Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-18-107
Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Pe �m it Parcel Number Issue Date: 1/25/2018 Permit NO. I".F-1-18-1 O7 Permit Type: Roof Work Classification: Tile Pennit gtatus: APPROVED Expiration: 07/24/2018 Applicant 10618 NE 11 Avenue Miami Shores, FL 33138- 1122320280630 Block: Lot: BENJAMIN JOHN & KRISTINA R Owner Information Address Phone Cell BENJAMIN JOHN & KRISTINA ROGERS 10618 NE 11 Avenue - - - - -- MIAMI SHORES FL 33138- (786)390-8835 10618 NE 11 Avenue MIAMI SHORES FL 33138- Contractor(s) Phone THOMPSON'S ROOFING /J&T INVES1 (954)967-1918 CeII Phone Valuation: Total Sq Feet: $ 26,500.00 3317 Type of Work: Re Roof Additional Info: TILE RE -ROOF Classification: Residential Scanning: 4 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $16.20 $4.88 $3.25 $5.40 $325.00 $12.00 $21.60 $388.33 Pay Date Pay Type Invoice # RF-1-18-66126 01/16/2018 Check #: 1138 $ 50.00 $ 338.33 01/25/2018 Credit Card $ 338.33 $ 0.00 Amt Paid Amt Due Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is - .te and th- all w. rk will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -name • contract • to do a stated. Authorized Signature: Owner / Applicant / Con ract January 25, 2018 Date Building Department Copy January 25, 2018 1 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED JAV 1 6 ii018 BY;_ FBC 20!l Master Permit No. f(8 1 Sub Permit No. ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: /00/i /C. (/ / IVe17 J City: Folio/Parcel#: Miami Shores County: i Ua3cQ or Z 36 Occupancy Type(6 • Load: Construction Type: Miami Dade zip: .533/U Is the Building Historically Designated: Yes Flood Zone: BFE: NO FFE: OWNER: Name (Fee Simple Titleholder):) Sian')//) /</� S+;/1 Phone#: 37!) �d Address: / ,1�C/ / �" n/ / / IT1J'&i U City: / '/ ICE Am • ,i'l U(Vj State: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: / Y ll).1,. Address: /3lp d ()'-� Ki City: 3 U1 ? Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: Address: City: Value of Work for this Permit: $ Type of Work: Phone#: State: •—S 6 J1,1 11.01, 611 C ' (ir &.q p Y te7 Certificate of Competency #: Phone#: State: Zip: Phone#: Zip: 3%J Zip: _ Square/Linear Footage of Work: ❑ Additioy_ ElAlteration Description of Work: ❑ //-Q �P %21 ❑ Repair/Replace C3 Demolition Specify color of color thru tile: Submittal Fee $ Scanning Fee $ 1Z.- Permit Fee $ T CA CCF $ CO/CC $ 3 Radon Fee $ 3 • 25- DBPR $ ` Notary $ Technology Fee $ - i • ' D Training/Education Fee $ • `--1 Structural Reviews $ 57-9 7. Bond $ --d I • `(c% Double Fee $ (Revised02/24/2014) TOTAL FEE NOW DUE $ 339 33 ing Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to . ttachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection h occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be a ' . oved and a reins tion fee will be charged. Signature WNER or AGE T The foregoing instrument was acknowledged beforemethis 15 day of JO 1,1 q (� , 20 (o , by SQ m %/ C���s , who is personally known to me or who has produced `> $(IU'4S \i �'e'nSe— identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: as (1-1'%t a L AO n1, - CYNTH' • wileHELLE IERE MY COMMISSION # GG 166449 EXPIRES: December 17, 2021 :FORM1°. ss Bonded Mu Notary Public Undenwifers *************** Signat The foregoing strument was acknowledged before me this / 5 day of-TE)0 UGi (Y 2 r 0yvy2s ,whoi� i" me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: APPROVED BY 1 Plans Examiner is e LROrt/ 4V-C.__ IIIiii iy i CYNTHIA MICHELLE LAGANIERE MY COMMISSION # GG 16644g i ^: -�- .,,, EXPIRES: December 17, 2021 AOF P` ,, Bonded Thru Notary Public Under wrfters *********** Zoning (Revised02/24/2014) Structural Review Clerk 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2017 THROUGH SEPTEMBER 30, 2018 DBA: THOMPSONS ROOFING Business Name: Receipt #:RooFia73saseT rsrar. co Business Type: (ROOFING CONTRACTOR) Owner Name: JOHN P THOMPSON/QUAL Business Opened:07/ 10/2007 Business Location: 7021 PARK ST StateiCountylCert/Reg•CCC1328166 HOLLYWOOD Exemption Code: Business Phone: Rooms Seats Employees 1 Machines Professionals For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 2.70 0.00 0.00 29.70 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is Levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County andlor Municipality planning and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. WHEN VALIDATED Mailing Address: JOHN P THOMPSON/QUAL 7021 PARK ST HOLLYWOOD, FL 33024 2017 - 2018 Receipt 830A-17-00000066 Paid 10/03/2017 29.70 ACO OR DATE(MMJDDrYYYY) CERTIFICATE OF LIABILI THIS CERTFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Building Trades Association 6353 W. Rogers Circle, Unit 3 Boca Raton, FL 33487 License#:Edward Fowler CONTACT NHMN' Ed Fowler (Ng, Eat)800-776-5186 I ia,No1:(561) 241-0621 M6sed@buildingtrades.com INSURER(S) AFFORDING COVERAGE NAICN INSURER A Arch Specialty Insurance Co . p y 21199 INSURED J & T Quality Investments Group Inc D/B/A Thompsons Roofing, DBA PMS Roofing 7021 Park St Hollywood, FL 33024 954-297-9783 rnveon nee ,.,-.