RC-18-855 (2)VSE Project Number: U1869-1609-181 March 29, 2018 Prosolar Systems LLC 725 W Las Olas Blvd Fort Lauderdale, FL 33312 •••• • • • • • • • • •• •• • , • • • • • • • • • • • • • • • • • • •••• • • • • • • • • • • • • • • • •• •• REFERENCE: John Forbes Residence: 304 Northeast 99th Street, Miami Shores, FL 3313i • Solar Array Installation To Whom It May Concern: We have reviewed the documents provided by Prosolar Systems LLC relating to the -installation of the solar array at the above -referenced site. Based upon our review, it is our conclusion that the installation of the solar array on this existing roof will not adversely affect this structure. It is our understanding that the structural components of the existing roof framing are. in good condition and free of damage. The design of the solar panel racking (mounts, rails, etc.) is by the manufacturer or contractor. • • • • • :• •• • • • • • • • • • • • • • • • •• • • • Design Parameters Code: Florida Building Code, 2017 Edition (2015 IBC) Risk Category: II Design wind speed: 175 mph (3-sec gust) per ASCE 7-10 Wind exposure category: C Ground snow load: 0 psf Existing Roof Structure • Roof structure: 2x4 manufactured trusses @ 24" O.c.STRUCTURAL REVIEW Roofing material: clay Spanish tile APPROVED. Roof slope: 30° Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" embedment into framing at max. 48" O.C. along rails" •• • • • • •• • Conclusions Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight of the solar array is 3 psf or less. In the area of the solar array, other live loads will not be present or will be greatly reduced (2017 FBC, Section 1607.12.5). The gravity loads in the area of the solar array are decreased; thus, the stresses of the structural elements are, decreased. Therefore, the requirements of Section 807.4 of the 2015 IEBC are met and the structure is permitted to remain unaltered. 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com VSE Project. Number: U1869=1609-181 John Forbes Residence 3/29/2018 The solar array will be flush -mounted (no more than 6" above the roof surface) and parallel Co the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition.of the proposed solar array414, ible. The attached calculations verify the capacity of the connections of the solar array to the existing t4df *ainst wigcj igplifl), the governing load case. Because the increase in lateral forces is less than 10%, this addition meats ihe.requireuiuts of the exception in Section 807.5 of the 2015 IEBC. Thus the existing structure is permitted to remain unelteilede .... . . Limitations .... . . .. .. .... . . .. • . . . . .. . Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry -wide methods and applicable safety standards. J'he .ontractcrsfiaN'notify. . Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the -Built coni,gion of the. structure and the condition described in this letter be found. Particular attention must be paid to the maximum. allowable spacing of connections and the location of solar panels relative to roof edges. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site -specific design parameters, and solar panel configuration match the 'description of .the span tables., Electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING, LLC FL Firm License: COA 26626 03/29/2018 Jacob Proctor, P.E. Project Engineer Enclosures JSP/ych 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801)_990-1775 / F (801) 990-1776 / www.vectorse.com .VECT R E rl O I rl E E R S PROJECT: John Forbes Residence JOB NO.: U1869-1609-181 SUBJECT: WIND PRESSURE Components and Cladding Wind Calculations Label: SITE -SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 175 Exposure Category: C Risk Category: ' II ADDITIONAL INPUT & CALCULATIONS: . . . .. . Note: Calculations p2PP CE 7;1e••• •.