Loading...
REV-17-2296Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 'Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2O BUILDING Master Permit No. 5 I - I ISMS PERMIT APPLICATION Sub Permit No. 2N 1=1-222c7t ❑BUILDING ❑ ELECTRIC ❑ ROOFING REVISION ❑ EXTENSION El RENEWAL RECEIVED EP 2 6 2017 ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: l �2 IJL) I I O �F City: Miami Shores County: Miami Dade Zip: '33i G e Folio/Parcel#:1 I- It 3 G ` 0 03 - 01 00 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): c-SeAt 8tx, Phone#: Address: 17-I. jto Sf City: MIA/vv., 51iGvz.5 State: Zip: 331 G dp Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Re ext C). 5-1-0YN Pro j c4) Phone#: Address: t 0 801 ►.l c,J LU• 54 City: MiiNc, State: -EL- Zip: 33172_ Qualifier Name: joY\ A--110.0t�v-) c,j),(19U€,L Phone#:.3a5-5'3' 5' 4. State Certification or Registration #: _ C CMG: 1513 <-'1 4. Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: - State: Zip: Value of Work for this Permit: $ 0 Square/Linear Footage of Work: C. Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: d'W t5i 61'3 1"6 C,c -re PM 1,-WMe) ev oh Doug/ SPY ir`S?e c`�or Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ o Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a einspection fee will be charged. Signature WNER or AGENT The foregoing instrument was acknowledged before me this 6,1Of4 day of ...6Q p , 20 / '7 , by SSA /0 A ld EE - , who is personally known to Ft . »_ Li «,osc me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: as r-J 12 b.r 419Ri--e-.) MICHAEL MARRERO 3.111k s Commission # GG 58774 AIii:C,P$ f My Commission Expires %,,,7,1, ,o December 28, 2/020 ,ysf4 Signature CONTRACTOR The foregoing instrument was acknowledged before me this -ru day of , 20 / 7 , by R del toi ho is personally known, to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: /`7r a e L Seal: MICHAEL MARRERO r `) r -Coma-mission * nr; 58774 s+,1O i rr.s My Commission Expires of f��P ,,,,,,,,,�,�. December 28, 2020 ********************************yh'** ********************************************************************* 62 APPROVED BY Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Sean Albee 122 NW 110 Street Miami Shores, FI 33168 RECEIVED SEP 2 6 1017 ("A 41 Revising correct product approval for door. Garage N/A Garage (separate from house) ..... . . . .. .. •• •. • . • • ••• ••. •• . .• • •• Fiberglass-HR • ... ... FL4V,34.) • • . . . • . • • • 8 . _ • .• •• • • • •.• • •• • •••• •••.•• • • •• • • • • •• • • • • • •• • • ••••• • • •••• • • • • • • ••• •• • WIND LOAD TABLE FOR COMPONENTS AND CLADDING CLIENT: AHe is StoY,Nt Vra"-ec io0 PROJECT: Se) t;c EXPOSURE "C ADDRESS: 2.L t(Pc✓ I (SH-tWve City NW ILO WIND VELOCITY = 175 MPH State 33)6e ZIP ROOF SLOPE > 10 0 Roof Ele (ft) 15 17 20 22 25 28 30 35 40 45 50 60 v. Tributary Area (Sq. Ft) 10 40.1 43,5 410 44.5 42.5 46.1 43.4 47.1 44.8 -39 42.4'. 43,4 413 44.9° 42,3, 45..9 43.6 zo 38.3 417 39.2 42.7 40.6 44.2 415 45.1 42.8 37.7 411.' 38.6 42.1:_ '399 435,; 40.8' 44.5 42.2. 