RF-18-1810Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
Permit
Issue Date: 7/3/2018
Permit NO. RF-7-18-1810
Permit Type: Roof
Work Classification: Flat
Permit Status: APPROVED
Expiration: 12/30/2018
Parcel Number
Applicant
930 NE 99 Street
Miami Shores, FL
1132060143390
Block: Lot:
JESSICA J BERTHIN
Owner Information
Address
Phone
Cell
MICHAEL G JOHNSON
930 NE 99 Street
MIAMI SHORES FL 33138-
(305)772-7954
930 NE 99 Street
MIAMI SHORES FL 33138-
Contractor(s)
T&S ROOFING SYSTEMS INC.
Phone
305/265-2654
CeII Phone
Valuation:
Total Sq Feet:
$ 2,800.00
400
Type of Work: Re Roof
Additional Info: RE -ROOF FLAT.
Classification: Residential
Scanning: 3
Fees Due
Bond Type - Contractors Bond
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee - New Roof
Scanning Fee
Technology Fee
Amount
$500.00
$1.80
$3.75
$2.50
$0.60
$250.00
$9.00
$2.40
Total: $770.05
Pay Date Pay Type
Invoice # RF-7-18-68122
07/03/2018 Check #: 34802 $ 770.05 $ 0.00
Bond #: 3817
Amt Paid Amt Due
Available Inspections:
Inspection Type:
Tin Cap
Final Roof
Roof in Progress
Renailing Affidavit
Review Roof
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the oreg g information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Futhermore, I author e f e above -named contractor to do the work stated.
Authorized Signature: Owner / A
licant / Contractor / Agent
July 03, 2018
Date
Building Department Copy
July 03, 2018
1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Inspection Number: INSP-000659-2018 Permit Number: RF-7-18-1810
Scheduled Inspection Date: October 16, 2018
Inspector: 'Naranjo, Ismael
Owner: MICHAEL G JOHNSON
Address: 930 NE 99 ST
Miami Shores, FL
Project: <NONE>
Contractor: T&S ROOFING SYSTEMS INC.
LOUIS TOLEDO
Permit Type: Roof
Inspection Type: Roofing Final
Work Classification: Flat
Phone Number: 3057727954
Parcel Number: 1132060143390
Phone Number: 3052652654
Building Department Comments
RE -ROOF FLAT,
Checklist Item
General Comments
Passed
Passed
False
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
Comments
Inspector Comments
October 15, 2018
For Inspections please call: 305-762-4949
Page 6 of 24
} Miami Shores Village
•
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
El BUILDING ❑ ELECTRIC ❑ ROOFING
RECEIVED
,JfL 08 2018,
BY:
F BC 20 f---
Master Permit No F �J ` 910
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL El PUBLIC WORKS ❑ CHANGE OF
CONTRACTOR
❑ CANCELLATION ❑ SHOP
DRAWINGS
JOB ADDRESS: 33 i\l"E 161
City: Miami Shores County: Miami Dade Zip:
rr
Folio/Parcel#: 1 � " 32. 0 g " V 11 3 3 is the Building Historically Designated: Yes
Occupancy Type: Load: Construction Type: Flood Zone: BFE:
OWNER: Name (Fee Simple Titleholder):
Address:
City: �I// i Cjlii I
eO61 CC er\-" \j,/\
((9c State: 1 t
Tenant/Lessee Name:
Email:
3135'
NO
FFE:
Phone#: -3 -' ? -3
Zip: 73 I -375
Phone#:
CONTRACTOR: Company Name: /
Address:
City:
Qualifier Name:
S
,y.. NW 51-(
(cc
State Certification or Registration #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
)7)0 Phone#: 34T 7V-, 7 Ey
State: C Zip: } 3/2 (/
LL,(� O` Phone#: J�%j` 7 7 f1I
cc (3 ZE U3 Z Certificate of Competency #:
Value of Work for this Permit: $ 2 'VC
Type of Work: ❑ Addition ❑ Alteration ❑
!COI - Tie/ -I-
Description of Work:
Square/Linear Footage of Work: ( a0
New ❑ Repair/Replace
❑ Demolition
Specify color of color thru tile:
Submittal Fee $ r33 ' dJ Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $ S�, —
TOTAL FEE NOW DUE $ 1-0•
/
• c,tt
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature (J'/ Signature
OWNER or AGENT
The foregoing instru nt wa acknowledged before me this
day of 20 IC( , by
C7�7 ► C ho is personally known to
CONTRACTOR
The foregoing instrument was acknowledged before me this
2 day of . ki1 ,20 (
VC'U S Ilti C , who is personally known to
, by
me or Who has produced as me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
***************
APPROVED BY
DANIEL Z
NotaryPubfc- Floridac`
Commission o .G 44769
My Comm. Expires Nov 3.2020
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
Plans Examiner
DANIE PE:EZ
Notary Public -�St. eoi Dorida
Commissio G 44769
My Comm. Expires Nov 3.2020
Zoning
(Revised02/24/2014)
Structural Review
Clerk
Page 1 of 1
Property Search Application - Miami -Dade County
ar..
