Loading...
RF-18-197 (2)Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Parcel Number Issue Date: 1/25120/8 Permit NO. IMF-1-18-197 Permit Type: Roof Work Classification: Fiat Permit Status: APPROVED Expiration: 07/24/2018 Applicant 65 NW 107 Street Miami Shores, FL 33138-4306 1121360070430 Block: Lot: Angela Diaz Vidaillet Owner Information Address Phone Cell Angela Diaz Vidaillet 65 NW 107 Miami Shores FL 33168- Contractor(s) ALL AMERICAN ROOFING INC Phone (954)772-7663 Cell Phone Valuation: $ 18,106.00 Total Sq Feet: 1609 Type of Work: Re Roof Additional Info: REMOVE AND REPLACE EXISTING FLAT RO Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $11.40 $4.13 $2.75 $3.80 $275.00 $9.00 $15.20 $821.28 Pay Date Pay Type Amt Paid Amt Due Invoice # RF-1-18-66229 01/25/2018 Credit Card $ 50.00 $ 771.28 01/25/2018 Check #: 31864 $ 771.28 $ 0.00 Bond #: 3618 Available Inspections: Inspection Type: Tin Cap Final Roof Roof in Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certi tte bregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. F l orize the bove:named contractor to do the work stated. Autho • ure: Owner / Applicant / Contractor / Agent January 25, 2018 Date Building Department Copy January 25, 2018 1 A Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED JAN 2 5�1018 ILXi FBC20 BUILDING Master Permit No. g—C I p I11 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING • ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: (\() N ( ' (Y( S 4- City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 1 \ ---a 1 3(0 -6 t 1 6)430 Is the Building Historically Designated: Yes NO Occupancy Type: _ Load: Construction Type: VFl000d Zone: BFE: FFE: OWNER: Name/-1 (Fee Simple Titleholder): All G & h t A 71` A (done#: Address: CP.5— N W 1 ‘-1 I— `J City: illA 9J I/1,1,r, S Q e S State: C Tenant/Lessee Name: Phone#: Email: Zip: 3 J I X CONTRACTOR: Company Name: All i�' {'' l C) ('Jh"J (0 P-! Y� Phone#: (Q1� W )/� 7Co , J Address: qI) W e 12-4s P'c�-- (a A `� City: ©©a� (1 P _v_ State: f ' Zip: 5�7 0� Qualifier Name: ,) DSO T L (ta, . V&Acis-4 Phone#: 7 9 �//�'7./� " 7 State Certification or Registration #: CC 0 S.- S &Certificate of Competency #: DESIGNER: Architect/Engineer: - Phone#: Address: - City: State: +\ Zip: 1 ' Value of Work for this Permit: $ 1 rj I ) . 66 Square/Linear Footage of Work: I IP 6 q Type of Work: ❑ Additi n ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Cyr r _Ov I • J- P.•e p ) 2f ' EX (2 J 1 hSy r 1 mot//`- 006 r Specify color of color thru tile: " .- t Submittal Fee $ Permit Fee $ '' CCF $ CO/CC $ r Scanning Fee $ . - -- Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ 71 I. `" (Revised02/24/2014) Bonding'Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address s City + State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that .a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that d copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved • • • • reinspection fee will be charged. Signa OWNER or AGENT Signature The foreg• ing instrument was acknowledged before me this The foregoing instrum nt was acknowledged before me this ,201- ,by IA day of eA UC, 2_ , who s personally kno to me d'4uho has produced as me or who h.s produced W day of C( , 20 1 d identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: APPROVED BY MONALISA GIPSON s`1P0.y P��'�'. —�„`c.c Notary Public - State of Florida i Commission # FF 964211 i zc a, • •0 Bonded thro gh National N-tar Assn. Plans Examiner jwho is rsonally known identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Structural Review MONALISA GIPSON Notary Public - State of Florida Commission # FF 964211 Bonded through National Notary Assn. by as Zoning Clerk (Revised02/24/2014) To: Re: Miami Shores Building Department 10050 N.E2nd Avenue Miami Shores, Florida33138 Tel: (305). 795.2204 Fax (305) 756.8972. OWNERS'S AFFIDAVIT OF. EXEMPTION ROOF TO'WALL CONNECTION HURRICANE MITIGATION, RETROFIT FOR: EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. Miami Shores Village Building Department 10050 ;N E 2nd Ave Miami Shores, Fl33138'. Owner's Name: /fyeilet (3 c.2 V'i Date: Property Address: (QC fVc,.i 107 S+, / 1,1 a.,: Shedy Ft- 33 ( ( Roofing Permit Number: Dear Building Official: I L(4 c i .t,'; &.