30 37.2 40.6 38,1 41.6 39.4 43.0 40.3 44,0 41.6 35` 36.8 40.2 37 7'' 412 39.0 42:6 39.9' 43.6 41.2 40 36.5 39.9 37.4 40.8 38.6 42.2 39.5 43.2 40.8 45 39.6 37.0:. '40,5' 38.3 41.9 39.2 °42.8 40.4 50 35.9 39.3 36.8 40.2 38.0 41.6 38.9 42.5 40.1 48.6 45.8 47.4 44.6 46.6 43.7 46.0' '43.0- 45.4 42.5 45.0 42,0'i 44.6 41.6 44.2 41.3 43.9 410 49.6 46.2 48.4 45.0 47.6 44.2 46.9 43.5 46.4 42.9 45.9 42.5 45.5 42.1 45.2 41.7 44.9 414 50.2 47.7 517 49.1 53.2 50.5 54.8 514 55,8 52.8 48.9 46.4 50.4 47.8 51.9, 49.2 53.4' 50.1- ,54.4 51.5 48.1 45.5 49.5 46.9 51.0 48.2 52.5 49.1 53.5 50.5 47.4 44:8 48.9 :50.3 47.5 51.8 $48.4 497., 46.9 44.3 48.3 45.6 49.7 46.9 46.4 43.8 47.8 45.1 49:2. 46.4 46.0 43.4 47.4 44,7 48.8 45.9 51.2 47.8 52.1 49.1 50.6 47.2 48.5 50.2 46.8 512 48.1 45.6 43.0. 47.0 '44.3 48.4. 45.5 ,508 47.7 45.3 42.7 46.7 43.9 48.1 45.2 49.5 46.0 50.4 47.3 57.3 53,8 58.3 55.9 2.4 56.9 54,9 51.4 55.9 54.2 50.6 55.1 53.6 49,9 54.5 53.0 49.4 54,0 52.6 48.9 53,5 52.2 485 53.1 518 48.2 52.7 C a. ate Roof Elev. (ft) Tributary Area (Sq. Ft) 10 15 2D ,25 30 40 50 40.1 53.7 39 51.6 38.3 50.1 37.7, 37.2 48.9. 48.0 8 36.5 46.5 45.9 35.9 45.3 17 41.0 55.0 40.0. 52.8 39.2 513 6 38,1 50.1 49.1 7 48,3 37.4 47.6 37.0 46.9 36.8 46.4 20 42.5 '41.3 40.6 '39.9 39,4 39.0 38.6 38.0 56.9 54.6. 53.0 1.8 50.8 499 49.2 48.0 22 + 43,4 58.1 42.3 415 54.2 40 8 40.3 53.0 519 39.9" 511 39.5 50.3 39.2 49.6 38.9 49.0 25 44.8 43.6 42.8 42.2 41.6 41.2 40.8 40.4 40.1 60.0 57.7 56.0 54.7 53.6 52.7 51.9 51,3 50.6 28 45.8 44.6 43.7 43.0 42.5 42.0 41.6 41.3 410 61.3 57.2 54.7 53.8 43.0 52.3 51.7 30 46.2 44,2 43.5. 42.9 42.5 42.1 41.7 414 61.9 59.5 57.7 56.4 55.3 54.4 43,6 52.9 52.2 35 47.7 46.4 45.5 44.8 44.3 43.8 43.4 43.0 42.7 63.8 61.3 59,5 5&1, 57.0 55.2 54.5 53.8 40 49,1 47.8 46.9 46.1. 45.6 45.1 44.7 44:3 43.9 65.7 63.1 51.3 '59.9 58.7 57.7 56.9 '56.1,. 55.4 45 50.5 67.6 49.2'` 64.9 48.2 63.0 47.5 46.9 616 60.4 46.4 59 4 45.9 4 45.5 57,7 45.2 47.0 50 55 60 51.4 50.1 49.1 484r37.8 47.2 46.4 46:kf 68.9 -52.8 70.8 53.8 2 51.5 68.0 52.4 72.0 69.2 50.5 66.0 51.4 67.2 6f5 1 p Vi S4,S'63,2 5d8•II1,9 61$ ' 64.3 48,5 63.3 6 51:2 62.3 58.8 4 .5_ 61.5 58.1 47'3' $J- 48,2 1. 2. 3. 4. 5. 6. 7. 8. GENERAL NOTES TABLES VALID ONLY FOR BUILDINGS OF MEAN ROOF HEIGHT 60 FT. OR LESS. ROOF ELEVATION "H", IS DETERMINED BY USING FIGURE 1 AS REFERENCE. IDENTIFY ZONE OF COMPONENT PER FIGURE 1. POSITIVE AND NEGATIVE LOADS ARE TAKEN AT MEAN ROOF HEAIGHT AND APPLY TO ALL FLOORS. TABLE ABOVE SHOWS MAXIMUM DESIGN LOAD FOR SHOWN BUILDING HEIGHT IN END ZONE. se FIGUR .Z,.• D=10% OF LEAST HORIZONTAL 1:IrIEV18N • ELEVATION "H" FOR SLOPED ROOFS IS THE MEAN ROOF HEIGHT. • •' • •• • r IH 1 D u D • • • • • • • •• • • • • • •• • • • • • • • • • • ZONE 4C=Jl LQ�E 5 ✓✓�z • THIS DOCUMENT IS NOT VALID WITHOUT THE EMBOSSED SEAL OF AN ENGINEER EMPLOYED BY AL-FAROOQ CORPORATION. NO PORTION OF THIS DOCUMENT MAY BE USED OR REPRODUCED IN ANY MANNER, EXCEPT FOR THE PORTION OF ASCE 7-10 SET FORTH HEREIN. ALL LOADS ARE CALCULATED AS PER ASCE 7-10 AND LATEST FBC 2014 STANDARDS SEAL JUN 1 '6 2017 dat•:10-02-13 drown by: M.F. REVISIONS: no. date by description chocked by: H,M. DWG NO. 1 SHEET 1 OF 1 AL-FAROOQ CORPORATION ENGINEERS & PRODUCT DEVELOPMENT 9360 Sunset Dr. Suite TEL. (305) 264-8100 220 Miami, FL 33173 FAX. (305) 262-6978 JAVAD AHMAD FIA P.E. f 70592: EB C.A.N. 3538 • • • • i• :• •. • • •� •• • • •• •. • 8/10/2015 Florida Building Code Online Florida Departmentd Busines Professi Regulation License efficiently. Regulate fairly. BCIS Home Log In I User Registration 1 Hot Topics I Submit Surcharge I Stats & Facts Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email ... . . • https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgttSMGy .. ... . . Publications 1 FBC Staff 1 BCIS Site Map *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Masonite International 1955 Powis Road West Chicago, IL 60185 (615) 441-4258 sschreiber@masonite.com . . . .Steve Schreiber . • . • . • . .. ... .. • • • .. • ... . ... • .• .• . • • . • • . . . • ... . . .. • • . . . .. • .. . . • . • sschreiber@masonite.com • . • . . . • . • • . . ... . . • • • • • • • ••• • • • • • • • • • • • • •• • • • •• •• gTun PuaF1 w HGK%2fQyxxFHIC78%2fE%o3d 1/6 8/10/2015 Florida Building Code Online Category Exterior Doors Subcategory Swinging Exterior Door Assemblies https://www.floridabuilding.org/p Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute, Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Product Approval Method Method 1 Option A Date Submitted Date Validated Date Pending FBC Approval .. ... . . . • . .. • Date Approved •• •• • 06/06/2015 Summary of Products 06/01/2015 06/03/2015 .. ... .. • • • .. •• • • FL # F?od01, tluttiipeor fl f•Orrie; ; Description 4334.1 '4Pberglass Side -hinged boor Units - Imps l atea 6'-8" Opaque I/S and O/S Single Door ... . . . . ... . . Limits of Use • ••• ••• •••• •• •• •Approved for use in HVH: Yl°s••::: : :.'.: Certification Agency Certificate FL4334 R9 C CAC NI005930.01.PDF 8/10/2015 Florida Building Code Online Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70.0/-70.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system is NOT 'required. See anchor detail DWG-MA-FLO120-05 for additional information. Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FLO120.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 504B.pdf Created by Independent Third Party: Yes 4334.2 Fiberglass Side -hinged Door Units - Impact Rated 8'-0" Opaque I/S and O/S Single Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70.0/-70.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See anchor detail DWG-MA-FLO121-05 for additional information. Certification Agency Certificate FL4334 R9 C CAC NI005930.02.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FLO121.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 503B.pdf Created by Independent Third Party: Yes 4334.3 Fiberglass Side -hinged Door Units - Impact Rated 8'-0" Opaque O/S Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code including the.1-ligh•04Icici$,r NurriIate•nne, and where pressure requirements as datermined:by.4SCE 7, Minimum Design Loads for gal dials alai Othel:S:rwetures, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT • required. See anchor detail:Dfo -MA:rief/I-05r additional information.