OFFI
Summary Report
Property Information
Folio:
11-3206-014-3390
Property Address:
930 NE 99 ST
Miami Shores, FL 33138-2567
Owner
JESSICA J BERTHIN
MICHAEL G JOHNSON
Mailing Address
930 NE 99 ST
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1100 SGL FAMILY - 2301-2500 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
3/3/0
Floors
1
Living Units
1
Actual Area
2,954 Sq.Ft
Living Area
1,980 Sq.Ft
Adjusted Area
2,394 Sq.Ft
Lot Size
7,725 Sq.Ft
Year Built
1977
Assessment Information
Year
2018
2017
2016
Land Value
$231,797
$231,797
$201,109
Building Value
$180,508
$181,896
$183,285
XF Value
$973
$988
$1,003
Market Value
$413,278
$414,681
$385,397
Assessed Value
$413,278
$414,681
$379,937
Benefits Information
Benefit
Type
2018
2017
2016
Non -Homestead Cap
Assessment Reduction
$5,460
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
5-6 53 42
MIAMI SHORES SEC 3 PB 10-37
LOT 8 & E1/2 LOT 9 BLK 80
LOT SIZE 75 X 103
OR 17024-2842 1195 4
Generated On : 7/3/2018
Taxable Value Information
2018j 2017 2016
County
Exemption Value
$0
$0
$0
Taxable Value
$413,278
$414,681
$379,937
School Board
Exemption Value
$0
$0
$0
Taxable Value
$413,278
$414,681
$385,397
City
Exemption Value
$0
$0
$0
Taxable Value
$413,278
$414,681
$379,937
Regional
Exemption Value i $0! $0
$0
Taxable Value $413,278 $414,681
$379,937
Sales Information
Previous
Sale
Price
OR Book -
Pa 9e
Qualification Description
02/02/2018
$560,000
30859
0099
Qual by exam of deed
11/01/1995
$0
17024-
2842
Sales which are disqualified as a result
of examination of the deed
05/01/1982
$185,000
11455-
0110
Other disqualified
03/01/1978
$94,000
09966
1496
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
https://www.miamidade.gov/propertysearch/
7/3/2018
Section AB
Low slope roof area (ft.2)
"Delivering Excellence Every Day"
Master Permit No:
Contractor's Name:
Miami -Dade County HVHZ Electronic Roof Permit Form
Section A (General Information)
Process No:
T ANDS ROOFING
Job Address: 1930 ne 99 st
.................
O Low Slope
❑ Asphaltic Shingles
❑ Sprayed Polyurethane Foam
Roof Category
❑ Mechanically Fastened Tile
❑ Metal Panel/Shingles
❑ Other:
Roof Type
❑ New Roof 0 Re -Roofing ❑ Recovering ❑ Repair
Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No
Roof System Information
Steep Sloped area (ft.2) 0
400
•
• ....
• . •
� klortar/Adriesive Set Tile
•
Q NV:ood Shingle l/Shakes
•
•.... ....
. .
.. ..
• .
.. .
..•
..
• . .
•
❑ Maintenance .•
. . .
.
•
•
.
•
•
•
•
If yes, what type? ❑� Nattea),, -} LPGX
Section B (Roof Plan)
Total (ft.2)
f400
•
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Perimeter Width (a'):
Corner Size (a' x a'):
(:\GF
cs.0.\‘
3 0
APPROVED
ZONINGEDT
E3 LD-___.----
G DEPT
' , .,i7 .„Al I FE-nFFHAL
Al nr-lnCrn,^;IviuiiI=sAND rirGi1intIONS
Miami -Dade County HVHZ Electronic Roof Permit Form
Section C Page (Low Slope BUR Roof Systems)
Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box.
Roof System Manufacturer:
GAF
Product Approval (NOA ] 14-1030.01
NOA System Type:
1E
1Nind,Uplift Pressures'From,RAS 12a 6"FSealetl Galculatrons
(131) d Field,•'
42.8
psf
(P3) Corners:
(P2) , Perimeters:
108
psf
Maximum Design Pressure From NOA:
(P2) Perimeter (a') Size:
Roof Slope:
r .25 1
Parapet Walls:
ft.
El No El Yes
71.7
52 5
(P3) Corner Size:
psf
Roof Mean Height
psf
(x) a'
12
Parapet wall Height:
ft.
ft.
