WS-18-1981Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INS►P-309000 Permit Number: WS-7-18-1981
Scheduled Inspection Date: August 22, 2018
Inspector: Riveron, Alexis
Owner: KEATING, PHILIP & LISSET
Job Address:145 NE 101 Street
Miami Shores, FL 33138-
Project <NONE>
Permit Type: Windows/Shutters
Inspection Type: Final
Work Classification: Window/Door Replacement
Phone Number (305)336-1715
Parcel Number 1132060131940
Contractor: FLORIDA HOME IMPROVEMENT Phone: (954)792-4415
Building Department Comments
REPLACE 1 WINDOWS
Passed
f
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -Inspection fee is paid
Infractto Passed Comments
INSPECTOR COMMENTS
False
Inspector Comments
August 21, 2018
For Inspections please call: (305)762-4949
Page 8 of 22
Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
Permit NO. WS-7-18-1981
Permit Type: Windows/Shutters
ri ark Classification: Window/Door Replacem
Permit Status: APPROVED
Issue Date: 8/3/2018
Expiration: 01/30/2019
Parcel Number
Applicant
145 NE 101 Street
Miami Shores, FL 33138-
1132060131940
Block: Lot:
PHILIP & LISSET KEATING
Owner Information
Address
Phone
Cell
PHILIP & LISSET KEATING
145 NE 101 Street
MIAMI SHORES FL 33138-
(305)336-1715
145 NE 101 Street
MIAMI SHORES FL 33138-
Contractor(s)
FLORIDA HOME IMPROVEMENT (954)792-4415
Phone CeII Phone
Valuation:
Total Sq Feet:
$ 2,264.00
0
Type of Work: REPLACE 1 WINDOWS
No of Openings: 1
Additional Info:
Classification: Residential
Scanning: 3
Fees Due
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee
Scanning Fee
Technology Fee
Total:
Amount
$1.80
$2.00
$2.00
$0.60
$110.00
$9.00
$2.40
$127.80
Pay Date Pay Type Amt Paid Amt Due
Invoice # WS-7-18-68320
07/24/2018 Credit Card $ 50.00 $ 77.80
08/03/2018 Credit Card $ 77.80 $ 0.00
Available Inspections:
Inspection Type:
Final
Window Door Attachment
Review Building
In consideration of the issu.n.- to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in stri,' onformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I ass 1 - responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRIC L,i-��MBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT r I '%ify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zhorize the above -named contractor to do the work stated.
2_
Authorized Signature: Owner /
Applicant / Contractor / Agent
August 03, 2018
Date
Building Department Copy
August 03, 2018 1
BUILDING
PERMIT APPLICATION
BUILDING ❑ ELECTRIC
❑PLUMBING ❑ MECHANICAL
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
RECEIVED
JUL 2 41018
,'F,B C 20 I�1
Master Permit No. J31 e —1 cil
Sub Permit No.
❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
JOB ADDRESS: 14c fUE ' 1 ()1 S
❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
City: Miami Shores
Zip: ig�
Foilo/ParceIN: )1 — 3 2 Q ( 013- 1 y y o Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone:
OWNER: Name (Fee Simple Titleholder): 1 a SAC ^t- V-t
Address: ) LI k) 1 () (
City: t CA 1N11 SVinte3
Tenant/Lessee Name: N/A
Email: N/A
State: L
BFE: FFE:
Phone#:
Zip: ? 13g
Phone#: N/A
CONTRACTOR: Company Name: FLORIDA HOME IMPROVEMENT
Address: 4070 SW 30 AVE
City: HOLLYWOOD
Qualifier Name: WAYNE T. BURNETT
State Certification or Registration #: CGC061890
DESIGNER: Architect/Engineer: NIA
Address: NIA
Phone#: 954-7924415 Ix 334
Zip: 33312
Phone#:
Certificate of Competency #:
Phone#: N/A
aty: N/A
Value of Work for this Permit: $ 7Z(„(--1
Square/Unear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration El New IIII Repair/Replace
Description of Work: REPLACE ) ._ K\ A0,0
State: N/A zip: N/A
❑ Demolition
Specify color of color thru tile:
Submittal Fee $ S v pcl 6 Permit Fee $
Scanning Fee $ 1
County: Miami Dade
State: FL
Radon Fee $ Z.
Technology Fee $ Z' • 4to Training/Education Fee $
Structural Reviews $ C'S1
(Revised02/24/2014)
110 • try. CCF $ • & O CO/CC $
DBPR $ 2 Notary
0 ' b0 Double Fee $
Bond $
TOTAL FEE NOW DUE $ T 7 . 8o
Bonding Company's Name (if applicable) N/A
Bonding Company's Address N/A
City N/A state N/A
Mortgage Lender's Name (if applicable) N/A
Mortgage Lender's Address N/A
zip N/A
City N/A State NIA Zip N/A
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'SAFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO'OBTAIN FINANCING, CONSULT WITH YOUR. LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice"to Applicant: As a condition to the issuance of a building permit with an istlmated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the firstinspection which occurs seven (7) days after the building permit is Issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee wil! be charged.
