Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-17-2836 (2)
Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Permit NO. RF-11-17-2836 Permit Type: Roof Work Classification: Tile Permit Status: APPROVED Issue Date: 11/30/2017 Expiration: 05/29/2018 Parcel Number Applicant 86 NE 108 Street Miami Shores, FL 33161- 1121360110010 Block: Lot: MARY RODRIGUEZ Owner Information Address Phone CeII MARY RODRIGUEZ 86 NE 108 ST MIAMI SHORES FL 33161-7036 Contractor(s) MIAMI ROOFING SYSTEMS, INC Phone (305)754-5554 CeII Phone Valuation: Total Sq Feet: $ 19,000.00 2800 Type of Work: Re Roof Additional Info: RE -ROOF TILE TO TILE Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $11.40 $4.50 $3.00 $3.80 $300.00 $9.00 $15.20 $846.90 Pay Date Invoice # 11/30/2017 11/30/2017 Bond #: 3572 Pay Type RF-11-17-65783 Check #: 1229 Check #: 1228 Amt Paid Amt Due $ 796.90 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet , In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all • - . e.oing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. F ' ore, Iove-named contractor to do the work stated. ignature:'Owner / Applican ontractor / Agent November 30, 2017 Date Building Department Copy November 30, 2017 1 30 - -7 S ([ -33- / Miami Shores Village - --Building Department ' BUILDING PERMIT APPLICATION J:>m , • ‘,0 BUILDING 0 ELECTRIC,, ['PLUMBING El MECHANICAL 10050 N.C.2nd Avenue, Miami Shores, Florida 33138 ' --Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED 'NOV 3•0r1017, FBC 20AY Master Permit No. ps R-2.8SCIC) Sub Permit No. .). :;...,, .40 ROOFING . 0 (REvisioN El PUBLIC WORKS 0 CHANGE OF '0 CANEELCATION Ea'SHOP CONTRACTOR9r... / . DRAWINGS -,.):, 1. .. i.. ,--, •-, ).-,, t •A ,,f ,, . , #•# .-..' - • ,1 a# , i v. - el 1., e.... JOB ADDRESS: 86 NE 108 St '.1 Pt,:t , El EXTENSION .0 RENEWAL 1 ., City:. ,Miami Shores..., County: np: Dade- -Zip: :33 ti.,...8"•A .41,010. r • .., 1 .1 I1Folio/Parcel#: 36.71311,179.91.0 a • ) #7, Isiqte 8911cling Hjstorically,Desjgnated: Yes, al .0,•NOX., ;OccupancyType: rl'A Construction Type:'i 4fl W F!o0c129ne...,4:;.• — BFE: " s FFE: 1r4OT • 1.10:7:`,4,#) 1(") irctLe# OWNER: Name (Fee Simple Titleholder): Macy J Rodriguez Phone#: 86 NE ,108 St Address: 1 'I. „ • ,, 1{.14,• ,1 City: Miami ' ; • Florida State: 1r 1,- . Tenant/LesSee:Name: , Email: Zip: 33161 • •••,,, CONTRACTOR: Company Name: Miami Roofing Systems Adde-e-s- 660 NW 98 St • 0%0 phonet. I,. "i Phone#: (305) 754-5554 v •• City: Miami Qualifier Nam e:-I6nc61 Ojeda' State Certification or Registration #: CCC1330811 DESIGNER: Architect/Engineer: Address: State: Florida 1'1 - • 3 50 00i' 2c, 0.. .4.0_ Phone#: Certificate of Competency #: •). • # Phone#: , 7 - Urn n5 es4c1 Value of Work for this Permit: $ , 0 00 •.1, H q jt P. Type of Work: 2.eAdditi.on„,ahtsztign D New 1 Description of ork: i. Re-roofitile,io tile. 4 1,,,o; , , , .,,. I vti,," to ,- - 4 'r 6 ,0 .„, ,,I , *C- NO D.- • * t City: State: '" .1 Square/Linear Footage of Work: "1" 2600" 0 Repair/Replace Demolition A Ni.-Aiptg r t- • 0- • . tA7elfrf Zip: 0 Specify color of color thru tile: f 1 or 7 •thaf, •,•••• Ow' ""W'vt.tritm* Submittal Fee ,$ Permit Fee .$ CCF,$ Scanning Fee $ Radon Fee $ DBPR $ ' Technology Fee $ -- --Training/Education Fee $' Structural Reviews $ IN ' CO/CC $ Notary $ — —Double-Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) I • Bonding Company's•Name (if applicable) 10 M } dia t IT Bonding Company's Address City :,7 `I1#..+!lL 4.5 State -rt.', , t'!r lr ct. s r- .,r i , . t •i 1' Zip Mortgage Lender's Name (if applicable) '244 -. v'�0E) r'i.°i 1 'it'! I t1;1,-.43'4i:'.01 1s: 'fig` Mortgage Lendeer's Address)3 , City ;-_ A.,`I rT11 !State=.',t'i. Zip '' 1(fiGUe tdi tir►!'3G 1 due ifi t 1 A i.,Aq Y t k YA,A i Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior'to the issuanceniof a permit and thati all work will be perfdrn ed'to meet theistand`ards. of all lawsr`regulat ng construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS,,AIR CONDITIONERS, ETC --- r'%I,'•, ° ". ), ipuc t . i!y' .' ,j,., j riE:ff'Jtt li l a OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 18 LI r ` =`i II '2- • ,,rsuuA nOl. "WARNING TO OWNER: -YOUR FAILURE `TO RECORD A' -NOTICE OF -COMMENCEMENT -MAY RESULT- IN YOUR-PAYING:TWICE'FOR' IMPROVEMENTS TO YOUR -PROPERTY. —IF -YOU` INTEND TO OBTAIN''FINANCING, CONSULTWITH-YOUR LENDEWOR'AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." i(.11•1 bc-hiFilt: r? t.1'1112 .' M, ;•-' Jr t .trA Its Notice to Applicant: As a condition to the. issuance of a building permit with an estimated value exceeding.$2500; the' applicant must promise in good faith .that a copy of the notice of commencement and construction lien law brochure will be delivered to. the person whose property is subject to`dttachment. Also; a certified copy of the recorded 'noticed commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is,•issued._ In _theabsence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. i .�i•� Signature .OWNER or AGE t�'r .0 i The foregoing instrument was acknowledged before me this da �of , 20 by 114 .j (l t lil'z , who is personally known to me or who has produced~ +L as a t _ :Yr..;. __ identification and who did take an oath. y ,I.Identification and who did take an oath. `J,j•-ran ',u it.I ;P.i 5.j.yrXQ-t t` it.i1`Itr .._�_ . 4 'v ::9971 i ?i'I. Cti ,i•tti.A, i 9 IfnV NOTARY PUBLIC: t� ,rlo'd 1 , n I-, 'r �_ r-- .,-1.t�pcLt - r: '" 1-1 :1'ia V`iID }qyt Signature (r ,at.,i I *� .. The foregoing instrument was acknowledged before -me this day:of:,.�.F1l11 , 20 1—) , by Ti.7)`pftti CO -_ ., K rl i f='t i') V.11`_1'f_s'.^tlit `1e 3' 4t ybd4liC7"'7-' ..-t (_'•'tom[® 7j1 , who is agrsonally known to me or who has produced NOTARY UBLIC: Sign: Print:' Seal: ' at `; .. Notary Public IIU - omm ss11 .;gall.'•` ' My Comm. Exp tate of Florida _ APPROVED BY _ it 7-2020 Sign: Print Seal: as t A -n-.-, 9- ..,,7 4r,wsr[: 1...4 J'•i +q�.;" ****######################ii################################'####' 3' men s:i Plans Examiner _ - _ r Zoning -•3- rlt,;lcJu1i3-,.,•r .,,.a — t •.1'.rl 13-t r' 0° ai '011 14 11^'1711t3} (Revised02/24/2014) Structural Review Clerk '0,7• ..""UI, i Miami. Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33.138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building. Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: /C.Q & r % 5 (Lad Property Address: gb P £ 1 o3 S %- Date: it/Z 2fi Roofing Permit Number: Dear Building Official: I Ha -ex J (god r 5ve. .- certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) i�la r c� d v' Print Name t.) State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. day-f`m Sworn to and subscribed before Notary Public, Sate of Florida at MARIA M otary PQ fc - om s m Com EKs u When the just valuation of the structure for purpose of ad valorem taxation is equ. SFBC. Then you must provide a building application from a General Contractor for an $300,000.00, and the budding was not constructed with FBC nor a 1994 oofto Wall connection Hurricane Mitigation. Revised on 5/21/2009 Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY APPR ISER Summary Report Property Information Folio: 11-2136-011-0010 Property Address: 86 NE 108 ST Miami Shores, FL 33161-7036 Owner MARY J RODRIGUEZ Mailing Address 86 NE 108 ST MIAMI SHORES, FL 33161-7036 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds!Baths/Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 1,968 Sq.Ft Lot Size 9,225 Sq.Ft Year Built 1954 Assessment Information Year 2017 2016 2015 Land Value $198,007 $163,894 Building Value $137,087 $137,095 $137,103 XF Value $3,568 $3,605 $2,731 Market Value $371,293 $338,707 $303,728 Assessed Value $122,819 $120,293 $119,457 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $248,474 $218,414 $184,271 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 36 52 41 PB 52-33 DUNNINGS MIAMI SHORES EXT NO 7 LOT 1 BLK 210 LOT SIZE 75.000 X 123 OR 14340-4044 1189 1 Generated On : 11/22/2017 Taxable Value Information 2017 2016 2015 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $72,819 $70,293 $69,457 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $97,819 $95,293 $94,457 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $72,819 $70,293 $69,457 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $72,819 $70,293 $69,457 Sales Information Previous Sale Price OR Book- Page Qualification Description 10/01/2003 $0 21775- 0941 Sales which are disqualified as a result of examination of the deed 11/01/1989 $91,000 14340- 4044 Sales which are qualified 04/01/1988 $0 13678- 1618 Sales which are disqualified as a result of examination of the deed 06/01/1985 $75,000 12533- 2187 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: RECEIVE NOV 3 012017 9 1 1 1 1 1 1 1 1 1 92 .. Mortar/Adhesive Set Tiles Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) 2,$&D Total, (SF), . ' • • 1. Master Permit No. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida. Building Code 5th Edition (2014) h-Velocity Hurricane Zone Uniform Permit Application. Form. t i s• Section A (General Information) Process No. Contractors Name LtiCA-m; l - f /1aiJ •! g�jcf,.. M Job Address, � 7 - � E,. I CS g' ` „ c ' r » n �.t . ,:ROOF CATEGORY ❑ Low Slope 0 Mechanically Fastened Tile O Asphaltic Shingles 0 'Metal Panel/Shingles `O -Wood Shingles/Shakes [7 Prescriptive BUR-RAS 150, • ROOF TYPE 's' ,s ❑ New roof ❑ Repair D Maintenance litt, Reroofing 0 Retamtg —ROOF SYSTEM INFORMATION • '• • •.1 .