ELC-18-1041Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Iss t Permit NO. E LC-4-18-1041 Permit Type: Electrical - Commercial Work Classification: Sign Permit Status: APPROVED Date. 4130/2018 Expiration: 10/27/2018 Parcel Number Applicant 11300 NE 2 Avenue Number: Garner Buildin 1121360000050-25 Miami Shores, FL 33138-0000 Block: Lot: BARRY UNIVERSITY INC Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) KEMP SIGNS & SERVICE INC Phone (561)840-6382 Cell Phone Valuation: Total Sq Feet: $ 250.00 0 Type of Work: FINAL ELECTRICAL FOR 2 ILLUMINATED Additional Info: Classification: Commercial Scanning: 1 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $0.60 $2.25 $2.00 $0.20 $150.00 $3.00 $0.80 • $158.85 Pay Date Invoice # 04/19/2018 04/30/2018 Pay Type ELC-4-18-67226 Check #: 6224 $ 50.00 $ 108.85 Credit Card $ 108.85 $ 0.00 Amt Paid Amt Due Available Inspections: Inspection Type: Final Review Electrical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I ssume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for EL .,CT L, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AF construction an I certify t(lat all the fore Fuj�erm re, I aut Authoriz gnatur Ding information is accurate and that all work will be done in compliance with all applicable laws regulating e abov -named contractor to do the work stated. :Owner / Applican l,V Contractor / Agent April 30, 2018 Date Building epartment Copy April 30, 2018 1 Miami Shorcs Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION *BUILDING ❑ ELECTRIC ❑ ROOFING PLUMBING ❑ MECHANICAL PUBLIC WORKS RRCET\J APR 19 2018 FBC 201 -� Master Permit No ,l v !8 ` 1 09 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ CHANGE OF ❑ CANCELLATION CONTRACTOR JOB ADDRESS: Barry University - 11300 NE 2nd Avenue - Garner - Dunkin Donuts ❑ RENEWAL ' ❑ SHOP DRAWINGS City: Miami Shores Folio/Parcel#: 11-2136-000-0050 Occupancy Type: County: Load: Construction Type: OWNER: Name (Fee Simple Titleholder): Barry University Address: 11300 NE 2nd Avenue Miami Dade Zip: Is the Building Historically Designated: Yes Flood Zone: NO X BFE: FFE: Phone#: 305.899.3995 City: Miami Shores State: FL Zip: 33161 Tenant/Lessee Name: Email: jyao@barry.edu I ,� Phone#: k4 V �t CONTRACTOR: Company Name: Kemp Signs & Service Inc. Address: 1740 Hill Ave .t1I 26 Phone#: 561.840.6382 State: FL zip: 33407 Phone#: Certificate of Competency #: j 7� AA(( (r��- �_�' �f p `� Phone#: WC-511 - Il3 Address: i O Iv 1'ed T V\i ZOO _ City:60, Stater Zip: Value of Work for this Permit: $ 2,377.0 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration n New ❑ Repair/Replace n Demolition Description of Work: Installation of (2) illuminated channel letters to read - Dunkin Donuts w/logo cup and Baskin Robbins with logo (BR) City: West Palm Beach Qualifier Name: Stephen Kemp State Certification or Registration #: ES0000229 ^ DESIGNER: Architect/Engineer: er u i s4i- LtAr%1S Specify color of color thru tile: Submittal Fee $ "7-/' M Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ 'c12: -JO r CA sO , TOTAL FEE NOW DUE $ /Nye ) ` (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. i certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit rnust be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning, "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the ab nce of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT Th oregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this tt n / day of A f vtV ___ _____Q' __, 20 I o , by 1(-0 day of Jc 1 1 1 , 20 k , by Lwho ispersonally known to Stephen Kemp Signature me ee or who has produced identification and who did take an oath, NOTARY PUBLIC: Sig Print: eaj;kr Notary Public State of Florida �ci4 Jeffry J Yao , My Commission FF 188481 14S0,>L Expires 11/12/2018 APPROVED BY (RevisedO2/24/2014) 7Akiti ,AO ? CONTRACTOR , who is personally known to as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign:: Print: Seal: Plans Examiner Structural Review 41 'e' ommission # GG 017851 ,_ ti ,,o;$ My Comm. Expires Aug 2, 2020 Bonded through National Notary Assn. id Zoning Clerk 61,,,„Q, STATE OF FLORIDA f DEPARTOEN T OF BUSINESS imv} ? PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD (850) 487-1395 2601 BLAIR STONE ROAD TALLAHASSEE FL 32399-0783 KEMP, STEPHEN MICHAEL KEMP SIGNS & SERVICE INC. 1740 HILL AVE WEST PALM BEACH FL 33407 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTM:EIVT Of BUSINESS AND PROFESSIONAL'REGULATION ES0000229 ISSUED ;:- 08/03/2016 • ti3 1., .. •vi;�s CERT. SPECIAL T .ELECTRIC_AL.0 ONTR KEMP, STEPHEN.MICHAEL'! KEMP SIGNS &r SERVICE'INC. CERTIFIED AS: SIGN ELECTRICAL SPECIALIST IS-GEWT F-IED- under the provisions of Ch.489 FS. Expiration date : AUG 31, 2018 DETACH HERE L1608030002195 KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD LICENSE NUMBER The SPECIALTY ELECTRICAL CONTRACTOR Named below IS CERTIFIED Under.the: provisions of.Chapter 489 FS. Expiration date: AUG 31.,'2018 AS_A SIGN ELECTRICAL SPECIALIST ,KEMP, STEPHEN MICHAEL, " -KEMP SIGNS & SERVICE,IN6'T 1740 HILL-AVE WEST PALM BEACH _.FL 33407 �. • ISSUED: 08/03/2016 DISPLAY AS REQUIRED BY LAW SEQ # L1608030002195 ANNE M. GANNON OONSTITUTIONAL TAX COLLECTOR Serving. Palm Beach County Serving you. P.O. Box 3353, West Palm Beach, FL 33402-3353 **LOCATED AT** www.pbctax.com Tel: (561) 355-2264 • 1740 HILL AVE MANGONIA PARK, FL 33407 TYPE OF BUSINESS OWNER , ' CERTIFICATION # RECEIPT #/DATE PAID AMT PAID BILL # 23-0107 CW ELECTRICAL SPECIALTY KEMP STEPHEN MICHAEL ES0000229 B17.485205 - 07/26/17 $264.60 B40173282 is document is valid only when receipted by the Tax Collector's Office. B1 - 320 KEMP SIGNS & SERVICE INC KEMP SIGNS & SERVICE INC 1740 HILL AVE WEST PALM BEACH, FL 33407 IIIl1111 L J 1111111111111 4. Nat STATE OF FLORIDA PALM BEACH COUNTY 2017/2018 LOCAL BUSINESS TAX RECEIPT LBTR Number: 2015084480 EXPIRES: SEPTEMBER 30, 2018 This receipt grants the privilege of engaging in or managing any business profession or occupation within its jurisdiction and MUST be conspicuously displayed at the place of business and in such a manner as to be open to the view of the public. A N N EM__ M. GANNON CONSTITUTIONAL TAX COLLECTOR Serving Palm Beach County Serving you. P.O. Box 