Loading...
RF-13-2457Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 1263 NE 101 ST City: Miami Shores Folio/Parcel#: 11-3205-025-0040 'ram ��: 'v 7,1 ii BY: eS- - FBC 2010 Permit No. pi%- r-L/,/ 3 :"7. Master Permit No. RE-11-12-2195 ROOFING County: Miami Dade Zip: 33138 Is the Building Historically Designated: Yes NO X Flood Zone: OWNER: Name (Fee Simple Titleholder): CLAUDIO RODRIGUEZ Address: 1263 NE 101 ST Phone#: 305-899-9696 City: MIAMI SHORES State: FLA Zip: 33138 Tenant/Lessee Name: Email: Phone#: CONTRACTOR: Company Name: Precision Roofing Corp. Phone#: 305-822-9969 Address: 2646 West 77 PI City: Hialeah Qualifier Name: Joanna Tallet State: FLA Zip: 33016 Phone#: 305-822-9969 State Certification or Registration #: CCC 1329365 Certificate of Competency #: Contact Phone#: 305-822-9969 Email Address: Joanna@precision-roofing.com DESIGNER: Architect/Engineer: Phone#: • Value of Work for this Permit: $ Z 310 00 Square/Linear Footage of Work: yso SctF Type of Work: ❑Addition ❑Alteration anew akepair/Replace ❑Demolition Description of Work: New Roof Tiles Spanish S Santa Fe Clay Roof Tiles to new addition and existing roof Color thru tile: CLAY TERRACOTTA SPANISH S ***************************************Fees******************************************** Submittal Fee $ < �[J 'o(/ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO/CC $ DBPR $ _ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ 35/ _ 30 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be ..approved and a reinspection fee will be charged. / \ Signature Signature V Owner or Agent The foregoing instrument was acknowledged before me this The foregoi r strument was acknowledged before me thjs1 day of , 20 , by , day of OG , 20 t5,, by J Oa /1VQ-Ct. who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification a :a`u o did take an oath. Contractor NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My Commission Expires: ****************************** APPROVED BY My Commission E /*********************************** /15 Plans Examiner Structural Review (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) CARLOS A. URBINA /NJT"ary Public - State of Florida My Comm. Expires Jul 31, 2015 Commission # EE 116290 Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2^d Ave Miami Shores, FI 3313 Re: Owner's Name: Date: W((f ° l Qp„d�L,0AA Property Address: (Z(o5 1L) G • Roofing Permit Number: Dear Building Official: building because: (01 certify that I am not required to retrofit the roof to wall connections of my y,The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. n The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the So "ding Code (1994 SFBC) Signatu C L400 oo Ltttu z . Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above propert mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large CARLOS A. URBINA Notary Public - State of Florida -J My Comm. Expires Jul 31, 2015 Commission # EE 116290 • When the just valuation of the structure for purpose of ad va rem taxation is : quat to or more than S300.000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building applicatun from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Property Information Map http: //gis ims2. miamidade. gov/myhom e/printmap. asp?mapurl=http: //g... Property Information Map Aerial Photography - 2012 My Home Miami -Dade County, Florida 0 115ft This map was created on 10/23/2013 4:14:52 PM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. Summary Details: Folio No.: 11-3205-025-0040 Property: 1263 NE 101 ST Mailing ddress: CLAUDIO RODRIGUEZ 1263 NE 101 ST MIAMI SHORES FL 33138-2608 Property Information: Primary Zone: 1400 SGL FAMILY - 3001-3250 SQ CLUC: 0001 RESIDENTIAL - SINGLE FAMILY Beds/Baths: 4/3 Floors: 1 Living Units: 1 IAdj Sq Footage: 2,057 Lot Size: 13,000 SQ FT Year Built: 1941 Legal Description: PB 42-25 BAY BREEZE SEC MIAMI SHORES LOT 5 BLK 185 LOT SIZE IRREGULAR OR 25203-0821 1206 00 Assessment Information: Year: 2013 ' 2012 Land Value: $236,808 1$224,664 Building Value: $163,379 $185,921 'Market Value: $400,187 1$410,585 • sessed Value: $391,082 $384,545 Exemption nformation: Year: 2013 2012 Homestead: $25,000 $25,000 2nd Homestead: YES ' YES Taxable Value Information: Year: 2013 2012 Taxing Authority: Applied Exemption/ Taxable Value: Applied Exemption/ Taxable Value: Regional: $50,000/$341,082 $50,000/$334,545 County: $50,000/$341,082 $50,000/$334,545 City: $50,000/$341,082 50,000/$334,545 School Board: $25,000/$366,082 25,000/$359,545 Sale Information: Sale Date: 12/2006 Sale Amount: $775,000 Sale O/R: 25203-0821 Sales Qualification Description: Sales which are qualified View Additional