Loading...
RCRT-18-1693Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Permit NO. RCRT-6-18-1°693 Permit Type: 40 Yr Re -Certification Work Classification: ReCertification Permit Status: CLOSED Issue Date: 9/ 14/2018 Expiration: 01/01/2999 Parcel Number Applicant 9825 NE 7 Avenue Miami Shores, FL 1132060172290 Block: Lot: MIAMI SHORES VILLAGE Owner Information Address Phone Cell MIAMI SHORES VILLAGE Contractor(s) HOME OWNER Phone Cell Phone Fees Due 40 Yr ReCertification Fee Total: Amount $350.00 $350.00 Valuation: Total Sq Feet: $ 0.00 0 Pay Date Pay Type Amt Paid Amt Due Invoice # RCRT-6-18-67994 09/04/2018 Money Order $ 350.00 $ 0.00 Invoice # RCRT-9-18-68852 $ 0.00 Available Inspections: Inspection Type: Review Structural Review Electrical Review Building In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. September 14, 2018 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Date September 14, 2018 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ROOFING El PLUMBING ❑ MECHANICAL PUBLIC WORKS RECEIVED SEP 04 2018 C npFBC 20 �F ^, Master Permit No. K-� a T _1�G 3 Sub Permit No. ❑ REVISION ❑ EXTENSION RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: Z S- NE- 3 A VE M 1 16r# j S71 1`--t S 1 't_ 31363 - Zy 67 City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): tk 1\ Ct 1 1 1 V I `eS U I l I I !• ne#: Address: City: State: Zip: Tenant/Lessee Name: Phone#: Email: NO FFE: CONTRACTOR: Company Name: Address: \-1-0CwN.A Phone#: City: State: Zip: Qualifier Name: • Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: 0 Addition ❑ Alteration p ❑ New ❑ Repair/Replace n Demolition Description of Work: IBC 1 t2- 1 N Cf) ti\c - 67 O y .-A-1‘,S 6' Lp• , Specify color of color thru tile: - Submittal Fee $ Permit Fee $ --.b - C- CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $0 " C) "Qti�V7 (Revised02/24/2014) Bonding•Company's Name (if applicble) Bonding Company's Address City ' ' ' State + Zip Mortgage Lender's Name (if applicable) r" Mortgage Lender's Address City f State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I I ,t i' a i a -- "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." i I=y, r I A. t Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise•in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs `seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature it e Signature •1 jI OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The -foregoing instrument was acknowledged before me this day of , 20 �, by day of , 20 by •P11, scris • ovally known t• , who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: NOTARY PUBLIC: r ign• MAHARAI K. GONZALEZ aaan2 EXPIRES: November 2, 2020 FS,o?Bonded Thru Notary Public Underwriters print: eal: ********************************* ************************************************************************* APPROVED BY �I Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) T Soulimp! u.druction s Group Ltd. Co, CRECEIVED IT SEP 0 4 2018 C Opl BUILDING SAFETY INSPECTION RECERTIFICATION \\i,Sit?!.%N•tkevtii*,..m•A,:-• • - , ••• • *nem 7,,o \-k\\\ i 9825 NE 7 AVE Miami Sho i 1Qi1bAR \ * a 00..IR Y. S. RON't ft., M ASCE V.I_JaFklIDA .111 Zif462/4,/j::7:-. AUG 2 IA ?018 i-t300-9,0frfirs,,...\ , CONTACTOsOUFFR'ONTS.COM • • • • • • • • •••• • •••••• • -0 • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • TO CCMPLIA VVI-111 ALL STATE ANL) CCUNI Y RULES AND REGULATIONS grA ‘, Ac-com'A NGINEER1NG.COM • • • • .. . . . • • •••• • • • •• • LETTER OF COMPLIANCE FOR 40 YEAR BUILDING SAF•Esi lI • •• •••• • • •••• •••• • • II. BUILDING SAFTY INSPECTION REPORT FORM -- BTRuc!f )RAL •••• • •• •• .•.