RF-17-2023Miami Shores Village
10050 N.E. 2nd Avenue NW
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
Pe
•m it
Issue Date: 8/10/2017
PerMit NO. RF-8-17-2023
Permit Type: Roof
Work Classification: Tile/Fiat
Permit Status: APPLIED
Expiration: 02/06/2018
Parcel Number
Applicant
69 NW 99 Street
Miami Shores, FL 33150-
1131010180490
Block: Lot:
LISA RABAH
Owner Information
Address
Phone
Cell
LISA RABAH
69 NW 99
MIAMI SHORES FL 33150-
69 NW 99
MIAMI SHORES FL 33150-
Contractor(s) Phone
PR-ESTO ROOFING CORPORATION
CeII Phone
Type of Work: Re Roof
Additional Info: RE -ROOFING FLAT& TILE
Classification: Residential
Scanning: 3
Fees Due
Bond Type - Contractors Bond
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee - New Roof
Scanning Fee
Technology Fee
Total:
Amount
$500.00
$7.80
$4.13
$4.13
$2.60
$275.00
$9.00
$10.40
$813.06
Pay Date
Invoice #
08/10/2017
08/10/2017
Bond #: 3481
Pay Type
RF-8-17-64831
Credit Card
Check #: 2794
Amt Paid Amt Due
$ 50.00 $ 763.06
$ 763.06 $ 0.00
Available Inspections:
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Roof in Progress
Renailing Affidavit
Review Roof
Cap Sheet
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUCHANIC WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: ify tha or= •oing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonze the above -named contractor to do the work stated.
August 10, 2017
Authorized Si••:ture:OwTr / Applicant / Contractor / Agent
Date
Building Department Copy
August 10, 2017
1
BUILDING
PERMIT APPLICATION
❑BUILDING ELECTRIC
❑PLUMBING ❑ MECHANICAL
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
gROOFING
PUBLIC WORKS
Master Permit No.
Sub Permit No.
RE C VIED
AUG 10 2017
FBC 20 Iq- S-h
6))F 11-2.0Z3
❑ REVISION ❑ EXTENSION ❑ RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: f'7 ki Id qq 71
LJ
City: Miami Shores /� County!�I . Miami Dade Zip: 3' / rO
Folio/Parcel#: //— 3/0 /- ?I?3 " d 44'0 Is the Building Historically Designated: Yes NO
Occupancy Type: li Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee' I
Simple Titleholder): Li54 r-E�/ .
O F4. Li* 4660 Phone#: ' .S 7'f2 " DJ z
/ Address: 4 MO q% 6 /
City: 7 i(41 1 .11t9i2,S
Tenant/Lessee Name:
State:
Email:'140. 5 5 /4IIOO.
Can
CONTRACTOR: Company Name: /(> G CoRP
Address: 7'6-o £(.J e6 I)
City:
Qualifier Name:
}
State:
tro I1. 2 i ,r!o
Phone#:
Zip: 3/ S O
Phone#: -?12 -1047
?At,-554--O3 .9 virv4
6
Zip: 33-0/^ _,
Phone#: W- >44-1fc
State Certification or Registration #: O S6 4.1 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: � City: State: Zip:
Value of Work for this Permit: $
Type of Work: ❑ A. • ition
Description of Work: `'
Zoql 7 7 Square/Linear Foot of Work:
n
Iteration
C
❑ New,
�1 a� t
•
'�w,tr�r..rfs;ro •:ex. * ,rn+. .:*,a•..x»..:c tj^. yx, •,w•...:..r
Specify color of color thru tile:
Submittal Fee $ —'0 i1 c (J Permit Fee $ � 15 CCF $ 7 . 80
Scanning Fee $ L Radon Fee $ I • 3 DBPR $ • )
Technology Fee $ to e 4 o
Structural Reviews $
CO/CC $
Notary $
Training/Education Fee $ Z • b Q Double Fee $
Bond $ `--�O0 ,-fz—
TOTAL FEE NOW DUE $
3; 04
(Revised02/24/2014)
/ G 0-6
Bonding Company's Name (if applicable)
Bonding Company's Address
• t.
City ` j State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City r S f State Zip
Application is hereby made to `obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO'RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR, PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT." , ,r ,
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faiththat a copy of the notice of commencement and construction lien lav/ brochure, will be delivered to the person'
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
"
OWNER or AGENT
- ._ .. • .
The foregoing instru ntwas ackno ledged beforerme this The foregoing instru was acknow ged before me this
2
/ ddlay��of/� 20 / 1 by day of �� 20 /7 by
Z. 144 /` �►u{+� , who is personally known to u !`(rut is erg sonally known to
me or who has produced as me who has produced as
identification and who did take an oath.
I CARLOS G. MENZEL
Sign:
Print:
Seal:
.% any Public - State of Florida
11:4" Commission # FF 126292
*****************************
APPROVED BY-_
,r
identification and who did take an oath.
NOTARY
Sign:
Print:
Seal:
` LIC:
0
irewid
CARLOS G. MENZEL
Plans Examiner
My Comm. Expires May 26..^018
Structural Review
(Revised02/24/2014)
a 1 ,
Banded Through National Notary Ass.
Zoning
Clerk
NOTAR IC:
GEOTECHNICAL I ENVIRONMENTAL I MATER1ALb Tt.aa+try rWac.a+vo i ...ova- i
FLORIDA BUILDING CODE TEST P
MIAMI, October 30, 2017
CLIENT: PRESTO ROOFIN ORP.: 8089 NW 67`h Street M. F
PROPERTY ADDRESS: Roo ` 69 N
DYNATECH ENGINEERING CORP.
WWW.DYNATECHENGINEERING.COM
CONCENTRATED UPLIFT LOAD TESTING ON ROOF T _
OCOL TAS-106
PERMIT No. RF-8-17-2023
IAMI SHORES, FL 33150
Y WITH
TILE TYPE/ATTACHMENT: Spanish S Roof Tile Polyfoam Set. Inspected By: DB
Testing Equipment: Humboldt Scale Model H-4620
The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample
dependent since roof condition are continuously changing due to the exposure to the element and roof top traffic. Client recognizes
that actual conditions in areas not tested by DEC may differ from those anticipated in DEC's report. Client understands and accepts
that this can significantly increase the cost of construction for its future projects. Client agrees that DEC shall not be responsible or
liable for any variations in the actual conditions of areas not tested by DEC.
Test No. Test Location Field Uplift Pull Test Test Result
1 - 34 Field See Sketch Below > Than 35 LBS Passed
35 - 41 Corner See Sketch Below > Than 35 LBS Passed
42 - 67 Perimeter See Sketch Below > Than 35 LBS Passed
62 - 79 Ridge Caps See Sketch Below > Than 35 LBS Passed
ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106
ROOF SKETCH
41
67
66
40 64 65 -..
39 1 62
63
61 i 2
42 43
29
28
30
23 24 25 ` 27
22 75 21 74
3 4
60 ' 1
77 11 76 10
59 1
12 13' 56
38i 58 137
Sincerely yours,
55
. v
20 73 19 7
5
9 8
14
,54
S '_--_�4'J--LQ! 36 j 201,)
WissanrNaamani, P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
15
53
44 35
32 45
33
69
31 46
47
26
70 .