(Ie�- � certify that) ; am not required:to retrofit the roof to wall connections of my ' ding because: V:efirstTeldgtion-fiir tfie structurefor purpose of ad valorem taxation is less than $300000.007 Please attach proof of °ad valorem taxation. ' he building was constructed in compliance with the provisions' of the Florida Building Code (FBC) or with the provisions of 1994 edition?of t • th Florida Building Code (1994 SFBC) Si. ature State of Florida County of Dade The undersigned, being the first duly sworn Sworn to and subscribed before me this /or- or- ,,,,,, MONALfit(fiF cafe o,+a ,,,,, Notary Public - State of Florida . Commission # FF 964211 My Comm. Expires Mar 27, 2020 vJ P, Bonded through National Notary Assn. , deposes, and says that he/she is the owner for the above property mentioned. day of ()VC-/ Notary Public, Sate of Florida'afLarge • 'When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC:then you;must provide a building application from a General Contractor for the. Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 8/30/2017 r _,1•1 Property Search Application - Miami -Dade County When buying real estate property, you should not assume that property taxes will remain the same. Whenever there is a change in ownership, the assessed value of the property may reset to full IMPORTANT market value, which could result in higher property taxes. Please use our Tax Estimator to approximate your new property taxes. MESSAGE The Property Appraiser does not send tax bills and does not set or collect taxes. Please visit the Tax Collector's website directly for additional information. Address Owner Name Folio SEARCH: 65 nw 107 st PROPERTY INFORMATION Folio: 11-2136-007-0430 Sub -Division: DUNNINGS MIAMI SHORES E)R NO 3 Property Address 65 NW 107 ST Miami Shores, FL 33168-4306 Owner ANGELA DIAZ VIDAILLET s Mailing Address 65 NW 107 ST MIAMI SHORES, FL 33168 PA Primary Zone 0800 SGL FAMILY - 1701-1900 SO Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half Floors Living Units Actual Area Living Area Adjusted Area Lot Size Year Built Suite 1 1 2,768 Sq.Ft 1,975 Sq.Ft 2,127 Sq.Ft 9,150 Sq.Ft 1938 http://www.miamidade.gov/propertysearch/#/ 1/3 8/30/2017 Property Search Application - Miami -Dade County Featured Online Tools Comparable Sales Non -Ad Valorem Assessments Property Record Cards Property Taxes Report Homestead Fraud Tax Estimator Value Adjustment Board ASSESSMENT INFORMATION Year Land Value Building Value Extra Feature Value i Market Value Assessed Value TAXABLE VALUE INFORMATION COUNTY Exemption Value Taxable Value SCHOOL BOARD Exemption Value Taxable Value CITY Exemption Value , Taxable Value REGIONAL Exemption Value Glossary PA Additional Online Tools Property Search Help Report Discrepancies Tax Comparison TRIM Notice 2017 $196,886 $220,677 $1,463 $419,026 2016 $164,440 $148,119 $1,476 $314,035 2016 Aerial Photography 60ft 2015 $164.440 $148,159 $1,232 $313,831 $334,878 $253,757 $230,689 2017 $50,000 $284,878 $25,000 $309,878 $50,000 $284,878 ........................................ _......................... $50,000 2016 $0 $253,757 $0 $314,035 $0 $253,757 $0 2015 $0 $230,689 $0 $313,831 $0 $230,689 $0 http://www.miamidade.gov/propertysearch/#/ 2/3 8/30/2017 4 Property Search Application L Miami -Dade County Taxable Value BENEFITS INFORMATION ? Benefit Non -Homestead Cap Portability P:. Homestead Second Homestead Type Assessment Reduction Assessment Reduction Exemption Exemption Note: Not all benefits are applicable to all Taxable Values (I.e. County, School Board, City, Regional) FULL LEGAL DESCRIPTION DUNNINGS MIAMI SHORES EXT NO 3 PB 42-33 LOT 11 BLK 211 LOT SIZE 75.000 X 122 OR 17007-5263 1195 1 COC 25349-2640 01 2007 1 $284,878 $253,757 $230,689 2017 $84,148 $25,000 $25,000 2016 $60,278 F SALES INFORMATION i Previous Sale Price OR Book -Page Qualification Description Previous Owner 1 j05/02/2016 $500,000 30067-2379 Qual by exam of deed PETRA HINKE &H UWE FRICKER 01/01/2007 $590,000 25349-2640 Sales which are qualified 10/01/2006 $0 25151-0643 Sales which are disqualified as a result of examination of the deed 05/01/2005 $389,000 23467-0761 Sales which are qualified 11/01/1995 $88,000 17007-5263 Sales which are qualified 04/01/1989 $85,000 14075-3182 Sales which are qualified 10/01/1979 $75,000 10548-1240 Sales which are qualified For more information about the Department of Revenue's Sales Qualification Codes. �r . 2017 2016 2015 LAND INFORMATION { Land Use 1GENERAL Munl Zone 2015 $83,142 R-14.25, R-15 PA Zone 0800 - SGL FAMILY - 1701-1900 SQ Unit Type Front Ft. Units Calc Value 75.00 $196,886 BUILDING INFORMATION Building Number 1 1 Building Sketches Available! EXTRA FEATURES Description Chain -link Fence 4-5 ft high Patio - Concrete Slab w/Roof Aluminum or Fiber Sub Area 1 2 3 Year Built 1938 1957 1967 Actual Sq.Ft. 1,346 1,214 208 Living Sq.Ft. 1,346 629 Year Built 1985 1985 AdJ Sq.Ft. Calc Value 1,346 $139,648 712 $73,870 .0 69 $7,159 Units 65 160 Calc Value $462 $1,001 http://www.miamidade.goy/propertysearch4/ 3/3 ACORO® �� CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) 12/22/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Frank H. Furman, Inc. 1314 East Atlantic Blvd. P . 