-•-•-•- .._- --- ____ INSURER B: INSURER C- INSURER D: NSURERS: INSURER E : _ _. _ - --' -' - .. '-- nC V r.IUP1 mitotic N: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE AOOL arse SUER MD POLICY NUMBER (MPM/DDmYY) (MFF MIDO�) LIMITS A X COMMERCIAL GENERAL LIABILITY AGL0015456-03 7/16/17 7/16/18 EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE I X I OCCUR DAMAGE I PREMISE SO(Eatoccurrrrence) $ 100, 000 MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GEN'L X AGGREGATE LIMIT APPLIES PER: POLICY I I PRo JECT- 1 I LOC OTHER' GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OP AGG $ 1,000,000 $ AUTOMOBILE - - -AUTOS LIABILITY ANYAUTO ALL OWNED AUTOS HIRED AUTOS _AUTOS SCHEDULED NON -OWNED COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ UMBRELLA LIAR EXCESS LIAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED I I RETENT ON$ $ WORKERS COMPENSATION AND EMPLOYERS LIABILITY Y,N ANY P0OP0IETO0PARTNEMEXECUTIVE OFFICER�MEMRER EXCLUDED? I (u.newwy 1e If yes, describe under DESCRIPTION OF OPERATIONS below N/A PER W. STATUTE I I ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEES E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS/ VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space is required) Roofing CANCELLATION Miami Shores Village Building Dept 10050 NW 2 Avenue Miami Shores, FL 33138 ACORD25(2014101) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ia.<4457-- iJ• ©1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD JEFF ATWATER CHIEF FINANICAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION ° ' CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMP CONSTRUCTION INDUSTRY EXEMPTION COMPENSATION LAW • . This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation EFFECTIVE DATE: 7/18/2017 p satton law: EXPIRATION DATE: 7117/2019 PERSON: THOMPSON JOHN FEIN: 721585910 BUSINESS NAME AND ADDRESS: J & T QUALITY INVESTMENTS GROUP INC THOMPSON'S ROOFING 7021 PARK ST HOLLYWOOD FL 33024 SCOPE OF BUSINESS OR TRADE: Licensed Roofing Contractor IMPORTANT: Pursuant to Chapter 440.05(14). F.S_ an officer of a c this section may not tEtoa>?r benefits orchapter. �o elects exemption from this chapter by t�Cug a certificate of election un only within the scope of the business or trade compensation the notice of electionbe exemra to pt: Purrsuan to h Ft r 0.05(13). ...Notice to of exempt__ as: exemptPerson a� on tote f �ncer to�i bete exempt fias � to revocationMat this sarutter the dung of the notice �t a Issuance n�� be certificate at any time for falure of the person named on the cettineate to meet section.The deparonterttssuance of a cenificate. 1 revoke a DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 QUESTIONS? (850)413--' Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner — Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Signature: ..Pn lam, /'% ors Owner State of Florida County of Miami -Dade The foregoing was acknowledge before me this By -t fi a /'r/r1 ti 4c 1 / /5day of (��y ,20 (L who is personally known to me or has produced as identification. SEAL: _ ., Date: 1/15/18 State of FLORIDA County of Broward GAF ..urn MA 7021 Park Street C""'""""" Hollywood -Florida -33024 Office-954-967-1918 Fax-954-981-1907 State Licensed Rooting Contractor LIC #CCC1328166 WWW.TMOMreta Nl3ROOP S NQ.COM FLORIDA HOME CertMood Before me this day personally appeared John Thompson who, being duly sworn, deposes and says. That he or she will be the only person working on this project located at: 10618 N.E. 11th Ave. Miami Shores. FL ,Contr-'ctor Signature Sworn (or affirmed) and subscribed before me this a day of.lM /iiZO M- By ��%n�m�v� Personally know OR Produced Identification Type of Identification Produced i:L CYNTHIA MICHELLE LAGANIERE • . MY COMMISSION # GG 166449 #5 EXPIRES: December 17, 2021 Cunded Thru Notary Public Underwriters Print, Type or Stamp Name of Mildly Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-312181 Permit Number: RF-1-18-107 Scheduled Inspection Date: September 20, 2018 Inspector: Naranjo, Ismael Owner: BENJAMIN JOHN & KRISTINA ROGERS, QCAI IAIIAIAI 'FILM4. WCICTIAIA CA!_CCC Job Address: 10618 NE 11 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: THOMPSON'S ROOFING / JSIT INVESTMENTS GROUP INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number Parcel Number 1122320280630 Phone: (954)967-1918 Building Department Comments TILE RE -ROOF Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP-311958. CREATED AS REINSPECTION FOR INSP-295459. 9/5/2018 1-MUST HAVE OPEN VALLEYS OR SEAL OPEN JOINT IN VALLEYS 2- SEAL OPEN CORNERS OF METAL FLASHINGS 9/12/2018 permit packaged soaked September 19, 2018 For Inspections please call: (305)762-4949 Page 23 of 38 Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # 1LF ` se /07 DATE: q • / ©� / �s INSPECTION AFFIDAVIT Actnn 1-)c.019.501 licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) License #: Cc-G 32 S c4.0 On or about ''1 1 0 I 9). FS 468 Building Inspector , I did personally inspect the roof deck nailing r n/ (Date & time) work at 101O I �v( 1 I A-V-e Inc) (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of JO Notary Public, Sate of Florida at Large Notary Public State of Florida Badhi Cabral f My Commission GG 202026 Expires 04/01/2022 `General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of e h plane of t permit # and address # dearly shown narked on the deck for each inspection roof with P ouicnrl nn twino NA\6 M1PN1/1r due to the charges to be incurred, they are declining. Per Florida Building Code 708.8.1 #2 The cost of the labor and material to be used exceeds the 15% rule RE: Hurricane Mitigation 10618 NE 11 Avenue Miami Shores, FL 33138 MY - " FLORIDA HOME ,•,ftr,rtf GAF MAT! RtAIn 7021 Park Street COHPOHATtOY lollywoocf Florida -33024 ()1rice-954-967-1918 F x-954-981-1907 State Licensed Rool,ing Contractor LIC #CCC1328166 WVW' W.TMOMPlON1111 cso lNa.QOM •. • • .... . . • • . . . . . . . . . • • • • • • . • . •• •• • • . .. .