Loading...
EL-18-1837Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Parcel Number Issue Dal Permit NO. EL-7-18-1837 Permit Type: Electrical -Residential Work Classification: Low Voltage Permit Status: APPROVED 712712018 Expiration: 01/23/2019 Applicant 29 NE 102 Street Miami Shores, FL 33138- 1132060131650 Block: Lot: CARLOS ANDRADE Owner Information Address Phone Cell CHRISTIAN ULVERT 29 N 102 Street MIAMI SHORES FL 33138- (305)336-3631 29 N 102 Street MIAMI SHORES FL 33138- Contractor(s) HOME OWNER Phone Cell Phone Valuation: Total Sq Feet: $ 1,000.00 0 Type of Work: ADD ELECTRICAL OUTLETS AND OVERHEAD Additional Info: ADD ELECTRICAL OUTLETS AND OVERHEAD Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Notary Fee Permit Fee - Additions/Alterations Scanning Fee Technology Fee Amount $0.60 $2.25 $2.00 $0.20 $5.00 $150.00 $9.00 $0.80 Total: $169.85 Pay Date Pay Type Amt Paid Amt Due Invoice # EL-7-18-68159 07/09/2018 Cash $ 50.00 $ 119.85 07/27/2018 Credit Card $ 119.85 $ 0.00 Available Inspections: Inspection Type: Review Electrical Review Electrical Review Electrical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAV_ : I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and g. Futhermore, I authorize the above -named contractor to do the work stated. onzed Sjghature: Owner / Applicant / Contractor / Agent July 27, 2018 Date Building Department Copy July 27, 2018 1 BUILDING PERMIT APPLICATION ❑ BUILDING %ELECTRIC El PLUMBING ❑ MECHANICAL JOB ADDRESS: Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED JUL 16 2018 0+\ FBC 201'4 Master Permit No.(iL i8 1$3 Sub Permit No. ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL Ei PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS 2aq--ne G . City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Address: I3f5 NO Occupancy Type: Load: Constructiont/}'Type: (Flood Zone: �,/y1 — BFE: FFE: OWNER: Name (Fee Simple Titleholder): V" I t O,I L1t_, vC/ 1 Phone#: b) 3.36)-3(03/ City: l v2',1' �'ft N/�State: \ lr Zip: � 2g toe Tenant/Lessee Name: Phone#: Email: Glr)voi`VWv Vlpy-TL (4,ToLil,(JYY-N CONTRACTOR: Company Name: Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency#: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Type of Work: ❑ Addition Description of Work: 1 /Q Square/Linear Footage of Work: ri Alteration n New Repair/Replace OfeArad CrALL mac, (An* ❑ Demolition Specify color of color thru tile: _ Submittal Fee $ Permit Fee $ 45:03 CCF $ CO/CC $ Scanning Fee $ Radon Fee $ a - DBPR $ • Notary $ 1 t Technology Fee $ Training/Education Fee $ Double Fee$ Structural Reviews $ Bond $ TOTAL FEE NOW DUE$ / (9 • as i (Revised02/24/2014) 1 Bonding; Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address r. " .) City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with a'n estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature 0 NER or AGEN CONTRACTOR The foregoing instrument wasacknowledgedbefore me this The foregoing instrument was acknowledged before me this Ala day of TU, , 20 by day of , 20 , by Ghr tS�G 1 UN Ve4ho is persona known to , who is personally known to me or who has produced - as me or who has produced as identification and who did take an oath. identification and who did take an oath. Seal: APPROVED BY NOTARY PUBLIC: Sign: Print: Seal: 746 Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 1f�OWNER BUIL DER DISCLOSURE STATEMENT NAME:0../V\S-\\AVA-► DATE: ADDRESS: 'ice 102-. , NIY\IOVI/1/� ‘ Oilers - a3 i3B Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year'after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial 2. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. I understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. I understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the ,. construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial�__2. 5. I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial •C 6. I understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial�� 8. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial__ 9. I agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial 10. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.html Initial 11. I am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: C9 t NZ r \NMt 6 , 33133 Initial 1 12. I agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that have provided on this disclosure. Initial CJ— Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's worker's compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this day of 20 I By @.)[' N� `IV 6I , U 1V�Uf who was personally known to me or who has Produced ther 40" 0 NER as identification. NOTARY 7/9/2018 Property Search Application - Miami -Dade County ti Summary Report Property Information Folio: 11-3206-013-1650 Property Address: 29 NE 102 ST Miami Shores, FL 33138-2322 Owner CHRISTIAN ULVERT CARLOS ANDRADE Mailing Address 29 NE 102 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2 / 0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,744 Sq.Ft Lot Size 11,400 Sq.Ft Year Built 1948 Assessment Information Year 2018 2017 2016 Land Value $284,848 $284,848 $284,848 Building Value $177,502 $177,502 $177,502 XF Value $33,049 $33,423 $33,796 Market Value $495,399 $495,773 $496,146 Assessed Value $495,399 $495,773 $496,146 Benefits Information Benefit Type 2018 2017 2016 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 15 & LOT 16 BLK 12 LOT SIZE 100.000 X 114 OR 20132-0809 12 2001 1 COC 21752-3084 10 2003 1 Generated On : 7/9/2018 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $445,399 $445,773 $446,146 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $470,399 $470,773 $471,146 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $445,399 $445,773 $446,146 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $445,399'' $445,773 $446,146 Sales Information Previous Sale Price OR Book -Page Qualification Description 07/19/2017 $585,000 30633-1673 Qual by exam of deed 02/24/2014 $510,000 29063-3603 Qual by exam of deed 10/01/2003 $333,000 21752-3084 Sales which are qualified 12/01/2001 $275,000 20132-0809 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: BUILDING PERMIT APPLICATION ❑BUILDING g ELECTRIC m'PLUMBING ❑ MECHANICAL Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED � 1U0 120p� C 20 n- Master Permit No. �t - t ❑ ROOFING ❑ REVISION ❑PUBLIC WORKS ❑ CHANGE OF CONTRACTOR JOB ADDRESS: O[ q n \--Cy+ o6unty:4- Sub Permit No. City: Miami Shores ,ff C "„ J1: Miami Dade Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: OWNER: Name (Fee Simple Titleholder): Construction Type: Flood Zone: 0)1(161--Avl VAN Address: 2-r1• lC 10 Z S"\-- ' City:( OUI'MJ State: .