Loading...
REV-18-3062BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED OCT 04 2018 BY FBC 20 Master Permit No. R F- G-13 -1(0 05 Sub Permit No. V ' %ae ❑BUILDING ❑ ELECTRIC ROOFING %REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP. ,. CONTRACTOR DRAWINGS JOB ADDRESS: l.50 G City: Miami Shores County: Miami Dade Zip: 3 3t 3s Folio/Parcel#: I% 5,1-0 too lb Q 0 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): ' IeFCInp (, ,oi fl• CA.4O Address: 1rjo f)E 94 g+ City: Midi'1 i 6Llorts Phone#: giCO - LJ0 State: FL Zip: 3 3 3? Tenant/Lessee Name: Phone#: Email: COCONTRACTOR: Company Name: L COY+CS CA.M. , CA O n 6UkeS hone#: 3 ` 4 ib a'3cS 94 Address: /(J IS iU li q W I V City: Hi A WA iv 1-1 State: F/ zip: 3 3 (� /.5 Qualifier Name: iv V Co a fe 5 Phone#: A 5- I/5 hi - t`pf State Certification or Registration #: C- CC / 330 2 9 % Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 4371, S"b' Square/Linear Footage of Work: 6 B �P Type of Work: ❑ Addition ❑ Alteration n New ❑ Repair/Replace ❑ Demolition Description of Work: Cha,45 e o f TI i e, fropet C a te, Malt 4 u -l-o `13orGk '6Ctfc n Ma goo CO>nc rule 'oo4- Tt Vt.. Specify color of co/o'r thru"tile:'. `:r= . y'r Submittal Fee $ Scanning Fee $ Technology Fee $? • Structural Reviews $ Permit Fee $ Radon Fee $ k tit CCF $ "IrCO/CC $ DBPRI$ . U� ` Notary$ Training/Education Fee $ ? • vl C SZS• S. 25 Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all 'applicable laws regulating construction and zoning. . LC �.) {"; i ;; 'C "WARNING TO 'OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY c t t . is ,d' , t RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY: -',IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR:NOTICE, OF, COMMENCEMENT." • Notice to Applicant: As a condition to the issuance of a building permit with an estimated:value exceeding:$2500, the'applicant must promise in good faith; that a copy of the notice of • mencement:and construction lien law brochure will be"delivered to the person whose propert is s bjec, •tachment. Is , a c rti 'ed copy of the recorded notice of commencement must be posted att the fob site for the first ins• •c\\occurs seven (7) doer the building permit is issued. In the absence of such posted notice, the inspection will no. bpand • reinspectioill be charged. .� The foregoing instrument w s acknowledged before me this 0.11 day of 8(6p* 11.4 e.JR , 20 1 8 , by 541-egl NO., CAR N i A (b , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: / �! Print: / 1ff4 d Co addLe' Seal: •--+_'vim •p • •1•t �ryy Bonding Company's Name (if applicable) Bonding Company's Address r 1— City F!- r State Zip 1 —a• tia _ w 1�9.� Mortgage Lender's -Name (if applicable) Mortgage Lender's Address Citye� ;i , (•��.I �� � State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to'`meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC t..: t- a°.0 .......4, AMBER CORDOBA * * MY COMMISSION # GG 063399� -1i • j EXPIRES: January 23, 2021 F FOF AP.. _. q•.•+.. _ ******************************1*********************************************** ***************************** Signatu r•1 CONTRACTOR The foregoing instrument was acknowledged before me this C day of S k . t-lao P_At , 20 t , by ist A 1.• / Co R l e' S ; who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: • Print: � H, as APPROVED BY Seal: • Plans Examiner AMBER CORDOBA * MY COMMISSION # GG 063399 t . .. , ..�` EXPIRES: January 23, 2021 ` �OF F�0 .._..... Structural Review rt tY Poe�,o Zoning • Clerk (Revised02/24/2014) A� �® CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DDIYYYY) 10/3/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Presidential Insurance Services, LLC 2665 South Bayshore Drive # 707 Y Miami, FL. 33133 CONTACT Jeff Lampert PHONE No. Exth 305-423-0350 iac, No): 305-423-0351 Eau+aL eff Insurance uotelive.com ADDRESS: � � q INSURER(S)AFFORDINGCOVERAGE NAIC# INSURERA: Preferred Contractors Insurance Company INSURED L Cortes Construction Service, LLC 18786 NW 79th Way Hialeah, FL. 33015 INSURER B : INSURER C : INSURER D : INSURERS: INSURER F : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSD SUBR WVD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) LIMITS A X COMMERCIAL GENERALLIABILITY PC-294971 9/28/2018 9/28/2019 EACH OCCURRENCE $ 1,000,000 DAMAGE TO PREMISES (EaENTED occurrence) $ 50,000 CLAIMS -MADE X OCCUR MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L X AGGREGATE POLICY OTHER: LIMIT APPLIES JEa PER: LOC PRODUCTS-COMP/OPAGG $ 1,000,000 $ AUTOMOBILE UABILITY ANY AUTO OWNED AUTOS ONLY HIRED SCHEDULED AUTOS NON -OWNED AUTOS ONLY COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ UMBRELLA LIAB EXCESS LIAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ $ DED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANYPROPRIETORIPARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y / N N / A PER STATUTE OTH- ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) Roofing and General Contractor. CERTIFICATE HOLDER CANCELLATION Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FL. 