Loading...
RF-18-1498Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit NO. RF-5-18-1498 Permit Type: Roof Work Classification: Tile Permit Status: APPROVED tesue Date: 6/1112018 Expiration: 12/08/2018 Parcel Number Applicant 10642 NE 10 Court Miami Shores, FL 33138- 1122320280940 Block: Lot: CHRISTOPHER AVINA Owner Information Address Phone Cell CHRISTOPHER AVINA 10642 NE 10 CT MIAMI SHORES FL 33138-2102 Contractor(s) ACEBO ROOFING CORP Phone 305-685-2534 Cell Phone Valuation: $ 24,700.00 Total Sq Feet: 3400 Type of Work: Re Roof Additional Info: RE -ROOF TILE AND FLAT Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $15.00 $4.88 $3.25 $5.00 $325.00 $9.00 $20.00 $882.13 Pay Date Pay Type Invoice # RF-5-18-67767 06/11/2018 Credit Card 05/31/2018 Credit Card Bond #: 3793 Amt Paid Amt Due $ 832.13 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type:, Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume re onsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, P G, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFI construction that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating e, - u orize the above -named contractor to do the work stated. ature: Owner / Applicant / Contractor / Agent June 11, 2018 Date Building Department Copy June 11,2018 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number: INSP-000565-2018 Permit Number: RF-5-18-1498 Scheduled Inspection Date: October 11, 2018 Inspector Naranjo, Ismael Owner: CHRISTOPHER AVINA Address: 10642 NE 1&k+vT MiaSh e..:; 133138 Project: <NONE>,' Contractor: ACEBO ROOFING CORP PEDRO ACEBO Permit Type: Roof Inspection Type: Roofing Final Work Classification: Tile Phone Number. Parcel Number: 1122320280940 Phone Number: 3056852534 Building Department Comments RE -ROOF TILE AND FLAT Checklist Item General Comments Passed False Comments Inspector Comments Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. October 10, 2018 For Inspections please call: 305-762-4949 Page 24 of 28 BUILDING PERMIT APPLICATION BUILDING 0 ELECTRIC PLUMBING El MECHANICAL Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 62` ` FBC2014 Master Permit No. AZ..c tg kL--kGej Sub Permit No. ROOFING El REVISION EXTENSION RENEWAL PUBLIC WORKS Ei CHANGE OF ri CANCELLATION 0 SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 10642 NE 10 COURT, MIAMI SHORES, FL. 33138 City: Miami Shores Folio/Parcel#:11-2232-028-0940 Occupancy Type: County: Miami Dade Load: Construction Type: Zip: Is the Building Historically Designated: Yes 'NO X OWNER: Name (Fee Simple Titleholder): CHRISTOPHER AVINA Address: 10642 NE 10 COURT Flood Zone: BFE: FFE: 864886890 Phone#: 7 City: MIAMI SHORES State: FL Tenant/Lessee Name: Phone#: Zip: 33138 Email: CONTRACTOR: Company Name: ACEBO ROOFING CORP Address: 4305 E 10 LANE Phone#: 3056852534 City: HIALEAH State: FL Qualifier Name: PEDRO L. ACEBO zip: 33013 Phone#: 3056852534 State Certification or Registration #: CCC058112 Certificate of Competency #: DESIGNER: Architect/Engineer: 1.1 A Phone#: Address: / City: State: Zip: Value of Work for this Permit: $ 2-1-4170C) • Square/Linear Foo age of Work: 39 66 to Type of Work: ❑ Addition n Alteration ❑ New . Repair/Replace ❑ Demolition Description of Work: REROOF ; / Z e., ? .p` /4T Specify color of color thru gz6 Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond$ S° TOTAL FEE NOW DUE $ �� • 121' Bonding Company's Name (if applicable) Bonding Company's Address y City State Zip Mortgage Lender's Name (if applicable)4 Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the' first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENT The foregoing instrument was acknowledged before me th Z-V. day of /- 'c , 20 r)- 746p 4.Jl._Qd Vb 4who i me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign:t Print: Seal: ,ro� '*<< PAOLA BASSI ,�. Notary Public - State of Florida Commission # FF 966918 •.,,o FF,\." My Comm. Expires Mar 13, 2020 APPROVED BY 8 CONTRACTOR for :fpi "'. instrument was acknowledged before me this , 20 18 , by as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign. Print: Seal: s Notary Public - State of Florida =�, Commission # FF 966916 , -� o- .' My Comm. Expires Mar 13. ******************* ******************************************* Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Bonding Company's Name (if applicable) Bonding Company's Address �1 City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. iSignaturE OWNER or AGENT The foregoing instrument was acknowledged before me this H day oftsls*e_ S. 