3353, West Palm Beach, FL 33402-3353 **LOCATED AT** www.pbctax.com Tel: (561) 355-2264 1740-HILL AVE MANGONIA PARK, FL 33407 TYPE OF BUSINESS OWNER CERTIFICATION # RECEIPT #/DATE PAID AMT PAID BILL # 23-0170 ELECTRICAL SPECIALTY CONTRACTOR KEMP STEPHEN MICHAEL ES0000229 B17.485204 - 07/26/17 $59.50 B40173283 This document is valid only when receipted by the Tax Collector's Office. KEMP SIGNS & SERVICE INC KEMP SIGNS & SERVICE INC 1740 HILL AVE WEST PALM BEACH, FL 33407 IIIIIIIII1111111111111111 - � a5,, .y.,.. . + , rc �,. j'9a rw*'-e " , eN *sue e. /i' 1 I;' [i1 �' ��;sc.c.-4.1 E 1 STATE OF FLORIDA PALM BEACH COUNTY B3 - 319 2017/2018 LOCAL BUSINESS TAX RECEIPT LBTR Number: 2015084479 EXPIRES: SEPTEMBER 30, 2018 1 ri.Hi` rya .1',td�a s` y rt'',r' P'•r�IkirNF' F .( } t+ 4..,lry}.. f'•,. ay'•'.. ? -.i 9 yi-3 a k. '�" 1 /' E'i Y'.'�' }1 {` ,' ' r a yt. Y P'J yY R S{'�. a 't' dt e: A r14. k 1 • yr.. 1,'r^ .'..k if w F.. This receipt grants the privilege of engaging in or managing any business profession or occupation within its jurisdiction and MUST be conspicuously displayed at the place of business and in such a manner as to be open to the view of the public. .I .- `, fie, , t f e Ce, A i1 ' A fir` F ,ref p .ct • • c; t{ }e , f • • 1 r fy .r •y '7:1. t j 7 ,. KEMPS-1 OP ID: SH .a►oRo CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) 04/17/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Brown & Brown of Florida, Inc Suite 400 1401 Forum Way West Palm Beach, FL 33401 Michael Vega, CRIS CONTACT NAME: Nicholas DiBattisto INC. o, Ext): -686-2266 FAX No): 561-686-2313 E-MAIL ADDRESS: INSURER(S) AFFORDING COVERAGE NAIC # INSURER A: National Trust Insurance Co 20141 INSURED Kemp Signs & Service, Inc. and Kemp Signs Inc Attn: Stephen Kemp 1740 Hill Avenue West Palm Beach, FL 33407 INSURER B: FCCI Insurance Company INSURER C: FFVA Mutual Insurance Co 10385 INSURER D : Federal Insurance Company INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSD SUBR WVD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY GL0016973 07/16/2017 07/16/2018 EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE X OCCUR DAMAGE TO REN I PREMISES (Ea occurrence) $ 100,000 XCU MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GEN'L AGGREGATE X LIMIT APPLIES JE PER: GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OPAGG $ 2,000,000 Emp Ben. $ 1,000,000 B AUTOMOBILE X - X LIABILITY ANY AUTO ALL OWNED X SCHEDULED CA10000393002 07/16/2017 07/16/2018 COMBINED SINGLE LIMIT (Ea accident) $ 1,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ PIP $ 10,000 A X UMBRELLA LIAB EXCESS LIAB X O OCCUR CLAIMS -MADE UMB00193723 07/16/2017 07/16/2018 EACH OCCURRENCE $ 1,000,000 AGGREGATE $ 1,000,000 DED X RETENTION$ 10,000 $ C WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below / N N / A WC84000306112017A 07/16/2017 07/16/2018 X PER STATUTE OTH- ER E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYEE $ 1,000,000 E.L. DISEASE - POLICY LIMIT $ 1,000,000 D Equipment Floater 45467894 07/16/2017 07/16/2018 Leased & 100,000 Rented DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) Sign