Loading...
PL-18-1052Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address iermi Permit NO. PL-4-18-1052 Permit Type: Plumbing - Residential Work Classification: Gas Permit Status: APPROVED Issue Date: 5/1512018 Expiration: 11/11/2018 Parcel Number Applicant 1053 NE 95 Street Miami Shores, FL 1132060143600 Block: Lot: SEAN SHEA Owner Information Address Phone Cell SEAN SHEA 1053 NE 95 ST MIAMI FL 33138-2547 Contractor(s) FOREVER GAS CORP Phone (305)298-0193 Cell Phone Valuation: Total Sq Feet: $ 1,395.00 0 Type of Work: INSTALLATION OF POLY PIPE TO FIRE A Type of Piping: Additional Info: Bond Return : Classification: Residential, Scanning: 1 Fees Due CCF DBPR Fee •DCA Fee Education Surcharge Permit Fee Scanning Fee r Technology Fee Total: Amount $1.20 $2.25 $2.00 $0.40 $150.00 $3.00 $1.60 $160.45 Pay Date Pay Type Invoice # PL-4-18-67240 04/20/2018 Credit Card 05/15/2018 Check #: 1730 Amt Paid Amt Due $ 50.00 $ 110.45 $ 110.45 $0.00 Available Inspections: Inspection Type: Final Press Test Review Plumbing ti In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWN constr FID zonin all he foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating Sre, I a thorize the above -named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent May 15, 2018 Date Building Department Copy May 15, 2018 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING LUMBING ❑ MECHANICAL Eli PUBLIC WORKS JOB ADDRESS: FBC 20 I R- Master Permit No (Q raig) Sub Permit No1L. (�j ` 1 OEZ ❑ REVISION ❑ EXTENSION /o 5-3 NC 9s- 1- City: Miami Shores /� `,, // County: Folio/Parcel#: c� 1lc 3 2-o -'"(/f' b 00 Occupancy Type: F Load: CHANGE OF ❑ CANCELLATION CONTRACTOR Miami Dade Zip: Is the Building Historically Designated: Yes Construction Type: C/J Flood Zone: BFE: FFE: ❑RENEWAL ❑ SHOP DRAWINGS NO V OWNER: Name (Fee Simple Titleholder): cS€CL47 cS -�f� Phone#: 7J Address: /c c 3 46 5/— City: lilta JA es' State: kl Email:®n(/1G/�� tv.0 S(/ f%f�`• ) Tenant/Lessee Name: Phone#: (s? 3 7792- Zip: J 0/ 3 O fr Phone#: ram% 1 0) 9? Zip: 3:3dlS` Phone#: � 7 V7 State Certification or Registration #: Certificate of Competency #:6 T 4 0 Address: I' / / / A) LI CONTRACTOR: Company Name: 1 i �2 Pt' !L /OS 1 ) City: / Jt (c,/e �� State: / G , Qualifier Name: 2 z_ Li/G► DESIGNER: Architect/Engineer: * It) 44. Phone#: Address: City: State: Value of Work for this Permit: $ `(2 S • 00 Type of Work: ❑ Addition ❑ Alteration Description of Work: L h s '// -/ fiy 44) k �,1,�otiCL l rL Specify color of color tluu"tile ;: 1s Submittal Fee $ a.�'Y"Permit Fee $ Zip: Square/Linear Footage of Work: New /0- Scanning Fee $ Radon Fee $ Q Technology Fee $ Training/Education Fee $ 11°1 I PO Repair/Replace ❑ Demolition 1� L° # . • :}Y�.r�....t Itr ra+a.:n.i+,'. tx ,��; {ro .i ;XI• rJIST4Je: 1 CCF $ CO/CC $ DBPR $ . �� Notary $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ I ( 0 • l (Revised02/24/2014) FF1 f . Bonding Company's Name (if applicable) .,, 1`41+ Bonding Company s Address City - State Zip Morttage'Lender's Name (if applicable) Mortgage Lender's Address City • State . Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I `understand that a, separate permit 'must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS,'ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is -accurate and that all work will be done in compliance with all • applicable laws regulating construction and zoning. "WARNING TO OWNER: Yb11I2, FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE 'FOR IMPROVEMENTS TO YOUR PROPERTY. IF 'YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING � YOUR NOTICE OF COMMENCEt;MENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated, value exceeding $2500, tile' dp'p' licant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occuseven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved a d : reinspection fee will be charged. • Signature Signature U 4 OWNER or AGENT _ '.� CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrume t was acknowledged befor me this � day of f"' • 1_/ 720 �:O ��✓ -C by �day � .% - -- ,20— 1--by t :.1 . "e.Ch — h ''"`.- , who is personally known to G,Sev 1/-6` ,Y).—C e.;2-, who is personally known to mme�or who has produced as , me.., or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: •`OiR' ****************** APPROVED BY • ra QAn4-breswv AI.EJANORA GRIGOREIlCU * MY COMMISSION I FF 143529 • EXPIRES: July 21, 2018 Bondedlbru I101Nonry Senws identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Plans Examiner dra Olcisofej(JA Y pad • ;`� ALEJANORA GRIGOF9CU * "ISSION t FF 143529 txPIRES: July 21:2018) ovnaR•l� amid o � • .' Zoning (Revised02/24/2014) Structural Review Clerk sk)->v ELECTRICAL REVIEW V le APPROVED _DATE Notes: Riser Diagram Sean Shea Residence • All conduit 2" EMT/PVC 1053 NE 95 St. Miami Shores, FL 33138 with 2o wire • Conduit from ATS to generator is 2" with #2 wire • All above ground conduit strapped to wall with Unistrut • Generator line buried from house wall to generator 36" deep • Generator riser strapped with Unistrut to pad • 200 AMP Service / 200 AMP Automatic Transfer Switch 38kw generator, 175 AMP Breaker Automatic Transfer Switch with Integrated Service Disconnect 2" Conduit w/ 2o wire buried 36" deep 1" Conduit w/ 6 onductor low voltage wire • • Interior House Panel #1 6" Gutter • . Interior House Panel #2 Interior House Panel #3 • •OOOOOO . . •. •' "'Low and' High' voltage conduit are • ..•. str•aigb•t thr•pugb gutter. . •. . .... .. •.. .. •.. .. •. • . . . • • • .... . 1 Sean Shea 1053 NE 95 St. Miami Shores, Fl. 33138 RLV CORP 1401 NE 101 St Miami Shores, M. 33138 (305) 7904899 Genemc Dealer # 1020948 Dear Sean; RLV CORP is pleased to provide the following proposal: Aescrintion of Work: RLV CORP will provide for a new 38 kw Generac Protector QS Series Model RG038, Single Phase, 120/240V, Natural Gas fired, 1800 RPM, aluminum cabinet generator with matching whole house NEMA 3R 200 AMP Single Phase Automatic Transfer Switch (ATS) with Service Disconnect. telkiInstallation includes: Installation of generator on North side of property. RLV CORP will frame and pour a 24" tall concrete slab or at required height meeting interior floor level, provide for all gas and electrical (low and high voltage) labor and materials between gas/electric sources to generator, installation of ATS, 26R battery, system registration, test and turn up, doamientation presentation, customer overview and acceptance. • • • • •. Warranty: RLV CORP warrants generator, ATS, labor, workmanship and materials fo; • •�ygts.'A"o�Q.yfar • annual service plan is included with this contract. This plan includes 2 visits per year. . RLV CORP will coordinate and supervise all phases of this pioject from design, installation. testing,: • • . • • • • • permitting and user