , ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF TYPE 3 ` Mortar/Adhesive Set hies • 1 0 Wood Shingles/Shake% •••�•• •• • ❑ New roof 0 Repair 0 Maintenance ❑ Reroofing • • • •p ROOF SYSTEM INFORMATION ""• Steep Sloped Roof AREA (SSF) VICOTotal (SF) M' ▪ • Section 8 (Roof Plan) • • a'‘ Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and oliQrlibw;drains.dndude•d men' 1 sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ' • • >- m 0 w INTERNATIONAL CODE COUNCIL w 0 (� z z 0 w r-- C) fi c^� a fJ reml =? a� "4-5e) FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by F.liezer Palacio on Jun 8, 2015 10:32:12 Aht pursuant to License Agreement. No further reproductions authorized. 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 • "Delivering Excellence Every Day" Rcof System Manufacturer: Rliiarni-Dade County HlfHZ Electronic Roof Permit Form Section D Tile Roof System BORAL ROOFING LLC Notice of Acceptance Number (NOA): I+ I t` I I tv Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P1: 39.1 P 2: 68.1 P 3: 1100.7 Maximum Design Wind Pressures, (From the NOA Specific system): 29-3 _ psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: Roof Mean Height: "/12" 115 Method of Tile Attachment: ft. -Adhesive, 2 Small Paddy Polyfoam Polypro- Alternate Method of Tile Attachment per NOA: Drip Edge Size & Gauge: Drip Edge Material Type: -- Select Metal Gauge :--Galvinized Metal -- Drip Edge Fastener Type: L Hook Strip/Cleat gauge or weight: -- Select Hook Strip, -- Deck Type: --5/8" Plywood — .-J- • • • Optional Insulation: •• • • • • • • • • • .,._. • • • Optional Nailable Substrate ••• • •.• • • • •• • • • • • . • • • • • • • • • • Optional Nailable Substrate Attachment •.; � • • • • Basesheet Type: #30 astm type II Fastener Type for Basesheet Attachment: j1 1/4 RS NAILS 6" OC AND 12" FIELD Tile Underlayment (Cap Sheet ) Type: 1TILE SEAL Tile Underlayment Attachment Method: SELF ADHERED Tile Profile: 'BARCELONA 900 RBI MWADE "Delivering Excellence Every Day" Miami -Dads: Count; HVHZ Electronic Roof Permit Form 7 Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the vnlues for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P 3: 39.1 68.1 100.7 xX x� o7)U1 .i.In6 - Mg: iOj = Mr1: - Mg: =130e31-Mg: h.l .®A. 1-1 NI = Mr2: 0(.1v = Mr3: 6 '. 3.__; < 29..3 i 29.3 '29.3 NOA Mf NOA Mf NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127': •• • •• • • • • • .• • 'or Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are groats:ikon or equal to the Fr J'� ,{pr !ach area of the roof, then the tile attachment method is acceptable. • • • • • • • • • • 1: xl: xl: x w: = x w: x w: - W: - W: - W: x cos 6: x cos 6: x cos 6: = Fr1: = Fr2: = Fr3: •••• r• •• • • ♦ • -• • •• • -- 1< Where to Obtain Information to complete tile calculations • ♦ ••• • NOAF' • • • nbA F' • ••• • • • it6AF' •• • Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. r Mean Roof Height I H Job Site Roof Slope Aerodynamic Multiplier 6 Job Site X Product Approval (NOA) — Restoring Moment due to Gravity ; Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) — Calculated Required Moment Resistance Mr Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W s y� I = length Tile Dimensions i w = width Product Approval (NOA) Product Approval (NOA) DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY I'R:ODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F. (786) 315-2599 www•.miamidade.2ov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product tieControl Section •••••• (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve rrgl1t to have this product or material tested for quality assurance purposes. If this product or material fails to pteforrh in thLvapted manner, the manufacturer will incur the expense of such testing and the AHJ may immediatelMoke, modify, or • suspend the use of such product or material within their jurisdiction. RER reserves the right :o r.eyoke this acc;ptance• if it is determined by Miami -Dade County Product Control Section that this product or matefi4 kits to rottt rile requirements of the applicable building code. • • • • This product is approved as described herein, and has been designed to comply with the Flotilla $uildingb de • including the High Velocity Hurricane Zone of the Florida Building Code. • • • • •' • . • • DESCRIPTION: Barcelona 900 Concrete Roof Tile • • •• ••• • ..• . . • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure tocomplywith any section of this NOA shall be cause for termination and removal of NOA. • • • • • • • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0222.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMM•DADE COUNTY NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 1 of 7 • ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Barcelona 900 Length = 17" Width = 13 'h" thick Trim Pieces Length: varies Width: varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL 2.2 SUBMITTED EVIDENCE: Test Agency Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Test Specifications TAS 112 Type — la TAS-112 Test Identifier 7161-03 Appendix III 7161-03 Appendix II P0402 Letter Dated Aug. 1, 1994 P0631-01 Product . • Description • . High profile, interloolang!one-pjea. n' shaped, • . high-pressure extruded:bficrete goof tile • equipped with three naii holes. For direct des• • • • or battened nail -on, chanicallZ festeded, • mortar set or adhesiyg.s applications.. • . . . . ..• .. .•• • Accessory trim, boob tBttrcelona, concrete roof pieces for use at hips,7akes,Xidg$s.and valley terminations u'hanufacturedfor each tile. • • • • .. . ..• • • profile. • • • • • Test Name/Report Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108(Nail-On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Date Dec. 1991 Dec. 1991. Sept. 1993 Aug. 1994 July 1994 NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 2 of 7 Professional Service Industries, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. IC-1320-94 25-7688-3 25-7688-10 25-7688-5 The Center for Applied Engineering, Inc. 25-7688-4 Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida 3. LIMITATIONS: 520111-3 520191-2-1 Calculations Evaluation Calculations RT0617.03-16 Physical Properties TAS 112 TAS 101 (Adhesive Set) TAS 101 (Mortar Set) Static Uplift Testing TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing TAS 102 (4" Headlap, Nails, Clips) Static Uplift Testing TAS 101 Aerodynamic Multiplier Restoring Moments Due to Gravity: . • . TAS 112. .. . Feb. 1995 June 1996 July 1996 June 1996 June 1996 Dec. 1998 March 1999 09/01/16 :. QAQ1 /16 • : • OM729/16 • • . •.. 