— 5/8" Plywood Deck—
LWIC Manufacturer:
Compressive
Strength:
psi
Support Spacing:
Existing Roof (For Recovers Only):
JFire Barrier:I
ft. o/c
Vapor Barrier:
Anchor Sheet:
Anchor Sheet Fastener/ Bonding Material:
Insulation Base Layer Size & Thickness:
Insulation Base Layer Fastener / Bonding Material:
Insulation Top Layer Size & Thickness:
Insulation Top Layer Fastener / Bonding Material:
Field:1
Number of Fasteners per Insulation Board:
Perimeter:
Corner:
Base Sheet(s)
#75 BASESHEET
Base Sheet Fastener / Bonding Material:.
1 1/4 RS NAILS
Ply Sheet(s):
(2)PLY IV
PIy Sheet Fastener / Bonding Material:
ASPHALT TYPE IV'....'
Ab
..
... .
• .
••
Top fit/Sheet:
.•
MINERAL SIUFFE CAPSIN T
• _ _....•
...•
Top PIy Sheet ig4teper / Bonding Material:
• • • • .
ASPH��'•'):YPE IV
Optignal Surf▪ acing: i
• • •
. '
•
• . .
...
Fastener Spacing for Base Sheet Attachment:
(P1)Field:
(P2) Perimeter:
(P3)Corner.
Lap Spacing
9
6
4
in. o/c
in. o/c
in. o/c
3
4
6
Row
Row(s)
Row(s)
Wood Nailer Type and Size:
9
6
4
in. o/c
in. o/c
in. o/c
Wood Nailer Fastener Type and Spacing:
- SELECT EDGE METAL MATERIAL --
- SELECT EDGE METAL WEIGHT OR THICKNESS —
— SELECT EDGE METAL HOOK STRIP SIZE --
Edge Metal Attachment:
— SELECT PARAPET WALL COPING MATERIAL —
-- SELECT COPING METAL SIZE OR THICKNESS —
— SELECT COPING METAL HOOK STRIP SIZE —
Parapet Coping Metal Attachment:
Reset Form
Print Form
Edge Nailabte Deck
Miami -Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day"
Illustrate Components Noted and Details as Applicable:
.
•
• • •
• • .
.
• • • •
• •
• • • •
• • • .
• •
• •
.
Top Ply
!Warplies \
\
Base Sheet \ \ I
\
5.
Roof Deck
(
Drip Metal
• • • • *
• • • •
• •
• • • •
• • • •
• •
• • • •
• • •
• • • •
• •
•
.
.
11-2-11-11L•-•__
• ' .
.
. .
• . . .
• • .
• • •
• •
Roof Mean Height:
Drip Metal:
•
• • .
• • •
ft• •
•
3X3 GALV 26 GA
Surfacing:
Top P1y:
MINERAL SURFACE CAPSHEET
Interplies:
(2 ) PLY IV
Base Sheet:
13175 BASE SHEET
Deck Type:
15/8 CDX PLYWOOD
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of SecWon R4402
govern the minimum requirements and standards of the industry for roofing system in:tallfigns. Addttfortally, the •
following items should be addressed as part of the agreement between the owner ant tfis cofltractot`7he owner's ••
initial in the designated space indicates that the item has been explained. • • •
.
.••• •...
••
•
•
2. &3Renailing wood decks: When replacing roofing, the existing vroV%f deqrngy have toP • • • •
nailed in accordance with the current provisions of Section R4403. (The'mof deck is usitaliy
concealed prior to removing the existing roof system). . • • • •
•
. • •
. • .
. •
4. ICJ''/ Exposed Ceiling: Exposed, open beam ceilings are where the underside of tPiordofdecking •
can e viewed from below. The owner may wish to maintain the architectural appearance; therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and R4413.
5J3°II8
Owner/ nt's Signature Date Contra Signature Date
i
13a Nit 91 91'1W, f (KM If f,33(ft
Property Address
Revised on 7/9/2009 LD;07/01/2015;
Permit Number
iami Shores Viii
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTINGSIJE•
s •
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES' •. • •; •;; • •,
PERSUANT TO SECTION 553.844 F.S.
•
•
••
.•
•
• •
•••• •••• • •
• • •
To: Miami Shores Village Building Department • • • • . • • • • •
Hate: • • •
10050 NE 2nd Ave •••••• ••••••
Miami Shores, FI 33138 ••
•• • • •
Re: Owner's Name: ,)eeyn,) cfct {�, \r\ kA :• •• ° • •
• •
Property Address: C w - i j '51 • • • • • •
Roofing Permit Number:
Dear Building Official:
y7E;4.5.-IC:c7.‘(� fi f certify that i am not required to retrofit the roof to wall connections of my
building because:
❑ The just valuation for the structure for purpose of ad valorem taxation is Tess than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
Signature
J 51 tA 6e r-jFt uJ
Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn, deposes and says that he/sh,e is the owner for the above property mentioned.
Sworn to and subscribed before me this
Notary Public, Sate of Florida at Large
day
sn of
F.
DANIEL PEREZ
Notary Fublic- State of Florida
Commission GG 44769
sFcc:� ?c My Comm. Expires Nov 3, 2020
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for th 'Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF
1 Campus Drive
Parsippany, NJ 07054
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
www.miamidade.gov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
....