• • • •• • • • • • • • • • • • • • • • • Certification Agency Certificate FL4334 R9 C CAC NI005930.02.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FLO121.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 501B.pdf Created by Independent Third Party: Yes i•• • •• • • • 4334.4 Fiberglass Side -hinged Door Units - Impact Raged • ••• • • • • • • ., • • • 8'-0" Opaque I/S Door w/ or w/o Sidelites • •, • ••• • • • Limits of Use • • • • • • • • • • Certification Agency Certificate https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgttSlly GyvgTunt'uaFTwHM2ftyxxF lIC78%2fE%3d 3/6 8/10/2015 Florida Building Code Online Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.5/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See anchor detail DWG-MA-FLO121-05 for additional information. FL4334 R9 C CAC NI005930.02.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FLO121. pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 501B.pdf Created by Independent Third Party: Yes 4334.5 Fiberglass Side -hinged Door Units - Impact Rated 6'78" Opaque O/S Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See anchor detail DWG-MA-FLO120-05 for additional information. Certification Agency Certificate FL4334 R9 C CAC NI005930.01.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FLO120.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 502B.pdf Created by Independent Third Party: Yes 4334.6 Fiberglass Side -hinged Door Units - Impact Rated 6'-8" Opaque I/S Door w/ or w/o Sidelites Limits of Use - Certification Agency Certificate Approved for use in HVHZ: Yes FL4334 R9 C CAC NI005930.01.PDF Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: Yes ." "' ' ' .. 02/28/2021 Design Pressure: +50.5/=50.5.' ' • • Installation Instructions Other: Evaluated for use ial.l3catibnAJdlialln§ tit) theFlorida FL4334 R9 II FLO120.pdf Building Code including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements as determined'by ASCE 7, Created by Independent Third Party: Minimum Design Loads for $uiiclings and btger SrtFuctahes, Evaluation Reports does not exceed the desive pressutres.liste8. 1211".46':8" FL4334 R9 AE 502B.pdf max nominal size. Hurricane protectwe system is A?Or.' Created by Independent Third Party: Yes required. See anchor detail DWG-MA-FLO120-05 for additional information. ... . . . . ... • • • . . . . • . ... . . . • • • • • • • • • • • •• .. • • • •• .• https://www.floridabuilding.org/pr pr_app_dtl.aspx?param=wGEVXQwtDM1'IGyvgTun'l'uaelw1-18ttto2t'12yxxFI-I1C78%2fE%3d 4/6 8/10/2015 4334.7 Florida Building Code Online Fiberglass Side -hinged Door Units - 8'-0" Glazed I/S and O/S Door w/ or w/o Sidelites Impact Rated Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.0/-50.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See anchor detail DWG-MA-FL0123-05 for additional information. Certification Agency Certificate FL4334 R9 C CAC NI005930.04.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FL0123.