18 48
L 49
16\
6
7 ' 50
9
52 51 \
Q
.rrr�Ir
9PAD N44
r°.�\�ENS��`:
N0. 39584-
k
•0 STATE OF .` w
NPO-
Page 1 of
750 WEST 84TH STREET. HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL :INFOODYNATECHENGINEERING.CON \ r
WI/J<
Local Business Tax Receipt
Miami -Dade County, State of Florida
-THIS IS NOT A BILL- DO NOT PAY
262469
BUSINESS NAME/LOCATION
PR ESTO ROOFING CORP
6089 NW 67 ST
MIAMI R. 33166
OWNER
PR ESTO ROOFING CORP
WOrker(s) 10
RECEIPT NO.
RENEWAL
262469
ILBT\
EXPIRES
SEPTEMBER 30, 2017
Must be displayed at place of business
Pursuant to County Code
Chapter 8A - Art. 9 & 10
SEC. TYPE OF BUSINESS
196 SPECIALTY BUILDING CONTRACTOR
CCC055561
PAYMENT RECEIVED
BY TAX COLLECTOR
$75.00 07/13/2016
CHECK21--16- 184538
This Local'Busiaess Tax Receipt only confirms payment of the Local Business Tax The Receipt is not a license,
penalty. acertification of the bolder's qualifications, to do business Holder must comply with any governmental
or nongovernmental regulatory laws and requirements which apply to the badness.
The RECEIPT N0. above mustbe displayed on all commercial vehicles - Miami -Dade Code Sec la-276.
Fur more information, visit yvww.mtamidade.00vitaxeoilector
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395
2601 BLAIR STONE ROAD
TALLAHASSEE FL. 32399-0783
ZUNINO, ADOLFO MARCELLO
PR-ESTO ROOFING CORPORATION
8089 NW 67TH STREET
MIAMI FL 33166
Congratulations! With this license you become one of the nearly
one million Floridians licensed by the Department of Business and
Professional Regulation, Our professionals and businesses range
from architects to yacht brokers, from boxers to barbeque
restaurants, and they keep Florida's economy strong.
Every day we work to improve the way we do business in order
to serve you better. For information about our services, please
log onto www.myflorldallcense.com. There you can find more
information about our divisions and the regulations that Impact
you, subscribe to department newsletters and leam more about
the Department's initiatives.
Our mission at the Department is: License Efficiently, Regulate
Fairly. We constantly strive to serve you better so that you can
serve your customers. Thank you for doing business in Florida,
and congratulations on your new license!
RICK SCOTT, GOVERNOR
LICENSE NUMBER
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND
PROFESSIONAL REGULATION
CCC055581 :ISSUED: 09/08/2016
CERTIFIED ROOFINGCONTRACTOR
ZUNIN0, ADOt„EQ MARCELLO;.
PR-ESTO ROOFING CORPORATION
IS CERTIFIED under the provisions of Ch.488 FS.
Expiration date : AUG 31, 2fl18 L1609080002939
DETACH HERE
KEN LAWSON, SECRETARY
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD
The ROOFING CONTRACTOR
Named below IS CERTIFIED
Under the provisions of Chapter 489 FS.
Expiration date: AUG 31, 2018
ZUNINO, ADOLFO MARCELLQ
PR-ESTO ROOFING CORPORATION
8089 NW 67TH STREET
MIAMI FL:4i166
Property Search Application - Miami -Dade County
http://www.miamidade.goy/propertysearch/#/report/summary
r OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3101-018-0490
Property Address:
69 NW 99 ST
Miami Shores, FL 33150-1740
Owner
LISA M RABAH
Mailing Address
69 NW 99 ST
MIAMI, FL 33150-1740
PA Primary Zone
0800 SGL FAMILY - 1701-1900 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
2 / 1 / 0
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
1,385 Sq.Ft
Lot Size
8,100 Sq.Ft
Year Built
1938
Assessment Information
Year
2017
2016
2015
Land Value
$178,398
$178,398
$131,771
Building Value
$96,396
$96,396
$97,199
XF Value
$361
$365
$370
Market Value
$275,155
$275,159
$229,340
Assessed Value
$178,414
$174,745
$173,531
Benefits Information
Benefit
Type
2017
2016
2015
Save Our Homes
Cap
Assessment
Reduction
$96,741
$100,414
$55,809
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
NAVARRO SUB PB 12-59
LOT 18 & W1/2 OF LOT 19
BLK 5
LOT SIZE 75.000 X 108
OR 19431-0529 12 2000 1
Generated On : 8/4/2017
Taxable Value Information
2017
2016
2015
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$128,414
$124,745
$123,531
School Board
Exemption Value
$25,000
$25,000 $25,000
Taxable Value
$153,414
$149,745} $148,531
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$128,414
$124,745
$123,531
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$128,414
$124,745
$123,531
Sales Information
Previous
Sale
Price
OR Book -
Pa 9e
Qualification Description
10/01/2007
$0
25964-1756
Sales which are disqualified as a
result of examination of the deed
03/01/2006
$385,000
24406-3616
Sales which are qualified
12/01/2000
$145,000
19431-0529
Sales which are qualified
03/01/1996
$66,500
17191-1770
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and
Mami-Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
1
Form YY
IN RE: THE MARRIAGE OF:
i/4-�t.1'4 /-�alca-1
Petitioner,
C-0
IN THE CIRCUIT COURT OF THE
ELEVENTH JUDICIAL CIRCUIT
IN AND FOR MIAMI-DADE COUNTY,
FLORIDA
FAMILY DIVISION
08 -0 4702 KO 1
CASE NO.: FC
FINAL JUDGMENT OF DISSOLUTION OF MARRIAGE (MSA)
THIS CAUSE a before the Court on this 2.e% day of KO cii
20 Oi on the ¥tA. ii/1 's Petition for Dissolution of Marriage. After
hearing argument of the parties, it is therefore,
ORDERED AND ADJUDGED that:
1. This Court has jurisdiction over the subject matter of this action.
2. This Court has jurisdiction over the parties:
A valid Florida Driver's License, ID or Voter's Registration Card has been
produced.
A Residency Witness Affidavit was submitted and made a part of the file.
There was sworn testimony as to 's
residency by who is qualified as a residency
witness.
Final Judgment of Dissolution 1
.A TRUE COPY
CERTIFIGA
CASE NO.: Oq � t °a FC'0
3. The marriage of the parties is irretrievably broken and is hereby dissolved.
4. There is/are t or minor child(ren) born of the marriage, to wit:
Name Date of Birth Sex
5. A marital settlement agreement has been executed by the parties. A copy of that
agreement is attached hereto. This agreement is ratified and is incorporated herein by
reference.
6. In accordance with the marital settlement agreement, the parties agree that there shall
be / parental responsibility and that the primary
residential parent shall be the
7. As agreed, the payor shall pay to the
the amount of $ f per as
and for child support pursuant to the statutory child support guidelines.
8. The Wife's former name is restored to ,. j 5 A M \ 1. A.,RELLA NU
9. This court reserves jurisdiction as to the welfare and best interest
10. This Court reserves jurisdiction for purposes of enforc
Final Judgment.