• III. BUILDING SAFTY INSPECTION REPORT FORM - IV. APPENDIX "G" - GENE:, €3UILDING PHt -i`0'> t-800-903-8805 • • • • • • •• • •• • CONTACT@SOUFFRONTS.COM WWW.SOUFFRONTENGINE R!NG.COM • • AUG 2 3 2018 Should you* ♦ Respect* Oscar$ 40..iffron STATE FloridaSc 246 �s% s. LOR- LETTER OF COMPLIANCE 07-16-2018 To: Miami -Dade County Building Department 11805 S.W. 26th Street, RM 149 Miami, FL 33175 Re: 9825 NE 7 AVE Miami Shores, FL 33138-2489 11-3206-017-2290 Dear, Building Official • • • • • •• • • ••. • • •••• • • • • • • •••- ••••I • • • • •••. • • •••• •• •• • • 0060 •••• • •••• • jT is letter is to inform your department that my company has visually inspected the reference:I prate, t aboye fo; structural•; nd electrical safety. The inspections were conducted in Accordance with Section 8-11 (f) of Miami Dade CQdrtt' ode . the subject property mentioned above is structurally and electrically safe for continued use undef present gooepapcy. • . • • The findings of my inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. Attached are the completed " Building Safety Inspection Report Forms" As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guaran ee for any portion of the structure. To the best of my knowledge and ability, this report represents and accurate apprai I of the present condition of the building based upon careful evaluation of observed conditions, to the extent reasona• possible. rifor ation or requirements, don't hesitate contact me at your convenience. it ION ®\,`• . AUG 2 3 2918 1-800-903-8805 CONTACT@SOUFFRONTS.COM WWW.SOUFFRONTENGINEERING.COM MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING STRUCTURAL RECERTIFICATION INSPECTION COMMENCED Date: 07116/2018 INSPECTION COMPLETED Date: 07116/2018 SIGNATURE: PRINT NAME: Juan Sou INSPECTION MADE BY: Juan Sou i ront ti iR"`J ' ront TITLE: GENERAL CONTRACTOR ADDRESS: 135 Weston Road Suite163 Weston, FI 33326 • • • • • •• • • • •••• • •• • • • •••• . • 1. DESCRIPTION OF STRUCTURE •••• •••• •••• ..•• • •.•• a. Name on Title: MIAMI SHORES VILLAGE• •• •.•. •• •••• : •••I ••••/ b. Street Address: 9825 NE 7 AVE Miami Shores, FL 33138-2489 • • • ••, •• • • • ••••, c. Legal Description: 16 53 41 3.121 AC PB 60-84 SEABOARD INDUSTRIAL CENTER W597FT OF TR 4 LESS S44FT OR 174:6-390(097 1 COC 25680-3602 05:4 14 •• • •• • • • • • d. Owner's Name: MIAMI SHORES VILLAGE • • • e. Owner's Mailing Address:10050 NE 2ND AVE MIAMI SHORES, FL 33138-2304 f. Folio Number of Property on which Building is Located:11-3206-017-2290 g. Building Code Occupancy Classification:8000 COMMUNITY FACILITIES h. Present Use:8940 MUNICIPAL : MUNICIPAL i. General Description: Property currently used for recreation purposes ( 8000 COMMUNITY FACILITIES) As per Miami -Dade County records the inspected building structure was built or completed in 1968, giving the structure an age of 50 years old. The buildings is one continuous structure with a footprint of 4,618 Sq.Ft . Addition Comments: To add on, it has a lot size of 11,045 Sq.Ft with on -site parking for cars . A001ill //Ei 1. .,,I1R --GE, f- e;:). �_i -, 1 \l y A •.. ACa • • • • • • ., • AUG 2 3 2018 j. Additions to original structure: NO ADDTIONAL STRUCTURES FOUND 2. PRESENT CONDITION OF STRUCTURE •. •. •_ • a. General alignment (Note: good, fair, poor, explain if significant) •..' •• . •� •• • • • , ••�••• 1. Bulging Fair • 2. Settlement Fair •.... • •..... • •••• 3. Deflections Fair • • •• 4. Expansion Fair • •• •• • • • •••••• 5. Contraction Fair • • •• b. Portion showing distress (Note, beams, columns, structural walls, floor, roofs, other) All areas during our inspection were found to be in Fair condition for a building of this age. c. Surface conditions — describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration and stains. The surface conditions were thoroughly inspected for deformations,cracking,spalling ,peeling, moisture,stains and other harmful factors. Favorably, none of the inspected elements had any significant damage on the surface. ,,tiiliik,, ORSoi-,. d. Cracks — note location in significant members. Identify crack size as HAIRLINE if barely discerniblf;fileP I�s3,than mm in width; MEDIUM if between 1 and 2 mm width; WIDE if over 2 mm. ,Q; .,, . «... ,1.z.'