Loading...
RF-18-1631 i Perm t,N©. RF-6-18-163"1 `450 t, Miami Shores VillagePermit Type:ROOF c 10050 N.E.2nd Avenue NW 'Perl 11 "'t Work Classification:Flan Miami Shores,FL 33138-0000 Permit Status:APPROVED Phone: (305)795-2204 lORtD4' Issue Date:6114/2018 Expiration: 12/11/2018 Project Address Parcel Number Applicant 122 NW 110 Street 1121360030100 Miami Shores, FL 33168-4321 Block: Lot: KATE J&SEAN T ALBEE Owner Information Address Phone Cell KATE J&SEAN T ALBEE 122 NW 110 Street (561)827-9779 MIAMI SHORES FL 33168- 122 NW 110 Street MIAMI SHORES FL 33168- Contractor(s) Phone Cell Phone Valuation: $ 6,000.00 ACE PROPERTY SERVICES CORP 305-598-1700 Total Sq Feet: 469 Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF FRONT FLAT SMALL ROOF Inspection Type: Classification:Residential Tin Cap Scanning:3 Final Roof 1 Roof in Progress Renailing Affidavit Review Roof: Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $3.60 DBPR Fee Invoice# RF-6-18-67926 $3.75 06/14/2018 Check#:003840 $274.85 $0.00 DCA Fee $2.50 Education Surcharge $1.20 Permit Fee-New Roof $250.00 Scanning Fee $9.00 Technology Fee $4.80 Total: $274.85 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. I OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all w will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above-named contractor to do the work't June 14, 2018 Authorized Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy June 14,2018 1 f Miami Shores Village RECEID Building Department UN 14 ops 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 BY: Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 (� BUILDING Master Permit No--Lp o — 63 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [:] MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP / CONTRACTOR DRAWINGS JOB ADDRESS: l�/V W/I10 �T City: Miami Shores County:M•b Miami Dade Zin: �C Folio/Parcel#: il-_ Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder):1,60r ! /4 (-t-e-4L Phone#: JE�I X27• `1��7 Address: r 22-164 EKG' /(O -vi— City: / /��1-Nc 2311- State: Zip: 3316 Tenant/Lessee Name: Phone#: Email: (� CONTRACTOR:Company Name: Awe !-e(1/lCe"L Phone#: Address: to 8'1( S S -sr City: WL'14�,f State: Zip: Qualifier Name: co• -Cox Phone#: State Certification or Registration M CCC D Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: FF11��..® City: State: Ip: r�J/ Value of Work for this Permit:$ Q0U � �e7Wnear Footage of Work: IA60 (L44, Type of Work: ❑ Addition ❑ Alterationn -I ❑ New Repa' epla ❑ Demolition Description of Work:�� c t' S%W�C(/(� Specify color of color thru tile: Submittal Fee$ Permit Fee$mac)^-'t�� CCF$ CO/CC$ Scanning Fee$ Radon Fee$ z �y DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved a reinspec ion fee will be charged. A In Signature Signature 11V OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrment was acknowledged before me this 3 day of l(jj"� c�- 20 (_L,by 10 day of 20 1 ED, ,by A (P;)�o who is personally�known o i.;/�hAos PuiIes- who is personally known to me or who has produced lr(�� U�.e/�'�as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Si n: _ Sign: n:g Print: Print: Seal: ' '� '•%// ": MY COMMISSION#GC,p03711 Seal LIBERTAD VEGA-PULLES EXPIRES June 26.2020 MY COMMISSION 0 FF979011 y " PbrweN 00'" ,wit EXPIRES May 26,2020 •07 3ee.o�s3 **##*#*********#*##*************** **** **4s#>k**k#***k*#**#*** s* (407)398 tS **** k******k APPROVED BY k N1 I Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami-Dade County Page 1 of 1 ' OFFICE OF THE PRu'PERTY APPRAISER f _ Summary Report Generated On:6/14/2018 Property Informationr Folio: 11-2136-003-0100 Property Address: 122 NW 110 ST �. r Miami Shores,FL 33168-4321 t _ Owner KATE J ALBEE SEAN T ALBEE Mailing Address 122 NW 110 ST MIAMI SHORES,FL 33168 USA PA Primary Zone 0800 SGL FAMILY-1701-1900 SQ 0101 RESIDENTIAL-SINGLE Primary Land Use FAMILY: 1 UNIT '` Beds(Baths/Half 3/2/0 7 +.. _..