•• . . • •• • • • . . In regard to the roof to wall connections, the homeowner is regiieStfig that . • . • . • The cost of reroofing is at $26,500 with 9 corners with a minimum cost per corner for labor and material at 450.00 that exceeds the 15% cost of the contract. 9x450 = $4,050.00 15% of contract = $3,975.00 John Thompson President Thompson's Roofing it- ) i 6 2018 Q II BY GITY C PY r 0 >- m ZONING DEPT UFFICE IF T Summary Report Property Information Folio: 11-2232-028-0630 Property Address: Owner 10618 NE 11 AVE Miami Shores, FL 33138-2121 BENJAMIN JOHN ROGERS KRISTINA ROGERS Mailing Address 10618 NE 11 AVE MIAMI, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds l Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 3,011 Sq.Ft Lot Size 9,750 Sq.Ft Year Built 1951 Assessment Information Year 2017 2016 2015 Land Value •,0.5 $177,606 $141,174 Building Value $200,257 $200,989 $201,721 XF Value • ,233 $32,693 $21,544 Market Value $471,575 $411,288 $364,439 Assessed Value $347,726 $340,574 $338,207 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $123,849 $70,714 $26,232 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES ESTATES PB 47-58 LOT 13 BLK 4 LOT SIZE 75.000 X 130 OR 20185-0785 01 2002 1 Generated On : 12/22/2017 Taxable Value Information 2017 2016 2015 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $297,726 $290,574 $288,207 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $322,726 $315,574 $313,207 City Exemption Value $50,000 $50,000 .............. $50,000 Taxable Value $297,726 $290,574 $288,207 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $297,726 $290,574 $288,207 Sales Information Previous Sale Price OR Book - Pa 9a Qualification Description 12/16/2011 $450,000 27946-3867 Qual by exam of deed 03/16/2011 $255,000 27664-3326 Financial inst or "In Lieu of Forclosure" stated 01/20/2011 $415,144 27605-4632 Financial inst or "In Lieu of Forciosure" stated 01/01/2002 $226,000 20185-0785 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.govfinfoldisclaimer.asp Version: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE .... • • COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFINQep r IT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NO LOW Roof System Required Sections of the Permit Application Form Attachments'Rbtiterbd See List tiQICM • Low Slope Application A,B,C 1,2,3,4,5441. • • .... Prescriptive BUR-RAS 150 A,B,C 4,5,6,7. •.. • 1 Asphaltic Shingles A,B,D 1,2,4,5$ P: •: Concrete or Clay Tile A,B,D,E 1,2,3,446,7 . • • Metal Roofs A,B,D 1,2,3,4,5,8,9 • Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation . • • • . • . � . .. . • • • • • . • 15.36 INTERNATIONAL CODE COUNCIL FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliczcr Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractors Name 1716 rne Sn (11, 16lJ 1 L Job Address f 60 /k 11 X/111/ ROOF CATEGORY ❑ Low Slope 0 Mechanically Fastened Tile ❑ Asphaltic Shingles 0 Metal Panel/Shingles x ❑ Prescriptive BUR-RAS 150 • • • • • . . ROOF TYPE •...{. . • • O New roof 0 Repair 0 Maintenance Reroofing • • • ▪ • p Recorerir% • .•.. 1'. • r,nt .. • 1 ROOF SYSTEM INFORMATI 1 1 1 1 1 1 .... i . . • •• •-*. ....I. • .• . . •. • . . 1 • • •. • . Mortar/alesive Set 'files .... Wood £&ingies/Shakes. • • Low Slope Roof Area (SF) -es' Steep Sloped Roof AREA (SSF) '1 Total (SF) _S) � i ; I 1 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- 1 sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 18 ! 22 24 / c't '1 25 m �� Ot <111 a �a t\ 6E 40 IIIIIIIII 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INIERNATIONAb CODE.000NCI19 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: 3q1.) P1: (pg., P1: /CO, • ••'• Deck Type: Rooi Slope: : 12 Ridge Ventilation? •• • 1 1 1 1 1 1 .6090. • • • 1• • • •1•••• •1•.•• •ee • J. • • ailoo • •••. • • • • 0000 • . • .• Type Underlayment: Insulation: Fire Barrier: Mean Roof Height: Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: Roof Covering: Type & Size Drip Edge: • • • •-0 • • •• • • • •• • • fats-k-cic-co Plus 1 '• •1•••• • • •1•••• FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL! Florida Building Code 5th Edition (2014) High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based file systems, choose either Method 1 or 2. Compared the values for M, with the values from M r. If the M r valves are greater than or equal to the Mr values, for each area of the roof:, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (111z_ , I — Mg: (y� D) _t (f, NOA 11� D rig. • • (P(n2: z ?, + 3 = del l l ) — Mg: (p .O I NOA (o'; • — •.... • x?. ,31 =31 al )—Mg:(a,vl NOA11 .4d3:Z • Method 2 "Simplified Tile Calculation Per Table Below; Required Moment of Resistance (Mr) From Table Below NOA 1Vlt 0000 • • Mr Required Moment Resistance* • •' • •' ' • • .. ; Mean Roof Height 15' 20' 25' . . • 30' • • • 40'• — Roof Slope 2: 2 34A 36.5 38.2 ; 3(17 • • 42.2 3:12 32.2 34.4 36.0 '37.4 • . • 3%.e, 4:12 30.4 32.2 33.8 35.1 - 57.S 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26A 28.0 29A 30.5 32A 7:12 24A 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Pt: zl: = z w:= )-W: zcos 9: = F,1: NOA F' (P2 : z l: = z w: _ ) — W: z cos 9: = Fr2: NOA F' (P3 : z l: = z w: _ ) — W: z cos 9: = F,s: NOA F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope g Job Site Aerodynamic Multiplier 7L NOA Restoring Moment due to Gravity Ms NOA Attachment Resistance Mr NOA Requhed Moment Resistance Mr Calculated Minimum Attachment Resistance F NOA Required Uplift Resistance Fr Calculated Amur Tik Weight W NOA Tile Dimensions 1= length vr= width NOA All calculations must be submitted to the Building Official at the time of permit application. 