.:: , a ,4..4 : 41.1)4. • During our inspection we looked for all types of cracks and deterioration on or near significant struc 1 members, .. Satisfyingly, at the time of our inspection the visible areas were vacant from cracks,deteriorftion 8V " filar facto t. e. General extent of deterioration — cracking or spalling of concrete or masonry, oxidation of metals; rot or borer attack in wood. The general extent of deterioration on the subject property is Light for a property of this age. f. Previous patching or repairs During our inspection of the subject property we noted some minorpatching and repairs which is considered • normal for a building this age. g. Nature of present loading indicate residential, commercial, other estimate magnitude. COMMERCIAL • • • • • • 3.INSPECTIONS ' •' ' ' a. Date of notice of required inspection • _ • • 000, • r "0414 . •..• b. Date(s) of actual inspection 07/16/2018 • ..•• ••.. • •.•. ..•r • •..•r c. Name and qualifications of individual submitting report: • •• • •• 000 • •••• • ""' ••••r Oscar Y. Souffront P.E. • • •• •• • _• . •. •0..1 d. Description of laboratory or other formal testing, if required, rather than manual or visua'I.proce1ures .. • •. •• :•••r N/A • • • .. ' e. Structural repair -note appropriate line: 1. None required X 2. Required (describe and indicate acceptance) 4. SUPPORTING DATA a. sheet written data b. X photographs c. drawings or sketches AUG 2 3 2018 5. MASONRY BEARING WALL = Indicate good, fair, poor on appropriate lines: a. Concrete masonry units Fair b. Clay tile or terra cots units Fair c. Reinforced concrete tie columns Fair d. Reinforced concrete tie beams Fair e. Lintel Fair f. Other type bond beams None Found. g. Masonry finishes -exterior Fair 1. Stucco x 2. Veneer 3. Paint only ..••. :::' 4. Other (describe) • • • • • • • • • h. Masonry finishes - interior Fair •••• •••• • •••• 1. Vapor barrier •• •• •••• • •••• 2. Furring and plasterX •••• 3. Paneling • .• • .. • • •• • • • 4. Paint only 5. Other (describe) i. Cracks 1. Location — note beams, columns, other NOT APPLICABLE. 2. Description j. Spalling 1. Location — note beams, columns, other NOT APPLICABLE. 2. Description k. Rebar corrosion -check appropriate line ,0\4\sitiR,Sai/f.. ,_,. 1. None visible X \�-y\CEN • •Q ♦,. i.� s 2. Minor -patching will suffice .` O / Y ?t1:4):i 62 ', -'4 3. Significant -but patching will suffice Y = -C i , Ack: ♦ qe� et Oh At #'' AUG 3 2018 • • • • • • • • . • • 4. Significant -structural repairs required I. Samples chipped out for examination in spall areas: 1. No 2. Yes — describe color, texture, aggregate, general quality 6. FLOOR AND ROOF SYSTEM a. Roof Fair 1. Describe (flat, slope, type roofing, type roof deck, condition) Fair condition: Hip Roof Type ,Roof has no signs of leaks, Good Condition ...• • • •• .••. ..•.• • .• • • • 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equip ent andFppjiftion of...: support: • .•.• •.•• • Fair Condition: HVAC, • ..•. • • . •.• •.• .... 3. Note types of drains and scuppers and condition: • • • .