Manufacturing & Installation CERTIFICATE HOLDER CANCELLATION MIAMI32 Miami Shores Village Building Dept 10050 Ne 2nd Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2014/01) © 1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD BUILDING PERMIT APPLICATION ❑BUILDING ❑® ELECTRIC El PLUMBING ❑ MECHANICAL JOB ADDRESS: Barry University - 11 I`iliami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑ ROOFING Master Permit No Sub Permit No ❑ REVISION ❑ EXTENSI ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCEL CONTRACTOR 300 NE 2nd Avenue - Garner - Dunkin Donuts (e1 T7 FBC 20 — SG N 13 - P1/4-16 1E1c18-10Lkt ON ❑RENEWAL LATION ❑ SHOP DRAWINGS City: Miami Shores Folio/Parcel#:11-2136-000-0050 Occupancy Type: Load: County: Miami Dade Zip: Is the Building Historically Designated: Yes Construction Type: Flood Zone: OWNER: Name (Fee Simple Titleholder): Barry University Address: 11300 NE 2nd Avenue NO X BFE: FFE: Phone#: 305.899.3995 City: Miami Shores State: FL Tenant/Lessee Name: Phone#: Email: jyao@barry.edu Zip: 33161 CONTRACTOR: Company Name: Kemp Signs & Service Inc. Address: 1740 Hill Ave Phone#: 561.840.6382 City: West Palm Beach State: FL Zip: 33407 Qualifier Name: Stephen Kemp Phone#: State Certification or Registration #: ES0000229 Certificate of Competency #: DESIGNER: Architect/Engineer:__����(4►arn �l) 19 Phone#: 8--3-1 I -31 \3 Address: l2-O 0 ..e #ZI City: C•-CATAAState Zip: 2 � - � �� , �c p 3 Value of Work for this Permit: $ ^r Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑� New ❑ Repair/Replace ❑ Demolition Description of Work: Final electrical for (2) illuminated channel letters to read - Dunkin Donuts w/logo cup and Baskin Robbins with logo (BR) Specify color of color thru tile: Submittal Fee $ S• a) Permit Fee $ l 60/v 6 CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ g S j TOTAL FEE NOW DUE $ ,08 • (Revised02/24/2014) ti Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien low brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspectionwhich occurs seven (7) days afterthe building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be ,J prged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this day of A 1'O w ._..... _........_.__ _ _. 20 1 4 , by SU,�N 1L 6N1 NL wh me or who has produced identification and who did take an oath. NOTARY PIJ C: as Sign: Pri S Notary Public State of Florida Jeffry J Yao If My Commission FF 168481 aow Expires 11/12/2018 APPROVED BY (Revised02/24/2014) * Signature The foregoing instrumen t lS day of Stephen Kemp' ONTRACTOR was acknowledged befor”e this 20 a , by , who is personally known to 'me or who has produced as identification and who did take an oath. NOTARY Sign: PUt3 0 ne.,A>k��� !_ Print: r u !i State of Florida l�ll1'l�h��i���' = t � Seal:=;r,��4�o;= My Comm. Expires Aug 2, 2020 OP�"�� 9onded through National Notary Assn. ***t*****************************tart Plans Examiner Structural Review ******************* Zoning Clerk aalIIuftr • • • • et7L• (7R & MAALR�!L,NOTE�S '. •• • • • • • • •• •• • • • NMI WITH $24'X24• CAE TO BE t.or SABIN, COf P G PAINTED TO MATCFI BAND COLOR BELOW OAPWOOOWS E?