Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-18-2116
Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Issue Date: 8/992018 Permit NO. RF- -1.8- 116 Permit Type: Roof Work Classification: Tile/Flat Permit Status: APPROVED Expiration: 02/05/2019 Parcel Number Applicant 269 NE 100 Street Miami Shores, FL 33138- 1132060134690 Block: Lot: CHRISTINE WELSTEAD Owner Information Address Phone Cell CHRISTINE WELSTEAD 269 NE 100 Street MIAMI SHORES FL 33138- (305)332-6739 Contractor(s) A&J ROOFING CORP Phone Cell Phone (305)599-2782 (305)804-1342 Valuation: Total Sq Feet: $ 900.00 150 Type of Work: Repair Additional Info: REPAIR APPROX. 25 FIELD TILE, ALSO Classification: Residential Scanning: 5 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $0.00 $0.00 $0.00 $0.00 $250.00 $0.00 $0.00 $250.00 Pay Date Pay Type Invoice # RF-8-18-68486 08/09/2018 Check #: 5376 Amt Paid Amt Due $ 250.00 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Review Roof Roof in Progress Renailing Affidavit Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoningi.`U -, I authorize the above -named contractor to do the work stated. Autho e• ign ure: Owner r pplicant / Contractor / Agent August 09, 2018 Date Bui • ing Department Copy August 09, 2018 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number: INSP-000283-2018 Permit Number: RF-8-18-2116 Scheduled Inspection Date: October 01, 2018 Inspector: Naranjo, Ismael Owner: CHRISTINE WELSTEAD Address: 269 NE 100 ST Miami Shores, FL 33138 Project: <NONE) Contractor: A&J ROOFING CORP MIGUEL GUERRERO Permit Type: Roof Inspection Type: Roofing Final Work Classification: Tile/Fiat Phone Number: 3053326739 Parcel Number: 1132060134690 Phone Number: 3055992782 Building Department Comments REPAIR APPROX. 25 FIELD TILE, ALSO FLAT ROOF REPLACED RF-12-15-3018 Checklist Item General Comments Passed Passed False Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection tee is paid. Comments Inspector Comments October 01, 2018 For Inspections please call: 305-782.4949 Page 17 of 24 BUILDING PERMIT APPLICATION BUILDING ❑ELECTRIC ❑PLUMBING ❑ MECHANICAL JOB ADDRESS: 269 NE 100 ST City: Miami Shores Folio/Parcel#: 11-3206-013-4690 Occupancy Type: resident Load: Miami Shores Village Building Department, 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 i cEi 44' 0 CFO 418 FBC 2QQ0n olio Master Permit No. 1i - J011r Sub Permit No. ❑■ ROOFING ❑ REVISION ❑ PUBLIC WORKS ❑ CHANGE OF CONTRACTOR County: ❑ EXTENSION •RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS Miami Dade Zip: Is the Building Historically Designated: Yes Construction Type: Roofing Flood Zone: NO XX BFE: FFE: OWNER: Name (Fee Simple Titleholder): Christine Welstead Phone#: Address:269 NE 100 ST City: Miami Shores State: FL Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Address: 4337 E 11 Ave A & J Roofing Corp City: Hialeah Qualifier Name: Miguel Guerrero State Certification or Registration #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: nn Value of Work for this Permit: $ vl 00 ' O'O Square/Linear Footage of Work: I 50 I Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Tile and Flat Roof Repair 3b' Lou) SIdfe, ci-O v_-ej la CA jab' s---eep S1o,pC, Specify color of color thru tile: State: Florida CCC1328038 Zip: 33138 Phone#: 305-599-2782 Zip: 33013 Phone#: Submittal Fee $ �� Permit Fee $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) Certificate of Competency #: RC 1S-;o'8 CCF $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this The for going instrument was acknowledged before e this day of a, 20 , by day of , 20 l by �,1r1s-1- 1, te LOe 1 S Gi;4who is personally known to M((' 0 /(.0 G uea-ef— who is personally known to Signature me or who has produced as me or who has produced as identification and who did take an bath. NOTARY PUBLIC: Sign` la` `' -.., Print ^ `c. medrwiclr Seal: Notary Pub is - tate o r on.. Commission # GG 76694 My Comm. Expires Feb 26, 2021 Borded through Natioral Notary Assn. identification and who did take an oath. NOTARY PUBLIC: CONTRACTOR Pti ''''' ARAISYVARA Notary Public - State of Florida Commission 4 GG 76694 My Comm. Expires Feb 26, 2021 Bord=d rhrouc'• Natigral NotaryAssr. ***************************** *****************************************i0411p1KIMattiv*** APPROVED BY 9 ,T Sign: COIKCI----1 Print: Seal: Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) CERTIFICATE OF LIABILITY INSURANCE Date I 08/08/2018 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691 (727) 938-5562 This Certificate is issued as a matter of information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer A: Lion Insurance Company 11075 Insurer B. Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL LIABILITY Commercial General Liability Each Occurrence $ Damage to rented premises (EA occurrence) g Claims Made Occur Med Exp $ General 3 Personal Adv Injury $ aggregate limit applies per: Policy ❑ Project ❑ LOC General Aggregate $ Products - Comp/Op Agg $ AUTOMOBILE LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non -Owned Autos Combined Single Limit (EA Accident) $ Bodily Injury (Per Person) $ Bodily Injury (Per Accident) $ Property Damage (Per Accident) $ EXCESS/UMBRELLA LIABILITY Occur ❑ Claims Made Deductible Each Occurrence Aggregate A Workers Employers' Any proprietor/partner/executive excluded? If Yes, describe Compensation and Liability officer/member No under special provisions below. WC 71949 01/01/2018 01/01/2019 x l WC Statu- tory Limits I 1OTH- ER E.L. Each Accident $1.000,000 E.L. Disease - Ea Employee $1,000,000 E.L. Disease - Policy Limits $1,000,000 Other Lion Insurance Company is A.M. Best Company rated A (Excellent). AMB # 12616 Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 91-67-590 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": A & ] Roofing Corp Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 08/08/2018 (TD) Begin Date 12/12/2013 CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE BUILDING DEPARTMENT 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives. - A �•f ' " " AC �® l`/----- CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 8/08/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Casualty Systems, Inc . 3331 SW 107 Ave Miami FL 33165 CONTACT Juan Hernandez NAME: (ac°. No. Ext): (305) 551-0590 FAX No): (305) 551-0857 airaess:Admire@casualtysystems.com INSURER(S) AFFORDING COVERAGE NAIC # INSURER A :Burlington Insurance Company INSURED A & J Roofing Corp. 4337 E 11 Ave Hialeah FL 33010 INSURER B : INSURER C : INSURERD: INSURER E : INSURERF: :CL1761905074 REVISION NUMBER: v THIS 'IS TO CERTIFY THAT THE POLICIES'OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR .. TYPE OF INSURANCE ADDL INSD SUBR WVD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY 28913W39839 5/15/2018 5/15/2019 EACH OCCURRENCE $ 1, 000, 000 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 100, 000 CLAIMS -MADE X OCCUR MED EXP (Any one person) $ 1,000 PERSONAL & ADV INJURY $ 1, 000, 000 GENERAL AGGREGATE $ 2,000,000 GEN'L X AGGREGATE POLICY OTHER: LIMIT APPLIES PRO JECT PER; LOC 2,000,000 AUTOMOBILE LIABILITY — SCHEDULED AUTOS NON -OWNED AUTOS (Ea acccideDISINGLE LIMIT $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident $ PIP $ UMBRELLA LIAB EXCESS LIAB O OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ $ DED RETENT ON $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under YIN N / A PER OTH- STATUTE ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) Roofing Contractor Lic # CCC1328038 CERTIFICATE HOLDER CANCELLATION Miami Shores Village Building Dept. 10050 NE 2nd Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Ethel Gruntler/BUNNY ACORD 25 (2014/01) INS025 (201401) © 1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD BUILDING PERMIT APPLICATION I BUILDING ❑ ELECTRIC PLUMBING ❑ MECHANICAL JOB ADDRESS: 269 NE 100 ST Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 aster Permit No. f f lS 3019 b, Permit No. ❑■ ROOFING ❑ PUBLIC WORKS ❑ REVISION ❑ CHANGE OF CONTRACTOR ,EXTENSION ❑ CANCELLATION ❑ RENEWAL ❑ SHOP DRAWINGS City: Miami Shores Folio/Parcel#: 11-3206-013-4690 Occupancy Type: Load: County: Miami Dade Zip: 3313� Is the Building Historically Designated: Yes NO truction Type: Roofing Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Chri/( o..rl `Istead Phone#: (S..05) 332.- 6q `3 / Address: 269 NE 100 ST City: Miami Shores State Zip: 33138 Tenant/Lessee Name: Email: Phone#: CONTRACTOR: Company Name: Address: 4337 E 11 Ave A & J Roofing Corp Phone#: 305-599-2782 City: Hialeah State: Florida Qualifier Name: Miguel Guerrero State Certification or Registration #: CCC1328038 Certificate of Competency #: Zip: 33013 Phone#: 305-599-2782 DESIGNER: Architect/Engineer: Address: �7 Value of Work for this Permit: $ 9� Type of Work: ❑ Addition ❑ Alteration Description of Work: Phone#: City: State: Zip: Square/Linear Footage of Work: /540 New ❑ Repair/Replace I —I Demolition ice-futi C11'i`ZcAy o26p4aL&Pi dQ�aB--�ai Specify color of color thru tile: TerraC01- Submittal Fee $ 6-0 Permit Fee $ 25Der' CCF $ a Scanning Fee $ 4 Radon Fee $ J.` DBPR $ 3• �"S Technology Fee $ oSO Training/Education Fee $ Structural Reviews $ 0.20 CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ 0 500 22qDID (Revised02/24/2014) 7244 .00 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ASA,12.4 Signature t4 OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this / day of ! , 20 �,�, by a day of bece-Y-A( , 20 15 , by /� ( r (iSi-k, 11%1I/e&s, who is personally known to rre w , who is p tsonally known to me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: ig . RERO • Lary Public - ate of Florida v. o• ..r • My Comm. Expires May 26, 20111 Commission # FF 126223 ******************* **'* APPROVED BY identification and who did take an oath. ARACELYS M. HERNANDEZ MY COMMISSION # EE 192500 EXPIRES: April 27, 2016 Bonded Thal Notary Public Underwriters *** * **********;:sue, *********************** Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) t. RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY STATE OF FLOR -� , "- DEPARTMENT' OF EUEINEES.,AND PROFESSIONALS REGULATION CONSTRUCTION NDUST Y7LICENSIN gAgARD ' }.. ER r DCC1328038'..��.,�1.�.�►` , A , "1The,ROOFINIG.CONTRACTOR ".s.=-ik, .;Naed belOw1SCERTIFIED�� .y, .Undo hepovlslonsof,Cha ter,489,F5 -r y • Ex iratren;date,,AUG`31; 2018"` , """ ., GUERREROI MIGUEi�uANIGEt ',l *' ROOFII�G,CORP ,- 4337,E$11 AVE.'.`,..t. -ISSUED: 08/17/2014 g` r,,DISPLAYAS6REQUIREC BY LA Local Business Tax Receipt.. Miami -Dade County, State of Florida —THIS IS NOTA• BILL — DO NOT PAY 6029912 BUSINESS NAME/LOCATION A & J ROOFING CORP 4337 E 11 AVE HIALEAH FL 33013 OWNER A & J ROOFING CORP Worker(s) 1 RECEIPT NO. RENEWAL 6290571 LBt EXPIRES SEPTEMBER 30, 2016 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC. TYPE OF BUSINESS 196 SPECIALTY BUILDING CONTRACTOR PAYMENT RECEIVED CCC1328038 BY TAX COLLECTOR $45.00 08/05/2015 ECHECK-15-159405 This Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, permit, or a certification of the holder's qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles — Miami —Dade Code Sec 8a-276. For more Information, visit www.miamidade.aov/taxcoilectot ' CERTIFICATE OF LIABILITY INSURANCE Date 1/2/z015 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691 (727) 938-5562 This Certificate is issued as a matter of information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer A: Lion Insurance Company 11075 InsurerB: Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL ]: LIABILITY Commercial General Liability Claims Made Occur Each Occurrence $ Damage to rented premises (EA occurrence) $ Med Exp $ Personal Adv Injury $ General D aggregate limit applies per: Policy ❑ Project ❑ LOC General Aggregate $ Products - Comp/Op Agg $ AUTOMOBILE Iml LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non -Owned Autos Combined Single Limit (EA Accident) $ Bodily Injury (Per Person) $ Bodily Injury (Per Accident) $ Property Damage (Per Accident) $ EXCESS/UMBRELLA ROccur LIABILITY ❑ Claims Made Deductible Each Occurrence Aggregate A Workers Compensation and Employers' Liability Any proprietor/partner/executive officer/member excluded? NO If Yes, describe under special provisions below. WC 71949 01/01/2015 01/01/2016 x I WC Statu- tory Limits I I OTH- ER E.L. Each Accident $1,000,000 E.L. Disease - Ea Employee $1,000,000 E.L. Disease - Policy Limits $1.000,000 Other Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616 Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 91-67-590 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": A &) Roofing Corp Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 12-24-13 (TLD) Begin Date 12/12/2013 CERTIFICATE HOLDER CANCELLATION CITY OF MIAMI SHORES BUILDING DEPARTMENT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Should any of the above described policies be cancelled before the expiration date thereof, the Issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives. 0 From:Casualty Systems 305 551 0857 12/03/2015 12:51 #774 P.001/001 ,A o- CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 12/3/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Casualty Systems, Inc. 3331 SW 107 Ave Miami FL 33165 CONTACT NAME: Juan Hernandez PHONE (305)551-0590 FAX IA/C. o, Ext]; (A/C No, (305) 551-0857 ADDRIEss:admin@casualtyssystems.com INSURER(S) AFFORDING COVERAGE NAIC # INSURER A :Arch Specialty Insurance Co. INSURED A & J Roofing Corp. 4337 E 11 Ave. Hialeah FL 33013 INSURER B :Progressive INSURERC: INSURERD: INSURER E : INSURERF: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO'ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER LTR INSR WVD A B TYPE OF INSURANCE GENERAL UABIUTY X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE l C I OCCUR GEM. AGGREGATE LIMIT APPLIES PER: �► I POLICY 1-7 JFCOT n LOC AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS UMBRELLA UAB EXCESS UAB X SCHEDULED AUTOS NON -OWNED AUTOS OCCUR CLAIMS -MADE DED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' UABIUTY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below POLICY NUMBER 4OL0006863-02 02245587-2 POLICY EFF (MM/DDtYYYY) 11/28/2015 06/05/2015 POLICY EXP IMM/DD/YYYYI 11/28/2016 06/05/2016 LIMITS EACH OCCURRENCE DAMAGE TO RENTED PREMISES (Ea occurrence) MED EXP (Any one person) $ 1,000,000 PERSONAL & ADV INJURY $ 100,000 $ 10,000 $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OP AGG COMBINED SINGLE UMR (Ea accident) BODILY INJURY (Per person) $ 2,000,000 $ $ 300,000 BODILY INJURY (Per accident) PROPERTY DAMAGE (Per accident) PIP EACH OCCURRENCE 10,000 AGGREGATE Y/N N IA DESCRIPTION OF OPERATIONS / LOCATIONS I VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space is required) Roofing Contractor Lic # CCC1328038 CERTIFICATE HOLDER WC STATU- I TORY 1 MOTS E.L. EACH ACCIDENT OTH- FR $ E.L. DISEASE - EA EMPLOYEE E.L DISEASE - POLICY LIMIT City of Miami Shores Building Dept. 10050 NE 2nd Ave Miami Shores, FL 33138 ACORD 25 (2010/05) INS025 (201005).01 CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Juan Hernandez/YOYI © 1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Signature RF- 15- otq RECE7VEIi DEC 0 3 2015 BY' iami hores iliage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: e a -2 GU zeacb Property Address: k2Coq 7%e. /OCR LT )rICZrize 91/2/.D J'&/3d7 Date:�/�� Roofing Permit Number: Dear LI}�BuildingOfficial: , ', / I ),/S-T J ne itkis--/ad certify that I am not required to retrofit the roof to wall connections of my building re/he just valuation for the structure for purpose of ad valorem taxation is Tess than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) O Chi./57U'/ )e ZW,574-eld Print Name State of Florida County of Dade The undersigned, being the first duly swocrf,'d2E1t set 4nd Gaya tt ate/she is the owner for the above property mentioned. • ••••••• _ • Sworn to and subscribed before me this •; • ! ; • • • ▪ da}i of .' 1 - - - - - - - a - - - i. •dN,rPq�i �''" NA. MIGUEL A. GUERRERO . s Notary Public • State of Florida , i��� .= My Comm. Expires May 2ti, 201tt ��:;F,o���•� Commtaaion N FF 126223 ... ••. ..]• s Notary Public, Sate of Florida at Large . '%j'E:�' �Jf! ,r�/te/l� • .���:' • When the just valuation of the structure for purpose of ad valorem taxation is equal to or m▪ ore than ▪ $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. ••• • • •• •• •••• •• • • . • • • • • • • • • ••• • • • Revised on 5/21/2009 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1/20/2015 Property Search Application - Miami -Dade County Summary Report Property Information Folio: 11-3206-013-4690 Property Address: 269 NE 100 ST Miami Shores, FL 33138-2418 Owner CHRISTINE WELSTEAD Mailing Address 269 NE 100 ST MIAMI SHORES, FL 33138 USA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 4/3/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,571 Sq.Ft Lot Size 8,625 Sq.Ft Year Built 1923 Assessment Information Year 2015 2014 2013 Land Value $207,224 $181,056 $160,546 Building Value $235,607 $232,419 $193,720 XF Value $1,306 $1,322 $1,337 Market Value $444,137 $414,797 $355,603 Assessed Value $371,665 $368,716 $355,603 Benefits Information Benefit Type 2015 2014 2013 Save Our Homes Cap Assessment Reduction $72,472 Portability Assessment Reduction $46,081 Homestead Exemption $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 20 & W1/2 LOT 21 BLK 34 LOT SIZE 75 X 115 OR 18910-2767 12 1999 1 COC 21781-4223 09 2003 1 •• • • • • • • • • • • • • •• •. • • •• • • • • • •• ••• •• • Generated On : 11/20/2015 Taxable Value Information 2015 2014 2013 County Exemption Value $50,000 $50,000 $0 Taxable Value $321,665 $318,716 $355,603 School Board Exemption Value $25,000 $25,000 $0 Taxable Value $346,665 $343,716 $355,603 City Exemption Value $50,000 $50,000 $0 Taxable Value $321,665 $318,716 $355,603 Regional Exemption Value $50,000 $50,000 $0 Taxable Value $321,665 $318,716 $355,603 Sales Information Sale Previous price O Book Page Qualification Description 05/24/2013 $565,000 28649-0616 Qual by exam of deed ,05{27/2C=10 • • • • • • $310,400 27316-1492 Financial inst or "In Lieu of Forclosure" stated ;d9j01/23 $550,000 21781-4223 Sales which are qualified 12/01/1999 $290,000 18910-2767 Sales which are qualified • ••• • • • • • • • • • • • • • • • • • • • • • 1 • • T• • • • • • • • • • • • • • The Office of the Property Appraiser is continually editing updating tlitottlx roll. This weesite rfIay not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: • • • * • • • • • • • • • • • • • • • • • 4 • • • • • • • • 4 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 SECTION 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICA F Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application For INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application 1 A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concreteeor Clay Tile'? A,B,D,E 1,2,3,4,5,6,7 Metal Roofs ', A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation - RECEJVED DEC 0 3 2015 BY. 16.36 INiTERNATIUNAI'CODEiCOUNCfb • •. • • • • • • •• •. . • • • • .• •.• .• • • •••• • • • ••.•• • • • • • • • • • •• • • • • • • • i• • • • PERMIT #: '2 mt5 ,5a (g Miami Shores Villa e APPROVED EY `' DATE • •• OOPING DEPT ElL(53 DEPT SV'gJiT 10 CCMPLIANCE WITH ALL FEDERAL *T ATE ANu l,( LIN i'f HUL=S AND REGULATIONS •• • FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) Copyright to, or iicwwcd try, ICC MLla RI€HTi6FleSS2VED)ttececssed by Eliezer Palacio on Jun 8, 2015 10:32;12 AM pursuant to license Agreement. No furQler retoductits ltj4'izcd.: : .• • • • • • • • • • • • •• •• • • • •• •• • • • • • • •••'• • INTERNATIONAL• CODE"COUNCIL. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form, Section A (General Information) Master Permit No. Process No. Contractor's Name 1. KO-6 Cf 0i. -3 Job Address c.) ci °t-t", C • ., 0 ROOF CATEGORY Low / 1 l5 Slope 0 Mechanically Fastened Tile Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles 0 Metal Panel/Shingles 0 Wood Shingles/Shakes 1 0 Prescriptive BUR-RAS 150 1 ROOF TYPE 1 ❑ New roof a Repair ❑ Maintenance 0 Reroofing 0 Recovering ROOF SYSTEM INFORMATION t 1 , Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF)ATotal (SF) Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- 1 sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 IN 1 i 11. tinizil 1.