acceptance/training. . . .. .. All permitting fees charged by local municipalities are pass -through costs paid by home nv r • . Material Description and Associated Labor: • . Guardian Series Model RG038 (please see attached brochure for more information) • • • 200 AMP Single Phase, Automatic Transfer Switch, with Service Disconnect • Group 26R Battery Poured Concrete Slab (24" high, length and width to be 4" greater on all sides of generator footprint) Gas line and electrical connections, material & labor .. • . . . ..• . Sub Total 6% Tax: TOTAL: $21,750. $1,305. $23,055. Installation Interval: Estimated installation time will take 30-60 days barring any unforeseen events including material shortage, permitting delays, access limitations, acts of God, and / or failure to scheduled payments. AA 6O% ce deposit ($13,833) is required to start, with 40% ($9,2222) due upon system 1 �... up . , customer aca We look forward to delivering a quality installation for you. ACCEPTED REED: S� ea — Robert B. Vickers — President RLV Corp. Date () )2- Date hl2y/ /7 • . . . • vae-cg__ 6q345 oicvD ///2-7 //7 Quote valid for 30 days Page 1 of 1 11/22/2017 gC- A fos! SZJLeL hoar • •• ••• • • • • • • • • • • •• • • • •• • • • •• • • • •• • • • • • ••. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• • • • • • • • • • • • All Quality Electrical Service Inc. 14750 S. River Dr. Miami, Fl. 33167 Qualifier: Samuel Lightbourne CC#05E000478 Job Name: Shea Residence 1053 Ne 95 St Miami Shores, Fl 33138 Electrical Panel "A" Schedule Type Service Voltage Mounting Poles Square D 20, 3 wire 120/240V Flush 20 Load Wire Breaker Equipment 4500 10 25A/2P Water Heater 5768 14 1500 12 14 14 14 1840 12 15A/1P 20A/1P 15A/1P 15A/1P 15A/1P 20A/2P Family Room Rec. Bathroom General Lighting General Lighting General Lighting Pool Pump Circuits 1 3 5 7 9 11 13 15 17 Main Bus Nuetral Mains Location A.I.C. 200 AMPS FULL M.L.O Laundry 10,000A Circuits Equipment Breaker Wire Load 2 4 6 8 10 12 14 16 18 Small Appli. Small Appli. A/C #1 Comp Bath/Smk. Det Dining Room Mstr. Bedroom Dishwasher Disposal 20A/1P 20A/1P 40A/2P 15A/1P 15A/1P 15A/1P 20A/1P 20A/1P 12 12 6 1500 1500 6500 14 14 14 12 1500 12 1200 TOTAL WATTS LESS A/C UNITS - 19308 W First 10000A at 100% = 10000W Remainder at 40% = 3723W A/C Units Load = 6500w TOTAL PANEL LOAD = 20223 w / 240V = 84 AMPS •• ••• • • • • • •• • • • • • • • •• Y•• •• • • • •• • ••• • • • • • • • • • • •• • • • • • • Y J • • • • • ••• • • • • • • • • • • • • • •• •• ••• • • ••• • • • • • • • ••• • • • OOOOO • • • • • • • • • • ••• • • • • • • • ••• • • • • • • • • • • • • •• •• • ••• • • All Quality Electrical Service Inc. 14750 S. River Dr. Miami, Fl. 33167 Qualifier: Samuel Lightbourne CC#05E000478 Job Name: Shea Residence 1053 Ne 95 St Miami Shores, Fl 33138 Electrical Panel "A" Schedule Type Service Voltage Mounting Poles Square D 20, 3 wire 120/240V Flush 20 Load Wire Breaker Equipment 4500 10 25A/2P Water Heater 5768 14 1500 12 14 14 14 1840 12 15A/1P 20A/1P 15A/1P 15A/1P 15A/1P 20A/2P Family Room Rec. Bathroom General Lighting General Lighting General Lighting Pool Pump Circuits 1 3 5 7 9 11 13 15 17 Main Bus Nuetral Mains Location A.I.C. 200 AMPS FULL M.L.O Laundry 10,000A Circuits Equipment Breaker Wire Load 2 4 6 8 10 12 14 16 18 Small Appli. Small Appli. A/C #1 Comp Bath/Smk. Det Dining Room Mstr. Bedroom Dishwasher Disposal 20A/1P 20A/1P 40A/2P 15A/1P 15A/1P_ 15A/1P 20A/1P 20A/1P 12 12 6 1500. 