Loading...
RF-18-1810Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Issue Date: 7/3/2018 Permit NO. RF-7-18-1810 Permit Type: Roof Work Classification: Flat Permit Status: APPROVED Expiration: 12/30/2018 Parcel Number Applicant 930 NE 99 Street Miami Shores, FL 1132060143390 Block: Lot: JESSICA J BERTHIN Owner Information Address Phone Cell MICHAEL G JOHNSON 930 NE 99 Street MIAMI SHORES FL 33138- (305)772-7954 930 NE 99 Street MIAMI SHORES FL 33138- Contractor(s) T&S ROOFING SYSTEMS INC. Phone 305/265-2654 CeII Phone Valuation: Total Sq Feet: $ 2,800.00 400 Type of Work: Re Roof Additional Info: RE -ROOF FLAT. Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Amount $500.00 $1.80 $3.75 $2.50 $0.60 $250.00 $9.00 $2.40 Total: $770.05 Pay Date Pay Type Invoice # RF-7-18-68122 07/03/2018 Check #: 34802 $ 770.05 $ 0.00 Bond #: 3817 Amt Paid Amt Due Available Inspections: Inspection Type: Tin Cap Final Roof Roof in Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the oreg g information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I author e f e above -named contractor to do the work stated. Authorized Signature: Owner / A licant / Contractor / Agent July 03, 2018 Date Building Department Copy July 03, 2018 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number: INSP-000659-2018 Permit Number: RF-7-18-1810 Scheduled Inspection Date: October 16, 2018 Inspector: 'Naranjo, Ismael Owner: MICHAEL G JOHNSON Address: 930 NE 99 ST Miami Shores, FL Project: <NONE> Contractor: T&S ROOFING SYSTEMS INC. LOUIS TOLEDO Permit Type: Roof Inspection Type: Roofing Final Work Classification: Flat Phone Number: 3057727954 Parcel Number: 1132060143390 Phone Number: 3052652654 Building Department Comments RE -ROOF FLAT, Checklist Item General Comments Passed Passed False Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Comments Inspector Comments October 15, 2018 For Inspections please call: 305-762-4949 Page 6 of 24 } Miami Shores Village • Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION El BUILDING ❑ ELECTRIC ❑ ROOFING RECEIVED ,JfL 08 2018, BY: F BC 20 f--- Master Permit No F �J ` 910 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL El PUBLIC WORKS ❑ CHANGE OF CONTRACTOR ❑ CANCELLATION ❑ SHOP DRAWINGS JOB ADDRESS: 33 i\l"E 161 City: Miami Shores County: Miami Dade Zip: rr Folio/Parcel#: 1 � " 32. 0 g " V 11 3 3 is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): Address: City: �I// i Cjlii I eO61 CC er\-" \j,/\ ((9c State: 1 t Tenant/Lessee Name: Email: 3135' NO FFE: Phone#: -3 -' ? -3 Zip: 73 I -375 Phone#: CONTRACTOR: Company Name: / Address: City: Qualifier Name: S ,y.. NW 51-( (cc State Certification or Registration #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: )7)0 Phone#: 34T 7V-, 7 Ey State: C Zip: } 3/2 (/ LL,(� O` Phone#: J�%j` 7 7 f1I cc (3 ZE U3 Z Certificate of Competency #: Value of Work for this Permit: $ 2 'VC Type of Work: ❑ Addition ❑ Alteration ❑ !COI - Tie/ -I- Description of Work: Square/Linear Footage of Work: ( a0 New ❑ Repair/Replace ❑ Demolition Specify color of color thru tile: Submittal Fee $ r33 ' dJ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ S�, — TOTAL FEE NOW DUE $ 1-0• / • c,tt (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature (J'/ Signature OWNER or AGENT The foregoing instru nt wa acknowledged before me this day of 20 IC( , by C7�7 ► C ho is personally known to CONTRACTOR The foregoing instrument was acknowledged before me this 2 day of . ki1 ,20 ( VC'U S Ilti C , who is personally known to , by me or Who has produced as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: *************** APPROVED BY DANIEL Z NotaryPubfc- Floridac` Commission o .G 44769 My Comm. Expires Nov 3.2020 identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Plans Examiner DANIE PE:EZ Notary Public -�St. eoi Dorida Commissio G 44769 My Comm. Expires Nov 3.2020 Zoning (Revised02/24/2014) Structural