00004 •� • .. • • • • • • • • 123 01-48 8/15 PAGES • • 114 • •. • - Florida_ Building Code 5th Edition (2014) High Velocity Hurricane Zone Uniform Permit Application Form • • • • . •••• • . .... • . • • .. • . • • • Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Number: . ,e. iA(I(nimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): ' P1: P2: P3: • .... . Maximwnediesign Pressure ' (From the'NOA Specific System): M thod pf the attachment: Roof Slope: :12 Steep Sloped Roof System Description Deck Type: ype Underlayment: nsulation: Fire Barrier. astener Type & Spacing: Ridge Ventilation? dhesive Type: ype Cap Sheet: - oof Covering: Typi& Size Drip dge: Mean Roof Height: - 123 01-48 8/15 PAGE 4 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the WittA/ with the required roofing permit, and to explain to the owner the content of the section. The erovis+ons of 8aotio�•R4402. govern the minimum requirements and standards of the industry for roofing system instaflatiorrs. AddZtiadye the •• following items should be addressed as part of the agreement between the owner ant Me flQrtttactor.'rhe owner's • initial in the designated space indicates that the item has been explained. • ••... • • • •... 2. Renailing wood decks: When replacing roofing, the existing wcwd'W deck flZay'hdve to be renailed in accordance with the current provisions of Section R4403. (The o4 uk is usually •• ro concealed prior to removing the existing roof system). • • • • • • • • •• •• • • •• • • •• • 4. AZExposed Ceiling: Exposed, open beam ceilings are where the underside of the roordecking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. r Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is noverloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this ischarge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in acc ance with the requirements of Sections R4402, R4403 and 3 ner/Ag is Sig ature Date /obi L 11 14✓-- Property Address Revised on 7/9/2009 LD;07/01/2015; ontractor Si• at. - Date Permit Number 1 MIAMI-DAD—El-ED COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy . .. .. . • • .... • • • • • • This NOA is being issued under the applicable rules and regulations governing the use of canstitiafion materials. Th4 documentation submitted has been reviewed and accepted by Miami -Dade County RER-Prodeet.Controd S e ;on to ;e used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdictith•(AHJ)' .... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Deduct Conn+o' Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tgtt to have this product or material tested for quality assurance purposes. If this product or material fails to tierfoTfn in tlX zcdepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediat;l4re poke, modify, or • • . • suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke tlti$"eptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Low Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0314.06 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino MIAMI.DADE COUNTY APPROVED NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do ubr'hkieed the design pressure values obtained by calculations in compliance with RAS 127: u.ing:the values: listed in section 4 herein. The attachment calculations shall be done as a moment based sy%tm,. . • 2. PRODUCT DESCRIPTION: Manufactured by Applicant Low Profile Concrete Tile Low Profile Concrete Tile Low Profile Concrete Tile Low Profile Concrete Tile Low Profile Concrete Tile Trim Pieces MIAMI-DADE COUNTY APPROVED Dimensions Lenght = 17" Width = 12'/." Thickness = '/2" Lenght = 17" Width 121/4' Thickness ='/2" Lenght = 17" Width = 12 1/4' Thickness = '/2" Lenght = 17" Width = 12 '/<" Thickness ='h" Lenght = 17" Width = 12'/4" Thickness ='/2" Lenght = varies Width = varies varying thickness Test Specifications TAS 112 Type 3a Class 1II TAS 112 Type 3a Class III TAS 112 Type 3a Class III TAS 112 Type 3a Class III TAS 112 Type 3a Class III TAS 112 .... . . Knockoff Description . .... . . . • . . • . Flat profile concrete took* equipped with tvyq.„. nail holes. For adhesive set, direrdc'ditor . . battened nail -on applioatloi s. .. •. • .• • Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile with slate finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile with shake finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile brushed finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Accessory trim, concrete roof pieces for use at hips, rakes and ridges. Manufactured for each tile profile. NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 2 of 9 2.1 EVIDENCE SUBMITTED: Test Agency PRI Asphalt Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. ATL of South Florida ATL of South Florida MIAMIDADE COUNTY APPROVED Test Identifier ERPF-001-02-01 7161-03 Appendix III 7161-03 Appendix III 7161-03 Appendix II P0402 Letter Dated Aug. 1, Test Name/Report TAS 112 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) • • • • • Withdrawal Resistance Testing of screw vs. smooth shank nails • Wind Tunnel Testing • • • • • . 