� ❑ EXTENSION ❑ RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS zip: 3138 NO ✓ BFE: FFE: Phone#: C 0.. ) 334' 3631 Zip: 33 ( S Tenant/Lessee Name:cPhone#: Email: lam► \Vio\W\ � . k.A\V€Y4 e CONTRACTOR: Company Name: Address: tywAA. \. o Q_ OVJ City: :_Zip: Qualifier Name: ! ti=`r ' bone#: i •. State Certification or Registration #: Certificate of Competency #: Phone#: f33, t _ DESIGNER: Architect/Engineer: Address: City: Value of Work for this Permit: $ It o00 Type of Work: ❑ Addition ❑ Alteration . Phone#: State: Zip: Square/Linear Footage of Work: ❑ New ❑`Repair/Replace ❑ Demolition r Description of Work: QoEvk S gam,.; ra-� ; :w.r� Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) s• I Bonding Company s Name (if applicable) ^` x Bonding Company s Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City ' + :State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ,. ; "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and, construction lien law brochure -will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspecti6n fee will be charged. r Signatur X Ct„ Signature ~� OWNER or AGENT '' - CONTRACTOR The foregoing instrument was acknowledged before me this - The foregoing instrument was acknowledged before me this r •�— day of 3.0 \ , 20 I'?) , by day of , 20 by C1 11 t 1 G h 0 I J hb is personally known to , who is personally known to me or who has produced r 1 1 i (Q.., 1�./ as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLI _ NOTARY PUBLIC: Si Print: Seal: Sign: Print: Seal: APPROVED BY Plans Examiner Zoning (Revised02/24/20141 Structural Review Clerk • • :1.1 • •• • •• • • • • • • • • • • • • •• • • • • RECEIVE JUL 16 2018 D q441 • • ••• • • • ••• •S. •• • • •• • •• •. • • • . • •• •• • •• • • • • • • •• •.• • • •• • • •• •• • •• •• • • • • • • • •• •• • • • • • 010D41 • • . • • • • • • •• • •• F. • • • .. .«---_ N • • . - • .• • • • • . • • • • • •• • • • •• • •• a U w J Lit w c- -'t—_E. �a" S �S te. 6ywety 009f C A roast P U a) w 29 NE 102 STREET. co 0 N J LOAD CALCULATION CIRCUIT #1: OUTLETS 6 Outlets 15 AMP e/a Total charge: 90 AMP For these will be use a Breaker protection 100 AMP CIRCUIT #2: LAMPS 3 Ceiling Lamps 53 W e/a 4 Ceiling Lamps 21 W e/a Total charge: 243 W / 2.025 AMP For these will be use a Breaker protection 20 AMP CIRCUIT #3: GREE LIVO I Inverter Mini Split 136.000 BTU Normal Operational Voltage 208/230 V, I Phase, 60 HZ Voltage range 187 — 253 V Total charge: 40 AMP For these will be use a Breaker protection 60 AMP 29 NE 102 St. Miami Shores, Fl. 33181 • •.... • . . • .. . ... . . .. • .. . • • • .... • • .... . .. . . • . . . .... . • .. . • . • . • • . . . . .. . .. . . . . • Electric panel € Outlet ® Lamp j Switch €1 Air conditioner •... . . • •••• • . •• • • • •. .. • • • .• .... . . . . • • .... . I. . . • . . • . . .. •. . •. I • • • • . • • . • • • • • •. . .. . .. • . . .• . PANEL SCHEDULE 1 Outlet 120v 2 Center lights 3 Entry lights 4 AC 5 AC 6 North side 7 East side 8 Spare .... . . . • .... . . . .. • • .... . . .... . . ..• .. . • . . . • • • . S. .. . . ... . . . .. . • . . . • .. • • . . • .. . • . . .. . . . . • . • • Condensate Drain IU-1 Installed Per Manufacture Specification Existing Garage 21FT X 22FT II Electrical & Refrigerant Lines New Electrical Disconnect for Outdoor Unit < 8" minimum ••. • • OU-1 Installed Per Manufacture Specification Job site: New Mini Split unit in Existing • • • • .. - ••• • Carlos Andrade Garage space • • • 29 NE 102nd Street • • Miami, Florida 33138 .,.