Petitioner Name:
Street Address:
City, State, Zip:
Telephone No.:
a iami-Dad o Fl• da this
RT JUDGE
BERTO It PINEIRO
N A D lM ,/� (� a N CIRCUIT COURT JUDGE
sgS CRAwo Cnucnft(?S'E
74/4m4 5cta�r_5 r_t„ 331)
Respondent Name: L-` -t 4 P T LL,6, ND fP Q R A n
Street Address: ‘y' /VW q'r $ T •
City, State, Zip: Mt t M l r . 37 15T,)TE OF FLOR
Telephone No.: htkcliy CERTIFY that the
Final Judgment of Dissolution
,rigirtel an file in this offi
-IARVEY RUVIN, Clerk
A, COUNTY OF DADE
ig411 rect copy of the
`t �UU AD 20
of Circ •linty Courts
2 Deputy Cie
3
Signature
State of Florida
County of Dade
Miami Shores Vivage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: 1"/11 L de) Li
Property Address: 6f A110 9g T
Date:
Roofing Permit Number:
Dear/ Building Official:
certify that I am not required to retrofit the roof to wall connections of my
build] g because:
he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
Z /,S Q _ -e/,/
C
Print Name
The undersigned, being the first duly sworn, deposes and says that he
Sworn to and subscribed before me this day of
J� t�
Notary Public, Sate of Florida at Large
e is the owner for the above property mentioned.
ARLOS�},rA0F�J2E�
,ro � Notary Pdblic - ate o Florida
My Comm. Expires May 26, 2018'
Commission # FF 126292
„'' Boded Through National Nte Assn
• When the just valuation of the structure for purpose of ad valorem taxation is equal ! r more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
- Zo
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application
oti •
'O Section A (General Information)
Master Permit No. Process No.
- TO Fit;;OF-c,Al-
INT
Contractor's Name
Job Address C l gq
Low Slope
0 Asphaltic Shingles
0 New roof 0 Repair
Low Slope Roof Area (SF) a614
ROOF CATEGORY
❑ Mechanically Fastened Tile X Morta Adl e vT ii= e Setss•
O Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
ROOF TYPE
. .
.. ..
• ▪ ' ..
.. .
0000
0000
.. .
. . .
.. .
0 Wood lirngies/ hS a• a s
0000
▪ 01100
•
• . .
0 Maintenance Reroofing • 0 RetUe41
• • .
ROOF SYSTEM INFORMATION • • •
Steep Sloped Roof AREA (SSF) l"(' Total (SF) r 7br� •
1
1
1
1
....1.
.F
• 1.
.....
,
....,
4.
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
q`
10--f
L
24
1
m!
t
rz
vJ
I.
p
!
f
10
•7-4
-,4f'
I
�-:,
t
,
}},�
.. ,' r
; '
f
I
FiI
�YW
nrr1
�.L 1f
-
z
'
'
�---► 9
LL_L
Q
N
t�xl0a l�o 4•3xz4 _ /032
ifs x13= 24 `f 5Ig lox (6 16D 1432. IF
_ l
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) ��� 10 ��� 15.37
ERNATIONAL CODE COUNCIL Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
1
1
1
1
1
1
1
1
1
1
—
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW:_ _ _ _ •
Roof System
Required Sections of the
Permit Application Form
Attachments Required .
See List I41'ft i •
Low Slope Application
A,B,C
1,2,3,4,5,p•7. • •
Prescriptive BUR-RAS 150
A,B,C
4,5,6 T • • • ••
Asphaltic Shingles
A,B,D
1,2,4,546,7•.• •
1,2,3,4,6,6*t • -
Concrete Clay Tile
A,B,D,E
Metal Roofs
A,B,D
1,2,3,4,5,6,7 •
Wood Shingles and Shakes
A,B,D
.
1,2,4,5%Z'; .
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
• •
••
• • •
•
•
••-
•
•••
•
-
- •
• •
• •
•
•
• •
• •
15.36
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section C (Low Slope Application)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer. 'f tE'�
Product Approval No.: - tf22 z/i r 4
Design Wind Pressures, From RAS 128 or Calculations:
P1: - L/2 P2: -% /., P3: -. %biS D
Max. Design Pressure, from the specific product
approval system: _ 52. 5
Deck:
Type: (000
Gauge/Thickness: Sig
"
Slope:
Anchor/Base Sheet & No. of Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insulation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet �Fa/ ever/ ondin�M�'aLLte`rial:,�p
III `l PIf (Y�9��'`�
Ply Sheet(s) & No. of Ply(s): i f ✓ ("2
Ply SheetFas
r/ndir,_•, aterial:
Top Ply: 41141-4,14A-- CM) 4zjta
k.
Top Ply Fitte er/ o di g erial:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Field: 4' " oc @ Lap, # Rows @ " oc ..
•
Perimeter: " oc @ Lap, # Roves• "pF
•..
.•Corner: " oc @ Lap, # Rows 14�• a . S " •
oc
•
Number of Fasteners Per Insulatiop•goard: V 44:.
.••.
Field Perimeter . . Corner •' •.
•. .. ...•
Illustrate Components Noted and RdgOs Applicablb:
Woodblocking, Gutter, Edge Term fiation'StripptrigMghing,
Continuous Cleat, Cant Strip, Base Flashing, Coenterflashing,
Coping, Etc. •..• • • ... .
Indicate: Mean Roof Height, Parapet Height, Height of:Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
tkao tfr
1
1
1
1
1
1
.r ....
1 •.
r•••
1 ••
.1.... •
1611L
Parapet
Height
/D
1
1
1
1
1
1
1
1
1
I
1
1
1
1
1
1
1
1
.
15.38
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer:
Notice of Acceptance Number: ib
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
P1: P1: P1:
Deck Type:
Ridge Ventilation?
¼(1()cv %1 i
Type Underlayment:
Insulation:
• •
• • •
•• •
•.•..•
•
••••
• •
.••.
0400
•• •
• • •
•• •
•
•
•• ••
•
•
• • • •
•
• • • •
• • •
•
• •
Fire Barrier:
Mean Roof Height: 1 7
Fastener Type & Spacing:
Adhesive Type:
• •
• • •
Ai
•
•
Type Cap Sheet.
Roof Covering:
Type & Size Drip
Edge:
• 1 •
•1•••
•1•••
1 •
•
•
• 1 • •
1
1
1
1
1
1
1
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
INTERNATIONAL CODE COUNCIL
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations. Adddtione!!Y, the
following items should be addressed as part of the agreement between the owner ant :le cSmtractor. Pt *Owner's •
initial in the designated space indicates that the item has been explained. •• • ••• •• • •
•
•
. • .
g4igefdeckjrtartf eto •
-� Renailing •wood decks: When replacing roofing, the existingwG
be renailed in accordance with the current provisions of Section R4403. (The caofdegk is u snail)i.�
concealed prior to removing the existing roof system). ..• .. ....
.
• •. •
• •
•
• •
•
•.
y 4. 2') u Exposed Ceiling: Exposed, open beam ceilings are where the uDdere(de of the3 roof decking'
can be viewed from below. The owner may wish to maintain the architectural appearance; ttierefo�a�
roofing nail penetration'of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
A., 6. l/� Overflow scuppers (wall outlets): it is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and R4413.
d 4Pl/ Wr7
Owner/Agent ignatur 'bate
Property Address
Revised on 7/9/2009 0:07/01/2015;
Permit Number
•
•
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.2ov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Plodugt Contret kition to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisd%.tidal {AHJ). . . •
•
' . • . .