••••c ' ,,)t,Section'B (Roof Plan) • • • • •' ' • • • • • • • • • • •1 Sketch Roof Plan: Illustrate all levels and sections; roof drains, scuppers,ty't overflow scuppers an'6l'f w drain?Rit signs of sections and levels, clearly identify dimensions of elevated pressure zones and locatlonoi parapets. • • • • '1 • • • • • • • J aT/P • �'ti 1 •• • :., - ,�.' `fin F l h / .. .. . r2 ''J rn .. r . x k ;, a l 14 �1t c0 Q cc 4S4. BY dl "1 O to Ili i Q rC 2 ZONING DEP7 II3LrIx3 EFiT U n C C 1 1 . PROVE I.V LL r 1 FLORIDA BUILDING CODE — BUILDING; 5th EDITION (2014) - •.••+• • •aay ••••i'• • 1• .••• • 1 1 1 I 1 1 1 1 1 1 1 1 1 tom.. 15.37 , Copyright to, or licensed: by,1CC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant` to Ltccnse ,1 Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL' ROOF ASSEMBLIES AND ROOFTOP STRUCTURES, +ter a° , 1{. . �..� • 'al ••••• , LSECTION 1625 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Sir r 4 1--).nt. p 12' cr 0.7>i '14I It .,i:; Mite : 3.. Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form ix3f.4yr .rrti - ..r 3 a tEy�;r -• INSTRUCTION PAGE ti 1 j l `L } "COMPLETE THE NECESSARY SECTIONS OF. THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the ri Peri iitAppUcaiion Form Attachments Required See List Below Low Slope Application,, ,• ., ; A;B,C 1,2,3,4,5,6,7 l Prescriptive BUR-RAS i150 • A,B;C r.; 4,5,6;7' • "' ' Asphaltic Shingles , ` r' ''A,B,D' " 1,2,4,5,6,7 Concrete or Clay Tile e` '_ : rA,B D,E 1,2,3,4,5,6,7 ...,` Metal Roofs r : ' •A,B,p, ' 1,2,3 4 5,6,7 . _ Wood.Shinglas and Shakes 14'_ '. 't. ;1 .01 r" A B D` ;, ° 1,2,4,5,6,7 Other -I , _-. , 1.-. As Applicable _ ''" -•- 1,2,3,4,5,6,7" ' • • • ••• •• ••••il• •••• • •• • • • •: • • • ••• 1 •• 1 t 1 1 1 i 1 i • • • 15.36 •••• • • •••• t,ATTACHMENTS:REQUIRED • • • is Fire Directory Listing Page ,_, • , .. ,A._ ,, -a ; . a` f, • • • _ • 1. • • From Product Approval: Front Page — Specific System Description' """ " 1 Specific System Limitations ....---•--• -- f -•General Limitations `• �' I .1 Applicable Detail Drawings 3. Design Calculationsper Chapter 16, or if appiicable;;RAS 127orRAS 128 4. Other'Componentof Product Approval , 5. Municipal Permit Application ( * 1 , L. 6. Owners Notification for Roofing Considerations (Reroofing Only) ;. 7. •Any Required Roof Testing/Calculation `Documentation _l t r INTERNATIONAL CODE COUNCIL' .46 i 46.1 1 FLORIDABUILDING CODE —BUILDING, 6th EDITION (2014)- a" i> *, Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezcr: Palacio on Jun 8 nse 2015 10:32:12 AM pursuant to Lice Agreement. No furthei reproductions authorized. - ;.._ ):r • 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Bullding,Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application,Form. 1 Section C (Low Slope Application) 1 Fill in specific roof assembly components and identify 1 manufacturer _ 1 (If a component Is not used, identify as "NA') 1 „ System Manufacturer: 1 Product Approval No.: 1 1 Design Wind Pressures, From RAS .128 or Calculations: 1 P1: P2: P3: 1 Max. Design. Pressure, from the specific product-- 1 approval system: ,1 1 1 "i 1 1 1 1 1 1 1 1 1 1 Deck: Type: Gauge/Thickness:. Slope: Anchor/Base Sheet & No. of PIy(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: 1 Top Insulation L Top Insulation Size an ness:. 1 1 Top Insulation Fastener/Bon •' g Mater 1 Base Sheet(s) & No. of Ply(s): 1 Base Sheet Fastener/Bonding Material: 1 Ply Sheet(s) & No. of Piy(s): 1 Ply Sheet Fastener/Bonding Material: Top Ply: 15.38 INTERNATIONAL CODE COUNCIL Top Ply Fastener/Bonding Material: Surfacing: 74 Fastener Spacing for Anchor/Base Sheet Attachment: Field: _' oc'@ Lap, # Rows @ " oc Perimeter: " oc @ Lap, # Rows @ " oc Comer: " oc @. Lap, #. Rows @ " oc Number of Fasteners Per Insulation Board: Field Perimeter Comer Illustrate Components Noted and Details as Applicable: 8 1 1 1 1 1 1 1 1 1 1 Woodblocking, Gutter, Edge Termination, Stripppingg Fi shing, 1 Continuous Cleat, Cant Strip, Base FlaBhing, Ci+urite shing,..1.... oping, tc. • • • . • Mean Roof` Height, Par�pgtHeight, la1 ▪ th lt'df Base, .;. n• Component Material, tempt, Fastener. 1 . , Fast= - Spacing or Submit Ill ufacturerrDet%ils'that;'1• • •: mply with RA and Chapter i 6._•. • . . • . : • ,�• • • • .. • • • • •. FT. •.•. • • • • • • • • • .I.••• • 1• • • • •y... • . • • . 1.... . . . Parapet Height Mean Roof Height 1 1 1 1 1 1 1. 1 1 1 1 1 1 1 1 1 1 FLORIDA BUILDING CODE — BUILDING 5th' EDITION (2014) 1 r Copyright to, or licensed by ICC (ALL RIGHTS RESERVED); accessed by Eliezcr Pellicle. on Jun 8; 2015 10:32:72 AM pursuant to Licenses Agreement. No further reproductions authorized. F k, •• • t FT. l •• , • • • • • • • • •• • • • 4 gr',;,ROOF.ASSEMBUES+AND ROOFTOP STRUCTURES Florida Building .Code t5th Edttion (2014),,g a High-Velociry-Hurricane Zone Uniform Permit Application Form t. I 1 Section D (Steep Sloped Roof System) 1 ;rfcIFc il0;i ::(.1.";: _ fl I, a r ' • Roof System; Manufacturer: r.� �.. 1 C.,- -Robe) n Prok c: , ' C L G, `ti •`.. ` . Notice of Acceptance Number. I'o$22- • 1•S1.4 , ,:. , ,,, .r s Minimum' Design Wind Pressures,'If Applicable(From'RAS 127 or Calculations): P1: -3a. 1. P1:-Lg. i _ pt.-too. '4- A: F. n Roof Slope:' 3 12 • • :•i- • • • • • •• "Deck Type: art , A Type Underlayment:' +•i Ridge Ventlatleit 'ro,„i • • LLi T • �.• .t,, t<. •• •• • • • • • • • • • • • • •• •• • • • •• • F• • - • • • UY if 30 . , insulaticn: I 14 Fire. Barrier: t .Fastener Type & Spacing: ,! •.1 13I. Mean Roof Height: ) 7 .. t Adhesive Type: S1F Type Cap Sheet:._ 7u Roof Covering: C T,i ie. 'tom,- Type & SizeDrip`.- • Edge: 'tx3 6'd. J t.'t..}. r. 1 1 1 I r FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) �} 15.39 Copyright licensed b.. ,.. (ALL RIGNIS RESERVED); accesied by E.• _ T. 's . . 71— ` uant to License e --•--- •- spurs t INTERNATIONAL CODE COUNCIL Agreement: No further reproductions authorized. - ' • 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) 1 1 High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either. Method 1 or 2. Compare the values for M, with the values from M,. If the M, values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations,Per RAS127" P13Q1 x9�a1?= to 3;'- Mg: E,44.=M,, 3, Product Approval Mr 243/- 3 (P244gJ 4, a 214= - Mg:6.44 = Mrz 11. S1 Product Approval Mr 2k- 3 (P3aC'o 14. all = 2.1.31) - Mg:4,q[ =• Ma 20. 90 Product Approval M, 2C . '21 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M, Mr required Moment Resistance* Mean Roof Height Roof Slope S5, 20r 25 30r ap< 2:12 34.4 36.5 38.2 39.7 42.2 . 3:12 32.2 34.4 36.0 37.4 • • • 39.8 • � • 4:12 30.4 32.2 33.8 35.1 `• '37.3 :. , 5:12 28.4 30.1 31.6 32.8 `� ••e•••• 30.5 •.•• • 34.9 32.4 • 6:12 26.4 28.0 29.4 7:12 24.4 25.9 27.1 28.2 -•..• 30.o .• • • • • • . •. • • • • • *Must be used in conjunction with a list of moment based tile systems endorsed by the Browarci bounty Board ofltuies and ' : • . Appeals. . • . • • • • • • For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If thgF' Values areoreatgr than og • equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. • • • • • Method "Uplift Based Tile Calculations PerRAS 127" "'. • • (P1:x L = x w: = ) - W: x cos e = Fr, Product Approval F' ' • (P2: x L _ = x w: _ ) - W: x cos e = FQ Product Approval= F' (P3: x L = x w: = ),- W: x cos & = F,o Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope ,0 . Job Site Aerodynamic Multiplier X Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mt Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight 1iy Product Approval. Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE- BUILDING, 5th EDITION (2014) Copyright :to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 6, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL • ••• • • • ••• • • • • • • • • • Listed Product Certificate • Certification No. L 17-0821.08 • • i • •• • • • •• • • • •• • • • • • •• • • • • • • • • •• Ref.; PrimeSource Building Products, Inc. (TX) 1321 Greenway Drive Irving, TX 75038 • MMAMIE COUNTY Miami -Dade County Department of Regulatory and Economic Resources 111105 S.W. 26 Street, Room 208 Miami, Florida 33175-2474 Tel (786) 315-2590 Fax (786) 315-2599 The Department of Regulatory and Economic Resources certifies that the above referenced manufacturer has submitted evidence to the Product Control Section to participate in its Listing Service Program. The scope of this certificate is limited to the corrosion -resistance of the product(s) listed herein. Ring Shank Coil Nails-GRCR19DADE, GRCR2CDADE, GRCR2DADE, GRCR3DADE, GRCR4DADE & GRCRSDADE (Less than 1000 hrs) Any product listed under this certificate may be subject to audits conducted by the Quality Assurance Unit of the Product Control Section. As part of the audit program, random samples, obtained from a supply house may be sent to a Miami -Dade County approved laboratory to ensure product conformity. Any complaint submitted to our office and supported by evidence will In investigated and may result in testing of the product. A listed product will not be tested more than twice for the same issue within the terms of the certification. HelA. Makar, P.E., M.S. Product Control Section Supervisor Product Control Section Certification Approval Date: 9/5/2017 fCertijicatio, Aire: 10/23/2022 Americo Segura, 'tYM Quality Assurance Lfnit Supervisor Product Control Section Miaml-0ade County's Department of Regulatory and Economic Resources reserves the right to revoke this certification for noncompliance Issues related to the Product Listing requirements and/or noncompliance Issues related to the manufacturer's quality assurance program. DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: i MIAMI-DADE COUNTY PRODUCT CONTROL SECTION . ,11.805 SW 26 Street, Room 208 Miami, Florida 33175:2474- T (786) 315-2590 F (786)1315-2599 `' a www.miamidade.eov/economy This NOA is -being 'issued under the applicable tules and:regulations governing the'use of construction materials. The ; ;documentation subirntted'has been reviewedand accepted by Miami -Dade Count] RER='Product Ccntrol Section to be used in Mia ni-Dade County and other areas where allowed by the Authority Having 3urisdiction •(AHJ). • This NOA shall not -be valid'aftef the' expirationd' ate stated below: The Miami -Dade County Product Control Section"" (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material'teited for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer,will incur.the expense of.such testing and the.AHJ may immediately revoke, modify, or,, ,; „" suspend the use of suchproduct,or material within their.jurisdictiom, RER reserves the right to revoke this v ceptance, if it is determined by Miami-Dade,County Product Control Section that this product or material ails to the • requirements of the applicable building code. • • . ' • • This product is' approved'as described'herein; and has been designed to comply with the FlorittrEuilding (A"del including theHigh VelocityHurricane'Zone'of the Florida BuildingCode. • •, • • ••• • • DESCRIPTION:= Polyglass Polystick Underlayments • • • • • • • • V. 7.