Review Clerk Page 1 of 1 Property Search Application - Miami -Dade County ar.. OFFI Summary Report Property Information Folio: 11-3206-014-3390 Property Address: 930 NE 99 ST Miami Shores, FL 33138-2567 Owner JESSICA J BERTHIN MICHAEL G JOHNSON Mailing Address 930 NE 99 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/3/0 Floors 1 Living Units 1 Actual Area 2,954 Sq.Ft Living Area 1,980 Sq.Ft Adjusted Area 2,394 Sq.Ft Lot Size 7,725 Sq.Ft Year Built 1977 Assessment Information Year 2018 2017 2016 Land Value $231,797 $231,797 $201,109 Building Value $180,508 $181,896 $183,285 XF Value $973 $988 $1,003 Market Value $413,278 $414,681 $385,397 Assessed Value $413,278 $414,681 $379,937 Benefits Information Benefit Type 2018 2017 2016 Non -Homestead Cap Assessment Reduction $5,460 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 5-6 53 42 MIAMI SHORES SEC 3 PB 10-37 LOT 8 & E1/2 LOT 9 BLK 80 LOT SIZE 75 X 103 OR 17024-2842 1195 4 Generated On : 7/3/2018 Taxable Value Information 2018j 2017 2016 County Exemption Value $0 $0 $0 Taxable Value $413,278 $414,681 $379,937 School Board Exemption Value $0 $0 $0 Taxable Value $413,278 $414,681 $385,397 City Exemption Value $0 $0 $0 Taxable Value $413,278 $414,681 $379,937 Regional Exemption Value i $0! $0 $0 Taxable Value $413,278 $414,681 $379,937 Sales Information Previous Sale Price OR Book - Pa 9e Qualification Description 02/02/2018 $560,000 30859 0099 Qual by exam of deed 11/01/1995 $0 17024- 2842 Sales which are disqualified as a result of examination of the deed 05/01/1982 $185,000 11455- 0110 Other disqualified 03/01/1978 $94,000 09966 1496 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/propertysearch/ 7/3/2018 Section AB Low slope roof area (ft.2) "Delivering Excellence Every Day" Master Permit No: Contractor's Name: Miami -Dade County HVHZ Electronic Roof Permit Form Section A (General Information) Process No: T ANDS ROOFING Job Address: 1930 ne 99 st ................. O Low Slope ❑ Asphaltic Shingles ❑ Sprayed Polyurethane Foam Roof Category ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Other: Roof Type ❑ New Roof 0 Re -Roofing ❑ Recovering ❑ Repair Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No Roof System Information Steep Sloped area (ft.2) 0 400 • • .... • . • � klortar/Adriesive Set Tile • Q NV:ood Shingle l/Shakes • •.... .... . . .. .. • . .. . ..• .. • . . • ❑ Maintenance .• . . . . • • . • • • • If yes, what type? ❑� Nattea),, -} LPGX Section B (Roof Plan) Total (ft.2) f400 • Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Corner Size (a' x a'): (:\GF cs.0.\‘ 3 0 APPROVED ZONINGEDT E3 LD-___.---- G DEPT ' , .,i7 .„Al I FE-nFFHAL Al nr-lnCrn,^;IviuiiI=sAND rirGi1intIONS Miami -Dade County HVHZ Electronic Roof Permit Form Section C Page (Low Slope BUR Roof Systems) Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof System Manufacturer: GAF Product Approval (NOA ] 14-1030.01 NOA System Type: 1E 1Nind,Uplift Pressures'From,RAS 12a 6"FSealetl Galculatrons (131) d Field,•' 42.8 psf (P3) Corners: (P2) , Perimeters: 108 psf Maximum Design Pressure From NOA: (P2) Perimeter (a') Size: Roof Slope: r .25 1 Parapet Walls: ft. El No El Yes 71.7 52 5 (P3) Corner Size: psf Roof Mean Height psf (x) a' 12 Parapet wall Height: ft. ft. — 5/8" Plywood Deck— LWIC Manufacturer: Compressive Strength: psi Support Spacing: Existing Roof (For Recovers Only): JFire Barrier:I ft. o/c Vapor Barrier: Anchor Sheet: Anchor Sheet Fastener/ Bonding Material: Insulation Base Layer Size & Thickness: Insulation Base Layer Fastener / Bonding Material: Insulation Top Layer Size & Thickness: Insulation Top Layer Fastener / Bonding Material: Field:1 Number of Fasteners per Insulation Board: Perimeter: Corner: Base Sheet(s) #75 BASESHEET Base Sheet Fastener / Bonding Material:. 1 1/4 RS NAILS Ply Sheet(s): (2)PLY IV PIy Sheet Fastener / Bonding Material: ASPHALT TYPE IV'....' Ab .. ... . • . •• Top fit/Sheet: .