•• •••• • . • • • . .. .. .. .. . • .. . • . ._:—� • 0.6 ... •• . . I. • Height of Roof, h [ft]: 15 (Approximate) Comp/Cladding Location: Gable Roofs 27° < 9 <_ 45° Enclosure Classification: Enclosed Buildings Zone 1 GCP: 1.0 Figure 30.4-2C (enter largest abs. value) Zone 2 GCP: 1.2 (enter largest abs. value) Zone 3 GCP: 1.2 t (enter largest abs. value) a: 9.5 Table 26.9!-1 z9 [ft]: 900 Table 26.9-1 Kh: 0.85 Table 30.3-1 KZt: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 56.6 Equation 30.3-1 GCP;: 0 Table 26.11-1 (largest abs. value) OUTPUT: p = qh [(GCc )— (GC, Equation 30.9-1 Zone 1 Pressure, p [psf]: 56.6 psf (1.0 W, Interior Zones*) Zone 2 Pressure, p [psf]: 67.9 psf (1.0 W, End Zones*) Zone 3 Pressure, p [psf]: 67.9 psf (1.0 W, Corner Zones* within a) (a= 3 ft) .,%1* E rl O 1 rl E E R S PROJECT: John Forbes Residence JOB NO.: U1869-1609-181 SUBJECT: SEISMIC LOADS • . . • COMPARE WIND & SEISMIC LOADS FOR CONNECTION (1 Sq. Ft.'Section) . Wind Load, W: ••••• • .... Wind pressure, p: Height, h: Width, w: Fperp: Seismic Load, E: Risk category: Seismic Design Category: I. Site Class: Rp: Ss: 33.9 1.0 1.0 33.9 A 1.00 D 1.5 0.043 0.021 .... • . •... . . •••• .... . • .... • . . • • psf (Zone 1: 0.6 W from wind pressure cakuilation) •..•.•• • ft • • .•• ft • • • • . lb (Uplift) Wind Controls Connection Desiun Fa: Fv: SMS: SM1: SDS: SDI: ap: 0.7 * Fp,min: z: ft 0.7 * Fp,max: h: ft 0.7 * Fp,vert: z/h: 0.7'* Fp,long: 0.7*Fp,perp: CHECK INCREASE IN OVERALL SEISMIC LOADS! SEISMIC: 1.0. 1.0 1.0 1.6 2.4 0.068 0.050 0.046 0.033 -0.029 0.153 0.019 0.076 0.0548 Estimated Roof Dead Load 27 Max. % of Roof w/ Panels 33 Dead Load from Panels 3 Total Dead Load 27.6 Increase in Dead Load ` 3.7% •• . lb lb lb lb lb (uplift) psf psf psf (DL+% of roof w/ Panels*Panel DL) Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 3.7%. Because the increase is less than 10%, this addition meets the requirements of the exception in Section 807.5 of the 2015 IEBC. Thus the existing structure is permitted to remain unaltered. 1 /ECT En o I n E E R s' PROJECT: John Forbes Residence JOB NO.: U1869-1609-181 SUBJECT: CONNECTION Lag Screw Connection Capacity: Lag Screw Size [in]: Cd: Embedment' [in]: Grade: Capacity [lbs/in]: Number of Screws: Prying Coefficient: Total Capacity [Ibs]: 5/16 1.6 .. 2.5 NDS Table 2.3.2 SPF (G = 0.42) 205 1 1.4 586 NDS Table 12.2A Demand: (Zone 1 2 3 • . ••S• • .• •. . .... • .... •... • . Pressure Max Ma ..Trib. �'t (0.6 Wind) Tributary '' 1ei2 Niax. l�plift • • (psf) Width (ft) FQgCeXlbs) �� .' . • 33.9 4.0 • 11.0 ;••S79 40.7 4.0 .• en T1 •.448 a Am 40.7 4.0 11.0 "4248 Demand< Capacity: CONNECTION OKAY 1. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. 2. 'Max. Trib Area' is the product of the 'Max. Tributary Width' (along the rails) and 1/2 the panel width/height (perpendicular to the rails). '*VIE .TORE E n o i n E E R s PROJECT: John Forbes Residence JOB NO.: U1869-1609-181 SUBJECT: GRAVITY LOADS . • •• CALCULATE ESTIMATED GRAVITY LOADS ROOF DEAD LOAD (D) Roof Pitch/12 Clay Spanish Tile 1/2" Plywood Framing Insulation 1/2" Gypsum Clg. M, E & Misc ROOF LIVE LOAD (Lr) Increase due to pitch • • • • • • . • • •• • .••• •.•• • Oitginti loddfig • • • • • • • • • • • DL PV Array DL 6.9 18.5 1.2 3.0 0.5 2.0 1.5 27 3 psf psf psf psf psf psf 1.15 1.15 • • .. •• � •‘16.0 • 1.0 • • • • •• • • • • • • •• • • psf • psf • S. • • • • • .