1994 TAS 108 (Nail -On) ' P09647-01 94-084 25-7094-(2, 5, & 8) 25-7183-(5 thru 6) 25-7214-(1, 5 , & 8) 25-7487-2 25-7496-(1 & 4) 25-7804-6 520109-1 520111-4 520191-1 Calculations Calculations RT1214.01-15 RT0706.01-17 Wind Tunnel Testing • • • •' TAS 108 (Mortar Set) : • Static Uplift Testing . • TAS 101 (Mortar Set)' • •' Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier Restoring Moments Due to Gravity TAS-112 TAS-112 Date Aug. 2006 Dec. 1991 Dec. 1991 • Aec. 1991 • • • Seri. 1993 • • � • • .AU. 1994 •••• • iie u . 1994 • �Via •q 1994 •• • • • •• • "Oct. 1994 • • • • •• Feb. 1995 March, 1995 Dec. 1995 Dec. 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 Sep. 2006 12/17/15 09/25/17 NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 3 of 9 • 3 LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be required, refer to applicable Building Code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless' Mated otherwise by the underlayment material manufacturers published literature. • • • • 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall bg irl QQ�npliar +vttt► • • • applicable Building Code. • 3.7 All products listed herein shall have a quality assurance audit in accordance with theJ'lblh"da BuilriugCode • Rule 61 G20-3 of the Florida Administrative Code. • • • • • 4 INSTALLATION: • • • ••• •• •• • • • • • • • • • • � • 4.1 Eagle Roofing Products LLC Low Profile Flat Concrete Roof Tiles and its components shall be iri$t3118Q in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. • • • • 4.2 Data For Attachment Calculations • •• • • • • . • •• • Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Low Profile Flat Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) A (ft3) Batten Application Direct Deck Application Low Profile Flat Tile 0.301 0.278 Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Low Profile Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens 2-10d Ring Shank Nails 30.9 38.1 17.2 MIAMIDADE COUNTY APPROVED NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 4 of 9 Low Profile Flat Tile Low Profile Flat Tile 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 •�•,34.8 •,,,,• ,,,, 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 ' • •' : • 32.2 - • • • • 2-10d Ring Shank Nails' 50.3 65.5 •........ :•••:15.3 ••••• 1. Installation with a 4" tile headlap and fasteners are located a min. of 2'/2" from Jcipf tile..... ,,;, . . •• .. • . • . • • •• • • • • • • •• Table 5: Attachment Resistance Expressed as a Moment MZ(ft-Ip) "•' • • for Two Patty Adhesive Set Systems• •••• Tile Profile Tile Application AttachmentResistance Low Profile Flat Tile Adhesive' 31.32 1 See manufactures component approval for installation requirements. 2 The Dow Chemical Company TileBond Average weight per patty 13.9 grams. ICP Adhesives Polyset® AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Low Profile Flat Tile ICP Adhesives Polyset® AH-160 118.93 ICP Adhesives Polyset® AH-160 40.44 3 Large paddy placement of 45 grams of PolyProTM. 4 Medium paddy placement of 24 grams of PolyProT"'. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Low Profile Flat Tile Mortar Set5 43.9 5 Tile-Tite Roof Tile Mortar. NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 5 of 9 • • 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". EA-G-07" FLORIDA (LOCATED ON UNDERSIDE OF TILE) OR EAGLE FL (LOCATED ON FRONTSIDE OF TILE) .... . .. .. .... .. . ... . • . . • . • .• . .. ... .. • .. • • . . . • LOW PROFILE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. MIAMFDADE COUNTY APPROVED NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 6 of 9 PROFILE DRAWING LOW PROFILE ROOF TILE LOW PROFILE ROOF TILE MIAMIDADE COUNTY APPROVED ... . . .... ••• • • • • • •••• • • . ••• • • • .. .. •••• • • • . • • • •• • . . • • • • • • • • • • • .. . .. • • • • . . NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 7 of 9 LOW PROFILE ROOF TILE LOW PROFILE ROOF TILE MIAMIDADE COUNTY APPROVED .•.. . • •••. . • • . .. .• . .... . • .• •. • • • • • • • • • • •• • • • • • • • •• • •• • • • • • • •• • • . • . • • • • NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 8 of 9 LOW PROFILE ROOF TILE END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED .... . • .... . . .. •. . • • • • • ••• •• • •.. • • • • • • • • • • • • • • • •••• • • • .. • • • • •• • • • •• • • • • • NOA No. 17-0822.13 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 9 of 9 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). . This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count Prpd}Ict CoritMl•Sectiod (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tlf right to havetiis product or material tested for quality assurance purposes. If this product or material fails to irform in the accepted • manner, the manufacturer will incur the expense of such testing and the AHJ may immediate• evoke, rgodify, or . . suspend the use of such product or material within their jurisdiction. RER reserves the right IA =Voke tin acceptance?: • • if it is determined by Miami -Dade County Product Control Section that this product or material Oils to meat•thr requirements of the applicable building code. • • • • • • • This product is approved as described herein, and has been designed to comply with the F1oQt193 ilding Cote including the High Velocity Hurricane Zone of the Florida Building Code. • .