'Ll.TO4? ! -P� AViJ. n, who is me or who has produced ,2018 , by identification and who did take an oath. NOTARY PUBLIC: Prii Sea PAOLA BASSI Notary Public - State of Florida Commission # FF 966918 '88FAoos• My Comm. Expires Mar 13, 2020 *************************** APPROVED BY as Signature CONTRACTOR The foregoing instrument was acknowledged before me this Li day of �U ,2018 ,by pe��fs C7 who personally known me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign. — —— Print, Seal:, PAc,; ;, BASSI PAOI A BASSI `,'T.:. Notary Public - State of Florida •c " iTt Commission # FF 966918 y�` "oT .;rso,f,o,' My Comm. Expires Mar 13, 2020 // /Pans Examiner as Zoning (Hevised02/24/2014) Structural Review Clerk CO frr S T Florida Building Code 6th Edition (2017) Uniform Permit Application Form Section A (General Information) Master Permit No. Process No. Contractor's Name__ ^`3V,;, f' ! •'�t'_l.[... C Tr Job Address.__,, ROOF CATEGORY Low Slope 0 Mechanically Fastened Tile 0 Asphaltic Shingles ❑ Metal Panel/Shingles 0 Prescriptive BUR•RAS 150 ROOF TYPE ❑ Maintenance /Reroofing J�Z ROOF SYSTEM INFORMATION 11 Low Slope Roof Area (SF) „?C Steep Sloped Roof AREA (SSF)Z�%[4Z 0 New roof 0 Repair •D Morta dhe ve Set Tifes , 0 Wood Shingles/Shakes 0 Recovering Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow dr sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. • • •• ••• • ••• • • • • • • • • •• • • ••• • • • • • • • • • •• • ••• • ••• • • • i a • • • • • •• fie ••• • (P•• ••• • • • • • • • ••• • • 000 • • • • • . • ••• • • • • • • • . • • • • •• •• • 1100 • • Total (SF)_ 4:),0 f2" Florida Building Code 6th Edition (2017) Uniform Permit Application Form Section C (Low Slope Application) Fill in specific roof assembly components and identity manufacturer (If a component is not used, identify as "NA") System Manufacturer: GAF Product Approval No.: 1.3-1022 1.5_ Design Wind Pressures, From RAS 128 or Calculations: P1:.__ 42.8 P2:..._ ....__71,7 P3: 108.,0 Top Ply Fastener/Bonding Material: HOT ASPHALT_.__._ Surfacing: _N/A_ Fastener Spacing for Anchor/Base Sheet Attachment: Field: _.9 " oc ® Lap, # Rows 2.._ @ 9 " oc Perimeter:.._6__" oc @ Lap, # Rows _4_ 45)_6 " oc Corner: 4_._." oc ® Lap, # Rows _6_ @ 4 " oc Number of Fasteners Per Insulation Board: Or Field __N/A Perimeter _N/A, Comer _N/A,., Max. Design Pressure, from the specific product approval system: Deck: Type:_.WOOD___ ___. Gauge/Thickness: 3/4" Scope:_.__ 0;,12,,.�. Anchor/Base Sheet & No. of Ply(s):.LP_LY_#z5_GAE_BASESHEET Anchor/Base Sheet Fastener/Bonding Material: 1-1/4" R/S W/ TINCAP Insulation Base Layer: N/A Base insulation Size and Thickness: _.,_N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: ____.._._.WN/A ._ Top Insulation Size and Thickness: __ N/A Top Insulation Fastener/Bonding Material: N/A_. Base Sheet(s) & No. of Ply(s): �. Base Sheet Fastener/Bonding Material: _ N/A .__..........__�__.___..... Ply Sheet(s) & No. of Ply(s): _._._ 1_P_L.Y_RUBEROID.20 Ply Sheet Fastener/Bonding Material: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 9" STRIP 3X3 26 GAUGE GALVANIZED DRIP WOOD #75 GAF BASE RUBEROID 20 . • • •• • • • •• • • • •• '• ••: MINERALSWRFAC_. • • • CAZ' SHEE: • • HOT ASPHALT _•!• ••• ••• . • • • •• . . . • • • . • . . • • Top Ply:.,_IT m GAF. MINERAL.,SUREACE.CAPSHEET '. • • • • • •• • ; : : • • • • • • • • • • • • • • • .•• • • • • • • • • • • • • • • • • • • • • . • •• • • • • • • • • • • • • • • .• • FT. Parapet Height Mean Roof Height Florida Building Code sth Edition (2017) Uniform Permit Application Form Section D (Steep Sloped Roof System) BORAL Roof System Manufacturer N_ Notice of Acceptance Number: 16-0711.04 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: 4.70_ P1:._ 13.84-___ P1: .41Q Deck Type: Roof Slope: 3 : 12 Ridge Ventilation? N/A Mf=26.1 WOOD Type Undertayment: #30 ASTM 226 TYPE 2 Mean Roof Height: N/A insulation: I N/A Fire Barrier: N/A p Spacing: 1-1/4 R/S NAILS WITH 5/8"TIN CAPS 6" O.0 ON LAPS Fastener Type O� 2 ROWS 12" O.0 FIELD Adhesive Type: HOT ASPHALT Type Cap Sheet: #90 / TILE UNDERLAYMENT Roof Covering: VILLA 900 Type & Size Drip Edge: • . . • . . . .• ••• •• . . . .. • •• •.. •.• • • • • . •'. • . . . • . . •• . ••• .. •.• • •. . . • • • •.. ••. ".• • • • • • • • • ... . . • • . . . . . •• • . . • .