Loading...
MC-18-1373Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address P • t Permit NO. MC-5-18-1373 Permit Type: Mechanical - Residential Work Classification: A/C Replacement Permit Status: APPROVED Issue Date:-61 8/2018 Expiration: 12/15/2018 Parcel Number Applicant 357 NE 97 Street Miami Shores, FL 1132060135750 Block: Lot: KRISTY JOHNSON Owner Information Address Phone Cell KRISTY JOHNSON 357 NE 97 Street MIAMI FL 33138- (305)539-7249 Contractor(s) Phone A STAR AIR CONDINTIONING AND HE (954)558-2950 Cell Phone Valuation: Total Sq Feet: $ 3,500.00 0 Tons: 2.5 Additional Info: A/C CHANGE OUT Classification: Residential Approved: In Review Comments: Date Denied: Scanning: 3 Date Approved: : In Review Type of Work: Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Amount $2.40 $2.00 $2.00 $0.80 $122.50 $9.00 $3.20 Total: $141.90 Pay Date Pay Type Invoice # MC-5-18-67624 05/21/2018 Credit Card 06/18/2018 Credit Card Amt Paid Amt Due $ 50.00 $ 91.90 $ 91.90 $ 0.00 Available Inspections: Inspection Type: Final Review Mechanical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify tha construction a • • •'ng. • .the e foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating thorize the above -named contractor to do the work stated. , June 18, 2018 Authorize] -'A nature: Owner / Applicant / Contractor / Agent Date Building Department Copy June 18, 2018 1 ro\95\\ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ['BUILDING ❑ ELECTRIC ❑ ROOFING ['PLUMBING J MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 35? N z 91 City: Miami Shores /` �Couunty: Miami Dade Folio/Parcel#: I-3aco -()t? -S-1�XJ Is the Building Historically Designated: Yes NO RECETVED ►' AY 2 2018 FBC201�t Master Permit No. I ` tC-18 Sub Permit No. ❑ REVISION ❑ EXTENSION ['RENEWAL Occupancy Type: Load: CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS Construction Type: Flood Zone: OWNER: Name (Fe Simple Titleholder): risk/ ,_ do E n Address: 35 N State: f , City: m1 QY n ires Tenant/Lessee Na e: Email: NYIS 1 U1l3 0ClO I . COm f A - If Co i ni09 Psue-i-ic _ City: \v l State: 1� Zi'p:: j 4 1 /�/, Qualifier Name: 't On (�. o 1 ' t5 a Phone#qJ ` H I Z State Certification or Registration #: ` Ig I S! —I S Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 3 SOD Square/Linear Footage of Work: CONTRACTOR:ORCompany Name: Address: 39 1;' SLO Phone#: BFE: FFE: &sjal3 532g Phone#: Zip: 3�) 30g Zip: Type of Work: ❑ A itiiC n ❑ Alteration Description of Work: ChG ni5e6LI Phone#: C15L — , l� 2kOO _®'repair/Replace ❑ Demolition Specify color of color thru tile: ` � Submittal Fee $ Go . C Permit Fee $ \ 4"' -DSO CCF $ CO/CC $ Scanning Fee $ Radon Fee $a Q DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ I (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ✓�. �. l Signature NER or AGENT The for : oing instru Tnt was acknowledged before me this The for oin''s' strument was acknowledged before me a this , 20 l Z , by ay of g , 20 � , by who is personally known to JL I CQY\ l o is personally known to me or who has produced DI_ as me or who has produce as identification a ho did .: a an oath. identificatio �d who did . ke an oath. NOTARY PUBLI II NOTARY PU Sign: .�0, V 1..► _ R . ,. gn: Print: '{i v ,, •_ MONICA AGUDELO� orida Seal: ;,==;,ice Commission # FF 923715 al: 4;R r d� ` My Comm. Expires Oct 1, 20195; CONTRACTOR AGUDELO '•: Notary Public - State of Florida iffr Commission # FF 923715 o� %A My Comm. Expires Oct 1, 2019 I'11I,' iti#######ii4i#44i##iii#iiii#4##i4iiiii##iiii4iii4iiii#iii###/#i##ii##i4iii44ii#i#iiii#iiii#######iii4#iiiii 5 IvAt APPROVED BY lans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not /�� I 1 a �1� accept ble. ,y R Job Address (where the work is being done): 359 hi E. (1i S 5htX- S Ft 3 � City: Miami Shores Village County: Miami Dade Zip Code: 33I 3? ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES ❑ NO ARHI Sheet Attached: YES OK NO ❑ Contract Attached: YES ❑ UNIT BEING REPLACED DATA NEW UNIT. R v,N A MANUFACTURER R �N RCHA --) 6A16- AHU or PKG. UNIT MODEL# RI-11T3X/7ST/g/✓JQ RACL-030TA7 COND. UNIT MODEL # RA I63O per. S KW HEAT 5--- _2 . S NOM TONS .2. r ) q CU -II PKG 1) M.C.A AHU1I CU 23 PKG U 30 CU 3 :JPKG 2) M.O.P AHU30 CU 30 PKG AHU CU PKG 3) VOLTS .tot'/a 3 .7 AHU CU PKG PKG UNIT / / PKG UNIT / / 7�40 EER/SEER /3/1 6 YES REPLACING DUCTS YES 4;0 YES 4 REPLACING THERMOSTAT YES YES eri NEW 4"CONCRETE SLAB YES YES i► o NEW ROOF STAND YES 0 YES NEW RETURN PLENUM BOX YES (ND) 1. Minimum Circuit Ampacity (Wire Size): /0 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 30 3. Voltage of Circuit (208/240/480): r 0 4. Size Disconnecting Means: p411 d 3con"9'-AD;3T/►i�� Contractor's Company Name: N SICK- / � tilYIS J State Certificate or egistration GC.Ig I SIQ ' Certificate of Competency No. Signature "� Date: SIK S (Qualifier's signature) Phone: Q L 1' r)(J" 2-1G00 (Revised02/24/2014) This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number : 201281652 Date : 05-18-2018 Model Status : Active Old AHRI Reference Number : 7941343 AHRI Type : RCU-A-CB Outdoor Unit Brand Name : RUUD Outdoor Unit Model Number (Condenser or Single Package) : RA1630AJ1 Indoor Unit Model Number (Evaporator and/or Air Handler) : RH1T3617STAN Region : Region Note : • All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this RUUD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of A ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary r I f� t T f i t t t l rt It*i?+ Air Conditioning&_Air Source Heat Pump Equipment,and subject to rating acct" 1�racy by AHRI-sponsored `independent, third party testing: Cooling Capacity (A2) -Sin g e or Hi h Stage a 95F , btuh . 29000 4 I i J` SEER : 16.00 EER (A2} -Single or High Stage (95F) : 13.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced: copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTI FICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above. and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life Better'"' CERTIFICATE NO.: 1317114424182022 em RA -a Cabinetry Family-P d\WP\Orawings\15-2543 I - WProjects\15-2543 Rheem RA -a Cabinetry Family Ground -Mounted S RHEEM SALES COMPANY, INC. WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE -DOWN CLIPS: AT GRADE MOUNTED APPLICATIONS CONCRETE SUPPORTING STRUCTURE BY OTHERS, TYP. ANCHOR PER SCHEDULE 3000 PSI MIN. CONCRETE BY OTHERS, TYP. x r, x f SIM, 10 OUT ON OPP, i f,C.'E Z M CONCRETE SUPPORTING STRUCTURE BY OTHERS, TYP. FRONT ISOMETRIC 040 5 tAP }\�3S S<fNGTH A k EUm. TO ON OPP.'T.t_ CONTROL BOX MECHANICAL UNIT N.T.S. BACK ISOMETRIC THESE ISOMETRICS ARE INTENDED FOR DIAGRAMMATICAL PURPOSES ONLY; ALTERNATE RHEEM UNITS LISTED HEREIN MAY VARY IN APPEARANCE (2)-#10 SMS PER BRACKET, TYP. O&© ® & © ARE SIM AND OCCUR ON OPP. FACES TIE -DOWN BRACKETS N.T.S. ELEVATION ANCHOR SCHEDULE: O SUBSTRATE DESCRIPTION CONCRETE: (4" THICK MIN, 3000 PSI MIN.) (1)-1/4"0 STAINLESS STEEL ITW BUILDEX TAPCON, 13A" FULL EMBED TO CONCRETE, 2 Yr" MIN. EDGE DISTANCE, 3" MIN. SPACING TO ANY ADJACENT ANCHOR. INTERNAL POST ADJACENT