0 . Box 1927 Pompano Beach FL 33061 CONTACT Melissa Rhinehardt NAME: lac No. extt: (954) 943-5050 FAX No): (954)942-6310 E-MAIL ADDRESS: mel@furmaninsurance.com INSURER(S) AFFORDING COVERAGE NAIC # INsuRERA:Tokio Marine Specialty Insurance 23850 INSURED All American Roofing Inc 944 W Prospect Road Oakland Park FL 33309 INSURERa:National Fire Ins Of Hartford 20478 1NSURERcAmerican Guarantee & Liability Ins 26247 INSURER D :Valley Forge Ins 20508 INsuRERE:Continental Casualty Co 20443 INSURERF: COVERAGES CERTIFICATE NUMBER:Dec 17 all line no forms REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSELXVG SUBR POLICY NUMBER POLICY EFF IMM/DD/YYYY) POLICY EXP IMM/DD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY PPK1642325 5/1/2017 5/1/2018 EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE X OCCUR DAMAGETO RENTED PREMISES (Ea occurrence) , $ 100,000 X Contractual Included MED EXP (Any one person) $ Excluded PERSONAL 8,ADVINJURY , $ 1,000,000 GEN•L X AGGREGATE X LIMIT APPLIES jEg-i PER: LOC GENERAL AGGREGATE , $ 2,000,000 PRODUCTS - COMP/OPAGG $ 2,000,000 Policy Aggregate Cap $ 5,000,000 B AUTOMOBILE X X LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS _ X SCHEDULED AUTOS NON -OWNED AUTOS 1015011990 5/1/2017 5/1/2018 COMBINED SINGLE LIMIT • (Ea accident) $ 1,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ Medical payments $ 2,000 C X UMBRELLA LIAB EXCESS LIAB — OCCUR CLAIMS -MADE AIIC534619111 follows form over OL, AL and EL 5/1/2017 5/1/2018 EACH OCCURRENCE $ 5,000,000 AGGREGATE $ 5,000,000 DED X RETENTION$ 0 $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICED MandatoryEMBER in NH EXCLUDED? (Mandatory ) If yes, describe under DESCRIPTION OF OPERATIONS below Y / N N N / A 1077146872 12/31/2017 12/31/2018 X PER OTH- STATUTE ER E.L. EACH ACCIDENT $ 1,000,000 E.L.DISEASE - EA EMPLOYEE $ 1,000,000 E.L. DISEASE - POLICY LIMIT $ 1,000,000 E Leased/Rented Equipment $1,000 Deductible 2076243939 5/1/2017 5/1/2018 Limit 50,000 Max Per Item 25,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more apace is required) Roofing Contractor CERTIFICATE HOLDER CANCELLATION (305)756-8972 13057568972@efaxsend.com Village of Miami Shores Building Department 10050 N.E. 2nd Ave. Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Dirk DeJong/TP © 1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD ACORD 25 (2014/01) INS025 (201401) RECEIVED JAN25 Master Permit No. yi 2t t , BL(�G � � Florinta 8 ll • ing C • ' StSUBJh sditicEnP T ECT j O COMPLIANCE High -Velocity Hurricane Zone UniforrniPermit`Aicat ppiion For1-1-1 ALL FEDERAL . Section A(General Information) Contractor's Name 4/1 , ('/( 612/ r r " &jr • • • ••• • • • Process No... Job Address 5— N&) l 0 J S '+ /q[ � Q % ems(' •• •• aV ow Slope O Asphaltic Shingles O New roof 0 Repair Low Slope Roof Area (SF) 'ROOF CATEGORY O Mechanically Fastened Tile 0 Metal Panel/Shingles O Prescriptive BUR-RAS 150 ROOF TYPE 0 Maintenance ROOF SYSTEM INFORMATION Steep Sloped Roof AREA (SSF) • • ii • •• • • I.•••. • I • • • • • • I ❑ Mortar/Adhesive Sit Tiles • 1• • • O Wood Shingletnhates • • • • • • 1• •• • •• eioofing • • • • Is • •.•. • •.• 0 Recovering Total (SF) / V 1 Section B (Roof Plan) Sketch Roof Plan; Illustrate alllevels and sections; roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 9-\ to FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) 15.37 LNTERNATIONAI CODE COUNCIL Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun8, 2015 10 32:12 AM pursuant to License. Agreement, No further reproductions authorized. i 1 1 I 1 I 1 I 1 1 I 1 1 1 1 I 1 I I 1 1 1 1 1 1 1 1 1 1 1 r 1 1 1 .1 1 1 1 1 i. 1 1 1 1 ROOF. ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity HurricaneZoneUniformPermit' Application Form. Section C(Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component s not used, identtify'as`"NA") System Manufacturer GAP Product Approval No.: /11--(O3,o , Design ([// Wind Pressures, From RAS 128 or Calculations:; P1: T2 _ 7 P2: , 71.7 . P3: /0% .0 Max. Design Pressure, fromth pecific product approval system: - 3S�e� Lam, Deck: Type: L)C,iOOP... Gauge/Thickness: (r1I Slope:/° Anchor/Base°Sheet & No. of Ply(s) _ 7S, Anchor/Base Sheet Fastener/Bondi g i7i-ur«, i kc&k. PGA 4---10 Ic. scha ._ Insulation Base Layer: 1 C3 Base Insulation Size and Thickness:4- �C 3 Base Insulation Fa terser/Bondin Material: 1• Top Insulation Layer: A) Top Insulation` Size and Thickness: Top Insulation Fastener/Bonding Material: 61Y1 it r± r 2 C Jc-Lath.. Base Sheet(s)'& No. of Ply(s): Strut Top Ply F ener/BondingJv1a e t QJQMI • • • • • • • • • • • • • • • • 1 •.