• Existing Design Roof Live Load [psf] Roof Live Load With PV Array [psf] SNOW LOAD (S): 20 0 Existing ASCE 7-10, Table 4-1 2017 FBC, Section 1607.12.5 w/ Solar Panel Array Roof Slope [x:12]: Roof Slope [°]: Snow Ground Load, pg [psf]: Terrain Category: Exposure of Roof: Exposure Factor, Ce: Thermal Factor, Ct: Risk Category: .Importance Factor, Is: Flat Roof Snow Load, pf [psf]: Minimum Roof Snow Load, pm [psf]: Unobstructed Slippery Surface? Slope Factor Figure: Roof Slope Factor, Cs: Sloped Roof Snow Load, ps [psf]: Design Snow Load, S [psf]: 6.9 6.9 30 30 0 0 C C Fully Exposed Fully Exposed 0.9 0.9 1.1 1.1 II II 1.0 1.0 0 0 0 0 No No Figure 7-2b Figure 7-2b 1.00 1.00 0 0 , 0 0 ASCE 7-10, Section 7.2 ASCE 7-10, Table 7-2 ASCE 7-10, Table 7-2 ASCE 7-10, Table 7-2 ASCE 7-10, Table 7-3 ASCE 7-10, Table 1.5-1 ASCE 7-10, Table 1.5-2 ASCE 7-10, Equation 7.3-1 ASCE 7-10, Section 7.3.4 ASCE 7-10, Section 7.4 ASCE 7-10, Section 7.4 ASCE 7-10, Figure 7-2 ASCE 7-10, Equation 7.4-1 1 WECT R E fl O i n E.: E R S 1 PROJECT: John Forbes Residence JOB NO.: U1869-1609-181 SUBJECT: LOAD COMPARISON •. • • Summary of Loads D [psf] Lr [psf] S [psf] Maximum Gravity'Loads: D + Lr [psf] D + S [psf] Maximum Gravity Load [psf]: Existing With PV Array 27 30 20 0 0 0 ' Existing 47 • • •••• • •• •• •• • •••• • • • ••.• • • • *oils :••• • • • • •••• •••• • • • • • • • •• •• s• •• • • • • • • • • • • • • • • • • • With PV Array •••• •• • • • ASCE 7-10, Section'2s.1 ASCE 7-10, Section 2.4.1 30 27 30 47 30 Ratio Proposed Loading to Current Loading: 64% OK The gravity loads in the area of the solar array are decreased; thus, the stresses of the structural elements are decreased. Therefore, the requirements of Section 807.4 of the 2015 IEBC are met and the structure is permitted to remain unaltered. GENERAL NOTES 1.1.1 PROJECT NOTES: 1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURERS'S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE CODES. ■ 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY -INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP ■ COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. I 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 4 ■ ■ 1.2.1 SCOPE OF WORK: 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID -TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF -MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.3.1 WORK INCLUDES: 1.3.2 PV ROOF ATTACHMENTS - UNIRAC STANDOFF 1.3.3 PV RACKING SYSTEM INSTALLATION - UNIRAC STANDARD 1.3.4 PV MODULE AND INVERTER INSTALLATION - TRINA TSM-300DD05A.08(II) I ENPHASE IQ6-60-2-US 1.3.5 PV EQUIPMENT GROUNDING 1.3.6 PV SYSTEM WIRING TO A ROOF -MOUNTED JUNCTION BOX 1.3.7 PV LOAD CENTERS (IF INCLUDED) 1.3.8 PV METERING/MONITORING (IF INCLUDED) 1.3.9 PV DISCONNECTS 1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.3.11 PV FINAL COMMISSIONING 1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE SCOPE OF WORK SYSTEM SIZE SOLAR STC: 26 x 300 = 7.800kW PTC: 26 x 270.6 = 7.036kW DC (26) TRINA SOLAR TSM-300DDO5A.08(II) (X26 MICROINVERTERS) ENPHASE IQ6-60-2-US ATTACHMENT TYPE: UNIRAC STANDOFF MSP UPGRADE: NO NEW PV SYSTEM: 7.800 k FORBES RESIDENCE 304 NE 99 ST MIAMI SHORES, FL, 33138 APN: 1132060135600 IECTOR ■ n o I n■ s'■ 651 W. GALENA PARK BLVD. STE. 101 PHONE (8011 990- 1 775 DRAPER, UTAH B4020 WWW.VECTORSE.COM Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure Is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. AERIAL PHOTO 01 NOT TO SCALE NE 99 ST PLAT MAP 02 NOT TO SCALE W w 'wi {os • 44: �5i$' ION p s' 03/29/2018 Engineer License - 