3.1 Fire classification is not part of this acceptance. • •• •• • •• 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance yvit ,T.A.S 106 may required, refer to applicable building code. • • • • • 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarter y test ir: accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Department of Reg i14ory • • • and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 3 of 7 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3r) Direct Deck Application Barcelona 900 0.286 0.301 • ' Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf), .•. •Tile Profile 2":12" 3":12" 4":12" 5":12" 6";t2v "" :7:':i2" or:•• greater "i Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens..nject . • dl(iirk Ba'ttsns: • Direot•. Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 : C.670 5.76 • 6.42 • • • ..• • . • ... • •.• • .. ' •. •.• • • • ••• • Table 4: Attachment Resistance Expressed as a Moment - Mr (fN Ib)) "'• ' ' for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 MIAMIOADE COUNTY APLIROVED NDA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 4 of 7 • Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" tile headlap and fasteners are located a min. of 2'/2" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Adhesive' 29.32 . 1 See manufactures component approval for installation requirements. ••• 2 TILE BONDTM Roof Tile Adhesive; Average weight per paddy 10.7 grams. • •. • • • • ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per paddySgrams. • • • • • • ..• • • Table 7: Attachment Resistance Expressed as a Moment - Muttlbt) •for Single Paddy Adhesive Set Systems ' • • • •• • ••• •.4 Tile Profile Tile Application •Minimum Attecimient••' • • Resistante • .• Barcelona 900 ICP Adhesives Polyset AH-160 . • 66:53''' • • ICP Adhesives Polyset AH-160 •• • • • • 38•.» . • • 3 Large paddy placement of 63 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160. • • 4 Medium paddy placement of 24 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set5 24.5 6 See specific mortar manufacturers Notice of Acceptance MIAMI•DADE COUNTY .PROYED NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 5 of 7 ••• • •• � • ••• • • ••• 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE • 6. BUILDING PERMIT REQUIREMENTS • • • • • • • • 6.1 Application for building permit shall be accompanied by copies of the followi• • • following.: • 6.1.1 This Notice of Acceptance. • 6.1.2 Any other documents required by the Building Official or applicable building code ie order to • • properly evaluate the installation of this system. • :'. • • • • • ••• • • • •• •• •• • • • irKq- MIAMI•DADE COUNTY • • • • • • • • • •• •• • • • • • NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page6of7 • PROFILE DRAWING NAIL HOLES UNDERLOCK OVERLOCK BARCELONA 900 CONCRETE ROOF TILE EN M1AMI.DADE COUNTY AEPRQVED 11 OF THIS ACCEPTANCE 13" . . 3 5/$ „ • .. . . . • .... . . . . .. • . . • • • • • • • .. • • ••• • •• ..• ••• • .. .. • • • • • • • • • • • • • • • . NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 7 of 7 PsiFAMII,M Mat DEPARTIvhENTOF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL. 33065 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/ecmiomv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (Tn Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted as Viler, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, nciodif% or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke stills accept:pm„ if it is determined by Miami -Dade County Product Control Section that this product or material fails ¶Q:Met the•requirements' of the applicable building code. • • .... . . • • • This product is approved as described herein, and has been designed to comply with tlfe. F:ar'ida Bkrllirig Cod& • •• • • including the High Velocity Hurricane Zone of the Florida Building Code. •• •• •• •• • • .• .. ••• • DESCRIPTION: ICP Adhesives Polyset® AH-160 • . • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, City State ahtl'fpllbwing' statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • • • • • .• • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 APproval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive` ' Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as,manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Product Description Two component polyurethane fol$iadhesive• Dispensing Equipment • •••• •• Dispensing Equipment • • • • • • ••• •. • • • • Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA•which list attav1 lent resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. • •, •• • • • • • • • • ••• • • • •• • • • • MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D;1,621 • ASTMD 1623 ASTM D 2127 ASTM E 96 ASTM.D.2126 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks A.STM85,6... 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMI•DADE COUNTY fit, APPROVED .10 vs: • •• • • • • NOA No.: 17-0322.0 •y=; •r • • • Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report . Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-743 8-4, 25-7438-7 . SSTD .11-93 11/02/95 25-7492 `SST1.3 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 Oliva. . • • Trinity Engineering 7050.02.96-1 TAS 114 • • ' 03i1,4✓4t• P36700.04.12 ASTM D 1623 • 04718/12 P39740.02.12 TAS 101 • • 02/•21/12 TAS 123 ••...• . • ••• Celotex Corp. Testing Services 528454-2-1 TAS 101 • •' • •' 1072 A8 528454-9-1 • 528454-10-1 • • 520109-1 TAS 101 : . • • 12/28/98 520109-2 • • 520109-3 •�� 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 •• • • .• • • • LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI.DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3of11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintaineeltween 1.0-1.15 (A): 1.0 (B). •• ••• • • •• 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser R'1'I 1'C100 or ?CP Adhesives ProPack® 30 & 100 dispensing equipment only. • 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. • • • • 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minute? a t& SCP Adnes v®s Polyset® AH-160 has been dispensed. • • 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accopdance:with tl�� •,,; • 'Placement Details' herein. Each generic tile profile requires the specific placement noted hc,cji,n. • MIAMbDADE COUNTY APPROVED •• • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 • • • • •• • • Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave e Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at overlap 12 grams per paddy Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal edge) 20-25 sq. inches each bead 17 grams perbead • .. •• • • • ,• • • • Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches ... grams uncjer pan LABELING: • • • • • • • • • • ••• • • •• • • ••• •• • •• • • ••.• • •• •••• • •••• • • • All approved products listed herein shall be labeled and shall bear the imprint or identifiable markipgof the • manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or4he Miami - Dade County Product Control Seal as shown below. • •• • •• • • •• • • •• • ••• • • • BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 Paddy il3kaaath. IO ADHESIVE PLACEMENT DETAIL # 1 Half through. pia.tiE riri:•nt l: tait•qulrad'r Iv wrens optional Eva Cour+e. Nail t r'u9h plasm cement iwh.n required) } €ram ltri , n tt , ,rr Niltht i1g.hpierlicter,.reir 4tibettrequlrttl} r' MIAMI•DADE COUNTY APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pin • •• • • • 1. Starting at the eave cours.7a'1Y a minimum 2" (50.8 mm) x 10" (254 mm)•x 1 ' (25.4 inm) loam paddy onto the underlayntegp,ptitionertSSIlown under the pan portion of ttg4i Closest to the• overlock of the tile being cof...•• • • • 2. Continue in same manner!Insure apprcr.ii gly 17 (109.7 cm2) — 23 (148.4 c>ti2) square inch adhesive • contact with the underside of the tile. • • � • • • • • . • • • • High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 • ADHESIVE PLACEMENT DETAIL # 2 fv:]i! Ihr ni jh plai'ic. iema�i! .y In, "a,., Dari.irs apt ,naI E75tiChUtiit., Nail thrat}pilplasticcement in,vh?nregniredl t _ _ Paddy;Bneaalttil0 MIAMI•DADE COUNTY APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. I�isure•approx• jriiiitt'1, 10" (64.5 cm2) - 12 (77.4 cm2) sY Pe :rich adhesive •• contact with the underside of die.tile. • • • ..•. • • • • • Medium Profile / Double Pan T Tr' ' 1. • • • • • • • • • • • Starting at the eave course, �i�ly.4 minimum 2t (50.8 mm) x 10" (254 mm) x 1" (25.4 inn) fo4,m paddy onto the underlayment positioned as sho)f ITder the pan portion of the tile closest•to'the overlook oithe • tile being set. Insure approximately 17 (109.:1 cin2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) •. • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 MIAMI.DADE COUNTY APPROVED tir: th;rj ADHESIVE PLACEMENT DETAIL # 2,(C:ONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. • 3. Continue in same manner. Ihuit a,l)proxixnate:y 17" (109.7 cm2) - 19 (122.6 cm2 sappre inch adhesive contact with the underside of the ti4e. • .... • •••• • .. .. • ••• • • • • •• • • • • • • • • • • • • • • • •• • • ... • .• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 7 • Fisc(a ADHESIVE PLACEMENT DETAIL # 3 Nail through plasticcement Paddy (b tweentiies) {when requiredi ys t Battens optional r.i /. 4' Paddy !under tile) •'. Single paddy on top of the ezain. Single pad under ti e Singlepaddy} an underlayment 2sr4in. 10in`: A. 2 m. .-— -EaveClosure Flat/Low Profile The Nail through plastic cement SinglepaddyundertBz �— � Paddy (betweentiles) r{ / Paddy (under [when required) Medium Profile Tile 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foarruilt under the strengthening ri% foef at tile'or under the pan portion of the tile, closest to the urlderkkk for the second course tile to be installed. Ensure approximately 8-9 in2 (51.Wj3.1 cm2) Qf adhesive contact with the undersidi3 pf th2 tile. . •... . . . . . ..• .. ..• • (Instructions continued on ne;'p& ) • •• .. . ... • • • • . • • NOA No.: 17-0322.03. Expiration Date: 05/10/22 Approval Date: 04/27/17 :Page • ADHESIVE PLACEMENT DETAIL # l(CONTINUED) Nail through plastic c? Sinai? paddy under the (when required) f Paddy !between tiFesj Paddy (under tile( (;. f. ;7 Fascia Weephole Eavedosure toin y," Drip edge_ High ProfileTife MANMADE COUNTY Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. in contact with the pan tile. 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in.contact area. Underlayment Eave closure (motar shown) Weephole Fascia Board Steep pitch applications (when required) Sheathing Remove top portion of the eave course cover tile.Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High ProfileTile MIAMI DADE COUNTY APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. • • 3. Turn covers upside do` in e.x psing the underside' • of the tile. Apply a minihfum•1" (25:4 x 10" •. (254 mm) bead of adhesive airectly on the inner edge of each side of the mir tile. Leave. • approximately 3/4" (19'vyglto 1" (21.tl i2ttn) from the outside edge afhe.tile, inward, free of • • •foam to allow for expaxmio i, • • • • • 4. Turn cover tile over after foadi is appl,W, ud place onto pan tile coua'.se. i$s ire a rhinimum of 20 (129 cm2) - 25 (161.3•cm2Tsquareineh: contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 • • •.•.•• DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/cconomv This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve thej fight• o haver 4I�� .• • product or material tested for quality assurance purposes. If this product or material fails to peffpf ip the vcepied manner, the manufacturer will incur the expense of such testing and the AHJ may immediately.rseazoke, modif?,•dr• suspend the use of such product or material within their jurisdiction. RER reserves the right to Isa4oke this acceptance, • if it is determined by Miami -Dade County Product Control Section that this product or materiajfaMs jo meeiiM:, requirements of the applicable building code. • • •• • This product is approved as described herein, and has been designed to comply with the Florida i lling Co$e: including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • DESCRIPTION: BORAL TileSeal • • • • • ... • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • • • • • •. • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renewer NOA#13-1113.