•
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County ct Control Section,
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve t1 sight to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in tie accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediate/ Yetoke, rpheltf'6 or
•
suspend the use of such product or material within their jurisdiction. RER reserves the righ't'to'revoke thi's'fc'ceptande, .
•
if it is determined by Miami -Dade County Product Control Section that this product or material �`r1s to meet the •
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the F18txda £iuilding.Code
including the High Velocity Hurricane Zone of the Florida Building Code. '.:
DESCRIPTION: Polyglass Polystick Underlayments
.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.,
MIAMI DADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category:
Sub -Category:
Material:
Roofing
Underlayment
SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick IR-Xe
Manufacturing
Location #1 & #2
Polystick Dual Pro
Manufacturing
Location #2
Polystick Tile Pro
Manufacturing
Location #2
Polystick TU Max
Manufacturing
Location #1 & #2
Polystick TU P
Manufacturing
Location #2
Polystick TU Plus
(Surface Printing)
Manufacturing
Location #1 & #2
Polystick MTS
Manufacturing
Location #2
Polystick MTS Plus
Manufacturing
Location #2
Elastoflex S6 G
Manufacturing
Location #2
MIAMI.DADE COUNTY
APPROVED
Dimensions
65' x 3'33/8"
Or65'x3'
60 mils thick
61' x 3'33/8"
60 mils thick
61' x 3'33/8"
60 mils thick
65'8" x 3'3-3/8"
60 mils thick
32'10" x 3'33/8"
130 mils thick
65' x 3'3 3/8"
80 mils thick
65'8" x 3'33/8"
60 mils thick
65'8" x 3'33/8"
60 mils thick
32'10"x3'33/g"
Test
Specification
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103
TAS 103
TAS 103 and
ASTM D 6164
Product
Description
A fine granular/sand top surface self -adhering, APP
polymer modified, fiberglass reinforced, bituminous
sheet material for use as an underlayment ih's1tped roof
assemblies. Designed as an i e .&• fain shieI : . •
• •
A rubberized asphalt self-adAM$,'glass-fMer7polyesttt • • • •
•
reinforced waterproofing membrane. Designed as a •
metal roofing and roof tile unirryment.. •
• •
A rubberized asphalt self-adheanpglass.freer7polyesfet"'
reinforced waterproofing membrane. Designecaas a metal •
•
roofing and roof tile underlarm2ht: •••
A rubberized asphalt self-adien g.polyes ter reinforced •• • •
•
waterproofing membrane. Designed as a a rcafl ile
underlayment.
A rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface
designed for use as a tile roof underlayment.
A rubberized asphalt self -adhering, glass-fiber/polyester
reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polyester reinforced, SBS modified bitumen membrane
with a sanded back face and a granule top surface. For
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
Test Azencv
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
EVIDENCE SUBMITTED
Test Identifier
P10870.09.08-R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
P40390.08.12-2
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC 10130.06.16-3
PLYG-10130.06.16-1
PUSA-035-02-01
PUSA-055-02-02
PUSA-089-02-01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
Test Name/Report
TAS 103
TAS 103/ASTM D4798 & G155
ASTM D1970
TAS 103
ASTM D 1623
TAS 103/ASTM D4798 & G155
TAS 110/ASTM D4798 &R?9'0
ASTM D 1623
ASTM D6164 •
TAS 103, TAS 110 & AST$ $ Q23
ASTM D 1623 • • •'
TAS 103 & TAS
ASTM D 1970 & TA
TAS 103 & TAS 1 ZO •
ASTM D 1970 & TAS 110.
• • •
•• •
TAS 103
TAS 103
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
Date
12/04/08
04/13/09
07/01/10
03/02/11
04/26/11
. "61/01 / 11
•••14/19/11 ••
07/02/ 13
;••Q5/12/14•
• 10/03/14
.•'110/07/14
to/17/14
• 0(/27/16
:1'48t27/16.
•
•
• n29/06
12/10/07
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI.DADE COUNTY
APPROVED
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
MIAMIDADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1:
Deck Description:
System Type E(1):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(2):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(3):
Anchor/Base Sheet:
Fastening:
Ply Sheet:
Membrane:
Surfacing:
MIAMI.DADE COUNTY
APPROVED
Wood, non -insulated
Min. 19/32" plywood or wood plank
Anchor sheet mechanically fastened to deck, membrane adhered
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
See General Limitations Below.
Wood, non -insulated
Min. 19/32" plywood or wood plank
• •
• . .
.. .
• • Anchor sheet mechanically fastened to deck, membrane adhered • • • •
One or more plies of ASTM D 226 Type II or ASTM D 2626. •. • •. •
••••
••••
•• •
• • •
•••
•
•
• •
•
••••
• •
•
•
•
•
•
• •
•
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for •.
base sheet only)
Elastoflex S6 G, hot asphalt applied
See General Limitations Below.
• • •
•• •
• •
••• •
• •
••
•
•
Wood, non -insulated
Min. 19/32" plywood or wood plank
Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Polystick TU Plus, self -adhered.
See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
•
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface:, givng speciaLattention
.. . .. .
to lap areas. • • • •
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assem if �ni: ent Pr& uct ContrMr"' •
•
Notice of Acceptance. •. • • ,
•
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The. a9hing tape's i fl be
pressed in place and formed around the protrusion to ensure a tight fit. A second la}ttlif''1 olystigk Shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
• • •
•
• . .
.. •
.
.
... .
..
•
•
•
. •
. .
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
MIAMI•DADE COUNTY
APPROVED
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Profile
Polystick
MTS
Elastoflex
S6 G
Polystick TU Plus,
TU P, Tile Pro,
Dual Pro
Polystick
TU Max
Polytticlj • •
MTS Pits •
•
Sy9tent (E3) • •
MIS %.la§ with
i0 Plus •'
Flat Tile
Prohibited
without battens
4:12
6:12
6:12
5:12 • • • •
••••
• 6:12 : •
• •
Profiled
Tile
Prohibited
without battens
4:12
6:12
6:12
4: r2: •':
•• ••
. • 1 !112 • •
•••• .•
•
••••
•
•
••••
..•.
•.•
• •
.••
•
•
The above slope limitations can be exceeded only by using battens in accordance with the Approvgd.T.ik Syste'hi • • • •
Notice of Acceptance and applicable Florida Building Code requirements. When batlensare required, the•y shall •. •
be utilized during loading and installation of tiles. • •
•
•
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
0
0.