••.• Surfacing`.. • •• • FastenerSpacing-for Anchor/Base. SheeiAtiacment:� • ..•••p •.• •1 Field: / "oc@Lap, # Rows , .@ •fMoc •• . ...1 Perimeter: " oc @.Lap, #'Rows . . @ :' . oc.• •. • 1 p P, • 1 Corner: 'b " oc'@ Lap, # Rows 7` 0- : oc, • • 1, • 1 Numberof Fastener Per Insulation Boa+d:, • • • • •1 ••• • Field Perimeter Corner Illustrate Components Noted and,Details as Applicable: Woodblocking, Gutter,Edge' Termination", Stripping, Flashing, Continuous :Cleat; Cant. Strip, Base Flashing, Counterflashing, Coping, Etc: Indicate: Mean 'Roof `Height, Parapet Height„'Height of Base Flashing Component Material, Material Thickness, Fastener Type, Fastener, Spacing or Submit:, Manufacturers Details.' that Comply,with, RAS `11;1;and:Chapter 16. S tit/ QkJPt✓ I ThlSn tl, mop r .... 'A)/fit, 24 "Cleat. Base Sheet Fastener/Bondin Material: jacut_ jct.; PlySheet(s) & No. of Ply(s): �p Sm.sfl irk) PlySheej Fastaner/13g Merial; Top Ply: O 15.38 INTERNATIONAL CODE COUNCIL.' c,e,,POk FT. . FT. Tolgser N Parapet Height 13j Mean Roof Height 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 .1 i 1 I FLORIDA BUILDING CODE —'BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOMS CONSIDERATIONS` ' ' '• • • • 1524.1 Scope. As it pertains to the section, it is theresponsibility of roofing -contractor to pf oVcre the owner witr the required roofing permit, and to explain to the owner the content of the section. The provisions oaf Sectipn1 1t 2 govern the minimum requirements and standards of the industry for roofing system instailatiias.l dditionalli; the. following items should be addressed as part of the agreement between the owner ant the cep/ actdr. The ow r'& initial in the -designated space, indicates that the item has been explained. • • • 6. 1 r/" Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge.wail or other roof extension may block this discharge if overflow` scuppers (wall outlets) are not provided. It ma be necessary to install overflow scuppers in accordance with the requirements of Sections R44024403 d R4413. . •• _Renailing wood decks: When replacing roofing, the existing wood roditiecit may Nave tq• be renailed in accordancewith the current provisions of Section R4403. (The roof deck is usually concealed prior to removing they existing roof system). 4\i/ Exposed' Ceiling: Exposed, open beam ceilings are where theunderside of th roo f oof decking can be viewed from below: The owner may wish to maintain the architectural appearance;; therefore, roofing'nail penetration of the underside of the decking may notbe acceptable. This provides,the option of maintaining the appearance. r/Agent's Signature Date Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number ;Date • • • • • • • • • • • APPROVED ASSEMBLIES Membrane Type: Deck Type 1I: Deck Description: System Type A(1): All General and Sys Fire Barrier: o tional) PO. Anchor sheet: Fastening Options: MIAMI•DADE COUNTY APPROVED SBS Wood, Insulated 19/32" or greater plywood or wood plank • • • • • • • • •••• • Anchor sheet mechanically fastened, all layers of insulation adAMred'with • • • • •' •••••• approved asphalt. • • •••••• • • tern Limitations shall apply. • "" • � •• •.. • • • FireOut" Fire Barrier Coating, VersaShield® Fire -Resistant Ravf:Deek Proteectiorr •• • or Securock® Gypsum -Fiber Roof Board. • • " GAFGLAS® #80 Ultima" Base Sheet, GAFGLAS® StrataventnEli• minatorn: • • •: • Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Hgat-mod" Smootll or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastend to deck,s•• •' described below. GAFGLAS® Ply 4, GAFGLAS® FlexPly" 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf. See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® FlexPly" 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec" #12 Fastener, Drill-Tec" #14 Fastener or Drill-Tec" XHD Fastener and Drill-Tec" 3" Steel Plate, Drill- Tec" AccuTrac® Flat Plate or Drill -Tee' AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf. See General Limitation #7) GAFGLAS® FlexPly" 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf. See General Limitation #7) GAFGLAS® #80 Ultima" Base Sheet, Ruberoid® 20, Ruberoid® Mop Smooth base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf. See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec ' #12 Fastener, Drill-Tec" #14 Fastener or Drill-Tec" XHD Fastener and Drill-Tec" 3" Steel Plate, Drill-Tec" AccuTrac® Flat Plate or Drill-Tec" AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 8 of 30 •••••• • • • •••••• • • •••••• • • ••••• • • ••••• •••••• •• •••••• • • •••••• • • Fastening Any of above anchor sheets attached to deck approved annular ring shank nails Options: and 3" inverted Drill -Tee insulation plates at a fastener spacing of 9" o.c. at the (Continued) 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf. See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tect #12 Fastener, Drill -Tee #14 Fastener or Drill -Tee XHD Fastener •... and Drill -Tee 3" Steel Plate, Drill -Tee AccuTrac® Flat Plate or Drill•.TecTM • • • • • ' • AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side' ••. lap. The other rows are equally spaced approximately 9" o.c. in the ftl4d bf the • sheet. (Maximum Design Pressure —75 psf. See General Limitation #7) • ....