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Caunty.Produci • • • • •
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dadetoanty) • • • .
reserve the right to have this product or material tested for quality assurance purposes. If'th l5roduct or
material fails to perform in the accepted manner, the manufacturer will incur the expens"e'df s'iich testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material withintjipir, •
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Milrpi-j hde County .
Product Control Section that this product or material fails to meet the requirements of tbr..dpplicable' .. • •
building code. • •
. • •
This product is approved as described herein, and has been designed to comply with the Florida Building bode •
including the High Velocity Hurricane Zone of the Florida Building Code. ' • • • • • .. • •
• • •
••• •
DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks.
.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31.
The submitted documentation was reviewed by Jorge L. Acebo.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 1 of 31
ROOFING SYSTEM APPROVAL
Category:
Sub -Category:
Material:
Deck Type:
Maximum Design
TRADE NAMES
Product
GAFGLAS® Ply 4
Tri-Ply® Ply 4
GAFGLAS®
F1exPly 6
GAFGLAS®#75
Base Sheet
Tri-Ply®#75 Base
Sheet
GAFGLAS®#80
Ultima'Base Sheet
GAFGLAS®
Stratavent®
Perforated Venting
Base Sheet
GAFGLAS®
Stratavent® Nailable
Venting Base Sheet
Ruberoid® 20
Smooth
Ruberoid® Mop
Smooth
Ruberoid®.Mop
Smooth 1.5
Ruberoid® Mop
Plus Smooth
Ruberoid® HW 25
Smooth
Pressure:
Roofing
BUR
Fiberglass
Wood
-97.5 psf.
OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
MIAMI•DADE COUNTY
APPROVED
Dimensions
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
Test
Specification
ASTM D2178
ASTM D2178
ASTM D2178
ASTM D4601
ASTM D4601
ASTM D4601
ASTM D4897
Product
Description
Smooth surfaced asphaltic ply sheet reinforced
with fiberglass mat.
Smooth surfaced asphaltic ply sheet reirorced
with fiberglass mat.
. . .
.. . ... .
..
Smooth surfaced asphalticIJ1 ti et reinforce$
•
with fiberglass mat.
.... ....
•
Smooth asphaltic base or baWpiy sheet r'etiforced
with fiberglass mat. . . . • •
..• .. •••••
Smooth asphaltic base or bpe/ sheet reinforced
with fiberglass mat. '
•
. • .
Smooth asphaltic base or basee/ply'sheetitiV15=ced
with fiberglass mat.
Smooth surfaced asphaltic perforated venting base
sheet reinforced with fiberglass mat.
ASTM D4897 Smooth surfaced asphaltic nailable venting base
sheet reinforced with fiberglass mat. Bottom side
surfaced with granules.
ASTM D6163 SBS polymer -modified asphalt base or
anchor sheet reinforced with a fiberglass mat.
ASTM D6164 Smooth surfaced mop applied SBS base or
anchor sheet reinforced with a polyester mat.
ASTM D6164 Smooth surfaced mop applied SBS base or anchor
sheet reinforced with a polyester mat.
ASTM D6164 Smooth surfaced mop applied SBS base or
anchor sheet reinforced with a polyester mat.
ASTM D6163 Smooth surfaced torch applied SBS base or anchor
sheet reinforced with a fiberglass mat.
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 2 of 31
•
•
•
•
•
• •
•
•
•
•
•
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Ruberoid® HW
Smooth
GAFGLAS®
Mineral Surfaced
Cap Sheet
Tri-Ply® BUR.
Granule Cap Sheet
GAFGLAS®
EnergyCap'T'
Mineral Surfaced
Cap Sheet
Topcoat® Surface
Seal SB
Topcoat®
Membrane
Topcoat® MB Plus
Topcoat® FireOut'
Fire Barrier Coating
VersaShield®Fire-
Resistant Roof
Deck Protection
VersaShield® Solo'
Fire -Resistant Slip
Sheet
Topcoat®
FlexSear
Dimensions
39.37" (1 meter)
wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
39.37" (1 meter)
Wide
5 or 55 gallons
1, 5 or 55 gallons
5 or 55 gallons
5 or 55 gallons
12" x 100' rolls
42" roll wide, 100
ft.
MIAMI•DADE COUNTY
APPROVED
1, 5 gallons or
1 qt. tube
Test
Specification
ASTM D6164
ASTM D3909
ASTM D3909
ASTM D3909
ASTM D6083
ASTM D6083
Proprietary
Proprietary
ASTM D226
ASTM D146,
D828, D4869,
D6757
TAS 139
Product
Description
Smooth surfaced torch applied SBS base or anchor
sheet reinforced with a polyester mat.
Granule surfaced asphaltic cap sheet reinforced
with fiberglass mat.