�' Floors 1 . Living Units 1 y Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 1,863 Sq.Ft Taxable Value Information Lot Size 9,150 Sq.Ft 1 2018 2017 2016 Year Built 1938 County Exemption Value $50,000 $50,000 $50,000 Assessment Information Taxable Value 1 $262,784 $256,351 $250,050 Year 2018 2017 2016 School Board Land Value $196,886 $196,886 $164,440 Exemption Value $25,000 $25,000 $25,000 Building Value $132,907 $133,431 $133,955 Taxable Value $287,784 $281,351 $275,050 XF Value $1,613 $1,634 $1,655 City Market Value $331,406 $331,951 $300,050 Exemption Value $50,000 $50,000 $50,000 Assessed Value $312,784 $306,351 $300,050 Taxable Value $262,784 $256,351 $250,050 - Regional Benefits Information Exemption Value $50,000 $50,000 $50,000 Benefit Type 2018 2017 2016 Taxable Value $262,784 $256,351 $250,050 Save Our Homes Assessment Cap Reduction $18,622 $25,600 Sales Information Homestead Exemption $25,000 $25,000 $25,000 Previous OR Book- Price Qualification Description Second Homestead Exemption $25,000 $25,000 $25,000 Sale Page Note:Not all benefits are applicable to all Taxable Values(i.e.County, 09/24/2014 $420,000 29327-0001 Qual by exam of deed School Board,City, Regional). 01/30/2014 $220,000 29014-1373 Qual by exam of deed Financial inst or"In Lieu of 11/06/2009 $152,000 27079-2474 Short Legal Description Forclosure"stated MIAMI SHORES EXT PB 43-40 Financial inst or"In Lieu of LOT 10 BLK 219 02/13/2009 ` $100 26774-1238 Forclosure"stated LOT SIZE 75.000 X 122 OR 19131-4988 05 2000 4 COC 26165-3773 01 2008 3 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/propertysearch/ 6/14/2018 i • - t J h3 =- -v . . . . 7P gill � . . . . . . : : . : .: e1E;■� ':a:a': : :E l:■:■! !°;;�::::a:::AaI;E: on r■! a!! �i'a:! .■:�CCl.� aa'E ■ :� SEE .�■IaCC ::a:"�' . '. :�6a'a! L� ��rrrllr���i a� �� 0414141 ;:E :a e:EE�. . ■a. /�'; ■ :E:EE::' a ::a � r ,,.� . EE■: C.CEE:CE:l� X11- - - - - _.� �E .� �r - ■ aEa ■ as G ! R. �■� : �A "� Gat �� � �.:, ■■:' :■■ ':■ E■ ■■ ■ : a■ as a ii ■ : alit Qr ..� r�i :'�: r r ■ ■ !! !■ G�■ ! ■ ! ! r ■ !■ !a ■ Itr rnE ur ;sin i /■I• ■ ■f■•i iilYii ■r . Now G- DEPT IBLD3 DEPT i�J � ■ � ■ r • • • • , "� Il��fi�iiGl - • • UANCEWITHALLF • Section C °9��PNt•[]/�pE a Miami-Dade County HVHZ Electronic Roof Permit Form Section C Page(Low Slope Roof Systems) `anti s,Crit:.''=YrellertEt•�2'(_r}'t3.•ri.•, till in iho S exflc roc' ;�. l3 £i5SG!?3L'l_ .:Gli?l3Gft2 ts'.):r. �::r;rnGie2ii=!$?t7 �-r• ROOF SYSTEM MANUFACTURER: Polyglass USA Top Ply: n Product Approval (-OA): 17-1004.09 Acb �— (7 F Ie}� 5 i' i' System Type: Top Ply Fastening/Bonding Material: Wind Uplift Pressures,From RAS 128 or Sealed Calculations: Self adhered •••• (P1) Feld: -42.8 psf • • Surfacing: N/A � •.• ..•• ••.••• SINGLE PLY MEMBRANE: (P2) Perimeters: psf •• ' •••• • -71•� . . • • •••••• •• • • (P3)Comers: -108.0 Single Ply Manufacturer/Type: •••••. • • psf N/A •••• •••••• • • •••••- Maximum Design Pressure From NOA: -52.5 psf • •••• NIA • ••••• • • Single Ply Sheet Width: N/A "1/2 Sheet'1d�la '••• ••••• Roof Slo e: 025 12 •• •• '• P ":12 Roof Mean Height: ft. •••• ..