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 501B.pdf Created by Independent Third Party: Yes 4334.8 Fiberglass Side -hinged Door Units - Impact Rated 6'-8" Glazed I/S and O/S Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60.0/-60.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See anchor detail DWG-MA-FL0122-05 for additional information. Certification Agency Certificate FL4334 R9 C CAC NI005930.03.PDF Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL4334 R9 II FL0122.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4334 R9 AE 502B.pdf Created by Independent Third Party: Yes •• ••• • • • • • •• Back Next • • • • • • • • • •• ••• •• • • • •• Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA(,EEAefnployer. C4PYGlaht 200 .-20L3 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement • • • • • • • • Under Florida law, email addresses i re gjblic rei<prbs.olyou.dc:not w;anCyour e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contactkIse office y phone or dy tadNenal mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effeti:Cve Octobers]." 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., • • • • • • • • • • • • please click here . • • • • • • • • • • • • • • • • • ••roduct Approval Accepts: • •• •• • • • •• •• https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtA/M gTunftablWHGK o2fQyxxFHIC78%2fE%3d 5/6 8/10/2015 Florida Building Code Online •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • ••• •• • • • • • • • • • • • • • • •• • • • • • • •• • OOOOO • • • • • • • • • ••• • •• • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgMGAgTunAuaFiwHGW2fyxxF11IC78%2fE%3d eCiieck 6/6 NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation 1955 Powis Road West Chicago, IL 60185 Certification No.: NI005930.01 Certification Date: 02/17/2005 Expiration Date: 02/28/2021 Revision Date: 02/20/2015 Product: Fiberglass Impact Rated Opaque Inswing or Outswing Door w/ and w/o Sidelites (w/Wood Frame unless noted) Specification: TAS 201/202/203-94/ASTM E330 The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertiication.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI). Configuration Inswing or Outswing Glazed or Opaque Maximum Size Design Pressure Pos/Neg Water Test. Pressure Missile Impact Rated Test Report Number Drawing Number & Comments X Single I/S Opaque 3'0" x 6'8" +70/-70 2.86 psf Yes NCTL-210-3102-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FLO 120-05 X Single O/S Opaque 3'0" x 6'8" +70/-70 10.5 psf Yes NCTL-210-3102-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 XX Double I/S Opaque 6'0" x 6'8" +50.5/-50.5 - 2.86 psf - Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 XX Double O/S Opaque 6'0" x 6'8" +55/-50.5 6.0 psf/ 8.25 psf* Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FLO120-05 XO/OX Single w/Sidelite I/S Opaque Door Glazed Sidelite 6'0" x 6'8" +50.5/-50.5 2.86 psf Door -Yes Sidelite-Yes NCTL-210-3105-I Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 XO/OX Single w/Sidelites O/S Opaque Door Glazed Sidelite 6'0" x 6'8" +55/-50.5 6.0 psf/ 8.25 psf* Door -Yes Sidelite-Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FLO120-05 OXO Single w/Sidelites I/S Opaque