0
0)
t0
POLYST1CKIU Plus
MIAMI•DADE COUNTY
APPROVED
(6 Max. Per Stack)
12
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
• • • •
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK.MEMB ES
•• •
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SWIM APPLICATIONS. •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMN U DATIONS : •
•
•
•
•
..•. • •
1. Polyglass does accept the direct application of Polystick underlayment membranes tq,wbprl•decks'.Iy4�Pllers ark • • • •
cautioned to refer to applicable local building codes prior to direct deck installation to.ansure this is acceptable. . •
• • • •
Please also refer to applicable Product Data Sheets of the corresponding products. • • • •
•
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edgg Se4m as i2v.Polyglass:
•
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal di%k*s
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
MIAMFDADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
•
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as btitli;ed by
the National Roofing •Contractors Association (NRCA). • •• •••• ""
•• • •• • •
••• • •
•••
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPEC1p?C APPLICATIONS. •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMTVI IVOATK3118.: • '
END OF THIS ACCEPTANCE
MANMADE COUNTY
APPROVED
•
• •
•• •• ••••
• •
•
• •• •
• • • • •
••• • • ••• • • •
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AN1) CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
CertainTeed Corporation
1400 Union Meeting Road, P.O. Box 1100
Blue Bell, PA 19422-0761
MIAVII-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
www.miamidade.gm/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER ' •
Product Control Section to be used in Miami Dade County and other areas where a11ow•ed bathe Authoitx•
Having Jurisdiction (AHJ).
• • •
•• • •• •
•
•
This NOA shall not be valid after the expiration date stated below. The Miami -Dade .Gdunty Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Mian>,i•9ade Count).
reserve the right to have this product or material tested for quality assurance purposes?f tkis product or .
material fails to perform in the accepted manner, the manufacturer will incur the experts dP t..tch tesdfig••
and the AHJ may immediately revoke, modify, or suspend the use of such product or maierial wiPrirr�•
their jurisdiction. RER reserves the right to revoke this acceptance, if it is determine:1 by. Miami -Dade•
County Product Control Section that this product or material fails to meet the requireglents of •tttt• •
applicable building code. • • • • • • • • •
• This product is approved as described herein, and has been designed to comply with the Florida Building • Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Conventional Built -Up -Roof Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 08-0410.07 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jorge L. Acebo.
MANMADE COUNTY
APPROVED
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 1 of 16
ROOFING SYSTEM APPROVAL
Category:
Sub -Category:
Material:
Deck Type:
Maximum Design Pressure:
Roofing
Built -Up Roofing
Fiberglass
Wood
-60 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
All Weather/Empire
Base Sheet
Flintglas® Mineral
Surfaced Cap Sheet
Flintglas® Mineral
Surfaced Cap CoolStar
Flintglas® Ply Sheet
Type IV or VI
Flex-I-Glas Base Sheet
Flex-I-Glas FR Base
Sheet
GlasBaseTM Base
Sheet
Black DiamondTM
Base Sheet
MIAMI•DADE COUNTY
APPROVED
Dimensions
36" x 65' 10";
Roll weight: 86 lbs.
(2 squares)
36" X 32' 10'';
Roll Weight: 78 lbs.
(1 square)
36" X 32'10";
Roll Weight: 78 lbs.
(1 square)
36" x 164'7";
Roll weight: 40/55
lbs.
(5 squares)
36" x 98'9";
Roll weight: 90 lbs.
(3 squares)
36" x 98'9":
Roll weight: 90 lbs.
(3 squares)
36" x 98'9":
Roll weight: 69 lbs.
(3 squares)
36" x 68'7"; Roll
weight: 78 lbs.
(2 squares)
Test
Specification
Product
Descri§tiop'.
.. •
.. .
. . .
ASTM D 4601 Asphalt coated, fibergl'dSS'Cdiflforcedbtst
•
Type II sheet.
•
UL Type 15
ASTM D 3909
ASTM D 3909
ASTM D 2178
Type IV or VI
UL Type G 1
ASTM D 4601
Type II
UL Type G2
ASTM D 6163
Grade S
Type I
ASTM D 4601
UL Type G2
. .
... •
....
Asphalt impregnated aotd cowed inorganic'
glass fiber surfaced wi:1T rririral granules
used as the top ply in conventional apijt Dp
roof membranes. • .. . ... .
Asphalt impregnated and coated inorgank•
glass fiber surfaced with mineral granules
used as the top ply in conventional built-up
roof membranes. Covered with reflective
CoolStar Coating.
Fiberglass, asphalt impregnated ply sheet.
SBS Modified, fiberglass reinforced base
sheet.
SBS Modified, fiberglass reinforced base
sheet.
Asphalt coated, fiberglass base sheet.
ASTM D 1970 Self -adhering fiberglass reinforced
modified bitumen base sheet
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 2 of 16
APPROVED INSULATIONS:
Product Name
FlintBoard ISO
ACFoam-II
High Density Wood Fiberboard
Perlite Insulation
H-Shield
DensDeck. DensDeck Prime
ENRGY 3. ENRGY 3 25 PSI
Multi-Max-3. Multi -Max FA-3
APPROVED FASTENERS:
Fastener
Number
Product
Name
I. Dekfast Fasteners #14 &
#15 HS
2. Dekfast Galvalume Steel
Hex Plate
3. Dekfast Dekflat Round
Plastic Lock Plate
4. # I2 Standard Roofgrip &
# 14 Roofgrip
5. AccuTrac Hextra
6. 3 in. Ribbed Galvalume
Plate
7. AccuTrac Plate
8. 3 in. Round Metal Plate
9. Trufast # 12 DPH &
Trufast # 14 HD Fastener
10. Trufast 3" Metal
Insulation Plate
MIAMI•DADE COUNTY
APPROVED
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Wood fiber insulation board
Perlite insulation board
Polyisocyanurate foam insulation
Water resistant gypsum board
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
TABLE 3
Product
Description
Insulation fastener
Galvalume AZ50 steel plate
Polypropylene plate
Insulation fastener for wood
and steel.
Insulation fastener for wood
and steel
Galvalume stress plate.
Galvalume stress plate.
Galvalume AZ50 steel plate
Insulation fastener for wood
and steel decks
Galvalume AZ50 steel plate
Manufacturer
(With Current NOA)
CertainTeed Corp.
Atlas Roofing Corporation
Generic
Generic
Hunter Panels, LLC
Georgia Pacific Gypsum.L,kC
Johns.Maville Corp • •
RMax {9p rating, Lto. • •
•
....
....
•
.. ..
. • ..
• • • •
Manufacturer •
Dimensions (W.ith Gurrent:IOW
• • •
SFS Intec, Inc • •
2 7/8" x 3 1/4"
3"x3'/4"
3" round
3" square
3" round
3" round
SFS Intec, Inc.
SFS Intec, Inc.
OMG, Inc.
OMG, Inc.
OMG, Inc.
OMG, Inc.
OMG, Inc.
Altenloh, Brinck & Co.
U.S., Inc.
Altenloh, Brinck & Co.
U.S., Inc.
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 3 of 16
EVIDENCE SUBMITTED:
Test Agency/Identifier
Trinity(ERD
Momentum Technologies, Inc.
Factory Mutual Research Corp.
Underwriters Laboratories, Inc.
