BPP-17-1986Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
Permit NO. BPP-8-17-1986
Permit Type: PoolsAillhirlpools/Hot Tubs
p t
rrri I Work Classification: New
Permit Status: APPROVED
Issue Date: 9/26/2017
Expiration: 03/25/2018
Parcel Number
Applicant
1532 NE 104 Street
Miami Shores, FL 33138-
1122320320370
Block: Lot:
JUAN CAMILO SUAREZ RUBIO
Owner Information
Address
Phone
Cell
SANDRA MILENA GIRALDO BOTERO
1532 NE 104 Street
MIAMI SHORES VILLAGE FL 33138-
(305)934-6115
1532 NE 104 Street
MIAMI SHORES VILLAGE FL 33138-
Contractor(s)
ALL COAST BUILDERS LLC
Phone
(786)299-2807
CeII Phone
Valuation:
$ 34,000.00
Total Sq Feet: 288
Approved: In Review
Comments:
Date Approved: : In Review
Date Denied:
Type of Work: Swimming Pool
Additional Info: NEW SWIMMING POOL
Classification: Residential
Occupancy: Private
Bond Return :
Scanning: 4
Fees Due Amount
Bond Type - Contractors Bond $500.00
CCF $20.40
CO/CC Fee $50.00
DBPR Fee $15.30
DCA Fee $15.30
Education Surcharge $6.80
Permit Fee $1,020.00
Plan Review Fee (Engineer) $120.00
Scanning Fee $12.00
Technology Fee $27.20
Total: $1,787.00
Pay Date Pay Type
Invoice # BPP-8-17-64775
08/03/2017 Credit Card
09/26/2017 Check #: 1143
Bond #: 3512
Amt Paid Amt Due
$ 50.00 $ 1,737.00
$ 1,737.00 $ 0.00
Available Inspections:
Inspection Type:
Fence
Final
Pool Deck
Wall Steel
Review Electrical
Review Planning
Review Building
Review Building
Review Mechanical
Review Structural
Review Plumbing
Review Plumbing
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing informat .n is a icurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Futhermore, I authorize the above-na ed con' actor . do the work stated.
September 26, 2017
Authorized Signature: Owner / Applicant / C. tr .r / Agent
Building Department Copy
Date
September 26, 2017
1
.!
.A6 " 9,� is
A
VS-0
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
BUILDING ❑ ELECTRIC ❑ ROOFING
PLUMBING ❑ MECHANICAL PUBLICS
JOB ADDRESS:
/S32 IllE /ov M
FBC20(+
Master Permit No ((l E
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
City: Miami Shores County:
Folio/Parcel#: ll —.2.z3z- o32- 0370
Occupancy Type: Load:
OWNER: Name (Fee Simple Titleholder):
Address: /S32 Ale /O Y
Miami Dade
zip: 33/.3 S
Is the Building Historically Designated: Yes
Construction Type: Flood Zone:
BFE:
NO
FFE:
(� l•� j Azb Phone#: "'30. 3 4 % �/
//• J
City: PlAileCGtA4 /i?
Tenant/Lessee Name:
Email:
State:
Phone#:
Zip: 33/3
CONTRACTOR: `Coom any Name: O1 £j% /cZs4, Z. Z..(0 T 6 Address: 7 Sid
City: C! State: Fe —
/6 fit daster
Phone#:
Qualifier Name: „la £ 1 oA Phone#:
State Certification or Registration #: C 6 I J-• �/ I T Ys Z Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: �/
Value of Work for this Permit: $ .3V 0 0 O Square/Linear Footage of Work: 2 86
76619112'07
Zip: —53 /J
7812.99 28 o 7
Type of Work: ❑ Addition ❑ Alteration New
Description of Work: Mid ;Ash i 1 fµ5 o l
City: State: Zip:
❑ Repair/Replace
❑ Demolition
Specify, color of color thru'tile:
Submittal Fee $ 13) • OD
$ ' t._O � Permit Fee O
Scanning Fee $ IL Radon Fee $ �' ' 3 0
.7
Technology Fee $ Training/Education Fee $
ICCF $ q a co/cc$ '
DBPR $
S • 30 Notary$
• Double Fee $
Structural Reviews $ I2v Bond $ 00
TOTAL FEE NOW DUE $ (. 7 :5
3�•c:"O
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
1 s..t
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City s State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that -all work will be done in compliance with all
applicable laws regulating construction and zoning. t. a• ► •
"WARNING-TO.OWNER: YOUR FAILURE TO RECORD A,, NOTICE. OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOURvPROPERTY: IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOURNOTICE OF COMMENCEMENT." I °, ;
Notice to Applicant: As a condition to the issuance of a building permit with an estimatedvalue'exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered �to,the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the sence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
•r
Signature
• • OWNER or AGENT
•
Signature. • I
•q
it • '�,
.The, foregoing instrume t was acknowledged before me this The foregoing instrument A s acknowledged before me this
i'� 4 a'}• .t q
• r -.din° 1' ,. ' /7
/ day of , 20 / by day of :NY� 20 by
�6 �� ��n�4G,� �
t� �'+�^ IA ,who is personally known to , who is personally known to
me or who has produced -6.1-6 -y01-3- 99-013—V as me or who has produced 1--t.T6)00- S`//- 67-00-1as-
identification and who did take an oath.
•
NOTARY PUBLIC: J „�
Sign:
Print:
Seal:
_`�`°�•, CLARA E RODRIGUEZ
MY COMMISSION #FF138588
ofd? EXPIRES July 5, 2018
***************r (A°T)3,98%9153 .
APPROVED BY
I( ririaSl arvC pirprgm..W.
i
,
RACTOR • r ,•
identification and who.did.take an oath.
NOTARY PUBLII I'
Sign:
Print:
'Seal: .;=a,++...
CLARA E RODRIGUEZ
MY COMMISSION #FF138588
'•.. o;tid!::- EXPIRES July 5.'2018
Plans Examiner
8/3//7
*******
Zoning
Structural Review Clerk
(Revised02/24/2014)
Property Search Application - Miami -Dade County
Page 1 of 1
Summary Report
Property Information
Folio:
11-2232-032-0370
Property Address:
1532 NE 104 ST
Miami Shores, FL 33138-2666
Owner
JUAN CAMILO SUAREZ RUBIO
SANDRA MILENA GIRALDO
BOTERO
Mailing Address
1532 NE 104 ST
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1100 SGL FAMILY - 2301-2500 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
3/3/0
Floors
1
Living Units
1
Actual Area
3,197 Sq.Ft
Living Area
2,210 Sq.Ft
Adjusted Area
2,643 Sq.Ft
Lot Size
8,850 Sq.Ft
Year Built
1970
Assessment Information
Year
2017
2016
2015
Land Value
$309,729
$309,729
$270,112
Building Value
$170,421
$171,795
$173,169
XF Value
$7,534
$7,640
1
$5,848
Market Value
$487,684
$489,164
$449,129
Assessed Value
$433,996
$394,542
$358,675
Benefits Information
Benefit
Type
2017
2016
2015
Non -Homestead
Cap
Assessment
Reduction
$53,688
$94,622
$90,454
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
32 52 42
RIVER BAY PARK ADD PB 40-72
LOT 16 BLK 4
LOT SIZE 75.000 X 118
OR 18739-4293 08 1999 1
Generated On : 8/3/2017
Taxable Value Information
20171 2016 2015
County
Exemption Value
$0
$0
$0
Taxable Value
$433,996
$394,542
$358,675
School Board
Exemption Value
�+
$0
$0
$0
Taxable Value
$487,684
$489,164
$449,129
City
Exemption Value
I
$0
$0
$0
Taxable Value
I
$433,996
$394,542
$358,675
Regional
Exemption Value
$0
$0
$0
Taxable Value
1.
$433,996
$394,542
$358,675
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
03/15/2017
$695,000
30466-1893
Qual by exam of deed
12/29/2011
$415,000
27949-3710
Qual by exam of deed
07/01/2005
$720,000
23704-2788
Sales which are qualified
08/01/1999
$246,000
18739-4293
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
http://www.miamidade.gov/propertysearch/
8/3/2017
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE
KNOW ALL MEN BY THESE PRESENTS: �` 6itc)LAWHEREAS, the undersigned Liu),cSo Z , J �j..�r4 is/are the fee
simple owner(s) of the following described property situated and bell in Miami Shores Village, Florida:
Address: I 2 Mr I a , CA 51015, F(, ?S V 3
Whereas, the undersigned owner(s) L 0& \ C, f u',frtL 6rt-\ (� 0
desire to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare
and agree as follows:
That the property will not be used in violation of any ordinances of Miami Shores Village
or Miami -Dade County now in effect or hereinafter enacted.
II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a
pool where the required enclosure is not on the subject property where the pool is located.
III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if
our/my property shall fail to meet code requirements for pool barriers, we, as owners will
immediately installs a protective enclosure to meet code requirements and will obtain a
permit for such fence.
IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or injury
that results from not having the enclosure.
V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in
the event that is damaged or removed by any case.
NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that
he/she will not convey or cause to be conveyed the title to the above property without requiring the
successor in title to abide by all terms and conditions set forth herein.
FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a
restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a
covenant running with the land and shall be binding upon the undersigned, his/her successors and assigns
and may only be released by Miami Shores Village, or its successors, in accordance of said Village then in
effect. /
i;JU(MA Suc.reZ, v
OWNER SIGN & PRINT
(Revised 05/2209
OWNER SIGN & PRINT
��_u
G doY'3— i`i'y-• 3 �
I Hereby Certify that on this day personally appeared before me1/4K C SJ'rr2 SCc.a/ &-r k,(d
and has produced ID # S 6.4 '11,3'91 nzs-o as identification and he/she acknowledge that he/she
executed the foregoing, freely and voluntarily, for purposes there in expressed.
SWORN TO ANDS day of
1k, EVA E VELASQUEZ
•'= MY COMMISSION # FF964005
EXPIRES February 23, 2020
IA07,3yyL's3 rkrMaNuW,ytiwyrrwn' OTARY PUBLIC STATE OF FL�.'IDAa
,20 Ii'
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
NOTICE OF REQUIREMENTS
RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT
I (W acknow of ge thaj a flew wimming pool, spa hot tub will be constructed or installed at
J.3z Nit 10 fl , ri:cst" rfil ri 13I5 Miami Shores, FL, and hereby
affirm that one of the following methods will be used to meet the requirements of Chapter 515,
Florida Statues and the Florida Building Code R4101.17.
Please initial the method(s) to be used:
Pf AS The pool will be equipped with an approved safety pool cover that complies with ASTM
F1346-91. (Submit Manufacturer's Specifications).
M a'-1 A continuous, one-piece (child) barrier meeting the requirements of Florida Building Code
R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of
attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's
Specifications).