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Freddy Semino MANMADE COUNTY APPROVED NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 1 of 4 • ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS PRODUCTS DESCRIPTION: Product BORAL TileSeal Dimensions 36" x 36' rolls 36" x 72' rolls MANUFACTURING LOCATION: 1. Brentwood, NH EVIDENCE SUBMITTED: Test Agency Underwriters Laboratories, Inc. IRT-Arcon, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Construction Materials Technologies, LLC. Test Specification TAS 103 ASTM D 1970 Test Identifier R14610 02-012 NEI-006-02-01 NEI-008-02-01 NEI-045-02-01 NEI-053-02-01 NEI-076-02-01 NEI-034-02-02 Product Description SBS self -adhering asphalt sheet material with a white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. . . . .. • . Test Name/Report • •..' • • Date Follow up Service •••••• •01128<02. TAS 103 • 02/'28/02 . . • • • • • • TAS 103 • :64M '02 TAS 114 (H) • • • '07/3i'02 • ASTM D 4798 & ASTM G 155 08/08/07 ASTM D 4798 & ASTM G 155 05/01/08 TAS 103 / ASTM D4798 02/14/11 ASTM D 1970 01/29/13 NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Deck Description: System E(1): Base Sheet: Membrane: Surfacing: Wood, non -insulated 15/32" or greater plywood or wood plank Anchor sheet mechanically fastened deck, membrane adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. ' • • • • • . • Note: When used in Tile roof systems BORAL TileSeal Underlayment �l;•lj pp back• , ra�ik to deck with approved annular ring shank nails and tin caps at a maximum, '.4.c. at the sidg laps. No nails or tin caps shall be exposed. •.... .... • Approved for Approved Adhesive Set Roof Tile Systems, Mechanically'1' s1 i ed Rof Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies." . • • • • . . ••• • NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". • • 9. BORAL TileSeal underlayment may be used with any approved roof covering Notio t o€•Acceptancelisting BORAL TileSeal underlayment as a component part of an assembly in the Notice of A.mi2tiance.:>'Af3TORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Ju Qiaion (MIL) or the Miami -Dade County Product Control Department for approval provided that appropsiata docuiientaiion is • • provided to detail compatibility of the products, wind uplift resistance, and fire testing resullst • • •• • 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose: ygnilig paiiels: ggweep the deck thoroughly to remove any dust and debris prior to application. • • • 11. When applying the membrane in the valley, start at the low point and work to the high poitt, robing the membrane • from the center outward in both directions. For ridge applications, center the membrane:ancl i4411 from the center • outward in both directions. • • • • • • •• • .• • 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special atte• ntion to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below MIAMI DADE COUNTY APPROVED END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 4 of 4 • • Miarni-Dade County 1:11,11-2 Electronic RAfyi Permit Form Section C Page (Loyd'Slope F(UR ROof Systems) FJJ:sp,-cific roof gszembfy compon -ants. !fa con pcnen Fr iS not requirec_1; 'insert not a,oplicalifol):, IRoof System Manfacturcr: GAF Base Sneet(C, [Pzoduct Approval (NOAd I iLtjtii•W•J NOA System Type: 7)nd Uplift Pressures, Frorn RAS 128 or Se.aled Calculations: (P1) Fel;;:l 42.8 I psf F3) Corners: (P2) Perimeters: 108 psf . 71.7 • • . Maximum Design Pressure From NOA: -52.5 (P2) Perimeter (a') Size: Tt. FRoof Slope: Parapet Walls: I E/] No 0 Yes (P3) Corner Size: a' psf psf • (x) a' Roof Mean Height: 12 Parapet wall Height I ft. ft. 5/3" Plywood Deck-- LWIC Manufacturer Compressive Strength' psi Support Spacing: Existing Roof (For Recovers Only): ft. o/c L 'Fire Barrier:I Vapor Barrier. Anchor Sheet: Anchor Sheet Fastener/Bonding Material: Insulation Base Layer Size & Thickness: Insulation Base Layer Fastener / Bonding Material: Insulation Top Layer Size & Thickness: Insulation Top Layer Fastener / Bonding Material: Field: INumber of Fasteners per Insulation Board: Perimeted Corner: #75 BASn Sti..:L 1 Base Sheet Fastener Bonding 1%.4alrial:]. 1 1/4 RS NAILS I Ply Sheet(S)1 PLY IV (2) Ply Sheet Fastener/ Bonding Materiaq ASPHALT TYPE IV . 1 Top Ply Shr.TW.1 -• — MINERAL SURFACE CAPSHEET Top Ply Sheet Fastener / Bonding M afe'riai: . • ASPHALT T': Optional Suilfatihr (P1)Field: • • • • • • • • • • • • • • • • • • • • 111 111 IIA,•• • Fastener Spacing for Bast' ttactitj • •• • • • • • • • • • • • • • in. ok L1JRoP. k:16 lin. o/c • • • • • • in. o/c Row(s) I in. o/c Row(s) 4 lin. o/c (P2) Perimeter: (P3)Corner: Lap Spacing 6 4 • 4 6 Wood Nailer Type and Size: j Wood Nailer Fastener Type and Spacing:1 -- Galvanized Edge Metal -- -- 3" Face 26 Gauge -- I -- SELECT EDGE METAL HOOK STRIP SIZE -- Edge Metal Attachment: 1 1/4 RS.NAILS ETPARAPET WALL COPING MATERIAL • -- SELECT COPING METAL SIZE OR THICKNESS -- 1---------S-E-L—Eal CO -PING METAL HOOK STRIP SIZE -- - Parapet Coping Metal Attachrn.ent: • . . . __..: •----- --T....T.-- Reset Forrn FPrint Form Parapet Wall Nailable Deck Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS-111 and Chapter 16. -71 so 4 - 4 Concrete wall Elastomeric sealant tooled to facilitate water run-off Optional: compressible _ = Elastomeric sealant Metal counterflashing mech. __attached 8" ofc w/ washer Seal top of base flashing wf _ - comptable material Termination bar mech. =-=attached 6"ofc Field plies turned up wall Base flashing min. _ - 8" above finished roof -Top Ply .Interplies r ' - Balse Sheet -Roof Deck • • • • • •• • Parapet wall height! • • • • • • ft • Roof Mean Heigli4? • ft. •••• • ••• • • •• • . ••• •. ••• • Base Flashing.. . • IRUBERIOD 170 FR•• . . . • Surfacing: Top Ply: • • • • • • • • • • • • •_- • • ..• • • • • • MINERAL SURFACE CAPSHEET Inter Ply Sheet: PLYIV(2) Base Sheet: 75 BASE SHEET Roof Deck Type: 15/8 CDX PLYWOOD 1:d*arl rEeAtck • 1-2 MMnnpp 4 u'VOSa7'U0'124.00 JDdive fin n Ercelleaue Every DAy" iViaini.Dade CougylIVIEZEiifedroi o Roof PaintForm • MI/skate Components Noted and Details as Applicable: Hod Park. )Roof Mean Reag]kt: Meta][: 13X3 GALV 26 GA Surfacing: • • • ••• •• • • • • • •••• • • • • • • • • • • •• •• •• • • • • • • •• • Top Ply: -- — JIMINERALSURFACE CAPSHEET Jnier'plies PLY IV (2) Base Sheet: #75 BASESHEE l Elea( Type: _ _ `5/8 CDXPLYWOOD • • ••• • • • • • • • • •• • • • • • • • • • • • • • • • •• El Ai I!