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Tile Roof System e-F 18- oo3 NI IAMMADE COUI'f "Delivering Excellence Every D Roof System Manufacturer: Miami -Dade County HVHZ Electronic Roof Section D Tile Roof System ,,t BORAL Notice of Acceptance Number (NOA): 16-0711.01 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P1: -39.1 P 2: -68.1 P 3: Maximum Design Wind Pressures, (From the NOA Specific system): 29.3 psf RECEIVED Permit Form OCT 0 4 2018 BY F' ifi ..li" embly components. If a component is not required. insert not applicable (n/a) in the text box. ?is Roof Slope: Roof Mean Height: "/12" 14 Method of Tile Attachment: ft. --Adhesive, 2 Small Paddy Polyfoam Poly' Alternate Method of Tile Attachment per NOA: N/A Drip Edge Size & Gauge: Drip Edge Material Type: Drip Edge Fastener Type: Hook Strip/Cleat gauge or --3" face 26 ga.-- --Galvinized Metal -- Deck Type: --5/8" Plywood -- Optional Insulation: • f POLYISO INSULATION • •. Optional Nailable Substrate:.:.. --• - • • • .... N/A ...• .... . • .... Optional Nailable Substrate Attachment!. • N/A • . . ..._......... _..._ .....•___. • Basesheet Type: • • • •. • • .• . • . . Fastener Type for Basesheet Attachment: 1 5/8" TIN CAP I 1 1/4" RS NAILS Tile Underlayment (Cap Sheet ) Type: #90 ASTMD Tile Underlayment Attachment Method: HOT MOP ASPHALT 1 1/4" RS NAILS Tile Profile: weight: P E M iTl- ;' BARCELONA 900 CONCRBTE ROOF TILE --n/a- vliami Shores Villageu BY DATE APPROVED ZONING DEPT BLDG DEPT 16(4 0 S SUBJECT TO COMPLIANCE WI FH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS • .• • • - 3oCo2 Section E Miami -Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P 3: -39.1 -68.1 -100.7 x? x? x? 0.301 0.301 0.301 11.77 20.50 30.31 - Mg: - Mg: - Mg: 7.00 7.00 7.00 = Mr1: = Mr2: = Mr3: 4.77 13.50 23.31 s 29.3 29.3 29.3 Method 3 "Uplift Based Tile Calculations Per RAS 127" NOA Mf NOA Mf NOA Mf • • • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greatertltan df equalOttefj values, for• each area of the roof, then the tile attachment method is acceptable. • • • • P1: P2: P3: xl:= xl: xl: x w: x w: x w: - W: - W: x cos 0: = Fr1: x cos 0: __' = Fr2: x cos 0: = Fr3: • • • • Where to Obtain Information to complete tile calculations ••� • • • •• • • • • • • • • • • • T? 3I F' • • • N6A F' • • • • • •• • • • • •• • • • • • Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height . H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier X. Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I = length w =width Product Approval (NOA) :c 1 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www. miamidade.4rov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Conlxol Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve Jig right to ha 'fh1S • product or material tested for quality assurance purposes. If this product or material fails to perfo'rniin the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediate+raadce, modifjn,.or suspend the use of such product or material within their jurisdiction. RER reserves the righttetevoke this acceptance,• if it is determined by Miami -Dade County Product Control Section that this product or materjal•Patls to me2t'the• • requirements of the applicable building code. "" "" This product is approved as described herein, and has been designed to comply with the FlorTdari�ilding Code" including the High Velocity Hurricane Zone of the Florida Building Code. • DESCRIPTION: Barcelona 900 Concrete Roof Tile • • . • • • • • • •• • .. • •• • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andfol►owing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0222.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Barcelona 900 Trim Pieces Length = 17" TAS 112 Width = 13" Type — 1 a Yz" thick Length: varies Width: varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL 2.2 SUBMITTED EVIDENCE: Test Agency Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies MANMADE COUNTY APPROVED TAS-112 Test Identifier 7161-03 Appendix III 7161-03 Appendix 11 P0402 Letter Dated Aug. 1, 1994 P0631-01 Product Description • • High profile, interloe1ipg, One-piegp.;S' shaped, high-pressure extrudedicrete ropf tiL equipped with three fail ioules. For direct deck. or battened nail -on, •mechanically fegened, mortar set or adhesiveM•applicatieMs.