1M 4 5 A combination of non -dwelling walls and fences (screen enclosure, child fence, masonry
fence walls, chain link or wood fence, etc.) will protect the pool perimeter. The plans must specify the type
and location of all non dwelling walls. Florida Building Code, R4101.17.1
Mk S Any combination of protection which incorporates dwelling walls with openings directly into the
pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building
Code, R4101.17.1.9 (Submit Manufacturer's Specifications),
AY Any combination of protection which incorporates dwelling walls with openings directly into the
pool perimeter and all doors will be equipped with a self -latching device with positive mechanical
latching/locking installed a min. 54" above the threshold. If this option is selected, submit plans showing all
types and location of all perimeter protection. The plans must also show the location and type of all
openings, and the hardware type for each location, (Submit Manufacturer's Specifications).
In accordance with the Code, the pool may not be filled with water without compliance with the
Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be
presumed to be unsafe. I understand that not having one of the above installed will constitute a
violation of Chap i r 515, F.S ., an d will be considered as committing a misdemeanor of the second
degree, pu isha• as provided in Section 775.082 or Section 775.083 F.S . This form must be signed
by the own : r/age t • d e prime contractor.
CONTRACT
CONT
NOTA
NATURE AND DATE
NAME (PLEASE PRINT)
-•7ln -
4lAV PUO •,
_�� CLARA E RODRIGUEZ
• MY COMMISSION #FF138588
EXPIRES July 5, 2018
(407) 398-0153 FloridallotaryService.com
OWNER'S SIGNA'i E AND DATE fir -! S 6i-t/L3-?-1(�30
tT o e. �vwret .
OW ► R'S NAME (PLEASE PRINT)
J.
NOTARY PUBLI
";; EVA E VELASQUEZ
:e: MY COMMISSION # FF964005
?art',
i4F71 Aa.c!Ss
EXPIRES February 23.2020
riundaNulu.yServrr ton,
Date
Miami Shores Vinage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
SWIMMING POOL OWNER'S CERTIFICATION
O5-02- 1611
Miami Shores Village
Building & Zoning Department
Attention: Building Official
I certify that I am the legal owner of the property described as
-OW) Co10 Soc , located at 1331 tJ( 10 4J
M, ►; vseJ, (I, 7313
In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I
understand and agree that the swimming pool to be constructed at the above address cannot
be used or filled with water until separate permit has been obtained for an approved safety
barrier, and such barrier erected, inspected and approved.
I further understand that this certification, however, does not eliminate the need for
obtaining a permit and erecting and approved barrier prior to final inspection and use of the
pool. de3
Le al Owner
9
Note: This certification is to be submitted with a swimming pool permit application in duplicate.
4
hores
illage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Notice to Owner — Workers' Compensation Insurance Exemption
'4.
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full-time
employees, including the owner, must obtain workers' compensation coverage. Corporate officers
or members of a limited liability company (LLC) in the construction industry may elect to be
exempt if:
1. The officer owns at least 10 percent of the stock of the corporation, or in the case of
an LLC, a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State, Division of Corporations; and
3. The corporation is registered and listed as active with the Florida Department of
State, Division of Corporations.
No more than three corporate officers per corporation or limited liability company members are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use
day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of
workers' compensation insurance coverage from the contractor's company for day labor, part tirne employees or subcontractors.
BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS
CONTENTS.
Signature:
25/'
Owner
State of Florida
County of Miami -Dade
The foregoing was acknowledge before me this / day of 4 N Sr , 20 / 7 .
By 4c'1 64"4.^i 0%/e/Y who is personally known to me or has produced
C.oni(o gva s6z6—y�3-790�-30
as identification.
Notary:
SEAL:
CLARA E RODRIGUEZ
�— • ` MY COMMISSION #FF138588
a; d'° EXPIRES July 5, 2018
(407) 398-0153 FloridallotaryService.com
ALL COAST BUILDERS, LLC
6467 SW 16 ST. CGC 1514432 CFC 1429677 786 299 2807
MIAMI, FL 33155 allcbllc@gmail.com
Date: August 24, 2017
State of Vol- AN
County of 4DGtcll
Before me this personally appeared /T amuta crfoki who, being
duly sworn, deposes and says:
That he she will be the only person working on the project located at:
4-3a tug wig /11101 h-i c,a re) 3313E
Sworn to (or affirmed) and subscribed before me this c23 days of
.2017
STATE OF 'Flo n cA COUNTY OF 'C-(1"/
On this cr, day of S o I. ,2017, Before me, a Notary Public in and for the
above state and county, personally appeared /?'744U4.Le G: .1-ti ri\ know to me or
proved to be the person named in and who executed the foregoing instrument, and being first duly
sworn, such person acknowledged that he or she executed said instrument for the purposes therein
contai -1. s his or her free and voluntary act and deed;
Vita,
NOTA LIC
SEAL
My Commission Expires
•, ";
a <<;. CLARA E RODRIGUEZ
MY COMMISSION #FF138588
U9• o. EXPIRES July 5, 2018
(407) 3973-0753 FloridallotaryService.com
FIXED CONTRACT AMOUNT
THIS AGREEMENT, Made as of June 25, 2017
Between the Owner:
And the Contractor:
For the Project:
Construction Lender:
Juan Camilo Suarez
Sandra Milena Giraldo
1532 NE 104 St
Miami Shores FL 33138
All Coast Builders, LLC.
CGC 1514432. CFC 1429677
6467 SW 16 Street
Miami F133155
786 2992807
New Swimming Pool
Construction Lender's Name: Owner
....
• • ..
.. • .. .
• ..
.. .
.
.
.... • .
. • . . .
..•
..
• .
.. .. •
•
•
..
• .
• •
•
..
.. .
•
.
.. .
..
..
ARTICLE 1. CONTRACT DOCUMENTS
1.1 The contract documents consist of this agreement, general conditions, construction documents,
specifications, allowances, finish schedules, construction draw schedule, information disclosure
statement, all addenda issued prior to execution of this agreement and all change orders or modifications
issued and agreed to by both parties. All documents noted herein shall be provided to the Contractor by
the Owner. These contract documents represent the entire agreement of both parties and supersede any
prior oral or written agreement.
ARTICLE 2. SCOPE OF WORK
2.1 The Owner agrees to purchase and the Contractor agrees to construct the above -mentioned
structure and fixtures attached thereto in (City of Miami Shores, Dade County and state
Florida) per the construction documents, allowances, finish schedules, all addenda, change
orders, modifications and specifications set forth in the specification booklet.
2.2 See proposal.
(06.24.2017)
Between the Owner:
And the Contractor:
CONSTRUCTION PROPOSAL
Juan Camilo Suarez
Sandra Milena Giraldo (Property Owner)
1532 NE 104 St
Miami Shores F133138
All Coast Builders LLC (Contractor)
CGC 1514432
6467 SW 16 St Miami F133155
786 299 2807
•
Initialed by: Owner (TCS Contractor r1 kJ
Contract
Project Name
Page 2 of 6
For the Project: New Swimming Pool
Contractor proposes to furnish labor, material and services as listed below for the above -mentioned
Project.
CONFRAGTOR.S; POOL SCOPE OF WORK
New Swimming pool 12`x 24'
-Pool form and steel placing
• • • •
-Install Main drains and light niches.
•..
•
.•
.. •. ••
-Pour concrete.
• • •
.
-Compact pool deck.
.
-Wire mesh installation
•....•
• •
• •
• • • •
-Form pool deck, pool equipment.
•, •,
•.
:
-Pour concrete and finish.
•
-Pool coping installation only.
-Pool water line tile installation only.
• •
•
• • • •
•
-Interior pool preparation (ready for plastering application).
. •
-3 Return lines
-1 Skimmer line
-1 Vacuum line
-2 Main Drain.
-2 Light niche less
-Pass all necessary inspections.
-Supply and install pool lights.
-Provide and install pool equipment (By Plans).
-Intel flow variable speed pump.
-150 Sq Ft Carbridge filter.
-Salt system.
-Site clean upon pool related debris only.
-New diamond bright (Standard colors).
-Plumbing Contractor service. •
-Electrical contractor service.
-Chemical start up, including salt.
-Walk thru with the client.
-Plans and Permits
30 350
-Remove and disposal existing concrete deck and pavers
-Prepare area to pour concrete (290 Sq Ft + 510 Sq Ft
-The Pool equipment will be located at east site of the
•
.•
•
.•
Initialed by: Owner
Contractor I1A 5
Contract
Project Name
Page 3 of 6
property
-Pool Heater
-Structure pool work is based on a Monolithie shell, we are
not including any Piling, if the Building Department request
for that it will be in additional charge.
SLAB CONCRETE WORK;
-Remove and disposal existing concrete deck ($2 per
Sq Ft)
-Remove and disposal existing paver area. ($1.20 per
Sq Ft)
-Provide new concrete slab in all deck area ($4 per Sq
Ft)
.
• • •
•...
• • • •
• •
• ..
3 650
. • • • •.
.••S
• • •
.
• • • •
•
_NOTINCLUDED
��
. .-
,_,
-Pool barrier.
-Coping and tile material. (Just included basic price of $288
for Copping and $288 for Pool tile = $576)
-Tile finish on deck area.
-Compaction test (if needed).
-Anything not listed on scope of work.
-Not tile installation included in the deck area
-Not Pool Piling.
.. .
.
... • •
PAYMENTS
15% Deposit (for plans drawing and revision)
35% when the plans be approved by the city
35% when to start with pool deck work.
15% at final inspection
TOTAL
34 000
SUBMITTE 1 BY: ALL COAST BUILDERS LLC
Contrac a r 1 Jara
All Coas : uild
CGC1514432, CFC 1429677
ARTICLE 3. TIME OF COMPLETION
Juan Camilo Suarez/Sandra Milena Giraldo
Property Owner
••
•
•
• •
.•
•
Initialed by: Owner IRS Contractor M A-5
Contract
Project Name
Page 4 of 6
3.1 The approximate commencement date of the project shall be (as soon as the plans approved by
the City of Miami Shores). The approximate completion date of the project shall be (2 Months), however
any change orders and/or unusual weather might delay or otherwise affect the completion date.
ARTICLE 4. THE CONTRACT PRICE
4.1 The purchase price of the project shall be set at the sum of $ 30 000, subject to additions and
deductions pursuant to authorized change orders and allowances.
ARTICLE 5. PROGRESS PAYMENTS • • • •
• • ••..
5.1 The Owner will make payments to the contractor pursuant to the attached conailu&tion draw .
schedule as work required by said schedule is satisfactorily completed. Owner shall.mekedraw •...•.
payments to contractor within (7, Seven days) days after request by contractor. Shooldhe owner fail to
make payment, contractor may charge a penalty of (10 percent) annually upon the .rrpaid amount until
•
•. ••
5.2 If payment is not received by the Contractor within (seven days) days after depi. y of payment
demand for work satisfactorily completed, contractor shall have the right to stop work or.terminafe th'e
contract at his option. Termination by Contractor under the provisions of this paragrnpti• hall not relieve
the Owner of the obligations of payments to Contractor for that part of the work performed prior to such
termination. Termination by Owner under the provisions of this paragraph shall not relieve the Mnet of
the obligations of payments to Contractor for that part of the work performed prior to suc; termoiaation.
••
ARTICLE 6. DUTIES OF THE CONTRACTOR
6.1 All work shall be in accordance to the provisions of the plans and specifications. All systems
shall be in good working order.