•. .. .. . . • .. .. • • • 000 • . ... • • • ... . • 3X3 26 GAUGE GALVINIZED Florida Building Code 6th Edition (2017) Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127' (P1:_39.1 x ?..31,5_ = 12.32) - Mg _7_62. = M,, 4.70.. (P2:_68.1 X?...315_ = 21..46.) - Mg: _7_62 = Ma .13.84 (P3: 1.00.7 XX ,,3.15_ = 31...72) - Mg: _7.62 = Me, .24_1.0 Product Approval M, ._...26.1 Product Approval M, Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M, M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' 25° 30' 40' 2:12 34.4 36.5 38.2 39.7 • 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 . 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. (P1: xL (P2: x L (P3:-�_ x L Method 3 "Uplift Based Tile Calculations Per RAS 127" x w: = ) - W: x cos 0 = F,, _.._ _ Product Approval F' __ x w: = _.) - W: x cos O = Fr; ___ Product Approval F x w: _ .__.._) - W: _....._. x cos 0 = F:; .__._ Product Approval F' _. ,,._... _ ..... Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope Aerodynamic Multiplier 0 Job Site ?. Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Ma Calculated Minimum Attachment Resistance F' •• 1141• Required Uplift Resistance •�ProductApproval F, : • •• ••Carcarfated; •.• • • • • • • Average Tile Weight • W • • • • • • •�•• •width • • Pjocic:Alprowal- _._.___. Tile Dimensions IAIi calculations must be submitted to the , = length W _ building official at She time of permi -•_- ProducrAkprbGal application. • • • •• ••• ••. • • • • • • • • • • .• •• •.• • •• • •• • • ••• • • • • • • • . • • • • . ••• • • • • • • • •• •• • • ••• • • • • • • • • • • • • • • •• 0• SECTION 1524 HIGH VELOCITY HURRICANE ZONES -REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). J 4. --Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. C 6 —,______Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be nec-ssa i to install overflow scuppers in accordance With the requirements of Sections R4402, R4403 . d ' - 13. Owner/Agentnignafure Date Contractor ature Date KIPS- ice Ca. - Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • • •• •. . . • • ••• • • . • • • • • . . • • • • • . .. Oil •• • •• • • • • • ••• • . • • ••• • • • • ••• • • • •. • • • • :: • • • • • • •, • • • ' . . • • • • • • ••.•• • • • •• .• . Revised on 5/21/2009 iamihores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: o\1\•(.s� Property Address: IOW 2- Roofing Permit Number: Dear Building Official: I Ckt)(Ai-CA9 building because: Date: certify that I am not required to retrofit the roof to wall connections of my 'The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) State of Florida County of Dade *7k-fl VtlQ Print Name •• ••• • • • • • •• The undersigned, being the first duly sworn, deposes and says.that tietst>� t it►e rn@'nertor the above property mentioned. .r ... . n • . -- Sworn to and subscribed before me this Notary Public, Sate of Florida at Large IVbtaTy Qdbjic - Stitt o f tlerida 4omreission #4F 96691)i m MyCemExpires Mar 13, 2i)20 • When the just valuation of the structure for purpose of ad valorem taxation is 444 tor morerthv $400440.00,•and the•bulding was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the:Roof to4ll.cinnec.Lion !-iurrican:Mitigatiori. • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.Qov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AI-IJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to'perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Boral Villa 900 Concrete Roof Tile LABELING: -Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall he provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0308.20 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigerx• ••• • • • • • •• MIAMI DADE COUNTY APPROVED • • . . • • . . . . . • �:'.•-r • • • .• • • •.. •.• • . . •• • • •• •• • •• • • • •.i:� 1,1: •• • •• • t. . • . .. • •• • • .• •. • . • . •. • .• • •.• •.. • . •.• • . . • .•• • . • . • • • • • • . ..• • • • • •. • . • . • • . . • . •• .. . • •. .. .. •.. • . • •• ... . . NOA No.: 16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing. LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations vvhere the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Boral Roofing Villa 900 Length = 17" Width = 13" '/2" thick Trim Pieces 1 = varies w = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Test Specifications TAS 112 Type 1 b Class I11 TAS 112 Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with three nail holes and double rolls. For direct deck, batten, mortar or adhesive set applications. Accessory trim. concrete roof pieces for use at ridges, hips and rakes. Product Name Product Description ICP Adhesives Polyset AI-I-160 Two component polyurethane foam adhesive. ICP Adhesives Polyset.RTA-1 Single component polyurethane foam roof tile adhesive. TILE BONDTM Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. "Tile Tite" Roof Tile Mortar Premixed. pre -bagged roof tile mortar. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales. FL MIAMIDADE COUNTY APPROVED .. ... . . . . • • Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. The Dow Chemical Company Bermuda Roof Co. Inc. • • • .. .. ... .. • ... • . . • . • . • . • • . .. • • . • . . ... . • . • • . • • • • . . • • . . . .. . . .. . . . . • ... ... . • . ... • • . . • ... • • • • . • . . . • . • .. .. . ... . . NOA No.:.16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 Page 2 of 7 2.3 EVIDENCE SUBMITTED Test Agency Nutting Engineers Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering. Inc. Walker Engineering. Inc. Walker Engineering. Inc. Walker Engineering, Inc. Walker Engineering. Inc. Walker Engineering. Inc. Walker Engineering, Inc. American Test Lab of South Florida MIAMI•DADE COUNTY APPROVED Test Identifier Test Name/Report 13343.1 TAS 112 7161-03 Static Uplift Testing Appendix III TAS 102 & TAS IO2(A) 7161-03 Wind Tunnel Testing Appendix II TAS 108 (Nail -On) P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails 94-060B Static Uplift Testing TAS 101 (Adhesive Set) 94-084 Static Uplift Testing TAS 101 (Mortar Set) P0631-01 Wind Tunnel Testing TAS 108 (Mortar Set) Letter Dated Aug. 1, 1994 Wind Tunnel Testing TAS 108 (Nail -On) Project No. 307025 Wind Driven Rain Test #MDC-76 TAS 100 25-7183-1 25-7183-2 25-7214-2 25-7214-6 528454-2-1 520109-2 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Static Uplift Testing TAS 101 25-7183 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Evaluation Calculations Aerodynamic Multipliers Evaluation Calculations... •`Lwi> 4'ateAQh�iVSet System • . • • • . . • • • Evaluation Calculations • lest•tr:ng;N2ol�l�l t Utz to Gravity RT0617.02-16 ��• •• • TNS• 1 T2 • .•. •.• . . • • • • • • • • •• • • • •• • • •• • . • • 40 • • • • • • • • • • • • 440 • • • • • • • ••• ••• • • .. . • • • 4100 • • • . • • • • . • • . • •.• . • • • . • • • . • • • . • . • • • . • • • . 00 •.• • • • ••. • • Date Apr. 2006 Dec. 1991 Dec. 1991 Sept. 1993 March, 1994 May 1994 July 1994 Aug. 1994 Oct. '1994 Feb. J 1995 March. 1995 Sep. 1998 Dec. 1998 March 1995 February 1996 April 1996 December 1996 09/01/16 April 1999 09/01/16 06/29/16 NOA No.: 16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall he performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise, by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Rooting Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile X (ft3) X (ft3) Profile Batten Application Direct Deck Application Villa 900 Concrete.Tile 0.291 0.315 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 MIAMI•DADE COUNTY APPROVED • • . . • • • •• ..• • • . • • •• •• •.. •. • • . •• • ••• ••• • • • • • • • • • • • . • • •• •• • • • • It• •• • • • . . • • • • • • • • • • • • • • • • • •.• ••• • ••• • • • • .•• • • • • • • • • • • • • . •.• • • • • • • • . • . • • • • • • e • • . • . • • . • 4100 • • • .•• • • NOA No.: 16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment,- Mr (ft-Ibf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Villa 900 Concrete Tile 2-10d Ring Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile Adhesive' 26.12-3 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond one -component foam, minimum weight per paddy 11.4 grams. 3 ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile ICP Adhesives Polyset® AH-160 two -component foam 86.614 ICP Adhesives Polyset® AH-160 two -component foam 45.55 4 Large paddy placement of minimum 54 grams. 5 Medium paddy placement of minimum 24 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile TUC ••• • APP Gcatiorl • •. • • • • . • ; ; •• Attachment Resistance Villa 900 Concrete Tile • MoriblI.Se44 20.60 6 Tile-Tite Roof Tile Mortar. •• • •'. ..