Granule surfaced asphaltic cap sheet reinforced
with fiberglass mat.
Granule surfaced asphaltic cap sheet reinforced
with fiberglass mat. Cap sheet is factor coated
with TOPCOAT® EnergyCote'T' Elasto •
Coating.
• • .
..• . •.• •
• •
..
Solvent -based thermoplastic r*bber •
sealant designed to protect aactiestore agedjoof
surfaces and to increase roof reff7.8etivity.. • • •'
Water -based elastomeric coating •
• . .
.••
..
•
. .
Water based, low VOC primer designedtvblotk
asphalt bleed -through. • • • • ..
•. .
Low VOC, water based fire barrier coating •
Non -asphaltic, fiberglass reinforced underlayment
and/or fire barrier
Non -asphaltic, fire resistant fiberglass
underlayment
Solvent -based elastomeric sealant.
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 3 of 31
APPROVED INSULATIONS:
Product Name
EnergyGuardTM Polyiso
Insulation
TABLE 2
Product Description
Polyisocyanurate foam insulation
Manufacturer
(With Current NOA)
GAF'
EnergyGuardTM Tapered Polyisocyanurate foam insulation GAF
Polyiso Insulation
EnergyGuard' Ultra Polyiso Glass -faced polyisocyanurate foam insulation GAF
Insulation
EnergyGuard'M RA Polyiso
Insulation
EnergyGuard' RA Composite
Polyiso Insulation
EnergyGuardTM RH Polyiso
Insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation with high
density fiberboard or permalite
Polyisocyanurate foam insulation
GAF
GAF .••••
. . .
GAF ••
•
••GAF •....
•
EnergyGuardTM RH Tapered Polyisocyanurate foam insulation •
Polyiso Insulation
EnergyGuard' RN Polyiso Polyisocyanurate foam insulation
Insulation
EnergyGuard' Perlite Roof Perlite insulation board
Insulation
....
.
•
. . .
.. .. .. ..
GAF •
. . .
•
. .
•
. •
• • 'AF
• . •
..•
EnergyGnardTM Perlite Recover Perlite recover board GAF
Board
Securock® Gypsum -Fiber Roof Gypsum board United States Gypsum Corp.
Board
Securock® Glass -Mat Roof Glass faced gypsum board United States Gypsum Corp.
Board
Structodek® High Density Fiber High density fiberboard Blue Ridge Fiberboard, Inc.
Board Roof Insulation
DensDeck® Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC
DensDeck® Roof Board Gypsum board Georgia-Pacific Gypsum LLC
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 4 of 31
APPROVED FASTENERS:
Fastener
Number
Product
Name
1. Drill-Tec'T` #12 Fastener
2. Drill-Tece" #14 Fastener
3. Drill-Tec' ASAP 3S
4. Drill-Tec" 3" Steel Plate
5. Drill -Teo' 3" Standard Steel
Plate
6. Drill-Teoe' AccuTrac® Flat
Plate
7. Drill-Tec'"' AccuTrac®
Recessed Plate
8. Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
MIAMIDADE COUNTY
APPROVED
TABLE 3
Product
Description
Phillips head, modified
buttress thread, pinch point,
carbon steel fastener for use
in steel or wood decks. With
CR-10 coating. Available
with a pinch point or drill
point.
Truss head, self -drilling,
pinch point, high thread
fastener for use in steel, wood
or concrete decks.
Drill-Tec""` #12 Fastener with
Drill-Tec" 3" Standard Steel
Plate.
Round Galvalumee steel
stress plate with reinforcing
ribs and recessed for use with
Drill -Teem fasteners.
Galvalume® coated steel
stress plate for use with
approved Drill-Tec°
fasteners.
A2-SS alnmini7ed steel plate
for use with Drill-Tec"''
fasteners.
Galvalume® steel plate with
recess for use with Drill-
TecT"' fasteners.
Round Galvalume® plated
steel stress plate with
reinforcing ribs for use with
Drill-Tec'" fasteners.
Manufacturer
Dimensions (With Current NOA)
#12 x 8" max.
length, #3
Phillips head.
#14 x 16"
max. length,
#3 Phillips
head. •
•• •
See •
components
••••
• •
3" Round GAF .
GAF
GAF
••••
• •
• • • •
• • •
'AF••
•
•
• •
•. . •
• . .
•• •
• • •
3" Round • • • • • GAF.
• . .
•••.
• .
•.••
• • •
•• ••
•
••
3" square;
.017" thick
3" square;
.017" thick
3" Round
•. •
GAF
GAF
GAF
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 5 of 31 •
•
•
•
EVIDENCE SUBMITTED:
Test Agency
Factory Mutual Research Corp.