6.2 All work shall be completed in a workman like manner, and shall comply with all applicable
national, state and local building codes and laws.
6.3 All work shall be performed by licensed individuals to perform their said work, as outlined by
law.
6.4 Contractor shall obtain all permits necessary for the work to be completed.
6.5 Contractor shall remove all construction debris and leave the project in a broom clean condition.
6.6 Upon satisfactory payment being made for any portion of the work performed, Contractor shall
furnish a full and unconditional release from any claim or mechanics' lien for that portion of the work for
which payment has been made.
ARTICLE 7. OWNER
7.1 The Owner shall communicate with subcontractors only through the Contractor.
7.2 The Owner will not assume any liability or responsibility, nor have controls over or charge of
construction means, methods, techniques, sequences, procedures, or for safety precautions and programs
about the project, since these are solely the Contractor's responsibility.
ARTICLE 8. CHANGE ORDERS AND FINISH SCHEDULES
8.1 A Change Order is any change to the original plans and/or specifications. All change orders
•
•
•
• •
•
•
•
• •
Initialed by: Owner.ITC Contractor el k 5
Contract
Project Name
Page 5 of 6
need to be agreed upon in writing, including cost, additional time considerations, approximate dates
when the work will begin and be completed, a legal description of the location where the work will be
done and signed by both parties. 50% of the cost of each change order will be paid prior to the change,
with the final 50% paid upon completion of the change order. A 2% fee shall be added to all change
orders and overages more than initial allowances. Additional time needed to complete change orders
shall be taken into consideration in the project completion date.
8.3 Any delays or changes in finish selection schedules will delay the projected completion date.
ARTICLE 9. INSURANCE
•
9.1 The Owner will purchase and maintain property insurance to the full and insltirAlq value 01 the
• . .
••• .
project, in case of a fire, vandalism, malicious mischief or other instances that may gccti,r•.
•
9.2 The Contractor shall purchase and maintain needed Workman's Compensatigrlapd Liability •
insurance coverage as required by law and deemed necessary for his own protection'.,.. •
ARTICLE 10. GENERAL PROVISIONS
• •
.••
•.
. . .
• .•.
.
•
. . •
10.1 If conditions are encountered at the construction site which are subsurface or otherwise*
concealed physical conditions or unknown physical conditions of an unusual nature; wlarcn differ
naturally from those ordinarily found to exist and generally recognized as inherent ii on!tructibh•.
activities, the Owner will promptly investigate such conditions and, if they differ materially and cauSean
increase or decrease in the Contractor's cost of, and/or time required for, performance of any part of the
work, will negotiate with the Contractor an equitable adjustment in the contract sum, contract time or
both.
ARTICLE 11. HAZARDOUS MATERIALS, WASTE AND ASBESTOS
.
•
11.1 Both parties agree that dealing with hazardous materials, waste or asbestos requires specialized
training, processes, precautions and licenses. Therefore, unless the scope of this agreement includes the
specific handling, disturbance, removal or transportation of hazardous materials, waste or asbestos, upon
discovery of such hazardous materials the Contractor shall notify the Owner immediately and allow the
Owner/Contractor to contract with a properly licensed and qualified hazardous material contractor. Any
such work shall be treated as a Change Order resulting in additional costs and time considerations.
ARTICLE 12. ARBITRATION OF DISPUTES
12.1 Any controversy or claim arising out of or relating to this contract, or the breach thereof, shall be
settled by arbitration administered by the American Arbitration Association under its Construction
Industry Arbitration Rules, and judgment on the award rendered by the arbitrator(s) may be entered in
any court having jurisdiction thereof.
ARTICLE 13. PAYMENTS
TOTAL
1ST PAYMENT 15%..
2ND PAYMENT 35%..
3 PAYMENT 35%..
4TH PAYMENT 15%..
w
$ 34 000.00
$ 5 100. FOR PLANS DRAWINGS/REVISION AND PERMIT.
..$ 11 900, WHEN THE PLANS BE APPROVE BY THE CITY TO START
..$ 11 900, TO START WITH THE POOL DECK WORK
..$ 5 100, AT FINAL INSPECTION
•
•
.
Initialed by: Owner 3CS Contractor i" A-5
Contract
Project Name
Page 6 of 6
ARTICLE 14. TERMINATION OF THE CONTRACT
14.1 Should the Owner or Contractor fail to carry out this contract, with all its provisipns, the
following options and stipulations shall apply: '
14.1.1 If the Owner or the Contractor shall default on the"contract, the non -defaulting party may
declare the contract is in default and proceed against the defaulting party for the recovery of all
damages'iricurr"ed because of said breach of contract, including a reasonable attorney's fee. In
the case of a defaulting'Owner, the Earnest: money hereintmentioned shall be applied to the
legally ascertained damages. " - . . -
,yA
• ARTICLE 15. ATTORNEY FEES
14.1.2 In the event of a default by the Owner or Contractor, the non-defaultingmays tote
his intention to comply with the contract and proceed for specific performar•;•• ••••••
•
14.1.32 In the case of a defaulting Owner, the Contractoo.may accept, at his,cRtjgn the earnest•
money as shown herein as liquidated damages, should earnest money not cd'i 41ie expena see
date, the Contractor may make claim to the Owner for all work executed anijfpr j oven loss ith • •
respect to equipment, materials, tools, construction equipment and machinei,•iiVludin
reasonable overhead, profit and damages applicable to the property less the git money. •
• •
•
•
• •
• • •
{ • • •
15.1 In the event of any arbitration or litigation relating to the project, project performance or thi%;
contract, the prevailing party shall be entitled to'reasonable attorney fees, costs and expenses.
ARTICLE 16. ACCEPTANCE AND OCCUPANCY
r
14.1 Upon completion, the project shall be inspected by the Owner and the`Contractor, and any
repairs necessary to comply with the contract documents shall be made by the Contractor.
16.2 `T'he Owner shall not occupy the property until final payment has been received by the Contractor
and a Certificate of Occupancy has been obtained.
16.3 Occupancy of the project by the Owner in violation of Article 16.2, shall constitute unconditional
acceptance of the project and a waiver of any defects or uncompleted work.
16.4 Upon receipt of the final draw request from Owner, the Contractor shall provide the Owners a
Final Contractor's Affidavit certifying that all lienors, contracting directly with or directly employed by,
or about the construction or remodel of the Building, or about the subject Agreement have been paid in
full. Before disbursement of the final draw, The Contractor shall provide final releases for payment in
full of all subcontractors, material suppliers and laborers who have provided Notice to Owner to the
Owners
ALL' COAS , LLC
By: Manuel ; ra, ger
Juan Camilo Suar i'Sandrat,Milena Girajdo
Property Owner
• •
.••
• •
Initialed by: Ownert Contractor M�
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
nspection Number: INSP-301027 Permit Number: BPP-8-17-1986
Inspection Date: April 06, 2018
Inspector: Kendall, Travis
Owner: GIRALDO BOTERO, SANDRA MILENA
Job Address: 1532 NE 104 Street
Miami Shores, FL 33138-
Project: <NONE>
Contractor: ALL COAST BUILDERS LLC
Permit Type: Pools/Whirlpools/Hot Tubs
Inspection Type: Survey Final
Work Classification: New
Phone Number (305)934-6115
Parcel Number 1122320320370
Phone: (786)299-2807
Building Department Comments
NEW SWIMMING POOL
Passed
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
(\\Y->
sc'01/4
For Inspections please call: (305)762-4949
April 06, 2018 Page 1 of 1
•
N.E. 104th STREET
50' TOTAL RIGHT OF WAY.
18' ASPHALT PAVEMENT
•
O
O
N
'F. H
12' PARKWAY
CONC
"SLAB
O
O
N
•• •
•
••••
••••
• •
••••
••••
•
••••
*FOUND
•••P.R.M
QtMU' 4' Cc*C SIDEWALK
50.00'
FIR. 1/2 i
0.10'CL
O
O
06
LOT 15
BLOCK 4
F.I.P. 1/2-
9.99'
9.94'
12.93'
2264'
N
PbRL'FI
9 62'
ONE STORY
RESIDENCE
# 1532
LOT 16
BLOCK 4
29.30'
L'LLLLI 1 1 I I_LL)L'L
SCREEN �L_LLLL
S LLLL EQ__LLLLL
_LLLLJ,•nLLLLLCI-ILLLLLLLLLLLL LLL
_tLLLLLLLLLLLLLL_L.
_Ll ' ' ' ' ' ' ' _LLLLLLLL
_LI 1L70' _LLLLLLLL
_Ll _LLLLLLLL
_Ll _LL1/LE SLAB_
_Ll _LLLLLLLL
_Ll _LLLLLLLL
_Ll p _LLLLLLLL
Ll POOL _LLLLLLLL
Ll �i _LLLLLLLL
_LI
_LE
'CT
LI
LI
of
N
RE -PLAT OF
o d:
CONC
DRIVEWAY
ae
ade
2285'
25.81'
43
9.83'
9.95'
W�
P50.00'
MEAD WIRE
PLAT LIMITS
TRACT C MIAMI SHORES BAY
( PB 64-PAGE 97)
O
06
PARK ESTATES
• •
••
:LR. •1`2!0
••••••
• • •
• •
• •
• • •
•• •
OT t17
LOCK
0.37
C '
LP. 1/2 z
NC = AIR CONDHIIONING PAD
P.C.P. = PERMANENT CONTROL POINT
E.T.P. ELECTRIC TRANSFORMER PAD
LE. LANDSCAPE EASEMENT
C.B.S. = CONC. BLOCK STRUCTURE
NO ID = NO IDENTIFICATION NUMBER
NOTE: ONLY VALID VITH PAGE 1
SKETCH OF SURVEY
SCALE: 1" = 20'
ABBREVIATIONS AND LEGEND
F.N.D. = FOUND NAIL & DISK
U_E = UTILITY EASEMENT
F.I.P. FOUND IRON PIPE
F.I.R = FOUND IRON BAR
—x— = CHAIN LINK FENCE
CH =CHORD
S.I.R= SET IRON BAR
F.H. = FIRE HYDRANT
RES = RESIDENCE
C.B. = CATCH BASIN
RAN = RIGHT OF WAY
= CENTER LINE
F.N. = FOUND NAIL
CL = CLEAR
STY. = STORY
SAN = SIDE WALK
L =ARC. LENGTH
CONC. CONCRETE
4
• tom---
• N •
•• •
375.00;
•
•
•• •
• • •
•• •
_LI
0
•�
•
• •
•
•
• •
••••
••
•
•
1y
0
W
0
0
L_
c
"i
a_
LLJ
C
`3
0
B' DG DEPT
S.N. = SET NAIL
R = RADIUS
ENC. =ENCROACHMENT
-sr- = WOOD FENCE
- C.B.S. WALL
A = CENTRAL ANGLE
SJBJECT 0 CCAIRLI&MCE WI FH ALL FEDERAL
KARL F. KUHN
PROFESSIONAL SURVEYOR & MAPPER No. 5953
11844 S.W 203rd STREET
MIAMI, FLORIDA 33173
PH : 305-431 1846
786-317 3658
TYPE OF PROJECT:
BOUNDARY SURVEY
SCALE: AS SHOWN
DATE:
04-04-18
PROJECT LOCATION:
1532 N.E. 104th STREET
DRAWN BY:
I.C.