*. MIAMI•DADE COUNTY 1 APPROVED • ••• ••• • • • • • • • • • • • • • • • • • •• . • • • • • • • • •• • • • • •• •• • • • • • • • ••• ••• • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 Page 5 of 7 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL VILLA 900 CONCRETE TILE (LOCATED ON THE..UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED .. ... . . . . . .. • . . . .. ... .. . . . .. . ... • • . • . . • • • . •. ... • • • . ••• ... . • . • . . • . . . • . • . . • •• •� • �• • • NOA No.: 16-0711.04 • ••• ••• Expiration Date: 09/21/21 Approval Date: 09/01/16 • • •• ••• • • Page 6 of 7 • • • • • • • ••• • • • • • • • • • • • • •• • • • •• •• • • ••• • • MIAMI•DADE COUNTY APPROVED PROFILE DRAWING 21/8" r VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE .. ... . . . . . .. • • • • • • • . • .• ••• .. • • • •. • ••• ••• • • • • • • •• •• • • • • • • . •• •• • • • • • •• • . •• • • ••• •• •• ••• ••• ••• NOA No.: 16-0711.04 Expiration Date: 09/21/21 Approval Date: 09/01/16 ••• • • • • •••• •• • Page7of7 • • • • • • . • • • • •.. • • • • • • • • • • • • • • •• •• . • • •• •. ••• • • • ••• • • DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD ANI) CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Fl6rida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidadc.tov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance. if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo. city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials. use. and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided t •the.4ses hiv tl}p m�nlifac`t�lrer or its distributors •and shall be available for inspection at the job site at the requet oftl� te�d•n �C�ff'ciall This NOA renews and revises NOA No. 13-0424.09 and consts'ts • affYages.l tlrough• •' 1C,.. The submitted documentation was reviewed by forge L. Acebo. MIAMI•DADE COUNTY APPROVED . • . ••• • • . . • • . • • • • • . . . •• • •. •• . • . •.1 . • • . .. •• . • • • • • • • • •• •NOA No.: 13-1022.15 Expiration Date: 11/04/18 '• . • •• • •;• ;4ppi val Date: 11/06/14 • •• • ••• ••• ••• ••• •• •• Page I of 16 •• • •• •• • • • •. •• ••• • • • • • • • • Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: ROOFING SYSTEM APPROVAL Roofing BUR Fiberglass Wood -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLASK #75 Base 39.37" (1 meter) ASTM D460I Type 11 asphalt impregnated and coated glass mat Sheet Wide base sheet. GAFGLAS'" #80 Ultima'M 39.37" (1 meter) ASTM D4601 Type II asphalt impregnated and coated, fiberglass Base Sheet Wide base sheet. GAFGLASR FlexPly'" 6 39.37" (I meter) ASTM D2178 Type VI asphalt impregnated glass felt with asphalt Wide coating. GAFGLAS'' Ply 4 39.37" (1 meter) ASTM D2178 Type IV asphalt impregnated glass felt with asphalt Wide coating. GAFGLAS1' Mineral 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet surfaced Surfaced Cap Sheet Wide with mineral granules. GAFGLAS'g' EnergyCap�" 39.37" (I meter) BUR Mineral Surface wide Cap Sheet GAFGLAS' ' Stratavele 39.37" (1 meter) Eliminator"' Perforated Wide Venting Base Sheet GAFGLASr Stratavent`"' 39.37" (1 meter) Eliminator'" Nai lable Wide Venting Base Sheet Ruberoid'' SBS Heat - Weld"' Smooth Ruberoid'R' SBS Heat- Weld'M 25 Ruberoid 20 Ruberoid'' Mop Smooth 39.37" (I meter) ASTM Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) wide MIAMbDADE COUNTY E:::)) APPROVED ASTM D3909 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied I NI EnergyCote ASTM D4897 Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. ASTM D4897 A nailable. fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. D6I64 Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. ASTM D6164 Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. •. ,•• • • • • • •• • • ASTM D6163 •.SBS,c4odi'trecta�pl �l• sbar sheet reinforce with a •tia%s.Gbtalt.• ; • ..• ASTM D6164 Non -woven polyester mat coated with polymer- ••• nicaifienSpl014andogttt•surfaced. • . • • • • • • . • • • . ••• ••• . NOA No.: 13-1022.15 Expiration Date: 11/04/18 • •:. ••1pp val Date: 11/06/14 • • • • •. • • • • • Nage 2 of 16 • •• •• • • • •• •• ••• • • • ••• • • • • V • It • • • • • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification Proprietary Product Dimensions FireOut. "' Fire Barrier 5, 55 gallons Coating VersaShield° Fire 350 sq. ft. roll Resistant Roof Deck Protection Topcoat® Surface Seal 5 gallons SB APPROVED INSULATIONS: Product Name EnergyGuard Polyiso insulation EnergyGuard" RA Polyiso insulation EnergyGuard— RN Polyiso Insulation EnergyGuard" Perlite Roof Insulation EnergyGuard Perlite Recover Board EnergyGuard' RA Composite Polyiso Insulation Securock' Gypsum -Fiber Roof Board Structodekk High Density Fiber Board DensDeck' Roof Board MIAMI-DADE COUNTY APPROVED....) ASTM D226 ASTM D6083 Product Description Low VOC, water.based fire barrier coating. Non -Asphaltic Fiberglass -Based Underlayment. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board. Perlite recover board Manufacturer (With Current NOA) GAF GAF GAF GAF GAF Polyisocyanurate foam insulation with high GAF density fiberboard or Permalite perlite insulation Gypsum roof board High density fiber board Gypsum board • •• .•• • • • . • • • • •• • • • •• ••. .• • • • •• • ••. ••• . • • • . . • • •• . • . • • •• • • •• •.• • • • • •. . •• • • • •. .• • . • •• • • • • ••. ••. •. • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • . • • • • • • • • • • • •• •. • . • United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 3of16 APPROVED FASTENERS: TABLE3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec" #12 Fastener Insulation fastener for steel, various GAF vvood & concrete decks. 2. Drill-1 ec'' #14 Fastener Insulation fastener for steel. various GAF wood & concrete decks. 3. Drill-'l ec'"" XHD Fastener Carbon steel extra heavy duty Various GAF fastener used in steel decks. 4. Drill-Tec" ASAP 3S Drill-Tec'' #12 Fastener with Various GAF Drill-TecT" 3" Standard Steel Plate 5. Drill-Tec 3" Steel Plate Round galvalume stress plate 3" round GAF used with Drill-Tec fasteners. 6. Drill-Tec'' 3" Standard Steel Round galvalume plated steel 3" round GAF Plate stress plate with reinforced ribs for use with Drill-TecT" fasteners. 7 Drill-Tec AccuTracFlat AZ -SS aluminized steel plate 3" square GAF Plate for use with Drill-Tec" #12 Fastener. Drill-Tec'' #14 Fastener and DriII-Tec"" # 15 Fastener. 8. Drill-Tec"' AccuTrac® Galvalume Steel plate for use 3" square GAF Recessed Plate with Drill-Tec'" fasteners. MIAMI•DADE COUNTY APPROVED .. ... . . . . . .. . • . • . . . .. ... .. . . . .. • ••• ... • . . • . . .• .. . . . • • . . • . . .• . . .. • • • . .. .. • • • . • . .• ... ... • ... • • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 • '. • • • Approval Date: 11/06/14 . •• • •• . . • . • . . Page4of16 • .. . • . .. . . • .... • • EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. .LI. 2B8A4.AM 4470 07/02/97 .I.I. 3 B9Q I .AM 4470 01/08/98 .I.1. ODOA8.AM 4470 07/09/99 .I.I. O D I A8.A M 4470 07/29/94 J.I. 0Y9Q5.AM 4470 04/01/98 3029832 4470 05/ 1 1 /07 UL LLC R1306 UL 790 07/22/13 PRI Construction Materials GAF-012-02-02 ASTM D4977 11/06/01 Technologies, LLC GAF-020-02-0I ASTM D4977 02/01/02 GAF-082-02-0I ASTM D6083 05/07/06 GAF-084-02-01 ASTM D6083 05/09/06 GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01 Rev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-0I ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM CI289 10/22/12 GAF-417-02-01 ASTM CI289 05/28/13 GAF-464-02-01 ASTM CI289 10/22/12 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 IRT of S. FI. 02-005 TAS 114 01/18/02 02-014 TAS 114 03/22/02 Trinity I ERD G30250.02.10-3-R I ' ASTM D3909 11/26/12 G31360.03.10 ASTM D6I64 03/31/10 G33470.01.11 ASTM D6164 11/16/11 G34140.04.1 1-2 ASTM D6163 04/25/11 G34140.04.1 I-4 ASTM D6401 04/25/11 G34140.04.11-5 ASTM D4897 04/25/11 G34140.04. I 1-5-R 1 ASTM D4897 10/ 18/ 13 G40630.01.14-2A-I ASTM D6164 01/07/14 G43610.01.I4 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 08/13/07 G30250.02.10-3-R1 ASTM l )3909 11/26/12 MIAMI•DADE COUNTY APPROVED •• ••• . • • . • .. • •• • • •. ••. •• • • • • • • • • •�• • ••• • • • • • • •• • • • • • • • • • • • • • •. • • • . • • • • • • 000 000 • 000 • • • • 000 • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • • 000 • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 5 of 16 Membrane Type: BUR Deck Type l: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOut" Fire Barrier Coating, VersaShield®Fire Resistant Roof Deck Protection or (optional) Securock" Gypsum Fiber Roof Board. Base sheet: GAFGLAS4 480 Ultima' Base Sheet, Stratavent® Eliminatory" Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid SBS Heat -Weld" Smooth or Ruberoid® SBS Heat -Weld" 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® FlexPlym 6, GAFGLAS® 475 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximunt Design Pressure —45 psf. See General Limitation #7) GAFGLAS" Ply 4, GAFGLAS® FlexPlyr 6, GAFGLAS® 475 Base Sheet or any of above base sheets attached to deck with Drill-Tec" 412 Fastener or Drill-Tec" 414 and Drill- TecTM 3" Steel Plate, Drill-TecT' AccuTrac® Flat