• MINERAL SIUFFE CAPSIN T • _ _....• ...• Top PIy Sheet ig4teper / Bonding Material: • • • • . ASPH��'•'):YPE IV Optignal Surf▪ acing: i • • • . ' • • . . ... Fastener Spacing for Base Sheet Attachment: (P1)Field: (P2) Perimeter: (P3)Corner. Lap Spacing 9 6 4 in. o/c in. o/c in. o/c 3 4 6 Row Row(s) Row(s) Wood Nailer Type and Size: 9 6 4 in. o/c in. o/c in. o/c Wood Nailer Fastener Type and Spacing: - SELECT EDGE METAL MATERIAL -- - SELECT EDGE METAL WEIGHT OR THICKNESS — — SELECT EDGE METAL HOOK STRIP SIZE -- Edge Metal Attachment: — SELECT PARAPET WALL COPING MATERIAL — -- SELECT COPING METAL SIZE OR THICKNESS — — SELECT COPING METAL HOOK STRIP SIZE — Parapet Coping Metal Attachment: Reset Form Print Form Edge Nailabte Deck Miami -Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: . • • • • • • . . • • • • • • • • • • • • • . • • • • . Top Ply !Warplies \ \ Base Sheet \ \ I \ 5. Roof Deck ( Drip Metal • • • • * • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • . . 11-2-11-11L•-•__ • ' . . . . • . . . • • . • • • • • Roof Mean Height: Drip Metal: • • • . • • • ft• • • 3X3 GALV 26 GA Surfacing: Top P1y: MINERAL SURFACE CAPSHEET Interplies: (2 ) PLY IV Base Sheet: 13175 BASE SHEET Deck Type: 15/8 CDX PLYWOOD SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of SecWon R4402 govern the minimum requirements and standards of the industry for roofing system in:tallfigns. Addttfortally, the • following items should be addressed as part of the agreement between the owner ant tfis cofltractot`7he owner's •• initial in the designated space indicates that the item has been explained. • • • . .••• •... •• • • 2. &3Renailing wood decks: When replacing roofing, the existing vroV%f deqrngy have toP • • • • nailed in accordance with the current provisions of Section R4403. (The'mof deck is usitaliy concealed prior to removing the existing roof system). . • • • • • . • • . • . . • 4. ICJ''/ Exposed Ceiling: Exposed, open beam ceilings are where the underside of tPiordofdecking • can e viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 5J3°II8 Owner/ nt's Signature Date Contra Signature Date i 13a Nit 91 91'1W, f (KM If f,33(ft Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number iami Shores Viii Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTINGSIJE• s • BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES' •. • •; •;; • •, PERSUANT TO SECTION 553.844 F.S. • • •• .• • • • •••• •••• • • • • • To: Miami Shores Village Building Department • • • • . • • • • • Hate: • • • 10050 NE 2nd Ave •••••• •••••• Miami Shores, FI 33138 •• •• • • • Re: Owner's Name: ,)eeyn,) cfct {�, \r\ kA :• •• ° • • • • Property Address: C w - i j '51 • • • • • • Roofing Permit Number: Dear Building Official: y7E;4.5.-IC:c7.‘(� fi f certify that i am not required to retrofit the roof to wall connections of my building because: ❑ The just valuation for the structure for purpose of ad valorem taxation is Tess than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature J 51 tA 6e r-jFt uJ Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/sh,e is the owner for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large day sn of F. DANIEL PEREZ Notary Fublic- State of Florida Commission GG 44769 sFcc:� ?c My Comm. Expires Nov 3, 2020 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for th 'Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.gov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). .... This NOA shall not be valid after the expiration date stated below. The Miami -Dade Caunty.Produci • • • • • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dadetoanty) • • • . reserve the right to have this product or material tested for quality assurance purposes. If'th l5roduct or material fails to perform in the accepted manner, the manufacturer will incur the expens"e'df s'iich testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material