DRAWN No:
CITY, STATE & ZIP CODE:
MIAMI SHORES, FLORIDA 33138
PROJECT No:
18 / VP- 4936
DATE OF FIELD WORK: 04-03-18
SHEET: 2 OF: 2
4
/
_4) / N.E. 104th STREET
/
2�,•i i
i
• • • •
• •••
••••
•
••• • • • • •
•
• • • •
•
-/:////
/
•
••••
• •
•• •••
•••• •
..•.
• • • •
•• •
13
14
15
17
18
•..A19
20
/16
• •
4•
•
• • •
•
••
•
•
.•.
• • •
•••a•
•
••••.•
LOCATION MAP.
NOT TO SCALE.
PROPERTY ADDRESS: 1532 N.E. 104th STREET, MIAMI SHORES, FLORIDA 33138
LEGAL DESCRIPTION: LOT 16, BLOCK 4, OF RIVER -BAY PARK ADDITION,
ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 40, PAGE 72,
OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
CERTIFIED TO: O..— JUAN CAMILO SUREZ AND SANDRA GIRALDO
SURVEYOR'S NOTES:
1) The above captioned Property was surveyed and described based on the above Legal Description provided by Client
2) Bearings, if shown, are based on an assumed meridian and referenced on the centerline of NIA N/A , per plat
3) The lands shown hereon were not abstracted for easements,right of ways or other recorded incumbrances not shown on the plat,
and the same, if any may not be shown on this section. 4) Underground utilities are not depicted hereon.
5) Foundations and/or footings that may cross beyond the boundary tines of the parcel herein described are not shown.
6) Elevations are based on the National Geodetic Vertical Datum 1929. 7) Ownership subject to opinion of the Title.
8) Fence ties are to be the center line of the fence. 9) Wall ties are to face of the wall. 10) Not valid without the signature and original
raised seal of a Florida licensed Surveyor and Mapper. 11) This survey was prepared without the benefit of a Title Search; thereof,
only those easements on the recorded plat as shown. 12) This survey is prepared to be used exclusively as an aide to obtain Title
Insurance, no other warranties are hereby extended. 13) This survey depicted hereon is not covered by professional liability insurance
FLOOD ZONE INFORMATION:
DATE OF FIRM: 09-11-2009
COMMUNITY No: 120652
PANEL 0306 SUFFIX: L
FIRM ZONE: AE BASE FLOOD ELEVATION: 9'
BENCHMARK No: ELEVATION:
NOTE: ONLY VALID WITH PAGE 2
I HEREBY CERTIFY THAT THIS SURVEY VAS MADE UNDER MY RESPONSIBLE
CHARGE AND TO THE BEST OF MY KNOWLEDGE AND BELIEF. THIS SURVEY
MEETS THE MINIMUN TECHNICAL STANDARDS AS SET FORTH BY THE FLORIDA
BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17050
FLORIDA ADMINISTRATIVE CODE PERSUANT TO SECTION 472.027 FLORIDA
STATUTES. THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP.
KARL F_KUHN
PROFESSIONAL SURVEYOR & MAPPER No. 5953
STATE OF FLORIDA
KARL F. KUHN
PROFESSIONAL SURVEYOR & MAPPER No. 5953
11844 S.W 203rd STREET
MIAMI, FLORIDA 33173
PH + 305-431 1846
786-317 3658
TYPE OF PROJECT:
BOUNDARY SURVEY
SCALE:
AS SHOWN
DATE:
04-04-18
PROJECT LOCATION:
1532 N.E. 104th STREET
DRAWN BY:
I.C.
DRAWN No:
CITY, STATE & ZIP CODE:
MIAMI SHORES, FLORIDA 33138
PROJECT No:
18 / VP- 4936
DATE OF FIELD VORK+ 04-03-18
SHEET: 1 OF+ 2
••••
• • •
• • • • •
• • •
•• • •• •
•• •
•••
•
STRUCTURAL CALCULATIONS::::•
PROPOSED NEW POOL
1532 NE 104 STREET
MIAMI SHORES, FL 33138
*
• • •
• •
• •
••
•• •
•
••••
• •
• .••
• •
••
• •
• . ••
• • •
•
••• •
••
\\6`‘i,VEllik4/111/4
,.�!�,•. 62531
Vicente Yfdric`o, PE.
LIC. No. 62531
10776 NW 84 LN #5
MIAMI, FL. 33178
TABLE OF CONTENT
....
•
•
• •••.
• ••
•• • •• •
•
.•
•• •
•
••••
CHECK PILE CAPACITY y••..•
• •
• •
CHECK PUNCHING SHEAR • • • • • • 2 • • • • •
• • .
CONCRETE WALL , . • 3 •
• • •
••• . •
•
BOTTOM SLAB 5 • •
SLAB BAND DESIGN 7
•
1
Vicente Franco P.E.
CHECK NEW HELICAL PILE CAPACITY
POOL
POOL HEIGHT: h =
BOTTOM SLAB THICKNESS =
WALL THICKNESS =
fc=
fY =
PILE
5' FT
12!IN
8'IN
5000' PSI
600001 PSI
TENSION CAPACITY = 6 T
COMPRESSION CAPACITY = 121T
LATERAL CAPACITY = N/A
PILE DIAMETER = 1 3 IN
PILE SPACING LEFT b1 =
PILE SPACING RIGHT b2 =
6, FT
6 FT
TRIBUTARY WIDTH T1 = 3.67 FT
TRIBUTARY WIDTH T2 = 6 FT
CHECK TENSION CAPACITY:
TRIBUTARY AREA = 40.02 SF
HYDROSTATIC PRESSURE = 7.684 T
DEAD LOAD:
SLAB WEGHT = 150 * 12/12 *AREA / 2000 =
WALL WEIGHT = 150 * 8/12 * h * (T1+T2)/2 / 2000 =
DEAD LOAD = 4.21 T
UPLIFT (HP-0.6*DL) =
• •
• ••••
• ••
•
•• • •• •
• • •
..•
.
•
! •
••.•
• •
•• ••
• • •
• •
•
.•
•• •
3.00 T
1.21 T
5.16 T OK < TENSION CAPACITY
•
• •
••••
• •
• • •
•• ••
•
•
•
•••
• •
CHECK COMPRESSION CAPACITY:
LIVE LOAD = 6.40 T
DEAD LOAD = 4.21 T
TOTAL = 10.61 T OK < COMPRESSION CAPACITY
•'
•
• •
•
•
• •
•
•
•
. •...
• .
•
z
Vicente Franco P.E.
CHECK PUNCHING SHEAR AT BOTTOM SLAB
POOL
POOL HEIGHT =
BOTTOM SLAB THICKNESS =
WALL THICKNESS =
fc =
STEEL PLATE =
5 FT
12 IN
8 IN
5000 PSI
8' IN
d=
ho =
bo =
9 IN
21 IN
84 IN
REACTION OVER PILE:
LIVE LOAD = 6.40 T
DEAD LOAD = 4.21 T
Vu= 33.6 K
CONCRETE SHEAR CAPACITY:
....
• •
•. ....
• • •
•• • •
• • •
•• •
•
•
••••
• •
....
• •
•• ••
....
• •
••••
• •
•• ••
•
• ..
• •
• • •
•• •
CRITICAL AREA PERIMETER
(I)Vc = 181.8 K OK > PUNCHING SHEAR
OK HELICAL PILE
•
... •
••
•
• •
• •
• •
•
•
•
• •
• .
Cantilevered Retaining' Wall
Lic. # : KW-06010683
Description
Cantilevered Wall
Criteria
Retained Height
Wall height above soil
Slope Behind Wall
Height of Soil over Toe
Water height over heel
5.00 ft
0.00 ft
0.00 : 1
0.00 in
0.0ft
Vertical component of active
Lateral soil pressure options:
NOT USED for Soil Pressure.
NOT USED for Sliding Resistance.
NOT USED for Overturning Resistance.
Design Summary
Wall Stability Ratios
Overturning
Sliding
Slab Resists All Sliding !
4.01 OK
0.98 OK
Total Bearing Load = 1,500 Ibs
...resultant ecc. = 0.96 in
Soil Pressure @ Toe = 241 psf OK
Soil Pressure @ Heel = 209 psf OK
Allowable = 2,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe
ACI Factored @ Heel
Footing Shear @ Toe
Footing Shear @ Heel
Allowable
289 psf
251 psf
4.9 psi OK
0.0 psi
106.1 psi
Sliding Calcs Slab Resists All Sliding !
Lateral Sliding Force = 810.0 Ibs
less 100% Passive Force = 194.5 Ibs
less 100% Friction Force = 600.0 Ibs
Added Force Req'd
....for 1.5 : 1 Stability
Load Factors
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
Soil Data
Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure = 45.0 psf/ft
Toe Active Pressure = 30.0 psf/ft
Passive Pressure =
Soil Density, Heel =
Soil Density, Toe =
Friction Coeff btwn Ftg & Soil =
Soil height to ignore
for passive pressure
389.0 psflft
110.00 pcf
110.00 pcf
0.400
0.00 in
Top Stem
Stem Construction
Design Height Above Ftg
Wall Material Above "Ht"
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb/FB +fa/Fa
Total Force @ Section
Moment....Actual
Moment Allowable
Shear Actual
Shear Allowable
OK Wall Weight
Rebar Depth 'd'
Lap splice if above
Lap splice if below
Hook embed into footing
Concrete Data
15.5 Ibs NG
420.5 Ibs NG
1.200
1.600
1.600
1.600
1.000
fc
Fy
Stem OK
ft = 0.00
= Concrete
in = 8.00
# 4
in = 12.00
= Center
File = C:1C41CUA7EB-11GIA11532NE-11CANTIL-1.EC6
ENERCALC, INC. 1983-2017, Build:10.17.6.29, Ver:10.17.6.29
Licensee : Vicente Franco
•.••
•
Cal9ulatioas per ACr3 $.0 ACI 53004 f,1BC •
• • • 2012.cBC 2013, ASCE 7•40
•• •
•
•••. •
• • • •
• •
•• •.
• •
• •
• •
• . •
• . •
• • . •
•• •
....
• • • •
• •
• . .