• • MECHANICAL ^ 1 APPROVED DATE • • • • • • • • •• •• • • • • • • • • • • I. • • ••. • • • • •• • • • • • •• • • . • � • • • • • • •• • • • • Job Site: Carlos Andrade — 29 NE 102❑d Street Miami, FL 33138 MECHANICAL LEGEND CT) PROPOSED MINI -SPOT INDOOR UNIT REMOTE T MOUNTED 441r A.F. AT MINI SPLIT SYSTEM AIR CONDITIONER SCHEDULE OUTDOOR UNIT NO. MANUF. NO. OUTDOOR BTU'S VOLTAGE HxWxD DIMENSIONS CONNECTION LIQUID CONNECTION SUCTION OU-1 LIVS36HP230V1B0 33,600 208/230 31.2"x39.4"x16.8" %" 5/8" *INDICATES LOW AMBIENT OPERATION OUTDOOR UNIT GREE MINI SPLIT AIR CONDITIONERS 16 SEER MINI SPLIT SYSTEM AIR CONDITIONER SCHEDULE INDOOR UNIT NO. MANUF. NO. OUTDOOR BTU'S VOLTAGE HxWxD DIMENSIONS CONNECTION LIQUID CONNECTION SUCTION IU-1 LIVS36HP230V1BH 33,600 208/230 12.8"x53.2"x10" '''A" 5/8" .... • . • • • . . .... .. •••• . . .. S. . • . • . • . . .. • . • • 0000 . .. . .• MECHANICAL NOTES 1. ALL SPECIFICATIONS AND DRAWINGS tie - ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION) ARE CaVPUMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. 2. ANY CONFLICTS WITHIN TIE SPECIFICA'iIONS OR BETWEEN THE SPECIFICATIONS AND DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. T'I CONTRACTOR SHALL NOT PROCEED WITH ANY WORK UNTIL ALL CONFLICTS ARE RESOLVED AND TIE CLARIFYING INFORMATION IS ISSUED TO THE CONTRACTOR BY THE ARCHITECT. 3. ALL CUTTING, #MILLING AND PATCHING OF WALLS, FLOORS OR STRUCTURAL MMBERS FOR THE INSTALLATION OF THE MECHANICAL AND/OR PLUMBING SYSTEMS SHALL BE PROVIDED BY THE MECHANICAL OR PLUMBING CONTRACTORS. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL 4. ALL PIPING SHALL BE INSTALLED ABOVE CEILING OR IN CONCEALED SPACE UNLESS NOTED OR INDICATED OTHERWISE. COORDINATE WITH THE ARCHITECTURAL DRAWINGS REQUIREMENTS. 5. THESE DRAWINGS ARE SCHEMATIC AND ARE INTENDED TO CONVEY A FUNCTIONAL HVAC SYSTEM AND TO DEPICT RE GENERAL LOCATION OF THE HVAC SYSTEM BENTS. 6. CONTRACTOR SHALL EXAMINE THE CONTRACT DOCUMENTS AND FAMIUARfZE HIMSELF WITH ALL THE. REM/RE/ANTS OF THE PROJECT AND SHALL NOTIFY THE ARCHITECT OF ANY OBSERVED FAULTS AMOR AMBIGUITY IN THE CONTRACT DOCUMENTS SO THAT TIE M . ! tH MAY BE RESOLVED PRIOR TO SUBMISSION OF BIDS. 7. BY SUBMISSION OF BID THE CONTRACTOR SHALL ACKNOWLEDGE ACCEPTANCE OF THE CONTRACT DOCUMENTS AS AN ADEQUATE DEFINITION OF THE SCOPE OF THE WORK, AND EXTRA COST CLAIMS BASED ON INADEQUACY OF DOCUMENTS SHALL NOT BE CONSIDERED. S. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HVAC AND PLUMING WORK WITH THE. WORK OF OTHERTRADES. MINOR DEVIATIONS FROM PLANS MAY BE MADE TO AVOID MINOR CONFLICTS, WHEN MAJOR CONFLICTS ARE APPARENT, THE PROJECT MANAGER SHALL BE ADVISED IMMEDIATELY AND AFFECTED WORK SHALL NOT PROCEED UNTIL THE CONFLICT HAS BEEN RESOLVED. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO PURCHASING AM FABRICATION OF EQUIPMENT (le - DUCTWORK, DIFFUSERS, ETC.) 10. CONTRACTOR SHALL VERIFY ALL VC/JADE AND POWER REQUIREMENTS FOR ALL EQUIPMENT AM COORDINATE WITH THE CONTRACT DRAWINGS PRE TO ISSUANCE OF SHCC DRAWINGS AND PURCHASE OF EQUIPMENT. 11. ALL SYSTEMS SHALL BE CLEAN OF FOREIGN MATERIAL AND ROUGH SPOTS PRIOR TO BEING PLACEQ... IN SERVICE AND BEFORE OPERATIONAL TESTS ARE PERFORMED. • ... .• • 12. ALL REFRIGERANT PIPING SHALL BE CONNECTED TO RESPECTIVE A U AND U. • DIAMEtER • • •• C • . • LENGTH OF RUN SHALL NOT EXCEED PER MANUFACTURER'S SPECIFICATIONS. • 13. INSTALL U.L APPROVED FIRE DAMPERS WHERE NECESSARY AS PER NFPA LOCAL CAE 'Np THE: MANUFACTURERS RECOMMENDATIONS. PROVIDE ACCESS PANELSIDOORS TO FIRE DAMPERS AS* REQUIRED. •••• 14. PROVIDE AIR TURNING DEVICES iN DUCTWORK AT ANY CHANGES IN DIRECTION. . 