withintjipir, • jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Milrpi-j hde County . Product Control Section that this product or material fails to meet the requirements of tbr..dpplicable' .. • • building code. • • . • • This product is approved as described herein, and has been designed to comply with the Florida Building bode • including the High Velocity Hurricane Zone of the Florida Building Code. ' • • • • • .. • • • • • ••• • DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. . LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 1 of 31 ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design TRADE NAMES Product GAFGLAS® Ply 4 Tri-Ply® Ply 4 GAFGLAS® F1exPly 6 GAFGLAS®#75 Base Sheet Tri-Ply®#75 Base Sheet GAFGLAS®#80 Ultima'Base Sheet GAFGLAS® Stratavent® Perforated Venting Base Sheet GAFGLAS® Stratavent® Nailable Venting Base Sheet Ruberoid® 20 Smooth Ruberoid® Mop Smooth Ruberoid®.Mop Smooth 1.5 Ruberoid® Mop Plus Smooth Ruberoid® HW 25 Smooth Pressure: Roofing BUR Fiberglass Wood -97.5 psf. OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 MIAMI•DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide Test Specification ASTM D2178 ASTM D2178 ASTM D2178 ASTM D4601 ASTM D4601 ASTM D4601 ASTM D4897 Product Description Smooth surfaced asphaltic ply sheet reinforced with fiberglass mat. Smooth surfaced asphaltic ply sheet reirorced with fiberglass mat. . . . .. . ... . .. Smooth surfaced asphalticIJ1 ti et reinforce$ • with fiberglass mat. .... .... • Smooth asphaltic base or baWpiy sheet r'etiforced with fiberglass mat. . . . • • ..• .. ••••• Smooth asphaltic base or bpe/ sheet reinforced with fiberglass mat. ' • . • . Smooth asphaltic base or basee/ply'sheetitiV15=ced with fiberglass mat. Smooth surfaced asphaltic perforated venting base sheet reinforced with fiberglass mat. ASTM D4897 Smooth surfaced asphaltic nailable venting base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. ASTM D6163 SBS polymer -modified asphalt base or anchor sheet reinforced with a fiberglass mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6163 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 2 of 31 • • • • • • • • • • • • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Ruberoid® HW Smooth GAFGLAS® Mineral Surfaced Cap Sheet Tri-Ply® BUR. Granule Cap Sheet GAFGLAS® EnergyCap'T' Mineral Surfaced Cap Sheet Topcoat® Surface Seal SB Topcoat® Membrane Topcoat® MB Plus Topcoat® FireOut' Fire Barrier Coating VersaShield®Fire- Resistant Roof Deck Protection VersaShield® Solo' Fire -Resistant Slip Sheet Topcoat® FlexSear Dimensions 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 5 or 55 gallons 1, 5 or 55 gallons 5 or 55 gallons 5 or 55 gallons 12" x 100' rolls 42" roll wide, 100 ft. MIAMI•DADE COUNTY APPROVED 1, 5 gallons or 1 qt. tube Test Specification ASTM D6164 ASTM D3909 ASTM D3909 ASTM D3909 ASTM D6083 ASTM D6083 Proprietary Proprietary ASTM D226 ASTM D146, D828, D4869, D6757 TAS 139 Product Description Smooth surfaced torch applied SBS base or anchor sheet reinforced with a polyester mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Cap sheet is factor coated with TOPCOAT® EnergyCote'T' Elasto • Coating. • • . ..• . •.• • • • .. Solvent -based thermoplastic r*bber • sealant designed to protect aactiestore agedjoof surfaces and to increase roof reff7.8etivity.. • • •' Water -based elastomeric coating • • . . .•• .. • . . Water based, low VOC primer designedtvblotk asphalt bleed -through. • • • • .. •. . Low VOC, water based fire barrier coating • Non -asphaltic, fiberglass reinforced underlayment and/or fire barrier Non -asphaltic, fire resistant fiberglass underlayment Solvent -based elastomeric sealant. NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 3 of 31 APPROVED INSULATIONS: Product Name EnergyGuardTM Polyiso Insulation TABLE 2 Product Description Polyisocyanurate foam insulation Manufacturer (With Current NOA) GAF' EnergyGuardTM Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard' Ultra Polyiso Glass -faced polyisocyanurate foam insulation GAF Insulation EnergyGuard'M RA Polyiso Insulation EnergyGuard' RA Composite Polyiso Insulation EnergyGuardTM RH Polyiso Insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or permalite Polyisocyanurate foam insulation GAF GAF .