<.it , ', , (0 Jz.• ;II ' i t '! r t., , ro r6„ •• i•• •••• LABELING: Each unit shall bear a permanent label with the manufacturer's name or 1ogopaitypstate and•following'' statement: "liarni=Darde County Product Control Approved", unless otherwise noted herein. 0 • • • • • RENEWAL of this NOA shall beconsidered after arenewal application'has been filed'and?here has $eeri'n changer' i • •• in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials; use, and/or manufacture of the product or'p`r`ocess. Misuse'ot' this NOA as an'endorsement of any product; for sales; •ad'vertising'or any other purposes shall'automatically terminate this NOAt` Failiiie'ta comply with any section- of this NOA shall' be cause for termination and `re"inoval of NOA. ADVERTISEMENT: The NOA..number preceded by the words Miami -Dade County, Florida, and -followed by the'expiration date may be displayed .in advertising literature. If any portion of the NOA is displayed, then it shall be done in•its entirety.- , .; -,; ttrt INSPECTION: A copy:of this entire NOA shall be provided to the, user by the manufacturer;or its distributors and shall be available for inspectionatthe Job site' atthe ""request of the Building Official. This NOA renews and `revises NOA No:15-0410.04 and consists of pages 1 through 8. r •. Ntj The submitted documentation was reviewed by Freddy Semino., PO4No. I?-)614.2'2 Expiration Date: 09/13/21_ Approval Date!`07/06/17 Page 1 of 8 • : Lik?Ition #2 • • „ ' roofing and roof tale underlayment. •:PAJXstick795T ax..6 &" x 3'3;3/8!' j,„TAS 103 and, ,, A rubberized asphalt self-adhering,.polyester reinforced, : •' afaeur i<i g • • : 60.mils thick AS3'M D 19 0 waterproo g mem1 rare. , ,Designed as; a..a roof'tile, t, • Location #t1 & • • RQOFINIIdCaMPoNEN,T APPROVAL a, r 1.. ., e 1 t Category: V.�' Roofing• Sub -Category 4 ' Underlayment, Material: t� SBS ,APP Self -Adhering Modified Bitumen , f�Y} PRODUCTS DESCRIPTION: l rodiuet ,Sc ]1' e E ))1 ii )1ti i 't' 3 e ri I/ '.i`f!I 1 ' 11110 f° .. i'' 11-1(1 r7i rtt,r.1)11 i?,) iltrid Iit.§- ' '°PPriY Test Dimensions Specification a f J1ir / .*1 t Z•tttry',crJti.i Productl f:=1 lip" 41 II.,. !, s Description Polystick IR-Xe 65' x 3'3 3/8" ASTM D 1970 A fine granular/sand top surface self -adhering, APP. LW' Mdriufaeturing r no'1� 'r� 65; x 3;,,, °1Fs.t' r , , ,j.;,, „ ,,polymerjmodified,-fiberglass,reinforced, bituminous Location #1 & #2 " 60 mils thick , tsheet material for use as an underlayment in sloped roof I I ,, + 1+, �;,, a S, , # �, ., f assemblies. Designed as,an ice,& rain shield. Polystick Dual Pro rtl ,,61'tx3'3 3/8" 11- ,I.,TAS 103.and',,., A rubberized asphalt self -adhering, glass-fiber/polyester ri . Manufacturing.rat ; Lt,1 ,6t1=' �ls thick 1.t, ,1STM l� 197€J-.1reinforced vvkte hoofing mbi e. Designed as Location #2 ' •i '. r i ; , t l l metal roofing and roof file underlayment. tyr. efl it • � j.f to ;`:; Jsfs},6"" ! �i . x,.j �., �;>, IYtn�+,: r•,•Y , .+r PolystickTile' Pre-" ' ! .61' x"3'33/8". S1103 arid'''. A rubberized asphalt'self-adheriiig;'glas's-fiber/polyeste'r# �r''�' "• r: '' "� '- F thick " ASTM'D 1970't=reinforced waterproofing membrane. Designed a'a metal Ma'nufactu�ttg „- .1 • • • •• •••• •• •• •••• ••PSlystick'LUZZ •.32:140" x 3'33/8" ,1'rO.r'tr !° .f;r`:;1'� t!_' amaerlayment. Pry fi ly; a ' .7�,••Sy.J.inQi ,31. '+� /� FI✓ I It "Le ri TAS 103 and A rubberized'- asphalt waterproofing membrane, glass- ':Meniufacturtng• • • • •130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface • •:4 . tion #24 • ed or use as a tile roof underla Ym •' Pol stick'>'�i;his • (Surface P=ir .trig) Manufacturing Location # 1 & #2 r. Polystick MTS, Manufacturing Location #2 • • • • C ,• esi ent. 'Q( .e •2t' tr.11 •'t.., .t.� r. #cs r:...T; ;( tI dr.. is" f- 1'' ' 1-, r- N f.: ' l'f �4 i - • • • 65; x 3'33/8" 80 mils thick i #lrrxa"- f,' • I t . �; fi a';1 '1 .mr 65'8"1 xt3t3_s /g'"t' • • 60.mils thick M Po.13+stick MTS Phis i '65'.8" `ic 3'3 r r ,�t; e TAS`I03=r' ', 1, • trl% t' s t,1 i." 60 mils-thicic-1 fY i t . _ aft Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 MIAMI-DADE COUNTY APPROVED "1 .t'' „• .� r �1 ttfrr Hr/1 ,S 32'10" x 3'3 %" -" rrItt` TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester ASTM D,197.0.•7reinforced waterproofing membrane._ Designed as a metal Il, avr 1.„.r;01.i`rpofti.,intirooftile,Onderlaayinent rt 1 '1r., 4, rs ej, [i 14 h . ,'"i•' ,rl ft te:. 1 llj rr / f #/ 1,: ft. If kf°l't.. TAS 103 ; .. A homogeneous,,rubberized asphalt`waterproo ing , ; ,„ membrane, glass fiber reinforced with polyolefjnic film the,upper surface for#,use ,as on underlayment4formetal roofing, roof tile, slate tiles and shingle underlayment. ,ii : r f,'' S / ' 'F �-',. t tf:..�'- 'r'St F ous rambborized asphalt wawlploofing' r A ti gone membrane, glass fitier'reinforced with polyolefinicfilm`1 on the upper surface for use'as'an underlayment for"nietal roofing, roof tile, slate tiles and shingle underlayment. .r r `1: t - • } .. ltkt�.. aF it TAS 103.and , Polyester reinforced, SBS modified bitumen membrane ASTM D 6164 with a sanded back face and a granule top surface. For 2 13• J4; , use in roof tile;underlayment systems: ' ,. , ,• `ar. 11' ; I.t) ...i,.*•71#'.' d >NOA'No •.:-.17-0614.22 • Expiration Date 09/13/21 Approval Date: 07/06%17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL r;y ;.: ; EVIDENCE SUBMITTED . ' Test Agency is ; `Test Identifier' Trinity l ERD i ; ; TI i; PRI Asphalt Technologies Momentum Technologies, Inc. r, • LABELING: P 10870.09.08-R1 P10870.04.09 4;P33360A6.10, , P33370.03:11,, P33370.04.11 P36900.09.11 1337300.10.11 P40390:08:12-2 P37590.07.13-1 P45270.05.14 P46520.10.14, P44360.10.14 P43290.10.14 ' PLYG=SC 1`01'30.06:16-3 PLYG-10130.06.16.1 PUSA-035-02-01 ' PUSA-055-02-02 PUSA-089-02-01 Test Naijne/Repott. TAS1103' ' TAS 103/ASTM D4798 & G155 r. ; r,. ASTM D1970;t, ASTM D 1623 "1:4ASg103%ASTIVI-D4798 & G155 TAS 110/ASTM D4798 & D1970 ASTM'D 1623 , , ry'ASTM D6164 TAS' 103, TAS 110 & ASTM D 1623 ASTM D 1623 ; TAS 103 &TAS 110 ASTM D`1970 & TAS 110 TAS `103 & TAS 1.10 • Date' n = 12/04/08 , , 04/13/09 07/01/10 f, 03/02/11 04/26/11 09/617 i'iP" ° 10/19/11 08/07/12 107/02/1'35 ` '05/12/14 ,1), 4 10/03/14 10/07/ 14,E • 1.0/17/14 :"Ve//27/16' 4 ASTM D>19764e, TAS•1•10 • :.. JV I27/16. •, • • TAS 103- . • • • •. TAS 103/ASTM D4798 &•6155 . . JX20H7A TAS 103/ASTM D4798,4.Q155 RX14E8A !r, TAS 103/ASTM D4798:& i155 i; DX23D8B ,, r• { TAS,103/ASTM,D4798•,& G155 DX23D;8r A TAS 103/ASTMrD498 so. „ • r . . .09/29/06'`Y • . • .11/ 10/0' • • • 07/06/09 •: • •, ..•- -• •••04//01/08 .• n;*t 1i11/09/09 ' * • • z :1':'02/18/ l q ;•;•01!1g/lg„ • 1. All membranes or packaging, shall bear,the imprintor identifiable marking, of, the manufacturer's name or logo; city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below.! rt, ; ► s k ,rrr t APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No`::17=0614:22 Expiration Date- Og/13/21. Approvat Date:' 07/06l17': Page 3 of 8 • • • • INSTALLATION PROCEDURES Deck Type 1: Deck Description: System Type E(1): Anchor/Base Sheet: Fastening:;. i 1.. Membrane: i r•' , 4`i1 Surfacing: t pAitt'3,rS:II'"1"' Yet, EV, tl ,sil 11sS11 1 Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically,'fastened to`deck,+membrane adhered One or more plies of ASTM D 226 Type Il;or ASTM D 2626. Per FBC'1.518:2 & 1518.4 Nails and'tin taps •12"grid, 6" o.c. at a minimum 4" head;lap. (for': >:+base;sheetonly) ►1t, F`if�DU+ t14 Poly'stick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Po1y4_tick TU Plus, Polystick MTS`or I'olystick MTS Plus, self -adhered. ;. ? :,SeeGeneral Limitations Below. r I 4,0 0. rQ at-,1 Deck Type 1: ,i Deck Description: r System Type E(2): AnchorBBase Sheet: tD i • •. iggrtening. , • • • • •'ffeinbrane:• • • • gBalyfl; • • • • • Wood, •non -insulated rl4iin 19t32"ply od.or.wo6d plankt c, Anchor sheet mechanically fastened to deck,Tembrane adhered /} DOne`or more plies of ASTM D 226 Type { iII or ASTM D 2626. !t'�+pi.�'•"tin i.{ ttu;y� 1.`1 • Per FBC 1518.2 & 1518.4 Nails and timcaps112;^grid,' o.c. at a minimum 4" head lap. (for ,',•base' sheet only) •:Lfastoflex:S6,G, hot asphalt applied ".1, ,1q • • Ace Ge-6ral Limitations. Bel �,: �.t, (' /• ..' • • t. Tt, • • •meek Type If • • • • • Wood non insulated ti • ;]2c1S,kDescriptipn: ' M=n.