Sales 1 of 1 10/23/2013 4:14 PM Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application F Section A (General Information) Master Permit No. Q 6 (1— l Z' 2.101c Process No. fliY CO Contractor's Name: PRECISION ROOFING CORP kb Address: 1263 NE 101 ST MIAMI SHORES, FL 33138 �) OCT u u 2 Jl3 �. ROOF CATEGORY ❑ Low Slope n Mechanically Fastened Tile ❑ Asphaltic ❑ Metal Panel/Shingles Shingles ❑ Prescriptive BUR-RAS 150 New Roof BY:..._ Mortar/Adhesive Set Tile ❑ Wood Shingles/Shakes GAS VENT: ❑ YES - NO ROOF TYPE II Re -Roof ❑Recovering ❑ Repair ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Area (SF) exIstnv4;,, OO ? f W: 3,000 N/A ❑ Maintenance Total (SF) 4,300 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels; clearly identify dimensions of elevated pressure zones and location of parapets. S Arin PPfl II A rinn STATF AN, Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) — Tiles Roof System Manufacturer: SANTA FE TILES Notice of Acceptance number: 12-0210.01 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): P1: -17.30 P2: -25.92 P3: -35.60 Maximum Design Pressure (From NOA Specific System): 61.9 (24 GRAMS OF POLYPRO) LARGE PADDY Method of tile attachment: POYFOAM ADHESIVE MEDIUM PADDY X TWO PADDY Steep Sloped Roof System Description Deck Type: CDX PLYWOOD 5/8" Optional Insulation: N/A Optional Nailable Substrate: N /A Optional Nailable Substrate Attachment: Roof N /A Slope: "/12 Underlayment/Base Sheet Type: 4„ ASTM D-226 #30 FELT Roof Fastener Type and Spacing: Mean Height 18' ft. 1 1/a 1 5/8 Tin Cans 6" OC (a Laos 8" 0 field r/s nails and (Maximum roof mean height 33' ft.) Adhesive Type: Ventilation: SELF ADHERED TILE UNDERLAYMENT Ridge n/a Cap Sheet Type: TARCO PS200 HT TILE UNDERLAYMENT Roof Tiles Covering: SANTA FE CLAY "S" ROOF TILES Drip Edge Type & Size: 3 x 3 eave drip galvanized @4" o.c. stagg. Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for values for Mr with the values from Mf. If the Mf values are greater than or equal to the 1 alues, for each area of the roof, then tile attachment method is acceptable. Method 1 "Moment Basedyi(e Calculations Per RAS 127" (P1: -39.1. x . .297 = -11.61 ) - Mg: 5.69 = Mil -17.30 Product Approval Mf 61.9 (P2: -68.1 xX .297 = -20.23 ) - Mg: 5.69 = Mil -25.92 Product Approval Mf 61.9 (P3: -100.7 xX, .297 =-29.91) - Mg: 5.69 = Mr1 -35.60 Product Approval Mf 61.9 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height -* Roof Slope I + 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 `Must be used with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (P, x L = x w: = ) - W: x cos 8 = Fr1 _ Product Approval F' (P2: x L = x w: = ) - W: x cos 0 = Fr1 _ Product Approval F' (P3 xL = xw:= ) -W: xcos 0 = Fr1 Product Approval F' Where to Obtain Information Description Symbol Where To Find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier 1 Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L= Length w= width Product Approval All calculations must be submitted to the building official at the time of permit application. DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Santafe Tile Corporation 8825 NW 95th Street Medley, FL 33178 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This replaces NOA# 10-1005.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. MIAMIDADE COUNTY APPROVED AO(' NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Deck Type: Roofing Roofing Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Santafe `S' Clay Roof Tile Trim Pieces Dimensions L = 18" W= 11.1" 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies MIAMI•DADE COUNTY APPROVED Test Specifications TAS 112 TAS 112 Product Description One piece high profile clay roof tile equipped with two nail holes. For nail -on, mortar set and adhesive set applications. Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Identifier 94-156-8 94-156-9 25-7205-1 Project: 07-07-00-91 (307023) 7161-03 Appendix II 7161-03 Appendix III P 0402 Test Name/Report TAS 101 TAS 102 TAS 101 TAS 100 TAS 108 (Nail -On) Static Uplift Testing TAS 102 & TAS 102(A) Withdrawal Resistance Testing of Screw vs smooth shank nails Date Aug. 1994 March 1995 Sept. 1994 Dec. 1991 Dec. 1991 Sept. 1993 NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 2 of 5 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date Redland Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) Redland Technologies P 0631-01 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 IBA Consultants, Inc. 2353-71 TAS 101 09/22/03 IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe 'S' 6.7 1.5 0.958 MIAMIDADE COUNTY APPROVED NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 