• • • • Gutter drainage anatomy was complete and in working condition. •• •' • ' b. Floors stems • system(s) Concrete Slab " ' 1. Describe (type of system framing, material, spans, condition) Fair Condition: Slab on Grade , Concrete Slab 4"-6" In depth found. Catwalk concrete in fair condition. c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members. During inspection NO attic areas were exposed for viewing. \\Miliht4, 7. STEEL FRAMING SYSTEM `-: 43—,�,SGEtisk'.;'y ✓, F a a. Description ::: 0 6 * r�. 46� s .., s -A- ' ". A Steel framing was not found on the subject property as a result this section. ^ * . t� 'I= OF [;I � AT ;' . • • • • • • • • • • b. Exposed Steel- describe condition of paint and degree of corrosion NA c. Concrete or other fireproofing — note any cracking or spalling and note where any covering was removed for inspection No Cracking or spalling visble. d. Elevator sheave beams and connections, and machine floor beams — note condition: • • .••• • •••• • • • ••• • • .. • • ••••• • • •••• • .••• .••• • ...• • •.•• • •••• • • . • •. •• .... .... 8. CONCRETE FRAMING SYSTEM • a. Full description of structural system Subject property walls all around are made of CNLIJ blocks argistipport all • • • --004 .. • . • • tie beams found on site, foundation found is 4-6 inch concrete on grade. • • • • b. Cracking 1. Not significant x 2. Location and description of members affected and type cracking Supporting walls and foundation c. General condition Overall the concrete framing system was found to be in fair conditon. d. Rebar corrosion — check appropriate line 1. None visible X 2. Location and description of members affected and type cracking 3. Significant but patching will suffice bf ����,\`M RISO r/ 4. Significant — structural repairs required (describe) `\�\ ¢yP- F G',i e. Samples chipped out in spall areas: CoDV-0' '. Z 1. No X —'f,: iT .• , ��' -' 2. Yes, describe color, texture, aggregate, general quality: ��1n �� STA EOF , ; -n < • AUG 23 018 9. WINDOWS a. Type (Wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) Fixed aluminum style windows. Fair Condition overall b. Anchorage- type and condition of fasteners and latches Typical manufacture recommended fasteners c. Sealant — type of condition of perimeter sealant and at mullions: FAIR CONDITION: Well sealed d. Interiors seals —type and condition at operable vents FAIR CONDITION:Silicone seal e. General condition: FAIR CONDITION: Fixed Aluminum style windows installed at subject property in. .... . . .. . • .. • . . 0000 • • • 10. WOOD FRAMING 0... • a. Type — fully describe if mill construction, light construction, major spans, trusses: • ' ' 00410 • 000404 Does Not Apply to subject property. .. .. .... 00001 b. Note metal fitting i.e., angles, plates, bolts, split pintles, other, and note condition: • • • • . 1 ....1 • .. . . . .. • . • . .. • ..... • c. Joints — note if well fitted and still closed: d. Drainage — note accumulations of moisture e. Ventilation — note any concealed spaces not ventilated: f. Note any concealed spaces opened for inspection: js:I m: rtc:1/10/2014:40yea rrece rtificationsystem • • • • • • • • AUG 2.3 2018 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING ELECTRICAL RECERTIFICATION INSPECTION COMMENCED Date: 0711612018 INSPECTION COMPLETED Date: 07116/2018 INSPECTION MADE BY: Juan Souffront SIGNATURE: PRINT NAME: Juan Souffront TITLE: GENERAL CONTRACTOR ADDRESS: 135 Weston Road Suite 163 • • ...• • . • •. • • • •• • • • • • • .