>'19/32' plywood or wood plank t, , :11, ' < rl • Sysiem Tyype )� f3): -t• •• • Base su sheet mechanical ly fastened to deck, bsequent cap membrane self- adhered. • Anchor/1 Sheet:' • ` One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: PeeFBC 1518.2`& 1,5I8:4•Nails andtin caps 12" grid; 6" o.c. at a minimum 4"head lap. (for base sheet only) :'),`i d ixt.t rii.' '1Polystick MTS'Plus 'self -adhered with minimum 3" horizontal laps and ininimum"'r6"'' - ui,•„ t vertical'lap'or c I. n;3r ' ( ' 'rI ; ' S,1;, . 'r.r. ;ri, bill /: i i _ i i ^!7,' !,i Il: r'°" .' 4,, t 1' 9 r"rj , i; . '''' If „ r-., ; `'"L' 1 . 1 ,,i ) ' C1-err'._ !;. Polystick TU Plus, self -adhered. - ' a slr,tlda t 'LL,C,?/- 11'1 Ply Sheet:^ i' Membrane: Surfacing: ..,11 1•! See General Limitations Below. r; Jlal ./',e, . t1tA r1 D t rr W /PI 1, 431i"351i l(,l'1Ss : aietri °i }lrIl,,�j rZ rlr ti, . ;qr. +'i i' DIt! f"rf:l, t.•. 1 ie.; 5r,t ToT. rt^itir4,11q , kY'. I a'lj r Llf 9 14ryirJiu ! °j t' VC,I< i. D }11.1(1 # •. ri at! It; nip', t NOA No.: • 17-0614.22 Expiration Date:. 09/13/21 Approval Dater 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: .,T, .J .• !i' , .": , - J , a• , 5fJ .J i .1' - L!., ,rz: t, tr'1, t ,,, .. 1. All nails in the deck shall be carefully checked for protruding heads., Re -fasten any, loose deck.panels; and sweep,the,,deck thoroughlyto,re move any dust and debris prior to application je il.'1 . ''s i!, „: • .1 ,i4li.1 2. Place the underlayment over metal drip edge in accordance with RAS 111. . 3. Place the first course of membrane parallel to'theeave, rollingthe'riiembrane to 'Obtain maximum contact. Remove th'e'release'film as "the membrane`israpplied !'AllTside'laps'shall be a minimum"of 3" and end laps shall be a minmum; of 6°" Roll the membrane into, place afterremoving the release strip. Vertical strapping"of the roof with Polystickis acceptable. Membrane'shall befbacknailed' in accordance with' applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling'the` '' `...,; > membrane.from the center:outward"in=both directions., ,,`s,rrv:, , ,fi. .:'.: 'a:,f,>/ r../ 1' 5. For ridge applications, center the membrane and roll from the center outward in lioth directions. 6. , x•-;Roll or,broom the entire memsu brane rface so ,toPhavefull;contact- With ,the_ surface,:giving special attention ,;.to lap areas. r l _ . - as 01 . a', / s «t 7. Flashivent pipes, stacks, chimneys and penetrations in:compliance with Roof Assembly current Product Control Notice of Acceptance: - J1a1 pit` J rj. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The,flashing tape shall be pressed in place and formed around the protrusion to -ensure a tight fit. A second layer o£Polystick s11a11 be • applied over the underlayment. • .•' 7 • • GENERAL' LIMITATIONS:, •' >t • 1. Fire classification is not part of this acceptance. ii> I;• • • ;,t, 3,,." i".., • •••• 2. Polystick Dual Pro, Polystick Tile. Pro, Polystick TU Plus, Polystick MTS and PgiyStick MTS RJva may be,. •: • used in -asphaltic shingles,, wood shakes;and shingles; non-structural metal roofing,,roof kilo systems and quarry • . slate roof assemblies. - . • • Polystick TU P may be used in all the previous assemblies listed except,metal:roofing: ,., .',•.t;, • •: ,y 1, • Polystick IR-Xe may be used in all the previous assemblies listed except metal roofingand roof tilesy�ttms. • • Polystick,TU Max may be .used in non-structural metal roofing ;and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be:in compliance with applicable building code. 4. Polystick,IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU,P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a'smooth, clean and dry surface. The deck shall be free of irregularities. .,,y `` - , - •- 5. Polystick Iit-Xer Polystick Dual: Pro, Polystick Tile Pre, Polystick TU Max;, Polystick TU,P;P©lystiek TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a prey-existii g roof membrane` as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporaryroof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days -MTS IR Xe Elastoflex S6 G 1 'TU te I' Plus' TU P 'T1le`Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 t180L 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and r NOA No I74161 t.22 Expiration Date: 09/13/21 Approval Date: GT/06AT Page 5 of 8 Rule 61G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall betas set for 1 in'the roof tilet 1manufacturer'S Notice •of Acceptance: 11 J4l a *f IIX..i ij'}''r11 r;? , =."1 1tt t'� ,.7:i�. `1 aF! tl ' ,tfi. 'td Polystick Tile Pro, Polystick'TU Max; Polystick TU•Plu"s'or Elastoflex'S6 G'May be iised'in'botteadhesive set -and mecl>ariically 1'astened'roof tile'applications:. + J I } F .ram.. q 111 IL Li 'r •fr-11.” Polystick Dual,Pro. is limited to mechanically fastened,roof tileapplications. r• ,, Polystick MTS' and. Polystick MTS Plus are limited.to mechanicallylfastenediwith;the_limitations outlined in . Section 9. f, ,'-,rt 4• Y >t 4 E •• J . . }..Polystck;TU:P, maybe used in,mechariicallyfastened rooftile, applications;,with,the exception -AI' mortar ,set tile applications. t., , � . _ 1 , 4111$i' 1 'ltrr,Jrt' ri. r „r L,f rt�•u {'SYi. ,f)t(f, gfsf',rri' tf ^'L'�� r'E, tC it iif .-Hlf!r`'F �+ 1 [Jrt,y ! rc•�i+ f) ,,- 9. When loading roof tiles on roof tile underlayment for (direct-to'deck) tile assemblies; the maximum' roof slope shall be as fellciws See :Table BelovFr + lJ �!i' , r ;1 _ �,� . .• ' , .. ,. � .. .. ... - .,.. )i}il' ., r7} � t'1 l,ri.r? • • • • • • • iJO Tile't r1 Profile r tr.)`, ,t,c,tt ' i Polystick,';' = MTS ;t1,_AAA, , O.,'. - Elastdflex- S6 G r, ..,r' , _, rPolystick •TU`Plus„ ' ` TU P, Tile -Pro, 21,7:,.rDual'Pro ii r.... =Polystick1' TU Max .t1 _Ali,. it -'•it )'Polystick 1 MTS Plus .,c_ ., 11t t- . •' Ji-'System' (E3) •MTS Plus•with ar ,..TU Plus Flat Tile Prohibited .1 i 41.1i,.. ;, .without batterns 4:12 :: 41-4 /id i. YS 6:12 •1 . `.l ',' t t11 v 1:'l1- JJ".if 6:12 t to . J 5:12 - '1' ' rii'iSia i , 't• " `6:12' 1:e..':. y:1- 1.!. •Profiled;:{ I•'',_Priahibitod ' �, -: • • •• •• withQui 1'rttens Tile • • ow) .4:12 1i" r..l1J - 1`6:12'` `'2s:T., Y'l^i6,1:2i,.,. t, r,-,.f"4'12 Jfi)., ..Fl:t. , rr' -612. �i I ,1 jj OW- t • • • The above slopaliir nations can be exceeded only by using battens in accordance with the Approved Tile System, ▪ • Ndtice bf Accejitnnee and applicable Florida Building Code requirements. When battens are required, they shall • • be utilized durinfg'tdading and installation of tiles. a'J i' jrt' ))2 r="1' ''' V' 'r frit ft'..' liar!' a `J-' •••• • : • •149s '•Carei9kould.be,taktiii:during the loading procedure to keep"foot ti-affieto'a�miniuma i� nd'tdfdropping of • • (I tile directly on; ulderlayment. Refer to Polyglass' Tile, loading-detai1 below'fof loading,p'r`oceduretwo tiles laid iendictilar titslope followed by a maximum four, tile -stack parallel to•tpheslape for` . total of 6tiles — for • • • ••• • all underlaymonts except Polystick'MTS -which shall beloaded'onto 1iattens' tf j. '' 'r •, , f t `i ' ILI) t'`q • ;tr F 1 .I, v at r,i ,1, el.iif i!'i•.+;• •T .,,1y t•Ji�,. rt f,• 1i�il S zt 7 e ,�'� :t*'J J, r fi,`, ).r f; ;!'t,flt_ ' , f d f }i t " t � ix�' 1 > lt3`P x AMP Y P if ><t:ii` .S 1 i_ r11,kr r lt ) ;;fulJlia:�T 1tl,Cii,1'l „dJ 1"7 1 ry r•f rii .'tr ,rri 7' (fi .t (6 Max. Per Stack) l+ 1 it )11 rltt i .i 11 1 1,1 7' 411;12,. , SIi�J ._?.I., )to') ,r,rq t F3'.v 3"'t., 111 ! 1 fril ,1'21-1t ►)i:`; :1 Ji rt t1i -us .Y t lip tJi r.?lfl i t" T„ llf )IItJ 'l ty tr1llc� • ri ;fa', 1, .t 'i- i} ..f,;ilrl ;i!} .'tF,i i-irr},' 11 I. "Sr�ir � ?lilt('.:M.- ,i 1.11,/ r ':Sf' 'Mil arfl.)JTrtit .:'i i7)1 iy, it. 1 Jf' ;Ga' i0 `.;(,., r E I f r t kr � f v,> -41/ at"t t) ( ) ) fix ,r { f•' r:11 i'1)f11 f'✓ r.JMrt t:i' Moro-4' t 1 )fir. `11 it.'hi e1iil;f J ,3.ri i 11J:f1 .te( %.,'1; ,Jr!f,a .1 'NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. ' Refer"to`' prepared roofing system Product Control Notice of Acceptance for listed approval of this product with ° t a f. r., + . ,i, �.. Y f. specific prepared' roofing products. `Polystick`IR-Xe, PolystickDual'Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU PIu's;Po lysticleMTS,tPolystick MTS Plus'or El'as`toflex S6'Grmay'be used with anyapproved roof covering Notice of Acceptance listing Polystick 'IR'Xe; Polystick.Dual Pro, t Polystick Tile Pro; Polystick TU Max, Polystick.TUP;,Polystick TUPlus, Polystick MTS, Polystick'MTS Plus or Elastotlex S6 G as a component part of an,assemlily'imthe'Notice of Acceptance. ' r r If .Polystick IR-Xe„ Polystick Dual P,ro„ Polystick'File Pro, Polystick T E7 Max,. Po ystick TU P, Polystick -1 TU Plus., Polystick MTS, Polystick MTS Pies, or. Elastoflex S6 G are not listed ;a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided -I, " ' that'arro riae'documentation isProvidedto detail com atibilitY ofthe `Prdd�uct. s{ and fire • „• testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK 1VIEMBRANESr' PLEASE. CHECK WITH LOCAL: EUILDING CODES REGARDING,LIMITATION°S OF,SPECIFIC APPLICATIONS: LOCAL' CODES MAY, SUPERSEDE POLYGLASS REQUIREMENTS AND1RECOMMENDATIONS: 1. Polyglass does accept the direct application of Polystick underlayment membranes to + vooa :decks.' Instillers are • • cautioned to refer to applicable local building codes prior to direct deck installation to i vurp this tS aCeeptable. • Please also refer to applicable Product Data Sheets of the corresponding products. • 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage ede•s� tin as peg Polyglass. Back Nailing Guide. Nails shall be, 11 gauge ringshank type, applied with a•nminimum 15.7 metal it ;,as• • required in Miami -Dade County or simplex type nail as otherwise allowable in other rcgt at a i'hininaiim rats of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area,.area para clavar" on • • the face of membrane, with the above stated nails and/or disks. The head lap membrane is to.cover,ivAva beilig • • • • back -nailed. (Please refer to applicable local building codes prior to installation.) •• •. • •. • .. . •.. • 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. •: 4. All fabric over fabric; and granule over granule end "laps, 'Shall have ;a 6" wide, uniform layer of Polyglass Polyplus 55 Premium` Modified Flashing Cement, Polyglass Polyplus 50Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes. of 7"112" or greater. It issuggested thaton pitch/slopes in excess of 6,'/ '/12,", precautions, should .be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB-Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: •.17-0614.22 Expiration Date:': 09/13/21 Approval Date: O7/06/17 - Page 7 of 8 • • • • • • • • •• 10. All self -adhered membranes must be rolled to ensure Mfull contact with approved substrates.. Polyglass requires al {minimu414,1; of 40,1bs for.arweighted roller for.the rolling of the field membrane. Hand rollersareacceptable for rolling f patches or, small areas ,of the roof. ,Brooming maybe. used where slope prohibits rolling., , • { '..tt•3-.trt.