()ST1HG BUILDING aerono PT• PI-011 • • • • • LOGD46661rERS: • • • tog°. letter faces to be pan formed acrylic; Vinyl to be applied 2nd surface leaving a white ktoy1Rr, Ddtder around all ier ffs. • • • • • • /jv ecicl•IS to be: • • • • • • • DD Orange- 3M #36 -3123 DDMag enta- 3M #3630.1379 • • �D�k�lbwn (on cupltly&-tM #3630$, • • • • Not and letter ret&rru it,. to match BInJryrtn f4pore 2116-10 Nightshade semi -gloss finish dzetwssete 5• deep • • • • e • Weepholes require, for eachilinclividual letter and icon. Letter mumination to eNitlS white LEDs. Baskin Robbins BR Pink-3M #3630-1091 BR Blue-3M #3630-8508 i ItaamPAGT ue +• �iL.s 'Area (sq 9). Square Footage identified is calculated by boxing the entire letter set (wf logo) including the dead space. CHANNEL LETTER ELECTRICAL NOTES Primary wire size - #12 THWN Disconnect switch - at base of sign, 20 amp single pole, Astronomical time -clock at panel room with 10hr battery back-up Maximum load -16 amps 120 volts per circuit maximum circuit size 20 amps per NEC 600-6A Power supply: 120v-277 Multi Volt 60W 12v DC Illumination: Blue -View Optic LED .05 Amp Per Module Conduit - minimum 1 /7' Total sign load - 12 amps 120 volts Total sign circuits - 1 All components shall be U.L. approved Ballasts shall have independent U.L. approval (fused where required) All installations shall be in compliance with N.E.C. and state, county, or local codes All signs shalt be bonded to building equipment bonding conductor per N.E.C. 250 "IF ,[S,(GNS ANp SERVICE, ir.lr 1 (Enh 1 Sid •411S% KM SIX 11135 7755' «=3 eitipAOG UDR ROO [pros 1 .t . laid ANCHOR SCHEDULE • WThiMPACT n om 14.11. "ALL FASTENERS SHALL BE SPACED EVENLY•' �t4 WALL MATERIAL l ANCHOR TYPE SPACING CONCRETE (3ksi) or HOLLOW MASONRY 1/4" THREADED RODS WITH MIN 2" EMBED IN ADHESIVE MIN (6) EA LETTERSET 1/4" TAPCONS (OR EQUIV) WITH 1.75" EMBED MIN (6) EA LETTERSET 1/4" EXPANSION ANCHORS WITH 2.5" EMBED MIN (6) EA LETTERSET 1/2" PLYWOOD (NO ACCESS BEHIND) 1/4" TOGGLE BOLTS MIN (6) EA LETTERSET 1/4" WOOD SCREWS OR TAPCONS, FULL EMBED MIN (6) EA LETTERSET METAL STUDS OR METAL PANELS #14 METAL SCREWS TO MIN 18ga STEEL OR 0.090" ALUM MIN (6) EA LETTERSET HOLLOW WALL (BLOCKING BEHIND) 1/4" THRUBOLTS OR LAGS TO SOLID BLOCKING BEHIND MIN 6) EA LETTERSET ANCHOR SCHEDULE APPLIES TO "DUNKIN DONUTS" LETTERSETS. AT "CUP" LOGO, 36" LTRS, & 12" LTRS USE ANY ANCHOR OPTION SHOWN: • MIN (6) AT LOGO & EA 36" LETTER • MIN (3) PER 12" LETTER 1740 HILL AVENUE WEST PALM BEACH, FL. 33407 561-840-6382 (FAX) 561-840-6385 CUSTOMER: DUNKIN' DONUTS BARRY UNIVERSITY -GARNER HALL 11300 NW 2nd AVE.. MIAMI SHORES, FL 33161 63" This item has been electroni- cally signed and sealed by Christian Langley. PE using a Dgyal Signature. Printed copies this document are not considered signed and sealed and the signature must be verified on any ekctmnk copies. .9Jip-M.Sa w.0:76rwra ±rose; r:ao:rsr 22.75'sqft 52.5" 4 43.375" LED Cloud Sign Side View Formed "Cap Over" Face 1 ea 2nd Surface Vinyl (Per color Call -outs) .063 Alum. Back, Pre -Painted White White LED's Coffee Cup Only to be Embossed (All Other ► Faces To Be Flat) .040 Returns ptd. BM2116-10 Nightshade Semi -gloss Finish SALES PERSON: DRAWN BY: PAM REEVES. SCALE: AS NOTED DATE DRAWN: 02.19.18 Digitally signed by Christian Langley Date: 2018.02.22 15:18:23-05'00' 36" 98.5 12" 12" 60.87 Sqft 1 D 38.125" RECT D 4 PR 1 9 2018 BY. Disconnect Swi 5', 8 y T �•`�Q� .. E N SF ® No.67382 7. '1:41 STATE OF OA,• A�OR10•••C9 si©N A1. 