Signature
OWNER or ,Q T
The foregoing instrument as acknowledged before me this
I day of � ,20 I,by
53 \ `�� � , wh is personally known to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
Lito el Kr? :itifIL�CLf�'�pi�r3'f1l
• iR MY COMMISSION ii FF 164915
EXPIRES: October 1, 2918
ss*s**s*ss*ss*ss*s*****s**s*******fir*s*** ***************************************e**********************
j2Ji/'
as
APPROVED BY
(Revised02/24/2014)
Signatur
RACTOR
The foregoing instrument was acknowledged before me this
I dayof A---) ,20 S by
-
YJ y I , whol personallykown to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
L1
Print: M
Seal:
as
Plans Examiner
Structural Review
Zoning
Clerk
Florida Home Improvement Associates
License No. CGC 0618901 QB44818
3044 SW 42nd SL, Ft. Lauderdale, FL 33312
Job# (6-7-
FLORIDA
HOME
IMPROVEMENT
ASSOCIATES
Replacement Windows Contract
Broward Tel: 954-792-4415
Miami Dade Tel: 305-545-4469
Fax: 954.792-2170
Web: FHAPRODUCTS.COM
Email: INFOQFHAPRODUCTS.COM
t
Name: P / / �f% Home Phone:? OF3 9f.1 Bus. Phone:
d'4 /cV9t
Address
4401, c C4 S,-t /A -
City State
This Contract is made anipntered into this r day of-JLi ii ' 2Q/ and between Florida Home -Improvement Associates, Inc,
a Florida corporation ("Contractor" or "FHA"), and owner(s) named above of the residence located at the address listed above ("Owner").
The Work. Contractor agrees to perform the work described below:
1) Remove existing units to be replaced. (NOTE: Removed items are likely to be damaged.)
2) Prepare openings as necessary to receive replacement units.
3) WINDOWS: 'FHA Energy Storm Saver Simonton Vinyl Insulated
Install Aluminum Insulated Aluminum Non -Insulated
4) Doors: FHA Energy Storm Saver _ Aluminum Insulated, Aluminum Non -Insulated
Zip
Directions are viewed from the inside.
On sliding glass doors Active and Fixed
Panels are Identified. On Casements
and single French doors the hinge is
Identified Right Hinge and Left Hinge.
On Double -French Doors the more
active door is identified
Impact( yam} Non -Impact: ( ) Color: White: %C.- Tan: Bronze: Grey: Mill Finish:
poubk Hung
OW_
ACTIVE
ACTIVE
Single Hung
QtYL
FIXED
ACTIVE
SRdlna Glass Door
AA AF FA FAAF AAF FAA
Qty Qty Qty Qty QtY CRY
7LR
Qty_
FA
AF
Casement
Qty_
RH
;Ingle French Doors
RH( ) LH( )
Qty_
Glass: /10 »i, ref s% 4' %ngs
Warranty: Manufacturer's Warranty sent u0gn cQmpen.
5) Work NOT to be replaced:PA./4' 04 4V4e
AC
picture Window
Qty
0J
Double French Doors
RA( 1 L )
Qty_
Geometric
Qty_
Other
Qty—
INITIAL HERE •3
INITIAL HERE-)
7) Special Instructions: 4-W
6) If applicable, removing %`shutter pa I nd/or security Al
pi!•e e�/
y
INITIAL HERE-)
8) Cleanup job debris and providenecessary permits and insurance.
9) If applicable, In the event that Contractor Is unable for whatever reason to obtain proper permits prior to commencement of any work,
Contractor shall refund any previous payment and this transaction shall be automatically cancelled.
(No finish wogther `� no�s�Tson is to be done unless noted below.)
Additional Work: '��``ll���.•�r.•.• �Cra�
ecv
Schedule: Contractor shall commence the work within 10days after execution of the Contract (the "Commencement Date") and shall endeavor to
complete all Work hereunder within ) days after the Commencement Date.
Contract Pr ')
The TOTAL PRICE for all Labor and Materials (including any applicable discount) is $�(i �`i —�i � .l')0 Sales Tax ( '4 t) $
Down Payment $
ZZ r (if applicable)
Balance Payable $ ' -oo Total Contract Price $_
Contractor will provide to Owner a Final Waiver and Release of Lien and Contractor's Fina A •avit to Owner, substantially similar to the forms
included in chanter 713. Florida Statues (20051.
Circle one: (YES or NQwner elects to apply for financing of the above -statue lump sum amount. If yes is circled, see financing agreement
and related documents
Notice to the Owner, If finandng ls being obtained by Owner:
a). Do not sign this home Improvement contract (including. flnandng documents) In blank.
b). You are entitled to a copy of the contract at the time you sign. Keep it to protect your legal rights.
c). The finandal documents attached to thls home Improvement contract may contain a mortgage or otherwise create a lien on your property that could be foreclosed
on H you do not pay. Be sun you understand all provisions of the contract and financial documents before you sign.
Miscellaneous: This contract contains the entire contract of the parties. It may not be changed orally but only by a signed change order or other
written amendment. The waiver by any party of a breach of any provision of this contract shall not operate or be construed as a waiver of any
subsequent breach by any party.
IN WITNESS WHEREOF, the Parties hereto have executed this contract, under seal, as of the day and year first above written.
You the Buyer may cancel thls transaction at any time prior to midnight on the third business day after the date of this transaction.
See the att>ifhed notice pf cancellation form for an explanation of this right.
can�te,.rr::
Signatu7e of Ow
(Signature of Owner)
Con
By:
(Name & Title)
ll
Date
Home Owners Association Name: Phone#:
YES ( ) NCj Betiding Name:
Miami Shores ViHage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Inspection requirements for.
Windows, Doors, Skylights or Fixed Glass (cladding) Permits
Upon issuance of permits for the scope of work involving the removal, changing and/or
replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding)
the permit holder or qualifier bearing his signature on the permit application shall abide
by the requirements of this department and comply with the following statement:
Upon obtaining window and/or door permits for the installation of same, it is the
responsibility of the permit holder to request window/door framing in -progress
inspection, prior to concealment of any horizontal or vertical dip mullion, bucks, shims,
etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The
purpose for this inspection, is for the verification of conformance with Product
Approval (NOA).