1500 6500 14 14 14 12 1500 12 1200 TOTAL WATTS LESS A/C UNITS - 19308 W First 10000A at 100% = 10000W Remainder at 40% = 3723W A/C Units Load = 6500w TOTAL PANEL LOAD = 20223 w / 240V = 84 AMPS • .. ... . . . . • .. . . . . . •• . .. ... .. . • . .. • ... . ... . . • . . ., • . . . • . . . . . . • . . •. .• . . .. . •. • . . . . . . . . . • . •. .. . • • . • ... . . . . ... • . . •.. . . • . •. . . • . • .. • . . . • . . • . • . . • • .. . . . .. •• • .• ... .. Protector® QS Series INCLUDES: • Two Line LCD Multilingual Digital Evolution' Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. • True Power' Electrical Technology • • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed • Capability to be installed within 18" (457) mm of a building* *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. GENERAC® PROTECTOR® QS SERIES Standby Generators Liquid -Cooled Gaseous Engine • • •• • • • Standby Power Rating - • Model RG022 (Aluminurtj; i que)-. kW 60 Vile*: Model RG027 (AluminuNfZisque)..274 W 60:12••; Model RG032 (Aluminurra••Bisque): 32kW 60 -10►.• Model RG038 (Aluminum; •Bisque) •-•38 4 W 60 H • • Model RG048 (AluminuM -'Bisque) -'41kW 60 Tit • • • • • • QUID WY -•,.... SIlI llllII111IIII1tl1111W11 Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA • 1of11 FEATURES 0 INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA: 4 PROTOTYPE TESTED 4 SYSTEM TORSIONAL TESTED 4 NEMA MG1-22 EVALUATION 4 MOTOR STARTING ABILITY O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC® 07 y 0 Cr 0 0, 0 0 2of11 • • • • •• ••• • •• • • • •• 22 • 27 • 32 • 38 • 48 kW GENERAC® application & engineering data GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32, 38 & 48 kW) Stator Insulation Class H Telephone Intqfgrgrlie Factor (TIF) <50 'Alternator Output Leads 1-Phase • • 4 wire • • Alternator OCtptft Leads 3-Phast • • • 6 wire "oearings "• ` • Sealed Ball • • ' & ipling • • • • • • • Flexible Disc iv Frr.itation System • •• • • • • • Direct • • • • • • • JOLTAGE REMOTION • • • • • • • • • • • • •• • • Type •• • • Electronic ' gensing ` ` . • ` • Single Phase • 'Regulation • •• • • ••.• ±1% • GOVERNOFi SPECIFICATIONS Type Electronic Frequency Regulation lsochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271) ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model V-Type Cylinders 8 Displacement (Liters) 5.4 Bore (in/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge Crankcase Capacity (qVl) 4/3.8 (22, 27, 32 & 38 kW) or 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven Fan Speed (rpm) 1980-22&27kW 1500 32 & 38 kW 1954 - 48 kW Fan Diameter (in/mm) 18.1/459.7 (22 & 27 kW) or 22/558.8 (32, 38 & 48 kW) Fan Mode Pusher (22 & 27 kW) or Puller (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 - 14" Water Column NG Fuel Pressure 5 -14" Water Column 22 • 27 • 32 ` • 38 • 48 kW GENERAC® operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat Gas Amp Nat. Gas •GB.Size (Both) RG022 120/240 V, 10, 1.0 pf 22 92 22 • •92 •• • • • • • •100 • •' 120/208 V, 30, 0.8 pf 22 76 22 76 • : • • &0 120/240 V, 30, 0.8 pf 22 66 22 • •66o . • • • • - 80 • RG027 120/240 V, 10, 1.0 pf 27 ' 113 25 W.. • • .125 • • " 120/208 V, 30, 0.8 pf 27 94 25 • BZ • • • • • • 0u0 • • • 120/240 V, 30, 0.8 pf 27 81 25 •99••: .