<-e ley tot t ► A`': .t., lir: :it. .t .: # i' . /it.,., lt. J r v.i : t.Y t' 1... ►. . . it rK<>� `}� 11144 11• All 'appr-Dyed.subs!trates'sh©,ild'be dry?'ciean:>and properly: prep&ed, before,any applicatioin;ofPol "stick, { u ±l membranes commences:r'An approved substrate;technical5buIletin canlbe furnished{upon request. It'is> recommended to refer to applicable building codesprior to installation to•verify acceptable"substrates. ►r*1`tt 12.-'The •-Pol• `lass Miami -Dade Notice'of Acce tance (NOA)a` proval for Poly• stick membranes can be furnished -"The-Polyglass P ! , PP t r Polystick 7 [r ir3.�rv�;<7'1 it+:"i r'upori•request by our Techiucal'Services'D'eparti lent by ca111ng'1 (800)'894-4563: < I. r", .F 4 r "".,tit 16' * (tt, t t Y rt, t}3[" ' ( sbr (u"7U'r 5 11 tt' 1 i.i/ { •tt 1:, `i- 1t►tt; J ;p1).t4i,' 13. Questions in regardsito the rapplication of Polyglass products should be directedlto our=Technical Services,l Department at 1 (800) 8944 4-4563. ` I wa;t1.J3 14. Polyglass:reco ntr e ids:that iapplrcatars falls lv goad:,rt ofirig gr fioes .and`applicable procadures as outlined by the National RoofingpO Contractors Association (NRCA). t t $: ...'F• 1.19.�7"?#'. 7i. r. ie 1 �.<„ _, # ?:. �R•t ,!i'ik '!-ti.0 al, It +43 1{'t I( *Z1ti!i1", 41, 1, f"f p a.re/'KO PLEASE CHECK WITH LOCAL' BUILDING CODES REGARDING LIMITATIONS. OF SPECIFIC APPLICATIONS. LOCAL°CODES MAY SUPERSEDE'POLYGUASS REQUIREMENTS AND!RECOMMENDATIONS: • t{r '� tr. iii.i1 • f 't• 1,•y,• •'r3 :.7 11 h' a. (t 1z, _YJ�� e''b', 1, 1.' 1t ri • • • • END OF``THIS ACCEPTANCE • '.r ;rt., N �.t + ;tt .1 t41.10 - t - ) s. .- 4 ,. !i J.tl'•l, "f t,hg ' 7 ). (. u _ it;.y • ".• - 1 i ( 7.i i...1iJ `� 1tIF3 tot !i' ''! !.,1j' ` ! • ..t'tt'171i7 tti'1:110' .'ert7:' ler 'it td, J:1 •? t;(1 i-11)0in '/%. • • ••••• r• i : i �`• 1 • �� 7 r •! 01 ter ?-' r•.- s •!' `'1: `a • 'r'El �'.fi •`1 F,7 ': 1 " a) ')N ''rt41 7, `1• r%r„rr t ro • • ra t - . t `' ,,'r f ".rim 1 f r t: • • i� :�" �'i`^ • i 7t:,C; "3t,�:'t3a • , S' % ` 1{ (: (. 31T,'r`1 . ( C'f: t J : rlJ:ai t :1. ` T1 { • • a5, r •1 _ t WOO ,•••• !..ft. ;' tt. ,I t;,}jI` T rii 1;'}l ri A J 1 t:f% -„rr' 1 , tl;ai' 14'1't • ty •• r:• t I •, • 1 • JI`<'1,t1; 1 fP` ').>_: i.i iri<.ti.s `!., bill, ?1!!il .1.12! u" .. 1 ': t` C! l•` 1 q • • • • i '• i'� t ).�l • ll r'J;x s� 1 t ; , t: ) ` • • • • • (IS.It, tt. n• tr I:irS -iri J s"illsl4tJ'.j i.l;,:il1 r'1-"11;.�11 `.li> t•)1 " Il It i.rtll i j1.�f • • • i • •• .111.11 t'1.7''cF:' 1,n'- Lfi:J 113:'tl•t.. r•,.,'t'-fj D1 41.,-)'rt,it:.,..1f,'11s:.,, }� Y ., r t. t, f'. I •. I r . i, ,3. 'l . 'r ! r ., r-5:tJit.Jn., 'i. 3 1-05 •1 ...It. , > 'r' •1 7 i)• eltt.1 .I�7t'.) <r• ;Rk..0 ,iii,i'1J .1._7 It!t'. t J<aii 1 '.7„r..1 . ',rt-_,.,. i . *, q: 1 t 7 :.I1 l: , off.), t t ir.. .e9. .1rf`%.11_1 } f ..'/,/ 1Ja.,t1'1 J. ., 111 ji,' J, 1 ,'.1.l •..i +e `�f _ ;!1t• Vi ,)1 � ";;1 }t i. r r 'iJ .T35vi;'.� 1 �it�. , t.I, e' 1 .t �.: 't 'r� .�1 :.J_tel i ctl":: .ir�`. �: � ,I.' i'ltL t101 .:di (Jt i 'a1 't3'"':rry,r1.1.1, t ' 1 7t•,1 1.1 r?Y.: " )1 t1:? 1L"µ 4, Tilt;l.: till 4 0 1• u � :'J,t ` it. . : t 41t` Lri- ,i:011.,ttr,..1 t._tiri*,t t't ' L •s`.,.4i' `..f: ',[,7 1 :id ! wrfl .., (t •r ..t„, rl,t- ,11 t:1 t1 •' jJ.3,r1 f:')t, r Al) ''.rCTJ7>x- t1".)1Fe .111 T n t) 1' :', ? Jts11 ' ' -loth '1 (S[ttJ.it J'.tJ? '' ., r 0'1 i•f.? .i11 yit_ T';111,,'11 7.,.i3"1, .of tF' lit.'! It Ji:"'litilly. .ir C r J •37: "1' {:wti: '1){.1 ftl,..'lE 1` ,riftt''tfi Fit ;. =J'1.r�sili,l. r1:411J1'? ('r* .• .L•r trltril{ i 1 tl tort , ir(r n xd 711 :tr7' ,1.i1CU 1t1�1 4 'TrL kN1i 't1 i i''f")!#Tir`3.:1 JCi r).i r.' ' 7r:i 1t {'ir., t1i,'(1 t. r..7. _. !'A.. �.>r.. lx'i�F...l .'r. 3 4 .7 i( i)' 7."t, t•, :."ll. yilJ ill r+Al 9•'ltle. , 7 t,'i, et• 1 ''t r+r3•�S:{) I ... S: Ii •l ••t..1 . .1r , )31; •,t!T 'J fir. 1 t,. tft,)'t r.1 ,1hr 31'lr'�, .la t1 10 y e 4 rli 1 115 .'7 111 ti:,1 111 Tt' ?1 )71.1; io01tj t(. i1 )t1, `' 1p 01L1.411111rr1 t !� IILI{i 11_.,?::si1 'At 1Ct ?"'+:1 ;.t, C7 9-0) 77:i 1`rvft :rn rt3 151i Ain 1 ?.1 it"a i.. t %' t-t 1t ,NOA No.:17-0614.22 Expiration`Date 09/13/21 Approval Dater 07/06/17 Page 8 of 8 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL: 33065' SCOPE: e, MIAMI-DADE COUNTY a " PRODUCT CONTROL SECTION ' 11805 SW 26 Streets Room 208 Miami, Florida 33175-247,4 T (786)315-2590 F=(786)315-2599 e , : ,a t? www.miamidade.eov/economy tx This NOA is being issued under the applicable rules and regulations governing the use of construction materials..The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami DadeCounty;and other areas where :allowed by_ the Authority iawing Jurisdiction (AHJ).. . . �s s This NOA shall"not be.palid after the expiration date stated below. The Miami-Dade'County Product Control Section (In Miami Dade -County) an`d/or"the AHJ (in areas other than -Miami Dade County)'reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the niariufacturer`will incur the expense of such testing and the AHJ may immediately revoke, modify, or ltisZad the'use of such product or material within their jurisdiction. RER reserves the right to revoke this aceeptari Vie, ''if it is • • determined by Miami -Dade County Product Control Section that this product or material fans to 1eet't12e tegdirenierii`s .: • of the applicable building code. , .t, ru This product is approved as described herein, and has been designed to comply with rlete'P(priida JuiJdYig Code • including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • • • • • DESCRIPTION: ICP-Adhesives Polyset®AH-160 - — 7 $! t i.1.•' s •• _ /°•, 6 •',t!?.B LABELING: Eachiunit shall bear a permanent label with -the manufacturer's name:or.'logD, •csty'state;atld fpllowi2i • • •: statement "Miami=Dade"County Product' Controi:Approved' unless' otherwise rioted herein. ' . '..' .:, .. .. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product; for sales, advertising or any.other,purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause -fo termination and removal of NOA. -il i. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done • in its entirety. r;-; INSPECTION: A copy of this entire NOA shall be provide I'to the user by the manufacturer or' it's distributors'"and shall be_ available. for inspection atthe job'site at the request of the Building Official. This ls.10A,renews NOA 16.0315 01;•and'oonsists. of pages .1 through 11. The submitted documentation was reviewed by Alex Tigera. a a, 441 • • • ''NOA No 17-032 17 Expiration Daie: 05/10/22 ApprovarDate: 04/27/i7 Page 1 of 11 •• •• • • • • • • •••30& 100••••• • • • • • • • •• ROOFING -i.i E I. r Category: Stib Catego 'Materials: if t1.1 SCOPE: COMPONENT APPROVAL: '1 y. r i r rV •R fe - ''' ' ' Roofing ' 1` Roof tile adhesive ry: ,; Polyurethane ../. Jris'•a I' {Jr tti a„'i it'30,i)../A it, # '.1'r ;)1'i't 1TLi 11 l t. 1 ?i /1 E1_ttl..EL1 )' >' fr.''? {i it+,1F ` r } sl. r r E 1- This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicablet�v building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof title systems using ICP '(� � ) 1 Adhegives`Poly'sete AH2160.' ' 1 '1'1.'1- /EIS, ,.r` r+:,t� l,r .. , t,J .'Slrr�. �itl, �.it 7. br, 1,111 .1 ‘'i 1< a't. t P r fw+ } t 1 -S `r'1• J'>•1 - .� r.l. ' :.'�,i tr, lf'r," 1 Jr .,i. r' �. PRODUCTS• MANUFACTUREIi'AY' APPLICANT Pr`oduct'��dt"J�� 1 ' Ji3e' '-' "' ' Dimensions I ' I ' ": Test '`'' �' " 1f i ''' "11-} -'''Product Iiii riptiiin'i' . F. 1' J .P'. A;t'., >, I::,.a. `t�;t' J. i r..,:, _ t7r.i",i`- 1 -7C .{ i ri ' i tc) .17s t'i 1 LIV ?, P,- 11 1'1 .x,i,..1 .1 ( irr t.'F t+ri ' Secificatioris.a + • r :,1 + 1' , 7t,1 i. •ri J •''i,,I , la:it'' f;i`!t`tAlkI tit t ! ?.Je(.frt;i i y. S„ !` l it :lilr,SLJ. i its ICP1Adhesives .,•o , lr,r I. „ r ,, _I, N/A , i,r, „:�iTAS 101f�,„tt ttTwo ycomponent.polyurethane foam adhesive •:•IQlyset®AH-160, i 1 i :'.•" •1 t,7 t.!^r 3cll it l ;+ r1 t J lit rift t`, 11 i}i itJ ! i. +7ll.:irI Ji:rl')l�t F11,J0 t,) .:. J P,Adhesive3 •Foatp Ef t.4.. I.,'T;i'iN/A) i l;rr d t , 1 t1i r,•'P,. 'i' le.,Dispensing Equipment'g `' I'll .►'r , •t Lg1 ' tn•t' t) • DispenserRTF100Q, • ,$), z,rubti"Pr 1'.4'r 11:' ) • ICP Adieci'%Protfiel . n,. N/A.) .r, ,i4.7t.',,.r" t., 1: i -la' rr,. Dispensing Equipment •n' ,t1 ',ral,tr: t 1! I ) tl al l.t, t ..