Qualifier/Owner Signature Date
Uscef' C o-nza(oz-K-ea.-f lY
Print Name
Property Search Application - Miami -Dade County
OFFICE
OFHE PROPERTY APPRAISER
ra•r.iii
xi•
Summary Report
Property Information
Folio:
11-3206-013-1940
Property Address:
145 NE 101 ST
Miami Shores, FL 33138-2320
Owner
PHILIP R KEATING
LISSET GONZALEZ KEATING
Mailing Address
145 NE 101 STREET
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds/Baths/Half
2/1/0
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
1,682 Sq.Ft
Lot Size
8,625 Sq.Ft
Year Built
1935
Assessment Information
Year
2018
2017
2016
Land Value
$215,711
$215,711
$215,711
Building Value
$154,841
$156,793
$158,743
XF Value
$32,033
$32,402
$32,770
Market Value
$402,585
$404,906
$407,224
Assessed Value
$402,585
$404,906
$407,224
Benefits Information
Benefit
Type
2018
2017
2016
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
MIAMI SHORES SEC 1 AMD PB 10-70
LOT 20 & E1/2 LOT 19 BLK 14
LOT SIZE 75.000 X 115
OR 20004-1675 10 2001 1
COC 23703-0054 08 2005 1
Page 1 of 1
Generated On : 7/2/2018
Taxable Value Information
2018
2017
2016
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$352,585
$354,906
$357,224
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$377,585
$379,906
$382,224
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$352,585
$354,906
$357,224
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$352,585
$354,906
$357,224
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
03/18/2015
$550,000
29548-3550
Qual by exam of deed
08/01/2005
$680,000
23703-0054
Sales which are qualified
10/01/2001
$250,000
20004-1675
Sales which are qualified
11/01/1997
$150,000
17874-1107
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
https://www.miamidade.gov/propertysearch/
7/2/2018
P : = q h • (GCp - GCp i)
V (mph) 175 1620 FBC for 1HV117 or Fig. 26.5-le
Risk Category II Table 1.5-1, page 2
Exposure C Section 26.7
Krl 0.85 Table 26.6-1, page 250
Kit 1 Figure 26.8-I, page 252
GCp 0.18 -0.18 0.55
pitch of roof 3/12 14.0 Regrets
them 14.0 degas
Mean
tight
Specialty Engineering Consultants. Inc.
1599 SW 30 Avenue, Suite #20
Boynton Beach, FL 334326
FL. CA # 009217
Intstuctions and limitations of Use
Wind Velocites in South Florida
-
Dade
Broward
Pale, Beach
Risk Cat. 1 a165
156
156
Low risk t
Risk Cal. 2
175
170
170
Singl
Risk Cat.7&4
ltl6
1tl0
180
as
o human � � ,•
c Family
satlial F ! .
2
3
4
5
8
7
10
12
Charts provide wind pressures based on the mean roof height. And shall not exceed 60'-0'.
Design pressures are for an enclosed builinding (shutters or other impact resistance protection required).
User shall determine the mean roof height, (Eave height * Roof Peak)/2.
End zone distance is the lessor of 10% of length, 10% of width, or 40% of the mean roof height and not less than 3'-0"
If 50% of a component is in a particular zone then that component is considered to be in zone with the majority of the area. If questionable then place in Zone 5
Each component, window, door, mullion has a tributary area that is area to be used. Area of components to rounded down but shall not be less than 10 sf.
For NOA's that require a Kd=1.0 then multiply the values listed herein by 1.18.
Wind pressures are based on Allowable stress design.
Design pressures listed herein are valid for Exposures B and C and exposure D. (max roof height 30')
Charts and values listed herein are only valid when signed, dated, and sealed by Gary McDougle, PE #56214 or Mark LeBlanc, PE #35683 or Adam D. LeBlanc, PE#77012
Wind design pressures are calculated in accordance with ASCE 7-10, Method 2. This calculation a vaild for FBC 2014 (5th edition) and 2017 (6th edition)
No reduction is taken for slopes less than 10 degrees.