• .... Accessory trim, boosted•darcelone, 58ncrete roof pieces for use ai hills; rakes, ridges and valley terminations rpanutactured:ftr eaeh tile profile. • • • .. . Test Name/Report Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108(Nail-On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) . . . . ..• . Date Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 July 1994 • . NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 2 of 7 Professional Service Industries, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida 3. LIMITATIONS: IC-1320-94 Physical Properties TAS 112 25-7688-3 25-7688-10 25-7688-5 25-7688-4 520111-3 520191-2-1 Calculations Evaluation Calculations RT0617.03-16 TAS 101 (Adhesive Set) TAS 101 (Mortar Set) Static Uplift Testing TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Static Uplift Testing Dec. 1998 TAS 101 March 1999 Aerodynamic Multiplier 09/01/16 Restoring Moments Due to • 09/91 / 16 Gravity • • • • Feb. 1995 June 1996 July 1996 June 1996 • TAS 112 •• • Q61:9/16 • • .... .••• • •... .•.• 3.1 Fire classification is not part of this acceptance. • • • • • • • 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance MUtth•TAS 106M ' • required, refer to applicable building code. . • . • 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterl±ytest in• accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Dep•aortmpt of kguloatory and Economic Development — Product Control Section for review. • • • .• . 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. • • • NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 3 of 7 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 • • • • . . Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf) .• ' • ".. ' Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12:.. '....' . 7;;i4" or •greater . Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens ' 13fdd '•Deck Batter=S' • • • • •Direct'' Deck •' 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 :'6b"tt 5.76 • 6.42 • • • •• • ••• • .• Table 4: Attachment Resistance Expressed as a Moment - Mf RHO): - •. •• for Mechanically Attached Systems • • • • Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 MIAMI-DADE COUNTY APPROVED NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 4 of 7 • • Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" tile headlap and fasteners are located a min. of 2'/z' from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Adhesive' 29.32 1 See manufactures component approval for installation requirements. ' 2 TILE BONDTM Roof Tile Adhesive; Average weight per paddy 10.7 grams. • •'. ' ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per pad ' 8 Prams."". • • • • Table 7: Attachment Resistance Expressed as a Moment - Mf (fklpf) „� • for Single Paddy Adhesive Set Systems '••.•• '••••. • ., Tile Profile Tile Application Itlfidirflim Attablffient " '• '•Resistance .' •• Barcelona 900 ICP Adhesives Polyset AH-160 : • : 66.53 41 ICP Adhesives Polyset AH-160 . •. 38.74••••• ;, 3 Large paddy placement of 63 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives POlystt AH-1,30'. • _ • 4 Medium paddy placement of 24 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH'160' Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set5 24.5 6 See specific mortar manufacturers Notice of Acceptance MIAMI DADE COUNTY APPROVED NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 5 of 7 • • •• • .•.• • • • •.•• • .••• • 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS . • • 6.1 Application for building permit shall be accompanied by copies of the following...: •••• . • 6.1.1 This Notice of Acceptance. • •••• 6.1.2 Any other documents required by the Building Official or applicable bui7ditlg'cbde in order to properly evaluate the installation of this system. ."". • •"' • •••• •••• • • MIAMIDADE COUNTY APPROVED • •• •• •••• • • . • • • • • •• • • . • • •• • • •• • NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 6 of 7 . PROFILE DRAWING NAIL HOLES 17" UNDERLOCK OVERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED 13" 3 5/8 " . • • • • •• • •.•• • •• . • • . •••• •••• • • • • • . •••• ...• • • •••. • • • •• •• •••• • • • • • • • • • • • • • • .• • .• • • • • • • •• • NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 7 of 7