UL LLC
PRI Construction Materials
Technologies, LLC
Test Identifier
3014547
3029832
3033135
3034312
3036980
3038278 "
3040738
3041769
3042887
3042905
3046081
3047636
OD0A8.AM
OD1A8.AM
0Y9Q5.AM
1B9A8.AM
2B8A4.AM
3B9Q1.AM
3D4Q2.AM
797-03221-267
797-03825-267
797-10228-267
R1306
GAF-012-02-02
GAF-020-02-01
GAF-082-02-01
GAF-084-02-01
GAF-122-02-01
GAF-270-02-02
GAF-276-02-01Rev
GAF-276-02-02
GAF-306-02-01
GAF-314-02-01
GAF-315-02-01
GAF-3 69-02-01
GAF-417-02-01
GAF-464-02-01
GAF-464-02-01
GAF-499-02-01
GAF-500-02-01
GAF-549-02-01
GAF-549-02-02
GAF-559-02-01
Description
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
UL 790
• . •
•. •
•
•.. •
• •
....
.. .•
. .
ASTM D4977 .
ASTM D4977
ASTM D6083
ASTM D6083
TAS 139
ASTM D226
ASTM D6083
ASTM D226
ASTM E96
ASTM D2178
ASTM D2178
ASTM C1289
ASTM C1289
ASTM C1289
ASTM C1289
ASTM D6083
ASTM D6083
TAS 114
TAS 114
TAS 117(B)
. .
•
•
•
•
Date
05/22/03
05/11/07
11/24/08
04/09/09
08/14/09
11/18/11
11/16/10
05/26/11
11/14/11
01/10/12
02/13/13
08/08/13
07/09/99
07/29/94
04/01/98
.'69)t4/97
• •O'3%2/97
0?/j/98
05/30/97
•09/c7/07 •
•'03h21/08
•'O1,/23/15.
04/04/17
:'PP/OS/01 •
• 02/01/02 •
•
'0►5M7/06
05/09/06
05/07/06
11/15/10
12/16/10
11/15/10
07/07/11
08/23/11
08/23/11
10/22/12
05/28/13
10/22/12
02/06/14
03/12/14
03/12/14
08/08/14
08/08/14
09/30/14
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 6 of 31
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency
PRI Construction Materials
Technologies, LLC
IRT of S. Fl.
Trinity I ERD
Atlantic & Caribbean Roof
Consultants, LLC
MIAMI•DADE COUNTY
APPROVED
Test Identifier
GAF-559-02-04
GAF-559-02-05
GAF-559-02-06
GAF-559-02-07
GAF-559-02-08
GAF-559-02-09
GAF-559-02-11
GAF-559-02-12
GAF-559-02-13
GAF-559-02-14
GAF-559-02-15
GAF-559-02-16
GAF-559-02-18
GAF-559-02-19
02-005
02-014
C8500SC.11.07
G30250.02.10-3-R2
G31360.03.10
G33470.01.11
G34140.04.11-2
G34140.04.11-4-R2
G34140.04.11-5-R3
G36780.07.11-R1
G40630.01.14-1
G40630.01.14-2A
G40630.01.14-2A-1-R1
G43610.01.14
G6850.08.07-1
SC6870.08.14-R1
Description Date
ASTM D 1876 10/01/14
ASTM D 1876 10/15/14
TAS 114(H) 10/02/14
ASTM D 903 10/02/14
ASTM D 903 10/02/14
ASTM D 903 10/02/14
TAS 114 10/14/14
TAS 114 10/14/14
TAS 114 10/15/14
TAS 114 10/15/14
TAS 114 10/15/14
TAS 114 10/15/14
TAS 114 10/15/14
TAS 114 04/16/15
TAS 114 4,Q1418/02
TAS 114 . . •.03622./02
. . .
•
•
TAS 117 •• ••11430/07 ••
ASTM D3909 • 06/03/15
ASTM D6164 .... .Q. I31/10 •
ASTMD6164•••••• }},05/11
ASTM D6163 . . •04/Z/11
ASTM D6401 • • • • •06it 4/15
ASTM D4897 • •• •• 0�/04/15
•4470-TAS 114, • • 03/18/11
ASTM D6163 •.. • •.O1/D6/14 . •
ASTM D6164 • At/0,/14
ASTM D6164 04/10/14
ASTM D3909 01/22/14
ASTM D3909 08/13/07
ASTM D3909 09/04/14
.•
11-053 TAS 114 08/12/11
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 7 of 31
•
Membrane Type:
Deck Type 1:
Deck Description:
System Type E(1):
BUR
Wood, Non -insulated
19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and
intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max.
Anchor sheet mechanically attached to roof deck.
All General and System Limitations shall apply.
Fire Barrier:
(optional)
Base sheet:
Fastening
Option #1:
Fastening
Option #2:
Ply Sheet:
Cap Shee j
Surfacing:
Maximum Design
Pressure:
• • .... •1/••I•
(Maximum Design Pressure —52.5 psf See General Limitation #7) • • • • • ' •
... . ..