Area ofcomponaa
Arne of component
15.0 sf
Arca ofcomponart
200 sf
Arca of component
25.0 sf
Arne of component
300 sf
Arca of component
35.0 sf
Area of compooaa
40.0 sf
Arm of componaa
45.0 sf
Ann of compona,l
50.0 sf
Arca of component
55.0 sf
Arai of eomponcet
60.0 sf
Zone 4
40.1
-43.4
40.6
-44.0
Zone 5
40.1
-53.6
40.6
-54.4
Zone 4
8.8
42.2
39.3
-42.8
Zone 5
38.8
-51.3
39.3
-52.0
Zone 4
38.4
-41.8
38.9
-42.4
Zone 5
38.4
-50.6
38.9
-51.3
Zone 4
37.9
-41.4
38.4
-42.0
Zone 5
37.9
-49.8
38.4
-50.5
Zone 4
37.5
-41.0
38.0
-41.6
Zone 5
37.5
-49.0
38.0
-49.7
Zone 4
37.1
-40.6
37.6
-41.1
Zone 5
37.1
-48.3
37.6
-48.9
Zone 4
36.7
-40.2
37.2
-40.7
Zone 5
36.7
-47.5
37.2
-48.2
Zone 4
36.2
-39.8
36.7
-40.3
Zone 5
36.2
-46.8
36.7
-47.4
Zone 4
35.8
-39.4
36.3
-39.9
Zone 5
35.8
-46.0
36.3
-46.6
Zone 4
35.4
-39.0
35.9
-39.5
Zone 5
35.4
-45.2
35.9
-45.8
Zone 4
35.0
-38.6
35.4
-39.1
Zone 5
35.0
-44.5
35.4
-45.1
17
41.1
-44.6
41.1
-55.1
39.8
-43.4
39.8
-52.7
39.4
-42.9
39.4
-51.9
38.9
-42.5
38.9
-51.1
38.5
-42.1
38.5
-50.4
38.1
-41.7
38.1
-49.6
37.6
-41.3
37.6
-48.8
37.2
-40.8
37.2
-48.0
36.8
-40.4
36.8
-47.2
36.3
-40.0
36.3
-46.4
35.9
-39.6
35.9
-45.7
18
41.6
-45.1
41.6
-55.7
40.3
-43.9
40.3
-53.3
39.9
-43.5
39.9
-52.6
39.4
-43.0
39.4
-51.8
39.0
-42.6
39.0
-51.0
38.5
-42.2
38.5
-50.2
38.1
-41.8
38.1
-49.4
37.7
-41.3
37.7
-48.6
37.2
-40.9
37.2
-47.8
36.8
-40.5
36.8
-47.0
36.3
-40.1
36.3
-46.2
19
42.1
-45.7
42.1
-56.4
40.8
-44.4
40.8
-54.0
40.3
-43.9
40.3
-53.2
39.9
-43.5
39.9
-52.4
39.4
-43.1
39.4
-51.5
39.0
-42.7
39.0
-50.7
38.5
-42.2
38.5
-49.9
38.1
-41.8
38.1
-49.1
37.6
-41.4
37.6
-48.3
37.2
-41.0
37.2
-47.5
36.7
-40.5
36.7
-46.7
20
42.6
-46.2
42.6
-57.0
41.2
-44.9
41.2
-54.5
40.7
-44.4
40.7
-53.7
40.3
-44.0
40.3
-52.9
39.8
-43.6
39.8
-52.1
39.4
-43.1
39.4
-51.3
38.9
-42.7
38.9
-50.5
38.5
-42.3
38.5
-49.7
38.0
-41.8
38.0
-48.9
37.6
-41.4
37.6
-48.1
37.1
-41.0
37.1
-47.2
21
43.0
-46.6
43.0
-57.6
41.6
-45.3
41.6
-55.1
41.2
-44.9
41.2
-54.3
40.7
-44.4
40.7
-53.5
40.3
-44.0
40.3
-52.6
39.8
-43.6
39.8
-51.8
39.3
-43.1
39.3
-51.0
38.9
-42.7
38.9
-50.2
38.4
-42.3
38.4
-49.4
38.0
-41.8
38.0
-48.5
37.5
-41.4
37.5
-47.7
22
43.4
-47.1
43.4
-58.1
42.0
-45.8
42.0
-55.6
41.6
-45.3
41.6
-54.8
41.1
-44.9
41.1
-54.0
40.7
-44.4
40.7
-53.2
40.2
-44.0
40.2
-52.3
39.7
-43.6
39.7
-51.5
39.3
-43.1
39.3
-50.7
38.8
-42.7
38.8
-49.9
38.4
-42.2
38.4
-49.0
37.9
-41.8
37.9
-48.2
23
43.8
-47.5
43.8
-58.7
42.4
-46.2
42.4
-56.2
42.0
-45.8
42.0
-55.3
41.5
-45.3
41.5
-54.5
41.0
-44.9
41.0
-53.7
40.6
-44.4
40.6
-52.8
40.1
-44.0
40.1
-52.0
39.6
-43.5
39.6
-51.2
39.2
-43.1
39.2
-50.3
38.7
-42.6
38.7
-49.5
38.3
-42.2
38.3
-48.7
24
44.2
-48.0
44.2
-59.2
42.8
-46.6
42.8
-56.7
42.3
-46.2
42.3
-55.8
41.9
-45.7
41.9
-55.0
41.4
-45.3
41.4
40.9
-44.8
40.9
40.5
40.5
-52.5
40.0
40.0
-51.6
39.5
-43.5
39.5
-50.8
39.1
-43.0
39.1
-49.9
38.6
-42.6
38.6
-49.1
25
44.6
-48.4
44.6
-59.7
43.2
-47.0
43.2
-57.2
42.7
-46.6
42.7
-56.3
42.2
42.2
-55.5
41.8
41.8
-54.6
41.3
-45.2
41.3
-53.8
40.8
-44.7
40.8
-52.9
40.3
40.3
39.9
-43.8
39.9
-51.2
39.4
-43.4
39.4
-50.4
38.9
-42.9
38.9
-49.5
26
45.0
-48.8
45.0
-60.2
43.5
43.5
-57.6
43.1
-47.0
43.1
-56.8
42.6
-46.5
42.6
-55.9
42.1
-46.0
42.1
-55.1
41.6
-45.6
41.6
-54.2
41.2
41.2
-53.4
40.7
-44.7
40.7
-52.5
40.2
-44.2
40.2
-51.6
39.7
-43.7
39.7
39.3
39.3
-49.9
45.3
45.3
43.9
43.9
43.4
-47.3
43.4
-57.2
42.9
-46.9
42.9
-56.4
42.4
-46.4
42.4
42.0
42.0
-54.6
41.5
41.5
41.0
-45.0
41.0
-52.9
40.5
-44.6
40.5
-52.0
40.0
-44.1
40.0
-51.2
39.6
-43.6
39.6
-50.3
4511
46.3 46.3
ZONING DEPT
44.2
-48.2
44.9
44.2
-58.5
44.9
-59.4
43.7
-47.7
44.4
43.7
-57.7
44.4
SUBJECT TO COMPLIANCE VVI frH ALL FEDERAL
1.2
7.9
43.3
-56.8
43.6
-57.2
43:9
-57.6
42.8
-46.8
43.1
43.4
-47.4
42.8
-55.9
43.1
43.4
-56.8
42.3
-46.3
42.6
-46.6
42.9
-47.0
IPA
41-55.1
92.6
42.9
-55.9
42.4
-46.5
42.4
-55.0
041,
41.9
-46.0
• 41.6
41.9
40.8
41.1
-45.2
41.4
-45.6
40.8
-52.4
41.1
-52.8
41.4
-53.2
40.4
-44.4
40.7
-44.8
OF
x•
S
00
N
Lf)
CJ1
00
1.0
2
be
• ••• • • • •••
• •• • • •• • •• •• •
• • •• ••
• •
• ••• • • •
1-•
1•S
•
• ••• • • • • •••
• ••• • • • •
• • •••• ••• •
• •
•• • • • •• • • • •
• • ••• • ••• •
• • •• •• • •••
• • •••• •• •••• •
•
•• • • • •• ••• ••
•
• • • •
• • •
•
• • • • • • • • • • • •
�. 0
4.d
FAMILY
LAUNDRY
.• k
KIT
4) LOFT
SD GARAGE.