•••• . . . GAF •• • ••GAF •.... • EnergyGuardTM RH Tapered Polyisocyanurate foam insulation • Polyiso Insulation EnergyGuard' RN Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard' Perlite Roof Perlite insulation board Insulation .... . • . . . .. .. .. .. GAF • . . . • . . • . • • • 'AF • . • ..• EnergyGnardTM Perlite Recover Perlite recover board GAF Board Securock® Gypsum -Fiber Roof Gypsum board United States Gypsum Corp. Board Securock® Glass -Mat Roof Glass faced gypsum board United States Gypsum Corp. Board Structodek® High Density Fiber High density fiberboard Blue Ridge Fiberboard, Inc. Board Roof Insulation DensDeck® Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck® Roof Board Gypsum board Georgia-Pacific Gypsum LLC MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 4 of 31 APPROVED FASTENERS: Fastener Number Product Name 1. Drill-Tec'T` #12 Fastener 2. Drill-Tece" #14 Fastener 3. Drill-Tec' ASAP 3S 4. Drill-Tec" 3" Steel Plate 5. Drill -Teo' 3" Standard Steel Plate 6. Drill-Teoe' AccuTrac® Flat Plate 7. Drill-Tec'"' AccuTrac® Recessed Plate 8. Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) MIAMIDADE COUNTY APPROVED TABLE 3 Product Description Phillips head, modified buttress thread, pinch point, carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. Truss head, self -drilling, pinch point, high thread fastener for use in steel, wood or concrete decks. Drill-Tec""` #12 Fastener with Drill-Tec" 3" Standard Steel Plate. Round Galvalumee steel stress plate with reinforcing ribs and recessed for use with Drill -Teem fasteners. Galvalume® coated steel stress plate for use with approved Drill-Tec° fasteners. A2-SS alnmini7ed steel plate for use with Drill-Tec"'' fasteners. Galvalume® steel plate with recess for use with Drill- TecT"' fasteners. Round Galvalume® plated steel stress plate with reinforcing ribs for use with Drill-Tec'" fasteners. Manufacturer Dimensions (With Current NOA) #12 x 8" max. length, #3 Phillips head. #14 x 16" max. length, #3 Phillips head. • •• • See • components •••• • • 3" Round GAF . GAF GAF •••• • • • • • • • • • 'AF•• • • • • •. . • • . . •• • • • • 3" Round • • • • • GAF. • . . •••. • . •.•• • • • •• •• • •• 3" square; .017" thick 3" square; .017" thick 3" Round •. • GAF GAF GAF NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 5 of 31 • • • • EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. UL LLC PRI Construction Materials Technologies, LLC Test Identifier 3014547 3029832 3033135 3034312 3036980 3038278 " 3040738 3041769 3042887 3042905 3046081 3047636 OD0A8.AM OD1A8.AM 0Y9Q5.AM 1B9A8.AM 2B8A4.AM 3B9Q1.AM 3D4Q2.AM 797-03221-267 797-03825-267 797-10228-267 R1306 GAF-012-02-02 GAF-020-02-01 GAF-082-02-01 GAF-084-02-01 GAF-122-02-01 GAF-270-02-02 GAF-276-02-01Rev GAF-276-02-02 GAF-306-02-01 GAF-314-02-01 GAF-315-02-01 GAF-3 69-02-01 GAF-417-02-01 GAF-464-02-01 GAF-464-02-01 GAF-499-02-01 GAF-500-02-01 GAF-549-02-01 GAF-549-02-02 GAF-559-02-01 Description 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 4470 UL 790 • . • •. • • •.. • • • .... .. .• . . ASTM D4977 . ASTM D4977 ASTM D6083 ASTM D6083 TAS 139 ASTM D226 ASTM D6083 ASTM D226 ASTM E96 ASTM D2178 ASTM D2178 ASTM C1289 ASTM C1289 ASTM C1289 ASTM C1289 ASTM D6083 ASTM D6083 TAS 114 TAS 114 TAS 117(B) . . • • • • Date 05/22/03 05/11/07 11/24/08 04/09/09 08/14/09 11/18/11 11/16/10 05/26/11 11/14/11 01/10/12 02/13/13 08/08/13 07/09/99 07/29/94 04/01/98 .'69)t4/97 • •O'3%2/97 0?/j/98 05/30/97 •09/c7/07 • •'03h21/08 •'O1,/23/15. 