3 of 5 Table 2: Aerodynamic Multiplyers- X(ft3) Tile A, (ft3) a, (ft3) Profile Batten Application irect Deck Santafe 'S' 0.274 0.297 Table 3: Restoring M ents d e to Gravity - M9 (ft-Ibf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Santafe 'S' 5.93 5.90 5.85 5.82 5.73 \ 5.69 / 5.56 5.53 5.32 5.29 5.03 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck Battens Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.161'` N/A Two #8 Screws 38.28' N/A One #8 Screw w/ Clip 57.311'1 N/A Two #8 Screws w/ Clip 57.60' 61.771 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Tile Bond 38.93 Polyfoam Polypro AH 160TM 28.54 2 See manufactures component approval for installation requirements. 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Polyfoam Polypro AH 160TM 63.8b Polyfoam Polypro AH 160TM 61.9b 5 Paddy placement of 63 grams of Polypro AH 160TM' 6 Paddy placement of 24 grams of Polypro AH 160TM. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Santafe 'S' Mortar Set 23.6 MIAMIDADE COUNTY APPROVED NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. 18" ,/ MIAMI•DADE COUNTY APPROVED PROFILE DRAWING When using one screw use this hole. "SANTAFE S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 5 of 5 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.zov/pera SCOPE:. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2-Component Foam Roof Tile Adhesive AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMIDADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2-Component Foam Roof Tile Adhesive AH-160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 ProPack® 30 & 100 Dimensions Test Product Description Specifications N/A TAS 101 Two component polyurethane foam adhesive N/A Dispensing Equipment N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content MIAMFDADE COUNTY APPROVED Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-1PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02.96-1 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 TAS 101 TAS 101 Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 01/16/95 03 / 14/96 10/23/98 12/28/98 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F 2 —W F'— MS MIAMI•DADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17/side on cap and 34/pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 MIAMFDADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nail through plastic cement Paddy (Beneath TIM) Underlayment 10 in. Eave Course Eave Closure Fascia Eave course only: Keep adhesive approx. 41n. up from weepholes Paddy (Beneath Tile) Eave Closure Eave course only: Keep adhesive approx. 4 in. up from weepholes MIAMI-DADE COUNTY APPROVED Nail through plastic cement \%24411Nos Eave Course 2 in /0. Paddy (Beneath Tile) Eave course only: Keep adhesive approx. 41n. up from weepholes Fascia Weephole Eave closure Drip edge Optional 2x4's for 1) Place enough adhesive to achieve 17 to 23 square inches In contact with the pan tile steep pitch applications 2) Turn covers upside down. Place adhesive 112 in. To 1 in. From outside edge of cover tile. Then install the We. Underlayment Remov top portion of the eave course cover tile. Abut to second course of pan Iles. Ensure eave end of pan and cover tiles are flush at save line. Eave closure (mortar show) Weephole Fascia Bo Nail through plastic cement Sheathing Optional Pointmp Mortar on longitudinal edges of tile NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 Nail through plastic cement Underlayment Eave Course Eave Closure MIAMFDADE COUNTY APPROVED ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Paddy (Beneath Tile) Nall through plastic cement Underlayment Eave Course Fascia Nail through plastic cement Underlayment Eave Course Paddy (Beneath Tile) Fascia Eave Closure Paddy (Beneath Tile) Fascia Weephole Eave closure Drip edge NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nail through plastic cement 3 in. x 3 in. Single paddy on under- layment Single paddy on top of tile Single paddy under tile Paddy (between tile) Paddy (under tile) Eave course 21n. X 71n. medium size paddy eave Fascia course only Nail through plastic cement teit)- er 3 in.x 3 in. Single paddy on underlayment Single paddy on top of tile Eave Course Nail through plastic cement • jt•ein.x 3 in. • Underlayment 1. Single paddy on under- layment 4 in. Single paddy on top of tile Eave Course Single paddy under tile Single paddy between tile 2 in. x 7 In. medium size paddy eave course only Fascia Weephole Eave closure Drip edge Single paddy between tile Eave Closure „if-4 4 2 in. x 7 in. medium size paddy eave course only Fascia END OF THIS ACCEPTANCE