a •'3
DINING
ENTRY.
?•a
2.•
BED
BATH
sit
iecl i
2.v
oo
BATH
BED
14•�
Y• •
6•0
38 X 58 1 /4
(+/-70)
FL 16177.1
1/4/2018
Florida Building Code Online
riFlorida
Y=444,:press
/ OFFICE OF,TTHHE
SECRETARY.
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
Product Approval
USER: Public User
Product Approval Mere' > product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
FL16177-R2
Revision
2017
Approved
0
Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext 245
kpine@cws.cc
Authorized Signature
Kevin Pine
kpine@cws.cc
• • • •
• •
• • • • • •
• • • •
•• • • • • • •
• • •
••
•
• • • • •• •
• • • • •
• • • • • ••
• • • •
•
• •
• • •
•• •• • • • •
•
• •
• . • •
• • •
Technical Representative Jay Lathrop • • • • •
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Arturo Monteverde
1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 221
amonteverde@cws.cc
• • •
•• • •• • • •
• • •
•• •
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lucas A. Turner
Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M. Urich, PE
Rai Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL16177 R2 COI EvalReport812C.Ddf
Standard Yea[
AAMA/WDMA/CSA/101/I.S.2/A440-08 2008
ASTM E1886-05 2005
ASTM E1996-09 2009
PA TAS 201/202/203 1994
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh10y8QtjDbmBlPrafAGHlxlsgtjUObEAbzoQ%3d%3d 1/2
1/4/2018 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
09/28/2017
09/29/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16177.1
SH-8100 PVC Single Hung
SH-8100 PVC Single Hung Impact Resistant window.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: SH-8100 PVC Impact, no sill anchors required. Safety
glazing required on outer lite above 30 ft. in HVHZ. Glass
complies to ASTM E1300-04.
Installation Instructions
FL16177 R2 II CWS-812C.Ddf • •' •
'
•
•
•
••
Verified By: Lucas A. Turner 58201 • • • •
Created by Independent TRi;c arjy: Yes ... .
Evaluation Reports • •
FL16177 R2 AE EvalReoorf% ie.odf
Created by Independent TItird'IPer y: Yes '
.•.. • • •
• • •
Back
Next
• • • •
• •
•• • •
• ••
• • • •
•
• • • •
•
• • •
• • • •
•
•
•
• •
•
••
Contact 114 :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-V24 • • • •
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida :: privacy Statement :: AgLessilrility Statement :: peltundiStatement•
• • •
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records reques?,4o riot send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emaits provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here
Product Approval Accepts:
i 7.•� eCheck
Credit Card
Safe
sccuritv.IElRICs'
•
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyMngAXh10y8QtjDbmBlPrafAGHlxlsgtjUObE4bzoQ%3d%3d 2/2
URNER
ENGINEERING &
CONSULTING, INC.
1239 Jabara Ave.
North Port, FL 34288
Ph. 941-380-1574
FBPE C.O.A. #29779
Evaluation Report 812C
August 29, 2017
Product Description: Series 8100 PVC Single Hung, Large Missile Impact, 51 7/8" x 61 3/4" unit size,
+/-70 PSF, no anchors in sill
Manufacturer: Custom Window Systems, Inc. 1900 SW 44th Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The producteSttiig
standards performed are outlined below. • • • • • • • •
••• • ••• •
••
••
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Po4.M
2) Approval drawing CWS-812C, signed and sealed by Lucas A. Turner, P.E. • • • •
3) Test Report NCTL-210-3815-1A, -2, and -2A, by National Certified TestingTesting l'411datories,
Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed:•11S 201/2a.7!03-
94, ASTM E 1886-02/04/05, 1996-02/04/06/09, and AAMA/WDMA/CSA 1 Q 1 /I! S 2/A440-08•
4) Supplemental Calculations to support CWS-812C, signed and sealed by Lucas A.:turner; PT"
• • •
•
•• •
Installation: Units must be installed according to approval document CWS-812C.
•• -
• • • -
•
Limitations of Use: This product:
• May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS-
812C
• Is impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• Requires 7/8" Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite (Tempered
required above 30 ft in HVHZ) — Air — 5/16 Laminated (1/8Ann-.090PVB-1/8Ann) inboard lite
• Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.02t
• Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.10t
t I have evaluated the materials in these NOAs and find that they comply with the requirements of the
6th Ed. (2017) Florida Building Code for use in this product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a fmancial interest
in any other entity involved in the testing or approval process of this product.