•• .•
•
• •
.•. •
.•
•
•
•
• •
.•
•
•
•
•
Ibs =
ft-I =
ft-I =
psi =
psi =
psf =
in =
in =
in =
in =
0.429
900.0
1,500.0
3,493.8
18.8
106.1
100.0
4.00
13.24
6.00
6.00
psi = 5,000.0
psi =
•
Cantilevered Retaining Wall
Lic. # : KW-06010683
Description :
Cantilevered Wall
Footing Dimensions & Strengths
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
fc = 5,000 psi
Footing Concrete Density
Min. As%
Cover @ Top 2.00
Fy =
6.00 ft
0.67
6.67
12.00 in
0.00 in
0.00 in
0.00 ft
60,000 psi
150.00 pcf
0.0018
Btm.= 3.00 in
Footing Design Results
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe Reinforcing
Heel Reinforcing
Key Reinforcing
Toe
289
0
0
1,500
= 4.88
= 106.07
= #4@18.00in
= #4@18.00in
= None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd, Mu < S * Fr
Heel: Not req'd, Mu < S * Fr
Key: No key defined
File = C:1C41CUA7EB-11GIA11532NE-11CANTIL-1.EC6
ENERCALC, INC.1983.2017, Build:10.17.6.29, Ver:10.17.6.29
Licensee : Vicente Franco
Heel
251 psf
0 ft-lb
0 ft-lb
0 ft-lb
0.00 psi
106.07 psi
• •
•
• •
.. .
.... •
•
.. ..
., • •
•
• . .
•• •
••. •
• •
• • • •
.. •
•
.. .
•
•...
•
•
• • • •
• •
• . •
•. ..
•
•
•
•
•.• •
..
•
•
•
• •
.• •
•
•
•
Summary of Overturning & Resisting Forces & Moments
Item
Heel Active Pressure
Surcharge over Heel
Toe Active Pressure
Surcharge Over Toe
Adjacent Footing Load
Added Lateral Load
Load @ Stem Above Soil
OVERTURNING
Force Distance Moment
Ibs ft ft-lb
810.0 2.00
Total =
ResistinglOvertuming Ratio
Vertical Loads used for Soil Pressure =
1,620.0
810.0 O.T.M. = 1,620.0
= 4.01
1,500.0 Ibs
RESISTING
Force Distance Moment
Ibs ft ft-lb
Soil Over Heel
Sloped Soil Over Heel
Surcharge Over Heel
Adjacent Footing Load
Axial Dead Load on Stem
* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Stem Weight(s)
Earth @ Stem Transitions
Footing Weight
Key Weight
Vert. Component
0.0 6.67
0.0
500.0 6.33 3,166.7
1,000.0 3.33 3,333.3
Total = 1,500.0 Ibs R.M. = 6,500.0
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
•
ONE WAY CONCRETE SLAB DESIGN - ACI COEFFICIENTS
Design is for largest span and worst coefficient condition
Pool height h := 5 • ft
Maximum span is := 6 • ft + 0 • in
Width bs := 12 • in
Slab deep hs := 12 • in
ds:=hs-3.0•in --4 •in-0.5•-4 •in ds=8.25•in
8 8
Water unit weight
Concrete unit weight
Ultimate load
qu:= 1.2•hs•bs•'yc+ 1.6•bs•hp•-y14,
qu = 679.2 • plf
Maximum moment
M = qu • is
2
u
9
f := 60000 • psi
A :_
:= 62.4 • pcf
yc:= 150•pcf
Mu = 32602 • in • lbf
fc := 5000 • psi
0.5015• f2 • b• ds ys 2 2
B :_ —0.85 • fy • bs • ds
fc
-B-JB2-4•A•Mu
p := max 0.001$
2 • A
....
• •
....
•
.. • •• •
• • •
•• •
•
•
....
•
•
••••
• •
•• ••
• • •
• •
• •
• • •
•• •
•
•
•
• •
•
• •
••••
• •
• . .
•• ••
•
••• •
• •
••
•
•
•
• •
• •
p = 0.0018
As := p•bs•hs
Use #4 @ 12" top and bottom each way
Maximum shear
Vu := q� •• — — ds
2 1
Concrete shear capacity
As = 0.259 • in2
VU `15711 lbf,
•
4Vc := 0.75 • 1.0 2 • fc • psi • bs • ds 4Vc = 10501 • lbf
4Vc
2
= 5250 • lbf
Vu is less than half concrete capadty. No shear rebar is required
• •
• • ••••
• • •
.. • •• •
• • •
•• •
•
••••
• •
• •
•• ••
• • .
• •
• •
• • •
.. •
•
....
• •
••••
• •
• . .
.. ••
•
. •
•
••• •
• •
••
•
••
• •
• •
•
• .
7
EXTERIOR CONCRETE SLAB BAND DESIGNEDAS BEAM -ACI COEFFICIENTS
Design is for largest span and worst coefficient condition
Pool height hp := 5 • ft
WaI thickness tw := 8 • in
Maximum dear span In := 6 • ft + 0 • in
Pile cap width (assumed beam width) bb := 36 • in
Slab deep hs := 12 • in
4 4
db:=hs-3.0•in--•in-0.5•—•in db=8.25•in
8 8
Water unit weight 7W := 62.4 • pcf
Concrete unit weight -ye ••= 150 • pcf
Trbutarywdth by := 6•ft+3.67•ft
2
Ultimate bad
qu:= 1.2•(tw•hp+hs•bp) •7c+ 1.6•bp•hp•iw
qu = 5130.3 • plf
Maximum moment
Mu :_
2
qu ' In
9
Mu = 246253 • in • lbf
fY := 60000 • psi fc := 5000 • psi
0.5015 • f2 • bb • db2 2
f
A:= B := —0.85 • fy • bb • db
c
p :_
200•psi —B—JB2-4•A•Mu
fY 2 • `4 //
. •••.
. . .
.. •
.
.. .
. . .
•• •
.
.... •••.
. .
•... ....
. .
•• ••
. .
• • •
.. ..
.
• .
. .
. .
•
. •
• . . •
• • • •
.
• • .
.. •
•
••• •
• •
••
• •
• .
p = 0.0035
As:=p•bb•db
Use 5 #4 top and bottom over piles
Maximum shear
VU := qu .
i1 — \
db
2
As = 1.05 • in2
11864 •lbfM1
(I)Vc := 0.75 • 1.0. 2 • jfisi • bb • db (I)Vc = 31502 • lbf
ckVc
= 15751 • lbf
2
Vu is less than half concrete capadty. No shear rebar is required
• •
• • ••••
• • • •• •
•• • • • •
•• •
•
••••
• •
••••
• •
•• ••
• •
•
• •
• • •
•• •
•
••..
• •
••••
• •
• • •
•• ••
.
•
••• •
• •
••
•
•
•
• •
• •
•
.•
• •
•
...-... �.+.. ....v... ...... �..e....a.u+w •r..a•a.w awaa:Ja v AVvr aria aawwoo/real. +vav OZKVICES I IMILLINU SERVICES
oEc DYNATECHENGINEERINGCORP.
Miami, July 18, 2017
Mr. Manuel Jara
ALL COAST BUILDERS, LLC.
1532 NE 104th Street
Miami Shores, FL 33138
Re: Proposed Pool @
1532 NE 104th Street
Miami Shores, FL
Dear Mr. Jara:
WWW.DYNATECHENGINEERING.COM
..Tim
• •
• • •
•• •
•
••••
•
•. • •
• •
•• . •
• • •
• •
• •
• • •
•• •
••••
•• •
• • •
•••
•
••••
• •
••••
• •
••
• •
•••
••
•
•
•
• •
• •
• •
•
• •
• •
•
••• • • •
••
Pursuant to your request, DYNATECH ENGINEERING CORP. (DEC) completed a Subsoil Investigation
on July 18, 2017 at the above referenced project. The purpose of our investigation was to help determine
subsoil conditions relative to foundation design of the proposed structure.
A total of (1) standard penetration boring test was performed according to ASTM-D 1586 down to an
average depth of 25' below existing ground surface at the locations shown on the attached sketch.
The following graph was developed as a general condition below existing ground surface at the time of
drilling for the subject site (Subsoil conditions are non -homogenous, refer to field boring logs for exact
locations and soil description. Average depths are approximate and will vary in the field):
Average Depth
From To
0'-0" 0'-6"
0'-6" 2'-0"
2'-0" 3'-0"
3'-0" 9'-6"
9'-6" 10'-6"
10'-6" 25'-0"
Description
Topsoil and grass
Tan medium sand w/rock fragments u, A.L R VIEW ^
Tan silty sand w/rock fragments
Gray silt a APP__DATE )6)
Tan sand
Tan sandy limerock
Groundwater was measured immediately at the completion of each boring and was found at an average depth
of approximately 5' below existing ground surface at the time of drilling. Existing ground surface elevation
was not provided to us at the time of drilling. Design engineers must verify existing ground elevations as
well as FEMA Flood and County highest and lowest groundwater elevation for their design. Fluctuation in
water level is anticipated due to seasonal variations and run off as well as varying ground elevations
construction dewatering and pumping activities in the area and global warming. Site contractor must
familiarize himself with site conditions in the event groundwater controls and dewatering is needed during
construction. Surface flooding may result under hurricane conditions and should be taken into consideration
in the design of the project. The contractor shall monitor and make sure that groundwater levels on adjacent
properties are not adversely impacted due to the contractors dewatering activities. Specialty groundwater
and water proofing contractors shall be consulted for all work below the groundwater level.
1
750 WEST 84TH STREET, HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM
Re: 1532 NE 104th Street, Miami Shores, FL
I- Alternative I: Deep Foundation Systems:
Based on our understanding of the proposed structure and our field boring logs; deep foundation systems are needed to
support the proposed pool and slabs without detrimental settlement. Based on the Florida Building Code FBC 2014, 5th
edition, deep foundation systems shall consist of one of the following alternatives:
Alternatives
Pile Foundation
Approximate
Pile Depth
Size
Pile Capacity
in Tons
Pile Capacity
in•Ton9
•A4bwable Lateral
deity in'Thh: •
B.E.L.S.
Compression
Tension •
• •• • ••
• • • •
.•• •
Pin Piles / push piers
22' BELS
3"0 sch.80
5 Tons
•----`
1• Ia..
• N/A • •
Helical Piles
22' BELS
3"0 sch.80
12 Tons ,
6 'tQTaS,•
•... N/A • •
Auger Cast Piles
22' BELS
12 Inches
25 Tons
12'Tolis, •
• • • • •.1 Ton• •: • •
Auger Cast Piles
22' BELS
14 Inches
35 Tons
15.'Foas. •
_ • - 2 Tong' • • • •
.E.L.S.: Below Existing Land Surface.
•• ..
.• ••
•
For computer structural modeling of the building foundation system initial vertical Spring'constmtc 4,500 Kpi?or:
compression and 250 Kpi for tension may be used. The vertical spring constant vah hpile•load wde3
by estimated pile settlement and is based on our experience and review of available pile load tests ddta:and
settlement estimates in similar subsurface conditions and shall be refined as the structural model is developed.
Point of fixity for moment design of the 14 inches piles shall be taken at 12 feet below the cut off elevation.
Helical piles bearing capacity is a proprietary product dependent on manufacturer shaft type, size, and steel
strength as well as helix size, numbers, spacing, depth, soil profile and installation torque. Therefore, the
helical pile specialty foundation contractors and his engineer shall submit signed and sealed shop drawings
of the proposed helical piles to the building department. The above depths are minimum depth required
unless authorized by the geotechnical engineer. Predrilling may be required to achieve design depths.