54.5" TS� f L i COPYRIGHT 2016 BY KEMP SIGN & SERVICE. ALL RIGHTS RESERVED al REVISION: #100.00.00 #1 00.00.00 #1 00.00.00 #1 00.00.00 Fastener Locations (2) tC7/ 24" OC 18" 1 • ta,sy dj1S Plastic Faces to be Acrylite FF- Thermoforming plastic C (9- (qqa Miami Shores Villige APPROVED BY DATE lr� 7 IPA. ZONING DEPT r t r,r" r-.cTr,T qt`A . r��t�l••iM,■ rANNIEL•%rja -tea -� t;l:,11 C TO COMI'l IANCE WITH ALL FE )ERAL ,; I A 11 A' .I) (.11UNI IY RUl FS AND HEGULATIONS CUSTOMER APPROVAL: ,FGr j` 0 Da.I•ft IV CO ry C 7X cWaa 'OQ _moo O V U 0 ON rn rn rn•— = J m LL LL(r� z N m General• D re with the is fthe Fla Bld Cod 6thEd(2017) for use within & outside the High Velocity Hurricane Zone (HVHZ) This engineering certifies only the structural integrity of those systems components and/or other construction explicitly spedhedherein. •Eleddcalnotes, details, &spedhcntionsare pmyidedbyand are the sole responsibility ofthe electrical contractor. Noekddcalreview has been performed and nocertification ofsuch isintended. •Stmduraldesign meets requirements ofAG318-14,AISC360-10,ADM1-15,&NDS15, Notes: esignismacco accordance requirements o g e as applicable. • Steel components shall be coated, painted, or otherwise protected against corrosion per IBC Sec 7203.2/2211.6. • Alum components in contact with steel or embedded in concrete shall be painted or protected as prescribed in ADMI-15(la), or plastic/neoprene spacers provided. •AII exposed fasteners shall be S.S. or have a protective coating for COM)Slerl protection. • All welding shall comply with AWS requirements. • Steel welds: E70xx electrodes. • Aluminum welds: 4043 filler alloy. • Alum extrusions: 6063-T6 or stronger, U.N.O. • • •• • • • • • • •• • •• • • • • • • • • • • • • • • • • • • • •••• •• •• • • • • • •• • • • • •••• • • • • • •••• • • • • •••• • • • •••• • •• • • • • •••• • • • • •••• NTS [SIGNS —AND —SERVICE/ 4 SITE PLAN KEY SITE PLAN NOTE potTIN`Q • .GRASS.AND SHRUBS ITO • `REMAIN AND RRVSED• EW GREA RAP .XISTING COURTYARD • NEW LANDSCAPE (SHURBS) AND GRASS • EXISTING TREE TO REMAIN AND REUSED • PROVIDE 6.-8" BARRIERS 14110UND TREES-LESS-THAN-18 INCH DIAMETER AND SHOW 1412" BARRIERS AROUND TREES 18INCHES IN DIAMETER OR �.� GREATER • NO TREE REMOVAL IS BEING PROPOSED NORTH P.A1641 EX STING EX I tKIVK KAMP IEB EXISTING BUILDING EXISTING BUILDING 0'-2 1 C/R DRESSING EXIST. VESTI i....i....... tX PROPOSED DUNKIN' DONUTS ELEV: 14.17' • REDBVE OPgD.. COURT ARD (PER E . • AREA)SEE SHEET 1 FOR ,•' GRADING AND , ' DRAIN&UE . EXISTING BUILDING 37'-10148 • • 56' 9 l J/ 12 • STAIR NO .EXISTIN �`. M fly EXITING 15/9L4'fq REMAIN ANDI 11 '— REUSED •— REUSED . . - - PROVIDE 6.