MIAMI-DADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Tarco Specialty Products, Inc. One Information Way, Suite 225 Little Rock, AR 72202 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.eov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 11-0912.04 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Pagel of 16 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment Asphalt, SBS, Polyester SCOPE: This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. PRODUCTS DESCRIPTION: Product 30# ASTM Specification Felt Manufacturing Location #1 & #2 EasyLay Manufacturing Location #2 Fiberglass Mineral Surfaced Roll Roofing Manufacturing Location #1 ASTM Organic Tile Underlayment Manufacturing Location #1 EasyMop SBS Manufacturing Location #1 MIAMI•DADE COUNTY APPROVED Dimensions Test Specification Product Description 3' x 72" rolls ASTM D226 Type II Asphalt saturated felt underlayment 3'x133'4" rolls 3' x 36'rolls 3' x 36'rolls 3' x 36'rolls ASTM D226 Type II Sheet material comprising a polyester substrate coated with bituminous coating for use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. ASTM D3909 Mineral surfaced glass fiber reinforced, asphalt coated roll roofing for hot mop or cold process application. ASTM D6380 Type II TAS 104 Asphalt saturated granular surfaced felt underlayment for hot mop application. Granular surfaced polyester reinforced, SBS modified bituminous membrane for hot mop or cold process application. Designed as a tile roofing underlayment. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 2 of 16 Product Fast90 Manufacturing Location #1 PS200HT Manufacturing Location #1 & #2 PS200"u Manufacturing Location #1 & #2 Dimensions Test Specification 3' x 36' rolls 3' x 66'8" rolls TAS 103 ASTM D249 ASTM D6380 TAS 103 ASTM D1970 3' x 66'8" rolls ASTM D1970 MS300 3' x 66'8" rolls ASTM D1970 Manufacturing 3' x 33'4" rolls Location #1 & #2 SS400 Manufacturing Location #1 & #2 NR500HT Manufacturing Location #3 MIAMI•DADE COUNTY APPROVED 3' x 66'8" rolls ASTM D1970 3' x 33'4" rolls 3' x 66'8" rolls ASTM D1970 Product Description Granular surfaced, asphalt -impregnated organic felt reinforced, bituminous sheet material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. Fabric surfaced, fiberglass reinforced, SBS modified bituminous sheet material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a shingle, tile and metal roofing underlayment. Film surfaced, fiberglass reinforced, SBS modified bituminous sheet material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. Fine granular surfaced, fiberglass reinforced, bituminous sheet material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle roofing underlayment. Smooth surfaced, fiberglass reinforced, bituminous sheet material with a self- adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. Film surfaced, non -reinforced, bituminous sheet material with a self- adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 3 of 16 MANUFACTURING LOCATIONS: 1. Greencastle, PA 2. Belton, TX 3. Coshocton, OH EVIDENCE SUBMITTED: Test Azency Atlantic & Carribean Roof Consulting, LLC PRI Asphalt Technologies Trinity I ERD IRT-Arcon Test Identifier ACRC06-013 TOT-003-02-01 TOT-029-02-01 TOT-030-02-01 TOT-041-02-01 TOT-042-02-01 T3580.10.06-2 T3580.10.06 T30160.08.09-R1 T10550.07.08 T32530.08.10 T33190.08.10 T43930.09.13-R2 T40790.04.12 T40780.04.12 T37610.07.11 IRT07-0006 IRT 07-0036 IRT08-0002 Test Name/Report TAS 103 ASTM D226 Type II TAS 110, ASTM D249 & D 6380 TAS 110, ASTM D249 & D 6380 TAS 110, ASTM D226 Type II ASTM D4798 & ASTM G155 TAS 103 TAS 103, ASTM D6380 ASTM D1970 ASTM D4798 & ASTM D1970 ASTM D1970 TAS 103 TAS 104 ASTM D6380 ASTM D3909 TAS 114-D ASTM D1970 ASTM D1970 ASTM D1970 Date 06/14/06 08/22/02 07/05/05 07/05/05 05/24/06 05/22/07 10/26/06 10/12/06 10/12/10 07/30/08 08/17/10 08/06/10 09/11/13 04/06/12 04/06/12 07/29/11 07/11/07 02/22/08 02/22/08 GENERAL LIMITATIONS — 30# ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 4 of 16 INSTALLATION REQUIREMENTS - 30# ASTM SPECIFICATION FELT: 1 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing 30# Felt. 3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS - EASYLAY: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. EasyLay shall be applied to a clean and dry surface. 4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional information. 5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended. Double layer application is best achieved by using 19" side laps, making sure the side laps are `shingled in' to shed water. 