--iiii ark El 7 7 - — migt-imil I. A�111 ill ill 11111111111 OM 1 Mailigil rim MUM ii A mum El . I. nom :ma, i minimii u iiii lia Ns .. sit .11.41,11 airli,,.... 111111M . NI ••••••• • .•• • • • • • • • • • • • ••• • ••• • • • FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or 1icet♦sed by, ICC (1LTZtIc -1T! Q?SEI:VED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to Liccnsc Agreement. No furtifbr repooductiolls adt*OAzcd. • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • filial • • 1 1 1 1 1 1 1 1 1 II 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 Top Insulation Fastener/Bpfip��ijng Material: Base Sheet(s)& No. of Ply(s0) 6 Base Sheet Fastener/B nding Mater al: 1f "/0, 6. `)7 i(0'V,6-Q 51. eGin/- ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer:�L/r & 't c.:1 Product Approval No.: /'4 — D 5c2 / e 9 Design Wind Pressures, From RAS 128 or Calculations: P1:40747 P2: o '7 P3: —/6211 Max. Design Pressure, from the s eciflc product approval system: al", s �CJS�� Deck: z..0f� Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): A.)/�- Anchor/Base Sheet Fastener/Bonding Mater' I: ,cJ/Ct_s Insulation Base Layer: bt./a..) Base Insulation Size and Thickness: A)/a Base Insulation Fastener/Bp/ g Material: Top Insulation Layer: Top Insulation Size and Thickness: ,tJ/CC Ply Sheet(s) & No. of Piy(s): • • Top Ply Fge/ r/na 1v[a Surfacing: /LPL' Fastener Spacing for Anchor/Base Sheet Attachment: Field: 1 " oc @ Lap, # Rows.. @ I " oc Perimeter:(t' " oc @ Lap, # Rows 1 @ 6 " oc Comer: 6" oc @ Lap, # Rows 1@ " oc Number )of asteners Per Insulation Board: Field ✓" " Perimeter i`' Corner N/Q Illustrate Components Noted and Details as Applicable: 1 1 1 1 1 1 1 1 1 1 Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, 1 Coping, Etc, Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that I Comply with ' 111 and Chapter 16. FT. 5/a arag-trA- --?(02)e eao Skid - Ay k .5,1164AVI,'d 0-6 • • • • •• • •• ••• •• • Ply Sheet Fastener/Bonding Material: • ••• • Top Pt /� ��ieda,: ••• •. 15.38 INTERNATIONAL'CODE COUNCIL° • •• • ••• • ••• • •• • • • .. • •• r• • •• •• • • • 0/ Mean Roof Height FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2044) Copyright to, or 114.441 b): ICC (4..LpliTSI SERVED); fccsscd by Elie= Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproduction auabonsed. • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1 1 1 1 1 I 1 1 1 1 i 1 1 ! 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Number: i42S4oa/nLYLJ Uvrito "` 5 Minimum Design Wind Pressures, If r Applicable (From RAS 127 Calculations): P1: �> I P1: ""� I / P1: /aD Deck Type: Roof Slope: : 12 Type Underlayment: Insulation: Ridge Ventility? 1 1 1 1 1 1 1 1 1 1 1 C�.57'rr7O G� 1 i Fire Barrier: Mean Roof Height: /09-' Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: Roof Covering: • • • • • • • Type & Size Drip Edge: ••••.•• • • • •• •• ••• •• • • • •• • ••• • ••• ••• • • • Y • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • ••• • ••• • • • 1 1 1 1 7-zi eizew Oda 't 1 1 1 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 Copyright to, ortiiiselpy, THS'S NESC.RVEDf accessed by Eliezcr Palacio on {un 8, 2015 10:32:12 AM pursuant to License Agreement. No fu*hcrrgproducgpnsfylgpnzect • • • • • • • • • • • • • •• •• • 9 • •• •• ••• • • • ••• • • INT[RNA`fIONAUCODECOUNCIL° 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from M. If the Mt values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" n (P1: N!' 5: X 79= gg,f Mg:Xea2= Mr1»5 S'9 Product Approval Mt 42, 7 (P2. a r /xX >,:7Y/yz2 - Mg:0 41= Mr/ �-'�0.5 Product Approval M1 oaf. C? (Pr../0, ` X.4�,t'''`1'7- . V'" - Mg:5709.wMadMAPIProduct Approval Mt eO/, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mt Mr required Moment Resistance` Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35,1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a Iist of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. if the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1: x L = _ x w: _ ) - W: x cos © = Frt Product Approval F' I (P2:x L _ = x w: _ ) - W: _ x cos 8 = Fa Product Approval F' I (P3:_ x L _ _ _ x w: _ ) - W: _ x cos H ^ = Fr3 Product Approval F. 1 1 1 1 Where to Obtain Information Description Symbot Where to Lind Pressure Designpared P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier 7, Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mt Product Approval Required Moment Resistance • Lla • • • • • . Calculated Minimum Attachment Resistance ; F' . •. • • e erctliu:t Approval Required Uplift Resistance _ : Fr - " ' - - - .- - ZvafcuIared • Average Tile Weight W •• Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building ofiioiai atihe time of permit ap�ilircti&r - . - - - - - 15.40 INTERNATIONAICODECOUNCIL° •. • • • . • • • • • .• • . • • • .. ..• • • • • . . • FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed% itC:ALL frFSItDj• access¢1 by Eliczer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement, No further reproductions auth.riz•d• • • • • • • • • • • • • • • • •• •• • • • •• •• •.• • • • ••• • • SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Renaifing wood decks: When replacing roofing, the existing wood roof deck may have to e renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). ;� 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance: therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. .K- / Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Owner/Agents Signature Date a7- 12 100 s7— Property Addressm2-uo Revised on 7/9/2009 LD;07/01/2015; /c7;//-5 Contractor Signature ate Permit Number •• •.• . . . . • •. • • • • • • • • • .• • • • .• • • • •• • • • • . .•. . • .• • . . .• • •• • • • • •• • • • • • • • • • • • • • • . • • • •. ••• •.• • • • • • • • • • • ... • • • • •• •• •• • • • • • • • • • • • • • •• . . . . •• • • • • • • • • • . • • • • • • ... • • • 0.• . • MIA DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CertaiiiTeed Corporation I 18 Moores Road Malvern, PA 19355 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.2ov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:tCertairiT ed Modified` Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at trvregngstaf:thy.$uiading Official. . . . . . .. . . . . • . This NOA revises NOA #14-0224.03 and consists of paps i t rook 42: • The submitted documentation was reviewed by Alex Tigera. • . • •• • . • • MIAMI•DADE COUNTY APPROVED . fr"reboo. • • • • • • • • • .... ....... . • . . • . . • . • . . . . . • . . . • .. .. . . . .. .. ... . . . ... • • NOA NoS: 14-0529.027 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 1 of 42 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -127.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions All Weather/Empire Base Sheet Flexiglas Base Sheet Flintlastic Base 20 Flintglas Ply Sheet Type IV Flintglas Premium Ply Sheet Type VI Flintlastic STA Flintlastic GTA Flintlastic GTA-FR Flintlastic GMS MIAMI•DADE COUNTY APPROVED 39 3/8" x 65'10"; Roll weight: 70 lbs. (2 squares) 39 3/8" x 98'9"; Roll weight: 90 lbs. (3 squares) 39 3/8" x 49' 6"; Roll weight: 90 lbs. (1.5 squares) 39 3/8" x 164'7"; Roll weight: 38 lbs. (5 squares) 39 3/s" x 164'7"; Roll weight: 40 lbs. (5 squares) 39 3/8" x 32' 10"; Roll weight: 87 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 105 lbs. (1 square) 39 3/s" x 32' 10"; Roll weight: 105 lbs. (1 square) Test Product Specification Description ASTM D 4601, Type Asphalt coated, fiberglass reinforced II base sheet. UL Type G2 ASTM D 4601, Type Modified Bitumen coated fiberglass II base sheet. UL Type G2 ASTM D 6163, Modified Bitumen coated fiberglass Grade S, Type I base sheet. ASTM D 2178, Type IV UL Type G1 ASTM D 2178, Type VI UL Type G1 ASTM D 6222, Grade S, Type I 39 3/s" x 32' 10"; Roll weight: 941bs. • • • • (1 square) • ASTM D 6222, Grade G, Type I ASTM D 6222, Grade G, Type I ASTM D 6164, • GTad�. G,.Txpe i • • • • • • • • • •• • 0 • •• • • • •• • •.• • • • • • •• • • • ••• • ••• • • • • ••• • • • • • • • • • •• •• • • Fiberglass, asphalt impregnated ply sheet. Fiberglass, asphalt impregnated ply sheet. Smooth surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for torch application. Granule surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for torch application. Granule surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for torch application. Granule surfaced SBS Modified Bitumen membrane with non -woven polyester mat reinforcement for mop application. • • •Y• ••• • • • • u • • • • • •• •' • • • . •• • NOA No.: 14-0529.02 • • • • • • Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 2 of 42 • • • • ••• • • • • • ••• • • • • • • • • 3 • • • • •• •• ••• • • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Flintlastic Premium GMS Flintlastic FR-P Flintlastic Premium FR-P Flintlastic FR Dual Cap Flintlastic FR Cap 30 Flintlastic FR Cap 30 T Flintlastic Base 20 T Flintlastic FR Cap 30 CoolStar Flintlastic FR Cap 30 T CoolStar MIAMI•DADE COUNTY APPROVED • e• •.. • Dimensions 39 3/s" x 32' 10"; Roll weight: 101 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 101 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 101 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 103 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 86 lbs. (1 square) 39-3/8" x 32' 10"; Roll weight: 100 lbs. (1 square) 39-3/8" x 33'; Roll Weight: 81 lbs. (1 square) 39 3/s" x 32' 10"; Roll weight: 88 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 102 lbs. (1 square) •• ••• . . e • • • • •• • • • • Test Specification ASTM D 6164, Grade G, Type II ASTM D 6164, Grade G, Type I ASTM D 6164, Grade G, Type II ASTM D 6162, Grade G, Type I ASTM D 6163, Grade G, Type I ASTM D 6163, Grade G, Type I ASTM D 6163, Grade S, Type I ASTM D 6163, Grade G, Type I ASTM D 6163, Grade G, Type I • • • •• • • •• • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • .• • • • • • • • • • • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • e• •• • • • •• •• • • • • • • • • • • • Product Description Granule surfaced SBS Modified Bitumen membrane with non -woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Granule surfaced SBS modified bitumen membrane with a nonwoven polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for torch application. Modified Bitumen, coated fiberglass base sheet for torch application. Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 3 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic GTA CoolStar 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GTA-FR CoolStar 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS CoolStar 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 97 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium GMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified CoolStar weight:103 lbs. Grade G, Type II Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic FR-P CoolStar 39 3/s" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium FR-P 39 3/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS CoolStar weight: 103 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Ultra Poly SMS 39 3/s" x 32' 10"; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. (1 Grade S, Type I Bitumen Membrane with non -woven squares) polyester mat reinforcement for mop applications. Glasbase Base Sheet 36" x 98' 9"; Roll ASTM D 4601, Type Asphalt coated, fiberglass base sheet. weight: 'lb's' • •' ' ' II, • •• (3 squares) • • .... .ILL•. pe 02 • MIAMI•DADE COUNTY APPROVED •• ••• •• • • • •• • ••• • • ••. •.. • • • • • • • • • • • • • • • • • • • • • . •• . • • . .• ••• • ••• •• • • ••• • • • . .•• • . • • • • . • • • • • • ••• • . • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 4 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED B TABLE 1 Product Dimensions Flintlastic Poly SMS Base Sheet 39 3/8" x 64' 3"; Roll weight: 90 lbs. (2 squares) Test Specification ASTM D 4601, Grade S, Type II UL Type G2 Yosemite Venting Base Sheet 39 3/s" x 32' 10"; Roll ASTM D 3909 weight: 85 lbs. ASTM D 4897, Type (1 square) II UL Type G3 ASTM D 6509 Flintlastic APP.Base T Flintlastic Ultra Glass SA Black DiamondTM Base Sheet APPROVED INSULATIONS: Product Name 39 3/8" x 65' 4"; Roll weight: 100 lbs. (2 squares) 39 3/8" x 33' 11"; Roll weight: 73 lbs. (1 square) 36" x 68'7"; Roll weight: 78 lbs. (2 squares) FlintBoard ISO FlintBoardH ISO ACFoam -II High Density Wood Fiberboard Perlite Insulation DensDeck, DensDeck Prime H-Shield ENRGY 3 ENRGY 3 25 PSI Multi -Max FA-3 SECUROCK Gypsum -Fiber Roof Board MIAMI•DADE COUNTY APPROVED ... • ASTM D 1970 ASTM D 1970 TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation homogenous fiber reinforced .. ... . • • . . •• • • • • • • • • •• • • • •• • • • •• • • • •• • • • • • • ••• • • .. • . .• . . • • .. • • • • • • •• • • • • • •• • • • • • • ••. • . • • • . . • • • • . ..• • • • . • . • •• •• • • •.• . . • ... . • • • • • • • • • • •• •• Y APPLICANT: Product Description Modified Bitumen coated polyester base sheet. Mineral Surfaced fiberglass reinforced buffer sheet. Modified Bitumen coated fiberglass base sheet. Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. Self -adhering fiberglass reinforced modified bitumen base sheet Manufacturer (With Current NOR) CertainTeed Corporation CertainTeed Corp. Atlas Roofing Corp. Generic Generic Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. Johns Manville Corp. RMax Operating, LLC USG Corp. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 5 of 42 APPROVED FASTENERS: Fastener Product Number Name 1. Trufast #12 DP Fastener 2. Trufast 3" Metal Insulation Plate 3. FlintFast #12 4. FlintFast 3" Insulation Plate 5. FlintFast #14 6. Simplex MAXX Cap 7. OMG #12 Standard Roofgrip 8. OMG 3" Galvanized Steel Plates 9. Trufast #14 HD Fastener 10. OMG Heavy Duty 11. OMG 3 in. Round Metal Plates 12. AccutTrac Hextra 13. AccuTrac Plates 14. AccuTrac Flat Bottom Plates MIAMIDADE COUNTY APPROVED TABLE 3 Product Description Insulation fastener for wood and steel decks Galvalume steel plate Coated, carbon steel screw Galvalume AZ50 steel plate Insulation fastener for wood and steel decks Polymer fastner Insulation fastener for wood and steel. Galvalume stress plate Insulation fastener for wood and steel decks Insulation and membrane fastener Galvalume AZ50 steel plate Carbon steel fastener Galvalume stress plate. A2-SS aluminized steel plate Dimensions various 3" round various 3" round various 1" long various 3" round various Various 3" round Various 3" square 3" square •. •.. . • . • . •• • • . . •• . • •. •.. •. • . • •• • .•. . . •.• •.• •• . . .• • • • • • • • • •• • • • . • . . .. • • • . • . • ••• • ..• . . . • • • . . • • • • • • • • • • • •. • • • • • . • . • . • • • • • . • . . . • . • . • .. .. . •• •• .. •• 0•• . • • 0.. . • Manufacturer (With Current NOM Altenloh, Brinch & Co. U.S., Inc. Altenloh, Brinch & Co. U.S., Inc. CertainTeed Corp. CertainTeed Corp. CertainTeed Corp. Simplex Nails, Inc. OMG, Inc. OMG, Inc. Altenloh, Brinch & Co. U.S., Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 6 of 42 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. MIAMI-DADE COUNTY APPROVED .. ... . • • • • •• • • •• • .. • • • •• • • • •• • • • •• . . ••• • • •• • • •• • •• • • • • • • • •• •• • • • • • • • •• • • • • •• • • • • • • • • • • • • • • • • • • • • • • • . • . • • • • . .•. • • • • • • • • • • •• •• • • • •. • • • • • • • • • • • NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 7 of 42 EVIDENCE SUBMITTED: Test Agency/Identifier Factory Mutual Research Corp. Underwriters Laboratories, Inc. United States Testing Company Momentum Technologies, Inc. TrinitylERD PRI Construction Materials Technologies LLC MIAMI•DADE COUNTY APPROVED Name FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 UL 790 ASTM D 5147 ASTM D 5147 ASTM D 4601 ASTM D6164 ASTM D6222 ASTM D 3909/ D 4897 TAS 114(J) TAS 114(J) TAS 117 (B) TAS 117 (B) TAS 114 (H) TAS 114 TAS 114 TAS 117 (B)/ ASTM D 6862 TAS 114 ASTM Physical Properties ASTM D6164/D4798 ASTM D4601 ASTM D1970 ASTM D5147/D4798 ASTM D5147/D4798 ASTM D1876 ASTM D1876, TAS 114 (H), TAS 117 (B) FM 4474/TAS 114 TAS 117B ASTM D4798 ASTM D4798 ASTM D6222 TAS 117, TAS 114 ASTM D1876, TAS 114 (H), FM 4474 AStik' 151t7gitAs i al)," • •F1V� 447 : � • � ' . .• ASTM•136163 • • •• ASTM D6163 • ••ASTM.D6222 • • • . • . . . • • •• . • • . . • . •• • • . • • •.• . .•. • • • •. • • • • • • • ••. • • • . • • • • • .•• . . • • • • . . • . . • •. • • • •. •• • . •.• • • Report 3Y8A1.AM 0D3A3.AM 2DOAO.AM 1D7A4.AM 3039046 3048520 R11656 97457-4 97-457-2R AX31 G8D AX31 G8F AX31G8G AX31G8C 3504.06.01-1 3507.08.99-1 3503.10.06 06490.04.07-R 1 Letter 3533.01.06 3521.07.04 C8500SC.11.07 C8370.08.08 C10080.09.08-R4 C31410.01.11-2 C40050.09.12-1 C40050.09.12-2 C31410.10.10-R1 C31410.01.11-1-R1 C35460.05.11 C42110.08.12 C39670.08.12 C35500.02.11 C31410.01.11-2A-R1 C31410.12.13 C40050.12.13-R1 C30310.12.09-R1 C45620.03.14 C47320.03.14-RI CTC-032-02-01 CTC-066-02-01 . CTC-070-02-01 • Date 03/23/96 04/04/97 12/23/98 11/09/98 06/15/10 09/19/13 01/11/13 06/03/88 12/02/87 09/05/08 06/05/09 06/05/09 09/05/08 06/05/01 04/18/01 10/10/06 06/27/07 04/05/06 01/06/06 07/29/04 11/30/07 08/19/08 03/25/10 01/10/11 09/28/12 09/28/12 11/01/12 11/01/12 06/16/11 08/13/12 08/20/12 02/09/11 02/21/13 12/05/13 12/31/13 03/07/14 03/27/14 04/01/15 01/22/08 08/09/11 08/09/11 NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 8 of 42 EVIDENCE SUBMITTED: Test Agency/Identifier MIAMI•DADE COUNTY APPROVED Name Report Date ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-162-02-01 05/09/13 ASTM D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D1970 CTC-199-02-01 01/22/14 • .. ... . . . . . .. . . . . . . . .. ... .. . . . .. • • •. • ... • • • .. • •• . •• • •• . • . • • • •• • • •• •• NOA No.: 14-0529.02 • .. • • • • • •• • • • • • Expiration Date: 06/19/18 Approval Date: 09/24/15 ••• • • • • ... • • Page 9of42 • • • • • • • • • • • ••• • • • • • • • • • • • • • • . • • •• .. • • • .•. ... • • • ... • • Membrane Type: Deck Type 1I: Deck Description: System Type E(4): SBS Modified Wood, Non -Insulated 19/32" or greater plywood or wood plank Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: Fastening: Ply Sheet: (Optional) Membrane: Surfacing: (Optional) Maximum Design Pressure: Oneply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet '•Glasb esa Base r Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Base sheet shallbe lap'p`ed 4 'andfastenedTvith lal-ga.Tannular ring shank nailTand approved tin caps 8"o.c-in the laprand three rows staggered iirthe center of the sheet 8"o.c. ' 3 One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. CO irpr of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or'FlintlastiF FR Cap'3 r Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. ti MIAMI•DADE COUNTY APPROVED •.• • Any of the approved surfacing/coating options listed in Table 4. -52:5.psf. (See General Limitation #7) •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • • • • • • • • ••• ••• • • • • • • • • • • • • •• • • • ••• • ••• • • • • • • • • • • • • • .• •• ••• • • • • • • • • •• • • • • ••• • • • • • ••• • • • • • • • • • . •• • NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 24 of 42 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED • • • • • • . • • • • • • • • • • •• • • • .O • • • •• • • • • • • • • • • •• • • • •. . • .•• • • • • • • • • •• • • •• • • • •• • •• •• •• • ••.•. • . • • • • • • • • • • • • • • • • • • • • • • • • . • • ••• • • • • . . • • • • J • • • • • • • • • • • • • • • •• •• • • • •• • • • • • • • • • • • NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 42 of 42 12/1/2015 TGFU .R11656 - Roofing Systems TGFU.R11656 Roofing Systems Home Quick Guide Contact Us UL.com Page Bottom Roofing Systems See_GentrraTITifarfrratarifor Roofing Systems CE RTAI NTE E D"CORP ��O �T Z-PR 140 7NT©N MEt 11T RD R11656 PO BOX 1100 BLUE BELL, PA 19422 USA "1/2-in. thick (minimum) gypsum board or 1-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or 1-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" are to offset a minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. '/4-in. thick (minimum) United Sates Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible roof deck in a system with any UL Classified insulation except polystyrene." Any UL Classified insulation may be used underneath Yz-in. thick (minimum) gypsum board or 1-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or'/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) in any existing noncombustible deck Classification. Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A, B or C roof constructions indicated below. Type G1 "Flintglas Ply Sheet" Type 4 or "Flintglas Premium Ply Sheet" Type 6 are suitable alternates for Type 15 organic felt; Type G2 "Glasbase Base Sheet" is a suitable alternate for Type 15 and Type 30 base sheets; Type G3 "Flintglas MS Cap" is a suitable alternate for Type 30 Cap Sheets. "Flex-I-Glas", "Premium Flex-I-Glas" or "Flintlastic Base 20 Sheet" is a suitable alternate for the Type G2 glass base and the Type 15 "All-Weather/Empire base sheet". Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place; ply and cap sheets are hot mopped in place. Two plies Type G1 may be utilized in place of one ply Type G2. "Flintlastic Ultra Glass SA" is a suitable alternate for Type G2 "Glasbase Base Sheet'. "Black Diamond Base Sheet" is a suitable alternate for Type G2 "Glass Base Sheet". "Flintlastic SA Nailbase" or "Flintlastic SA Plybase" are suitable alternates for Type G2 base sheets in Roofing Systems (TGFU) that limit cover applications to self -adhering ply/base sheets or membranes. EPS insulation followed by 1/2-in. thick cover board may be utilized in any of the following systems. .. ... . . . . . . . The "YOSEMITE Venting Base Sheet" may bei.ised irCafty;oi;tite following noncombustible deck roof systems and, where indicated, in combustible roof deck systegns.•• • • • • ••• • .. ... .. . . . .. "Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA Flintlastic APP Base T is a suitable alternatafor Typl'.GrI1ase shret:• • "Flintlastic Ultra Poly SMS" may be used in Jig: ot4Polyy MS''.E ase',iniall:a,pplication Classifications. References to Type G2 base sheets includes "Channel -Vent GB". "FlintBoard Iso", FlintBoard Iso Cold", FlintBciarcl:Iso i "o FImtBoard:Iso Plus", may be used wherever polyisocyanurate insulation is specified. • • • • •• • •• • • • . •••• •• • • . ..• .. . . .• ... . . data:text/htm I;charset=utf-8,%3Cdiv%20class%3D %22topside%22%20style%3D%22color%3A%20rgb(0%2C%200%2C%200) %3B%20font-family%3A%20V... 1/3 12/1/2015 TGFU.R11656- Roofing Systems Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. "FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate insulation is specified. "FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF" are acceptable alternatives to "FlintBoardH ISO", "FlintBoardH ISO WF" and "FlintBoardH ISO Cold", respectively, provided they do not exceed the indicated incline or thickness of the system. Any UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", "FlintBoardH ISO T WF", "FlintBoardH ISO F', "FlintBoardH ISO NB" or "FlintBoardH ISO DD" Insulation on non-combustible decks provided a minimum 1-in. thick layer of FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO DD" polyisocyanurate insulation is used. Max incline shall be in accordance with Classification established for the insulation/membrane roofing system, but cannot exceed 1:12. For Combustible Roof Decks - Class A: 1. A minimum 3-in. layer or a minimum two layers of 1.5-in. of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. 2. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed over a minimum 1 layer of Carlisle "FR Base Sheet 1S" or GAF "VersaShield FB-1S" over a combustible roof deck. The insulation is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. For Combustible Roof Decks - Class B: 1. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold", or a minimum 2-in. thick layer of Atlas "AC Foam III" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in, minimum thickness layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. Unless otherwise indicated the following memprenes•ane acceptable altsrnates for the following membranes tabulated below, limited to 1/2-in. incline: •• • ••• Membrane -- -.. •• . • • .• Acceptable Alternate Flintglas MS Cap • ••. • . . . • . . • • ••. ..• Flintglas MS Cap CoolStar Flintlastic GMS Premium • • •• ••• • • -• • . • . • • • • • • • •• • •• •• • • Flintlastic Premium GMS CoolStar Flintlastic GTS ..• • • '. • ••. • • • • - —•.• • Flintlastic Premium Flintlastic FR;DuOLEpp, f liVttlastic:Pt+erpium FR-P CoolStar or Flintlastic FR-Dual ... • • • ••• • • data:text/html;charset=utf-6,%3Cdv%20class%3D%22topside%22%20style°/a3D%22color%3A%20rgb(0%2C%200%2C%200) %36%20font-family%3A%20V... 2/3 Flintlastic GTS CoolStar 12/1/2015 TGFU.R11656- Hooting Systems FP-P Cap CoolStar Flintlastic FR Cap 30 T Flintlastic FR Cap 30 T CoolStar Flintlastic GTA Flintlastic GTA CoolStar Flintlastic GMS Flintlastic GMS CoolStar Flintlastic SA P-Cap FR Flintlastic SA Cap FR CoolStar Flintlastic GTA-FR Flintlastic GTA-FR CoolStar Flintlastic FR-P Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar Flintlastic FR-Cap 30 Flintlastic FR Cap 30 CoolStar ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT • • Class A .. ... . • . • • •• . . . . . .. ... .. • • . .. • ... • • • • • • • .. ••• • • • . • .. • . • • • • ..• • • • • • • • • • • • • •.. ... • • ... • • • • • • • • • • • • • ... • • . . • • • .... • . ••• • • • • • • • • • • • • •• .. • data:text/htm I;charset=utf-8,%3Cdiv%20class%3D%22topside%22%20style%3D%22color%3A%20rgb(0%2C%200%2C%200) %3B%20font-family%3A%20V... 3/3 *AII joints blocked with 2x4's. 12/1/2015 oonng aysterns Class A - Fully Adhered In lieu of any membrane or membrane/surfacing shown below, "Flintlastic Ultra Poly SMS", covered with gravel, may be utilized. 1. Deck: NC Incline: 1 Vapor Retarder (Optional): — Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): — One or more layers or combination of the following: UltraGard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: — One layer Type G2 "Glasbase" base sheet. Membrane: — One layer "Flintlastic GTA" (3/4-sq or 1-sq), "Flintlastic GTS" (modified bitumen), heat fused or "Flintlastic GMS", hot mopped. Surfacing: — APOC "No. 212 Fibrated Aluminum", applied at 11/2-gal./100-ft2. 2. Deck: NC Incline: 3/4 Vapor Retarder (Optional): — Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): — One or more layers or combination of the following: Ultragard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: — One layer of Type G2 "Glasbase" base sheet. Membrane: — One layer of "Flintlastic STA (modified bitumen), heat fused. Surfacing: — "FlintCoat-A150" or Karnak Corp. "97AF", applied at 11/2-gal./100-ft2. 3. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Schuller International "UltraGard Premier", polyisocyanurate, wood fiberboard, perlite, fiberglass, isocyanurate, any thickness. Base Sheet: — One or more plies of "Glasbase", hot mopped or mechanically fastened. Membrane: — One ply of "Flintlastic FR" (modified bitumen), hot mopped in place. 4. Deck: NC Insulation: thickness. Base Sheet: Membrane: Surfacing: — 5. Deck: NC Incline: 1/2 — Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened, any — Type G2, mechanically fastened or hot mopped. — "Flintlastic GTA or STA", heat fused. Henry Company LLC "Henry 520 Aluminum", applied at 1'/z-gal./100-ft2. Incline: 1/4 Insulation (Optional): — Glass fiber, perlite or wood fiber board. Ply Sheet: — Type G2, mechanically fastened. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. Surfacing: — "FlintCoat-A150" or Karnak Corp. "97AF", applied at 1-gal./100-ft2. 6. Deck: NC Incline: 1 Insulation: — Polyisocyanurate, glass fiber, perlite, wood fiber, mechanically fastened or adhered with roofing asphalt, any thickness. Base Sheet: — Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: — "FlintCoat-A150" or Karnak Corp. "97AF", applied at 21/2-gal./100-ft2. 7. Deck: C-15/32* ••tncf4Fid t • • • • •. • ... .. • • • .. • . .• hot Insulation: — Glass fiber, perlite, 3/4-in. minimum, joints in insulation must be offset a minimum of 6-in. from joints in roof deck, mechanically fas.tegedi• •• ••• ••. •.. Base Sheet: — Type G2, mechanical�y faltenedor adhered uJith rot roofing asphalt. Membrane: — "Flintlastic GMS", ad hexed eneith hot robfaJa$ppalq. Surfacing: — "FlintCoat-A150" or Karnak Corp. 7AI'", applied at 21/2-gal./100-ft2. 8. Deck: NC •: Irijclinc::/t •: • : Insulation: — Polyisocyanurate, glas5;fjble, p�rlit�f wa d:ibex: mechanically fastened or adhered with hot data:text/him I;charset=utf-8,%3Ccenter%20style%3D%22color%3A%20rgb(0%2C%200%2C%200)%3B%20font-family%3A%20Verdana%2C%20Arial%2C%... 1/8 12/1/2015 117r V.n 1 IUw- nwm iv.�ya�oino roofing asphalt, any thickness. Base Sheet: — Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused in place. Surfacing: — "FlintCoat-A150" or Karnak Corp. "97AF", applied at 3-gal./100-ft2. 9. Deck: NC Incline: 1 Insulation (Optional): — Perlite, glass fiber, polyurethane, polyisocyanurate, phenolic combination isocyanurate/perlite, polyurethane/perlite or wood fiber, any thickness, hot mopped or nailed. Membrane: — "Flintlastic STA", "GTA", "GTA Black Diamond", "Flintlastic GTA White Diamond", "GMS", "GMS- 5M", "GMS Double Coverage" or "GMS Premium", heat fused or hot mopped in place. Surfacing: — Grundy Industries, Inc. "al MB Aluminum Roof Coating" applied at 1 to 2-gal./100-ft2. 10. Deck: C-15/32 Incline: 1/4 Insulation (Optional): — Any thickness polyisocyanurate, glass fiber or perlite, mechanically fastened, joints in insulation must be offset minimum 6-in. from butt joints in roof deck. Base Sheet: — Type G2 base/ply sheet, mechanically fastened or hot mopped. Ply Sheet: — Type G2 base/ply sheet, mechanically fastened or hot mopped. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA White Diamond" or "GTA Black Diamond". Surfacing: — Grundy's "al MB Aluminum Roof Coating" applied at 1 to 2-gal./100-ft2. 11. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened. Base Sheet: — Type G2 "Flintlastic Base 20", mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 12. Deck: C-15/32* Incline: 1/2 *All joints in deck blocked with 2x4's. Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened. Base Sheet: — Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 13. Deck: NC Incline: 1/2 Insulation (Optional): — EPS, any thickness, covered with minimum 1/2-in. thick perlite or wood fiber, mechanically fastened. Base Sheet: — Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 14. Deck: NC Insulation: fastened. Base Sheet: Ply Sheet: — Membrane: Surfacing: — Incline: 1/2 — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically — Type G2 or "Flex-I-glas", adhered with hot roofing asphalt. "Poly SMS Base Sheet", adhered with hot roofing asphalt. — "GMS", adhered with hot roofing asphalt. "FlintCoat-A150" or Karnak ore. CZ'9F" yA•ad�/z pljedtt 2-gal./100-ft . • • • •• •• •• • • • • 15. Deck: NC • • fncW%e:•�,/4' . ` .. • Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened or adhered %NON hor-oofilt„a0balt. ••: •:• Base Sheet: — Type G2 or Flex-I-glaz", :ne;hapicatIy faAiled car- adhered with hot roofing asphalt. Ply Sheet (Optional): — Type G2 oi::FlerI-glass, trIgcharrcallyfestened or adhered with hot roofing asphalt. Membrane: — "Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: — Asphalt Products Oil Corp. "APOC-400 Sunbrite" applied at 3-gal./100-ft2. Iricl`n4: iia ` ` 16. Deck: C-15/32 • •• •. •• • •• ••`•• ... • • • ... • • data:text/html;charset=utf-8,%3Ccenter%20style%3D%22color%3A%20rgb(0%2C%200%2C%200)%3B%20font-family%3A%20Verdana%2C%20Ariel%2C%... 2/8 12/1/2015 117rv.R 1 IVJu - nwlilly vyome nu Insulation: — Glass fiber, perlite, 1-in. minimum, joints in insulation must be offset minimum of 6-in. from butt joints in roof deck, mechanically fastened. Base Sheet: — Type G2 or "Flex-I-glas", mechanically fastened or adhered with hot roofing asphalt. PIy Sheet (Optional): — Type G2 or "Flex-I-glas", mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: — Asphalt Products Oil Corp. "APOC-400 Sunbrite", applied at 3-gal./100-ft2. 17. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate perlite, glass fiber or wood fiber, any thickness, mechanically fastened or hot mopped in place. Base Sheet: — One or more layers of Type G2 or "Flex-I-glas", mechanically fastened or hot mopped in place. Ply Sheet (Optional): — One or more layers or Type G1, Type G2 or "Flex-I-glas", mechanically fastened or hot mopped in place. Membrane: — "Flintlastic GTA", "GTA Black Diamond", "GTA White Diamond" or "STA", heat fused. Surfacing: — "FlintCoat-A150" or Karnak Corp. "97AF", applied at 11/2-gal./100-ft2. 18. Deck: NC Incline: 1/4 Insulation (Optional): — Perlite, glass fiber, mechanically fastened or hot mopped in place, 2-in. maximum thickness. Base Sheet: — One or more layers of Type G2 "Flex-I-glas", mechanically fastened or hot mopped in place. PIy Sheet (Optional): — One or more layers of Type G1, Type G2, "Flex-I-glas" or "Poly SMS Base Sheet", mechanically fastened or hot mopped in place. Membrane: — "GTA", "GTA Black Diamond", "GTA White Diamond" or "STA", heat fused. Surfacing: — APOC No. 212 Aluminum Coating, applied at 11/z-gal./100-ft2. 19. Deck: C-15/32 Incline: 1/2 Insulation: — Glass fiber or perlite, minimum 1-in. thick, mechanically fastened or hot mopped in place. Base Sheet: — Type G2, "Flex-I-Glas" or "Flintlastic Base 20", mechanically fastened or hot mopped in place. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", hot mopped in place. 20. Deck; NC Incline: 2 Insulation (Optional): — Perlite, glass fiber, polyurethane, isocyanurate, phenolic, combination isocyanurate/perlite, polyurethane/perlite or wood fiber, any thickness, mechanically fastened or hot mopped in place. Base Sheet: — "Flintlastic Base 20", Type G2 or "Flex-I-Glas", mechanically fastened or hot mopped in place. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", hot mopped In place. 21. Deck: C-15/32 Incline: 1/2 Insulation: — Glass fiber or perlite, min 1 in. thick, mechanically fastened or hot mopped. Base Sheet: — "Flintlastic Base 20", mechanically fastened or hot mopped. Membrane: — "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 22. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened (joints in insulation must be offset 6 in. from joints in deck). Base Sheet (Optional): — "Poly SMS Base Sheet", fully adhered with hot roofing asphalt. Base Sheet: — "Flintlastic Base 20", mechanically fastened or fully adhered with hot roofing asphalt. PIy Sheet (Optional): — One or more plies• f Dv G1, Type G2, "Flex-I-Glas Base" or "Flintlastic Base 20", fully adhered with hot roofing asphalt. • • • GGGGG • • Membrane: — "Flintlastic FR Cap 30", fully adhered ISpl;rdpfing asphalt. 23. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Glass fiber•or eerlitel 'Y►ot•fiwppddbr'rjl2chanically fastened, any thickness. Base Sheet:One or more layers oAdf.'Flex-I1.Glas" br: Fintli3sticase 20", adhered with Henry Company LLC "No. 200"or "HE #902 Permanent Band hesivezapat: piied i/zvc.�al./100-ft 2. PIy Sheet (Optional): — One or more layers of Type G1, Type G2, "Flex-I-Glas", "Flintlastic Base 20" or "Poly SMS Base Sheet", mechanically attacilecL or adhered with Henry Company LLC "No. 200" or "HE #902 Permanent Bond Adhesive", applied at :1/21gal./!1.00-;t2Ir aiihered with hot asphalt. Membrane: — "Flintlastic FR Cap 30", adhered wit�t t<lenIy c o i any LLC "No. 200"or "HE #902 Permanent ••• • • • ••• • • data:text/html;charset=utf-8,%3Ccenter%20style%3D%22color%3A%20rgb(0%2C%200%2C%200)%3B%20font-family%3A%20Verdana%2C%20Arial%2C%... 3/8 12/1/2015 I (it U.K11b b - Koonng systems Bond Adhesive", applied at 11/2-gal./100-ft2 or hot mopped. 24. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, glass fiber or perlite, hot mopped or mechanically fastened, any thickness. Base Sheet: — One or more layers of "Flex-I-Glas" or "Poly SMS Base Sheet", "Flintlastic Base 20" or Type G2, mechanically fastened or adhered with Henry Company LLC "No. 200" or "HE #902 Permanent Bond Adhesive", applied at 11/2-gal./100-ft2. Membrane: — "Flintlastic FR Cap 30", adhered with Henry Company LLC "No. 200" or "HE #902 Permanent Bond Adhesive", applied at 11/2-gal./100-ft2. 25. Deck: NC Incline: 1/2 Insulation (Optional): — Glass fiber, perlite or polyisocyanurate, hot moped or mechanically fastened, any thickness. Base Sheet: — One or more layers of "Flex-I-Glas" or Type G2, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more layers of Type G1, Type G2, "Flex-I-Glas", "Flintlastic Base 20" or "Poly SMS Base Sheet", mechanically attached or hot mopped. Membrane: — "GTA Black Diamond", "GTA White Diamond", heat fused. Surfacing: — Henry Company LLC "Henry 520 Aluminum", applied at 1'/z-gal./100-ft2. 26. Deck: NC Incline: 1 Insulation (Optional): — Any thickness, one or more layers UL Classified perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite, EPS/wood fiber, EPS/perlite, EPS/composite or Partek Insulation Inc. "PAROC" roof insulation. Base Sheet: — One or more layers Type G1 or Type G2. Membrane: — One or more layers "Flintlastic GTA" or "Flintlastic-STA" (modified bitumen), heat fused. Surfacing: — Fields Corp. "F530 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating", applied at 1'/z-gal./100-ft2. 27. Deleted. 28. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Glass fiber or perlite, hot mopped or mechanically fastened, any thickness. Base Sheet: — One or more layers GS Roofing Products "Flex-I-glas" or "Flintlastic Base 20", fully adhered or spot mopped with Henry Company LLC "MBA Gold Adhesive"applied at 11/2-gal./100-ft2 or mechanically fastened. Ply Sheet (Optional): — One or more layers Type G1, Type G2, GS Roofing Products "Flex-I-glas", "Flintlastic Base 20" or "GS Polybase", adhered with Henry "MBA Gold Adhesive". Membrane: — GS Roofing Products "Flintlastic FR Cap 30", adhered with Henry "MBA Gold Adhesive" applied at 11/2-gal./100-ft2 or hot mopped. Incline: 1/2 isvInsulation;(Optional). --Isocyanurate, 2 in. min, glass fiber'1 in. min: z41047 Base Sheet: 4,7 T.wo"or ore layers Type G2 "Glasbase", fi`rst lay"e`r mechanically fa tened. Membrane: Onelayer."GTA/FR",)torch applied. "„, 3 - 2 Incline: 1/2 Insulation (Optional): — Isocyanurate, 2-in. minimum, glass fiber 1-in. minimum. Joint Treatment: — Two in. wide aluminum foil tape adhered to the plywood joints. Base Sheet: — One or more layers Typp,GG."GLa sbase ", mechanically fastened. Membrane: — One layer "GTA/FR", to:ch appied 31. Deck: NC • • • • • • • • •• nclirte:•.�/f • • • •• Insulation (Optional): — Polyisocyanurate, glass fiber, wood fiber, perlite, mechanically fastened or hot mopped in place. • • • • • • • • • Base Sheet: — One or more layers'Fype L2 base see4t,.rnetharQcaliy fastened or hot mopped in place. Ply Sheet (Optional): — One or more la;ers 1,,,pe t,1', met tniVily fastened or hot mopped in place. Membrane: — One layer "GTA/FR", torch applied. 32. Deck: C-15/32 �• rclin�: ••• • •• • •••• •• •• • •• • • •• •• •• •• • • • •• ••• •• • • •••,• ••• • • • ••• • • data:text/html;charset=utf-8,%3Ccenter%20style%3D%22color%3A%20rgb(0%2C%200%2C%200)%3B%20font-family%3A%20Verdana%2C%20Arial%2C%... 4/8 MIAMI COUNT DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Santafe Tile C_o_r'poration'r j 8825 NW 95te Street Medley, FL 33178 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.Eov/pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. rs�Ff'Y •...«.r ...,.......�..w+ 'flt �—ve -gar w�.-,ate-wys-ra.�at�.^ rn DESCRIPTION: Santafe Spanish `SC1ayARoof The LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the j ob.Site aartie:relaugst.ofithr Bidding Official. • • .•. •. •• • •. • • • This replaces NOA# 10-1005.15 and conSi$tS gf i ages'1 nough ... • The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED •. • . .• • • •• • • '• .•• ••. • • • • • •-• • • • • • • • •• • • • .•• • . • •• • •• • • • • • • •••• •• • . • . • ••• . • • • • • • •• •.