TO CONTROL BOX UNIT BASE PAN CLI CLIP OFFSET DIMENSION SHALL BE TAKEN FROM THIS SIDE ONLY DIM. 1 —41.000" 1.250' 0.306 TYP. 0 °o 0.750" Y T1.000" TIE -DOWN BRACKET MIAMI TECH CLIP: 14GA (0.07") ASTM A653 Fu=90 KSI STEEL (CUTD8) OR 0.080" 5052-H32 ALUMINUM (CUTDAB), MIAMI TECH KIT # RRCUTDSMK OR RRCUTDASMK ±37.25" DATUM FACE a f ' j \ CONTROL `BOX jov-cup® TIE -DOWN BRACKET LAYOUT N.T.S. TIE -DOWN BRACKET OFFSETS: DIM. 1 4.50" MAX OFFSET FROM DATUM FACE DIM. 2 30.00" MIN OFFSET FROM DATUM FACE DIM. 3 31.00" MIN OFFSET FROM DATUM FACE DIM. 4 13.00" MAX OFFSET FROM DATUM FACE APPLICABLE MODELS: RA1360, RA1442A, RA1448,RA1460, RA1630, RA1636A, RP/UP2036, PLAN APPROVED DESIGN CRITERIA: ASCE 7-10 Vult=175 MPH (Vasd-136 MPH), EXPOSURE 'D', AT GRADE INSTALLATION ONLY DESIGN NOTES: THIS SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH ASCE 7-10 AND THE FLORIDA BUILDING CODE FIFTH EDITION (2014) FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. THE DESIGN CRITERIA CONSIDERS ASCE 7-10 SECTION 29.4.1 FOR "OTHER STRUCTURES - SOLID FREESTANDING WALLS" INSTALLATIONS AT GRADE. ALL DESIGN VARIABLES ARE IN ACCORDANCE WITH ASCE 7-10 CHAPTERS 26 & 29. GENERAL NOTES: 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) & ASCE 7-10. THIS SYSTEM MAY BE USED WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. THIS DESIGN IS NOT INTENDED TO CERTIFY IMPACT RESISTANCE OF THE MECHANICAL UNIT CABINETRY. 2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 3. DESIGN & CERTIFICATION OF THE UNIT CABINETRY IS APPROVED THROUGH TEST REPORT#0323.01-15 BY AMERICAN TEST LAB OF SOUTH FLORIDA. 4. ALL DIMENSIONS AND THE MINIMUM WEIGHT (200 LB MINIMUM) OF MECHANICAL UNIT SHALL CONFORM TO LIMITATIONS STATED HEREIN. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5. TAPCONS REFERRED TO HEREIN SHALL BE ITW BUILDEX BRAND, ASTM F593 410 STAINLESS STEEL OR EQUIVALENT ONLY, INSTALLED TO 3000 PSI MIN CONCRETE. SEE ANCHOR SCHEDULE FOR ANCHOR REQUIREMENTS. ALL SHEET METAL SCREWS USED TO FASTEN BRACKETS TO MECHANICAL UNITS SHALL BE #10 (14 MIN THREADS PER INCH) ASTM F593 410 STAINLESS STEEL OR EQUIVALENT ONLY. PROVIDE (5) PITCHES MINIMUM PAST THE THREAD PLANE FOR SHEET METAL SCREWS. ALL FASTENERS SHALL HAVE APPROPRIATE CORROSION PROTECTION TO PREVENT ELECTROLYSIS. 6. ALL CONCRETE SPECIFIED HEREIN IS NOT PART OF THIS CERTIFICATION. AS A MINIMUM, ALL CONCRETE SHALL BE STRUCTURAL CONCRETE 4" MIN. THICK AND SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI, UNLESS NOTED OTHERWISE. 7. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. B. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 9. THE ADEQUACY OF ANY EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS SHALL BE VERIFIED BY THE ONSITE DESIGN PROFESSIONAL AND IS NOT INCLUDED IN THIS CERTIFICATION.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 10. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 11. WATER -TIGHTNESS OF EXISTING HOST SUBSTRATE SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 12. FOR AN EXPLANATION OF EXPOSURE CATEGORIES THAT ACCOMPANY THE Vult WIND SPEEDS USED IN THIS DOCUMENT, SEE SECTION 26.7.3 OF ASCE 7-10. TROY S. BISHOP, P.E. NPE76131 06/10/2015 VALID FOR 1 PERMIT ONLY U.N.O y EIIMY'MTHORFMU FNGEFFRSV5 0 Qe Wln Win Z 0Q. WW N N m 410 ao U rf QaLL WU' rIO w FOLZR owl w� �a A FRANK L. BE RHEEM SALES COMPANY, INC. MECHANICAL UNIT STEEL TIE -DOWN CUPS 0 H x u Y rc t PB COPYRIGHT FRANK L BENNARDO P.E. 15-2543 SCALE: N.T.S. PAGE DESCRIPTION: 35" TALL UNITS 35.75' x 35.75' FOOT PRINT_ OF� °"Qu?'it=jHVACSolutions" 