6. When installing EasyLay, the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 5 of 16 APPROVED ASSEMBLIES - EASYLAY: System E(1): Deck Type 1: Deck Description: Anchor/Base Sheet: Fastening: Surfacing: Anchor sheet mechanically fastened to deck. Wood, Non -Insulated. Minimum 19/32" plywood or wood plank. One or more plies of EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet). Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt. INSTALLATION REQUIREMENTS - EASYLAY: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyLay. 3 During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4 EasyLay shall be acceptable for use with asphaltic shingles, wood shakes and shingles, quarry slate, tile and metal roofing assemblies. 5 Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay. 6. Place a full width piece of EasyLay, parallel to the eave (low) edge of the roof. 7. Unroll EasyLay 2 to 3 feet, with the lay lines facing up, and position the end of it to the edge of the eave and rake. 8. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. 9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. 11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. 14. Align the next roll over the preceding sheet so as to form a minimum 4" overlap. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 6 of 16 15. Then install the just placed sheet, per instructions above. 16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. 17. Apply subsequent sheets in the same manner, with 4" side laps and 6" end laps over the preceding sheets. 18. When the top course is reached, lap about 6" of EasyLay over the ridge. 19. Install EasyLay a minimum of 6" up any vertical surfaces. 20. Stagger the end laps a minimum of 18" from the preceding course. 21. After installing EasyLay on the field of the roof, install drip edge at the eaves (if used). 22. When applying EasyLay in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. 26. Apply a minimum 1/16" thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LIMITATIONS - FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 7 of 16 INSTALLATION REQUIREMENTS - FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Fiberglass Mineral Surfaced Roll Roofing. 3. During installation of Fiberglass Mineral Surfaced Roll Roofing, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS - ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION REQUIREMENTS - ASTM ORGANIC TILE UNDERLAYMENT: 1. ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing ASTM Organic Tile Underlayment. 3. During installation of ASTM Organic Tile Underlayment, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 8 of 16 GENERAL LIMITATIONS — EASYMOP SBS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system. 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8 All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 5 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. Front View - Staged Tiles (Slope —►) Tile Staging Method Side View - Staged Tiles (Slope I ) 9. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 9 of 16 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. APPROVED ASSEMBLIES - EASYMOP SBS: System E(1): Anchor sheet mechanically fastened to deck, membrane adhered with hot asphalt or approved adhesive. Deck Type 1: Wood, Non -Insulated. Deck Description: Minimum 19/32" plywood, wood plank. Anchor/Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as specified in RAS 118, 119 or 120. (See #13 in Installation Requirements for back nailing) Surfacing: MIAMI•DADE COUNTY APPROVED Approved Roof Assemblies as specified below. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 10 of 16 INSTALLATION REQUIREMENTS - EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyMop SBS. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof tile and adhered roof tile applications. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyMop SBS. 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer. 9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application. 10. Place EasyMop SBS over metal drip edge in accordance with RAS 111. 11. Install the first course of EasyMop SBS parallel to the eave edge. 12. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge 11/4" approved ring shank type applied with a minimum of a 15/8" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 12" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 14. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 11 of 16 GENERAL LIMITATIONS — TARCO SELF -ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 40° F and rising. 4. Tarco self -adhered underlayments shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 5. Tarco self -adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self -adhered underlayments. 