• • • • .. • One or more layers of any of the following insulations. • • • • • '• •.• . Insulation Layer Insulation Fasteners Fastener , (Table 3) ; Density/ft2 • EnergyGuardTM Polyisolnsulation, EnergyGuardTM Polyiso RA Insulation, • EnergyGuardTM Polyiso RN Insulation, EnergyGuardTM RA Composite Polyiso Insulafien • • •• • •• Minimum 1" thick N/A N/A •' • Structodek® High Density Fiber Board, EnergyGuardTM Perlite Recover Board Minimum 'A" thick N/A N/A EnergyGuardTM Perlite Roof Insulation Minimum'/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full moppi g of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a'ply of GAFGLAS® Stratavent® EliminatorTM Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (O do Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Ply 4, GAFGLAS FlexPlyt 6, GAFGLAS® Stratavent® EliminatorTM Perforated Venting Base Sheet (laid dry), Ruberoid® Mop Smooth, Ruberoid® 20, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS Heat -Weld' 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). Ply Sheet: (Optional)One or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPlyt 6 , GAFGLAS® #80 Ultima Base Sheet, Ruberoid® Mop Smooth Ruberoid® 20 adhered in a full mopping of approved asp a pp ie within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid® 20, Ruberoid® 30, Ruberoid® EnergyCapr" 30 FR SBS Membrane, Ruberoid® 30 FR, Ruberoid® Mop Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, RoofMatcht SBS Modified Granular, Ruberoid® Mop Plus, Ruberoid®Moz FR or Ruberoid® Dual FR fully adhered in an approved asphalt at an application rate of 25 lb./sq. ± 15%. MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 9 of 30 • •• • • Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® Mineral Surfaced Cap Sheet • or GAFGLAS®EnergyCap' BUR Mineral Surfaced Cap Sheet a4her .in a full • • • mopping of approved asphalt applied within the EVT range and at a rate of 20:40 • • • io lbs./sq. • • 3. Topcoat® Membrane, Topcoat® MB Plus (to be used as a primer wig) Xopcoatl • • • • Membrane) or Topcoat® Surface Seal SB applied at 1 to1.5 gal./scr. • •.• • • • Maximum Design Pressure: See Fastening Options MIAMI•DADE COUNTY APPROVED . • . • • • • • • • •• • • ••• •• • ••• • • • • • •• • • • • NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page"10 of 30 MIAMI•DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/economy • .... • • • • • .. • • • • • .+ •• • This NOA is being issued under the applicable rules and regulations governing the use oftoostrtiction: •..� materials. The documentation submitted has been reviewed and accepted by Miami -Dade Cotuntl RER f : • : Product Control Section to be used in Miami Dade County and other areas where allowedkby t •' • Authority Having Jurisdiction (AHJ). • • • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade•Geuniy) • • •• •• • • reserve the right to have this product or material tested for quality assurance purposes. If this product or•• ' material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or ' change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0611.01 and consists of pages 1 through 30. The submitted documentation was reviewed by Jorge L. Acebo. MIAMFDADE COUNTY APPROVED •• NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 1 of 30 ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: Roofing Modified Bitumen APP/SBS Wood -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICAI'N • TABLE 1 • Product Matrix' 102 SBS Membrane Adhesive GAFGLAS® #75 Base Sheet GAFGLAS® #80 Ultima'' Base Sheet GAFGLAS® FlexPly' 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCap'" BUR Mineral Surface Cap Sheet GAFGLAS® Stratavent® Eliminator' Perforated Venting Base Sheet GAFGLAS® Stratavent® Eliminator' Perforated Nailable Venting Base Sheet Ruberoid® SBS Heat -Weld' Smooth Ruberoid® SBS Heat -Weld' Granule RoofMatch' SBS Modified Granular Ruberoid® SBS Heat -Weld'' 170 FR MIAMI•DADE COUNTY APPROVED Dimensions 5 gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 107 sq. ft. (9.9 m2) 39.37" (1 meter) Wide Test Specification ASTM D3019 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 ASTM D3909 ASTM D3909 ASTM D4897 ASTM D4897 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 • • • • • • • • • • • Product••• 4, •••• • • • Descriptibhf • • •• • ••• Fiber reinforced rubber et1 ld-applcad • adhesive for modified bikxxeie roof • systems. • ;• • Type II asphalt impregnhtedaad coated •• • •• • glass mat base sheet. • • • ••• • Type II asphalt impregnated and coated, fiberglass base sheet. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules: Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCote" Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. A nailable, fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -woven polyester mat coated with polymer -modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with SBS polymer -modified asphalt,and surfaced with colored mineral granules. Non -woven polyester mat coated with fire retardant polymer -modified asphalt and surfaced with mineral granules'. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 2 of 30 Product Ruberoid® SBS Heat -Weld' Plus Ruberoid® SBS Heat -Weld- Plus FR Ruberoid® EnergyCap'" SBS Heat -Welt Plus FR Ruberoid® SBS Heat-WeldT"' 25 Ruberoid® Mop Granule Ruberoid® Mop Smooth Ruberoid® Mop Plus Ruberoid® Mop 170FR Ruberoid® Mop FR Ruberoid® Torch Smooth Ruberoid® Torch Granule Ruberoid® EnergyCap- Torch Granule FR Ruberoid® EnergyCap'" Torch Granule Plus FR RoofMatch' APP Modified Granular Ruberoid® Torch FR MIAMI•DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 107 sq. ft. (9.9 m2) 1 meter (39.37") Wide Test Specification ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 Product Description Non -woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer -modified asphalt and surfaced with mineral granules • • • • • Non -woven polyesster m'it coated with fire retardant polymemoodified asphalt and surfaced with mirtMtal'granules and with factory applied ERYgyt ote. • • Non -woven polyester mat coaled with polymer -modified 0210lt and•snootti surfaced. • Non -woven polyester mat coated with polymer-modifie4 aspliNit and sort`aced with mineral granttl0s. ' . • •• •• • • Non -woven polyester mat coat&dWith polymer -modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer -modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with APP modified asphalt and smooth surfaced. Non -woven polyester mat coated with APP modified asphalt and surfaced with mineral granules APP modified cap membrane with a torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCoteTM. APP modified cap membrane with a torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCoteTM. Non -woven polyester mat coated with APP polymer -modified asphalt and surfaced with colored mineral granules. Non -woven polyester mat, coated with fire retardant asphalt modified bitumen membrane with granule surface. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 3 of 30 • • • Product Ruberoid® 20 Ruberoid® 30 Ruberoid® 30 FR Ruberoid® EnergyCap- 30 FR SBS Membrane Ruberoid® Dual FR Topcoat® Elastomeric Roofing Membrane Topcoat® MB Plus Topcoat® Surface Seal SB FireOut- Fire Barrier Coating VersaShield® Fire -Resistant Roof Deck Protection MIAMI-DADE COUNTY APPROVED Dimensions 1 meter (39.37") Wide 1 meter (39.37") Wide 1 meter (39.37") Wide 1 meter (39.37") Wide 39.37" (1 meter) Wide 1, 5 or 55 gallons 5 or 55 gallons 5 gallons 5, 55 gallons 42" x 100' rolls Test Specification ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6162 ASTM D6083 Proprietary ASTM D6083 Proprietary ASTM D226 Product Description SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. .. • • Non -woven fiberglass mat coafe twith fire retardant, polymer-modiiied asphaltand surfaced with minttal;gianules Non -woven fiberglags'Mat coated With fire • retardant, polymer-moaified apalf and surfaced with mirLesalgrdanules an4 kith factory applied Euar'gireote. •.. • Non -woven polyeemarl fiberglass mat coated with file retardant, polymer-. modified asphalt ':ndsti faced•with • mineral granules. •' .".'. An acrylic, water based elastonmeric membrane system designed to protect various types of roofing surfaces. Water based, low VOC primer used to block asphalt bleed -through. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. Low VOC, water -based fire barrier coating. Non -Asphaltic, fire resistant fiberglass - based underlayment. NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 4 of 30 • • • . • . • • • • . . . APPROVED INSULATIONS: Product Name EnergyGuard' Polyiso Insulation EnergyGuard' RA Polyiso Insulation EnergyGuard' RN Polyiso Insulation EnergyGuard' Perlite Recover Board EnergyGuard' Perlite Roof Insulation EnergyGuard' RA Composite Polyiso Insulation Structodek® High Density Fiber Board Securock® Gypsum -Fiber Roof Board APPROVED FASTENERS: Fastener Number Product Name 1. Drill -Tee' #12 Fastener 2. Drill-Tect #14 Fastener 3. Drill-Tec" XHD Fastener 4. Drill-Tec"" AccuTrac® Flat Plate 5. Drill-Tect ASAP 3S 6. Drill-Tec"" AccuTrac® Recessed Plate 7. Drill-Tec'"' 3" Steel Plate 8. Drill -Tee' 3" Standard Steel Plate MIAMI-DADE COUNTY APPROVED Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate/wood fiberboard or perlite composite High density wood fiber Gypsum board TABLE 3 Product Description Carbon steel fastener used in steel or wood decks. Carbon steel fastener used in steel, wood or concrete decks. Carbon steel extra heavy duty fastener used in steel decks. AZ -SS aluminized steel plate for use with Drill- Tec'"' #12 Fastener, Drill - Tee' #14 Fastener and Drill-TecTM #15 Fastener. Drill-Tec"'' #12 fastener with Drill-Tec"" 3" Standard Steel Plate. Galvalume Steel plate for use with Drill -Teed fasteners. Round galvalume steel stress plate for use with Drill-Tece' fasteners. Round galvalume plated steel stress plate with reinforced ribs for use with Drill -Tech" fasteners. Manufacturer (With Current NOA) GAF • ... . .GAF'.... . • • tAF • • . . .... .. . . • •... GAF . • .. • GAF • • 'GAF • • • • Blue:RicJge:FiberBoard, Inc. • • • . • . • • • • • Unit8d. Cafes Gypsum.Corp. • Dimensions Various Various Various 3" x 3" Various 3" x 3" 3" 3" . • . • • . .. • Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF GAF GAF NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 5 of 30 • EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories Trinity Engineering IRT-ARCON Inc. Trinity I, ERD MIAMI-DADE COUNTY APPROVED Test Identifier Description Date 3001276 FMRC 4470 01/28/99 1B9A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/0a'• • . . . R1306 UL 790 • • • 07/22.43:. . • 4483.04 97-1 TAS 114 06/06/9f . . • 02-005 TAS 114 03/a1/0'l• 02-014 TAS 114 .. • .. • 04/9$/Q2 01-039 TAS 114 03/01/02 • . G30250.02.10-2 ASTM D6222 . • 11/} if140• G30250.02.10-3-R2 ASTM D3909 •..• : 06/0341% G31360.03.10 ASTM D6164 03/3ab1$ • G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015 G40620.07.12-2 ASTM D6222 07/17/12 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D5147 01/07/14 G40630.01.14-2A-1-R1 ASTM D6164 04/10/14 G40630.01.14-2B-R1 ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01/07/14 G40630.03.14 ASTM D5147 ,03/06/14 G43190.03.14-1 ASTM D5147 03/06/14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R1 ASTM D5147 05/20/14 G43190.11.13-1 ASTM D6222 11/15/13 G43610.01.14 ASTM D5147 01/22/14 G46160.02.15-2D ASTM D6163 02/03/15 G46160.03.15 ASTM D6163 03/11/15 G46160.09.14-2A ASTM D5147 09/09/14 G46160.09.14-3A ASTM D6164 09/09/14 G46160.09.14-3B ASTM D6164 09/09/14 G46160.09.14-3C ASTM D5147 09/09/14 G46160.12.14-3E ASTM D6164 12/29/14 G6850.08.08 ASTM D6163 08/01/08 G6850.08.08-R1 ASTM D6164 04/14/11 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 02/17/09 SC6870.08.14-R1 ASTM D3909 09/04/14 NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 6 of 30 EVIDENCE SUBMITTED: (CONTINUED) Test Agency PRI Construction Technologies LLC. Momentum Technologies, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier GAF-084-02-01 GAF-122-02-01 GAF-245-02-01 GAF-276-02-01 Rev GAF-306-02-01 GAF-314-02-01 GAF-315-02-01 GAF-369-02-01 GAF-464-02-01 GAF-499-02-01 GAF-500-02-01 AX04C9A Description ASTM D6083 TAS 139 ASTM D6083 ASTM E2178 ASTM D6083 ASTM E96 ASTM D2178 ASTM D2178 ASTM C 1289 ASTM C1289 ASTM D6083 ASTM D6083 ASTM D6162 • . • .. . .• . .... • • .... • . .. .. .. • • • .. . Date 07/08/05 05/07/06 06/10/10 01/04%41V.. .... 07/0lp11 08/23/1.1 08/3/11• . 10/22/12 02/06/fit 03/12714 0342/14 06/t 09 NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 7 of 30 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPlyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeck® Roof Board or Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials • • • • Directory for fire •ratings of this product. • • • • •• • • 2. Insulation may be installed in multiple layers. The first layer shall be attached in•c nplianceP wipe• • Product Control Approval guidelines. All other layers shall be adhered in a full flappi'hg of , • approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., oamlcllanicalW.