04/04/17 :'PP/OS/01 • • 02/01/02 • • '0►5M7/06 05/09/06 05/07/06 11/15/10 12/16/10 11/15/10 07/07/11 08/23/11 08/23/11 10/22/12 05/28/13 10/22/12 02/06/14 03/12/14 03/12/14 08/08/14 08/08/14 09/30/14 NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 6 of 31 EVIDENCE SUBMITTED: (CONTINUED) Test Agency PRI Construction Materials Technologies, LLC IRT of S. Fl. Trinity I ERD Atlantic & Caribbean Roof Consultants, LLC MIAMI•DADE COUNTY APPROVED Test Identifier GAF-559-02-04 GAF-559-02-05 GAF-559-02-06 GAF-559-02-07 GAF-559-02-08 GAF-559-02-09 GAF-559-02-11 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559-02-16 GAF-559-02-18 GAF-559-02-19 02-005 02-014 C8500SC.11.07 G30250.02.10-3-R2 G31360.03.10 G33470.01.11 G34140.04.11-2 G34140.04.11-4-R2 G34140.04.11-5-R3 G36780.07.11-R1 G40630.01.14-1 G40630.01.14-2A G40630.01.14-2A-1-R1 G43610.01.14 G6850.08.07-1 SC6870.08.14-R1 Description Date ASTM D 1876 10/01/14 ASTM D 1876 10/15/14 TAS 114(H) 10/02/14 ASTM D 903 10/02/14 ASTM D 903 10/02/14 ASTM D 903 10/02/14 TAS 114 10/14/14 TAS 114 10/14/14 TAS 114 10/15/14 TAS 114 10/15/14 TAS 114 10/15/14 TAS 114 10/15/14 TAS 114 10/15/14 TAS 114 04/16/15 TAS 114 4,Q1418/02 TAS 114 . . •.03622./02 . . . • • TAS 117 •• ••11430/07 •• ASTM D3909 • 06/03/15 ASTM D6164 .... .Q. I31/10 • ASTMD6164•••••• }},05/11 ASTM D6163 . . •04/Z/11 ASTM D6401 • • • • •06it 4/15 ASTM D4897 • •• •• 0�/04/15 •4470-TAS 114, • • 03/18/11 ASTM D6163 •.. • •.O1/D6/14 . • ASTM D6164 • At/0,/14 ASTM D6164 04/10/14 ASTM D3909 01/22/14 ASTM D3909 08/13/07 ASTM D3909 09/04/14 .• 11-053 TAS 114 08/12/11 NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 7 of 31 • Membrane Type: Deck Type 1: Deck Description: System Type E(1): BUR Wood, Non -insulated 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: (optional) Base sheet: Fastening Option #1: Fastening Option #2: Ply Sheet: Cap Shee j Surfacing: Maximum Design Pressure: • • .... •1/••I• (Maximum Design Pressure —52.5 psf See General Limitation #7) • • • • • ' • ... . .. GAFGLAS® #80 Ultima Base Sheet, Ruberoid Smooth oreid®Mop Smooth • attached to deck with approved 11/4" annular ring shank nails and'ift 4ed 3"Steel late ara • .fastener spacing of 9" o.c. at the 4" lap and in two rows staggeredwith a fastener spacing o1 • •. 9" o.c. in the center of the membrane. • Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection, VersaShield® Solo" Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. GAFGLAS® #80 Ultima' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid® 20 Smooth, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Flex Ply' 6, GAFGLAS #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of- the above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9"•e epin the ( field. • . . . E.One or more plies of GAFGLAS® Ply 4)Tri-Ply® Ply 4 or GAFGLASf#80131 xa i3ase • Sheet adhered in a full mopping of approved asphalt applied wit the,EVT r i gq, and at p. rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. • . • (Optional One ply of GAFGLAS® Mineral Surfaced Cap Sheet)rri-Ply® BUR Granule Cap Sheet or GAY'EnergyCap Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. MIAMIDADE COUNTY APPROVED . . • • • • (Maximum Design Pressure —60 psf. See General Limitation #.7.) .. See Fastening Options NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 25 of 31 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply` 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeck' Roof Board or 'A" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows) one at each sidelap and one down the center of the sheet allowing a continuous area of ventil ion. • Encirctipm,f4the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow crdss.deiZtilation..Asphalt • • application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attaehed systems seal; be limited to a maximum design pressure of -45 psf. • 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force.altalue of.27? ilaf., as ' • tested