3921 SW 47th AvenueSuite 1003 Davie, FL 33314 P-954-761-2600 F-954-756-7510 info©astarairconditioning.com BILL TO: Kristy Johnson 357 NE 97th St. Miami Shores FL 33138 305-213-5328 QUOTE Date Quote Job Customer 5/18/2018 0000016717 0006605 LOCATION: Kristy Johnson 357 NE 97th St. Miami Shores FL 33138 P.O NUMBER TERMS SALES PERSON COD Qty. Item Description Price Each Amount 1.00 Work Description: Install Complete Central Air Conditioning 3,250.00 3,250.00 System. Installation kit Includes: 1) Cover work area with drop clothes. 2) Recover the old refrigerant and dispose if pressurized. 3) Remove old system and dispose. 4) Flush old oil from existing refrigerant lines. 5) Install new refrigerant filter drier. 6) Install condensate safety overflow switch. 7) Connect system to existing drain line and flush. 8) Connect system to existing ductwork and seal with sealant. 9) Connect to existing electrical disconnect and install proper fuses. 10) Connect to existing Thermostat* 11) Install outdoor unit on existing base with hurricane straps. 12) Install vibration pads under the units. 13) Evacuate the refrigerant lines and check for leaks. 14) Charge system with refrigerant, check operation. 15) Dispose of any garbage & thoroughly clean work space. 16) 1 Year standard labor warranty. 17) Manufacturer Parts Warranty Permit is not included unless is added to the quote in a separate line. 1.00 FPL Rebate discount -150.00 -150.00 1.00 AHSTAND 241N AH Stand 24" High 80.00 80.00 1.00 Permit or registration fees 320.00 320.00 Thank You for the opportunity to assist you with your project. We appreciate your business $3,500.00 TERMS & CONDITIONS: All work to be completed as written & detailed above, and according to existing state and local mechanical codes. Any changes due to known or unknown conditions, involving extra costs, will be executed upon the authorization of the party signing this contract and will become an extra charge over and above additional charge over the amount agreed. Goods and services delivered under this proposal will remain property of A Star AC Services until the all the amount is paid in full.. In Total amount has been paid. In the event of retumed payment, the seller (A Star Air conditioning) reserves the right to remove the goods delivered. If collection efforts are initiated against the purchas'r for nqp-payment, purchaser agrees to pay for all associated fees, attorney and court fees. Late payments: A 1.75% monthly interest will be a ed o mount owed. Authorizing Name: Authorizing Signature: 5/18/2018 Property Search Application - Miami -Dade County IMPORTANT MESSAGE When buying real estate property, you should not assume that property taxes will remain the same. Whenever there is a change in ownership, the assessed value of the property may reset to full market value, which could result in higher property taxes. Please use our Tax Estimator to approximate your new property taxes. The Property Appraiser does not send tax bills and does not set or collect taxes. Please visit the Tax Collector's website directly for additional information. Address Owner Name Folio SEARCH: 357 ne 97th Back to Search Results PROPERTY INFORMATION Folio: 11-3206-013-5750 Sub -Division: MIAMI SHORES SEC 1 AMD Property Address 357 NE 97 ST Miami Shores, FL 33138-2405 Owner JASON R ALDERMAN & KRISTY M JOHNSON (JTRS) Mailing Address 357 NE 97 ST MIAMI SHORES, FL 33138-2405 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ https://www.miamidade.gov/propertysearch/#/ 1/8