Door Glazed Sidelites 9'0" x 6'8" +50.5/-50.5 2.86 psf Door -Yes Sidelites-Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 OXO Single w/Sidelites O/S Opaque Door . Glazed Sidelites •• • • • • •• 9'0" x 6'8" •• •• •• •• • ^ • +55/-50.5 6.0 psf/ 8.25 psf* Door -Yes Sidelites-Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 OXXO Double w/Sidelites I/S Opaque D&s Glazed Sideli •: •.: • • •:12:41c *•; i •: • • • • : • i • • • +50.5/-50.5 2.86 psf Doors -Yes Sidelites-Yes NCTL-210-3105-1 Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 OXXO Double w/Sidelites O/S Opaque Doors Glazed Sidelites • • • 12'4" x 6'8" �' • • • • •• • • +55/-50.5 6.0 psf/ 8.25 psf* Doors -Yes Sidelites-Yes NCTL-210-3105-I Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0120-05 *High Dam Threshold • • • •; • • ;• National Accreditation & Maiwgenient Instrtuio,'Inc.i4194'0eorge Washington Memorial Highway/Hayes, VA 2307 Tel: (804) 684-5124 Fax: (804) 684-5122 ••• •. . • . •••• . • •• • • .• •• ; NAMI AUTHORIZED SIGNATURE: • • • ▪ • . .• • • • . • • •• .• . • . .. .. ... • • .• ••• . • • • • •• • Luis R. Lomas P.E. 233 W Main St Danville, VA 24541 434-688-0609 rl lomasta�I rlomaspe. com Manufacturer: Masonite Report #: 504B Date: 05/21/2015 Product: Single Door 3'x6'8" Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to product described herein. These calculations comply with requirements of the Florida Building Co Drawings verification: This analysis verifies anchoring for the following drawings: DWG-MA-FLO120-05 DWG-MA-FL0130-05 DWG-MA-FL0153-06 DWG-MA-FL0122-05 DWG-MA-FL0132-05 DWG-MA-FL0155-06 DWG-MA-FL0124-05 DWG-MA-FL0134-05 DWG-MA-FL0156-06 DWG-MA-FL0126-05 DWG-MA-FLO140-05 DWG-MA-FLO160-07 DWG-MA-FL0128-05 DWG-MA-FL0151-06 DWG-MA-FL0162-07 Anchors to be qualified: 1. #10 Wood screw, for installation in wood frame substrates. 2. 1/4" Tapcon, for masonry installation Anchor capacity in shear condition: Solid members w/ & w/out gap: Fastener type: #10 wood screw Root diameter: Dr: 0.152 in • • Minimum required penetration: p: 1.140 in • • • • • • • *Cie member'. • 5idelnnm'ber thickness'. • hi!e mehber dowel bearing;trength: Side member doggl $eirri) length: • Mide 16 • •• • ••Model, Douglas Fir -Larch t,= 1.000 in F, 1, _ 4,650 psi 1.000 in Mode II • • qm = '5175§-.2 Ibs/in q 707 Ibs/in A: Per•140.1Ibs ••IA•• 707 Ibs B: • • Ko =• 2.2.00 •Ny • 2.200 C: • • Zm= • 264 Ibs • • Zits, • 321 Ibs P = • •••• Ka= • • •14.15es:n value: • Zi • 107 lbs Z= • 3 rat+on Factor: • •&,,, = e 1.6 • Allowable Design Value (ZCD): Z'= 171 Ibs/anchor •... Fastener type: 1/4" ITW Tapcon Substrate: Hollow block Edge distance: 4.00 in Edge distance: 2.00 in Actual edge distance: 2.50 in Spacing: 4.00 in Spacing: 2.00 in Actual spacing: 3.00 in Allowable Design Value (ZfAN): Z' 156 lbs/anchor 0.0008 1.07 -342.139 265 Ibs 2.2 120 Ibs (NDS 2012, TR12) substrate, and it applies only to the de. DWG-MA-FL0168-07 DWG-MA-FL0170-07 DWG-MA-FL0172-07 DWG-MA-FL0174-07 DWG-MA-FL0175-07 Gap: 9: 0.0000 in Moment arm: 0.0000 in Screw bending yield strength: Fyb = 80,000 psi Main member: Spruce -Pine -Fir