United States Testing Company
PRI Construction Materials
Technologies LLC
MIAMI•DADE COUNTY
Name
TAS 117 (B)
TAS 117 (B)
TAS 117 (B)/ ASTM D6862
TAS 114
ASTM Physical Properties
ASTM D4601
ASTM D3909
ASTM D1970
ASTM D 4601
ASTM D 3909/ D 4897
FMRC 4470
FMRC 4454
FMRC 4470
FMRC 4470
UL 790
ASTM D 5147
ASTM D 5147
ASTM D2178
ASTM D2178
ASTM D6163
ASTM D4601
Report Date
3503.10.06 10/10/06
06490.04.07-R 1 06/27/07
C8500SC.11.07 11/30/07
C8370.08.08 08/19/08
C10080.09.08-R4 03/25/10
C40050.09.12-1 09/28/12
C44200.03.13 03/22/13
C40050.09.12-2 09/28/12
AX31G8D 09/05/08
AX31G8C • 09/05/018::•••
• • •
J.I. #3Y8A1.AM (73/23/9.8•.•.
J.I. 0D3A3.AM • 64/04/9'?'•'
J.I. 2DOAO.AM ....12/23/98 •
J.I. 1D7A4.AM '....1'1/09/fig••••
R11656 • 81/11/0••••
•• •• ••••
97457-4 • • 86/03/88 •
97-457-2R T 2/02/$3 • •: •
• •• ••
CTC-122-02-01 " C13/13/12•.
CTC-123-02-01 03/13/12 •'
CTC-066-02-01 08/09/11
CTC-127-02-01 03/13/12
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 4 of 16
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type E(2): Base sheet mechanically attached.
All General and System Limitations apply.
Base Sheet:
Fastening:
Ply Sheet:
Cap Sheet:
Surfacing:
All Weather/Empire Base Sheet, GlasBase base sheet or Flintglas Premium Ply
Sheet mechanically attached as detailed below.
Base sheet shall be lapped 4" and fastened with 1 I ga. annular ring shank nails and
approved tin caps 8"o.c. in the lap and three rows staggered in the center of the
sheet 8"o.c.
Two or more plies of Flintglas Ply Sheet (Type IV) or Flintglas:Predium PlyMit&
(Type VI) or ASTM D226, Type I sheet adhered in a full moppgii ol: pprov ece..'
•
asphalt at an application rate of 20-35 lbs./sq. ••
(Optional) One ply of Flintglas Mineral Surface cap sheet or FlYptJ s Mine: 1• •' • •
Surfaced Cap CoolStar adhered in a full mopping of approved aspllal>.at an .... • •
•
application rate of 20-35 lbs./sq. .. ..• ....
•
(Required if no cap sheet is used) Any coating, listed below, us d as a surfaein .
must be listed within a current NOA. Install one of the followiQg: • • • •
1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respecti/ely ill a floEtltsaC
of approved asphalt at 60 lb./sq. ' •
2. A two part coating consisting of a base coat of APOC #300 Asphalt Fibered
Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered
Aluminum Roof Coating.
Maximum Design
Pressure: -52.5 psf. (See General Limitation #7)
MIAMI.DADE COUNTY
APPROVED
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 14 of 16
•
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum. • • • •
4. An overlay and/or recovery board insulation panel is required on all applicatigins over clostil.W
foam insulations when the base sheet is fully mopped. If no recovery board is iisea tke base.sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles,,•r.o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center dP'thh'lheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. Al"lireak stalls ge
••
placed every 12' in each ribbon to allow cross ventilation. Asphalt application oo eeQ1er system s1 11 • •
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limjtatda matij ?
design pressure of -45 psf. • .'
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F) variue of •
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If:he dalue, • •
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. "'. • • .
•
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said
revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
•
•
•
NOA No.: 13-0204.14
Expiration Date: 06/19/18
Approval Date: 05/30/13
Page 16 of 16
• •
CERTAINTEED CORP R11656
ROOFING PRODUCTS GROUP 1400 UNION MEETING RD PO BOX 1100, BLUE BELL PA 19422USA
Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A, B or C
roof constructions indicated below.
Type G1 Flintglas Ply Sheet or Flintglas Premium Ply Sheet are suitable alternates for Type 15 organic
felt; Type G2 Glasbase Base She is a suitable alternate for Type 15 and Type 30 base sheets; Type G3
Flintf ai drlace Lap Sheet is a suitable alternate for Type 30 Cap Sheets. Flex-I-Glas, Premium
Flex-I-Glas or Flintlastic Base 20 Sheet is a suitable alternate for the G2 glass base and the Type 15 All-
Weather/Empire base sheet. •••••
•
Unless otherwise indicated, base sheets are mechanically fastened or spot mopped•in pltice; pearl& iap ••
sheets are hot mopped in place. •
Black Diamond base sheet is limited to noncombustible decks and combustible deckssiquiring;
insulation.
Two plies Type G1 may be utilized in place of one ply Type G2.
. .
.. ..
• . •
• •
Flintlastic Ultra Glass SA is a suitable alternate for Type G2 Glasbase Base Sheet. •• •
.•••
• •
.. • .
• •
••• •
••
"Black Diamond Base Sheet" is a suitable alternate for Type G2 Glass Base Sheet.
"Flintlastic SA NailBase" or "Flintlastic SA PlyBase" are suitable alternates for Type G2 base sheets in
Roofing Systems (TGFU) that limit cover applications to self -adhering ply/base sheets or membranes.
EPS insulation followed by 1/2 in. cover board may be utilized in any of the following systems.
The "YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible deck roof
systems and, where indicated, in combustible roof deck systems.
"Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA" .
APP Base T is a suitable alternate for any Type G2 base sheet.
"Flintlastic Ultra Poly SMS" may be used in lieu of "Poly SMS Base" in all application Classifications.
References to Type G2 base sheets includes "Channel -Vent GB".
"FlintBoard Iso", "FlintBoard Iso Cold", "FlintBoard Iso-T" or "FlintBoard Iso Plus", may be used wherever
polyisocyanurate insulation is specified.
Uniform thickness or tapered insulation may be used in the following systems provided they do not
exceed the indicated incline or thickness.
•
• •
"Base Sheet: One layer Type G2 "Glasbase Base Sheet" .
C Ply Sheets: Two layers Type G1 "Flintglas Ply Sheet"
Cap Sheet: One layer Type G3 "Flintglas Cap Sheet" . i
9. Deck: NC Incline: 1/2
Surfacing: Gravel or slag!
7, Deck: C-15/32 Incline: 3
Vapor Retarder (Optional): Type G2 "Glasbase" or UL Classified vapor retarder.
Insulation (Optional): One or more layers or combination of the following: Polyisocyanurate, perlite,
glass fiber or wood fiber; any thickness.
Membrane: Three or four layers of Type G1 "Flintglas" ply sheet.
Surfacing: Gravel or slag;
r'� i
8. Deck: C-15/32 Incline: 1
.. • .
Vapor Retarder (Optional): Type G2 "Glasbase" or UL Classified vapor retarder. • •
.
Insulation (Optional): One or more layers or combination of the following: Polyisocyainnrete, pelite7.°
glass fiber or wood fiber
....
. .
....
....
. . • .
.. .. ....
•
. .
. .
.
. .
• • • •• •
•
.
•• •
..•
•
••• •
• •
..
Insulation (Optional): One or more layers or combination of the following: Johns Manville "ENRGY 3"
polyisocyanurate, perlite, glass fiber or wood fiber, any thickness,
Base Sheet: Two layers Type G2 "Glasbase Base Sheet" or two layers Type G1 "Flintglas Ply Sheet" ,
Surfacing: Type G3 "Flintglas Cap Sheet"
10. Deck: C-15/16* ncline: 1/2
*AII joints blocked.