••••a0 ••' RG032 120/240 V, 10, 1.0 pf 32 133 32 •133 • • • • .150 • • 120/208 V, 30, 0.8 pf 32 111 32 �111. •• • 125 • 120/240 V, 30, 0.8 pf 32 96 32 • 96 . • • • • •11!)0• 277/480 V, 30, 0.8 pf 32 48 32 •4P. • . • • • •60 . • • RG038 120/240 V, 10, 1.0 pf 38 158 38 158 • • • • •175 120/208 V, 30, 0.8 pf 38 132 38 132 150 120/240 V, 30, 0.8 pf 38 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 RG048 120/240 V, 10, 1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 120/240 V, 30, 0.8 pf 48 144 48 144 150 277/480 V, 30, 0.8 pf 48 72 48 72 80 SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf 15% 30% RG022 120/240 V, 10 55 135 120/208 V, 30 40 92 120/240 V, 30 35 80 RG027 120/240 V, 10 62 170 120/208 V, 30 70 120 120/240 V, 30 61 103 RG032 120/240 V, 10 75 180 120/208 V, 30 87 210 120/240 V, 30 75 182 277/480 V, 30 36 87 RG038 120/240 V, 10 75 180 120/208 V, 30 87 210 120/240 V, 30 75 182 277/480 V, 30 36 87 RG048 120/240 V, 10 85 195 120/208 V, 30 90 218 120/240 V, 30 78 189 277/480 V, 30 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. ENGINE FUEL CONSUMPTION Natural Gas Propane (ft3/hr) (m3/hr) . (gal/hr) (I/hr) (113/hr) RG022 Exercise cycle 34 1.0 0.4 1.4 13 25% of rated load 142 4.0 1.4 8.2 52.5 50% of rated load 207 5.9 2.1 7.8 78.6 75% of rated load 274.6 7.8 2.9 10.9 104 100% of rated load 342 9.7 3.6 13.7 129.7 RG027 Exercise cycle 40 1.1 0.4 1.7 15 25% of rated load 155 4.4 1.6 , 6.2 58.7 50% of rated load 233 6.6 2.6 9.5 90.4 75% of rated load 314 8.9 3.3 12.7 121 100% of rated load 396 11.2 4.1 15.7 149 RG032 Exercise cycle 44 1.3 0.5 2 19 25% of rated load 138.8 3.9 1.5 5.7 53 50% of rated load 218.8 6.2 2.6 10.2 94.9 75% of rated load 301 8.5 3.7 14.2 132 100% of rated load 380.6 10.8 4.6 17.6 166 RG038 Exercise cycle 44 1.3 0.5 2 19 25% of rated load 156 4.4 1.7 • 6.4 60 50% of rated load 260 7.4 3 11.4 107.8 75% of rated load 361.7 10.2 4.2 16.2 153 100% of rated load 444 12.6 5.4 ' 20.4 192 RG048 Exercise cycle 63 2.0 0.9 3.3 31 25% of rated load 270.6 7.7 3.1 11.7 110.9 50% of rated load 425 12.0 5.0 19 151 75% of rated load 557.7 15.8 6.8 25.8 244.5 100% of rated load 638 18.5 8.7 33 312 •• • • •• •• • •• y 2- L C rD 0 ri 3 of 11 ••• • • • ••• • ••. • STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with IS0-3046-1. Design and specifications are subject to change without notice. :• •. •• 1of11 • • •• • •• 22, 27 . 32 . 38 . 48 kW y. GENERAL® 'I operating data ENGINE COOLING • • • • • • 22 kW 27 kW 32 & 38 kW 48 kW S. ... • • Air flow (inl4 ai‘igcluding alter:atd(' Fil tombustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 •%tem coolantcap.aty (gal/litir.). • • • 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 welt rejection td'coolant (BTU Arm per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2 Maximum operatien a1 temperature on radiator (°C/°F) 60/ 50 Maximum am6i8rfjtsmperature4T.CEt• • 50/140 • • COMBUSTIOZi REQUIREMVMEN.S. • • • • • Flow at rated Powar.(Am/cmm)r • • • • • • • SOUND E{VII$SRI,NS • • 68/1.9 68/1.9 106/3 163/4.6 Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 61 61 58 63 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 70 70 64 68 `Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (clnVcmm) 165/4.7 180/5.1 300/8.5 414/11.7 Exhaust temperature at muffler outlet (V°F) 482/900 538/1000 579/1075 552/1025 ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22, 27 & 48 kW) 1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (32 & 38 kW) 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation. Mode Switch: Auto Automatic Start on Utility failure. 