Main member thickness: Main member dowel bearing strength: Main member dowel bearing length: Mode III„ A: B: C: M5= P= Ka Z= 0.00120 0.57 -212.263 46.8 in-Ibs 246 Ibs 2.2 112 Ibs FIm= 1.500 in 3,350 psi 1.140 in Mode III, Mode IV A: B: C: Mm P= Ko= Z= N.O.A. 12-0816.06 Minimum embedment: Tabulated shear design value: Z Tabulated shear design value: Z = Reduction factor: Tabulated shear design value: Z = Tabulated shear design value: Z = Reduction factor: 0.00134 0.5 -223.524 46.8 in-Ibs 263 Ibs 2.2 119 Ibs 202 Ibs 161 lbs 0.85 202 Ibs 166 Ibs 0.91 1.25 in A: 0.001689 8: 0.000 C: -93.6 P= Kb = Z. Minimum anchor capacity: 156 Ibs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors 36.38 f 1 of 2 79.25 Design pressure: 85.0 psf Zone Area (ft2) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Qty' Load (Ibs) Al 2.3 195 N/A N/A 156 2 98 OK A2 7.7 656 6.00 18.00 156 5, 131 OK 235 Ibs 2.2 107 Ibs .�vJ` �G ENS •din#',r..-_-_„ ...... ▪ 04,1 TAT OF > • c•er= /�ilONAL'•k\\ Luis R. Lomas P.E. FL No.: 62514 5/28/2015 Luis R. Lomas P.E. 233 W Main St Danville, VA 24541 434-688-0609 rllomas C1 Irlomaspe.com Manufacturer: Masonite Report #: 504B Date: 05/21/2015 Anchor Locations: 6.00 TYP. 18.19 36.38 6.00 TYP. 6.00 1345 MAX. O.C. •• • • • • • ••• • •• • • • • • 79695 • • • •• • • • • • • •• • • • •••• • •• •• • • •• • •••• • • • • • • •• •••• • •••• • • • • • • •• • • •• • • • • •••• •+ • • - 2 of 2 •••• 6.00 Note: Anchor locations indicated in this document are the minimum required for the described product exposed at the design pressure indicated herein. \\�JS D�li\, \•EN '9�i,,C e•51 -- TAT OF :co, �•• � �NF10R�P ^\ Luis R. Lomas P.E. FL No.: 62514 5/28/2015 • HURRICANE BELLEVILLE FIBERGLASS DOOR UNIT 6'-6" DOUBLE DOOR WITH / WITHOUT SIDELITES GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES USTED. 2. THIS PRODUCT DOES NOT REQUIRE THE USE OF A HURRICANE PROTECTIVE DEVICE (SHUTTERS). 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 4. PLASTICS TESTING OF FIBERGLASS FACING: TEST DESCRIPTION DESIGNATION RESULT SELF IGNITION TEMP ASTM D1929 752 'F > 650 'F RATE OF BURNING ASTM D635 0.56 IN/MIN (C-1) SMOKE DENSITY ASTM 02843 53.4% TENSILE STRENGTH. ASTM 0638 3.2% DIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 ❑❑ EIEJ EIU SINGLE DOOR UNIT) DOUBLE DOOR UNIT TABLE OF CONTENTS SHEET f DESCRIPTION 1 TYPICAL ELEVATIONS & GENERAL NOTES 2 ANCHOR LOCATIONS & DETAILS 3 ANCHORING LOCATIONS & DETAILS 20.5" MAX D.L.O. ' 149" MAX. OVERALL 36.375" MAX. ,..._ PANEL WIDTH W/ASTRAGAL FRAME WIDTH 37.5" MAX. FRAME WIDTH • . .� - MAX. FRAME HEIGHT 81.875' _ 62.675" MAX. _ 1 • 0 oq no 00 .:....4. . SINGLE DOOR UNIT LT± SITYI TTF DOUBLE DOOR UNIT W/SIDELITES ❑❑ oo. • • SINe1L (SOI; • DOOR UNIT W/SInFIITFS • • •WITH SIDIEIRE • • • • • MAX. PANEL HEIGHT 79.250" A4dBIIdImbNNY RehTiptianlb . NzooS93o �� DO %Wei ❑ ❑ DO 00 ❑❑ 00 00 DOUBLE DOOR UNIT W/SIDELITES DESIGN PRESS RATING WHERE WATER INFILTRATION PERFORMANCE IS REQUIRED TO BE 15% OF DESIGN PRESSURE C$dFIIG 1y-I . INSWING • UTSw1Nt• • l • INSWING OUTSWING OUTSWING• ( X) / •70 I +70.0 / -•70.0 , 1910 -19.0 +70.0 -70.0 +70.0 / -70.0 �(X • .0 / •5005 0 / -;A.3 41,0 -19.0 +40.0 -40.0 +55.0 / -50.5 OX or XO 75"• i850.5•/ -105 6+55.0 •' -•50. 