••. attached using the fastening pattern of the top layer • ••• 3. All standard panel sizes are acceptable for mechanical attachment. When applied i>3 ipprovt • • asphalt, panel size shall be 4' x 4' maximum. • 4. An overlay and/or recovery board insulation panel is required on all applications over closed► cell • foam insulations when the base sheet is fully mopped. If no recovery board is used xlie base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles:24" 8.c.; o>: gttjli'. mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.02 Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 30 of 30 12. Deck: NC Incline: 1 Roofing Systems Page 12 of 47 Iy Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or Tri-P y® Ultra - Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — "RUBEROID® Mop Granule FR" or "RUBEROID® Mop Plus Granule FR" or "RUBEROID® EnergyCapT" Mop Plus Granule FR" fully adhered with hot roofing asphalt. Deck: C-15/32 Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or fiber glass or polyisocyanurate or urethane or perlite/polyisocyanurate composite, butt joints offset a minimum of 6-in. from plywood deck joints. Base Sheet: — One or more plies Type G2 "GAFGLAS® #7S ease Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima"' Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting BaetSR&Y" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically farenerbi fully adhe•ed•with hot it //�� roofing asphalt. •• • • • • !!fi'q Ply Sheet (Optional)_— One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS Vg:g Ply 6" o rraiiP l Ultra- • !! Flexible Ply 6" fully adhered with hot roofing asphalt. • Membrane: — One ply "RUBEROID® Torch Smooth" or 'Tri-Ply® APP Smooth", torch applied or "RUBERO! p Smooth" or • • "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" fully adhered with hot roofing asphalt. • • • • • • • • • Membrane: — "RUBEROID® Moo Granule FR" or "RUBEROID® Mop Plus Granule FR" or "RUBEROID® ER7erg/f "" Mop: lusGrainule FR" fully adhered with hot roofing asphalt. • • • ••• • • • •• • • • •• •• • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "IlensDecl ® Roofboar " or • "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick UnitedStatestypsurryC•o••• "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • • • • • Insulation (Optional): — Perlite or fiber glass or wood fiber or polyisocyanurate or urethane or perlite/ .,l i?ocganurate Qun posite. Base Sheet: — One or more layers Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLASQi3gl�lymaT" • • Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting BaSe•Sl et" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra - Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane:— "RUBEROID® Mop Granule FR" or "RUBEROID® Mop Plus Granule FR" or "RUBEROID® EnergyCapT" Mop Plus Granule FR" mechanically fastened or fully adhered with hot roofing asphalt. 13. Deck: NC Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or fiber glass or wood fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite. Base Sheet (Optional): — One or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima"" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra - Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — One ply "RUBEROID® Torch Smooth" " or "Tri-Ply® APP Smooth", torch applied or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" fully adhered with hot roofing asphalt. Membrane: — One ply "RUBEROID® Mop Granule FR" or "RUBEROID® Mop Plus Granule FR" or "RUBEROID® EnergyCapT" Mop Plus Granule FR" fully adhered with hot roofing asphalt. 14. Deleted. 15. Deck: C-15/32 Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Polyisocyanurate or wood fiber or perlite or glass fiber any thickness, mechanically fastened. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet " or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima"" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically,fastened or fully adhered with hot roofing asphalt. Membrane: — One or more plies "Ruberoid® 30 Granule" or "RUBEROID® 30 Granule FR" or "RUBEROID® EnergyCapT" 30 Granule FR" fully adhered with hot roofing asphalt. 16. Deck: C-15/32 Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum. Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Polyisocyanurate or wood fiber or perlite or or glass fiber, any thickness, mechanically fastened. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima"" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — One or more plies "RUBEROID® 20 Smooth" or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" fully adhered with hot roofing asphalt. Membrane: — One or more plies "Ruberoid® 30 Granule" or "RUBEROID® 30 Granule FR" or "RUBEROID® EnergyCapT" 30 Granule FR" fully adhered with hot roofing asphalt. 17. Deleted. htto://database.ul.com/cgi-bin/XYV/template/LISEXT/ 1 FRAME/showpage.html?name=... 11/30/2017