--5H DE • 11EPAR.T MVENT OF RE,GULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ;GAFF 1 Campus Drive Parsippany, NS 07054 Mrs ?-DAD r, COUNT' PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidadeQ(v/economy SCOPE: This NDA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product •• Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) • • • • reserve the right to have this product or material tested for quality assurance purposes. If this protifict o'r • material fails to perform in the accepted manner, the manufacturer will incur the expense of suchn �tn • • • and the AHJ may immediately revoke, modify, or suspend the use of such product or material wititjheir • jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dad2nty • • Product Control Section that this product or material fails to meet the requirements of the applicable.. •• • • • • •• building code. • • • • • . • • • • . •. This product is approved as described herein, and has been designed to comply with the Florida I: uildirig Code • including the High Velocity Hurricane Zone of the Florida Building Code.•• •• .. • DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. •.• • •. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. R. l`./ • • • • MIAMI•DADE COUNTY 0 ED T, NOA No.: 14-1030.01 Expiration Date: 11/04/i Approval Date: 05/04/17 Page 1 of 11 ]RnOFING ;SYSTEM 2A PPRc9 tTAL Category: Sub -Category: Material: Deck Type: Maximum Design. TIRADE NAMES Product GAFGLAS® Ply 4 Tri-Ply® Ply 4 GAFGLAS® FlexPly" 6 GAFGLAS®#75 Base Sheet Tri-Ply® #75 Base Sheet GAFGLAS® #80 Ultima'Base Sheet GAFGLAS® Stratavent® Perforated Venting Base Sheet GAFGLAS® S tratavent® Nail abl e Venting Base Sheet Ruberoid® 20 Smooth Ruberoid® Mop Smooth Ruberoid® Mop Smooth 1.5 Ruberoid® Mop Plus Smooth Ruberoid® HW 25 Smooth Pressure: Roofing BUR Fiberglass Wood -97.5 psf. OF PRODUCTS MANUFACTURED ED OR LABELED BY APPLICANT TABLE 1 Dirnens ion s 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide Test Specification ASTM D2178 ASTM D2178 ASTM D2178 ASTM D4601 ASTM D4601 ASTM D4601 ASTM D4897 ASTM D4897 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164. ASTM D6163 Product Description Smooth surfaced asphaltic ply sheet reinforced with fiberglass mat. Smooth surfaced asphaltic ply sheet reinforce& with fiberglass •mat. • . • Smooth surfaced asphaltic ply sheet ilinforced • with fiberglass mat. . . . Smooth asphaltic base or base/ply skeet•reinforceed with fiberglass •mat. • •• ••• ••• ••• • Smooth asphaltic base or base/ply :lketr;inforced • with fiberglass mat. • • • . Smooth asphaltic base or base/ply suet rainforcec • • with fiberglass mat. • • Smooth surfaced asphaltic perforated venting base sheet reinforced with fiberglass mat. Smooth surfaced asphaltic nailable venting base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. SBS polymer -modified asphalt base or anchor sheet reinforced with a fiberglass mat. Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. i (MIAMI•DADE COUNTY) NGA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 ortv ,,F a7 T 7 .a OF PRODUCTS t i t TI6 MANUFACTUREDLABELED fait I{U C�1_lAs PL_IaCANT`. TRADE �"IF'`..1`%II,�S Ii_f l`•�I�11F`_ �iPL OR JEt. 1f�_JJ.1. IIiBLE1 Product Ruberoid® HW Smooth GAFGLAS® Mineral Surfaced Cap Sheet Tri-Ply® BUR Granule Cap Sheet • GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet Topcoat' Surface Seal SB Topcoat® Membrane Dimensions 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 5 or 55 gallons 1, 5 or 55 gallons Topcoat® MB Plus 5 or 55 gallons Topcoat® FireOut." 5 or 55 gallons Fire Barrier Coating VersaShield®Fire- 12" x 100' rolls Resistant Roof Deck Protection VersaShield® Solo' 42" roll wide, 100 Fire -Resistant Slip ft. Sheet Topcoat® FlexSear 1, 5 gallons or 1 qt. tube Test Specification ASTM D6164 ASTM D3909 ASTM D3909 ASTM D3909 ASTM D 6083 ASTM D6083 Proprietary Proprietary Product D escriptiorr Smooth surfaced torch applied SBS base or anchor sheet reinforced with a polyester mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Cap sheet is factory coated with TOPCOAT® EnergyCoteT"` Elastomeric • • Coating. •• • • . • •• . • • Solvent -based thermoplastic rubbor•: • • • sealant designed to protect and restvrc teed roof surfaces and to increase roof refl4G1Mty. • .••• Water -based elastomeric coating • • .. •• • •.. •. • •• • • Water based, low VOC primer designed Zo block • • •• • . • •.• Low VOC, water based fire barrier coating. asphalt bleed -through. • • • • . • • .. ASTM D226 Non -asphaltic, fiberglass reinforced underlayment and/or fire barrier ASTM D146, D828, D4869, D6757 TAS 139 Non -asphaltic, fire resistant fiberglass underlaymeit Solvent -based elastomeric sealant. (MIAM!•DADE COUNTY) ) _ NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 ?nap all APPROVED .[lySlllLA II IIONS Product Name EnergyGuardT" Polyiso Insulation EnergyGuardT" Tapered Polyiso Insulation EnergyGuardTM Ultra Polyiso Insulation EnergyGuardT"' RA Polyiso Insulation EnergyGuardTM RA Composite Polyiso Insulation EnergyGuardT` RH Polyiso Insulation EnergyGuardT" RH Tapered Polyiso Insulation EnergyGuardTM RN Polyiso Insulation EnergyGuardTM Perlite Roof Insulation EnergyGUardTM Perlite Recover Board Securock® Gypsum -Fiber Roof Board Securock® Glass -Mat Roof Board Strnctodele High Density Fiber High density fiberboard Board Roof Insulation DensDeck® Prime Roof Board Gypsum board 1 is I;�LE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Glass -faced polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or perrnalite Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board Perlite recover board Gypsum board Glass faced gypsum board DensDeck® Roof Board Gypsum board RManufactu r'er (With Current NOA) GAF • GAF GAF GAF GAF . . . dliF• J • . • . . ... . • . trAF'� .. • • • . • • . • AF+.•• .. • • • •• GAF United States Gypsum Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC M1AMWAD ECOUN i NOA No.: 14-1030.0i Expiration Date: 11/04/18 Approval Date: 05/04/17 n op.. 4 of 31 APPROVED fSiEE _v e Fastener Number Product Name n, 1. Drill-Tec #12 Fastener 2. Drill -Tee #14 Fastener 3. Drill-Tec'" ASAP 3S 4. Drill-Tec"' 3" Steel Plate 5. Drill -Tee 3" Standard Steel Plate 6. Drill-TeC'3' AccuTrac®Flat Plate 7. Drill-Tec AccuTrac® Recessed Plate 8. Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) TABLE 3 Product Descriiotion Phillips head, modified buttress thread, pinch point, carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. Truss head, self -drilling, pinch point, high thread fastener for use in steel, wood or concrete decks. Drill-TecT" #12 Fastener with Drill -Tee 3" Standard Steel Plate. Round Galvalume® steel stress plate with reinforcing ribs and recessed for use with Drill-Tec'"` fasteners. Galvalume® coated steel stress plate for use with approved Drill-TecTe fasteners. A2-SS aluminized steel plate for use with Drill -Tee fasteners. Galvalume® steel plate with recess for use with Drill- TecTM fasteners. Round Galvalume® plated steel stress plate with reinforcing ribs for use with Drill -Tee fasteners. Dimensions #12 x 8" max. length, #3 Phillips head. #14x 16" max. length, #3 Phillips head. See components 3" Round 3" Round 3" square; .017" thick 3" square; .017" thick 3" Round Manufacturer With. Current NQ'A GAF GAF • • • • ..•• • • ...RAF • • .• .• • • . • • • CAF • • • •.. • • • •• • • • . •• • GAF GAF GAF ••• • •. .• IAME•DADE COUNTY —�iMorM JJ NGA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 5 of 31 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. UL LLC PRI Construction Materials Technologies, LLC Test Identifier 3014547 3029832 3033135 3034312 3036980 3038278 3040738 3041769 3042887 3042905 3046081 3047636 ODOA8.AM OD 1A8.AM 0Y9Q5.AM 1B9A8.AM 2B8A4.AM 3B9Q1.AM 3D4Q2.AM 797-03221-267 797-03 825-267 797-10228-267 R1306 GAF-012-02-02 GAF-020-02-01 GAF-082-02-01 GAF-084-02-01 GAF-122-02-01 GAF-270-02-02 GAF-276-02-01Rev GAF-276-02-02 GAF-306-02-01 GAF-314-02-01 GAF-315-02-01 GAF-369-02-01 GAF-417-02-01 GAF-464-02-01 GAF-464-02-01 GAF-499-02-01 GAF-500-02-01 GAF-549-02-01 GAF-549-02-02 GAF-559-02-01 Description 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 UL 790 ASTM D4977 ASTM D4977 ASTM D6083 ASTM D6083 TAS 139 ASTM D226 ASTM D6083 ASTM D226 ASTM B96 ASTM D2178 ASTM D2178 ASTM C1289 ASTM C1289 ASTM C1289 ASTM C1289 ASTM D6083 ASTM D6083 TAS 114 TAS 114 TAS 117(B) • • • .. • Date 05/22/03 05/11/07 11/24/08 04/09/09 08/14/09 11/18/11 11/16/10 05/26/11 11/14/11 01/10/12 02/13/13 08/08/13 07/0; /99 • 07/21M4• • • 04/01/98 • • 09/04/97 07/02/97• 01/0/A8• • 05/30/.97•. • . • • • . • 09/2"7/4V• 07/21/08. • 01/2/W.:. • • • • • • •••• . • • • • • • : 04/04/6 : • •. 11/06/01 02/01/02 05/07/06 05/09/06 05/07/06 11/15/10 12/16/10 11/15/10 07/07/11 08/23/11 08/23/11 10/22/12 05/28/13 10/22/12 02/06/14 03/12/14 03/12/14 08/08/14 08/08/14 09/30/14 ((MIAMI-DADE COUNTY NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Pa2e6of31 EVIDENCE SUI M1)I T C� : Test Aeency ?RI Construction Materials Technologies, LLC IRT of S. Fl. Trinity I ERD Atlantic & Caribbean Roof Consultants, LLC ((CONTINUED) Test I perttffier GAF-559-02-04 GAF-559-02-05 GAF-559-02-06 GAF-559-02-07 GAF-559-02-08 GAF-559-02-09 GAF-559-02-11 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559-02-16 GAF-559-02-18 GAF-559-02-19 02-005 02-014 C8500SC.11.07 G30250.02.10-3-R2 G31360.03.10 G33470.01.11 G34140.04.11-2 G34140.04.11-4-R2 G34140.04.1.1-5-R3 G36780.07.11-R1 G40630.01.14-1 G40630.01.14-2A G40630.01.14-2A-1-R1 G43610.01.14 G6850.08.07-1 SC6870.08.14-R1 11-053 II eserliGtioo ASTM D 1876 ASTM D 1876 TAS 114(H) ASTM D 903 ASTM D 903 ASTM D 903 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 117 ASTM D3909 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6401 ASTM D4897 4470-TAS 114 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D3909 ASTM D3909 ASTM D3909 TAS 114 • • • • • • • •• • • • •• • Date 10/01/14 10/15/14 10/02/14 10/02/14 10/02/14 10/02/14 10/14/14- 10/14/14 10/15/14 10/15/14 10/15/14 10/15/14 10/11/.4.:. • 04/16/15 • • • . 01/1 a/02 03/22/02' •••• • • 11 /3 C/07 • 06/03125 • 03/31/Md • • • :11/16/11 • • 04/257rr ••• 06/04u1•5 • 06/04/15 • • 07/18/11 01/06/14 01/07/14 04/10/14 01/22/14 08/13/07 09/04/14 • • • •• 08/12/11 ( (MIAMI•DADE COON NOA 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Fire Barrier : (optional) Anchor sheet: Fastening Option #1: Fastening Option #2: Fastening Option #3: Fastening Option #4: Fastening Option #5: Ply Sheet: 1 [embra;te Type: Deck Type 11: Deck Description: System Type E(3): BUR Wood, Non Insulated Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. Anchor sheet mechanically attached to roof deck. All General and_ System Limitations shall apply. TOPCOAT FireOuf Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or VersaShield° Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. GAFGLAS® #75 Base Sheet, Tri-Ply° #75 Base Sheet, Ruberoid° 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/4 . •;. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheetside lapsand 8 •• • • • in. o.c. in the field of the sheet in two staggered rows. • (Maximum Design Pressure: —45 psf See General Limitation #7) • Miarni-Dade County Approved rein. 12 ga. annular ring shank nails arid'rh4n. 1-5/8:iir• •: • diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. • • •• • • ••• •• •• • (Maximum Design Pressure:—52.5psf See General Limitation #7) • • • • Drill-TecTm #14 Fasteners and Drill -Teo" 3 in. Standard Steel Plates, trill-feCTM AccuTrac° Flat Plates or Drill -Teo' 3 in. Ribbed Galvalume Plate (Fre space . l6 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet: in two staggered rows. (Maximum Design Pressure: —52.5 psf See General Limitation #7) Drill-TecT"` #14 Fasteners and Drill -Teo' 3 in. Standard Steel Plates, Drill -Tee' AccuTrac® Flat Plates or Drill-TecT°' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side Laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum .Design Pressure: —60 psf. See General Limitation #7) Drill-TecT' #14 Fasteners and Drill -Teo" 3 in. Standard Steel Plates, Drill -Teo' AccuTrac® Flat Plates or Drill -Teo' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum .Design Pressure:—97.5psf. See General Limitation #7) When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply'® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. When optional cap sheet is not present: Three or more plies of GAFGLAS° Ply 4, Tri-P1y® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. MiAM9•DADE COUNTY) N O A No.: 14 -10 3 0.01 Expiration Date: 11/04/18 i nn rnvap UTIntp! (DSI414I17 Cap Shee9: ,ct SzrFscatFSlg: 2, (Optional) GAFGLAS® Mineral Surfaced Cap Sheet, Tri Ply° BUR Granule Cap Sheet or GAFGLAS EnergyCapt Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instr ctions. Optional on granular surfaced membranes; required For smooth membranes. Chosen components must be applied according to manufacturer's application instructions.. All coatings :must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. Topcoat° Membrane or Topcoat° Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat° 1vIB Plus applied at 0.5 to 0.75 gal.Isq.