1S. INSTALLATION OF ALL EQUIPMENT AND THEIR ACCESSORIES SHALL BE PER MANUFAC'flJI FITS • PUBLISHED RECOMMENDATIONS. . . . .. . .. • . . . 16. ALL FLOOR MOULTED EQUIPMENT SHALL BE INSTALLED ON VIBRATION ISOLATORS • • • PART NAMES Indoor unit Part Name 1. Front Panel 2. Aux. Button 3. Air Filter 4. Horizontal Louver 5. Remote Controller 6. X-41 Wired Tether Controller (sold separately) 7. Inter -Connection Wire 8. Drain Hose 9. Refrigerant Lines Outdoor unit Air inlet Air outlet 5 Air inlet II II lull ill 1 I IIIIII 111i Il III mmHg ninon' !III IiIIIIIIiIIIIIIIIIII IIIIIII I I' I IIII IIIIIIIIIIII IIIIII111 II III; 011111111111111111111111111 inn ill.II IIIIII11111111lIlI�i li'!' Air outlet r GREE 5 •• • • • • • • ...• • . . •. • •.• . • • .. • .... . • .... . . •. •• • . . • . • . • . • .. • • • • . • • . • . .... . . • .. . . •. • • . • • • • • • • • INSTALLATION SITE INSTRUCTIONS Indoor Unit Select a site that allows for the following: 1. Ensure the installation complies with the installation minimum dimensions (defined below) and meets the minimum and maximum connecting piping length and maximum change in elevation as defined in the System Requirements section. 2. Air inlet and outlet will be clear of obstructions ensuring proper airflow throughout the room. 3. Condensate can be easily and safely drained. 4. All connections can be easily made to outdoor unit. 5. Indoor unit is out of reach of children. 6. A mounting wall strong enough to withstand four times the full weight and vibration of the unit. 7. Filter can be easily accessed for cleaning. 8. Leave enough free space to allow access for routine maintenance. 9. Install at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where reception is weak. An amplifier may be required for the affected device. 10. Do not install in a laundry room or by a swimming pool due to the corrosive environment. Minimum Indoor clearances Ceiling 8 ••. • • • • • • • • • • . • S. . • • • • • • .• • . • • • • • • ••. • • • .••. • • •. •• • • • • • • • • • • •• • •. .••. • • • •• • • • •• • • • • • • •• • • • INSTALLATION SITE INSTRUCTIONS Outdoor Unit Select a site that allows for the following: 1. Outdoor location meets all minimum installation clearances defined below. 2. Sound from outdoor unit will not annoy neighbors 3. All connections can be easily made to indoor unit. 4. Air inlet and outlet will be clear of obstructions to ensure proper airflow. 5. Wall or roof is strong enough to withstand the full weight and vibration of the outdoor unit (for wall or roof installation only). 6. Outdoor unit is out of reach of children and does not obstruct walkways 7. Outdoor unit is not exposed to direct sunlight excessive dust or strong wind. 8. Condensate water can drain freely during heating 9. Maintenance and repairs can be easily performed on the outdoor unit. 10. Ensure the installation complies with the minimum and maximum connecting piping length and maximum change in elevation as defined in the System Requirements section. Minimum Outdoor Clearances A B C D E 20 (500) 12 (305) 20 (500) 78 (1980) 12 (305) Air inlet r GREE 9 .... • • • .... • . . .. • ... . • . .. • .... • . .... • • .. .. • . . • . • . • . • .. • . . . .... . . . .. . • .• • . • . • • • • . . .. . . . . . . OUTDOOR UNIT INSTALLATION Ground Pad or Wall Hangers Installation 1. Determine proper location for outdoor unit. 1. Follow all instructions provided by manufacturer for installing wall hangers or ground pad. 3. Verify the wall hangers or ground pad can safely support the weight of the outdoor unit. 4. Verify the wall hangers or ground pad is level and meets all outdoor dimensional clearances Outdoor Unit Risers Installation If the outdoor unit requires added elevation above the ground, installing riser legs will provide a sturdy and stable solution. Follow all instructions provided by manufacturer for installing riser legs to outdoor unit. NOTE: Riser legs will also help absorb vibrations and noise while facilitating proper drainage. NOTE: To meet Florida Wind Load criteria, the outdoor unit must be anchored to concrete pad using four 3/8-in diameter Power Wedge Bolt Plus (or equivalent) with 1-in diameter fender washers Anchor bolts must be embedded into 3,000 PSI minimum concrete at a distance of 41 /2 -in from any concrete edge. The concrete thickness must exceed 1.5 times the anchor depth. I Condensate Drain Installation for Outdoor Unit During normal heating and defrost operation, the outdoor unit will generate condensate water The condensate water should be routed to a safe location through the drain hose. 1. Locate and select a drain hole on bottom of outdoor unit. 2. Install the outdoor drain fitting into hole on the bottom of outdoor unit as shown. 3. Connect the drain hose to drain fitting. 4. Route drain hose to safe location for proper drainage of excess condensate water. 5. All non -used drain holes should be plugged. Drain Fitting Installation 14 •••• . • • • ••.• • • • • S. • ••• • • . . .• • • • • •••• • • • • •••• • • • • • •••• • • • • • •• •• •• • • • • • • • • • • • • • • • • • •• • •• • • • • PIPING INSTALLATION Refrigerant Piping Drill Hole in Wall If indoor unit refrigerant piping is going to exit from the rear. 1. It is recommended that the refrigerant pipe flare connectors extend through the wall to the outside. In some situations field -fabricated piping extensions will be required to extend the indoor unit refrigerant flare connections to the outside of the wall. 7. Use mounting bracket diagrams and dimensions to find and mark the proper location for the wall hole. If refrigerant piping is going through the right or left side of front panel: Carefully cut hole in the side of the front panel for piping to enter indoor unit as shown below. Find and mark the proper location for the wall hole. Use table below to determine recommended wall hole size for your unit size. Left Side Cut Piping Hole Right Side Table of Wall Hole Size per Unit Size 9,000 12,000 18,000 24,000 ' 30,000 36,000 �e��fitisiriet'er1 2 1/4 2 1/4 23/4 2 3/4 2 3/4 23/4 55 55 66 66 66 66 3. Cut the wall hole with a 5° to 10° downward slant to the outdoors 4. Insert a wall sleeve into hole to prevent damage to refrigerant pipes, insulation, condensate drain hose and wiring. 5. Proper weather proofing of the wall surface and wall sleeve is essential to assure a trouble -free installation. Apply sealant, caulking or equivalent weather proofing material around the perimeter of the wall sleeve (interior & exterior) to eliminate outdoor air and water leaks into the living space. Indoor Wall Hole Sleeve Outdoor Wall Hole Diagram NOTE: Expandable foam insulation may be added to fill large 1 wall gaps Apply per manufacturer's instructions Seal Hole 1 Hole Size O r GREE 15 • • • • • •• • • ••. • • • • • • • • • .• •• • • • • • • • • • • • ••.• • .•• • • • • • •• • , • • . • • •.•• S. • • • • • • • • • • • • . • •• • •• • • • • • • •