Insulation (Optional): One or more layers polyisocyanurate, 2 in. min, wood fiber, 1 in. min, perlite, 3/4
in. min, glass fiber, 15/16 in. min.
Base Sheet: Two layers Type G2 "Glasbase Base Sheet" or two layers Type G1 "Flintgias Ply Sheet" .
Surfacing: Type G3 "Flintglas Cap Sheet"
11. Deck: C-15/32 Incline: 3
• •
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Santafe Tile Corporation
8825 NW 95`e Street
Medley, FL 33178
MI.AMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.eov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to
be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Contrpj :Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve t'l.iKat to hays t1 is
product or material tested for quality assurance purposes. If this product or material fails to {Defiant' in thaacaepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately, revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the righl tditewke tljig • •; •
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code. • • •
This product is approved as described herein, and has been designed to comply with the F1ajjcj pilding Cq,Ile
including the High Velocity Hurricane Zone of the Florida Building Code. • • •
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
• •
• • •
•• •
•
••
•
•
••
• •
• • • •
• •
••
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
•
•
RENEWAL of this NOA shall be considered after a renewal, application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0210.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 1 of 5
•
ROOFING ASSEMBLY APPROVAL
Category:
Sub -Category:
Material:
Deck Type:
Roofing
Roofing Tiles
Clay
Wood
1. SCOPE
This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera
Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Santafe `S' Clay Roof
Tile
Trim Pieces
Dimensions
L = 18"
W = 11.1"
Thickness = 0.39"
1= varies
w = varies
varying thickness
2.1 MANUFACTURING LOCATION
1. Bogota, Colombia
2.2 SUBMITTED EVIDENCE
Test Agency
The Center for Applied Engineering, Inc.
The Center for Applied Engineering, Inc.
The Center for Applied Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
MIAMI DADE COUNTY
APPROVED
Test
Specifications
TAS 112
Type I
Grade 1
TAS 112
Product.
....
. •
••.•
y•, • .. •
r1Ett Descon • • •
.. .
One piece high profile clayravf•the equipped with •
two nail holes. For nail-WI,hi ar setNiciAlhesive
set applications. ' • • • •
....
•
Accessory trim, clay roofpieoas for useat•Ilips,
rakes, ridges and valley tern:1110ns. Manufactured
for each tile profile.
Test Identifier
94-156-8
94-156-9
25-7205-1
Project: 07-07-00-91
(307023)
7161-03
Appendix II
7161-03
Appendix III
P 0402
P 0647-01
•
•
• • •
•. • .•. •
••
Test Name/Report
TAS 101
TAS 102
TAS 101
TAS 100
TAS 108
(Nail -On)
Static Uplift Testing
TAS 102 & TAS 102(A)
Withdrawal Resistance
Testing of Screw vs smooth
shank nails
TAS 108
(Mortar Set)
Date
Aug. 1994
March 1995
Sept. 1994
Dec. 1991
Dec. 1991
Sept. 1993
Aug. 1994
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 2 of 5
2.2 SUBMITTED EVIDENCE
Test Agency
Redland Technologies
Celotex Corporation Testing Services
IBA Consultants, Inc.
PRI Asphalt Technologies, Inc.
IBA Consultants, Inc.
IBA Consultants, Inc.
IBA Consultants, Inc.
American Test Lab of South Florida
3. LIMITATIONS
Test Identifier
P 0631-01
520305-01 thru 05
2353-4
SFTC-003-02-01
2353-70
2353-71
2353-93
RT0624.01-15
Test Name/Report Date
PA 108 July. 1994
(Mortar Set)
PA 102 June 1999
Restoring Moment Aug. 1999
TAS 101 12/06/02
TAS 101 09/22/03
TAS 101 09/22/03
ASTM C 1167 07/18/05
ASTM C1167-03 07/01/15
• •
• • •
•• •
3.1 Fire classification is not part of this acceptance. •
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be pern�r i in acc•ordan•ce with
• •
•
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratot}i to perform ggaiierly test.;.. •
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to rite, Miami-DadQ'County
Product Control Section for review. •
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications S=cis listetl
• • • •
• • • •
•
•
•
TAS 106.
•
•• •
• • •
• .•
•
•
section 4.1 herein. '
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope • urrlgf stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard
RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
MIAMI.DADE COUNTY
APPROVED
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 3 of 5
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Width-w (ft)
Santafe 'S'
6.7
1.5
0.958
Table 2: Aerodynamic Multipliers- X(ft3)
Tile
X (ft3)
X (ft3)
Profile
Batten Application
Direct Deck
Santafe 'S'
0.274
0.297
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Santafe 'S'
5.93
5.90
5.85
5.82
5.73
5.69
5.56
5.53
5.32
5.29
5.03
5.00
Table 4: Attachment Resistance Expressed as a Moment - Mf1ft-I12f) •,,,,• ••
for Nail -On Systems '•.' • • .. .
• . .
Tile Profile
Fastener Type
Direct Deck _ •
Aatfens •••
Santafe 'S'
2-10d Ring Shank Nails
21.8 �,.��
N[A _•
One#8Screw
29.161.2 •.... •
•••NtA .,
Two #8 Screws
38.281
•. NW ,,
One #8 Screw w/ Clip
57.311,2 ..'„'
•„N(R „,
Two #8 Screws w/ Clip
57.601
61.771
1. Approved screws as noted 'Product manufactured by others'. ,,,
2. When using one screw it must be installed in the inside hole located nearest to the hump of the Lilo. , .
•
• .
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbff • • • • • • ••
for Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment Resistance
Santafe 'S'
Tile Bond
38.93
Polyfoam Polypro AH 160TM
28.54
2 See manufactures component approval for installation requirements.
3 Flexible Product, Inc. Average weight per patty 10.4 grams.
4 Polyfoam Product, Inc. Average weight per patty 9.4 grams.
Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment Resistance
Santafe 'S'
Polyfoam Polypro AH 160Tm
63.85
Polyfoam Polypro AH 160TM
61.96
5 Paddy placement of 63 grams of Polypro AH 160TM
6 Paddy placement of 24 grams of Polypro AH 160TM'
•••
•••
•
•••
•
••
••
•••
•
•
•
•••
•
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mortar or Adhesive Set Systems
Tile Profile
Santafe 'S'
Tile Application
Mortar Set
Attachment Resistance
23.6
MIAMI•DADE COUNTY
APPROVED
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 4 of 5
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami -Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
18"
11.1"
MIAMI•DADE COUNTY
APPROVED
PROFILE DRAWING
. • ..
. .
....
. . . •
.. . .. . .
• •
• •
When using.gpmcrew....
use this hole.... .
"SANTAFE S" CLAY ROOF TILE
END OF THIS ACCEPTANCE
• .... .
. . • .
..• .. ....
•
. .
..
•
.
• .
•• . . •.
.. • ... .
. .
• .