-8" BARR1€R5-AROUND TREES LESS -THAN 18 INCHES IN` DIAMEgkeNQ St 10'-12" BARRIERS AROUND THE S IBINCH ES INDIAMETER OR GR ER ' ` • • v EXISTING BUILDING ELECTRICAL ROOM EXISTING CORRIDOR EXISTING GRASS?/$t U.R TO REMAIN.AND REUSED 34'-to 3n1/ RELOCD EXISTING OUTD R SEATING 345 SQ RELOCATED EXISTING ARCADE • EXISTING PALMS TO REMAIN AND ` REUSED T'eOVIDI6L8 BARRIERSAROUN➢ TREES LESS THAN 18 INCHE$ IN DIAMETER AND * SHOW 1➢' 12" BARRIERS AROUND ;REES 1SINCHES IN DIAMETER OR EXISTING CATCH BASIN EXISTING BUILDING 0 Lig ' . CEP4s�' a• development inc as 2 F. )f , EXISTING ARCADE Pc1IS •• VENTURA • .� �michael o vent .rp ' n ' ;1137t: 'ttit� et IV " r;; daviol1,17 da 3 ,F.5. � % �, M M phone : (954) 423-1362 c ventura-crchitecture.com a Cl. A fo ot A A 0 0 0 3 1 2 3 = o `ot .c LL G/ U (.4 m rn.— = J OS LL 2 C.R. 11 O V1 CO AR001 61 52 ci�o000 z o — au N EXIS I INI, COURTYARD EXISTING • - GRASS-4SHDRB' •-(0 R€ICA/11A gelt, -REUSED 1740 HILL AVENUE WEST PALM BEACH, FL. 33407 561-840-6382 (FAX) 561-840-6385 CUSTOMER: DUNKIN' DONUTS BARRY UNIVERSITY -GARNER HALL 11300 NW 2nd AVE. MIAMI SHORES, FL 33161 SALES PERSON: DRAWN BY: PAM REEVES. SCALE: AS NOTED COPYRIGHT 2016 BY KEMP SIGN & SERVICE. ALL RIGHTS RESERVED DATE DRAWN: 02.19.18 REVISION: #1 00.00.00 #1 00.00.00 #1 00.00.00 #1 00.00.00 CUSTOMER APPROVAL: DATE: KI El GARNER HALL BLDG revisions: 02-09-IS TREE REVIEW COMMENT Drawn by: Pedro Rincon date: 11-21-2017 sP- GeneralDesign is in accordanCe with the requirements of the Fla Bldg Code 6th Ed (20'17) for use within & outside the High Velocity Huriicane Zone (HVHZ). • This engineering certifies only the structural integrity of those systems, components, and/or other construction explicitly specified herein. • Electrical notes, details, & specifications are provided by and are the sole responsibility of the electrical contractor. No electrical review has been performed and no certification of such is intended. • Structural design meets requitement of AC1318-14, A'S( 360-10, AD#1-15, & ND5-15, Notes: as applicable. • Steel canponent1 shah be coated, painted, or otherwise protected against corrosion per FBC Sec 2203.2/2222.6. • Alum components in contact with steel or embedded in concrete shall be painted or protected as prescribed in ADM1-15(1a), or plastic/neoprene spacers provided. • All exposed fasteners shall be SS. or have a protective coating for corrosion protection. • A0 welding shall comply with AWS requirements. • Steel welds: E70xx electrodes. • Aluminum welds: 4043 filler alloy. - Alum extrusions: 6063-T6 or stronger, U.N.O. EasySeals easyseals.com • • • • . • • • • • •., • •• Gy�rIERALTFOT • .' 1. DESIGN CALCULATIONS FOR DUNKIN DONUTS WALL -MOUNTED SIGNS 11300 NW 2nd Ave — Miami • .. • • • Design iS in accordgrfce'with the Florida Building Code 6th Edition (2017) for use wIhin and outsitre the High Velocity Hurricane Zone (HVHZ). •• • • • •'c• • Wind loads have beerreeic•ulated per the requirements of ASCE 7-10 as •••••• • • • shownehereiti. • • • • • • • a• • These eggipgering «ICulatjons pertain only to the structural integrity of • • those.sys ems, componeots, and/or other construction explicitly specifiedkierein an& or ineccompanying