• DESCRIPTION: Polyglass Polystick Underlayments • • • . .• • . •. . • . . •• • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • .• . • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. MIAMFDADE COUNTY APPROVED NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick IR-Xe Manufacturing Location #1 & #2 Polystick Dual Pro Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick TU Max Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 MIAMFDADE COUNTY APPROVED Dimensions 65' x 3'33/8" Or65'x3' 60 mils thick 61' x 3'33/8" 60 mils thick 61' x 3'3 3/8" 60 mils thick 65'8" x 3'3-3/8" 60 mils thick 32'10" x 3'3 3/8" 130 mils thick 65' x 3'33/8" 80 mils thick 65'8" x 3'33/8" 60 mils thick 65'8" x 3'33/8" 60 mils thick 32'10"x3'33/x" Test Specification ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 TAS 103 TAS 103 and ASTM D 6164 Product Description A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. A rubberized asphalt self -adhering, glassftl3dtfpolyester reinforced waterproofing metibrailm. Designed as a metal roofing and roof tile unctehayment. • A rubberized asphalt self-adllbtMg• ,'glass-fiber/polyesi r • • • reinforced waterproofing mem'rana. Desigied's a metal.. • roofing and roof the underlayjrmt4 • • • A rubberized asphalt self-adhn in polyester reinforced waterproofing membrane. Dapper! as a 4 rooi;tile underlat • • • meny. • . . A rubberized asphalt waterproofing memblue,•glass- • . • . . • • . fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self -adhering, glass-fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polyester reinforced, SBS modified bitumen membrane with a sanded back face and a granule top surface. For use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 • MANUFACTURING PLANTS: 1. Haze1ton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Agency Test Identifier Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. P10870.09.08-R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX 14E8A DX23D8B DX23D8A Test Name/Report TAS 103 TAS 103/ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G155 TAS 110/ASTM D4798 & D1970 ASTM D 1623 ASTM D6164 • TAS 103, TAS 110 & ASTK4 4j 1623 ASTM D1623 • TAS 103 & TAS 111i" . . ASTM D 1970 & TAS•c16.0.... • TAS 103 & TAS 110 ASTM D1970 & TAS I11)••• TAS 103 ; • TAS 103 • • TAS 103/ASTM D4798 & €455� TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 Date 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 •.ag/07/12 •••W /02/13 ..Q3/12/14 10/03/14 10107/14 • • 1 f'17/14 • Q6127/16 • 06/27/16 • • • • • • • • 09429/06 • 11N10/07 • . • ey'gb/09 •• • 04/01/08 11/09/09 02/18/10 02/18/10 • • • LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMIDADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMIDADE COUNTY APPROVED NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 • • INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at q,minimum 4v •: ad•1ap. (for base sheet only) • . .• .. . . • Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polysticg 1'U Ma'x, Polystick • TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus if--adh ered7 . • : e • Surfacing: See General Limitations Below. • • • • • . . • . . ..• .. ..• . . Deck Type 1: Wood, non -insulated : . :• Deck Description: Min. 19/32" plywood or wood plank . System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered " ' ' • Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. MIAMI DADE COUNTY APPROVED NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and cj41,aps shall be a minimum of 6". Roll the membrane into place after removing the release strip..Vertical strfppingof the. roof with Polystick is acceptable. Membrane shall be back nailed in accordance witfiepplrcable building code. • • • 4. When applying the membrane in the valley, start at the low point and work to the hi Point, rolling the ... . membrane from the center outward in both directions. • • • • • • 5. For ridge applications, center the membrane and roll from the center outward in both directions. . 6. Roll or broom the entire membrane surface so as to have full contact with the surfacE,• grAbg specidl f ttentiori • • • • to lap areas. . 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly cusrent Product Contxol..:. Notice of Acceptance. • • • • • . 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The ?lashing tap 'aliall be • pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystia shall be applied over the underlayment. • GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 MIAMI-DADE COUNTY APPROVED • 9. When loading roof tiles on rooftile underlayment for (direct -to -deck) tile assemblies' the Trlaximum Woof slopt; shall be as follows: (See Table Below) • •••• Rule 61 G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex 56 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. • '••• • Polystick TU P may be used in mechanically fastened rooftile applications with the:eatkion otmorfar set tile applications. • • •• • • • • • • • Tile Profile Polystick MTS Elastoflex S6 G Polystick TU Plus, TU P, Tile Pro, Dual Pro Polystick TU Max Polysfier : MTS,kis•• • : • : Siy'stadi.