•'1 ,' t• .:I - A i:1 'Ji.o� ` r_t'tv -.1 ,.2 . `' i / ('a41 i 511 .k11. fi' l'; �4.: •••P '-iii i'1 'arlet a,.i,,,t111). r)1 ;".01(f: i1#').._ • • • •PYtODu ,T MA14UVACTURED BY OTHERS: • •• • ••AllyMiinii;I�p▪ de:CqurtlyProduct:Control Accepted. Roof Assembly having'a'currenf NOAtwhich'list'attachrrient S : resistance tlalues with the use of ICP Adhesives Po1yst® AH-160 roof tile. adhesive. • : x, ' MANUFACT[TRING`LOCATION: rt t •r rift 1t, r;., r 'rsfl.; l:t'i 1•.11i?1t' , *CJ !1 rt, A t , tit '.s. e' i f ,Jim . 1 Ar .. '•t'tr a tf r,, r' t f :Jr 7"* '11 ') ti: Er (s •;,'t Ja11.1': TfAlf ,., :Ili . i, M ,1 1. Tomball, TX. ` _r; :l' ')::rtt ' •t; 1' t • r ..t: , f II 7'1(ir '1 't?,i3 ; . '1.iir,, .I J'si . , ':C..)r. ,, ) P i •f 11't •1(I MTt ,,`i it 1 PHYSICAL PROPERTIES:' o • ;a d` i) i' 11 ., <:, .c 111. -e?.3:E 11 tit 1,1. A . J MA: yl:iitrf: tt r.•,: _i;t'Prouei'ty( ;}t ',;alit, 1 ,,1..t'` ''‘-Test'r""' ' .);."1"1" Ls•i. E.iq''itReiultsrl Density Compressive Strength I 0:1'2 Tensile Strength _, '�' , , ASTM D 1622 1.6 1bsAt:' ! ,ASTM-D,1621 , 18PSIParaTle1.:to rise , ; 4• 't 4, ': t e1 11 ; 1,,1,: r:Ei✓: , li 1 rr_rt tl 112 PSI Perpendicular to nsej• ASTM D 1623 28 PSI Parallel to rise Water Absorption Moisture Vapor Transmission Dimensional Stability ASTM D 2127 ASTM E96 ii ASTM D2126T1' t' 0.08 Lbs./Ft2 r,.13.1 Perm Inc it:t f , •c1�: t ;%'�1�E' );; ',;#,+ +0.07% Volume Change,@ -40 F., 2 weeks • r: 1 '.+6.0%Volume Change @158°F., 100% Humidity, 2 r1 I .fr is .I r S i 43 f;0 1;11 l 74 A EL 1J 1 sweeks, ` i_ ...i' r' , ,� 1 Closed Cell Content ASTM. D-22&56 1-),, OA!,a ' f/`:l•,. r l. ,. ,t7 (,,,,;Li,-,,j, , ,' t, ,j Iv, i:'. _1 (4 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. fi R NOA No.: 322.03 Expiration Date17-0: ,05/10)22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering i 4.F • Miles Laboratories Polymers. Division Ramtech Laboratories, Inc: Southwest Resear-ch.Institpte Trinity Engineering Celot ear Corp,. Testing: Services , Test Identifier 494-060' r" 257818-143A' 25-7438-3 '25-7438-4 25-7438,7• °t 25-7492r NB-589-631.: (il 9637192 '01-6743-011 01-6739-062b[ 1-] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1, ,, 528454-9-1 .528454-10-1 520109-1 520109-2" 520109-3 520109-6 520109-7 520191=1 520109-2-1 Test Name/Report TAS' 101 TAS'101 SSTD 11-93 - SSTD,1:1:-93; SSTD `11=93 • ASTM,D 1623 ASTM E 108 ay. Date 04/08/94, 12/16/96 10/25/95 1; i 11/02/95 12/12/95 ' 02/01/94 '04/30/93?a r ASTM E 108 ' 11/16/94" ASTM E 84 ; `t ' 0.1/16/951 it : ly TAS 114 • + Q3/1196 ASTM D 1623 44/18412 TAS 101 ,, 02/21/12' TAS 123 • . . -TAS:101..', , ; . ;;,..•• I 102Y8;' .,;-: . ...n •• .. .. TAS 101 •, • . • .. • •. • • • • • ••• • • sj 12/28/A8 ... • . . TAS 101 03/02/99 4. • • • LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3 Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI.DADE COUNTY fill APPROVED 4 t. '• NOA No.: 17-0322.03 Expiration Pitt, 05/10/22 Approval Date: 04/27/17 ,. Page 3 of 11 au r a ii'ta.i , ,I .1 ` MI is-4 INSTALLATION: l -.. i, t t-{°'''1 }il__'. lLJ. '' -t,i r S.7T#'1' iIII6.1. `91 '.1,--,: psi*, 1. ICP Adhesives Polyset®-AH-160 may be used with any roof. tile, assembly having a current NOA thatlists �..„ attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. 1CP.Adhesives Polyset® Al-1;60 shall'be.applied in comphance=with.the CorcaponentApplication section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing "Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be'm"stalled in accordance with Roofing'Apphcation', f Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Bookle't:' . ' ' 4. Installation must be by a Factory Trained'Qual-ifie4.Applicatoeappraved• and licensed'by ICP`Adhiesives and -11, Sealants',Inc. ICP Adhesives and SealantsInc. shall supply a list of approved applicators to the authorityhaving jurisdiction. , , , 4. , - r 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of ap y adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.049, tA): 1.11 (B).• .-1? ' 9 1/4" 0 fiPi , • ... '. -t rr t,ji a . • -6. ICp, r .swes•Po11+Set® AH-160 shall be;applied'with ICP Adheswes Foam Dispenser RTF1000rot ICP Adhesives Prordl& 30 & -100 dispensing equipment-brrl`y: `' ' . . . rT 1 e • 1. ICP . Adhesives1.y,s EQet® AH-160 shall not be exposed permanently to sunlight. • • • • • Tiies must be adheHd in freshly applied adhesive. Tile must beset within 1 to 2 minutes after ICP Adhesives •• Polyigt,'•AH-16b:lha:been dispensed. 9 '<'-1 P. A . 9. ICP Adhesiveetlysrt® H A-160zplacement and minimum pattytwerght shall be in accordance with the 'P1ace-4i iit Details' herein. Each generic tile profile requires thetspecific placement noted herein. • . - . • . ..• .. • . . C • .. . _c`{4 ;I( (.ft11" r`Jt 1 ;p/llr, g' I ,t4 f lt>; -4' t •'1 ,;t1 t a . [;i°;J t t tdrx, b! tj ..{{"/,-rf ,1 t. .�. ♦ 1_ . 0 t-91, . jr, 1, id 7� il, 1T)7 !kit 1d, 1 -Iw, LA t' Jf' 11! iL "rt up. —LI 'r,:.tt-UI, 9.'• ', 1:'" �!l:rr.r-,t 9• (11 ti .� 'k.?i17�9C39"l 'c:it.'i't°�1 ✓(�� ilrt"N . siUi)-t);...t 10 11uI1," .i!'!t' , ,if[} t ].t .tti ./ ,11 i.) (I. r 1 i,, MIAMI.DADE COUNTY APPROVED OA No.: 17-0322 03' Expiration Date:`05/10/22 Approval Date: 04/27/17 Page 4 of 11 Jrri Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile •tar , 3-., : Placement Detail Minimum Paddy Contact Area Mininium7Paddy Gram Weight Eave'Course Flat, Low; High ,_ , ' Profiles . t. ' ' All Eave Course ' 17-23 s inches q• 45-65 4 Fl`a,t,•Lowr Higfi Profiles. ' ' —1- 1 17-23 sq_ inches. 45-65 Flat Profile #2 10-12 sq. inches 30 Low:Profile } ' + r' #2 12-14 sq. inches 30 . 11 High Profile 1 IJ •1. ' ,. r ' . #2' 1 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two.Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at overlap •12 grams per paddy Two -Piece Barrel (Cap Tile) a} Two Piece �r ;�+ 2 Beads (L each longitudinal-" edge) 20-25 sq: inches.each P bead .; '"' 17'grams per'bead - -•-•-• . -.. --- .- ; • . , • 1,. • • • - Two Piece Barrel (Pan•Tile) ' , , Two Piece 1 65-70 sq.' inches • ....34 grab's drider pan • • • • LABELING: •••• • • • • • • • •r ••••• ••• •- •••. • All approved products listed herein shall be labeled and shall bear the imprint or identifiable narking of the • •`• manufacturer's name or.logoand following statement: "Miami -Dade County Product Control Appti ved" or the Miami - Dade County Product Control Seal as shown below • • • • , •• • • • • •- • , - BUILDING PERMIT REQUIREMENTS: •• - •.• •; • • •- As required by the Building Official or applicable building code iri order to properly evaluate the installation of this system. , •n •r, • • • • • • • tom' NOA•No: 17-032203 Expiration Datec--05/10/22 Approval Date: 04/27/17 Page 5of11 • • ADHESIVE PLACEMENT DETAIL # 1-, 3i3a" dt ilii 'i { s `Flat/Low Profile Tile . i+ix, t:t ti st t1"# i`1 I lliltt111 ';es' 1. _Starting at the have course, apply a minimum 2' (50.8 mm) x 10" (254 .mm) x 1 i;(25.4 mm)foami s "1I:°paddy onto the' underlayment positioned as shown, " under the strengthening rib closestto the overlock of the the being set. _ ' wady (Q•n•adt Tda) fstiunrfli Rattem optfonai Eaw Goirs* t.t. . .+ ., , • AtI • • • • • • • • Matt throt;h plastk moment • Iwlrn reckldred) • • • •. tti UndAlsynrhte t • • • • . . 2tn..ad •_ Battens optional • • • .. Ga.*teura. • +i, el�^_'-. Paddy 14q+ieath Till Tas ncst,ra, tlLft ,I tit, 1 t, 2. Continue in same manner. Insure approximately. 17 4 (109.7 cm2) — 23 (148:4-cm2) square irich,adhesive contact with the underside of the tile. '' y"r `' =r: i •tci r t. t '..1t11,t 7 7 ,J Medium Profile / Double Pan Tile 1 Starting at the eave course; apply, a minimum 2',,r (50.8 min) x 10" (254 mm) x'1" (25.4 mm)°foam' paddy onto the underlayment positioned as shown pan.thee.l„u overlock of the tile being set. _ + !! I t .1? tin I:'idt .'la°, I._:A).t.I! 1 t. as 2 Continiie'iii same'nianner' Insurerapproximately.1.7' (109:7 ciri2)"i223 (148.4`cm2)'square,inch adhesive( t`5 �"s. , , contact with the underside of the tile. y a 1 i�,3 4I 4. '_1 ) ,f e� fir.%t..r . # rdi l'i I;i .i1ilt�l'.rtll, i. 1f3 ;At" `.Ii qI: '1 ^,i'' iin `4% Nit.(_ 'v4-1 Ve fJ: High Profile / Single Pan Tile `, 01 I. 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto,the shown under the pan.portion'of the tile closest to_the- overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA. Nos.17-0322.03 pir E 'ation'Date: 105/10/22 Approval Date:604/27/17 Page 6of11 • f ADHESIVE PLACEMENT/DETAIL:# 2,:, !Waif through WA Olt sa ment {wtwo required) t►uewtagrnant 74t.v42in; ,.jt BJtt•Af epthrnal Ewe Course love Oesure, Par Ib n•ah Tile) tirItr F,11,43.1 - Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm)' x 1" (25.4 mm) foam.paddy onto the underlayment positioned as: shown under' the strengthening rill' of the tile closest to the overlock of" the tile being set. Insure approximately 17 (109.7cm2) 3 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned:as shown under the strengthening rib closest to the overlock of.tlie tile being set. 3. Continue in same manner. Jnsure apprdtiMdttly 10" (64.5 cm2) - 12 (77.4 cm2)•squtrd inch adhesive contact with the underside•oft4e•tile. • •••• •• Medium Profile / Double Pan TM' • • • • • • • • • • • ••• •• ••. • • • • • •• ..•..••••• • 1. Starting at the eave course,•�lya minimum 2" (50.8 • • mm) x 10" (254 mm) x 1" j25.t1 dim) foam,addy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlttic df the • tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 .cm2) square inch "adhesive contact with the underside of the tile. • 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being,. set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17. 0322.03 Expiration Date: r 05/10/22 Approval •Date: 04/27/17' Page 7 of 11 • ADHESIVE PLACEMENT{DETAIL # 2 (CONTINUED) 11.11ebr i`t. 7 n: ri • • '1 }•t •••� •r;:••_-• !.�: `: ,' ��!'., 1; i ,hi`,11'.`l "l 3.'rl is +.i, l rii ...� . r.0 f• r trs 1 li! t:liari► fllt;i , r t)'. ;.iri.`A lair i r. Ali It, .:;}` (fir• ref-5,Ce ht1;4 !t'"f i i .Gr! r r (1'"t'i `'` i ) 1 +', 1 ;fa, ft l rytt� `.1t1 fit 1i:1'Tr 1. ': i11 "!ri! 1`) 41""t1+3'•1 :i.('tl,s lr1r1i: -,t;4rrlt .ijl n '' l ;=1 `•1It.ttI i 1 1,11 rrt.. ) 1 :r .14 + i .}'tt r!I i'. ' 1)I_,r1! J1lt 2?iV. t'Jii11 r_ ,1.1t,,l ,rt rl,' . s.,`,itS,s , t. i ,1eti t MIAMFDADE COUNTY APPROVED i r i tt r a:10`4 21n. Batton optional 10 Paddy lb•naath Tito) ' t a '1'11`l.: ) •`!11 -yt t, ,lii 9! 1)1 taw dosw, Drip alga '► f '1.,,1.1,1,:.•r i4,1- ;IJ i• 1 1:.111. MSc' ` r ;.i1,11'r1f1 • • • �:'v.l11,alb.. Z'n •. -I • • • • • • • • • •• •• • • • • • •••• • • �'t c Hi'i )Fikilt01.1 111101,-)V • • • • •••• •• •• • • L rs ,.13" a t. •.ri if if' • �'". ''• .CT • I / trig 4-:f)..O! ° tnin Higli Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 ram) x 1" (25.4 rnni)=foain-pad0 onto the:underlaynient positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4'cm2) square inch adhesive contact with4the underside of the tile. 2. At ,the second course, apply a minimum 2" (50.8mm) X 7" .(177.8 -znm) x 1" .(25.4 thrn) foam •paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being' set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. .liltt s',• •,° `•i l•'r e,r• ' r :V 1_f ` )1 a1`+11 SIl !'1110 • • • tt s a , "t NOA No.:.17 0322.03 r1 ,.. r.. " Expiration Date:, 05/10/22 Approval+Date: 04/27/17 Page 8of11 t• , ; ; f l ADHESIVE PLACEMENTDETAIL"#3:' Flat/Low Profile Tile Medium Prof leTlle ,.1 "'On`the nave eourse onl; apply a minimum 2" (50.8 mm) x 10" (254 mm)'x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or. under"the "pan portion of the tile for low or hgh:profile tile closest to the overlock cif the tile being „set. Leaves approximately 4" (101.6 mm) upfrom the ave edge free`of foam to -prevent the expanded adhesive from blocking the -weep holes. ,Insure approximately 17-23 in2 (109'7-148.4 cm2) of adhesive contact with the undersiderof the tile Apply a 4",(101.6mm) x 4" (101.6 mm)`x-1" (25.4 mm) foam paddy onto, the underlayment just below the `second,course line positioned fatal paddy under the strengthening;ribtor flat tile, or under the • • pan portion of the tile, closest to theiantiertock fqr, • .:. the second course tile tq Insure approximately 8-9 in2 (51 ir58:.1 cm2) ofadhesia+e f. contact with the underside•othe tile. • • • • (Instructions continued on rte17 jn'a e) ..•. • • • • •• • •. • • • • • • ••• . • • •NOA"No.: 17-0322:03 Expiration•Date.05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT'.DETAI1:##13•(CONTINUED) 1WSinglepaddy undertile ',u ., fill:: r /tits• ddiridndertile) ••-)'1' {.'• 7.1-jr %. H1 iiProflJ Tflef' .Hdi 1,1,1u • . r ••!.•• {S. ,•. 1. • ?r,'rl i->.• rr1J �lr I .Pc, 7':I.i Tf .(; 17l:L1 • • J i{-li i,;i,, Jj;-tt•'r! :,1 ,'Si' s, 1,•1� t,ti��'`� "3617 • .•''t t• r•' r. t'•i••" ' • • • •. • •• •• 1.Jn.••.• ';"1-11!'JG.4r(19 •••• .• . • • • • • • • •• • • • • •••• •• •• • �'.•:,i• ' • 1%k) it'.q' 3t,:t t%,1 • • • • • • ••• • • •• • • • • • • •• 1 3. Also apply a 2" (50.8 mm) x 4' (101.6 3/4" ,: .. +.(19 mnt)padrd on to "of the eave cou se-til1 surface as shown,-on,top of the' strengtheningrib for flat tile or on top of the pan portiori`of the tile, closest to the underlock of the first course.of tile. r >• � . Install second course of tile.. Insure1r approximately } 9 (58.1 cmZ) - 11 (71cm2) square inch adhesive }; : ;contact with the underside 'of the the at'the overlap € - and 7(45.2 cm2) - 9 (58.1 cm2) square inch adhesive=contact With the 'undei-side of the tile at >:l:.w the head of the tilerContinuein samenianner 4r ::1;• .r h' I- i A. T'i lP? .wc; + .tel . , a -A y A iZ}w fl .. v • • a„• w ,. 41t �4{e!Il�wifR�'<:.aiNelt,+OgwAi.4a'.H.�'�nt.shR'�a �'bc'r.'.�APtllI4'�'aM . T -.- NOA No.: 17-0322.03 Expirariot.Da`te,0/10/22 Approval'b brae: 04/27/17 Page 10 of 11 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumter•ville;FL33585 p' t° �,a, ,� + • : r ..1. i, i A . MIAMI-DADS GOUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 •' ' Miami, Florida 331;75-2474 T (786) 315-2590 F. (786)_315-2599 a: 7www.miamidade.aov/economv SCOPE:'P'''' • ., — , .!,. }. r,., .'• i• . This NOA is being issued under the`applicable rules•and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade Coiinty''RER'-Product Control Section to be used in Miami -Dade Countyand other. areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade Colinty)"arid/or the AHJ (in areas other than Miami -Dade County) reserve the rightto have this'.' product or materiaLtested for.quality assurance purposes.'If thiaproductor.material fails to• perform in tare•a mpted manner,•the manufacturer.will incur, the expense of such testing and the AHJ may immediateJyretoke,;lxiodi fy, or .1 . • suspend the use of such product: or,material;within their jurisdiction. RER•reserves the right.tp.reyoke dit?acceptanea; .:• if it is determined by Miami -Dade County Product Control Section that this product or matoiaat fails to meet the • requirements of the applicable building code. • • • • • r. +-^c. YI 7`�.r �,. .< Ti.2., p_i;< I j e`e a .l ;i •� e y; •• • •. F �'T lie_ " This product is approved as described herein; and has been designed to"comply'withythe. FlortdR Building Co8e • including the High Velocity Hurricane'Zoiie of the Florida Building Code.: • I il'' , _,. ." 1{,i r:', i' s , , •• •• •••• DESCRIPTION:(High`Profile-Concrete Tile • • •• • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,•ci4, state aigd.following• statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • • RENEWAL of this NOA shall be considered after a renewal application has been'filed'and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOArevises NOA No.1.6-0314 08 rigid'consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino • NOA No.-17-0822.15• Expiration Date:,10/05/21� . Approval Date:' 10/26/17 - Page 1 att'I ROOFING'ASSEMBLY APPROVAL t+r,1L1 #, :Pr ''t7J.1 ,CategOrv: ,: •., rrr Roofing u.1 r3 15('.1tr%.i 1 .IF,,{tAft .: fie* r3{t5`V.H,1 J0 15111) :,-r%i'i;ti a1'{^{ 'Sub.Categorv:-?; } z (vRoofing Tiles 401,11111 , )11 t q`r .1w,14141A uh ° } zt'i flu +s', Material: ;Fr.,.l. t Concrete 0i4 rl1.4 :.1'' :3 M`''( V" 1. SCOPE:�'� This approves a new roofing system using High' Profile Concrete Tile as manufactured' byEagle -Roofing -Products ,LLC=m Stinterville, FL ond detctibedin Section 2 ofthis Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure •values obtainedby calculations in compliance with,RAS11271using the -values listed in section 4 herein..The 3h e,Jattachment,calculations-shall berdone as a moment based system. f,;i,„ 4 r . ;# , ,`1; r .3,s i,c`,,„ inl,h}c E.4 .11 _ — .,, i " 't ..' .. 1 :1 f L. .M '•t t r !- 2. PRODUCT DESCRIPTION: C •111C t} ' ' 'C1it+�lt ', 1riull J art ;^+fftr i }v. r f it 11.1' .+lu:l it")1'°i 1y`r .F' t a 111 !,r':' t1 ir,{ fir •rM t 'p {EiT Manufactured by - J, f'1{=TSIft` rt �'^:t:t+> ' Test, t•d itc, ' . L1 .'1 l.r' t 11 (-fr, Product ...,;. - l l2 rci !., '+, 1,-0.1-,Atninitcant t,i ( .;'D1i11.ensiOt15:'! .mot' SpecifIeations 1 i� �c#'�r5 ti#i, '.'Dfs' eflDt1011°i` t '"'t , I i'i(+ F? • • '• • • High Prfle Goncrite'Tilt 11 "Lenght , I7":.'dt t'fZrTAS 112 {4'' "High profile concrete roof the ,,F6rrdirfect deck of • • • •D{,` • ,. E„'g••, 'l •. ;1'1 .Width,-12''/a"`1 •r'r'11Type la a°, liattened'iiail=on'applications. r, • . r ;t'7L;: �1• t-li •...r it r' aurt, Thickness='/2"r,rl: DoiClass'Illf") ) t...`,01(1 root } 1. "'CI itrrl t- vr1 ` -r `1.1... �, ; j }:°+i • • • •.... '.1 EJr - �- ,+ . • •Trim Pi�chsa • • ' • •.. • Lenght = varies TAS 112 Accessory, trim, concrete roof pieces for.use at • • uit :t41`€rliri • • • • 'Width = varies , 1. , f flips, rakes, ridges and valley terniinationS • • • • i+• ' %ttfr.',}t tL! ./_• �Yi,1 t + It It. J '' • t.1 1 ix.. 1.. ;( •1 i I.. S# {}:.�rfii1 • • • • • • • • • varying thickness ' Manufactured for each tile profile. •• ' • • • fir'€`' `1.a;)`6date)Aito19 alpi- ; A# tellq"-t 0 • • • ` : ••i'r}'_!r1 ter Jrrtt. 1 'S>>r,i t L lit. t Al .11. " )1} :' r ,,rte : r(, + 1 , '' 1'r i;,r, l'')t +n y?i"rt`;f1 , -', =r 1r . r • • •• riff i.r ,,, J i .v .. ,.1. .,., r , / `'I tid,', it; 6i �:, r.1 .t...Jt j..L?I t.£ tJ' ittr,11 , ;t ri `"f.' rt .r' �+ 7r. `"f:Slilt' fl° f{ ri }Jr° J ! )- .. lilt': srrai, )I rri. 'tr ?•.• 11, n,.i�", 0,i ,. 'i 1 `� L0' .; It 10;,•tr:rj nl.rt..'t'{1'f,� .. fiF'1' ,. `? In �1r:1 �;1 J/- i:lt , , ,'1L)1 r.t, xr .i'.dtY ��rr }1 (iv it, rrr,rrl, .r+t}1'.f rt. ✓[. '°„ii`i 1.1 r 97Cs?,1 1 .,r{iEi J4: b. `1 t-.;r .nt3r' 1Pti• 111, t.� �'- rr e E•0 ri II1'; fain('#)+)1 :, . r' (,,` i1jj j'!r;l' .1 7 t i�. rlv.+ l r' a. f, .1 -1.< •'} ,$ ft )r 11T1a' :ii! ;1 .l 1r} .1� f.alill r 'ltli 10 t l �`"r'ft11:', 11.i fli:ri l "1 _V .11.1s'r i ... efl ICrit r!'.' %i+,rl>' 9i•r `i)1 ' ,f1 J "rl►t'T '.()' '11 1 +.,1 r r .�`t � iire "t1 r9.'. 1 ', Jd .' tt l.i tl 1. 'v: yfii 1,t r'r!t1' E' r(•'�. IIli. , ' I)' 4rrtt {1,,."+ is :!il ,oar}` I til; I ;'J ,t ,t1.) tr. 14_641'.1#' .}+ Ji t:� f.i1 rrirl.� ::111n {`fGD ' t '14?8 • 100 1''lttp . I lil> '0 ;,`rJ rt ,'4 5,11 'r; r+ it' i r+}drrt "f+}i �'i ' 1'1. 'i, se 1 .1tt1, r• ? 5S: i3ttiA, #3};► t :,'1 } 1.+'} rr` ? ✓ a i '.L 7 1t9 i,1 „}, ,; 3t�1s *.�ijtr. IJr 11 NOA. No..17-0822.15 Expiration Date:'10/05/21 Appiova1�I)ate: i=10/26/17 Page 2 of 7 2.1 EVIDENCE SUBMITTED: Test A2encv PRI -AsphaltT'ethnOlri!gies' Redland ,Technologies Redland Technologies. Redland Technologies I Redland Technologies, The Center fcifApplied Engineering, Inc. The Center for Applied Engineering, Inc. The4, ,t • t14/ Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc The Center for Applied Engineering, Inc. _ 1 The Center for Applied Engineering, Inc. .