engineering drawings. The existing most structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. This item has been electroni- cally signed and sealed by Christian Langley, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Digital Signature Sena' Number: M 9932 DI 117997g 6Dg76F 60 F6 Index: Digitally signed by Christian Langley Date: 2018.02.22 15:18:06 -05'00' Pg 1 Cover Pg 2 Wind Loads Pg 3 Anchor Design .orl Eng; eerr ‘h t�rA: • jds eal valid �;q.,-t,reaaVL '��4togi" 3 i 4' •tie-. ., le,TATE�+' ,Feb : ChY`rst1ip,51;"�eyIS %,RE`# 67382 Easy Sealsrrrr,aa + Auth # 31124 1200 N Federal Hwy, #200 Boca Raton, FL 33432 Easy Sea Is Page 1 EasySeals easYseals corn ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs CALCULATIONS FOR WALL -MOUNTED SIGNS V = 175 mph Basic wind speed ASD Load Combo Coeff: 0.6 Exposure C Calculations a = 9.5 zg = 900' Gcpi = 0 • • .• • .• 3-sec gust speed power law exponent Nominal ht. of atmos. boundary layer Internal pressure coeff 175 mph - Exp "C" WALL -MOUNTED SIGNS SIGN HEIGHT ASD WIND CENTER (Zone 4) PRESSURES CORNER (Zone 5) 15 ft 37.3 psf 47.5 psf ..4% 39.7 psf 50.5 psf 25 f1 410 ps* 52.9 psf •:1biti ft 43.2 psi, 4' T 8 pSf •55 55.0 psf 56.8 psf •.141* 459eV 58.4psf 45 ft. 47.1 psf 59.9 psf • 50 ft• 484qpsf 61.2 psf S5 ft Wit psf 62.5 psf •,§4 ft 59.0 p;f 63.6 psf •.79#� 4�2.lpsf: 84.5 psf 'EC ft 43.5 psf 86.9 psf 90 ft 44.5 psf 89.1 psf 100 ft 45.5 psf 91.1 psf 110 ft 46.5 psf 92.9 psf 120 ft 47.3 psf 94.7 psf 130 ft 48.1 psf 96.3 psf 140 ft 48.9 psf 97.8 psf 150 ft 49.6 psf 99.2 psf 175 ft 51.2 psf 102.5 psf 200 ft 52.7 psf 105.4 psf 250 ft 55.2 psf 110.5 psf 0.85 0.90 0.95 0.98 1.01 1.04 1.07 1.09 1.12 1.14 1.17 1.21 1.24 1.27 1.29 1.32 1.34 1.36 1.38 1.42 1.46 1.53 Kd = 0.85 Directionality factor Kzt = 1.0 Topographic factor A = 10 sq ft Tributary area a a qz Vr 0 ,,, 56.6 -1.10 -1.40 60.1 -1.10 -1.40 63.0 -1.10 -1.40 65.5 -1.10 -1.40 67.6 -1.10 -1.40 69.5 -1.10 1.40 71.3 -1.10 -1.40 72.9 -1.10 -1.40 74.4 -1.10 -1.40 75.7 -1.10 -1.40 78.2 -0.90 -1.80 80.5 -0.90 -1.80 82.5 -0.90 -1.80 84.3 -0,90 -1.80 86.1 -0.90 -1.80 87.6 -0.90 -1.80 89.1 -0.90 -1.80 90.5 -0.90 -1.80 91.9 -0.90 -1.80 94.9 -0.90 -1.80 97.6 -0.90 -1.80 102.3 -0.90 -1.80 Page 2 Easy Seals Wall Sign Anchor Design Structure Dimensions & Loading CALCULATIONS FOR WALL -MOUNTED SIGNS Design wind pressure: P = 55.0 psf Sign type: Sign size: Cabinet A = 11.1 sqft (entire cabinet) Wall material: Masonry (ASTM C90, 1,500 psi min) Anchor type/size: 1/4" Tapcon Ref: ITW Tapcon, NOA 07-1126.10 Min Embedment: 1.25" Min edge dist: 2.5" Min Spacing: 3" Anchor tensile capacity: Tcap = 195.0 Ib (per anchor) Check Anchors for Pullout • • •• . •. • •T.otal Reaction: Rt = 612 Ib ...= P*A (entire cabinet) No. OT nchor.req1I: n = 3.1 total anchors = Rt/cap • • • • Total anchors required: 4 total anchors balanced over cabinet •••• •• •• • •• • • • ••• • • • Olf,typical anchor option at critical logo size shown. Ref anchor schedule for other anchor options. • • • • • • • • • Min (6) at logo & 36" letters, min (3) per other letter. • • • • • • • • • •••• •• •• • • •••• • • • Page 3