Lateral Load for a pile Top Deflection of 1/4 inch. Lateral load capacities may be increased using battered
piles. Batter angles can be used for the pile installation of up to 2 inches per foot (Horizontal, Vertical).
However, care should be taken not to overlap adjacent piles.
In case of existing structures in the vicinity of the pile driving operation, care shall be taken not to create
excessive vibration. Vibration levels shall be monitored to verify compliance with county regulations. Steps
must be taken by the contractor to prevent excessive vibrations in the event excessive vibrations are
experienced during construction, alternative driving methods shall be implemented (ie: predrilling, jetting,
hydraulic push, etc...).
The minimum center to center of piles or adjacent piles shall be not less than two and a half the average
diameter for round piles, but in no case less than 36 inches to avoid load capacity reduction caused by group
effect. Piles shall be driven with a variation of not more than 1/4" per foot from vertical, and within 3 inches
of the specified plan location.
The installation of adjacent piles (located within 6 pile diameters o.c. of each other) on the same working
day is not recommended. We recommended that adjacent piles not be installed until the initial grouted pile
has set overnight, but no less than 12 hours (Florida Building Code 1810.4.8.).
The grout used in the pile installation shall develop a minimum compressive strength of 5000 PSI at 28 days. Large
grout volumes, possibly twice (or more) of the theoretical pile volume, are expected for proper auger cast pile
installation due to subsoil conditions. More so where former structures have been demolished and former piles removed
causing additional underground cavities.
All pile reinforcing must be designed by the structural engineer to resist all axial, bending, and shear stresses, and shall
be placed under the supervision of our Geotechnical Engineer to verify compliance with our recommendations. If the
pile is not reinforced over the entire length, we recommend a minimum of a single No. 7 bar be placed the full length of
the pile to verify pile continuity.
All work shall be performed in accordance with the applicable building code.
2
750 WEST 84TH STREET, HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM ` _ EC
Re: 1532 NE 104th Street, Miami Shores, FL
II- Alternative II: Shallow Foundation Systems Alternative for Pool:
Silty sand and silt were encountered at a depth of 2'-0" and extending to 9'-6". below k nd'surface. this
material must be removed and replaced with compacted gravel prior to pool ehcl; deck eoistxuction. The
above recommendation being achieved and verified; it is our opinion that therbrdsed pool be designe'c1'fc r
a shallow system with a permissible soil bearing pressure not to exceed 2,000.M. In are trot acct§§rele
for compaction and Flowable fill shall be used.
The following soil parameters shall be used for retaining wall designs:
•
• • •
• • ....
. .
....
• •
••
••
•••
••
- Soil unit weight moist: 130 pcf. Submerged: 70 Pcf. •• • •
- Angle of internal friction: 30 • • • ••
•
- Earth pressure coefficient Ka: 0.33; Kp: 3.0 • - •
- Angle of wall friction: 30 for steel piles, 20 for concrete or brick walls; 15° uncoated steel.
Any underground structures such as grease traps; septic systems, etc... must be supported on pile
foundations, unless the deleterious material (ie: silt, muck, peat, etc...) is excavated in its entirety and
replaced with compacted washed gravel such as pea rock or FDOT # 57 stone. Fasten utility lines to
underside of structural slabs to limit settlements.
•
••
Excavations shall not extend within 1 foot of the angle of repose next to existing footings or structures,
unless underpinned. Trenching shall be in compliance with the Florida Building Code, OSHA and
Trench Safety Act. Shorings shall be designed and inspected by Florida licensed professional engineer.
Excavation contractor must make provisions for hard excavation conditions.
All trenching work shall be in compliance with Florida Building Code, OSHA, and Trench Safety Act.
Provisions shall be made by the architect, engineer of record and contractor to address vibration / dynamic
loading; differential settlements when tying in new to existing structures. Mixing of different foundations
shall not be used unless provided with expansion joints to address differential settlements and vibration
transfer.
Also note that as a common engineering practice for existing and new construction; outside ground surfaces
must be sloped away from the structure as to avoid water accumulation and ponding. Rain gutters shall be
installed and all rain water shall be discharged over splash guards a minimum of 5 feet away from building
foundations. Verify all water, sewer, plumbing, sprinkler and drainage lines are properly functioning with no
leaks in the vicinity of the foundations.
An arborist must be consulted prior to any land clearing to verify compliance with local codes.
Detailed settlement analysis was beyond the scope of this report. However, we have compared the field test
data obtained in this exploration with our experience with structures similar to those proposed for this report.
The estimated magnitude of these settlements is less than '/2 inch differential and less than 1 inch total
settlements. Due to the granular nature of the subsurface materials, the foundation settlements should occur
as the loads are applied and should be virtually negligible by the end of the building shell completion.
If dynamic loading is proposed (ie: parking garage, etc...) this condition MUST be brought to our attention
to re-evaluate the applicability of our recommendations.
3
750 WEST 84TH STREET, HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL INFOODYNATECHENGINEERING.COM
C
Re: 1532 NE 104th Street, Miami Shores, FL
....
•
This report was prepared in compliance with the 2014 Florida Building Code, 5 .editioli. Site e1evafioiis
were not provided to us for the test locations. Depths reported on the field t?4 i, g logs tie ptoposed.pt1e
lengths represent the depth below existing ground surface as they existed on thedate of drilling. In thuy,ej
of subsequent filling, excavations or site work, the reported depths must bq •ad'jtisted tQYtp*esent Drop&
•••• .... • ..•
• •
.• •
••••
depths.
• •
....
•
•
The boring log (s) attached present (s) a detailed description of the soils encountered at to:tlqation (s).11li0
soil stratification shown on the boring log (s) is based on the examination of tete retoverea spil camp sand
interpretation of the driller's field log (s). It indicates only the approximate boundaries betwtet soil types.
The actual transitions between adjacent soil types may be gradual. Regardless of the thoroughness of a
geotechnical exploration there is always the possibility that conditions may be different from those of the test
locations, the nature and extent of such variations may not become evident until, during or after construction;
therefore; therefore, DYNATECH ENGINEERING CORP. does not guarantee any subsoil conditions
between the bore test holes. In accepting and using this report the client understands and accepts that all data
from the borings are strictly for foundation analysis only and are not to be used for excavation or back filling
estimates and pricing. Owner and site contractor must familiarize themselves with site conditions prior to
bidding. Client recognizes that actual conditions in areas not tested by DEC may differ from those
anticipated in DEC's report. Client understands and accepts that this can significantly increase the cost of
construction for its future projects. Client agrees that DEC shall not be responsible or liable for any
variations in the actual conditions of areas not tested by DEC. This report is not a Phase I and/or Phase II
Environmental Site Assessments. As a mutual protection to clients, the public and ourselves, all reports are
submitted as the confidential property of clients, and authorization for publication of statements, conclusions
or extracts from or regarding our reports is reserved pending our written approval. The scope of services
performed in the execution of this investigation may not be appropriate to satisfy the needs of other users,
and use or re -use of this document or the findings, conclusions, or recommendations is at the risk of said
user. Said user must contact DEC in writing to verify applicability of this report for their use. All work must
be conducted under the supervision of our geotechnical engineer. The discovery of any site or subsurface
conditions during construction which deviate from the information obtained from our subsoil investigation is
always likely and should be reported to us for our evaluation. All work shall be conducted in compliance
with the Florida Building Code FBC and OSHA workers protection rules and all applicable Federal, State,
County and City rules and regulations.
It has been a pleasure working with you and look forward to do so in the near future.
Sincerely yours,
Wissam Naamani, P. E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
Certificate of Authorization No.: CA 5491
,SPAD P
No. 39584 , '
* )444, 'O ` STATEOF
4
750 WEST 84TH STREET. HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM ` , EC
••••
• •
• • ••••
• • •
•• . ••
• • •
•
•
•
••••
• •
••••
• •
•• ••
•
•
•
•
• •
•••• • •
• •
••••
• •
• • •
•••
••
•
• • •
• •
_• -
• • •
•• •
TEST BORING REPORT
• ____
•
•
•
••• • • •
DYNATECH
ENGINEERING CORP.
TEST BORING FIELD LOG
CLIENT : ALL COAST BUILDERS, LLC.
PROJECT : Proposed Pool @
ADDRESS : 1532 NE 104th Street, Miami Shores, FL.
LOCATION : See attached sketch
DATE: July 18, 2017
HOLE NO.: B-1 • • • •
• •
DRILLER; I. G. •' •'
•• • •• •
• • •
•
•
•
DESCRIPTION OF MATERIALS
•
Depth..
, HAMMER
BLOW
SAI1IP1J R
•
•••I
. "NI"••••i
••;
0'-0" to 0'-6"
0'-6" to 2'-0"
2'-0" to 3'-0"
3'-0" to 9'-6"
9'-6" to 10'-6"
10'-6" to 25'-0"
2••••.
Hand•• '
--
TOPSOIL AND GRASS
TAN MEDIUM SAND W/ROCK FRAGMENTS
TAN SILTY SAND W/ROCK FRAGMENTS
GRAY SILT
TAN MEDIUM SAND
TAN SANDY LIMEROCK
$ '
•1
• -'
: 1 • 1•
-
•
26•
•• • •
6 ••
. A ••• •
A
8
A
A
10
A
-
A
12
12 16
15 17
31
14
A
A
16
A
A
18
A
A
20
18 22
19 21
41
22
A
A
24
A
A
26
A
A
28
30
32
34
36
38
. •
•
•
••
Water Level: 5'-0" Below Existing Land Surface at time of drilling As a mutual protection to clients, the public and ourselves, all reports are submitted as the
confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written
approval. H.A.: HAND AUGER; A: HOLLOW STEM AUGER; R: REFUSAL
•
•
5
750 WEST 84TH STREET. HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM l EC
•
• • •
•• •
•
•
•
•
•• • •
• • ••
•• •
• •
••••
• • • •
••••
••••
• •
•• ••
• • •
• • • •
• •
♦ • •
•• • ••• •
SITE PLAN
•
•
•
•
•
• •
• •
• • •
•• •• •
• • •
•
•
•
•
> HN IBARRA & ASSOCIATES, INC.
prn-fessi.on&1 Land Surveyors & Mappers
WWW.IBARRALANDSURVEYORS.COM
777 N.'./V, 72na AVENUE 2204 DEL PRAD° BLVD .SOUTH
SUITE 3023 SUITE NO. 202 UNIT 1
MIAMI, FLORIDA 33126 CAPE CORAL, FL 33904
P11: (305) 262-0400 PH: (239) 540-2560
FAX : (305) 262-0401 FAX: (239) 540-2564
NE 104th STREET
S ± 18' ASPHALT
PVMT.
50' TOTAL RIGHT-OF-WAY
0
tri
F.I.R. I/2'
NO CAP
O
cCi
0.46' CL
W.VD4
W.V.
F.H.
W.M..CONC..SWK
A
90°0'0'
9.99'
9.94'
C.L.F.
(5)
0. 15' ENCR.
90°0'0'
PWY
CONCRETE ..,
RETURN "j
(A)
W.M.
CONCRETE
WALK
75.00'
N
N
22.64'
PORCH
N
9.62'
A.