incompliance with Testing Application Standard TAS 105. If the fastener value; as Meld-testeci,•are below • • 275 lbf. insulation attachment shall not be acceptable. • • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachmvZi:i&ltased on a.minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should thee.: . fastener resistance be less than that required, as determined by the Building Official, a ievi •erl fastener spacing, • • prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or ettiSt@red • ' Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When. this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofmg Application Standard RAS 11.1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 31 of 31 The 'hoof deck;mayi first be coveted with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS® Stratavent® Nailable Venting Base e, 5heet'4.oi;''GQFGLAS® Stratavent® Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing . aipTia it arid nailable base sheets are to be mechanically fastened. granule side down. °As.anoption Type.G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® 480 UltimaTM PBase ly 4" or e Tri Ply® Ply 4" or GAFGLAS® Flex Ply 6"eor'"Trng BPIy® Ultrase a -Flexible ex ble Ply 6) may be °) as the nailed base ply in thted for Type GI asphalt e follss owing r systems. sheet GAFGLAS® Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS® Flashing" or "RUBEROID®" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes any UL Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems fisted. Structural cement fiber building units are considered suitable to be included as a deck.in the following Class A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Cass A, B or C systems does not adversely affect the rating. The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS® #80 Ultima.'" Base Sheet" may be used in any of the following systems. "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United CoatingsTM FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2. Class A, B and C Hot roofing asphalt, for use with glass felts or modified bitumen membranes. . "RUBEROID® Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROID® Mbp" SBS roofing Classification. Class A •••• • • • • •••• • • • •• •' ••• • rnerr:br-anes in any al3plitable • • � • • • •••• •••• • • • • • • •••• •••• • • 1. Deck: C-15/32 Incline: 3 • • • • • • • •• •• •• •• Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum L`c;gerysDeck® Roa fboard" or • • "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in, thick United -States GypsumCo. • "SECUROCK® Roof Board° (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Vapor Barrier (Optional): — One or more plies "GAF® SA Vapor Retarder" self -adhered • ; • • . • • • Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane•or pai'Iite/poIyisoc anurate. • composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. ••. • . • Ply Sheet: — Three or more plies Type Gi "GAFGLAS® Ply 4" or 'Tr -Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tr -Ply® Ultra -Flexible Ply 6", fully adhered with hoot roofing asphalt. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick.United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type Gi "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Fiex Ply 6" or "Tr -Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapm Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 3. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board".(Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, 2-in. maximum. Ply Sheet: — Two or more plies Type Gi "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hotroofing•asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. Incline:1 Slip Sheet (Optional): — Red rosin paper, nailed to deck. ittp://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=TGFU.R1306&ccnshorttitie=Roofing+Systems&objid=1074351... 