Lucas
Turner
2017-08-30
16:11+20:00
:0:::`k,,ivocREWs if 1.
-., . No 58201 : I)
= *: * • =• * = /%
�-o: : a'c"
r9 S,STATE OF ��
,� ., 0 R , �, : 8/29/2017
�'�i�s' �..,•,..�•'`ca .• Lucas A. Turner P.E.
#'116i3;04XCS.;40•%% FL PE #58201
SINGLE HUNG - LARGE MISSILE IMPACT
53 1/8" MAX. OVERALL FLANGE WIDTH
51 7/8" MAX. UNIT WIDTH
47 11/16' GLASS DLO
A
63"
MAX.
OVERALL
FLANGE
HEIGHT
61 3/4"
MAX.
UNIT
HEIGHT
26 13/16"
GLASS
DLO
30 3/16"
MAX
SASH
HEIGHT
X
26 7/8"
GLASS
DLO
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS 1
GLAZING DETAIL 2
SECTION VIEWS 3
EXTRUSIONS & B.O.M 4
ANCHOR SCHEDULE & NOTES 5
INSTALLATION DETAILS 6
45 1/16"
GLASS DLO
A
48 3/8"
MAX. SASH WIDTH
•
•
GENERAL NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED
TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED
IN ASTM E 1996 PER THE FBC.
2. GLAZING OPTIONS: (SEE SHEET 2)
3. CONFIGURATIONS: "O/X".
4. DESIGN PRESSURE RATING:
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E-1300-04e01/09.
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES
ASTM E-1300-04e01/09.
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
ANCHOR CALCULATIONS.
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE
NOT REQUIRED.
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
USED AT FIXED MEETING RAIL AND JAMB.
8. SERIES / MODEL DESIGNATION SH-8100.
9. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING:
X = OPERABLE SASH, 0 = FIXED SASH
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR
LOCATION.
11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS.
• • • • • • • • • • • •
• •
• •
• •
•
•• ••• •• • • • ••
•
• •
MAX.IT SIZE
DESIGN PRESSURE
RATING
.•. IMPACT WING. •.
• • ...
51-7/8" x 61-3/4"
+/- 70 PSF
LARGE MISSILE IMPACT
1100 • • • • • •
• •
• •
•
• • • •.. • • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
LucasTurne
r
2017-09-22
13:36-04:00
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.0 W S.CC
8100 PVC
SINGLE HUNG
IMPACT
PROPRIETARY AND CONFIDENTIAL
........... RE rip,
.4. . • 'C ENS'Q''.•4t ti : " NO 58201 :111
* * ; * E
O: STATE OF •CV4
"1S,ONA ,. i.%••%
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
GENERAL NOTES AND
ELEVATIONS
DRAWN BY:
BAT
DATE:
06/18/12
DWG#: REV.:
CWS-812 C
SCALE
1:15
SHEET
1 OF 6
7/8" OVERALL INSULATED GLASS
1/8" ANNEALED OR TEMPERED
7/16" AIRSPACE
5/16" LAMINATED GLASS
1/8" ANNEALED
.090" PVB INTERLAYER BY DUPONT
1/8" ANNEALED
QUANEX DURASEAL
IG SPACER
PURFECT GLAZE "H" OR SIKAFLEX 552
1/2" GLASS BITE
7/8" OVERALL INSULATED GLASS
1/8" ANNEALED OR TEMPERED
7/16" AIRSPACE
5/16" LAMINATED GLASS
1/8" ANNEALED
.090" PVB INTERLAYER BY DUPONT
�1/8" ANNEALED
QUANEX DURASEAL
IG SPACER
PURFECT GLAZE "H" OR SIKAFLEX 552
1/2" GLASS BITE
•• ••• • • • • • ••
•
•• •
• •
•
•• •••
•
•
•• • • • ••
• ••• • ••• • •
• • • • • • • •
• • • ••• • • • •
• • • • • • • • • •
• • •• • • • • • •
• • • • ••• •
••• • • • • ••• • •
r SETTING BLOCKS PER FBC 2411.3.3.11
aattOnn
rWINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8100 PVC
SINGLE HUNG
IMPACT
PROPRIETARY AND CONFIDENTIAL
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
GLAZING DETAILS
DRAWN BY:
BAT
DATE:
06/18/12
DWG#:
CWS-812
SCALE:
1:1
REV.:
C
SHEET
2 OF 6
• • • ••• • • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
INTERIOR
SECTION A -A
NOTE: ITEMS NOT SHOWN FOR CLARITY:
20, 25-26, 36-37, 44, 51-52, 55-56, 64, 67-68
INTERIOR
SECTION B-B
NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW,
RIGHT SIDE SHOWS SASH SECTION VIEW.
•• ••• • • • • • ••
•
• • •
• • • •
•
•• ••• •• • • • ••
• • • • • • • • • •
• • • • • • • •
• • • • • • • • • •
• • • • • • • • • •
• • •• • • • • • •
• • • • • • • •
• • • • • • • • • • • •
• • • • • • • •
• • • • • • • • •
• • • • •
• •• •• • • • •• ••
0•• • • • 0•• • •
c_111 r
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8100 PVC
SINGLE HUNG
IMPACT
PROPRIETARY AND CONFIDENTIAL
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
SECTION VIEWS
DRAWN BY:
BAT
DATE:
06/18/12
DWG REV.:
CWS-812 C
SCALE:
1:2
SHEET
3 OF 6
PARTS LIST
ITEM
PARTN
DESCRIPTION
VENDOR
MATERIAL
1
H-6031
Main Fr., SH, w/Flg., PVC, Head
Mikron
Vinyl
2
H-6031
Main Fr., SH, w/Flg., PVC, Sill
Mikron
Vinyl
3
H-6031
Main Fr., SH, w/Flg., PVC, L. Jb.