(to be used as a primer) followed by Topcoat° Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Above. . . . . . .. . . • .... . . . . • • . • . • • • • • • • • • •• • . . • • . • •• . • • • • • • • .. • • • •.• . • • (MIAMI•DADE COUNTY) \) NOA No.: 't 4_1030.01 E xpj ation Date: g1/04/18 Approval Date: 05/04_/17 WOOD DECK SYSTEM LIMITATIONS: ONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLASi° Flex P1yTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/a" DensDeck' Roof Board or %a" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITA T IONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed .ell foam insuiatir_i%• when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot. • • • mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in tj azvs, onl jai' • • • each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Becialling of the • • • strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventjlatioii.. Asph:Lt..;. • application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached syssernl shall re .. • • limited to a maximum design pressure of -45 psf. ••c • • •• 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') val .21S lbf., as •• • • tested in. compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below . 275 lbf. insulation attachment shall not be acceptable. • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on•a minitSitrr ; • • fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation 47 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF TIES ACCEPTANCE ANCE r(MIAMI•DADE COUNTY)) IIA, t ,7 \II NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 r • 10/25/2017 TGFU.R1306 - Roofing Systems ':b i4i€,9f<OERTiF€G.4.710 14 ; �tsFirrORV Page Bottom See General Information for Roofing Systems GAF 1 CAMPUS DR PARSIPPANY, NJ 07054 USA Roar! cl Systems. 6ROI;fing Systems R1306 "RUBEROID® 20 Smooth" or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" may be utilized as an alternate to Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UItimaTM Base Sheet" base sheets in any of the following Classifications. 1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or 1/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt pints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® r 8rliT" Roofboard" are to offset a minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the rgof s' tgm, it Must be placed below the overlayment board. 1/4-in. thick (minimum) "SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass-Mal,Roof•3oard" •• (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible deck in a system with any glLCA,siified iritul*eitr except polystyrene. • • • • Multiple plies of Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra-Flgxibl•P1y 6" m:y In Nhered to • Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGusndi"L Roofboard" in hot roofing • • • • asphalt. • • • • • • .••••. . •.••.•• "GAFGLAS® FIexPIyT" 6 5L" and "GAFGLAS® FIexPIyT" 6" may be used interchangeably in any roof covering system ITsted below. • ••• • "EnergyGuardTM Ultra" is an acceptable alternate to "EnergyGuardT"" in any applicable Classification. •• • •• • • • • "GAFGLAS® Stratavent® Nailable Venting Base Sheet" may be mechanically fastened or fully adhered with hot.roofyne•asphali over noncombustible decks and as a recover over existing roof systems. • • • • • • • •• • • 'EnergyGuardTM Perlite Insulation" may be utilized as a cover board over "EnergyGuardT"" in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, fully adhered with hot roofing asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications include insulation. Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation instructions (excluding "LRF Adhesive 0") in any applicable Non -Combustible Roof Deck Classifications. "EnergyGuardTM Tapered" is an acceptable alternate to "EnergyGuardT"" in any applicable Classification. "EnergyGuardT" Ultra Tapered" is an acceptable alternate to "EnergyGuardT" Ultra" in any applicable Classification. "EnergyGuardT" NH Tapered" is an acceptable alternate to "EnergyGuardT" NH" in any applicable Classification. "EnergyGuardT" NH Ultra Tapered" is an acceptable alternate to "EnergyGuardT" NH Ultra" in any applicable Classification. "EnergyGuardT" Barrier Tapered" is an acceptable alternate to "EnergyGuardT" Barrier". "EnergyGuardT" NH Barrier Tapered" is an acceptable alternate to 'EnergyGuardTM NH Barrier". Minimum 1-in. thick "EnergyGuardT" Barrier" is an acceptable alternate to "EnergyGuardT" Ultra" in any applicable Classification. Minimum 1-in. thick "EnergyGuardTM NH Barrier" is an acceptable alternate to 'EnergyGuardTM NH Ultra" in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ('GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one.ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet") may be substituted for Type G1 asphalt glass fiber ply sheet ^--<__.1/dq 10/25/2.017 TGFU.R1306 - Roofing Systems ("GAFGLAS® Ply 4" or "Tri-Ply® PIy 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS® Flashing" or "RUBEROID®" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes any UL Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS® #80 UItimaTM Base Sheet" may be used in any of the following systems. "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United Coatings" FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2. Class A, B and C • Hot roofing asphalt, for use with glass felts or modified bitumen membranes. • • • • • • "RUBEROID® Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROID® Mop" SBS roofing membranes in anyapgo sable Classification. • • Class A 1. Deck: C-15/32 Incline: 3 •••• • • • • • • • • •• • • • • • • • • ••• • • • • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC' eMIDeck® Rd'oTboatd" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick Uniteel•6teti s Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • • • • Vapor Barrier: — one or more plies "GAF® SA Vapor Retarder" self -adhered • • • • • Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane err parliie/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thicftiess.' • • • • PIy Sheet: — Three or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-PIy® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® UTtta-Flexible Ply 6", fully adhered with hoot roofing asphalt. Surfacing: — Gravel. • • •• • 2. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.. PIy Sheet: — Three or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-PIy® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible PIy 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 3. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, 2-in. maximum. PIy Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-PIy® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT" Min.eral:Su.r..fa.oed Cap Sheet", fully adhered with hot roofing asphalt. 3 4. Deck: C-15/32 Incline: 1 SITpVSheet (Optional): — Red rosin paper, nailed to deck, Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75. E3ase Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet" or "GAFGLAS® Stratavent® Nailabie Venting Base Sheet", mechanically fastened. 1 %'/25/231. TGFU.R1306 - Roofing Systems • '/ s c%''ry'Sheet: - One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or GAFGLAS® Flex Ply 6" or "Tri-PIy® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet:.— Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap"'^ Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. Coating (Optional): "United CoatingsT" TOPCOAT® EnergyCoteTM Roof Coating" or "TOPCOAT® MB Plus Coating" or "United Coatingsm` Roof Mate MB Plus Coating" applied at a rate of 2-gal./100-ft.2. 5, Deck: NC Incline: 3 Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. PIy Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap"" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 6. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation: — One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or phenolic, 1-in. minimum (offset a minimum of 6-in. from plywood deck joints). Base Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-PIy® Ply 4" or "GAFGLAS® PIy Flex 6" or "Tri-PIy® Ultra -Flexible Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-PIy® #75 Base Sheet" or "GAFGLAS® #80 Ultima'm Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-Ply® APP Smooth" or "RUBEROID® Torch Granule"+or "RUBEROID® Torch 180" or "Tri-PIy® APP Granule", torch applied or "RUBEROID® Mop Smooth" or "LUBEF;OID® 14051iiooth 1.5444••• "RUBEROID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-PIy® SBS Sranele•fully a 1hereci with hot •• roofing asphalt. •• • • Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet'•d :"GAFGLAS® EnergyCae Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • • • 7. Deck: C-15/32 Incline: 2 • • • • • • • • • • • • • • • • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "aensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick Unifet States Gypsum Co. • ® "SECUROCKRoof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • `• • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or• • perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate comPDsite car Pheno 'an; thickness. Base Sheet: — Two or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-PIy® #75 Base Shee!" oreG:4FGLASA Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type 4(.1:13 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. PIy Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-PIy® Ply 4" or "GAFGLAS® Ply Flex 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-Ply® APP Smooth" or "RUBEROID® Torch Granule" or "RUBEROID® Torch 180" or "Tri-PIy® APP Granule", torch applied or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SBS Granule" fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 8. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened, any thickness. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. PIy Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet", fully adhered with hot roofing asphalt. • Coating: — "United Coatings'1 FireShield MB Roof Coating" applied at a rate of 2-1/2.to 3-gal./100-ft.2. • 9. Deck: C-15/32 Incline: 1 Barrier Board (Optional) — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardt" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane: or perlite/polyisocyanurate composite or perlite/urethane composite or wood-fiber/polyisocyanurate compositeor phenolic, any thickness. SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be ren fled in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). • . .. . 4. Exposed Ceiling: Exposed, open beam ceilings are where the undetsld0rthe rood decking ca be iewed from below. The owner may wish to maintain the architectural app2drn&Sc'es, therefore, roofing nail penetration of the underside of the decking may not be acceptable. ThisYrNkles the eitlbtbf maintaining the appearance. •• • .• • • . . .... • • . ••• • • S. %/`-7 Overflow scuppers (wall outlets): It is required that rainwater flows dff seat the rizitig. not overloaded from a buildup of water. Perimeter/edge wall or other roof extension.maxbLock this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary tositstall overfM . scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. • • Owner/Agent's Signature Date Contor Signature Date Jl%•J Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number tam! =:s hores illage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 { / RE: Permit # Q — it - I —I'2-% O DATE: INSPECTION AFFIDAVIT (Print name and drele license Type) License #: C CC 132. On or about licensed as a (n) Contractor / Engineer/ Architect, FS 468 Building Inspector , I did personally inspect the roof deck nailing ,kk (Date & time) work at a l' E- Q_ .. +'�f'f I'l t � �- (r 'k1 L'' I2. ' � ) (Complete Joh Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 663.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she Is the contractor for the above property mentioned. Sworn to and subscribed before me this . day of Notary Public, Sate of Florida at Large 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an Inspection. include photographs of each plane of the roof watt permlt # and address di clearly shown marked on the deck br each inspection no,aoell AA r7lanMntairn1 »nnn