90°0'0'
CONCRETE I
DRIVE • j N:
ONE STORY
RES. # 1532
d OT.. 15
LOCK - ,a
29.30'
SCREEN
- TILE
PAVERS
22.83'
9.83'
C.5.
NC
; PAD
t
• •
•• •.
F.I.R. 1 /2"
NO CAP
FOUND
375.00 ----.s
4"X4"
•••• •
• • • ••••
• • • •
••, • •• • •
• • . •
Q •• •
0
DO •
a►. •••• ••••
• • • •
•••• ••..
-=—I.05' CL
• • .•
• ��j:�a• •
• •
• • •
•••
.•
• •
••
•
• • • • •
• • •
•• • • • • • • •
• •
••
C.Lf .F.
x / ENCROACHMENT
m NOTES:
'0 A. NORTH SIDE OF THE SUBJECT
N PROPERTY, CONCRETE RETURN
IS ENCROACHING INTO THE
RIGHT OF WAY OF NE 104TH
25.51' 9.95' STREET.
- ----..._. fc--x- 8. WEST SIDE OF THE SUBJECT
PROPERTY, CHAIN LINK FENCE
SHED I IS ENCROACHING INTO THE
O SUBJECT PROPERTY.
C'
ELECT.
METER
OVERHEAD
WIRE
90°0'0"'_ 0.37' CL
75.
F.LR. I/2" 00 � �-
NO CAP m J OVERHEAD
C.L.F. WIRE
LIMIT OF PLAT
(N.A.P.) RE -PLAT OF TR C MIAMI SHORES BAY
PARK ESTS PB 64-97
N.A.P.
c" )
m
x F.I.R. 1/2"
NO CAP
MAP OF BOUNDARY SURVEY
1532 NE 1 04th STREET, MIAMI SHORES, FLORIDA 33138
ARC
• AIR CONDITIONER PAD.
• ANCHOR EASEMENT.
• ALUMINUM ROOF.
• ALUMINUM BH.EO.
GRAPHIC SCALE
-20 0 I 0 20
(IN FEET)
1 INCH = 20 FEET
ABBREVIATIONS AND MEANINGS
• BLOCK CORNER
BROW/ RD COUNTY RECORDS
:.= BUILDING.
13301 MARK
3.• BASS OF BEARINGS.
- • BUILDING SETBACK UNE
^AInR ATED
• CAT01 BASIN.
• CONCRETE BLOCK STRUCTURE.
- CONCRETE BLOCKY/AIL
GMORD.
- 010RD BEARING.
C lAR -
.= CHUM UNK FENCE.
• CANAL MAINTENANE EASEMENTS.
T.= CONCRETE.
• CONC. FORCH.
• CONCRER SUB.
'.• CONC. UTILITY POLE.
• CONCRETE WALK
• DRAINAGE EASEMENT.
• DRAINAGE MAINTENANCE EASEMENTS
• DRIVEWAY
fGRfB.
AST.
ELEC1RC 80X
- ELECTRIC TRANSFORMER PAD.
- ELEVATION.
ENCRCACHL'E';
- FOUND IRON PIPE.
- FOUND IRON ROO.
• 9N5TED FLOOR E:P/ATION.
FOUND NAIL 4 015K
FRAME.
RAP.- FEDERAL NATIONAL IN"RM., PROP. COL. PROPERTY CORNER
F.N.= FOND NAIL RAV - MIT -OF -WAY.
11 = M01(NEIGRO RP.• RADIUS POINT.
I.F.. IRON FENCE RGE.- RANGE.
IN... EG.- INGRESS AND EGRESS EASEMENT. 5EC.= SECTION.
LB. • CaNJ.Xeof Authcnestm L.B.l7B06 STY.- STORY.
LP.= UGIIT POLE. 5NK.- SIDEWALK.
LF.E• LC NEST BOOR ELEVATION. 5.1.F.. 5ET IRON PIPE LB. 07806.
LM.E.• TAKE MANTENANCE EASEMENT. 5.P. • 5CREBNED FORD.]
= MIWIICi. S.- SOUR!.
M. = MEASURED DISTANCE. • - SECONDS
MB • MAIL 80X T = TANGENT
M.D.C.R- MIAMI DADE COUNTY RECORDS TB • TE)E.PMONE BOOR,
M.E. MAIMQANC EASEMENTS T.U.E.• TEORIOLOGY UTILITY EASEMENT
MEN. • MONUMENT UNE. TSB - TRA•9C 5'GNAL 8OR
MIT • MANMOIE. T.S.P.• TRAFFIC 5'GNAL POLE
AIL - MONUMENT UNE. TWP - TOWNXRP.
NA.P. • NOT A PART OE. UTIL- UTILITY.
NGVD • NATIONAL GEODETIC VERTICAL DATUM. U.P.= UDUTY POLE.
N. • NORTH. W.M.= WATER METER.
N.T9. • NOT TO SCALE. W.F. WOOD FENCE
R.NO. - NUMBER W.R= WOOD ROOF.
05 • OFFSET. W.M = WATER METER
0.11.L• OVWIEAD LITANY UNE5
O.R.B. - OFFICIAL RECORDS BOOK
OVH - OVERNANC
PAR, PAVEMENT.
PL. PLANTER.
PA - PROPERTY UNE.
P.C.C.• POINT Of COMPOUND CURVE.
P.C.= PONT OP CURVE.
PT.= POINT OF TANGENCY.
RTC.- POINT OF COVMENCOME T.
ROB.- RANT OF BEGINNING.
P.R.C.- POINT OF REVERSE CURVE
P.B.- RAT BOOK
PG, PAGE.
PAY. = PARKWAY.
PE/WANLY( RFRRJCE MONUMENT.
P.L5.- PROFESSIONAL LAND SURVEYOR
L - RECORDED P5TANCE.
RP.- RAIL ROAD.
W.F.- WOOD FENCE
W.L= IYDO)ROOK.
W.5.- WOOD 514ED.
W • WEST.
£ = CORER UNE.
LI • CENTRAL ANGLE.
.2E • ANGLE.
OVERREACT U0N)1Y UNE,
- CONCRETE BLOCK WALL
x x CMAIN UNE FENCE
O O IRON FENCE
.'/ WOOD FENCE
•° • BUILDING SETBACK UNE
— — — — • UTILITY EASEMENT
,•. •. LLw1ID ACC85 RAY
- NON-VEMCUUP ACCESS RN/
0.00 • Ex15TMG ELEVATIONS
CERTIFICATION:
JUAN CAMILO SUAREZ $ SANDRA GIRALDO
THE TARICH LAW FIRM P.A.
FIRST AMERICAN TITLE INSURANCE COMPANY.
DG PINNACLE FUNDING, LLC,
ITS SUCCESSORS AND OR ASSIGNS, AS THEIR INTEREST MAY APPEAR
LEGAL DESCRIPTION:
LOT 16, BLOCK 4 RIVER BAY PARK ADD ACCORDING TO THE PLAT THEREOF, AS
RECORDED IN PLAT BOOK 40, PAGE 72 OF THE PUBLIC RECORDS OF MIAMI-DADE
COUNTY, FLORIDA.
TITLE COMMITMENT NOTES:
THAT I HAVE REVIEWED THE COMMITMENT AND ALL ITEMS ARE SHOWN ON THE SURVEY.
THE ITEMS SHOWN HERE FORTH ARE PER SCHEDULE B-II OF FIRST AMERICAN TITLE
INSURANCE COMPANY COMMITMENT FILE NUMBER 1985-7, DATED FEBRUARY 02, 2017 AT 8:00
A.M.;
ITEM No. 10 RESTRICTIONS, DEDICATIONS, CONDITIONS, RESERVATIONS, EASEMENTS AND
OTHER MATTERS SHOWN ON THE PLAT OF RIVER -BAY PARK ADDITION, AS RECORDED IN PLAT
BOOK 40, PAGE(S) 72, BUT DELETING ANY COVENANT, CONDITION OR RESTRICTION INDICATING
A PREFERENCE, LIMITATION OR DISCRIMINATION BASED ON RACE, COLOR, RELIGION, SEX,
HANDICAP, FAMILIAL STATUS OR NATIONAL ORIGIN TO THE EXTENT SUCH COVENANTS,
CONDITIONS OR RESTRICTIONS VIOLATE 42 USC 3604(C). ROADWAYS AND LOT LINES SHOWN
ON SURVEY. NO EASEMENTS OR RESTRICTIONS ON SAID PLAT.
13
LOCATION SKETCH
SCALE =N.T.S.
LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY:
• THERE,MAY BE FASPNIENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON T1115
SURVEY.
• i HE PURPOSE OF THIS SURVEY 15 FOR USE IN OBTAINING TITLE INSURANCE AND FINANCING
AND SHOULD NOT BE USED FOR CONSTRUCTION PURPOSES.
• EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE
RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY.
• THIS SURVEY 15 SUBJECT TO DEDICATIONS, UMITATIONS. RESTRICTIONS. RESERVATIONS OR
EASEMENTS OF RECORD.
• LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY.
• BOUNDARY SURVEY MEANS A DRAWING AND/ OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK
PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND/OR NOT TO SCALE; THE WALLS OR
FENCES MAY BE EXAGGERATED FOR CLARITY PURPOSES.
• EASEMENTS A5 SHOWN ARE PER PLAT BOOK, UNLESS DEPICTED OTHERWISE.
• THE TERM 'ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS.
• ARCHITECTS SHALL VERIFY ZONING REGULATIONS, R`STRICSIONS, SETBACKS AND WILL BE
RESPONSIBLE FOR SUBMITTING
• PLOT PLANS WITH CORRECT INFORMATION FOR 'APPROVAL FOR AUTHORIZATION' TO THE
PROPER AUTHORITIES IN NEW CONSTRUCTION.
• UNLESS OTHERWISE NOTED, THLS FIRM HAS NOT ATTEMPTED TO IOCAW 49iitIG AND/OR
FOUNDATIONS. • •
• FENCE OWNERSHIP NOT DETERMINED. • • • • • •
• THIS PLAN OF SURVEY. HAS BEEN PREPARE* FOR *IE !ILLUSIVE USE OF THE ENTITIES
NAMED HEREON, THE CERTIFICATE • • • • • •
• DOES NOT EXTEND TO ANY UNNAMED PART • • •
•• •
FLOOD ZONE INFORMATION:. • • • •
THE NFIP FLOOD MAPS HAVE DESIGNATED WJiFIN DESCRIBEDON W BE SITUATES! OWR • • •
FLOOD ZONE A • • E' •
• •
BASE FLOOD ELEVATION: EFT. • • • • ••••
COMMUNITY.: 120652 • •
PANEL' 0308 • •
SUFFIX. L • • • • -
DATE OFFIRM: 0$M1/2009 • • • • • • • •
THE SUBJECT PROPERTY DOES NOT UE IN SPECIAL FLOOD HAZARD AREA.
•
•
•
•
• • •
• •
•
•
•.