• . ••• • • • • ••• • • . •• •. •. • • • • NOA.No.:;12--0210.01 Expiration Date:02/01/16 Approval Date: 05/31/12 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Deck Type: Roofing Roofing Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Santafe `S' Clay Roof Tile Trim Pieces Dimensions L = 18" W=11.1" 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies MIAMI-DADE COUNTY APPROVED •• • • • ••• • • • Test Product Specifications Description TAS 112 One piece high profile clay roof tile equipped with two nail holes. For nail -on, mortar set and adhesive set applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Identifier 94-156-8 94-156-9 25-7205-1 Project: 07-07-00-91 (307023) 7161-03 Appendix II 7161-03 Appendix III • • P 0402 • •• OOOO • • •• • • • • • •• • • • • • • ••• • • • • • • • •• • • • • • • • • • • • •'• •• • • • •• • ••• • • • • •• • • • • • . • • • • • • • • • • • •• • • • • • • •• • • • •• •• • • • • • • • • •• Test Name/Report TAS 101 TAS 102 TAS 101 TAS 100 TAS 108 (Nail -On) Static Uplift Testing TAS 102 & TAS 102(A) Withdrawal Resistance Testing of Screw vs smooth shank nails Date Aug. 1994 March 1995 Sept. 1994 Dec. 1991 Dec. 1991 Sept. 1993 NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 2 of 5 ••• • 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date Redland Technologies P .0647-01 TAS 108 Aug. 1994 (Mortar Set) Redland Technologies P 0631-01 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 IBA Consultants, Inc. 2353-71 TAS 101 09/22/03 IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7;12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe 'S' 6.7 1.5 0.958 MIAMI•DADE COUNTY APPROVED •• • • • • • • • •• • • • • •• • • • • •• • • • •• • • • •• • • • •• • ••• • • •• • • • •• • • • • • • • • •• • • • • •• • • •• • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • ••• •• • • • • • • • • • • • • • • • • • ••• •• NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 3 of 5 Table 2: Aerodynamic Multiplyers— Mft3) Tile X (ft3) a. (ft3) Profile Batten Application Direct Deck Santafe 'S' 0.274 ( . 0.297 1 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 2":12" 3":12" 4":12" 5"•12" 6"•12" 7"•12" greater Battens or Direct Deck Battens Direct Deck Battens Direct Deck. Battens Direct Deck Battens Direct Deck Battens Direct Deck Santafe 'S' 5.93 5.90 5.85 r 5:824 5.73 5.69 5.56 5.53 5.32 5.29 5.03 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck Battens Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.161'` N/A Two #8 Screws 38.28' N/A One #8 Screw w/ Clip 57.311'z N/A Two #8 Screws w/ Clip 57.60' 61.77' 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Tile Bond 38.9i Polyfoam Polypro AH 160TM 28.54 2 See manufactures component approval for installation requirements. 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) . for Sing e Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Polyfoam Polypro AH 160Tm 63.8y Polyfoam Polypro AH 160T"" 1 61.9'4 5 Paddy placement of 63 grams of Polypro AH 160TM. 6r-"Paddyplacement of.24-grams-of'Polypro-AH :160TM. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) ford1llorfaR or Adh:si' eSet Systems • •• • • • • • Tile ••• " • • • • ••• il•e•• ••• • •• • • • Application ••• • •• Attachment Resistance Santafe 'S' Mortar Set 23.6 MIAMI•DADE COUNTY APPROVED • • • • • • • • • • • • • • •• • •• • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • •• • •••• •• •• •• • • • •• • •• • • • • •• •• • • •• •• ••• •• • • •• • • • • • • NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED 18" PROFILE DRAWING When using one screw use this hole. " SANTAFE S" CLAY ROOF TILE • • 000 • • • • • • . • • ENV OF 411i6 icttrtANCE • • • . • . • • • . .• ... .. • • • .. • 000 • • 000 0,00 • . . • • • • • • • • • • • • • • • • • • •• • • • • • •• 000 • • • • •• • • 000 • • • • • . • • • • . •• •• • • • • • • • • • . • • • . • •• • • • . •. • • • • • .• 00 • • • •• •• • . • • • • 000 • • NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 5 of 5 MIAMI colt ty DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/economv 3M Company) 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:.3MTM 2-Component.Foam-Roof Ti1e,Adhesive AH;160 e, '`1" LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job siJ al Ale requess ofthn Building Official. • • • • • • • • This NOA revises NOA 13-0502.02 and con§ists•ef eiei 1 h h• l 1. The submitted documentation was reviewed byA1 x Tigers. • • • • MIAMIDADE COUNTY ••.:,41145, APPROVED • • • • •• • • • • • •• • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • •• •• NOA No.: +14-0805.01` Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using 2-Component Foam Roof Tile Adhesive AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product 3MTM 2-Component Foam Roof Tile Adhesive Ali-160 Foam Dispenser RTF1000 ProPack® 30 & 100 Dimensions Test Product Description Specifications N/A TAS 101 Two component polyurethane foam adhesive N/A Dispensing Equipment N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Note: Test Results ASTM D 1622 1.6 lbs./ft.3 ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise ASTM D 1623 28 PSI Parallel to rise ASTM D 2127 0.08 Lbs./Ft2 ASTM E 96 3.1 Perm / Inch ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks • • • • • • • • • -. 6.Q%o Volume Change @158°F., 100% Humidity, 2 • tverks 'ASTM fl 2s 6::• :6°A. •. •3. •• • • • •. The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods anI ar esubject to normal manufacturing variation. MIAMI.DADE COUNTY :44e', APPROVED • • •• • • • • • • • • • •• • •• • • • • • • • • • •• • • • • • •• ••• • ••• • • • ••• • • • • ••O • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 0041 • • • ••• • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Test Identifier #94-060 257818-1PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 Ramtech Laboratories, Inc. 9637-92 Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services 01-6743-011 01-6739-062b[1] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to 2. 3MT` 2-Component Foam Roof Tile Adhesive AH-160 s 3. Minimum underlayment shall be in compliance with the 4. Roof Tile manufactures acquiring acceptance for the use 160 roof tile adhesive with their tile assemblies shall test 5. All products listed herein shall have a quality assurance Rule 61G20-3 of the Florida Adminie.tratiwe Code.. • • •• •••.• • . • • MIAMMADE COUNTY APPROVED • . • Test Name/Report Date TAS 101 04/08/94 TAS 101 12/16/96 SSTD 11-93 10/25/95 SSTD 11-93 11/02/95 SSTD 11-93 12/12/95 ASTM D 1623 02/01/94 ASTM E 108 04/30/93 ASTM E 108 11/16/94 ASTM E 84 01/16/95 TAS 114 03/14/96 ASTM D 1623 04/18/12 TAS 101 02/21/12 TAS 123 TAS 101 10/23/98 TAS 101 12/28/98 TAS 101 03/02/99 the Prepared Roof Tile Assembly for fire rating. hall solely be used with flat, low, & high tile profiles. Roofing Application Standard RAS 120. of 3M7'' 2-Component Foam Roof Tile Adhesive AH- in accordance with TAS 101. audit in accordance with the Florida Building Code and • .• •• • • • • • • . • .• • ••. •• • • •• • •• • • • • • •• • •• • • • • • • • • • • • • • • • • • • • • • ••• • ••• • • • .•• • • • • ..• • • • • • • • • • • • • • • • • • • • • • • • •• . • • • • • • • • . • • • • • • • . 000 • • • 000 • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. MIAMI•DADE COUNTY APPROVED .. ... . . . . . 00 . • • . • • • • • .. •.. .. . . •• • • . • . ••. •.• • • • • • • • • • •• NOA No.: 14-0805.01 • • •• • • •• •• • • • • • • • • • Expiration Date: 05/10/17 • ..• • . • • •.• •• . • . •• • . • • • • • . • • • • • • • • • • • • • • • • • • .. • • • • • • • 0 0 0 • • • 0 0. • • Approval Date: 09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at overlap 12 grams per paddy Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal edge) 20-25 sq. inches each bead 17 grams per bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENT: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY ,4 APPROVED ArSE • • •• • •• • • • • • • • • •• • • • •• • • • •• • • • •• • ••• • • ••• ••• •• • • •• • •• • • • • • •• • •• • • • • • •• • • • • • •• ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • •• • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 5 of 11 ADII ESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile 1Nall thrauglx Mast+ cement Ia�heti required) it 31w.wid,* `Az:. Batiearsaptior,A1 ;; veaayrsc rogiglt.I is c+rinttF•,.. ''`••.. i'•. _.-•'-moo"~V MIDADE COUN APPROVED • , " Vtt'u dl"-. • • • • • • • �• • I. 41,e d b.s. r>e • 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the rave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • • • • • • • • •• • 000 • • 000 •.. • • • • • • • • • • • • • • • • • • • • • • • • • • • 410 • • • • • • • ••• • ••• • • • • • • • • • ••• • • • • • • • • • •• •• • • •• • ••• • • • • • • • •• • • • • • • • • • • • • • • • • 000 • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 6 of 11 Am 1?SIVE PLACEMENT DETAIL # 2 RAiEtil<Frpi1940.4,4tim„w• Pat:dy •.:; TIM (when requared;, t� "Fascia silthronlir• tticarrr..•n7 MIAMI-DADE COUNTY APPROVED •• • • • • • • • • • • • • Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. • (Instructions continued on next page) •. ••. •. • . • •• • ••• • .•• • • • . • • • • • . •• • • • • • • • • •• • • • • • • • • • •• • • • • • •• ..• • •.• • • • • • • ..• • . • • • • . • • • ..• • • • • • • • . • • • • . • • • •• •• •.• . .•. • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 7 of 11 MIAMI•DADE COUP APPROVED ADHESIVE ;' LACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. .. • • • • • • • . .. • • • . • • • • .. ..• .• . • . •• • • . •• ••• •.• • . • .• . •• . . • • • • • . • • . • • • • •• • • •• • • •• • • • • • • • • • • .•• . . • . ••. . • • . • . • •. • • •• . • ... • • • • • •• • • . • • • • •••• •• • • •• •• ••. •• • • • • • • •• ••• • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 t!Low Profile. T Nail through pia (whan required) Battens \ optional Siegler .1d• ontopy• rile "Y f* -.fix Sinalepaddy ort und_cta j ment; Eave Course MIAMI•DADE COUt PPROVED DITESIVE PLACEMENT DETAIL # 3 Single p: Uri iertaa adium PratlUGT;'. tyrgbetween tiles) ddytundertile) 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a4" (101.6mm) x4" (101.6mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in2 (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) .. ... . . . . . .. • • . . • . .. ... .. • • . .. . • ... . . ..