49 10 -19.0 +40.0 -40.0 +55.0 -50.5 OXO 11 5 I V0.5 •+ 3.0 51. •+14.0 -19.0 .+40.0 -40.0 +55.0 J -50.5 OXXO 14� • +-50.5 / -50.5 +55.0 / -50.5 +19.0 -19.0 +40.0 / -40.0 +55.0 / -50.5 • High Dom Threshold Design KURT BALTHAZOR FLORIDA P.E. #56533 10 a op O U U 0 O E CD O �U UJ If) U 0LIE -(j 0 K a a to U) 3 to 3 N cn 3 W 0) Q N Z 0 V_) Cr Cr w W tal (7 w U z 2 U 0 O a 0 2 to Z 0 to 0 o 0 W U co x O 2 ate: 2/11/05 SCAM_ N.T.S. DWc. eY: SWS ant. Err: DRAWING DWG-I4A-FLOt20-05 sneer 1 OF 3 • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • 0•• • • • 0•• • • SEE DETAIL "C' DETAIL "D" 6" — — SEE DETAIL .E. 3"3* — 3' — 6" 3' Ill) 6' 3' 3' 6" 4 MORE EQUALLY SPACED ' g" — 3' � — _- _....... 1.375" Lr " INSWING THRESHOLD #10 x 2" #10 x 5/8" #10 x 5/8" #10 x 2" 0.962. j DETAIL "C" TYP. T OUTSWING THRESHOLD #10 x 1" #10 x 1" 1 1.75" T • • 6041 • • • • • • AMdelda: • • • • • •• • • • HaVieWbi By* DeleR,iewect 5/2.8 ism • ••• • • • • • • • •• • 1.0� . • • • • •• HIGH DAM 0/S THRESHOLD • • • • • 8 x 2-1/2" DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. • • 0.124" ANNEALED 0.090" SAFLEX IIG • • 0.124" ANNEALED • •• AWMWUM OR BUM SPACER •• • • • • • D0W 832 • •• • •OR EQUAL • • • • •• • •• E1 JQB WOMB • • • TYPICAL GLAZING DETAIL IMPACT RATED GLAS$ ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGAL DECORATIVE INSERT (OPTIONAL) .0124' 1EMP. /8 x 1-1/2" PHS DOW 832 OR EQUAL r DANE: 2/ 1/05 SCALE N.T.S. N Z 0 DWG. BY: SWS CHIC. BY: DRAWING No.: DWC-MA-FLO120-05 sHEEr 2 OF 3 ••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • 000 • • • • • • • • • • • • • • • • • • • • • •• •• • • SEE DETAIL "C" SHT. 2 Adderdum b NAY Ce imlb.:. NSooS93o Rained* • DO Want Sissp SEE DETAIL _ "E" SHT. 2 3" SEE DETAIL "F" SHT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON .EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 1.25" MIN i0 CI U a SEE DETAIL "D" SHT. 2 -1 7 Q w CC 0 TYPICAL MASONRY ANCHOR INSTALLATION •• ••• • • • • • 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM •• ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT" •" " OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. • ••• • • • • • • —• • •• ••• • CL• ••• •• • • • • • • • • • • • • • i`PPICAL• WOOD BUCK* ANCHOR INSTALLATION —b3` II I I I I II O O I I I I. I r 4 MORE EQUALLY SPACED y 6" n g" 1 Y- 6"— — _ ' — —I —6' 1— 3" HARDWARE SCHEDULE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. •• • • � 0•25" MAX SHIM 1"X1/2" CORRUGATED 3" FROM EACH END AND 7" OC LLAACrtiri___RTEX I CAULK CL COMBINATION COMBINATION COMPOSITE MULLION (BOXED) MULLION (BOXED) MULLION (INTEGRAL) #10X2" WOOD SCREW 6" FROM EACH END AND 12" OC (2) W00DOSCREWS ^ EACH END ACRYLIC CAULK 9 r J 0 a 3 N in V) VI N N Pjt a. N Z 0 a Z 0 V) U S a 0 0 x a Zel U 0 2 J 0 z 0 J 3 z 0 c CO 0 0 0 rn 1i w m 0 Z DATE: 2/ 1/05 S(•., r. N.T.S. OWG. DY: SWS a«. er: DRAWING NO.: DWG-MA-FL0120-05 SHEET 3 a 3 ••• • • • • ••• • • • • • • • • • •' • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • •