Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-18-1102 (2)
INSPECTION RECORD POST ON SITE Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 .Phone: (305)795-2204 Fax: (305)756-8972 INSPECTION REQUESTS: (305)762-4949 REQUESTS ARE ACCEPTED DURING 8:30AM - 3:30PM FOR THE FOLLOWING BUSINESS DAY. Permit NO. RF-4-1 8-1102 Permit Type: Roof- Work Classification: Flat Issue Date: 4/2612018 Roof Expires: 10/23/2018 Parcel #:1132060132920 Owner's Name: KIRK W B WAGAR Job Address: 145 NE 94 Street Miami Shores_ FL 33138- Bond Number: 3729 Owner's Phone: F Jt,r ',PAC,PA Total Square Feet: 400 lselli.tPA. $ 4 'total Job Valuation:,300.00 Contractor(s) M R SANCHEZ CARPENTRY INC Phone (786)355-0212 011,4 tivi A era ip a tern _,or 1. MW§IgiliTS ALLOWED MONDAY THROUGH SATURDAY, ,"�ruaiy CODtractor7:30 SUNDAY - 6:00PM.OR NOHOLIDAYS. WORK IS ALLOWED ON i 4 .' } VitUILDING INSPECTIONS ARE DONE MONDAY THROUGH THURSDAY. ROOFING INSPECTIONS ARE DONE MONDAY THROUGH FRIDAY. NO BUILDING INSPECTIONS DONE ON FRIDAY. (5/0 Ale4 S99 0,41 72()-v-e-c 01,471-fiA)1 COLOR THROUGH CONCRETE TILE OR SOLID CLAY TILE REQUIRED. NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS THE PERMIT APPLICANTS RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. INSPECTION RECORD -STRUCTURAL - INSPECTION DATE INSP Foundation Stemwall Slab Columns (1st Lift) Columns (2nd Lift) Tie Beam Truss/Rafters Roof Sheathing Bucks Interior Framing Insulation ,Ceiling -Grid Drywall Firewall Wire Lath Pool Steel Pool Deck Final Pool Final Fence Screen Enclosure Driveway Driveway Base Tin Cap Roof in Progress Mop in Progress Final Roof Shutters Attachment Final Shutters Rails and Guardrails ADA compliance DOCUMENTS Soil Bearing Cert SoliTreatment Cert .Floor Elevation Survey Reinf Unit Mas 'Cert. Insulation Certificate Spot' Survey Final Survey Truss Certification STRUCTURAL COMMENTS WINDOWS -&DOORS - - - INSPECTION DATE ' INSP Attachment FINAL PUBLIC WORKS INSPECTION DATE INSP Excavation FINAL ELECTRICAL INSPECTION DATE INSP Temporary.Pole .. _ ___ -— _ 30 Day Temporary PoolBonding Pool Deck Bonding Pool Wet Niche Underground Footer Ground Slab Wall Rough Ceiling Rough Rough Telephone Rough ' , Telephone Final TV Rough TV Final Cable Rough Cable Final Intercom Rough Intercom Final Alarm Rough Alarm Final Fire Alarm -Rough Fire Alarm Final Se ice Work With ELECTRICAL COMMENTS INSPECTION FIRE DATE INSP Final Sprinkler Final Alarm FINAL INSPECTION - PLUMBING DATE INSP Rough Water Service 2nd Rough Top Out Fire Sprinklers Septic Tank Sewer Hook-up Roof Drains Gas LP Tank Well _. Lawn Sprinklers Main Drain Pool Piping Backflow Preventor Interceptor Catch Basins Condensate Drains HRS Final FINAL PLUMBING COMMENTS INSPECTION MECHANICAL DATE INSP Underground Pipe Rough Ventilation Rough Hood Rough Pressure Test Final Hood Final Ventilation Final Pool Heater Final Vacuum FINAL MECHANICAL COMMENTS Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Issue Dates 4126/2018 Permit NO. RF-4-18-1' 102 Permit Type: Roof Work Classification: Fiat Permit Status: APPROVED Expiration: 10/23/2018 Parcel Number Applicant 145 NE 94 Street Miami Shores, FL 33138- 1132060132920 Block: Lot: KIRK W B WAGAR Owner Information Address Phone Cell KIRK W B WAGAR 145 NE 94 Street MIAMI SHORES FL 33138-2821 Contractor(s) Phone M R SANCHEZ CARPENTRY INC (786)355-0212 Cell Phone Valuation: Total Sq Feet: $ 4,300.00 400 Type of Work: Re Roof Additional Info: RE -ROOF FLAT Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $3.00 $3.75 $2.50 $1.00 $250.00 $9.00 $4.00 $773.25 Pay Date Pay Type Invoice # RF-4-18-67306 04/26/2018 Cash 04/26/2018 Credit Card Bond #: 3729 Amt Paid Amt Due $ 50.00 $ 723.25 $ 723.25 $ 0.00 Available Inspections: Inspection Type: Tin Cap Final Roof Roof in Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AF construction Authorized Sig oing information is accurate and that all work will be done in compliance with all applicable laws regulating the above -named contract9r to o thew rk stated. / ti/Contrel PCc f`QS April 26, 2018 ture: Owner / Applicant / actor / Agent Date Building Department Copy April 26, 2018 1 0)(10\ 11 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY: INSPECTION LINE PHONE NUMBER: (305) 762-4949 APR 26 FBC 201Y- BUILDING Master Permit No. R-e la- ItOZ PERMIT APPLICATION Sub Permit No. ❑ BUILDING ❑ ELECTRIC 21 ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL PLUMBING ❑ MECHANICAL 0 PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: !/ C7 U City: Miami Shores County: Miami Dade Zip: 7 3 1-3 O Folio/Parcel#: `‘ ` 32 O(P 011—Z°0LO Is the Building Historically Designated: Yes NO Occupancy Type: Load: fsdf Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): V WY-, . U v ( Phone#t/j 4' (o - 943 - 46d U, 3 Address: !Li' M F 9 LA' City: /7% 4 /I / ,t2 fi (le, State: I Zip: 7 / 13 f Tenant/Lessee Name: Phone#: - Email: CONTRACTOR: Company Name:Qi \ • L' S ^3tAkGL C*-iFNZ4j7 DO" C Address: \-4 d N) ) S V / City: l v • 'P ('�\ State: Phone#/ `8 '3SS — Qualifier Name: ACT Phone#:� State Certification or Registration #: CCC\ SR_c1 C Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ L4- 7 % cD Square/Linear Footage of Work: U. O 0 5 Type of Work: ❑ Addition ❑ Alteration 1 ❑ New Description of Work: !.. e - t� C3 o \o\- ❑ Repair/Replace ❑ Demolition Specify color of color thru tile: —� Submittal Fee $ Aid Permit Fee $ a ' CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE$ 2 2_3 (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature/_ / Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of JYr f , 20 )y by Z(-{ s day of �rkCL•\.._ , 20 by q a , who is personally known to , who is ersonnaally knnoo n to me or who has produced as me or who has produced identification and who did take an oath. NOTARY PUBLIC: identification and who did take an oath. Sign:/�0�'`t✓ / �' Sign: Print: Seal: as Print: � .ol\ ram.- Kl\ • >"Y` SANURAM� CSt&' Seal: MY COMMISSION #FF134005 EXPIRES July 15, 2018 (407) 39E-0153 FloridallotaryService.com ******************************i***Ik■*********************************************************************** APPROVED BY �/ / L/I VI Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Notary Public, Sate of Florida at Larg Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name:. 1-&t2K uD A-6 e. Property Address: \L15 Date: Roofing Permit Number: Dear Building Official: te-K , `OAC.DP certify that I am not required to retrofit the roof to wall connections of my building because: a/The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) ignature Print Name „I State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this ✓/h day of41.)fli / /0 ir I Notary Public State of Florida , Co► oti on aG 1752+n Nntor Expires 01/21/2022 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 4/25/2018 Property Search Application - Miami -Dade County Summary Report Property Information Folio: 11-3206-013-2920 Property Address: 145 NE 94 ST Miami Shores, FL 33138-2821 Owner KIRK W B WAGAR Mailing Address 145NE94ST MIAMI SHORES, FL 33138 PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0802 MULTIFAMILY 2-9 UNITS : 2 LIVING UNITS Beds / Baths / Half 4/3/0 . Floors 2 Living Units 2 Actual Area 3,598 Sq.Ft Living Area 3,035 Sq.Ft Adjusted Area 2,979 Sq.Ft Lot Size 12,900 Sq.Ft Year Built • 1928 Assessment Information Year 2017 2016 2015 Land Value $322,062 $322,062 $245,333 Building Value $276,866 $279,196 $281,526 XF Value $41,688 $42,186 $27,602 Market Value $640,616 $643,444 $554,461 Assessed Value $640,616 $609,907 $554,461 Benefits Information Benefit Type 2017 2016 2015 Non -Homestead Cap Assessment Reduction $33,537 Homestead Exemption $25,000 Second Homestead Exemption $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1534165342 MIAMI SHORES SEC 1 AMD PB 10-70 LOTS 20 & 21 BLK 21 LOT SIZE 100.000 X 129 OR 18224-4311 0798 4 Generated On : 4/25/2018 Taxable Value Information 2017 2016 2015 County Exemption Value $50,000 $0 $0 Taxable Value $590,616 $609,907 $554,461 School Board Exemption Value $25,000 $0 $0 Taxable Value $615,616 $643,444 $554,461 City Exemption Value $50,000 $0 $0 Taxable Value $590,616 $609,907 $554,461 Regional Exemption Value $50,000 • $0 $0 Taxable Value $590,616 $609,907 $554,461 Sales Information Previous Sale Price OR Book- Page Qualification Description 03/02/2010 $500,000 27203 0223 Qual by exam of deed 11/01/2005 $870,000 23998 3086 Sales which are qualified 07/01/1998 $0 18224- 4311 Sales which are disqualified as a result of examination of the deed 06/01/1998 $234,500 18191 4725 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: VtN1e-1t , e) Property Address: 11-tC11— CC Roofing Permit Number: Dear Building Official: Date: certify that I have improved the roof to wall connections of the referenced property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential Structures as adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. Signature State of Florida County of Dade Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this % , day of 2/I y 20 If Notary Public, Sate of Florida at Large (SEAL) Revised on 5/21/2009 FINAL COMPLIANCE INTERNATIONAL CODE COUNCIL) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) RECEIVED a MAR' 6 ;018 1 High -Velocity Hurricane Zone Uniform Permit Application Form. I G�'` I Section A (General Information) .... I • • •... 1 Job Address lily Kl� QJ-} aster Permit No. Process No. .. . 1 • ••.:• • Contractor's Name (`�\ • S`'1NC�=Z �A�Q�:N 7�y / I •. dL/ C • • ••.•• • " ' • • • ; • mop 000000 ••• •• • • • 1 • .... • •• ••• • • • • •• ...r. ROOF CATEGORY " • • +• • ••.••. •.••.• • `• Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adht3si�je Set Tjles • 0 Asphaltic Shingles ' • •` • • P 9 ❑ Metal Panel/Shingles 0 Wood $hinglr VShakeS IDPrescriptive BUR-RAS 150 ' • • • : •I �: • • . •• • 1 ❑ Recovering 1 1 1 Section B (Roof Pia 1 Sketch Roof Plan: Illustrate all levels nd sections, roof drirg e , ow scuppers and overflow drains. Include dimen- I sions of sections and levels, clearly i eltify •1 jt x • f , 1 attee pre sure ones and location of parapets. I 0 New roof CIRepair Low Slope Roof Area (SF) Lffl ROOF TYPE IDMaintenance ROOF SYSTEM INFORMATION Steep Sloped Roof AREA (SSF) 1 Reroofing Total (SF) ' l0o 4 / , w ( , .i J v u1 S o• S C... [P /////:74 ;,--1 ?:' / / 4. ii w llLoor , f - ip eie od,., :3 - - FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to license Agreement. No further reproductions authorized. 1 1 I 1 i i 1 1 1 .1 1 I I 1 1 1 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING ••CONSIDERATIONS • •'•••• •••• 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor td•prtlide the owner with •.... the required roofing permit, and to explain to the owner the content of the section. The pr*oiIbtcfrt of Section R4402 • govern the minimum requirements and standards of the industry for roofing system install tions.Additi8rt311y'the • •• . • following items should be addressed as part of the agreement between the owner ant thg �Qntractor. The 6/her's • •; • • initial in the designated space indicates that the item has been explained. • ••• • • •; • • •.... •• • .•••.• ...... . • •• • • 2. w Renailing wood decks: When replacing roofing, the existing wood rgo�f deck nay h aave to • be renailed in accordance with the current provisions of Section R4403. (The roQftlecR is us�aflr• • • •• • • • •. concealed prior to removing the existing roof system). • • • 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. bC 1AJ Overflow scuppers (wall outlets): It is' required that rainwater flows off so that the roof is not overloaded from ,a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) aie not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. ne 1Agent's Signature Date Property Address Revised on 7/9/2009 LD;07/01/2015; Contractor Signature 4/2 Y/( Date Permit Number Florida Building Code 5th' Edition (2014) High Velocity Hurricane Zone Uniform Permit Application Form 1 23 01-48 8/15 PAGE 3 Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, i entify as NA') System Manufadu 4 NOA No.: oz Design Win Pressures, From RAS 128 or Calculations Pmax1: Pmax2: 7/ 7 Pmax3/1144) Max. Design Pressure, From the Specific NOA .4" 7 $ System: ✓ Deck Type: Gauge[Thickl : �� �� iD/At Slo orBase heet o ftniar.mt.e.er4s. Anch o. of Ply(s): An h r ase Sheet st /Bon i ��r�s ' Insulation Base Laye ( - Base Insulation Size a Base Insulation F(tener/Bonding Mat'al: Top Insulation Layers d 4 Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Materia Ply Sheet(s).& No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Top Ply F Surfacing: Field: f ' Perimeter. Comer. c@ Lap, # Rowa •• " oc (d3 Lap, # Rowi • • • oc © Lap, # Rowi Number of Fas Board Field Illustrate Co Details as A ble: c •• . ••• ners der insulatlbn • • ••• • . • ••••••. •••• • omer • • • • ...•.. .. . No'ed anf! •• • • . • Wood blocking, Gutter, Edge Terminatron, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. •••••• • .• • • •.4 ••• • • ••.•• I • ••••• ••.••• •• OOOOO• • • •••.•• • . lea o/,40 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: " www.tniamidade.2ov/economv ••.. .• • • • • • • • • •• •••.• •...•• • Sill.. • This NOA is being issued under the applicable rules and regulations governing the us%bf tdiastruct n • materials. The documentation submitted has been reviewed and accepted by Miami-.Daa2 County RER • • • Product Control Section to be used in Miami Dade County and other areas where allowe'b'}i;the . • • : • • Authority Having Jurisdiction (AHJ). " • • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade t ouifit‘Prodtlet Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami QadgCount4""• reserve the right to have this product or material tested for quality assurance purposes.'If this produ: t.or.. material fails to perform in the accepted manner, the manufacturer will incur the expense of such te9ttng and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoidu Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, skate and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed a`nd there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0611.01 and consists of pages 1 through 30. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY APPROVED NOA No.:.14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 • Page 1 of 30 ••••.• . • • •.•••• • . ...... • . ..•.. • • ••.S• OOOOOO • . ••.... • . ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -75 psf. • • • • • •.•..• • • • Product Matrix' 102 SBS Membrane Adhesive TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLINIt: • • • • TABLE 1 Test Specification ASTM D3019 GAFGLAS® #75 Base Sheet GAFGLAS® #80 Ultima' Base Sheet GAFGLAS® FlexPly" 6 GAFGLAS® Ply 4 GAFGLAS®Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM BUR Mineral Surface Cap Sheet GAFGLAS® Stratavent® Eliminator' Perforated Venting Base Sheet GAFGLAS® Stratavent® Eliminator' Perforated Nailable Venting Base Sheet Ruberoid® SBS Heat -Weld' Smooth Ruberoid® SBS Heat -Weld' Granule RoofMatch' • SBS Modified Granular Ruberoid® SBS Heat -Weld' 170 FR MIAMI•DADE COUNTY APPROVED (1 Dimensions 5 gallons 39.37" meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 107 sq. ft. (9.9 m2) 39.37" (1 meter),Wide ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 ASTM D3909 ASTM D3909 ASTM D4897 ASTM D4897 ASTM D6164 ASTM D6164 ASTM D6164— ASTM D6164 • •••• • •+•••• • Prr8htt- •• • •• • Description • • • •••••- Fiber reinforced rubb& 7 cold�p ie.l • adhesive for modified.biitmen roof • systems. • • - Type II asphalt imgregpatgd and:coated' glass mat base sheet' • • •+ . Type II asphalt impregnated and &elate& fiberglass base' sheet. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCoteTM Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. A nailable, fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -woven polyester mat coated with polymer -modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with SBS polymer -modified asphalt and surfaced with colored mineral granules. Non -woven polyester mat coated with fire retardant polymer -modified asphalt and surfaced with mineral granules. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 2 of 30 •••••- • • • •••••- •..... • • ••-•- ••••• •-••-- • • •••--• • • •---•• • • Product Ruberoid® SBS Heat -Weld'"' Plus Ruberoid® SBS Heat -Weld" Plus FR Ruberoid® EnergyCap'" SBS Heat -Weld' Plus FR Ruberoid® SBS Heat-WeldTM 25 Ruberoid® Mop Granule Ruberoid® Mop Smooth Ruberoid® Mop Plus Ruberoid® Mop 170FR Ruberoid® Mop FR Ruberoid® Torch Smooth Ruberoid® Torch Granule Ruberoid® EnergyCap- Torch Granule FR Ruberoid® EnergyCap'" Torch 'Granule Plus FR RoofMatch"" APP Modified Granular Ruberoid® Torch FR MIAMI•DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (I meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37 (1 meter) Wide 39.37 (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (I meter) Wide 107 sq. ft. (9.9 m2) 1 meter (39.37") Wide Test Specification ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 , ASTM D6164 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 Product Description Non -woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated Aitb,,Qre retardant polymer-Irlpdi fed asphal>,agcj • surfaced with mineraPgranales. ..•• Non -woven polyesteett ?eoatedwiZla fire retardant polymer-rno'cl'ifitQ asphalt and surfaced with mineral 'ranules aQd}vit1.1 factory applied Enelg lAe. Nonwoven polyester tllitcoated.wit'• polymer -modified asltiand smooth surfaced. ' ' ' • Non -woven polyester mat coatei Willa • polymer -modified a.phal$and surig4 with mineral granules. '..'•' Non -woven polyester mat coated with polymer -modified asphalt and smooth surfaced. Non woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer -modified asphalt and surfaced with mineral granules. Non ;woven polyester mat coated with APP modified asphalt and smooth surfaced. Non -woven polyester mat coated with APP iodified asphalt and surfaced with mineral granules APP modified cap membrane with a torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCoteTM. APP modified cap membrane with a torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCotet. Non -woven polyester mat coated with APP polymer -modified asphalt and surfaced with colored mineral granules. Non -woven polyester mat, coated with fire retardant asphalt modified bitumen membrane with granule surface. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 3 of 30 000000 • • • ••..•• • • ...... • • • • 00000 ..•... • • •••••. • • •••.•• • • Product Ruberoid®20 Ruberoid®30 Ruberoid® 30 FR Ruberoidm EnergyCap' 30 FR SBS Membrane Ruberoid® Dual FR Topcoat® Elastomeric Roofing Membrane , Topcoat® MB Plus Topcoat® Surface Seal SB FireOut ' Fire Barrier Coating VersaShield° Fire -Resistant Roof Deck Protection MIAMI•DADE COUNTY APPROVED Dim ensions 1 meter (39.37") Wide 1 meter (39.37") Wide 1 meter (39.37") Wide 1 meter (39.37") Wide 39.37" (1 meter) Wide 1, 5 or 55 gallons 5 or 55 gallons 5 gallons 5, 55 gallons 42" x 100' rolls Test Specification ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6162 ASTM D6083 Proprietary ASTM D6083 Proprietary ASTM D226 Product 'Description SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules.. •.... • Non -woven fiberglass n3at coated:witi fire retardant, polymer ernQdi lied asphnk and surfaced with mirt i'gtanules. • Non -woven fibergl"aSS that coatetl.wttb fire retardant, polymer!th ified aslphatt and surfaced with minerariianules.arictWith factory applied EaryCote. Non -woven polyl sterar�ti fiberuglas ;mat coated with file rgtarda it, polyrtert • • modified asphalt and Suefaced viith . • mineral granules. An acrylic, water based elastomeric membrane system designed to protect various types of roofing surfaces. Water based, low VOC primer used to block asphalt bleed -through. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. Low VOC, water -based fire barrier coating. Non -Asphaltic, fire resistant fiberglass - based underlayment. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 4 of 30 APPROVED INSULATIONS: Product Name EnergyGuardT" Polyiso Insulation EnergyGuardT" RA Polyiso Insulation EnergyGuardTM RN Polyiso Insulation EnergyGuardT" Perlite Recover Board EnergyGuard' Perlite Roof Insulation EnergyGuardTM RA Composite Polyiso Insulation Structodek® High Density Fiber Board Securock® Gypsum -Fiber Roof Board APPROVED FASTENERS: Fastener` Number 1. 2. 3. 4. Product Name Drill-TecT" #12 Fastener Drill-TecT" #14 Fastener Drill-TecT" XHD Fastener Drill-TecT" AccuTrac®Flat Plate 5. • Drill-TecT" ASAP 3S 6. Drill-TecT" AccuTrac® Recessed Plate Drill-TecT" 3" Steel Plate 8. Drill-TecT".3" Standard Steel Plate MIAMI•DADE COUNTY APPROVED Table 2 Product Description Polyisocyanurate foam insulation , Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate/wood fiberboard or perlite composite High density wood fiber Gypsum board TABLE 3 Product Description Carbon steel fastener used in steel or wood decks. Manufacturer (With Current NOA) GAF ,... . • GAF •••• .. • •••• GAF .... • . •••• GAF• • •• . . . •••• GAF. •• ..•..•GAF •..• . Blue Ridge Fiber$avc ,Inc: . Unit'✓rd,S'tafes Gypsum Corp. . Dimensions Various Carbon steel fastener used Various in steel, wood or concrete decks. Carbon steel extra heavy Various duty fastener used in steel decks. AZ -SS aluminized steel 3" x 3" plate for use with Drill- TecT" #12 Fastener, Drill- TecT" #14 Fastener and Drill-TecT" #15 Fastener. Drill-TecT" #12 fastener Various with Drill-TecT" 3" Standard Steel Plate. Galvalume Steel plate for 3" x 3" use with Drill-TecT" fasteners. Round galvalume steel 3" stress plate for•use with Drill-TecT" fasteners. Round galvalume plated steel stress plate with reinforced ribs for use with Drill-TecT" fasteners. 3" .. • Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF GAF GAF NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 5 of 30 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories Trinity Engineering IRT-ARGON Inc. Trinity I ERD MIAMI•DADE COUNTY APPROVED Test Identifier 3001276 1 B9A8.AM 3D4Q2.AM, 0D 1 A8.AM R1306 4483.04 97-1 02-005 02-014 01-039 G30250.02.10-2 G30250.02.10-3-R2 G31360.03.10 G33470.01.1,1 G34140.04.11-2 G34140.04.11-4-R2 G34140.04.11-5-R3 G40620.07.12-2 G40630.01.14-1 G4063 0.01.14-2A G40630.01.14-2A-1-R I G40630.01.14-2B-R 1 G40630.01.14-2C G40630.03.14 G43190.03.14-1 G43190.03.14-2 043190.05.14-R 1 G43190.11.13-1 G43610.01.14 G46160.02.15-2D G46160.03.15 G46160.09.14-2A G46160.09.14-3A 046160.09.1.4-3B G46160.09.14-3 C G46160.12.14-3E G6850.08.08 G6850.08.08-RI G6850.10.08 G6850.11.08 SC6870.08.14-R 1 ASTM D6164 ASTM D6163 ASTM D4601 ASTM D4897 ASTM D6222 ASTM D6163 ASTM D5147 ASTM D6164. ASTM D6164.. ASTM D6164 ASTM D5147 ASTM D5I47 ASTM D5147 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6163 ASTM D6163 ASTM D5147 ASTM D6164 ASTM D6164 ASTM D5147 ASTM D6164 ASTM D6163 ASTM D6164 ASTM D6222. ASTM D6222 ASTM D3909 Description FMRC 4470 FMRC 4470 FMRC 4470 FMRC 4470 UL 790 TAS 114 Date 01 /28/99 09/04/97 04/310 W. �•, ••.104/0l%1 .. •• 07/22f19 • . . •.: 06/06b97 . . • . • • • • • • • •• TAS 114 • • 03/0jf07•- TAS 114 • • • • 04/08702 • TAS 114 03/01/02' • • ASTM D6222 • • 11/1171.66. ASTM D3909 •••• • 06/001•5••- ASTM D6164- 03/31f110 • 01/13/11 04/25/11 6/4/2015 6/4/2015 '07/17/12 •01 /06/14 0.1 /07/14 04/10/14 '01/16/15 01/07/14 :03/06/14 03/06/14 `03/06/ 1.4 05/20/14 11/15/13 ,01 /22/ 14 02/03/15 03/11/15 09/09/14 09/09/14 09/09/14 09/09/14( ' 12/29/ 14 08/01 /08 04/14/11. 10/06/08 02/17/09 09/04/14 NOA No:: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 6 of 30 1 EVIDENCE SUBMITTED: (CONTINUED) Test Agency PRI Construction Technologies LLC. Momentum Technologies, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier GAF-084-02-01 GAF-122-02-01 GAF-245-02-01 GAF-276-02-01 Rev GAF-306-02-01 GAF-314-02-01 GAF-315-02-01 GAF-369-02-01 GAF-464-02-01 GAF-499-02-01 GAF-500-02-01 AX04C9A Description ASTM D6083 TAS 139 ASTM D6083 ASTM E2178 ASTM D6083 ASTM E96 ASTM D2178 ASTM D2178 ASTM C1289 ASTM C1289 ASTM D6083 ASTM D6083 ASTM D6162 • • - • - • •• • Date 07/08/05 05/07/06 06/1.0!1t9 •. 01 /04T? I • •••• • • 07/d7/T f 08/23/1 r 08/23/i1.• 10/22/1; . 02/C/4/14 03/12/14 ▪ 03/142/14. 06/05`Q9. • •••• • • •••- NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 7 of 30 • • • • • • • • • • • - • •• • • • Membrane Type: APP/SBS Heat Weld' Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. .... All General and System Limitations shall apply. • •• s • • • • . • .l Fire Barrier: FireOut?' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck .... (optional) Protection or Securock® Gypsum -Fiber Roof Board. • Base sheet: GAFGLAS® #80 UltimaT' Base Sheet, GAFGLAS® Stratavegt'e')alNgiinator• • • Nailable Venting Base Sheet, Ruberoid® Mop Smooth, Ruberdit1 20, Rulferolti° SBS Heat -Weld' Smooth or Ruberoid® SBS Heat -Weld' 25 Sc'hariicallyia.:•• • fastened to deck as described below; Fastening .GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6, GAFGLAS® #75 BaseShee q,r gt% Options: of above base sheets attached to deck with approved annular:ings'hank nfils and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows:1?•'•. o.c. in the field. (Maximum Design Pressure —45 psf. See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS F1exPly' 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecT" #12 Fastener, Drill-TecT" #14 Fastener or Drill-TecT" XHD Fastener and Drill -Tee' 3" Steel Plate, Drill- TecT' AccuTrace Flat Plate or Drill -Tee' AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —4S psf. See General Limitation #7) GAFGLAS' FlexPlyT"' 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf See General Limitation #7) GAFGLAS® #80 Ultima' Base Sheets, Ruberoide20, Ruberoid®Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecTm #12 Fastener, Drill-TecT" #14 Fastener or Drill-TecT' XHD Fastener and Drill-TecT" 3" Steel Plate, Drill-TecT" AccuTrace Flat Plate or Drill -Teem AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #7) MIAMI•DADE COUNTY APPROVED • NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 28 of 30 Ply Sheet: Fastening Any of above base sheets attached to deck approved annular ring shank nails and Options: 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" (Continued) lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psi: See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Tee' #12 Fastener, Drill-TecTM #14 Fastener or Drill-TecTM XHD Fastener and Drill-TecTM 3" Steel Plate, Drill -Tee' AccuTrac® Flat Plate or Drill-Tec•• AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One ''''�,• rc�y is. ir:the 2" side • • • lap. The other rows are equally spaced approximately 9" o.cintrgeld ooJh • sheet. • • • (Maximum Design Pressure —75 psf. See General LimitationdlJ). • • • • • • •• • • (Optional except over Ruberoid® Mop Smooth, Ruberoid® 20 ku eroid® S'BS • ....•..• .. . Heat-WeldTM Smooth or Ruberoid® SBS Heat -Weld' 25) Oneavpte plies•.• • .GAFGLAS® Ply 4 or GAFGLAS® FlexPlyTM 6 sheet adhered ylgfulJ moppingof. •• approved asphalt applied within the EVT range and at a rate of 20-4D lbs./sq. or. • Ruberoid® Torch Smooth torch applied according to manufacturer's appliclfi5n•• •• instructions. .. • • • • • • One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, RoofMatch'" • APP Modified Granular, Ruberoid® EnergyCapt Torch Granule FR, Ruberoid® EnergyCapTM Torch Plus FR, or Ruberoid® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid® SBS Heat-WeldTM Plus, Ruberoid® SBS Heat- WeldTM Plus FR, Ruberoid®.SBS Heat-WeldTM l 0 F , Ruberoid® EnergyCapTM SBS Heat-WeldTM lus FR, Ruberoid® SBS Heat-WeldTM Granule, Ruberoid® SBS Heat-WeldTM Smooth and Ruberoid® SBS Heat-WeldTM 25 applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat® Membrane, Topcoat® MB Plus (to be used as a primer with Topcoat® Membrane) or Topcoat® Surface Seal SB applied at 1 to1.5 gal./sq. Maximum Design Pressure: See Fastening Options MIAMI•DADE COUNTY APPROVED r • NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 29 of 30 WOOD DECK SYSTEM LIMITATIONS: I A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPlyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeck® Roof Board or'/z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: ; . • • • • • 1. Fire classification is not part of this acceptance; refer to a current Approved Mat rtg )Materials.... . • Directory for fire ratings of this product. . . : •. • 2. Insulation may be installed in multiple layers. The first layer shall be attachedinampliance with • • Product Control Approval guidelines. All other layers shall be adhered in a full teeming of:•. •. • • approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., oi•itmeehanicalfy • • attached using the fastening pattern of the top layer • •. • . • 3. All standard panel sizes are acceptable for mechanical attachment. When a lfeii iti•a roved•• • • asphalt, panel size shall be 4' x 4' maximum. •pP pp 4. An overlay and/or recovery board insulation panel is required on all applications over losecf eel+.• • • foam insulations when the base sheet is fully mopped. If no recovery board is us jhth:.base stiiet• • • shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; oi•ztrip. • mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to,a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 11 l and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED . NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 30 of 30 • TGFU:R14153 - Roofing Systems Pagel of 1 SINGLE PLY MEMBRANE ROOFING SYSTEMS (MODIFIED BITUMEN) Unless otherwise Indicated phenolic insulation may be used in any of the following systems. Unless otherwise indicated any of the following Single Ply Membrane Systems may utilize multiple layers of Ruberoid® Membrane. "GAF Premium Aluminum Roof Coating" may be used on any of the following Classifications with inclines not exceeding 1/2-in. "GAF Weater Coat Emulsion" may be used on any of the following noncombustible Classifications with Inclines not exceeding 1/2-in. a "Ruberold® Modified Bitumen Adhesive" or Monsey Corp. "MBA Gold" or Karnak "No. 81" adhesives may be used in any of the following noncombustible deck Classifications, "GAFGLAS® #80 Premium Base Sheet" may be used In any of the following systems. •••• • • • • •••• (Optional) Noncombustible deck classifications are applicable for use over combustible (15/32-in. minimum plywoodaslecki when 1/2,in►• • (minimum) gypsum board or 1/4-in. (minimum) Georgia-Pacific Gypsum LLC "DensDeck ® Roofboard," "DensDeck PrimeQ RoofboarcP or "DensDeck DuraGuard" Roofboard" are used directly over the deck with all joints staggered 6-in. (minimum) frorii til 4eo' i joints, • • • • A vapor barrier may be optionally Installed under all systems utilizing any "EnergyrGuard®" type Insulation, "GAFGI ASV Perlite" nay be used as an option over any "EnergyGuard"" type insulation. "GAFGLAS® Stratavent Perforated Base Sheet "may be utilized�s anadditiorierply nany of the following systems. • • • • • • • The followingmembranes may be used Interchangeably within their own group:• • • • 9 Y •• ••• A. "Ruberold® Torch Granule" or "Ruberoid® Torch Granule Plus" or "Ruberold® Torch Granule 1" or "Rutjejcgila j'orch 180"ore • "ROOFMatch" APP Modified Granular" or "Tri-Ply® TP-4G", • • • • B. "Ruberoid® Mop Smooth" or "Ruberoid® SBS Heat Weld Smooth" or "Ruberold® 601 Cap Plus" or "Rutieroidc 30". • • • C. "Ruberoid® Mop Granule" or "Flex PRF" or "Ruberoid® Mop Plus Granule" or "Ruberoid® SBS Heat WeldGranule" or • • • • • "Ruberoid® SBS Heat Weld Plus" or "ROOFMatch" SBS Modified Granular" or "Tri-Ply® SBS Modified Bitumen Membrane"' • • • • • D. "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR", E. "Ruberoid® 30 FR" or "Ruberoid® 30 FR HT" or "Ruberoid® EnergyCap" SBS 30 FR". F. "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberold® SBS Heat Weld 25." G. "Ruberoid® SBS Heat Weld 170 FR", "Ruberoid® EnergyCap" SBS Heat Weld Plus FR" or "Ruberoid® SBS Heat Weld Plus FR". H. "Ruberold® Torch Smooth" or "Tri-Ply® TP-4". I. "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Dual Smooth". J. "Ruberoid® Mo'p Smooth" or "Ruberoid® Mop Smooth 1.5". Unless otherwise Indicated, the Modified Bitumen (Granule) membrane may be surfaced with "TOPCOAT® Fireshield MB" at 21/2 to 3.0-gal/100- ft2, and the incline of the resultant system would be increased to a 3/4-in. incline. But if the incline of the Classified system is greater than a 3/4-in'. incline, the Incline of the roofing system would be maintained when surfaced with "TOPCOAT® Fireshield MB" at 21/2 to 3.0-gal/100-ft2. Unless otherwise indicated "Ruberoid® EnergyCap" SBS 30 FR" is an acceptable alternate for "Ruberold® 30 FR" or "Ruberoid® 30 FR HT' or "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" in any applicable Classification. ••• • • • • ••• • • http://database.ul.com/cgi-bin/XYV/template/LI SEXT/1 FRAME/showpage.html?name=T... 6/29/2017 ,TGF - Roofing Systems Page 1 of 1 Incline: 1/2 — Two or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" mechanically fastened. ne: — One ply "Ruberoid® SBS Heat Weld Plus FR" or "Ruberoid® SBS Heat Weld 170 FR" heat welded in place. • • • • • • • • t • • • • • • • • •• • • • • • • • • • • • • • • • • •• • • • • • • • • • • • •• • • • • • • • • • •• •• •• • • • • • • • • • • • • • • • • • • • • , • • • • •• • •• • • • • • • http://database.ul. com/cgi-bin/XYV/template/LI SEXT/ 1 FRAME/showpage.html?name=T... 6/29/2017 Miami Shores Viitage. Building Department 10050 N.E.2nd'Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE'M4TIGATIQN,.•. RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STFdi6TUREiPURSUAN• TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: , (:,) a G A e) Property Address: ti 2-kq-trcM Roofing Permit Number: • • • • • .. • • • .. • .... . .. ..•.•. . . . .. Date: •• "• • . •.. . • . • ▪ .. .. • .. . • .. .. • . Dear Building Official: I KleM uJA certify that I have improved the roof to wall connections of the referenced property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential Structures as adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this % ib day of Apia / 20 /fr 9 Notary Public, Sate of Florida at Large (SEAL) Revised on 5/21/2009 Notary Public State of Florida . Lourdes Lurigados +1 My Commission OG 175210 �1� Expires 01/21/2022 FINAL COMPLIANCE • Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.897? .•.. .• • •••• OWNERS'S AFFIDAVIT OF EXEMPTIO• N;,•;, .. ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EMOTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES '...• .• '..• PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: ki.tax uj 1e Property Address: \ Lks3 e •... • • • • • •• •• •• • sate: , • • • • • • • • .• • • • • • • • • • • • •• • •• • • • • • • •. • Roofing Permit Number: Dear BuildingrOfficial: I %ILA , UACaP-( certify that I am not required to retrofit the roof to wall connections of my building because: l f he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) ignature Print Name • State of Florida County of Dade The undersigned, being the first duly sworn, deposes�and says that he/s a is the owner for the above property mentioned. 1'day of Sworn to and subscribed before me this Notary Public, Sate of Florida at Larg 6J %;, Notary Public State of FloridaLourdes 1 My Commesson OG 7521t1 , Expires 01/21/2022 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009