74277 License Expiration - 2/28/2019 Certificate of authorization - COA 26626 VSE Project # U1869-1609-181 N S SHEET LIST TABLE SHEET NUMBER SHEET TITLE T-001 COVER PAGE G-001 NOTES A-101 SITE PLAN A-102 ELECTRICAL PLAN A-103 SOLAR ATTACHMENT PLAN E-601 LINE DIAGRAM E-602 DESIGN TABLES E-603 PLACARDS S-501 ASSEMBLY DETAILS R-001 RESOURCE DOCUMENT R-002 RESOURCE DOCUMENT R-003 RESOURCE DOCUMENT R-004 RESOURCE DOCUMENT R-005 RESOURCE DOCUMENT R-006 RESOURCE DOCUMENT PROJECT INFORMATION OWNER NAME: PHONE: JOHN FORBES PROJECT MANAGER NAME: JUAN ACOSTA PHONE: 7863548812 CONTRACTOR NAME: PHONE: PROSOLAR SYSTEMS LLC 8502223554 AUTHORITIES HAVING JURISDICTION BUILDING: MIAMI-DADE COUNTY ZONING: MIAMI-DADE COUNTY UTILITY: FPL DESIGN SPECIFICATIONS OCCUPANCY: II CONSTRUCTION: SINGLE-FAMILY ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 175 MPH APPLICABLE CODES & STANDARDS BUILDING: FBC 2017 FRC 2017 ELECTRICAL: NEC 2014 FIRE: FFPC 2017 p SYSTEMS CONTRACTOR PROSQLM SYSTEMS LLC • • • • • • • •:MOI : 8502221,5V.• .• • • AMS: 725WLAS OLAS BLVDrf • • • • • • LAUDERCALE, FL 3331: • • • • • • • • • • • • • • ■• • ;L%'i0.: CVcr04 ; •• MC. NO.: •• •• •• ••11..5.110,: • • UNAIRHORIZED QQF l • DROWING SET W OUTR�EN • • PERMISSION FROM CONTRACTOR IS IN* • •VIOURION OF U4.t P GJ-IT LAWS • AND WILL BE SUBJGCT TO8GIVIL DAMAGES AND PROSECUTIONS. • • • NEW PV SYSTEM: 7.800 kWp FORBES • RESIDENCE 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE:11" x 17" (ANSI B) COVER PAGE DATE: 3.28.2018 DESIGN BY: A.G. CHECKED BY: M.M. REVISIONS T-001.00 A • B ■ C ■ D t• E ■ F ■ G • H (SHEET 1) A • B ■ C • D ■ E• F ■ G ■ H 2.1.1 SITE NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. "2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.2.1 EQUIPMENT LOCATIONS: 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE -COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF -PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.4.1 WIRING & CONDUIT NOTES: 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING. 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 2.4.4 VOLTAGE DROP LIMITED TO 1.5%. 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. 4.5.1 GROUNDING NOTES: 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTORERS' INSTRUCTIONS. 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 2.5.10 GROUND -FAULT DETECTION SHALL COMPLY WITH NEC 690.5 IN GENERAL AND NEC 690.5 (A)(1) SPECIFICALLY. 2.6.1 DISCONNECTION AND OVER -CURRENT PROTECTION NOTES: 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS). 2.6.3` _ _ DISCONNECTS_ TO_BE_ACCESSIBLE TO QUALIFIED. UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 2.6.4 RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS 530V AND 5240VA [NEC 690.12]. LOCATION OF LABEL ACCORDING TO AHJ. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC -FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 2.7.1 INTERCONNECTION NOTES: 2.7.2 LOAD -SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 690.64 (B)] 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)]. 2.7.4 WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(D)(2)(3)]. 2.7.5 AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (D)(2)(3)(C). 2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (D)(2)(1) 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8 BACKFEEDING BREAKER FOR UTILITY -INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (D)(5)]. ■ prosoary SYSTMS CONTRACTOR PROSO104R6V STEMS LLC • • • +IOIE: 850222:5 • .• • • • ADDRESS: 725'Vt M OLAS BLVTPDRT • • LAUDERDALE, FL 333'Q • . • .... ..•• r • •• LNe.�10.: CVQ 57028 •• • •• FIIE. NO.: • • • • • • • • ELE,NO,: • • . • • UNAIIFHORIZED4USE OF' HIS • DReWING SET INPUT IJ EGRITTEN • • oERMISSION FROM CONTRACTOR IS IN, • • VIOLATION OF U.SUCOPYPIGHT LAWS • AND WILL BE SLItiGT•t46IIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.800 kWp FORBES • RESIDENCE 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11"x 17" (ANSI B) NOTES DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M. REVISIONS G-001.00 A • B C ■ D • E ■ ■ (SHEET 2) A • ■ C ■ D ■ E ■ F ■ G • H NE 99 ST (E) METER (E) ATS (N) AC DISCONNECT GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ------- PROPERTY LINE SITE PLAN 01 1/16" =1'-0" 0 8' 16' W N S E prosolar SYSTEMS CONTRACTOR PROSOVIR•SY! MS LLC • ▪ •PJ10N 8502223 • • , • • •AURESS: 725 V0 FA OLAS BLVD FQI • • • LAUDERD/LE, FL 33312: • .•.. •.•. • • •• .•.•• •••• ▪ • • Ve 11).: CVC 51928• ; A ■ B ■ C • D ■ E ■ ■ • • • HIC'NO.: • UNAU114ORIZED ltFa jkr. • DRAWING SET WI ITTEN • • PERMISSION FROM CONTRACTOR IS IN • OIOLAPON OF U.5♦Ct Y IGFjT LAWS • AND WILL BE SUBJEGT•TO CIVIL DAMAGES AND PROSECUTIONS. • •• •• .•• • • NEW PV SYSTEM: 7.800 kWp FORBES RESIDENCE 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11" x 17" (ANSI B) SITE PLAN DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M REVISIONS A-101.00 (SHEET 3) A ■ C • D ■ E ■ F • G • H 3'-0" FIRE ACCESS PATH ARRAY 1 - 4.200 kW [x14] (N) MODULES TILT: 30 DEGREES ROOF PITCH: 7:12 AZIMUTH: 270 DEGREES 3'-0" FIRE ACCESS PATH 3'-0" FIRE ACCESS PATH ARRAY 2- 2.100 kW [x7] (N) MODULES TILT: 30 DEGREES ROOF PITCH: 7:12 AZIMUTH: 90 DEGREES 3'-0" FIRE ACCESS PATH (N) ROOFTOP COMBINER BOX 3'-0" FIRE ACCESS PATH EXTERIOR PV EQUIPMENT (E) METER (E) ATS (N) AC DISCONNECT 0 //"\\ 0 0 0 0 0 0 0 0 0 0 0 0 0 • 4 0 0 0 0 0 0 0 0 0 0 0 0 • INTERIOR PV EQUIPMENT (N) TESLA GATEWAY (N) LOADS PANEL (MAIN ELECTRICAL PANEL) (N) GENERATION PANEL (N) AC DISCONNECT (N)(2) TESLA POWERWALL ELECTRICAL PLAN 01 ARRAY 3-1.500 kW [x5] (N) MODULES TILT: 30 DEGREES ROOF PITCH: 7:12 AZIMUTH: 180 DEGREES 1'-8" FIRE ACCESS PATH 3132" =1' 5'-4" 10'-8" W N S E GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE 3'-0" FIRE ACCESS PATH 1'-8" FIRE ACCESS PATH 0 0 MODULE STRINGING MODULE STRINGING / FIRE CLEARANCE Q P.v�cENSFR`rt�y�i • No 59727 '1 ' * : r �.� STAT -OF �ii'n�.\tos,'cLOR10P' . %'o \ /IIIIIIII� NOTE PER FL. STATUE 377.705 (REVISED 7/1/2017). I DEAN P. LEVORSEN, PE# 59727 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. ELECTRICAL REVIEW /,I-l'/Z-/e APPROVE DATE L 39.1" H -I MODULE: TRINA SOLAR TSM-300DDO5A.08(II) 300 WATTS ■ prosolar CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 ADDRESS: 725 4N11 6IAAS BLVD FORT • • LAUDtFtA2E FL 33312 • •• • •••• • • • •.•• In • •L1C. AD.: CVC 57 02E • ••E!.NO.: • • • • • • :l11,414HORIZED ySt OF•THQ • • DRAWING SET WITI CAJT WRITTEN • RMISSION FROM CONTRACTOR IS IN • • dLION OF U.S. COA(RIGHT LAWS • AND WILL BE SUBJECT TODCIVIL • DAWAGES AND PiteSt UTIONS. •'NEW PV Se.STPM: 7.800 kW15 • • • • • • •• • • • FORBES E. RESIDENCE 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11" x 17" (ANSI B) ELECTRICAL PLAN DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M REVISIONS A-102.00 • A B ■ C ■ D • E ■ F ■ ■ (SHEET 4) A • B C ■ D ■ E • F ■ G • H ROOF MATERIAL IS CLAY S-TILE 16'-4" 22'-10" I -- —• - 1 1 1 I 1 1 I 1 I 1 J 1 1 1 1 1 1 I I I I 1 b I 9 1 1 1 1 9 1 1 1 13'-0" SOLAR ATTACHMENT PLAN 01 3/32" = 1' 0 5'-4" 10'-8" W N S E VECTOR m n 0 I n■ p R e 651 W. GALENA PARE BLVD. STE. 101 PHONE (807) 990-7775 DRAPER, UTAH 84020 WWW.VECTORSE.COM Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. 65" L GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ROOF TRUSSES 14, 277 '%*14, • •Q: LU i• i i IS'minto 03/29/2018 Engineer License - 74277 License Expiration - 2/28/2019 Certificate of authorization - COA 26626 VSE Project # U1869-1609-181 39.1" MODULE: TRINA SOLAR TSM-300DDO5A.08(II) 300 WATTS A • B ■ C ■ D ■ E ■ ■ prosoiar SYST CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 • ADQRESS: 7294 NS•OtAS BLVR NIL • • • • • ; LAUDE ,J.. ,FL33312 •• •••• • • ' • LIB NO.: CVC 5708 • •TIICrNO,: •••••• • • ILO ELE. NO,: • • • • • • • .•.._• • • •__-_ • UNAYTHORIZECYUSE l ' THIS • • LfCAWING SET WITh UTIVRITTEN • • • B lSSION FROM CQNTRACTOR IS IN • VIOLATION OF U.S. COPYRIGHT LAWS • ANCRNILL BE S IiE T TT11�Yr�1,, IVIL • DgpIAGES AND ROsE�UTIONS. • - • •NEW PV SYSI- IVM: 7.80• 0 kVllp ■ • •• FORBES RESIDENCE- 304 NE 99 ST • MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11" x 17" (ANSI B) SOLAR ATTACHMENT PLAN DATE: 3.28.2018 DESIGN BY: A.G. CHECKED BY: M.M REVISIONS A-103.00 (SHEET 5) A • B • C • D • E • F • G ■ H (N) AC DISCONNECT 240VAC, 1-PH, 3W 200A, FUSED AT 200A NEMA 3R (E) UTILITY METER 03 03 •(E)ATSJ (E) GENERATOR t SIG Nip • L _ , Jt 0 (4) [24-16]AWG THWN-2 02 (N) POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R c)c) 2® TOO24 `1 G EnTO lO '• _ CT LEADS BY TESLA - SEE INSTALLATION MANUAL I FOR MORE INFORMATION L_-T TO r • G L L (N) BACKUP GATEWAY TESLA P/N 1118431-XX-X 200A MAX, NEMA 3R NOTE PER FL, STATUE 377.705 (REVISED 7/1/2017), I DEAN P. LEVORSEN, PE# 59727 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. I ELECTRICAL REVIEW APPROVE ,DATE _ Ii (N) AC DISCONNECT 240VAC, 1-PH, 3W 200A, FUSED AT 200A NEMA 3R AC DISCONNECT WITHIN 15' OF THE METER BASE _ , , _ 03 1 d 200A CTRL CTRL TO 02 - 30A 30A CTRL 03 (N) GENERATION PANEL 240VAC, 1-PH, 3W 200A BUS, NEMA 3R 35A (4) [24-16]AWG THWN-2 02 (N) POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R Q-12-17-240-40 ENPHASE ENGAGE (TM) TRUNK CABLE FOR 60 CELLS MODULE (N) MICROINVERTER IQ6-60-2-US 240 VA, 240VAC NEMA 250 (N) ENPHASE ENVOY COMMUNICATIONS GATEWAY 01 dN uQ UO Q AGGREGATOR Q-BA-3-1P-60 7.8 KW, 240VAC NEMA 3 03 r(N) LOADS PANEL (MAIN ELECTRICAL PANEL) 240VAC, 1-PH, 3W 200A'BUS" - NEMA 3R I. • • I 200A CIMID 20A (N) PV MODULE STRINGS TSM-300DDO5A.08(II) 7800 W, 40VDC 2 STRINGS OF 13 MODULES ::::::::;3 *AO1i 1fr STATE i .•3 Fsi=4OR1OF%'0\ soNAL ?\\ /I/IMM 5D D n „ c iii••�v \\� \� • �� c1pV,p Q�ip.��N\oC5EN7S7* ■ prosolatSYSTEM CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 I... : • UDEB4A • ▪ D4RESS: LALDE FL33312 4FAgr � • • • • • • • • • • laic. NO.: CVC 57028 •��HIC•.'NO ,• • • • • • • ELE. NO.: • • • • • UNAI/FHORIZEDUSE 00 THIS • • IMWING SET WITAQIJT OVRITTEN • • •FISSION FROM CONTRACTOR IS IN • VIOLATION OF U.S. COPYRIGHT LAWS • ANDOVILL BE SU:CiiTJQCVIL • DAMAGES AND PROSECUTIONS. • • • • • •• NEW PV SZ /NI: 7.800 kWp • • • FORBES • 'RESIDENCE ■ 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11" x 17' (ANSI B) LINE DIAGRAM DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M. REVISIONS E-601.00 A • B ■ C ■ D s E • • (SHEET 6) A • ■ C ■ D E r F ■ G ■ H SYSTEM SUMMARY BRANCH #1 BRANCH #2 INVERTERS PER BRANCH 13 13 MAX AC CURRENT 12.48A 12.48A MAX AC OUTPUT POWER 3,120W 3,120W ARRAY STC POWER 7,800W ARRAY PTC POWER 7,036W MAX AC CURRENT 24.96A MAX AC POWER 6,240W DERATED (CEC) AC POWER 6,240W DESIGN TEMPERATURES ASHRAE EXTREME LOW 1.9°C (35.4°F), SOURCE: MIAMI (25.82°;-80.3°) ASHRAE 2% HIGH 33.1°C (91.6°F), SOURCE: MIAMI (25.82°;-80.3°) MODULES REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING P1-26 26 TRINA SOLAR TSM-300DD05A.08(II) 300W 270.6W 9.77A 9.19A 39.8V 32.6V -0.115V/°C (-0.29%/°C) 20A INVERTERS REF. QTY, MAKE AND MODEL AC VOLTAGE GROUND OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 11-26 26 ENPHASE IQ6-60-2-US 240V FLOATING 20A 240W 0 96A 15A 48V 97.0% DISCONNECTS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1,2 2 FUSED AC DISCONNECT 200A 240VAC OCPDS REF. QTY. RATED CURRENT MAX VOLTAGE CB1 1 35A 240VAC CB2,3 2 30A 240VAC CB4 1 5A 240VAC F1-4 4 200A 240VAC F5-10 6 20A 240VAC CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT -CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 01 1 8 AWG THWN-2, COPPER 1.0"DIA EMT 2 35A 8 AWG THWN-2, COPPER 0.71 (55.1°C) 1 24.96A 31.2A 55A 39.05A 75°C 50A 2 1 10 AWG THWN-2, COPPER 0.5" DIA EMT 3 30A 10 AWG THWN-2, COPPER 0.96 (33.1°C) 1 - 30A 40A 38.4A 75°C 35A 3 1 3/0 AWG THWN-2, COPPER 2" DIA EMT 3 200A 3/0 AWG THWN-2, COPPER 0.96 (33.1 °C) 1 - 200A 225A 216A 75°C 200A proso SYSTEMS CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 •••• . ADDRESS: 725 01/4.4SQLAS BLVD FQf;T... •..• LAUDEPP tt.FL33312 .• • • •••• ▪ • 1.1C,N0.: CVC 5j4$ . • • ••111C,NO.: •....• • • ••:��1� • • ----• 1JNAUlHORIZED ll6E OPfHIS • • DRAWING SET WITIVIT VO2RTEN • • • tPIAMISSION FROM CONTRACTOR IS IN • • VIOLA?ION OF U.S. COPYRIGHT LAWS • • AND ALL BE SUCF4cilaq/IL • DAMAGES AND PfiOSECUTIONS. • • • • • --•••• •• • •• • • • ELECTRICAL R W 74-jix-ie 4111,11 APPROVEer,airrei DATE NOTE PER FL. STATUE 377.705 (REVISED 7/1/2017), I DEAN P. LEVORSEN, PE# 59727 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL. COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. \\0111111111//, g „":/ 4ro LEI/04V*, * • No 59727 ✓ ?� INN STAT ✓/J.JJJ 110 00. ti ■ NEW PV SYSTEM: 7.800 kWp FORBES -RESIDENCE- 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11"x 17' (ANSI B) DESIGN TABLES DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M. REVISIONS E-602.00 A • B ■ C ■ D • E • F • G H (SHEET 7) A ■ D E F ■ G . H ! WARNING! • 0 ' • ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED0 "GROUNDED CONDUCTORS MAYBE UNGROUNDED AND ENE GRED LABEL 1 AT EACH INVERTER [NEC 690.5] ARNING'1! DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM I WARNING LECTR(6 SHOCK HAZARD lj DO NOT; TOUCH TERMINALS. LEER INALS OtThOTHLINE AND LOAD SIDES MAY BE ENERGIZEDIN THE.OPEN POSITION. LABEL 2 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.17] PHOTOVOLTAIC 0 AC DISCONNECT OPERATING CURRENT: 24.96 A AC OPERATING VOLTAGE: 240 V AC 0 LABEL 4 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS - [NEC 690.54] 0 ! CAUTION'! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED 0 LABEL 5 LABEL 6 AT POINT OF INTERCONNECTION; LABEL, SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY PHOTOVOLTAIC SYSTEM (NEC 705.12(D)(4)] LABEL 10 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED 0 PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED SOUTH SIDE OF THE HOUSE PLAQUE 0 INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED LABEL 7 AT UTILITY METER [NEC 690.56(B)] 0 PHOTOVOLTAIC 0 AC DISCONNECT LABEL 11 AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] !WARNING I , INVERTER OUTPUT, CONNECTION Q ' DO NOT RELOCATETHIS OVERCURRENT DEVICE LABEL 12 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE [NEC 705.12(D)(7)] LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISD 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. "DANGER" WILL HAVE RED BACKGROUND; "WARNING" WILL HAVE ORANGE BACKGROUND; "CAUTION" WILL HAVE YELLOW BACKGROUND. [ANSI Z535] DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(H)] ICTION. 0 !CAUTION! 0 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: W N S E FRONT BACK MAIN DISTRIBUTION UTILITY DISCONNECT 0 0 IELECTRICAL REVIEW 3771._20 APPROVED W-DATE i No 597 - '- . l STATE /� DNAL EN \\\ 111111 NOTE PER FL. STATUE 377.705 (REVISED 7/1/2017), I DEAN P. LEVORSEN. PE# 59727 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. prosoF:t SYSTEMS CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 • ADURESS:725'VILI.ASOCAS BLVD,F4 •. . • • • LAUDEQDAI6, FL 33312 •• •• • • • • • VG. NO.: CVC Vg43• •••[jlg.'NO.: • • • • • • •••,L,f.NO.: • • • • • UNAIlfHORIZEDILE 0, THIS DRAWING SET WIT JT FFITTEN • • • • REIIMISSION FROM CONTRACTOR IS IN • AO ION OF U . COPY$$IGHT LAWS • AND ILL BE SUJjGTJIjfiVIL • DAMAGES AND PIROSECUTIONS. • • • • • •• • •• • • • NEW PV SYSTEM: 7.800 kWp FORBES • RESIDENCE A B . C ■ D . E ■ F ■ ■ 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE:11" x 1T (ANSI B) PLACARDS DATE: 3.28.2018 DESIGN BY: A.G. ■ CHECKED BY: M.M. REVISIONS E-603.00 (SHEET 8) A B ■ C ■ D ■ E ■ F ■ G ■ H D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE Ii mmmmmmmmmmmmommammoo AA rim�����WW1 10101010 !RPM mown wok 0101010 IMAM 0101010 NOW FIFIRA RIITIN111111A7171�111111171MA0111A 110101010101010101010100101010101010101010101010101 D3 RACKING DETAIL (TOP) NOT TO SCALE D4 DETAIL (TRANSVERSE NOT TO SCALE iUMWO u GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS D2 RACKING DETAIL (LONGITUDINAL) 0 SHEET KEYNOTES NOT TO SCALE 400 U 4, ti.,,...N/ 44, RACKING i THIS EDGE TOWARDS ROOF RIDG D6 DETAIL (ISOMETRIC) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE STRUCTURAL REVI APPROVED DATE!w \IECTC:IR n 0 I n■ E R• 1. ROOF MATERIAL: CLAY S-TILE 2. ROOF STRUCTURE: TRUSS 3. ATTACHMENT TYPE: UNIRAC STANDOFF 4. MODULE MANUFACTURER: TRINA SOLAR 5. MODULE MODEL: TSM-300DDO5A.08(II) 6. MODULE LENGTH: 65" 7. MODULE WIDTH: 39.1" 8. MODULE WEIGHT: 41 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: NO FIRE CODE ENFORCED 11. TRUSS SPACING: 24 IN. O.C. 12. TRUSS SIZE: 2X4 NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 3 IN. 15. TOTAL # OF ATTACHMENTS: 54 16 TOTAL AREA: 458.88 SQ. FT. 17. TOTAL WEIGHT: 1360.95 LBS. 18. WEIGHT PER ATTACHMENT: 25.2 LBS. 19. DISTRIBUTED LOAD: 2.97 PSF. 20. MAX. HORIZONTAL STANDOFF: 48 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 33 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER (OR EQUIV.): UNIRAC 24. RAIL MODEL (OR EQUIVALENT): STANDARD 25. RAIL WEIGHT: 0.728 PLF. 26. MAX. TRUSS SPAN: 9 FT. 27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. )) 651 W. GALENA PARK BLVD. STE. 101 PHONE (8011 990-7775 DRAPER, UTAH 84020 WWW.VECTORSE.COM Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. • 4,10 277 ir;; • • • w •... ST AT tr 411. •i•FiSS,1 O N A1 Ws 03/29/2018 Engineer License - 74277 License Expiration - 2/28/2019 Certificate of authorization - COA 26626 VSE Project # U1869-1609-181 prosol 1 SYSTEMS CONTRACTOR PROSOLAR SYSTEMS LLC PHONE: 8502223554 •••• . ADDRESS: 725I DLAS BLVD Fat;... • ..• • LAUDER 4,FL33312 .• • • ••_ • • • • • ▪ • �I�•r0.: CVC 57�2�8• '•�I�C .•••• • S IAUTRORIZED USE OF RiIS• • • D141MING SET WITHdt WRITTEN • • RERMISFION FROM CONTiRACTOR IS IN • VIStAISDN OF U.S. COPYRIQHT LAWS • AND WILL BE SUB.L,TJQ • DAMAGES AND PR.SECUTIONS. • • • • • • • • • • NEW PV SYSTEM: 7.800 kWp FORBES RESIDENCE -- 304 NE 99 ST MIAMI SHORES, FL 33138 APN: 1132060135600 DESIGNER SIGNATURE PAPER SIZE: 11" x 17" (ANSI B) ASSEMBLY DETAILS DATE: 3.28.2018 DESIGN BY: A.G. CHECKED BY: M.M. REVISIONS S-501.00 A ■ B ■ C D ■ E ■ • ■ (SHEET 9)