GAFGLAS® #80 Ultima Base Sheet, Ruberoid Smooth oreid®Mop Smooth •
attached to deck with approved 11/4" annular ring shank nails and'ift 4ed 3"Steel late ara •
.fastener spacing of 9" o.c. at the 4" lap and in two rows staggeredwith a fastener spacing o1 • •.
9" o.c. in the center of the membrane. •
Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck
Protection, VersaShield® Solo" Fire -Resistant Slip Sheet installed per manufacturer's
installation instructions.
GAFGLAS® #80 Ultima' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid®
20 Smooth, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS Heat -Weld' 25 base
sheet mechanically fastened to deck as described below;
GAFGLAS® Flex Ply' 6, GAFGLAS #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of-
the above anchor sheets attached to deck with approved annular ring shank nails and tin
caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9"•e epin the (
field.
•
. . .
E.One or more plies of GAFGLAS® Ply 4)Tri-Ply® Ply 4 or GAFGLASf#80131 xa i3ase •
Sheet adhered in a full mopping of approved asphalt applied wit the,EVT r i gq, and at p.
rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. • . •
(Optional One ply of GAFGLAS® Mineral Surfaced Cap Sheet)rri-Ply® BUR Granule
Cap Sheet or GAY'EnergyCap Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
installed per manufacturer's installation instructions.
Optional on granular surfaced membranes; required for smooth membranes. Chosen
components must be applied according to manufacturer's application instructions.
All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
Topcoat® Membrane applied at 0.5 to 0.75 gal./sq.
3. Fiber Aluminum Roof Coating.
MIAMIDADE COUNTY
APPROVED
. . • • •
•
(Maximum Design Pressure —60 psf. See General Limitation #.7.) ..
See Fastening Options
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 25 of 31
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply` 6 when used as a mechanically fastened
base or anchor sheet.
2. Minimum'/4" DensDeck' Roof Board or 'A" Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows) one at
each sidelap and one down the center of the sheet allowing a continuous area of ventil ion. • Encirctipm,f4the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow crdss.deiZtilation..Asphalt •
•
application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attaehed systems seal; be
limited to a maximum design pressure of -45 psf. •
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force.altalue of.27? ilaf., as ' •
tested incompliance with Testing Application Standard TAS 105. If the fastener value; as Meld-testeci,•are below • •
275 lbf. insulation attachment shall not be acceptable. • •
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachmvZi:i<ased on a.minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should thee.: .
fastener resistance be less than that required, as determined by the Building Official, a ievi •erl fastener spacing, • •
prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or ettiSt@red • '
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When. this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofmg Application Standard RAS 11.1 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 31 of 31
The 'hoof deck;mayi first be coveted with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS® Stratavent® Nailable Venting Base
e, 5heet'4.oi;''GQFGLAS® Stratavent® Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing
. aipTia it arid nailable base sheets are to be mechanically fastened. granule side down.
°As.anoption Type.G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® 480 UltimaTM
PBase ly 4"
or e Tri Ply® Ply 4" or GAFGLAS® Flex Ply 6"eor'"Trng BPIy® Ultrase a -Flexible ex ble Ply 6) may be °) as the nailed base ply in thted for Type GI asphalt e follss owing r systems. sheet GAFGLAS®
Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened.
Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened.
"GAFGLAS® Flashing" or "RUBEROID®" may be used for flashing in any of the Class A, B or C systems listed below.
When "perlite" is referenced, this includes any UL Classified perlite insulation.
Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems fisted.
Structural cement fiber building units are considered suitable to be included as a deck.in the following Class A, B or C systems listed over C-15/32
or NC.
The use of gypsum board under any of the following Cass A, B or C systems does not adversely affect the rating. The use of 1/2-in. minimum
thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks.
The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/rosin
paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems.
Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt".
"GAFGLAS® #80 Ultima.'" Base Sheet" may be used in any of the following systems.
"GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications.
Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United CoatingsTM FireShield MB
Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2.
Class A, B and C
Hot roofing asphalt, for use with glass felts or modified bitumen membranes. .
"RUBEROID® Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROID® Mbp" SBS roofing
Classification.
Class A
••••
• •
• • ••••
• • •
•• •' ••• •
rnerr:br-anes in any al3plitable
•
•
� •
• •
•••• •••• • •
• • • •
•••• ••••
• •
1. Deck: C-15/32 Incline: 3 • •
• • • • •
•• •• •• ••
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum L`c;gerysDeck® Roa fboard" or • •
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in, thick United -States GypsumCo. •
"SECUROCK® Roof Board° (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX).
Vapor Barrier (Optional): — One or more plies "GAF® SA Vapor Retarder" self -adhered • ; • • . • • •
Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane•or pai'Iite/poIyisoc anurate. •
composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. ••. • .
•
Ply Sheet: — Three or more plies Type Gi "GAFGLAS® Ply 4" or 'Tr -Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tr -Ply® Ultra -Flexible Ply
6", fully adhered with hoot roofing asphalt.