•••• Parapet Walls: ❑No ®Yes Parapet wall Height:2 ft No.of Single Ply 1/2 sheets: N/A •••••• • •• • • • Single Ply Membrane Fastening/Bonding ••: Material: N/A :•••:• •••••• Deck Type: --5/8"Plywood-- ••• • • • Support Spacing: N/A o/c H FASTENER SPACING FOR BASESHEET ATTACHMENT• ❑ Alternate Deck Type: SINGLE PLY MEMBRANE ATTACHMENT Existing Roof. 1.Field: 8 "o/c @ Laps& 3 rows 8 "o% N/A Fire Barrier: 2.Perimeter: 6 "o/c @ Laps& 4 rows 6 "o/c N/A 3.Corner: 6 "o/c @ Laps&4 rows 6 "o/c Vapor Barrier: NUMBER OF FASTENERS PER INSULATION BOARD: N/A Anchor Sheet: 1. Field: N/A 2. Perimeter: N/A 3. Comer: N/A N/A Insulation Fastener Type Anchor Sheet Fastener/Bonding Material: N/A N/A WOOD NAILER TYPE AND SIZE: Insulation Base Layer Size&Thickness: N/A N/A Wood Nailer Fastener Type and Spacing: Insulation Base Layer Fastener/Bonding Material: N/A N/A EDGE&COPING METAL SIZES: Insulation Top Layer Size&Thickness: Edge Metalt'face erial:--Galvanized Metal-- N/A Insulation Top Layer Fastener/Bonding Material: Edge Size: 26 ga.-- N/A Hook Strip Size: --METAL EDGE HOOK STRIP N/A— Base Sheet(s)&No.of Ply(s): Edge Metal Attac men: ` 67L ii4-ST 9A Se 1 1/4"RS 4"OC Base Sheet Fastener/Bonding Material: Coping Material: --PARAPET COPING METAL N/A-- 1 1/4"RS&1 5/8"TC Ply Sheet(s)&No.of Ply(s): Coping Size: --COPING METAL SIZE N/A-- Elastoflex SA V Hook Strip Size: --COPING METAL HOOK STRIP N/A-2 Ply Sheet Fastener I Bonding Material: Parapet Coping Metal Attachment: Self adhered N/A Edge Nailable Deck MIAMMADE Miami-Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" 0000 0000 0000.. Illustrate Components Noted and Details as Applicable: •••;•• .' 0000.. .. 0000.. •.•.•• • 0000 :0000: • 0000.. 0000 . 0000. 0000.. 0000 0000 0000 0000 .00 0 0 0000.. • • • • • • : 0000.. 0000 Top Ply •'. • .. 'Do 0000.. Irderplies ' Base Sheet 4 ' Roof Mean Height: 12 ft. Drip Metal: 3x3, 26 ga, galy Surfacing: -- Drip Metal N/A Top Ply: Polyflex Sap FR r � a Interplies: k v Elastoflex SAV �a s Y Base Sheet: Roof Deck �, _ Elastobase ° Deck Type: Wood Parapet Wall Nailable Deck MIAMND E Miami-Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material•T,4ickness, Fastener Type, Fastener Spacing 00. 0 0.0 0• •• Or: Submit Manufacturers Details that Comply with RAS-111 and Chapter 16. '• •••• 000000 0 0000 :009:0 0 0000 Concrete wall 0 0 0 0 9:0 0000 • 0000. Elastomeric sealant tooled ..00 0 000 0% 00000 0000 r to facilitate water run-off 000000 00000 69 0000. -` Ontional:compressible 0 0 0••••• Elastomeric sealant 0 0004,00 :0069: Metal counterflashing mech. 00 --attached 8"o/c wl washer Parapet wall height: 2 ft. �-, fA Seal to of base flashing w/ 12 p g Roof Mean Height: ft. comptable material Base Flashing: Termination bar mech. modified granule attached 6"olc ` Surfacing: Field plies turned up wall N/A Top Ply: Base flashing min. Polyflex Sap FR 8"above finished roof Inter Ply Sheet: -- - Elastoflex SAV Top Ply Anterplies Base Sheet: a - ----Top "-� Elastobase Base Sheet Roof Deck Type: ,X-Roof Deck Wood a t v ' Miami Shores Village sell alit Building Department artment 10050 N.E.2nd Avenue �tpRlpP► Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ! ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE.00 0 •• BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES...... •;; •; •••; • PERSUANT TO SECTION 553.844 F.S. • Does • 00000 To: Miami Shores Village Building Department •D' 6�I `�� '�' ••:•• 10050 NE 2nd Ave ..•�„ e -..... Miami Shores, FI 33138 ' ' • Re: Owner's Name: " 4 ••••: 0 Property Address: t 2Z Nva j t o it .