Mikron
Vinyl
4
H-6031
Main Fr., SH, w/Flg., PVC, R. Jb.
Mikron
Vinyl
6
S-1577
Impact Hook
Keymark
Alum
8
H-6027
Sash Meet. Rail, PVC
Mikron
Vinyl
9
H-1497
Reinf. Sash Meet. Rail
Keymark
Alum
10
H-6028
Sash Bottom Rail, PVC
Mikron
Vinyl
12
H-6004
Sash Side/Top/Bot. Rail
Mikron
Vinyl
13
S-1498
Reinf. S.B.R./S.S.R
14
S-6064
Glz. Bd., 7/8"
Mikron
Vinyl
18
S-6013
Scm. Adapt., w/Nib, PVC, Horiz.
Mikron
Vinyl
19
S-6014
Scm. Adapt., PVC, Vert.
Mikron
Vinyl
20
S-6029
Sash Stop / Filler, PVC, Vert.
Mikron
Vinyl
23
H-1699
Reinforcement, SBR
Keymark
Alum
24
P-2190
Balance
BSI
25
P-3059
Sash Cam, PVC
BSI
Plastic
26
P-3046
Take Out Clip
BSI
SS
27
P-3783
Lock, Impact, PVC
hterlock
28
P-069
Keeper, Impact, PVC
Interlock
Zamac
30
P-3215
Weep Cover w/ Flap
Geer
Plastic
32
P-3429
Wstp., 0.270 x .187 back FinSeal, Gray
Ultrafab
37
P-4638
#8 x 2-1/2 PH Mod. Truss, Type A, TEK 2
Fastenal
Steel
38
P-3768
#8 x 0.625 Ph PH SMS
Hub City
Steel
39
P-4051W
#8 x 1.250 Ph FH TEK, Wht.
Hub City
Steel
40
P-4264W
#8 x 3/4 FH PH w/#6 Head, TEK, Wht.
Hub City
Steel
44
P-3342
Seam Sealer, SM-5504
Schnee
45
P-3752
Cap Plug, 1/2" Hole
M&M
Nylon
47
P-3438
Sikaflex 552 or Purfect Glaze "H"
Sika/Henkel
48
P-3352
Set. Blk., 85 Dur., 1/8" x 5/8" x 2" Lg.
F. Lowe
Rubber
51
P-3881
Temporary Lbl. (NFRC/DP)
52
P-3613
CWS Lbl. (logo)
Pro Label
53
Sash
SEE SHEET2
GLASS
54
Fixed
SEE SHEET2
GLASS
56
P-3281
Spacer
Duraseal
62
P-3218
Screen Frame, Horiz.
Allmetal
Alum
63
P-3218
Screen Frame, Vert.
Allmetal
Alum
64
P-3321
Screen Frame Corner Key
Allmetal
Plastic
65
P-3581
Screen Cloth, 18 x 16 Fiberglass
Betterue
Fiberglass
66
P-3228
Screen Spline, .155 Dia., Blk.
Dapa
Vinyl
67
P-3029
Screen Pull Tab
Summit
Alum
68
P-3033
Screen Spring, SS
FI. Screen
SS
70
P-3113
Screw Support for PVC
T. Plastics
Nylon
71
H-1836
Alum. Fixed Rail
Keymark
Alum
72
S-6063
Cover, Fixed Rail
Mikron
Vinyl
73
S-1112
Reinforcement, Impact Hook
Keymark
Alum
74
P-3541
#8 x 1/2", Pan Head, TEK
Fastenal
Steel
LINE ITEMS NOT USED:
5, 7, 11, 15-17, 21-22, 29, 31, 33-36, 41-43, 46, 49-50, 55, 57-61, 69
NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
PVC FRAME FLANGE-6031
REINF., IMPACT HOOK - 1112
PVC SASH STOP - 6025
3/4"
1/16"
REINF. S.B.R./S.S.R. - 1498
0 3/16"
IMPACT HOOK
S-1577
PVC SASH BTM. RAIL-6028
1 3/16"
1 5/8"
1/16"
PVC SASH SIDE RAIL - 6004
/2" ' 1 1/8"'
1/16"
PVC SCREEN CATCH - 6013
REINF. BTM RAIL-1699
♦•�:rJ
PVC SASH TOP RAIL-6027
FIXED RAIL - 1836
9/16"
1 5/16"
045"
PVC FIXED RAIL COVER - 6063
5/8"
1" J��LJ
1/16"
FRAME CORNER
CONSTRUCTION
WINDOW SYSTEMS
r
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
CORNER WELD
(ALL SIDES)
1:8
FIXED MEETING RAIL
SCREWED TOGETHER WITH
OUTERFRAME
1:8
8100 PVC
SINGLE HUNG
IMPACT
5/16'
PVC SCREEN SUPPORT - 6014
REINF. TOP RAIL-1497 PVC GLAZING BEAD-6064
• • • • ••
•
• •• •
•• • • • ••
• • ••• •
• a • • •
• • • 1/t•
5" �{ 3/16" T
IIh I 3"
••• 4.:
Try
• • •T • SCREW SUPPORT-3113
• • • • • • • • •
•• • • • • • •
• • • • • • • •
• • • •
a • •
• • •
• •
• • • • • • • • • • • •
• • . • . . —s
• • • • • • • • •
• • • • •
• •• •• • • • •• ••
• • • • • • • • • • •
PROPRIETARY AND CONFIDENTIAL
,,,,PtsORE W ,T,,ii
C E N eF 9.PI:S
JNo 58201 :Ii1
0: STATE OF
•:,:7UjU
" %.":4 o R O P,.\`J
SfONA 1�a`,`�
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
BOM AND EXTRUSIONS
DRAWN BY:
BAT
DWG N:
CWS-812
SCALE:
1:2
DATE.