7. Tarco self -adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self -adhered membranes, wait a minimum of 48 hours before roof loading of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 10. All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 6 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. Front View - Staged Tiles (Slope —*) Tile Staging Method Side View - Staged Tiles (Slope ,1.) 11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 12 of 16 12. EasyLay, PS200mu, MS300, SS400, and NR5001ifsha11 not be left exposed as a temporary roof for longer than 30 days after application. PS200HT shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 13. NR500HT is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self -adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self -adhered underlayments or the ASTM standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 15. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. APPROVED ASSEMBLIES — TARCO SELF -ADHERED UNDERLAYMENTS System E(1): Anchor sheet mechanically fastened to deck, membrane adhered. Deck Type 1: Wood, Non -Insulated. Deck Description: Minimum 19/32" plywood, wood plank. Anchor/Base Sheet: Fastening: Membrane: Surfacing: MIAMI•DADE COUNTY APPROVED One or more plies of ASTM D226 Type II, ASTM D2626, or EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). All Tarco self -adhered membranes applied to approved Anchor/Base Sheet. (See #15 in Installation Requirements for back nailing) Approved Roof Assemblies as specified below. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 13 of 16 System F(1): Deck Type 3: Deck Description: Deck Preperation: Anchor/Base Sheet: Fastening: Membrane: Surfacing: Membrane self -adhered to concrete deck. Concrete, Non -Insulated. Structural concrete or concrete plank min. 2500 psi. The concrete deck shall be clean and dry and cured for a minimum of 28 days. None Membrane shall be back nailed with approved concrete fasteners and 15/8" approved tin caps at a maximum spacing of 9" o.c. at the head laps and be covered by the preceding layer. No back nail fasteners or tin caps shall remain exposed. Tarco PS200HT self -adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS — TARCO SELF -ADHERED UNDERLAYMENTS: 1. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Tarco self adhering underlayments. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS200HT shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles, wood shakes and shingles, and slate or simulated slate roof assemblies. PS200`4' and NR500HT shall be acceptable underlayments for asphaltic shingles, wood shakes, shingles, and metal roof panel assemblies. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer, water based acrylic or water based polymer modified primer. 9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application. 10. Place the underlayments over metal drip edge in accordance with RAS 111. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment, working from the center of the material continuously to the ends of the sheet (half of the length of the sheet is the center); taking care to avoid wrinkles and ridges. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 14 of 16 13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 gauge 1'/4" approved ring shank type applied with a minimum of a 15/8" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 9" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas "side laps, end laps, T-joints" to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply '/8" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing cement throughout the contact area of the 6" granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed, the membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1/8th" asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions, slope changes, valleys, curbs, and other roof top penetrations before any other sections of the roof. 19. When applying underlayments in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. 20. For ridge applications, center the underlayment and roll from the center outward in both directions. 21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 22. All protrusions or drains shall be initially taped with a 6" piece of like kind membrane. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 15 of 16 MANUFACTURER' S CONSIDERATIONS: 1. When using Fast90 and PS200HT in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended. When using EasyMop SBS in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended. 2. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 16 of 16