SURVEYOR'S NOTES: • • • • •
I . IF SHOWN. BEARINGS ARE REFERRED TO RN ASSINMED MERIDIAN, BY SAID PLAT IN THE ON••RWT1D• OF
THE PROPERTY, IF NOT. BEARINGS ARE THER&ERRE") TO C0IJN TSWNSHLS MAPS. • •
2. i115 CLOSURE IN THE BOUNDARY SURVEY 15 ABOVE I :7500 FT. • •
CERTIFICATE OF AUTHORIZATION LB B 7800. • r
SURVEYOR'S CERTIFICATION:
1 HEREBY CERTIFY: THIS 'BOUNDARY SURVEY' OF THE PROPERTY DESCRIBED HEREON, HA5 RECENTLY BEEN
SURVEYED AND DRAWN UNDER MY SUPERVISION, AND COMPLIES WITH THE STANDARDS OF PRACTICE
AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS IN CHAPTER 5J-17, FLORIDA
ADMINISTRATIVE CODE PURSUANT TO 472.027, FLORIDA STATUTES.
8Y:
02/17/2017
/ /`'' JOHN IBARRA (DATE OF FIELD WORK)
PROFESSION4'.! LAND SURVEYOR NO.: 5204 STATE OF FIORIDA
(NOT VAUD WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR
AND MAPPER).
REVISED ON:
REVISED ON:
DRAWN BY:
TB
FIELD DATE:
02/17/2017
SURVEY NO:
17-000803-1
SHEET:
1 OF 1
;/ . r
ri NO 5204 O "_
STATE OF
:��DA�COR19P
IOC LAB'
L.B.# 7806 SEAL
V,
n
JOHN IBARRA & ASSOCIATES, INC.
Professional Land Surveyors 8 Mappers
NNY W.IOMRALANO•URVE70RS.CONI
77.7 N.W. TIRO AVENUE t•W OEL PRA-00 OLF0 SOUTH
SUITS MOSS
ARAM, FLORIDA 40154
Pt! (04) S•b01O0
MOO
w) 1/034101
SURE ISO. Sot LOOT
CAPS CORAL, FL 33001
PR: (STD) 040.21100
FAE: (ESE) 040.4O M
NE 104th STREET
N
r 6" A511140
1YATT.
SEr TOTAL RCNT-0, WAY
IJ.11 Itr
NO CA.
15)
CD O. IIS�ENCRC"
Q+ - •.n fJ.R U7 d
NO W
CD
w.v7M
R•w.v.
7'fJt
90.0'0*
9.99'
i•
9.94'.
CONC..DWK
CONCRETE
WALK
RLM
75.00'
CONCRETE
RETURN
• CONOterr
. W,M
9.63'
4.
zONE STORY
`�y•YRTS. 1532
Yv` LOT-16
BLOCK =4
�LZL�.I:I• � E'
_LLLL� lL{t� / •
6.
//22.''1/'rORCM
✓' s A N
LIIATOF, IKATv.-
(N•A.Pd j' ARE=P. AT`Or:1R C MIAMI
° PARK ESTS'PB 64-9
N.A.P.
.:')ram-�ii. _.r... vy..,.,. ...•.-: ..,.
75.
M[TER
LECT
OVERNEAD
WIRE
2ZE3'
w.M.
fJ.R 1/2'
NO CA/
r
Poo
375.00-la PAM
47r4'
--1--1A.09'CL LOT- 17
p7 0 elCCR -4
4
Z3.6Y//// 1}9.95j�
ENCROACHMENT
NOTES:
1. 47410*OF ME'MACY
PROPERTY. CONCRE7QRk7YNN
rDICRO1G•1010 EI7C RN
RIOROFIIMYOFNE (OR 4
. 4ntEEr..
'terrace anRsmart'
A P10001011C CHAOUAW FENCE
• IRAd)O4010011 0ME
5 �a �t• 04111AECTPRO•E(R7Y
ire
NO CAI
T{k F
-..
MAP OF BOUNDARY SURVEY
1532 NE 104th STREET, MIMM 51104*5, FLORIDA 33136
GRAPHIC SCALE
-20 0 10 20
(INFO
1INCH • 20FEET
APPRA4MTIONE AN01wo1NRs
,r.m•, MiWIO PMr&
WC. ••••0011111N014.2•15
••F••••MOWS
ea • •� NPS
0.60•VC,OMtMY.
i•a.10004O
0A
Hrg▪ r. i=ftem01•100%
R•Aan•OK
q-▪ • M4.,
Mt. 61100.0.
CEIM RCA7ION:
JUAN CMALO SUAREz 4 5ANDRA WRNDO
THE TARIC1 LAW rat l PJl
r1257 MAN T TL* INSURANCE COMP164e.
OG MIRACLE FUNDING. LLC.
ITS SUCC13550R5 AND OR A551GN5, A5111E 2 nNTERGST MAY APRAR
LOT I C. BLOCK 4 RIVEK SAY PARR POD ACCOROMG TO THE RAT 111EREOr. A5
RECORDED IN FLAT BOOK 40. r C 72 Or TM FUBLIC RBCORDS or MIAMI-DALE
COWIN. FLORIDA.
MMTLECOMMITMENT NOTES:
RpFI)NVE)E1M31ED REOONL/1e4TA1DALL trod SARE worm DN DIE SURVEY.
11!ITIAO&OWNMERE)ORTNARE1613044 UM CI, FAST AMOCANTORE
ISUR CE=PW COMEIIEMFIEMReEr 11054, DATED FEIRWRY02,3011ATt04
AlL;
ITB116. 10RESN00N,Q DEDA:Afl0NS COMM RESOMITI ]IS
01TNREMTUM MOMON THE PLAT OFMANY MAX AOOI101L
DOOR Mt MORN 72 RUT DORM ANY ODa,TMNT. cote:0m m
AM EI10E LANTATIa1 OR LNSC11.4NATEWWEOONRACK
)WAIIIN. PANSIAI. STATUS CRANDON& OINMATO THE ORM SUCH
GoVDMON Get RESTIWO063 VIOLATE 46 uscse*(13 *moms At, sip
maws: ND EASSIEr7s OR(Es71ECT1oa WSW RAT.
LEGAL NATIEJ TOACCOIMANY_SK61CN Of1NRNEY:
wee wuuwrtr.. •WD. M •AC11m1 6 C SO/1•04
MR-
• mrwOOO'MAMMO 0'••IS.4 10RS1 FAX 9SSM'!
EDT=.O'MMM3. e•e, AhSCAR U...TOR.
MA•
. TAR N•e•.ro SOCAe•3. .,A0A.e'ucOe
• (61000/06H0•01)WOW Ot A,C •i mtt M/M'
• 47110•0 4RVIVLS00• ma 3.•SO CQ!CSOC• O.O AS TZO.OA
)C0010104111(w00. O7UD OMAR:a •...O .'XAi.4OR ET.3 v • '-O+../ a
.•I17.AS RP•10P3 FDR awn. rumen.
• •e0/R.0 V *004••,• M •OOr. V.DI OfACRf O•9,rO0
• .100. 0#0•:••A• ••.Y3.3A7A• MLY:O0W 000•0,0M
• Fort.•. Rex vfle, SA0001•AV6031C10.6. 4011O3 A0•
11000011011•M,•0
• 404HMw01 COM, ••O0*31 „OR 1/••CV4 FOl4.•lO•P'O• : ••S
MORN41'NO•D, v4410.00.
•t 0101Aat W0. 1.34* •. .47 nr0••rm0)'dfA4(031.1 Ales
.4.-
•)OR0111SS XSCRAMS.
"▪ coo sow nRMAnork
0010•0 10.01 000100000•e0 0.0101110WO OR•1WOID0010002600700
WAIL M0
0011701011 0001101
•SlM11r1,0O4•R00SMOT1.0A•tl•A00D101.00 0a
agrarama Awn
•. 0.10"10043IIR 100410:19.. 47M10010ire. 010) •IA•• tK007,-u?
M 00OLTSPIOf. SMOGS OZR* 040t 4r0:11•.100OrmD!
S w4 ODMR• re E01••,•' M47 Saps 1e•SCO R.
3 DIODat OF AOI WIAD• 0 • TOG.
TOM
SOffOMO RMINDOI F911101A?0t404 140 MMfMG103 OF R1L.
Al /R A •O,OO. OOOO R[LWOWOpffWIUM su04L•00 s O•rrts+.7..!O•P.
Q02J17/20f7
N. JJJJJJuuu A
JOINMAIRA OM OFMDKM
rmmD•{l•ACa0Oa¢a. 5204 RASO REST
110100.0000RAE !MOM AO nit WOOL 0RJ5717 ANO.O••Q•OC 1b5.O1
A01n.Rn.
- 110.010 o4
•
FIELD DATE
•
02,11712017
• ••• �YNa,
• •• •• s
• • • • 4
• • • • &E •
M•- •
14F••I •
• •
• • • • • • • • • • • •
• • • • • • • •
• • • • • • • • •
• • • • • • • • • •
• •• •• • • • •• ••
000 • • • 000 • •
GENERAL NOTES
.... •
. . ,.•
• .• ... •• •
. •
Soil borings on unmarked vacant property should be considered preliminary with furthet b- ri••••• •••'•
building pad(s) are staked out.
• • . .
,•
.
.... .
Soil borings on existing structures that are to be demolished should be considered preltmin y andadditional bbfi� 9
would need to be performed after the structure(s) has been demolished and proposed Il' •
• • • • ilding take out. • • •
.. .. ....
As a mutual protection to clients, the public and ourselves, all reports are submitted' as ' ential property ofclieMs, and
authorization for publication of statements, conclusions, extracts from or regarding ouz reports is reserved-pending•oxr
•
written approval.• .. . •.. . •
KEY CLASSIFICATION & SYMBOLS
Correlation of Penetration Resistance With
Relative Density and Consistency
Cone Penetration
Tests
(Ke/cm31
Sands 0-16
17-40
41-80
81-120
Over 120
Silts &
Clay
0-3
4-9
10-17
18-31
32-60
Over 60
Standard.
Penetration
(Blows/ft.)
0-4
5-10
11-20
21-30
31-50
0-2
3-4
5-8
9-15
16-30
3 1 -50
Soft
Medium
Moderate Hard
Hard
Very Hard
Relative
Density
Very Loose
Loose
Firm
Very Firm
Dense
Very Loose
Soft
Firm
Stiff
Very Stiff
Hard
Boulders
Cobble
Gravel
Sand
Silt
Clay
5%- 10%
10%.- 30%
30% - 50%
0%- 5%
6%- 10%
11% - 20%
21% - 35%
> 35% And
Particle Size
> 12 in.
3 in. to 1 in.
4.76 mm to 3 in.
0.07 mm to 4.67 mm.
0.005 mm. to 0.074 mm
< 0.005 mm
Modifiers
Slightly Silty or Clayey
Silty or Clayey
Very Silty or Very Clayey
Slightly Trace
Trace
Little
Some
Rock Hardness Description
Rock core crumbles when handled
Can break with your hands.
Thin edges or rock core can be broken with fingers
Thin edges or rock core cannot be broken with fingers
Rock core rings when struck with hammer (cherts)