7 day exerciser Off Stops unit. Power is removed. Control and charger still operate. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Standard Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up 5 sec Engine Cool -Down 1 min Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger ' Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard, 72 Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Failure to Transfer Protection Standard Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Protection Standard Internal Fault Protection Standard Common External Fault Capability Standard Governor Failure Protection Standard Protector® QS Series 167 [6.6] RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) 535 [21.1] 2.5' O.D. EXHAUST OUTLET REMOVE COVE FOR ACCESS TO RADIATOR FILL CAP RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES TOP VIEW 768 [30.2] —� CENTER OF GRAVITY SEE NOTE 5 =ATTERY 12V, GRP 26 NEGATIVE GROUND P/N: 077483 EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE Y WOW."' A FUEL LINE CONNECTIO DT CCLAAI C rM IDI wra 50 2.0] 1000 f39.41 LEFT SIDE VIEW LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 7 AND CENTER OF GRAVITY DIMENSIONS SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIOE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOF TOP AIR CLEANER ELEMENT RIGHT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 117 [46.1] OVERALL HEIGHT Imo-- 888 [35.0] OVERALL WIDTH REAR VIEW WEIGHT DATA ENGINE/KW ENCLOSURE MATERIAL WEIGHT GENSET ONLY KG ILBSI WEIGHT SHIPPING SKID KG [LBS] SHIPPING WEIGHT KG RBS] 2.4L 32KW AL 658 (1225] 44 [98] 800 ]13231 2.4L 38KW AL 58011235] 44 ]98I 805113331 NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. EAR ENCLOSURE COVER PANEL SEE NOTE 4 USTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 47—•- (1.8] TYP DIMENSIONS: MM [INCH) 759 [29.9] —� DOOR TYP 1857 [73.1] TYP 1950 (76.8) VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR • 58 [2.3] OVERALL LENGTH TYP efeiT M4 • • • • • • • • • • •• ••• •• • • • •• • • • ••• • ••• • • • • • • • • • • • • • • • •• ••• • • • • • • • • • ••••• • • •• • • I • • • • • • • e • • • • • • • • • • • • I • • • • • • • • • • • • • • • • • • • • • • • • I • • • • •• •• • • • •• •• • • • • • • •••. • • 4) w�. d 0 IkeiC C� r�F C) m z m 50 TYP [2.0] ••• • • • • • •• •• • •• • • ••• • • •• •• • •• • • ••• • •• •• •• • ••• • •• •• • • • • •• • •• • • • • • • • • • • • • • • • • • • • • • • • •• OOOOO • • • • • • ••• • • • • • • • • • • • •••• • ••• • • 13,5 X 29.5 .• ••• •• • • • •• MOUNTING SLOTS *NOTE - STUB -UP AREA FOR HIGH eIQD LO V TAGL•C0INNEC?IONS. • 4X CIRCUIT BREAKER, NEUTRAL AND CUSTO R IDNF�T1)NIA. • • • • • • • • • •• ••• • • • • • •• 1733 [68.2] TOP VIEW 1750 [68.9] TYP MOUNTING SLOTS 1950 [76.8] LEFT SIDE VIEW 12 [.5]-► 162 [6.4] *STUB -UP AREA - 162 [6.4] *STUB -UP AREA 9 [.4] 217 [8.5] 25-► [1.0] TYP 786 [30.9] 51 [2.0] EMOVABLE STUB -UP ACCESS COVER (SHIPPED LOOSE WITH GENERATOR) TO BE INSTALLED DURING GENERATOR INSTALLATION 850 [33.5] 838 [33.0] TYP MOUNTING CENTERS 888 [35.0] REAR VIEW 116 [4.6] (Z 10 Z) 8-89Z6)10# 6u!MeJa CO 1< O C z m 11 Protector® QS Series . ... • .. .. . . . .. . • • . . •. •. •. •. • • • . •. •... •• • . •• •• • •• • . ..