•• Weston, FI 33326 • • DESCRIPTION OF STRUCTURE 6a Name on Title: MIAMI SHORES VILLAGE • • • • • • • • • • • .. •.. •••••• • • • • • • • ••• ••• • • • • • • • • • • • •. • ••••• • • • . i• • • • • • • lb. Street Address: 9825 NE 7 AVE Miami Shores, FL 33138-2489 •• • •• • • • c. Legal Description: 16 53 41 3.121 AC PB 60-84 SEABOARD INDUSTRIAL CENTER W597FT OF TR 4 LESS S44FT OR 17486-3925 01971 COC 25680-3602 05 20071 d. Owner's Name: MIAMI SHORES VILLAGE e. Owner's Mailing Address: Folio Number of Property on which Building is Located: 11-3206-017-2290 !g. Building Code Occupancy Classification: !h. Present Use: 8940 MUNICIPAL : MUNICIPAL i. General Description, Type of Construction, Size, Number of Stories, and Special Features Additional Comments: Property currently used for recreation purposes (8000 COMMUNITY FACILITIES) As per Miami -Dade County records the inspected building structure was built or completed in 1968, giving the !structure an age of 50 years old. The buildings is one continuous structure with a footprint of 4,618 Sq.Ft . ;(adjusted Area) ST AUG 2. 3 2018 GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 1. ELECTRIC SERVICE 1. Size: 2. Phase: 3. Condition: Comments: 2. METER AND ELECTRIC ROOM Amperage Three Phase Good ( 300 ) Fuses ( X ) Single Phase (X ) Fair Breakers Needs Repair Electrical service cables are in good condition and working properly. . Clearances: Good ( X Fair ( • •. . .._• • ..• •......_•.• ............ . •••• ( 300 ) • • • .... •••• • • • • •••• • • • • • • • • • Requires Correction . ( . ) • • Comments: Good Clearance as per NEC 110.26 3. GUTTERS Location: Good ( X Taps and Fill: Good ( X Comments: Gutters free of debris and damage. Requires Repair Requires Repair ( ( \\\\\MIRE 5 i ' /4 ;fi a --..ice. cs 0�9" .r�.: 46. tY r d Y :::::3;1394:1\f'is6: .A� 1 -14f:89ts1 AUG 2 3 2018 4. ELECTRICAL PANELS l Location: 2. Panel #( 2 Good ) Needs Repair Good Good ( X 13. Panel #( 5. Panel #( Good Good ( Good ( Needs Repair ) Needs Repair ( ( ( • . Needs Repair ) Needs Repair Needs Repair ( ( ( Comments: Electrical Panels inspected were in working condition . 5. BRANCH CIRCUITS: 1. Identified: Yes (X ) Must be identified ( 2. Conductors: Good ( X ) Deteriorated Comments: ( .. . .... . . .... • •• • • • •••• •••• • • . • •• • • • .• ••• •••• •••••• • • • • • • • .• • __; • • • • • • • • • • • • • •. • Must be replaced • • • OW //ice 6/ N ,• AUG 2, 3 2018 6. GROUNDING SERVICE: Good (x ) Repairs Required ( Comments: Grounding service for subject property was checked with a grounding inspection instrument. Instrument was tested in main key points of the property and was determined that the property's grounding system is in fair condition. 7. GROUNDING OF EQUIPMENT: Good (X ) Comments: NO. 302U, UNIVERSAL GROUND ROD CLAMP COPPER -COPPER -CLAD -OR STAWLESS STEEL—GROUNDYR : Gad : CONDITION Repairs Required • .. .• . . ( .••• •••: - • •. • • . •...) • 41,11.41.11.5014* 8. SERVICE CONDUITS/RACEWAYS: Good (X ) [Comments: Rigid metal conduit (RGS) were found to be e main type of Raceways. Repairs Required • • • • • • • • • • • • ._ • • • . .. • •.• • • . ••1. • • • • • • � • t .; . •..•.. • • ( [9. SERVICE CONDUCTOR AND CABLES: Good (X ) Repairs Required Comments: Service conductors identified and found to be in Good Condition. .17 AUG 2 3 2018 110.. TYPES OF WIRING METHODS: Conduit Raceways: Conduit PVC: NM Cable: BX Cable: Good Good Good Good 111. FEEDER CONDUCTORS: Repairs Required Repairs Required Repairs Required Repairs Required Good ( X Repairs Required ( •• • . •.•• •• • .•• • •. •••• Comments: Feeder Conductors identified and found to be in Good Condition:. 12. EMERGENCY LIGHTING: • • • • .••• .•.• • • • • • • •••• •••• •••..• •• •• Good (X ) Repairs Required • • • •••• • •••• .•.•• •••••. •• •••••• • • • • • • • • ..•.•• •• • •. • • • • •• • •• • x ( Comments: Emergency Lighting Unit with 2 Lights and Battery Backup (120V) tested and working at time of inspection "Exit "signs "are internally illuminated. 