Plate or Drill-TecrM AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #7) MIAMI-DADE COUNTY APPROVED GAFGLAS" Flex Ply" 6. GAFGL,AS"' #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf See General Limitation #7) GAFGLAS® #80 Ultima" Base Sheet, Ruberoid°3'20, Ruberoid® Mop Smooth, base sheet attached to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf. See General Limitation #7) GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with Drill-TecT" 412 Fastener or Drill-Tec" 414 Fastener and Drill-TecT" 3" Steel Plate, Drill-TecT" AccuTrac®" Flat Plate or Drill-Tec" AccuTrac® Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #7) •• ••• • • • • • Y• Any of above Base sheets atched 1r ctect IfIrort I1nular ring shank nails and 3" inverted Drill-Tec " insulatiolf plaina:4aytepett:acing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. .• ••• •• • • • •• (Maximum Design Pressure —60 psf. See General Limitation #7) • ••• ••• • • • • • • • • • • • • • • • • • • • • • •• • • • • • • •• • • • • •• •• • • • • • • • , ••• ••• • NOA No.: 13-1022.15 Expiration Date: 11/04/18 ••• • • • • ••• • • Approval Date: 11/06/14 • • • •• ••• • • • •• Page 14 of 16 • •• •• • • • •• •• ••• • • • ••• • • 4 Fastening Options: (Continued) Ply Sheet: Cap Sheet: Surfacing: GAFGLAS'' #75 Base Sheet or any of above base sheets attached to deck with Drill-TecT" #12 Fastener or Drill-Tec'" #14 Fastener and Drill-Tec'" 3" Steel Plate, Drill-Tec'" AccuTrac® Flat Plate or Drill-Tec AccuTrac® Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf See General Limitation #7) One or more plies of GAFGLAS" Ply 4 or GAFGLAS(* #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (Optional) One ply of GAFGLAS`'' Mineral Surfaced Cap Sheet or GAFGLAS'`' EnergyCap''' BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: See Fastening Options MIAMI•DADE COUNTY APPROVED •• • • • • • • • • •• • • • • • • • •• • • • •• • • • •• • .•• • • • • • • • . • • . . • • • • • • . . • • • • • • . • • • •• • • • • •• •• • • • • • • • • • • • • • • • • • • . • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 • • • Approval Date: 11/06/14 • • • •• Page15of16 •• •• • • • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS ' Flex Ply'" 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum '/4" DensDeck"' Roof Board or '/2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size. shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. lino recovery hoard is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 Ibf.. as tested in compliance with Testing Application Standard lAS 105. If the fastener value. as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers. metal profile. and/or flashing termination designs shall conform to Roofing Application Standard RAS I 1 1 and applicable wind Toad requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation t.7.wiA•not;bdapNicpb3e)•• 10. All products listed herein shall have a quality assuraNrce a:cdre e%ith the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code'• ••• •• • • • •• • END OF THIS ACCEPTANCE • ••• ••• • • . •• • • •• •• • ••• • • • • •• •• •• • . • • •• •• • • • • •• •••• •• ••• ••• ••• •• •• • ••• ••• • MIAMI•DADE COUNTY APPROVED 000 • • • • 000 • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 00• • • • 0110 • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 16 of 16 • 1'1_I.R1306 - Roofing Systems Page 5of50 Incline: Incline: 1 Coating: — "TOPCOAT@ EnergyCote'" Elastomeric Coating" or "TOPCOAT@ MB Plus" or "TOPCOAT® 322 White Elastomeric Coating", applied at a rate of 2-gal./ 100-ft.2 7 Deck: C-15/3.' Incline: 1/2 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC. "DensDeck@ Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck@ DuraGuard'" Roofboard" or minimun-r ' -in. thick Untied States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6-in. from plywood deck joints. Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply #75 Base Sheet" or "GAFGLAS® #80 Ultirna'" Base Sheet", mechanically fastened. Ply Sheet: — One or two plies Type G1 "GAFGLAS® Ply 4" or "To -Ply 4" or "GAFGLAS® Flex Ply 6" or Type G2 "GAFGLAS® =75 Base Sheet" or "Tri-Ply .175 Base Sheet" or "GAFGLAS® #80 Ultima'" Base Sheet", fully adhered with hot roofing asphalt Cap Sheet: — IYPe G3 "GAFGLASCii; muter -al Surfaced Cap Sheet' nr "Tri-Plylg? Mineral Surfaced Cap Sheet", fully adhered .rni"`, hz); roofing asphalt. Coating: — -TOPCOAT® EnergyCote"' Elastomeric Coating" or 'TOPCOAT® MB Plus" or "i(SPCOAT@ 322 White Eiastome_nc Coating-, applied at a rate of 2-gal./100-ft.'. 18. Deck: NC Incline: 1 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or adhered with "LRF Adhesive M" or OMG Inc. "Olybond Fastening System", applied as a nominal 3/4-in. bead or "GAF 2-Part Roofing Adhesive', applied as a nominal 2W-in. bead with a maximum on -center spacing of 12-in. or any UL. Classified insulation adhesive, applied per the manufacturer's installation instructions Base Sheet: — One ply "GAFGLASciy Stralnvemt Eliminator- Venting Base Sheet", loose laid or Type G2 "GAFGLAS® =75 Base Sheet" or "Tn'Ply i:75 Base Sheet" or "GAFGLAS® #80 Ultimj Base Sheet", fully adhered with hot roofing asphalt. Ply Sheet: — One or two plies "Ruberoid® Mop Smooth o Ruberoid® Mop Smooih r 5' or Ruheroici® Mop Smooth Plus- or "Ruberoid® 20" or "Ruberoid® SBS Heat Weld 25", fully adhered with hot roofing asphalt. Membrane: — "GAFGLAS® Mineral Surfaced Cap Sheer or Tri-Ply® Mineral Surfaced Cap Sheetfully adhere; .x.-rh hot roor-cig asphalt. -"Coating: — "TOPCOAT@ EnergyCote'" Elastomeric Coating" or "TOPCOAT® MB Plus" or "TOPCCA-I@ 322 White Elastomeric Coati.-,g , applied at a rate of 2-gal./100-ft.2. 19. Deck: C-15/32 Insulation (optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Barrier Board: — Minimum vG-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard' or "DensDeck@ prime Roofboard" or "DensDeck® DuraGuard'" Roofboard" or minimum 1/4-in. thick Untied States Gypsum Co. -SECUROCK® Roof Board' (Type FRX-G) or "SECUROCK(T) Glass -Mat Roof Board" (type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier hoard products staggered •_+ minimum of 6-in. from plywood deck joints. Base Sheet: — One ply "GAFGLAS® Stratavent® Eliminator"' Venting Base Sheet", loose laid or Type G2 "GAFGLAS® e75 Base Sheet" or "Tri-Ply #75 Base Sheet" or "GAFGLAS® #80 Ultima'" Base Sheet", fully adhered with hot roofing asphalt. Ply Sheet: — One or two plies "Ruberoid® Mop Smooth" or "Ruberoid® Mop Smooth Plus" fully adhered with hot roofing asphalt Membrane: — "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® Mineral Surfaced Cap Sheet", fully adhered with hot roofing Coating: — "TOPCOAT@ EnergyCOte'" Elastomeric Coating" or "TOPCOAT@ MB Plus" or "TOPCOAT® 322 White Elastomeric Coating",asphalt. applied at a rate of 2-gal./100-ft.'. 20. Deck: C-15/32 Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or"Tri Ply® #75 Base Sheet" mechanically fastened. Insulation (Optional): — Any thickness or combination: perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or hot mopped or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet: — One or more plies "Ruberoid® 20" or "Ruberoid® SBS Heat Weld 25", mechanically fastened or fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 ' GAFGLASCt Mineral Surfaced Cap Sheet" or "Tri-Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS® EnergyCap BUR Mineral Surfaced Cap Sheet". Class B 1. Deck: C-15/32 Incline: 3'1:1 Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard"" Roofboard", minimum w-in. thick, orUintnilrrSta eslGypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), r Insulation (Optional): — One or more layers perlite c•Lo•,:Lfibe:or glas,i fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane•composit•: of wtodrfitxri.olyiisghcygnurate composite or phenolic, any thickness. Base Sheet: — Two or more plies Type GI "GAFGLASCri Ply 4'i it "i t.i'ly;y:c0o ,C� FGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Cap Sheet:�— Type G3C"GAFGLAS® Mineral ened or fully cSurfacwith led Cap Sheet"eor•'si•ri P® Mintraloiurfaced Cap Sheet" or "GAFGLAS® EnergyCap'" BUR Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 2. Deck: C•15/32 •Inilrncy•31/2 •••• ••• • • • • • • • • • • •• • • • Barrier Board (Optional): — One or more layer U.irgiisar.irfic /jest • :•LIT• tr •v)e•'K". Roofboard or DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard"" Roofboaro', min.nurn o-i•. thi:.•nr Unc• S1!1 Gypsuri Co."SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), minimum 1/4-in. thick. Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethar■er.Sm"osite,r woo41 f1)grip ilyisocyanurate composite or phenolic, any thickness. i• •• • • • • • • i ••• • • • •• •• ••• • • • ••• • • hltr,-//,-itlis,hf15t;ul.c0mic i-hin/XlVV/telrlj3latell;1ti1':A'l71FRAh1L/sh0wpage.html`'narrle="[... 9/30/2014