• . •• • • •. • . • • •. • • . • • •• • •• . . • •• • • • • . • • • • •• •• . . • ... . . •. • • • • . • •• . • • •• . . •• . • • • • • • • • .... • •• • ... •.• •.. ••• • • Job Address Job Description: Contractor Information ,•, ;•.1Q97NV95St ;I,Afali6hores433138 Pour Concrete Pad for 38kw LPG fired Generator Pad weight = 3,200 lbs or greater All Quality Electric 14500 NW 16 Ct Miami, Fl. 33167 305-968-7832 twrier1nfeFination Residence of Sean Shea Notes: Combined height of generator and slab will be 50" 85" Long 43'Witle \ \ \ \ \ 24" high Concrete Pad 85" Long X 43" Wide X 24" High 3000 PSI W/ #5 Reinforcing Bars Each Way Sakrete Cement, Weed block material applied 4/10/2018 MAP OF S OT TNDARY S-LTI NORTH SCALE 1 "=30' m z LOT 21 BLOCK 81 RP 1!2' NO CAP BLOCK CORNER 3B Z. W GILA l uci ir M1 e, 161dJ q Vs- G tCr. •r prio •• RD /ANDER P OF LOT 22 3 BLOCK 81 ra o • • `+ .'s..u.4 r'rti:,>l.:it, i, ':+6'`s.k:i �:s. v, ,.; e, � ;•' • 4-.: }�` ;w�•c92- ASPHALTPAVB � �v-4.5,.wai 2 J .• - ' '�.jg• v :r . x : e va tckS;-rim H}= _" , a,Y'� i;ri`- to 35.32' 1.L'04I. 3w991L LOOS EAST 112 PORTION OF LOT 22 BLOCK 81 35.12' • • • • • • 41.1• • • r POOL • • • to 1 4 LOT 23 BLOCK 81 (50.001 (50.001 243 48.7" LOT 24 BLOCK 81 10A' WEST 1n PORTION OF LOT 25 BLOC( 81 EMAINDER F LOT 25 $ LOCK 81 3 w• LOT 26 BLOCK 81 LEGEND ABBREVIATIONS: A = ARC DISTANCE AC = AIR CONDITIONER PAD BCR = BROWARD COUNTY RECORDS BLDG = BUILDING BM = BENCH MARK BOB = BASIS OF BEARINGS CBS = CONCRETE BLOCK & STUCCO (C) = CALCULATED C&G = CURB & GUTTER CLF = CHAIN LINK FENCE COL = COLUMN D.E. = DRAINAGE EASEMENT D.M.E. = DRAINAGE & MAINTENANCE EASEMENT D/W = DRIVEWAY EB = ELECTRIC BOX ENC. = ENCROACHMENT EP = EDGE OF PAVEMENT EW = EDGE OF WATER FDH = FOUND DRILL HOLE FF = FINISHED FLOOR ELEVATION F1P = FOUND IRON PIPE (NO ID) AR = FOUND IRON ROD (NO ID) FN = FOUND NAIL (NO ID) FPL = FLORIDA POWER & UGHT TRANSFORMER PAD LE. = LANDSCAPE EASEMENT LM.E. = LAKE MAINTENANCE EASEMENT (M) = MEASURED MDCR = MIAMI-DADE COUNTY RECORDS FAH = MAN HOLE ML = MONUMENT UNE (P) = PLAT PB = PLAT BOOK PC = POINT OF CURVATURE PCP = PERMANENT CONTROL POINT PE = POOL EQUIPMENT PAD PG = PAGE PI = POINT OF INTERSECTION Pt. = PLANTER POB = POINT OF BEGINNING POC = POINT OF COMMENCEMENT PRC = POINT OF REVERSE CURVATURE PRM = PERMANENT REFERENCE MONUMENT PT = POINT OF TANGENCY R = RADIUS DISTANCE (R) = RECORD R/W = RIGHT-OF-WAY RES = RESIDENCE SIP = SIP LBj8023 SND = SET NAIL & DISK LB18023 STL = SURVEY TIE LINE SINK = SIDEWALK (TYP) = TYPICAL UB = UTIUTY BOX U.E. = UTILITY EASEMENT W/F = WOOD FENCE CERTIFICATE OF AUTHORIZATION / LB-8023 Survey Pros, Inc. 8306 MILLS DRIVE SUITE 148, MIAMI, FL.,33183 Tel: 305.767.6802 www. survey- pros -com • • • • • •• • • • • • • • • • • • • • • •• •• • • • • • PROPERTY ADDRESS: : • • • 1053 NE 95TH STREET. MIAMI SHORES, P..•33111 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • •• • • • • • LEGAL DESCRIPTION: THE EAST 1/2 OF LOT 22. ALL OF LOTS 23 AND 24. AND THE WEST 1/2 OF LOT 25, BLOCK 81, OF MIAMI SHORES SECTION 3, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 10. PAGE 37. OF THE PUBUC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. FLOOD ZONE INFORMATION: BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY REVISED ON 09/11/09 AND INDEX MAP REUSED ON 09/11/09 THE GRAPHICALLY DEPICTED BUILDING(S) SHOWN ON THIS MAP OF SURVEY IS WITHIN ZONE X. BASE FLOOD ELEVATION N/A COMMUNITY NAME & NUMBER MIACyII