13. BUILDING EGRESS ILLUMINATION: Good (X ) Comments: Good Condition. Exit lights in place working. Repairs Required ( 04111RIIISZ / i e r c )F ; 2l � Oat e; AUG 2. 3 2018 14. FIRE ALARM SYSTEM: Comments: Good Fire alarm system found in working condition. Repairs Required 115„ SMOKE DETECTORS: • • • • • . . . • • • • • • • • • ( ••••) • • • • • Comments: Working smoke detectors we found in working condition at thetiffie of iffspection. • ....• .• Good X) 116. EXIT LIGHTS: Comments: Visible and working Good (X ) 17. EMERGENCY GENERATOR: n ,heiraa A. A. Comments: N/A Good Repairs Required Repairs Required Repairs Required • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • AUG 2 3 2018 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS: Require Additional Comments: N/A Good Repairs Required r 19 OPEN OR UNDERCOVER PARKING GARAGE AREAS AND EGRESS ILLUMINATION: N/A Require Additional Comments: N/A Good 20. SWIMMING POOL WIRING: Good Comments: N/A ( ) r. WIRING TO MECHANICAL EQUIPMENT: Comments: N/A Good (_) • • • • • • • • ••• • • • • •• . • II • • • • • • • • Repairs Required Repairs Required • ) • • • • •••• • • • • • • • IOW •••• • • •-••••-•-e— "riltAir0 64 • • • • • • • • • • • • • •••••••.- • • • • • • • • • • • • *4 • • • • •••••• •• • • ,s, • •• ▪ • Repairs Required t 22. ADDITIONAL COMMENTS: SD: rs:vc:mb:js:rtcl :8/5/2011:40yrtrackingsystem • • • • •••• • • • •• • • •• •••••• •••• • s• • •••• •••• • s • • • • i ••.. •••• _m....__ -_...__ ...+,..i • •• •• •••• • • • • • • • i. • • • •• • •• • • • • CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS REQUIREMENTS IN CHAPTER.8C OF THE CODE OF MIAMI-DADE COUNTY DATE: 07/16/2018 Re: Case No. Property Address: 9825 NE 7 AVE Miami Shores, FL 33138-2489 Building Description: 8940 MUNICIPAL : MUNICIPAL The undersigned states the following: . . . .. . • .. • • • ••• • I am a Florida registered professional engineer or architect with an active license. On O746/2018...i inspected the parking lots servicing the above referenced building for compliance with section 8C-eared. determined the following (check only one): .... .. .. .... r The parking lot(s) is not adjacent to or abutting a canal, lake or othe( bodypf water. • . . The parking lot(s) is adjacent to or abutting a canal, lake or other body of water of •. • parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. r The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that comp`im iJh1,,Section 8C-6 of the Miami -Dade County Code. I have advised the prone. . , hatihe/she must obtain a permit for the installation of the guardrail aOli b -i 5 c'4✓ irefi:�flspection approvals to avoid enforcement action. `��\i �' b S .:' =, - !;`Stgbatui of/Aro riect• or- .6: o Ar .- w W rjR ee`4 j OI A_L \:\Y ` 5 AUG 2 3 2018 Oscar Y. Souffront P.E (Print Name) CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY LIGHTING OVERSPILL IN SECTION 33-4.1 OF THE CODE OF MIAMI-DADE COUNTY Date: 07/16/2018 Re: Case No Permit No.: NO PARKING LOT ON PROPERTY 1 CITY CURB PARKING ONLY. Property Address: 9825 NE 7 AVE Miami Shores, FL 33138-2489 .... • • Building Description: 8940 MUNICIPAL : MUNICIPAL • • • • • • • ...• 1. I am a Florida registered professional engineer or architect with arl ac:in license, ...• .... • • 2. On 07/16/2018 at 12:OOPM, I measured the level of illumination ig ilarkingeliEss • • • serving the above referenced building. illumination in the •... • •.: • • 3. Maximum 2 foot candle per SF, Minimum 1 foot canoe Pe; SF, Minimum to •' Maximum ratio 2 1 foot candle 1.00 average per • • • • •• • •• • • • .• 4. The level of illumination provided in the parking lot (s) meets the minimum sffndards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. 011I III//, ,e .t NAIR 5. The level of oudoor lighting overspill meets the limitaf »S, - - : + 6d,iriySection 33-4.1 of the Code of Miami -Dade County. c '�, ° a "<.e� p ! Y A/ .� ` ; _f: �/ w /oyi ect .t aineer AUG232018 Oscar Y. Souffront P.E (Print Name) a Construction Group Ltcl. Co. Cre11.1"0/ ( ,)+1701,,q,m- ,-tintpa+t), '*.....10k-ote.' .01 itIthori:olif,i, ,-'4.1(0417 6W/tit trw %coo,' impotht•t• (1,( 1,5(MAN,:i LEGEND FOR COMMENTS RR = REPAIRS REQUIRED. SS = SPALLING SPOT WD = WATER DAMAGE AOX= AGGRESIVE OXIDATION APPENDIX "G" GENERAL BUILDINGPHPIP. -800-903-8805 F'•'•:, • ' • •• • CONTACTsOUFFRoNTs COM WWW.SOUFFRONTENGINEERING.COM • •• • I • • • • )* • • • • • • • • • • • • • • • • • AU2 3 2018 G Arlenis Silvera From: Arlenis Silvera Sent: Wednesday, June 27, 2018 12:25 PM To: Elizabeth Keeley Cc: Ismael Naranjo Subject: Building Re -Certification Attachments: 3547_001.pdf Hi Lisa, See attached the required building re -certification notice for: 9617 Park Dr. 9825 NE 7 Ave 10200 Biscayne Blvd 10000 Biscayne Blvd Best Regards, Arlenis Silvera Permit Clerk Supervisor Miami Shores Village 10050 NE 2 AVE Miami Shores, FI 33138 305-795-2204 www.miamishoresvillage.com From: mfp@msvfl.gov <mfp@msvfl.gov> Sent: Wednesday, June 27, 2018 12:10 PM To: Arlenis Silvera <SilveraA@msvfl.gov> Subject: Miami Shores City Hall Canon Scan 1 Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice of Required Building Recertification Date: June 21, 2018 To: Owner Miami Shores Village 10050 NE 2 Ave Miami Shores, FL 33138 Re: Mandatory 50 Year Re -certification 9825 NE 7 Ave Miami Shores, FL 33138 Dear Owner: According to the information provided by the Miami Dade County Property Appraisers office the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8-11, the subject property must be inspected and re -certified by a Florida license architect or engineer. A building re -certification report signed and sealed by the Florida license engineer and or Architect along with the required fees shall be submitted to this office within sixty (60) days of receiving this notice. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305-795-2204. Sincerely, p 9 Ismael Naranjo, B Building Director. Email: bo(&msvfl.gov Certified Mail # Property Search Application - Miami -Dade County E Summary Report Property Information Folio: 11-3206-017-2290 Property Address: 9825 NE 7 AVE Miami Shores, FL 33138-2489 Owner MIAMI SHORES VILLAGE Mailing Address 10050 NE 2ND AVE MIAMI SHORES, FL 33138-2304 PA Primary Zone 8000 COMMUNITY FACILITIES Primary Land Use 8940 MUNICIPAL : MUNICIPAL Beds / Baths / Half 0/0/0 Floors 1 Living Units 0 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 4,618 Sq.Ft Lot Size 11,045 Sq.Ft Year Built 1968 Assessment Information Year 2017 2016 2015 Land Value $103,602 $103,602 $103,602 Building Value $160,014 $152,394 $139,648 XF Value $16,478 $16,696 $14,484 Market Value $280,094 $272,692 $257,734 Assessed Value $280,094 $272,692 $257,734 Benefits Information Benefit Type 2017 2016 2015 Municipal Exemption $280,094 $272,692 $257,734 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description AMD PL MIAMI SHORES SEC 4 PB 15-14 ALL BLK C LOT SIZE 11045 SQUARE FEET Page 1 of 1 Generated On : 6/20/2018 Taxable Value Information 2017 2016 2015 County Exemption Value $280,094 $272,692 $257,734 Taxable Value $0 $0 $0 School Board Exemption Value $280,094 $272,692 $257,734 Taxable Value $0 $0 $0 City Exemption Value $280,094 $272,692 $257,734 Taxable Value $0 $0 $0 Regional Exemption Value I $280,094 $272,692 $257,734 SO Taxable Value $0 $0 Sales Information Previous Sale ; Price, OR Book -Page Qualification Description The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/propertysearch/ 6/20/2018