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 5 of 5
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL. 33065
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.miamidade.2ov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revdce phis acceptanee, if it. i9 •: •
determined by Miami -Dade County Product Control Section that this product or material fails to Meet tpe nquirements • .
of the applicable building code. •'
•
• • •
This product is approved as described herein, and has been designed to comply with the, Florida•Building COP •;
including the High Velocity Hurricane Zone of the Florida Building Code. ' • • • ••
DESCRIPTION: ICP Adhesives Polyset® AH-160
• •
•• ••
• • •
• •
• •
• • • •
•
• •
•'
•
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, fifty, state ancd follow�i ��
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.' •• • • ••
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category:
Sub Category:
Materials:
Roofing
Roof tile adhesive
Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Product Description
ICP Adhesives
Polyset®AH-160
ICP Adhesives Foam
Dispenser RTF1000
ICP Adhesives ProPack®
30 & 100
Dimensions Test
Specifications
N/A
N/A
N/A
TAS 101 Two component polyurethane foaadhesive
. m.
PRODUCTS MANUFACTURED BY OTHERS:
• •••..
• . .
Dispensing Equipment • • • • • •• • •
..••
••
•
Dispensing Equipment•...
...•
. •
... •
.• •• ••..
• • •••
•
•
•
•
•
•
•
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current 1104 nhich list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof the adhesive. ' ••• • • • •• •
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
Closed Cell Content
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2127
ASTM E 96
ASTM D 2126
ASTM D 2856
Results
1.6 lbs./ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
+0.07% Volume Change @ -40° F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
MIAMIDADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[1] ASTM E 84 01/16/95
....
Trinity Engineering 7050.02.96-1 TAS 114 • •• • •• a3,'1•�146
•
P36700.04.12 ASTM D 1623 • • • Q4f143/12 •
•
P39740.02.12 TAS 101 02/21712
TAS 123 •
• • • • • • Celotex Corp. Testing Services 528454-2-1 TAS 101 1 Q/z3/98 • •
528454-9-1 '•
528454-10-1 •
520109-1 TAS 101 • • • 42/28(98 •
520109-2 •
• •
•
520109-3 •• • • •• • '
520109-6 ••
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B). ••••
•
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispensen.T'F WOO or L P. •
•
• Adhesives ProPack® 30 & 100 dispensing equipment only. •. • •
•
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. •
•••• •
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes €€tier ICP A1heMes
Polyset® AH-160 has been dispensed. •• • • •
• • •
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accaskr•j.e with the,•
'Placement Details' herein. Each generic tile profile requires the specific placement need trerein. . .
MIAMIDADE COUNTY
APPROVED
• • . •
•• •
•
•
.•
••• • • .
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Area
Minimum Paddy Gram
Weight
Eave Course - Flat, Low, High
Profiles
All Eave Course
17-23 sq. inches
45-65
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
head of tile 9-11 sq. inches at
overlap
12 grams per paddy
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
edge) 20-25 sq. inches each
bead •
•
17 grams per bead
....
. •
• •••• •••I
• •
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches •:•�•34 grav►'§•u$der pan '
LABELING:
•
•
•••• • •
• •
•••• •
•
•
All approved products listed herein shall be labeled and shall bear the imprint or identifiable rmloig of t4i ':: •
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Ai rpved" or tie Miami -
Dade County Product Control Seal as shown below. • •
•
• • • •
• • .
•• • ••• . •
••
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
MIAMIDADE COUNTY
APPROVED
• •
•
••
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
Nall through plastic cement
Patten required')
EMI. Course
MIAMI•DADE COUNTY
APPROVED
P.ddy {an•.eh ra•I
+++ Emm a:Ku ra
1t<C"
Fascia
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
• • • •
• •
• ••••
• •
1. Starting at the eave course,•a mifi4eGrti 2"
(50.8 mm) x 10" (254 mmt}). 1:' (25.4 mmm foam
paddy onto the underlaynlea,positio ned aas shown
under the pan portion oftbe.till' clos¢t to the
overlock of the tile beings ft... • • • •
•
•. •• •.••
••
• •
2. Continue in same manner. i Qre approximately 17 . •
(109.7 cm2) — 23 (148.4•cm2) Squarekcllasihesive •
contact with the underside ofthe tile' •
•• • • • • •
• •
••
High Profile / Single Pan Tile
• •
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Nail through plastic cement
hwh.n requiredl
Civil, Court*
MIAMI•DADE COUNTY
APPROVED
Paddy lBeneath Tile)
Fascia
Flat/Low Profile Tile
1 Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
•••.
3. Continue in same manner..Insul e approxj iely 10"
(64.5 cm2) - 12 (77.4 cm2)'uar4 inch acj>le4ve • •
contact with the underside.Gfthetile. • ....• •
••••
•
•
Medium Profile / Double Pan Tile
•
• •
•
•
•
••••
• • •• •
•
1. Starting at the eave coursei •apply. a minim ern 2" (5d.8• •
mm) x 10" (254 mm) x 1';(25.4 rim) fpam paddy •
onto the underlayment positioned as shMt Wider the •
pan portion of the tile closest to the ovsrlcck cif the . •
tile being set. Insure approximately 17 (10§•'gcm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
MIAMI•DADE COUNTY
APPROVED
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
....
. .
3. Continue in same manner. Itys�ire ilpproximately 17"
•
(109.7 cm2) - 19 (122.6 cm.).wp,re inch pilhrive •
contact with the underside of tlitile. .
•... • •
• • • •
. .
•. ..
•
•.•.
. • ..
•
• • • •
• •
• • •
•• •
•
••• •
• •
� •
• •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Flat/Low Profile Tile,
Medium Profile Tile
MIAMI•DADE COUNTY
APPROVED
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in2 (109.7-148.4 cm2) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned fowipaddy
under the strengthening.•rib IN flat tile,t1runder ttie• •; •
pan portion of the tile, closestio the uhBeflock for • •
• the second course tile tQ �g� • stalled. insure
approximately 8-9 in2 (511048.1 cm;) otOhesive
contact with the undersfde.of the tile:
•••
• • • •
(Instructions continued on fjecjge)
• •
•
• • •
• • •
•• •
• •
•
••
••• • • •
OS
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
High Profilerlo
MIAMI DADE COUNTY
APPROVED
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9 (58.1 cm2) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
• • .
• • ••••
• • • •
•• . •• • •
• • • •
• Y ♦
•
• • •
•••• • • • •
• •
•••• •
• •
•• ••
• • •
• •
• •
• • •
•• •
••••
• •
••••
•
•
• •
•
••
• • • • • •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in.
in contact with the pan tile.
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area.
Underlayment
Eave closure
(motar shown)
Weephole
Fascia Board
Steep pitch applications
(when required)
Sheathing
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
MIAMI•DADE COUNTY
APPROVED
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
•••••
•
3. Turn covers upside dorvvnex losing thedndersid'L•••;•
of the tile. Apply a miam1" (2�i•.ienin) x 10" •.
(254 mm) bead of adlhi'1irectly or.le innel
edge of each side of thl; pyer tile. J eav
approximately 3/4" (1i jto 1"Z25•41?hm)
from the outside edge•oi the tile, i nwaud, free of.: • • •
•
•
foam to allow for expafisitth. • • • •
• • •
•
- 4. Turn cover tile over alter foam is ipplii;d and
place onto pan tile coat.etl:sure : minim•um of • •
20 (129 cm2) - 25 (161.3 cm2) square kill
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
•
•
•
•
•
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17