2/48 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with 'O"t40 ins2gyBonstastening,,Systeri4gLailation adhesive. `. p •b .c'e •8heet• — One pl�Ty_pe G2 GAFGLAS® #75 Base Sheet'•4 or 'Tri-Ply® #75 Base Sheet' or 'GAFGLAS® #80 UltimaTM Base Sheet" or i AFGLAS®'Strataven LVa.ilabl.e�lenl:Gna_easCsheet"� mechanically fastened. • [PIy sheet= Ore plies eo Gl AFGLAS® Pii 4'.L for "Tri-Ply® Ply 4" or GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply fullyaci er_'etwitb hot roofing asphalt. "Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced CapSheet;'i'or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM Mineral -Surfaced Cap Sheet", fully adheres wit hot roofing asphalt. Coating (Optional): — "United Coatings."' TOPCOAT® EnergyCoteTM Roof Coating" or "TOPCOAT® MB Plus Coating" or "United CoatingsTM Roof Mate MB Plus Coating" applied at a rate of 2-gal./100-ft.2. 5. Deck: NC Incline: 3 Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT"" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 6. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation: — One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or phenolic, 1-in. minimum (offset a minimum of 6-in. from plywood deck joints). Base Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6" or "Tri-Ply® Ultra -Flexible Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima.Tt" Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-Ply® APP Smooth" or "RUBEROID® Torch Granule" on. • • "RUBEROID® Torch 180" or "Tri-Ply® APP Granule", torch applied or "RUBERDID® Mop Smooth" or "RUBEIOID( Mop Snntaptly YS" or "RUBERDID® Mop Plus Smooth" or "RUBERDID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SBS Granule" fu!Ily�edhered with hot • •• • ••• • • roofing asphalt. • • • Cap Sheet — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or 'Tri-Ply® BUR Granule Cap Sheet" or ' k?f lS® EnergyCaQ'y Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • • • 7. Deck: C-15/32 Incline: 2 •••• • • • • • • • • • • • • • • •••• • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "Denslac%NRoofbaerd'Lor: "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick United ShtLs rpsum Co"• • • "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • • • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or • • • perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite Qr phenolic, ant tJTitler}2ss. • • Base Sheet: — Two or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or 'CAMAS® #80 Uitimam Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforatedtentig Baso Met; • • "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type 65 • "GAFGLAS® Mineral Surfaced Cap Sheet" or 'Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6 or 'Tri-Ply® Ultra - Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or 'Tri-Ply® APP Smooth" or "RUBERDID® Torch Granule" or "RUBEROID® Torch 180" or 'Tri-Ply® APP Granule", torch applied or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBERDID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SOS Granule" fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT"' Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 8. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'm Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX G) or "SECUROCK® Glass -Mat Roof Board". (Type SGMRX). Insulation (Optional): — Perlite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened, any thickness. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. PIy Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Piy 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet', fully adhered with hot roofing asphalt. Coating: — "United CoatingsT"" FireShield MB Roof Coating' applied at a rate of 2-1/2 to 3-gal./100-ft.2. 3. Deck: C-15/32 Incline: 1 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). //database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnshorttitle=RoofingtSystems&objid=1074351... 3/48