•4.i. 1•:.0 telotex Coipciration, — 520111-3 Testing Services 57799443,. 1)f-&,9)„ 25-712041.&.2). 25-7183-(3 & 4) 25-7214-(3, 4, &7) 25-7864-4 Celotex.Corporation_ .(.,1:11520101-2-1 .___ ... Testing SerVices 'SY. i .-.7.' Test Identifier LERPF401-021-03 r'j h4 - 7161-03 . Appendix IIF Letter Dated Aug 1, 1994 P09647-01„ t.' 1.#•.„rt, ...„„:P0402 t ,Test Name/Report • ).;,;J TASL112 Static Uplift Testing 1.1 TAS 102 & 102(k) (s Wind Tunnel Testing TASr108 (Nail -On) With ,0 Wind Tunnel Testing TAS 108(Mortar Set)1 , •,. ;# clrawa.1 Resistance Testing of screw vs. smooth'shank nails 3. 94-083 Static Uplift Testing TAS'101g(AdheSive Set) ' r 94-084 Static Uplift Testing ) TAS 101 (Mortar Set) • ,t .0 4 .• .• Static UpliftTesting &I. • • • TAS 102 • Static, Uplift Testing 41 , 9TASi02- Static Uplift.Testing TAS 102 Static UpliftTesting TAS 102 TAS 1-02 - Static Uplift Testing TAS 101 TASTOl Walker Engineering; hicT :CalCUlations," • • Aerodynamie-Multiplier • . Att1,81SOUtRT12i1.2iL_ - - • ; • :.t- `r.1 (-t ATL of South Florida RT0706.03.17 TAS-112 Date ‘urAtig.'2006 .Dec.01991 YJAug1.11994 Aug. 1994 ,Sept. '1993 • 1994 Mv.y 19.94 d • 41, • • • • ' f • • •• • • • • No,e. • _ 1.99;1 _ • • • • • • • • • • • • • 9. FebillinS • 9 • • • • • . •iMallir 1995: t • • • • • • • • • • • • Sep. 1996 • Diec. 1998 • • • • • —March .1999 r Sep. 2006 f2/17/1.5' 09/25/17 NOA No. 17-0822.15 Expiration Date:40705/21 . „ „ Approval Date Page 3- of 7 • • •' 3. LIMITATIONS: :tl:l7 Pit'pt.,1? _ :Y+' `' t r 3.1 jFite classification is not part'of this acceptance. ?71n:,tt;_tz I 3.2, tFor,mortar or adhesive set tile applications, a static field uplift,test in accordance with TAS 106shall .be�,q required, refer to applicable Building Code. 3.3 'Applicant shall retain the seivices olalMiami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 1121appendix `A'.1Such testing shallybe suliinitted to the Miami -Dade County • Product Control Section for,review. 3.4-Nankai. underlayrnaent shall, be,inccompliance with the aPiklicabliRoofing Applications Standards listed section 4.1 herein, trtt �`it .f t '�r i .i ICJl0_'j t rl `:1' l'.iSt; 31 l 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6.:1Thi`s acceptance is -for wood, deck applications`: ' -Minimum deck requirements shall be`in:cornpliance with applicable Building Code'. m +ir /. ;01.suri.c "' ' 3.7, TAIL products listed herin shall have aquality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the,Florida, Administrative Code. t „i.f _ rtf, ; - it ffll r.i1z F;', ' �. h.,flri if lot 7 '• t.l� 0 �. 4. IIVSTi1i.LATION 1f tf 1 �nf '°t:it 4.1. Eagle Roofing Products LLC, High; Profile Concrete Tile and its components shall be installed in strict i"•'Compli ���ith Roofing'Appiication Standard RAS 1181, RAS'119"and RAS 120.E ''' 1` 't i .•rr_ al�.a 4.2 • Data Fordttachment Calculations, i ` fs; say • ••• •• • • • • •' • • • • `•'sr •r'4 •••• r t,t,-7n., .1941 l • r I. • • • • • Table 1: Average Weight (W) and Dimensions (I x w ) ••• •••• •.. ' 1" a Rrol re' • • • WeI ht4111` (Ibf) Length-6 (ft) Width-w (ft)• I: !i 1 High PrOflie Ogncrete Tile - 0i,, . i i11101. ''._ ,•, t' '1 ;1.417 i'..-' -e'.:. 1. ;rrT,ni{ .1:041f i 4: i • • • • • • • • • ' • •,.. .Table•2: Aerodynamic Multipliers -A (ft3)_;., . r-:..•: rt!. .," ,. {.. ; r-r Tile Profile . A (ft3) • Batten Application ( A (ft3). g t Direct Deck Application .{' High ProfileConcrete Tile t:: s r 0 St,'l f .P , '=0.300 t ` _ :.'_,r 0.277 f '. -T -,'. '. d it t.,' t,! r ,I.,.,, A _-- — Table 3:.,Restoring'Moments due to Gravity - Mg (ft-lbf) T= ,-,,:,:,0-.,, r 1 ;tr , Tile Profile . 11-3":12"- ' _ 41:12"- 5":12" 6":12" Greater than , r 7":12" High Profile .',. ' Concrete Tile ' Battens ,Direct - Deck 1 ''Battens'' .. , Direct' , Deck : Battens Direct'! Deck - `' Battens ' -. ; t Direct' . Deck , ' Battens''' , - ; Direct' Deck, 6.68 6.99 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38 -NOA No.-17-0822.15 Expiration Date: 10/05/21 Approval -Date 10%26/17 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) , t for Nail -On Systems Tile, Profile , . Fastener Type - „ . Direct Deck., , r (min,15/32,',plywood) , Direct Deck - (min:,19/32" plywood)1,1 Battens ,e' High Profile Concrete Tile 2-10d Ring Shank Nails ....,: ,,- 28.6 , 41.2 19.4 1-10d Smooth or Screw Shank Nail ` _ , ,-,5_ 1- - k �.P r .. . -ram 6.8 2.8 2-10d Smooth or Screw,, ... Shank Nails .. s °Y. ., .6:9_.-..Y; , . _ i-t '.: , ; i_ .. 9.2 L.. _ 7.3 1 #8 Screw 20.7, , 20.7 18.1 2 #8 Screw .,-43.2 a t,., . ,1 0 .. ' 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field Clip) "'23.1 ' ,.."""- - .. 23.1 19.0 1-10d Smooth or Screw Shank Nail (Eave'Clip) A °; 29 33 ., , a_ . 1 # '' 1. 29.3 24.0 2-1 Od Smooth or Screw Shank Nails (Field Clip) 27.6 " _._. . _ . 27.6 38.6 2-10d Smooth or Screw Shank Nails (Eave Clip) ' '38.1 38.1 41.8 4, . ..•.-- . . •••• 2-10d Ring Shank Nails' 33.1 48.1 •••� • :.-•:45.2 • 1. Installation with a 4" tile headlap and fasteners are Ideated a min. of 2'/2" from head o1•tflta: • • • • • • - • Table 5: Attachment Resistance Expressed as a Moment IVit,( Jbf) •, • •.: ,. . for;TwooPatty Adhesive-Set"Systems--1 .... ..:. Tile Profile - F `�' 'Tile Applications -- ..Rliinrmum'AttasRiment.••• Resistance • High Profile Concrete Tile Adhesive il7 ? !a''• . re_,I i ",c, i r 9f)..r. • ,,* ‘2,X .; . • • • • • •• • • • •• •••• 1 See manufactures component approval for installation requirements. • • • •' • . •• ' 2 The,Dow.Chemical Company TileBond Average -weight per patty 10.7 grams. • • PCP Adhesives Polyset® AH-160. Average weight per patty 8 grams. Table 6: -Attachment.Resistance Expressed-as°a-Moment;- Mt (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance High Profile Concrete Tire ICP Adhesives. Polyset® AH-160 66:5 ICP Adhesives Polyset® AH-160 38.74 3 Large paddy placement of 63grams of Polyset® AH-160. ; ' .r r' i o a a,.} 4 ' r i" r ° r w : r ' ,., 4 Medium paddy placement of.24grams of Polyset®AH-160.,.,, zr.11.,, ; ,: r' .r r, , ,,. ,1 ,r. , r ., „l Tablel7: Attachment, Resistance.Expressed as.a Moment- Mr(ft-lb'f) . for Mortar Set Systems i Ji,t .,l,;'i. , . 1,•11' Tile Profile Tile Application Attachment Resistance High Profile Concrete Tile Mortar Set5 24.5 5 Tile -rite Roof Tile Mortar. NOA No. 17-0822.15 ExpirationTDate: 10/05%21 Approval Date .1.0/26/17 Page 5 of 7 • • • • • • • 3... :..- ( aL rX ft s r� Ro •Rf Y T i 5. LABELING . €' c3 g31,1 r3 ^ p-ti ,-) ri ' is b...,---N s>.4. 3 tafala. ;� 'n tr3rt,)n i� alp as#:.'t R All -tiles shall t'� lieu the imp'ii or identifiable. eking.= f the anufa rer's'- ►e or logo -(Sees • Detail Below); or;following statement:'"Miami=Dade County Product Control Approved". +311''(134 ' ►`_ ( 1 .. r r 'i ,. , :JI_;2 'fl tint`)) . Mt ' co, 1 ,f- a erl.r.)r1 . +RC- _ 1% �► V a.'"?, '1O 4 o Jrt7? h t l i .'' •• a 3c i • :t2 3.- 1 17:LORIDA L. i .. i')10v 3j ,iji..lr.-, )lre a1'''r- (LOCATED ON UNDERSIDE OF TILE) - ; : - ` -• - • • icc) vc 11 &3 , 'eft ,ilr • • • 1 • • • .D t'r• rti muss a T.e 1� OR, =I.4.- �, , t.. C1.1. et ?r1 - — • • • • -•_ • • • • • • • •• •� - • • • !eR •-� �lr il44.i1.4 a +?' r.t3 e'etgx-73` It rr111 JM to rs r a, 1. n ;•,1st!_ 14�tI3 • l _ 1.. ;lri,9 • • 7 e • %F. • • • 1 _. .. _ . • (LOCATED ON FRONTSIDE OF TILE) •• • • • w. • • - t'�n i'6;3 hrk 1t31.lt'41 ii1`» i .:1AaiJCit �`tf"f • rt: •. �`t+� f (X11ilt, :.t" F' iat 1(iE it tt. 3 1r' - "j"" eTt.t. 9r. 'ti! s.Y3 ' t.C? .• j .M.r k..t i f t- a -.- t -Tit r.1.(i. jl•f3{t It .1 Oil'°r iterr-rA t:.rortif`Sri i.' ',�4,,.r1<ri^. (.':)1 1a�t-ltt1 'High Profile. COnCrete)Tile:LABEL;:SUMTERVII:LE'�PL'ANT:1 144 thT .3 n tc? y` i 3% ''v1:•'q11:;e>•! '!isti 301/B T t -) n _' - s` , `.4 J 3 0A q31 el 6. BUILDING PERMIT REQUIREMENTS: _ •1 , t:Nto 1 :�,rs.,E • t:..r vi,.).,1yr✓.- t, C i it , 9 .3{t t _,Y,e n _ 6.1 Application for building permit shall be accompanied -by copies of the, following:, w - ,! • _ 6.1.1 This Notice of Acceptance. _ _ _ 6.1.2 Any otherdocuments required by'AHJ, or applicable Building. Code in order -to properly evaluate the 1 ^ — installation of this system. i114:‘s `tr8 4 C '?. ri_l .. _ _ _ _ i' 1tS. MIAMI.DADE COUNTY APPROVED Dui „Pit ti(1,13 r,zt, tr,'i i a -NOA.No. 17-0822.15 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 6 of 7 f4, 17 PROFILE DRAWING High Profile Concrete Tile END OF THIS. ACCEPTANCE •• • •• • • • • ....•• .... .. • • • • •• •• • • • • • sit► •••w•• • *ID 00 • • • • • • • • • • • • • • • • .• • ••• • • • NOA No. 17-0822.15 Expiration Date: 10/05/21 Approval Date: 10/26/17 Page 7of7 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the,agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. )Venailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). • • • •• • • • 4. posed Ceiling: Exposed, open beam ceilings are where theiuxitWde of the rpof decking • can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, •• • roofing nail penetration of the underside of the decking may not be acceptable •This providee•tte optiongai: • • • maintaining the appearance. •••• • • • ••• •• •••• • �j • • • •• 6. Overflow scuppers (wall outlets): It is required that rainwater ows Q f'so thif t# i of is • • not overloaded from a buildup of water. Perimeter/edge wall or other roof exteiisfbn:nay !Ana this • discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install oviiow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7 Owner/Agents Signat Date Co ractor Signa Date Ne ) 0 8'4 L.51- Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number