• . . •• • . • .. •• • • .. . • It.• .•• • •. .. •.. •• • ..• . • . . .. ... •• •••• .• . . . • • • • • . • ... • . . • . • • ...... ... • • . • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 ADHES [ : ''LACEMENT DETAIL # 3 (CONTINUED) Nail through.pla=._.r .rent_...Single p='dyu Jetti[e {when required j tbetweentites1 2addyiundertile} Battens optional to in. 1419hProfi# TII; MIAMI.DADE COUr ,,,�•..OVED ply„ asda Weephote Ewe donne )tip edge •• ••• • • 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • • •• • • • • • • • • •• • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • .•• • • • • • • • • • • • • • ••. • • • • • •• • •• • • • • • • • •••• •• • • •• •• ••• •• • • • • • • •• • • • • • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 10 of 11 11IIESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough ad' In Contact with the 2)Turn covers upsi. to in. from outsid - Then install the tile. 25sq. in. contact a: Underiayrnen• Eave clo,ure (motar s'S awn) Weepho Fascia. Remove top portio: pan tilos. Ensure e.. MIAMI [3i '' E CCti. to achieve 65 to 70 s n.Pfaceadhesivein r of cover tile. re 20 to eave course cover t ' of pan and cover tit ce Barret - Hig . teep pitch application .+hen required) Sheathing to second course of h at eave line. • 1e Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. 1) OF TIIIS ACCEPTANCE •• ••• • • • • • •• • • • • • • •• • • • •• • • • •• • • • • • •• • • ••• • • •• • • • •• • •• • • • • • • •• •• • • • •• • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 11 of 11 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ¶Polyglass USA Incr '150 Lyon Drive Fernley, NV 89408 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:1Polyglass Polystick;Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job siteiat:hs r.qulst of he.Building Official. • • • This revises NOA #12-0713.02 and cons is.of gas ? tk-ougni '. • • • • The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED • • • • • 0 • • • •• • • • • • • • it• • • • • • •• • • •• • • • • • • ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• • • • • • • • • • • • • NOA No.: 14-071.7.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Polystick IR-Xe Manufacturing Location #1 & #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 MIAMI•DADE COUNTY APPROVED Test Product Dimensions Specification Description Roll: TAS 103 A homogeneous, rubberized asphalt waterproofing 65'8" x 3'3 3/8" membrane, glass fiber reinforced with polyolefinic 60 mils thick film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 60 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'3 3/8" 60 mils thick TAS 103 ASTM D 1970 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. TAS 103 and ASTM A rubberized asphalt self -adhering, glass- D 1970 fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. TAS 103 and ASTM A rubberized asphalt waterproofing membrane, D 1970 glass-fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. TAS 103 and ASTM A rubberized asphalt self -adhering, glass- D 1970 fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. TAS 1D3•and ASZM A rubberized asphalt self -adhering, glass- D 9'70: • • fberkolyester reinforced waterproofing • piCmkttne. Designed as a metal roofing and roof tile underlayment. • ... • .•• •.. • •• • . • • •• • • • . .. • • • • • • • • • •. • • • . . .. •.• • •.• • . • • • • . • • • ••• • • • • . • • • • • • ••• • • • • • • • • • • • • • • • • • • • • . • 00 • • • • 090 • • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 2 of 9 PRODUCTS DESCRIPTION: Product Polystick TU Max Manufacturing Location #2 Elastoflex S6 G Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Test Specification TAS 103 and ASTM D 1970 Product Description A rubberized asphalt self -adhering, polyester reinforced waterproofing membrane. Designed as a a roof tile underlayment. Roll: TAS 103 and ASTM Polyester reinforced, SBS modified bitumen 32' 10" x 3' 3-3/8" D6164 membrane with a burn off polyethylene or sanded back face and a granule top surface. For use in roof tile underlayment systems. MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Trinity' ERD PRI Asphalt Technologies Momentum Technologies, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier P10870.09.08-R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390. 08.12-1 P40390.08.12-2 P40390.10.12 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX14E8A DX D 3:: D)Zi3D8r4 •.: Test Name/Report TAS 103 TAS 103/ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G155 TAS 110/ASTM D4798 & D1970 TAS 103 & TAS 110 ASTM D 1623 ASTM D 1970 ASTM D6164 TAS 103, TAS 110 & ASTM D1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 .T.,143/e1STM D4798 & G155 Tl►iI'g37 TM D4798 & G155 .. ... •• . . . .. • • • • • • • • • .. • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • Date 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 08/06/12 08/07/12 10/03/12 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 09/29/06 12/10/07 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 3 of 9 INSTALLATION PROCEDURES: Deck Type 1: Deck Description: System Type E(1) Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(2) Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(3) Anchor/Base Sheet: Fastening: Ply Sheet: (Optional) Membrane: Surfacing: MIAMI•DADE COUNTY APPROVED Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Polystick membranes self -adhered. See General Limitations Below. Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Elastoflex S6 G, hot asphalt applied. See General Limitations Below. Wood, non -insulated Min. 19/32" plywood or wood plank Base sheet mechanically fastened deck, subsequent cap membrane self- adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Polystick TU Plus, self -adhered. See General Limitations Below. •. • • • • • . • • •• • • . . • .. • •.• .. . • . .. • ... • • ..• ... •• . • . • .• • . • • • •• • • ••.• • . •. • • • . .• ••. •• ..•• • . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• • • • • • • ••• • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 4 of 9 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-Y2" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, Polystick MTS Plus, Polystick TU Plus, Polystick Tile Pro and Polystick Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (da's) MTS IR-Xe Elastoflex S6 G TU Plus TU P } Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL. 180 90 180 • • • • _ 'No : : • •I •• • I • is0 : • • • • • ••I : • i g0 . • • 180 90 180 PA. N/A 90 N/A • • • •? 0 • •' •Hazelton, •N/A' • •NIA N/A N/A N/A 7. All products listed herein shall have a quality issuranne at>,dit in mor4lace with the Florida Building Code and Rule 9N-3 of the Florida Administrativrr Cod4 • •• •• •• . • ; •• • •• • • • • •• • • ••• •• • • • • •• ••. •• •••• • •• • MIAMI•DADE COUNTY APPROVED ••• • • • • ••• • • • • • • • • • • • ••• • • • • • • • • • • • • •• •• • • • •• • ••• • • • ••• • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 5 of 9 A ) J 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU Plus, Polystick Tile Pro, Polystick TU Max or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9a. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Elastoflex S6 G Polystick TU Plus, TU P, Tile Pro, Dual Pro Polystick TU Max Polystick MTS Plus' Flat Tile Prohibited without battens 4:12 No limitation No limitation 5:12 Profiled Tile Prohibited without battens 4:12 No limitation No limitation 4:12 The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. 'The following limitations shall be apply when using Polystick MTS Plus: • Slopes up to those shown in the table above will require stagging of tiles — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles. (See Figure 1 below) • Battens shall be used for stagging of lugged tiles above 4:12 • Battens shall be used for stagging of flat tiles above 5:12 J/ Slope Figure 1: Stagging Method 9b. There shall be no roof slope limitation for the Polystick MTS Plus / Polystick TU Plus two-ply underlayment system when a applied using the stagging method outlined above. MIAMI•DADE COUNTY APPROVED .. ... . . . . . .. . • . . • • • .. .•• •. • • • .. • ••• . . ••• ••• • . • •• • •• • • • • • • • •• • • • • • • • • • • • • • • • • ••• • ••• • • • • • • • • 0.10 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 6 of 9 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. FloOt UeCK prepared with POLYSIICKTU Plus Rooting Tiles (6 Max. Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, Polystick MTS Plus, Polystick IR-Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, Polystick MTS Plus, Polystick IR-Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, Polystick MTS Plus, Polystick IR-Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMI•DADE COUNTY APPROVED • • • • • • • • . • • . • • • ••• • • ••• . • ..• ..• •• • • •• • •• • • • • • • •• • • • • • • • 410 • • • • . • • ••• . •.• • • • ••• • • • • •.• • • • • • • • • • • • • • 000 • • • • • • • • • • • • • • • • • • • • • • • • • 11110 • • • 600 • • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 7 of 9 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 61/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. MIAMI•DADE COUNTY APPROVED •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • • ••• ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • ••• • • • ••• • • • • ••• • • • • • • • • • • • ••• • • • • • • • • • • • • •• •• • • • • •• ••• • • • ••• • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 8 of 9 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. MIAMI•DADE COUNTY APPROVED END OF THIS ACCEPTANCE 3• ••• • • • • • •• • • • • •• • • • •• ••• •• • • • •• • ••• • • ••• ••• • • • • • • • • • • • • • • • • •• • • • • • • • • • •• • • • • at •• ••• • ••• • • • ••• • 4 • • ••• • • • • • • • • • • • • • • . • • • V • • • • . • • • • • • •. .• • • • •• •. .•• • • • ..• • • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 9 of 9