(E3) .• MTTPIus wit `" •TU pus • • Flat Tile Prohibited without battens 4:12 6:12 6:12 512 .•. • ' 6:12 • " • :., • Profiled Tile Prohibited without battens 4:12 6:12 6:12 4:12 ••' •• �6:12 The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. r POL`ST1CKTU Plus MIAMI.DADE COUNTY APPROVED 6 (6 Max. Per Stack) 12 NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 • • •• • • • •• • • • • • • 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. • • • • If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU l;,.lj'stick. TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a reques! may ti jacle to the • Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control SeettQlft f8r approval provided • • • • that appropriate documentation is provided to detail compatibility of the products, wmduprft resistai3ce, and tre•..: • testing results. • • • POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTIek NIEMBRNN S • � • •• PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPiCIFjC APPiPCAT oNS.• LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECO111NbATIOIai;. • • • •. • 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 61/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. MIAMI DADE COUNTY APPROVED NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 . • 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. • • • • • • 13. Questions in regards to the application of Polyglass products should be directed to our Technical SUvipes .• Department at 1 (800) 894-4563. • • 14. Polyglass recommends that applicators follow good roofing practices and applicable pr.00ed Tres as.outlined by • • the National Roofing Contractors Association (NRCA). • • • • • . . .• •• .... . . . •• • PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIE G APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMEND'ATIOI S, • ; • • • • •• END OF THIS ACCEPTANCE MIAM WADE COUNTY APPROVED .•• . • • • NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAMI couffy DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL. 33065 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.sov/economv • ... • • .. .. . • • • • This NOA is being issued under the applicable rules and regulations governing the use of Cdtisthtction materials. T)aa...: documentation submitted has been reviewed and accepted by Miami -Dade County RER-Praduct•Contro2 & ion to fie • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction •(%HJ). • • • • •• • This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count)? P'Pbduct Colarol•Section • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the ngfitito hale this product • • or material tested for quality assurance purposes. If this product or material fails to perform ill th ,accepted mariner, the • manufacturer will incur the expense of such testing and the AHJ may immediately revoke, Ajgtiifj:, or susirend the uMb • • •: of such product or material within their jurisdiction. RER reserves the right to revoke this accepiare4•if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. • • • DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. MIAMI DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as d .termined by•Appj 'able building code, do not exceed the design pressure values obtained by calculations in compliant *iltr Roofing . Application Standard RAS 127. For use with approved flat, low, and high profile roof tile syste mis.using itlf • • Adhesives Polyset® AH-160. • • • • PRODUCTS MANUFACTURED BY APPLICANT: Product ICP Adhesives Polyset®AH-160 ICP Adhesives Foam Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 Dimensions N/A N/A Test Specifications TAS 101 .... • . • .... . .... • Product Description • • •• . • • •. • • . • • .• Two component polyurethane fdAilf aelhesiue Dispensing Equipment Dispensing Equipment .. . . . • ..• . . PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Ce11 Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMI•DADE COUNTY APPROVED NOA No.: 17-0322:03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 • • EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11./02195 25-7492 SSTD 11-93 • f1/42 45 . . . • ..• . • . Miles Laboratories NB-589-631 ASTM D 1623 Y2/01/94 . • • Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services .•.. • • • . • • • • • • 9637-92 ASTM E 108 0413Q493 • • . • . . . 01-6743-011 ASTM E 108 • • • • 11 /16/94 • 01-6739-062b[1] ASTM E 84 • • • 0:1'15 • ¢1 • • • 7050.02.96-1 TAS 114 • • • • • 037i4 % . P36700.04.12 ASTM D 1623 04/Tel 2 P39740.02.12 TAS 101 02/21/12 TAS 123 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. MIAM DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 1CP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. Thaadhesive • • attachment data is noted in the roof tile assembly NOA. • • • • • • • 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with RoofinaArp1' ratio% • • • Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction andAlArltpnance Bgoklet. . . 