Surfacing: — Gravel.
2. Deck: C-15/32 Incline: 2
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick.United States Gypsum Co.
"SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX).
Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate
composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type Gi "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Fiex Ply 6" or "Tr -Ply® Ultra -Flexible Ply
6", fully adhered with hot roofing asphalt.
Cap Sheet — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapm
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
3. Deck: NC Incline: 2
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co.
"SECUROCK® Roof Board".(Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX).
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, 2-in. maximum.
Ply Sheet: — Two or more plies Type Gi "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply
6", fully adhered with hotroofing•asphalt.
Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
Incline:1
Slip Sheet (Optional): — Red rosin paper, nailed to deck.
ittp://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=TGFU.R1306&ccnshorttitie=Roofing+Systems&objid=1074351... 2/48
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
'O"t40 ins2gyBonstastening,,Systeri4gLailation adhesive.
`. p •b .c'e •8heet• — One pl�Ty_pe G2 GAFGLAS® #75 Base Sheet'•4 or 'Tri-Ply® #75 Base Sheet' or 'GAFGLAS® #80 UltimaTM Base Sheet"
or i AFGLAS®'Strataven LVa.ilabl.e�lenl:Gna_easCsheet"� mechanically fastened.
• [PIy sheet= Ore plies eo Gl AFGLAS® Pii 4'.L for "Tri-Ply® Ply 4" or GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply
fullyaci er_'etwitb hot roofing asphalt.
"Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced CapSheet;'i'or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM
Mineral -Surfaced Cap Sheet", fully adheres wit hot roofing asphalt.
Coating (Optional): — "United Coatings."' TOPCOAT® EnergyCoteTM Roof Coating" or "TOPCOAT® MB Plus Coating" or "United
CoatingsTM Roof Mate MB Plus Coating" applied at a rate of 2-gal./100-ft.2.
5. Deck: NC Incline: 3
Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM Base Sheet"
or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS®
Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully
adhered with hot roofing asphalt.
Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply
6", fully adhered with hot roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT""
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
6. Deck: C-15/32 Incline: 2
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co.
"SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX).
Insulation: — One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or
perlite/urethane composite or phenolic, 1-in. minimum (offset a minimum of 6-in. from plywood deck joints).
Base Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6" or "Tri-Ply® Ultra -Flexible
Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima.Tt" Base Sheet" or Type G3
"GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing
asphalt.
Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-Ply® APP Smooth" or "RUBEROID® Torch Granule" on. • •
"RUBEROID® Torch 180" or "Tri-Ply® APP Granule", torch applied or "RUBERDID® Mop Smooth" or "RUBEIOID( Mop Snntaptly YS" or
"RUBERDID® Mop Plus Smooth" or "RUBERDID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SBS Granule" fu!Ily�edhered with hot •
•• • ••• • •
roofing asphalt. • • •
Cap Sheet — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or 'Tri-Ply® BUR Granule Cap Sheet" or ' k?f lS® EnergyCaQ'y
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • • •
7. Deck: C-15/32 Incline: 2
•••• • • • • • •
• • • •
• • • • ••••
• •
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "Denslac%NRoofbaerd'Lor:
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick United ShtLs rpsum Co"• • •
"SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • • •
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or • • •
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite Qr phenolic, ant tJTitler}2ss. • •
Base Sheet: — Two or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or 'CAMAS® #80 Uitimam
Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforatedtentig Baso Met; • •
"GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type 65 •
"GAFGLAS® Mineral Surfaced Cap Sheet" or 'Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing
asphalt.
Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6 or 'Tri-Ply® Ultra -
Flexible Ply 6", fully adhered with hot roofing asphalt.
Membrane: — One or more plies "RUBEROID® Torch Smooth" or 'Tri-Ply® APP Smooth" or "RUBERDID® Torch Granule" or
"RUBEROID® Torch 180" or 'Tri-Ply® APP Granule", torch applied or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or
"RUBERDID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SOS Granule" fully adhered with hot
roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT"'
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
8. Deck: NC Incline: 2
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'm Roofboard" or minimum 1/4-in. thick United States Gypsum Co.
"SECUROCK® Roof Board" (Type FRX G) or "SECUROCK® Glass -Mat Roof Board". (Type SGMRX).
Insulation (Optional): — Perlite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened, any thickness.
Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM
Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or
"GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically
fastened or fully adhered with hot roofing asphalt.
PIy Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Piy
6", fully adhered with hot roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet', fully adhered with hot roofing
asphalt.
Coating: — "United CoatingsT"" FireShield MB Roof Coating' applied at a rate of 2-1/2 to 3-gal./100-ft.2.
3. Deck: C-15/32 Incline: 1
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick United States Gypsum Co.
"SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX).
//database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnshorttitle=RoofingtSystems&objid=1074351... 3/48