06/18/12
REV.:
C
SHEET
4 OF 6
6" MAX. (TYP.)
6" MAX. (TYP.)-
4" (TYP.)
17" MAX. O.C. (TYP.)
10 1/2"
MAX. O.C.
(TYR)
10 1/2"
MAX. O.C.
(TYR)
4" (TYP.)-
4" (TYP.)
0
X
NO ANCHORS REQUIRED IN SILL
ANCHOR LAYOUT - (FLANGE)
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. NO ANCHORS REQUIRED IN SILL.
SEE NOTE 2
INSTALLATION
ANCHOR (TYP.)
MTG RAL
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST
BE PROTECTED TO PREVENT REACTION.
•• ••• • • • • • ••
• • • • • • • • •
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BEUS11D Ml S1/1B9TRRTES WITH STRENGTHS LESS THAN THE MINIMUM
SPECIFIED IN TABLE 1, SHEET 6. • • • • • • • • • • •
•
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
• ••• • ••• • •
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD ANDIAETAIL. • • • • •
• • • ••• • a • ee
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGIN OF R �OF b A�VDINSTALI.ECITCORANIFE�c WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASON Y BSTIRATES MAYi1OT DE CRACY(6L• •
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS)
••• • • • • ••• • •
• a • • • • it
• • • ••• • • •
• • •
• •
• •• •• • a • •• ••
••• • • • ••• • •
C2150 tom
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8100 PVC
SINGLE HUNG
IMPACT
PROPRIETARY AND CONFIDENTIAL
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
ANCHOR SCHEDULE AND
NOTES
DRAWN BY:
BAT
DATE:
06/18/12
DWG 6: REV.:
CWS-812 C
SCALE
1:15
SHEET
5 OF 6
TYPICAL HEAD ANCHORAGE
SUBSTRATE BY OTHERS
SEE TABLE 1
PERIMETER SFAI ANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
INSTALLATION ANCHOR
SEE TABLE 1
SEALANT BEHIND
FLANGE BY INSTALLER
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SUBSTRATE BY OTHERS
SEE TABLE 1
MIN. EDGE DIST.
SEE TABLE 1
MIN. EMBEDMENT
SEE TABLE 1
CONTINUOUS DOUBLE 3/16" BEADS OF
TREMGLAZE U1600 SEALANT AROUND
PERIMETER AT ALL INDICATED POINTS
BETWEEN FRAME AND BUCK BY INSTALLER.
MIN. EMBEDMENT
SEE TABLE 1
MIN. EDGE DIST.
SEE TABLE 1
TABLE 1: APPRSVEDJNSTALLnTION FASTENERS
ANCHOR TYPE
MIN. EMBEDM
CONCRETE (2.0 KSI MIN.)
3/16" fTW TAPCON
1-1/2"
1-1/8"
HOLLO
1R" DW TAPCON
1"
---"--"7r
CONCRETE (2.85 KSI MIN.)
3/16" ELCO ULTRACON
1"
1"
GROUT -FILLED CMU (ASTM C-90)
3/16" ELCO ULTRACON
1-1/4"
2-1/2"
2X MIN. SOUTHERN PINE (G=0.55)
3/16' fTW TAPCON
OR ELCO ULTRACON
1-3/8"
7/8"
2XMIN. SOUTHERN PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
7/8"
16 GAUGE (0.060") MN. STEEL STUD
(33 KSI YELD MIN)
#10-16 HLTI KWK-FLEXOR RW
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.060"
7/16"
1/8" ALUM. (6063-T5 MIN.) OR
1/8" STEEL (33 KSI MIN.)
#10 GRADE 5 SELF -TAPPING /
DRLLING SCREW
FULL THREAD
THRU 0.125"
7/16"
SEE TABLE 1
MIN. EMBEDMENT
SEE TABLE 1
1/4" MAX SHIM
INSTALLATION„Pr
ANC OR '! P Hair
IN
SUBSTRATE
BY OTHERS
SEE TABLE 1
MIN. EDGE DIST.
SEE TABLE 1
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SFAI ANT BEHIND
FLANGE BY INSTALLER
BBii) HORIZONTAL SECTION
6 TYPICAL JAMB ANCHORAGE
•••Pdh TBCtsrn"y"•�
• BY IN AL -LW.
• NSI a 01411- • •
• • • • • •
•• ••• •• •
•
• •
• HORIZONTAL SECTION
BBRFRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
• FIANIGE RE♦41OVAI•NiOTE: PARTIALLY•OR FULLY REMOVING THE FLANGE,
• • UP•fO AND INCLUDINI A BOX -FRAME TPLICATION IS ACCEPTABLE PROVIDED:
• • • ••• •
• • • -SIN. 1/4"FIIALEI OG CONSITRUCT•ilOM-GRADE ADHESIVE CAULK IS APPLIED
• INSIDE ANDIOUTI•FULL PERIMETER, BY INSTALLER.
- PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
••• • • • •
• • • • •
• • • •••
• • • • • •
• •• •• • •
••• • • •
••• • •
• • •
• • •
• • • •
• •• ••
••• • •
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8100 PVC
SINGLE HUNG
IMPACT
PROPRIETARY AND CONFIDENTIAL
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTION:
INSTALLATION DETAILS
DRAWN BY:
BAT
DATE:
06/18/12
DWG
REV.:
CWS-812 C
SCALE
1:2
SHEET
6 OF 6