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed tirIC.P AdltWAs and • Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatd6'tb the authority having • • • jurisdiction. • • • • •• •• • • ••• •• •• • 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application •, of any adhesive. The mix ratio between the "A" component and the "B" component shall be•maintggej between • • • • 1.0-1.15 (A): 1.0 (B). •• •• . ••• • •• • • • 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or.IC1; • Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. MIAMI•DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 s inches • 1 4 • Low Profile #2 • 12-14 sq. .. . inches . 34. High Profile #2 .•..•. 17-19 sq. inches •... • •••- •. 30 • ..•. Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at • head of tile 9-11 sq. inches at.. overlap .. • •'12 graits•pe paddy•... • . .••. ••.. ... • • • • .. •. • •••. Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal: edge) 20-25 sq. inches each .. bead • .. • 17 grams per bead...1 •. • •• " " .. • • • . • Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches ..• . 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. MILMIIa ADE COUNTY BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 • . •. •• • •• • .• • •• •• MIAMI.DADE COUNTY APPROVED •• •• • • • • • Medium Profile / Double ran. •• • 1. ADHESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. •. • • • • •••• 2. Continue in same manners ins t ure apppra gxely 17 • • (109.7 cm2) — 23 (148.4 erre) square' inch adhesi0d •' •' contact with the underside bf the tile. ' •••• • • • • • • • • • • • • • • • • • •• • • • • •• • • • • Starting at the eave course, apply a muiin-Tum 2" • • • • • •• • • (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 • ADHESIVE PLACEMENT DETAIL # 2 Battens optional fay* Course .` ., a �- �- +- Hail through plastic cement (when requi►edl Und.rlaym.M 2 in. Battens optional 1 Eave Course Paddy 4Beneath Tile) 2 Lave Clown - MIAMFDADE COUNTY APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately. f 7 i109.7 cm2) — 23 (148.4 cm2) square firth adhesive cbniact with tne.: • underside of the tile. • • • • 2. At the second course, apply.,14inimuni 2' (.50.8mr$j • • • x 7" (177.8 mm) x 1" (25.M erialia)•foam Fauay onto tl're• • • underlayment positioned as•eirvnn undvrt1 e. • strengthening rib closest to the bverlocketff tht tile being set. • • • • • • • • • • • 3. Continue in same manner.4n§etrl:approxa ely 10': (64.5 cm2) - 12 (77.4 cm2) square inch ddhdsite contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 MIAMFDADE COUNTY APPROVED ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. .... 2. At the second course, apply a minimum 2: (SD.8mm} . • • . •• x 7" (177.8 mm) x 1" (25.4 tnm)foam Pvkd1 onto the • • underlayment positioned aS%NMI under the pan portion of the tile closest tOoverlock ofthe tile • .... being set. • •.•. •• 3. Continue in same manner.d&Svr apprdggtately 17" (109.7 cm2) - 19 (122.6 cn124 sre inch adhesive • • contact with the underside of theotile. • • • • • • • • •• • •• • • • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8of11 • ADHESIVE PLACEMENT DETAIL # 3 Nail through plastic cement Paddy (between tiles) (when required) Battens optional x0(n. Single pad under 61 Single paddy 00 undedayment Paddy (under tile) Fascia Save Closure Flat/Low Profile Tile Nail through plastic cement (when required) on top ofdteee Eave Course MIAMI-DADE COUNTY APPROVED Single paddy under toe Medium Profile Tile Paddy (between tiles) Paddy (under tile) Eave Closure Fascia 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with tie underside o j'j h. tile • • • • •• • • • • • • 2. Apply a 4" (101.6 mm).e4:(401.6 mm4 x 1" (2S.4 • mm) foam paddy onto t x 4erlayljlatiyst belew • the second course line pdsrifibned fo9in paddy • under the strengthening nb•%p flat the"or under tile •• pan portion of the tile, Sclomt.to the underlock for • • the second course tile tQ be'irl$tallecc, Inwre • approximately 8-9 in2 (51.6-58.1 criS2rdI'tdhesiNie • contact with the underside ofthe tile.. • • • • • • • •• • (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plastic • Single paddy under the twhen required) Battens optional singledy �� 4xain. single 2 x 4 in. paddy on top of Ole 10 in: Paddy (between tiles) Paddy (under tile) Fasda Weephole Eave dosure Drip edge High Profile Tile MIAMI•DADE COUNTY APPROVED 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside•(?P'tttttile at the head of the tile. Co>!ltinve in same $canner. •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• •• • • • • • • • • • • • • •• • • • • • • • • •• • •• • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. in contact with the pan tile. 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. Underlayment Eave closure (motar shown) Weephole Fascia Board Steep pitch applications (when required) Sheathing Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile MIAMI.DADE COUNTY APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same mariner pringingI r.o pan courses up toward th8 444 Insure . approximately 65 (41•94:ona2) — 7D•( Y1'6 cm2,) square inch adhesivesaixrtaot with theunderside • of the pan tile. •• • • • • • •••• • • • • • • 3. Turn covers upside down exposing t%e underside• • • of the tile. Apply a nppirpp;n 1" (2n. mm) x (254 mm) bead of adtesl'' directjy on.the inr�Y,,;• edge of each side of the cover tile; Ve'a , approximately 3/4" (1944) to 1' (25, mm) • • from the outside edge of the tile, irnwar d, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 •