SHORES 120657 MAP & PANEL NUMBER 1208600306 SUFFIX L SYMBOLS: • = TELEPHONE RISER 0 = CABLE TV RISER • = WATER METER X 0.00 = ELEVATION (00') = ORIGINAL LOT DISTANCE A = CENTRAL ANGLE = CENTER UNE WV = WATER VALVE = CURB INLET = FIRE HYDRANT = UGHT POLE O = CATCH BASIN UTILITY POLE ® = DRAINAGE MANHOLE ()= SEWER MANHOLE = IRON FENCE = WOOD FENCE -•-•- = CHAIN LINK FENCE -- - = OVERHEAD UTILITY WIRE LEECH a'_LLL.LL t 1_I_LLLLI ASPHALT CONCRETE PAVERS TILES x COVER - SURVEYOR'S NOTES: 1. ELEVATIONS WHEN SHOWN REFER TO 1929 NATIONAL GEODETIC VERTICAL DATUM (NGVD 1929). 2. NO ATTEMPT WAS MADE TO LOCATE FOOTINGS/FOUNDATIONS, OR UNDERGROUND UTILITIES UNLESS OTHERWISE NOTED. 3. THE LANDS SHOWN HEREON HAVE NOT BEEN ABSTRACTED IN REGARDS TO MATTERS OF INTEREST BY OTHER PARTIES, SUCH AS EASEMENTS. RIGHTS OF WAYS, RESERVATIONS, ETC. ONLY PLATTED EASEMENTS ARE SHOWN. 4. THIS SURVEY WAS PREPARED FOR AND CERTIFIED TO THE PARTY(IES) INDICATED HEREON AND IS NOT TRANSFERABLE OR ASSIGNABLE WITHOUT WRITTEN CONSENT OF THIS ARM. 5. ALL BOUNDARY UMIT INDICATORS SET ARE STAMPED LB# 8023. 6. THE BOUNDARY OMITS ESTABLISHED ON THIS SURVEY ARE BASED ON THE LEGAL DESCRIPTION PROVIDED BY THE CLIENT OR ITS REPRESENTATIVE. 7. FENCE OWNERSHIP IS NOT DETERMINED. & ADDITIONS OR DELETIONS TO THIS SURVEY MAP AND/OR REPORT BY SOMEONE OTHER THAN THE SIGNING PARTY(IES) IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY(IES). 9. BEARINGS WHEN SHOWN ARE TO AN ASSUMED MERIDIAN. THE CENTERUNE OF NE 95TH STREET HAS BEEN ASSIGNED A BEARING OF N90'00'00"E. CERI'iriiD TO: SEAN SHEA SURVEYOR'S CERTIFICATE: __ _ _ I HEREBY CERTIFY THAT THIS SURVEY IS TRUE. -AND -CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF AS RECENTLY SURVEYED AND DRAWN UNDERMYDIRECTION AND-MttIS THE MINIMUM TECHNICAL STANDARDS SET FORTH BY THE FLORIDA STATE BOARD OF -SURVEYORS AND MAPPERS IN CHAPTER 5J-17 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027 FLORIDA STATUE _ AUTHENTIC COPIES OF THIS SURVEY SHALL BEAR THE ORIGINAL SIGNATURE AND RAISED SEAL OF THE ATTESTING REGISTERED SURVEYOR AND MAPPER SEAL "NICOLAS DEL VENTO PROFESSIONAL SURVEYOR & MAPPER STATE OF FLORIDA LIC. # 6945 DATE OF FIELD WORK: 02/01/18 - JOElt 18012850 DRAM BY: ANC/( CAD FILE: SHEA SHEET 1 OF 1 IlVIlAP (3IF I3CIIJISTIDA,JR-X7 SIJI 4 fzi•sti- okw.ttv-cie,44A JA9014.-4- 1" •••••• •••_ •• 13ei• v-ova •or • IT) BLOCK 81 OF LOT BLOK rr 16.0„czo I 1 WAX c"-i0E-ZES VILLAGE • BU IINC DEPAR11MENT 0000E 150 W • ...-vinrAntniivi'.. ,i4VO4+$4444%,••••%•• A - '•444•%4440‘441%44•%$'4$4-, "4"••••••••••••"41...VVVV•IN,..,,A.,Ny-iik 4%-$444444s$N4sisi••••%,s,Nesh 44 sek444440%1%•"44444444,•4. ,g-44M16,NtsIsININ*&IN,14-1.44NWst.V.sfAtie.S. ;Sal.,. ;$-: -_,..,:ek_si,•-5,7,1k,, =,,...vii. ,-.S..,,PW‘.4-,.z .,6;:,,ii.*Aspaeigrviatair -,-_-„,--,,,,,, ..e_--., ,,-..,,,,,A.,,, --.)ArM, ....,-,4*^',.!:;-,...'3.:.•.-41.:-.• ,.......k.- .±-,-.-,,,,i,,,s.,_,.-.--.1,-.... _.*c`kelt, '•..v. rinf-'."P-4t. n••.'•i,.s•...Z;,-,.,.N,:.-&.t?.,*4*7;,::-.-f.-1eeC-,,n.N)"'c,Z'e4!,!''"'','K,:4,'':;A-',7',':A4-74-44..t',e,•.1I541E.&-54i•Ilu e.t-r4:,...';:',..y.r:C..-..ir;...i.:..'k.,m ..:."_9...A,at,....::....:• ,?..:.1.-...,s'.,--...N.•,...,,i.,tA,„'.'A.. '"W.•l.i:VP•. '.?-:tr-,1-,.t....°.I•.—.S....-:7,:•.,-i:..7.••.:•.M'.,:.VW.0•..E 95TH STFEET: N..:•,,aRNBY PLAT ,1V,7„::,.--::-.77.4.-.4.Z..1.1/41 ,s&-•i,%vh,...4v. ,..:,,.,....1. el / =M.'''• . IT'F ;On noUNTY