��,t' � t ( 3 3�rr --�• Roofing Permit Number: Dear Buildi certify that I am not required to retrofit the roof to wall connections of my building because: o- t e just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edit' o the So'lbith Florida Building Code(1994 SFBC) .Ag Print Name State of Florida County of Dade The undersigned, being the first duly sworn,deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 3 day of J 1 - ;?,�►*" LIBERTAD VEGA-PULLES fMY COMMISSION#FF979011 r Notary Public, Sate of Florida at Large,ge �.',�i*wM1Z EXPIRES May 26,2020 (407)398-0153 FloritlallotarySemice.com • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. 3!1�iDA SECTION 1524 HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the,evmer with the required roofing permit,and to explain to the owner the content of the section. The prq(tons of%ttion R440fe••• govern the minimum requirements and standards of the industry for roofing system inst`allatidns.AddlttmUly,the •, following items should be addressed as part of the agreement between the owner ant'tnecontractor'the 5wnerl* initial in the desi ed s ace indicates that the item has been explained. ••• • .... . ..... 2. •.�..� ..:..' Renailing wood decks:When replacing roofing,the existing wdod roof deck4ay have to...•• rn accordance with the current provisions of Section R4403. (Thd1161Mck is usually • concfledremoving the existing roof system). ' • ...... 4• sed Ceiling: Exposed,open beam ceilings are where the underside of the roof decking Icabem below. The owner may wish to maintain the architectural appearance;therefore, atiorj of the underside of the decking may not be acceptable.This provides the option of Aveeirload a ap•earance. 6• verflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is a buildup of water. Perimetededge wall or other roof extension may block this discr . erflow scuppers(wall outlets)are not provided. It may be ne essary to install overflow ppers in accordance with the requirements of Sections R4402, R440 nd R4413. Owner/Agents Signature Date Contrac ignature Date Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; �7 r,. IAMI'DADE =7 — _ MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) �e�r«.miamidade.eov/economy Polyglass USA,Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of copstrugtion materlq)s.The...... documentation submitted has been reviewed and accepted by Miami-Dade County RER-Prbdult Control bion to be .• used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiotim*EA.HJ).•.. ....:. This NOA shall not be valid after the expiration date stated below. The Miami-Dade County.Prodgct Colt;9L fiction• • (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the tfght to hdVe this ••;••. product or material tested for quality assurance purposes. If this product or material fails to 5e 59 in the accepted •"'• manner,the manufacturer will incur the expense of such testing and the AHJ may immediat 1 r ke, modi or •• P g Y �i Y.EYP �� .' suspend the use of such product or material within their jurisdiction. RER reserves the righCto fevbke this acceptance,...;. if it is determined by Miami-Dade County Product Control Section that this product or matefial fails to meet requirements of the applicable building code. •• • •• • • This product is approved as described herein,and has been designed to comply with the Florida Building 6dt• including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,-and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 13-1217.01 and consists of pages 1 through 34. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-1004.09 MIAMFDADE COUNTYM Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 1 of 34 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen i Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product* •••••• Product Dimensions Specification Description; ••;• • ...... .. . ...... Elastobase 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated Welglass reinTorced :....: Type I base sheet. ••���• �•••�• .... . ..... XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fvbgglass'rein(orced •• •• Base Type I base sheet. "" Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt-coated fiberglass r$intr4ed base sheet 6 6•*; Type II Polyanchor 250' x 48" ASTM D 4601 A polymer woven,high performance,synthe!ie base' Type II sheet. Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated, fiberglass reinforced, SBS (1.5-mm) Type] modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-Adhered,fire-rated, fiberglass reinforced, SBS PLUS FR Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V(1.5- 66' 8"x 3' 3_3/8" ASTM D 6163, Self-adhered,fiberglass reinforced, SBS modified mm) Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 33/s" ASTM D 6163, Self-adhered,fiberglass reinforced, SBS modified PLUS Type I bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered,fiberglass reinforced, SBS modified SA Type I bitumen membrane with a self-adhering back face and a smooth top surface. j Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back ' face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. jNOA No.: 17-1004.09 i MIAMNDADECOUNTY Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 2 of 34 Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. { XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APPemodified bitumen membrane with a tura eff polyetlrylene back-••:• face and a smooth or sanded'tbp gUrface.0 0:1. • •0•..0 •• • 000600 Polyflex G 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester rei>ifj4ced,APP mpdified 6 , I bitumen membrane with a bvm off polyethylene bac>to face and a granule top surface.•• ••.•• Polyflex SAP 32 10 x3' 3_ 00 /s ASTM D 6222 Self-adhered, of ester rei •d,APP cii�ied • 3 jpolyester �3�ig .gr ....•• Type I bitumen membrane with a self,-tering back face and . a granule top surface. • : 0 •...+• 0000.• Polyflex SA P FR 32' 10"x 3' 3 3/8" ASTM D 6222, Self-adhered,fire-rated,pOIZeste reinfo iced,APP ••• Type I modified bitumen membrane with a self*�kji ing back face and a granule top surface. XtraFlex APP G SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered,fiberglass reinforced, SBS modified Type 1 bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered,fire-rated,fiberglass reinforced, SBS FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. i Polyfresko G APP SA 32' 10"x 3' 3_3/81' ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 33/8" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type I base sheet. NOA No.: 17-1004.09 CDUNTY ADECOExpiration Date: 10/11/22 Approval Date: 10/12/17 Page 3 of 34 PG325 Cold Process 1, 3, 5, 50,55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. PG 100 Asphalt Primer 1,3, 5,50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz.spray selected asphalts used to promote adhesid$.* . . 6666 6666.. can ' .. 6666 • XtraFlex 10 Asphalt 1,3,5, 50,55 gal, ASTM D41 A penetrating solution of sokAmf and a blend of ... • • Primer tube or 17 oz. spray selected asphalts used to prmcte adhesion.• :6066: 0000 6 . • can 0.00•• •••• . 6666. PG350 Mod Bit 1,3, 5,50, 55 gal. or ASTM D3019 A fibered rubberized adhesi�dasigned fosuca with..:..' Adhesive tube Type III modified bitumen membraroas.•• •�•• •••••• PG400 Plastic Roof 1, 3, 5,50,55 gal. or ASTM D4586 A thick,fibered,rubberizeSNW` cement f0or use iii..„• Cement tube ASTM D3409 dry or damp conditions. 0 6 6666.. PG425 Wet/Dry Roof 1,3, 5,50,55 gal. or ASTM D4586 A thick,fibered,rubberized Mishing cerV81100r use ill Cement tube ASTM D3409 dry or damp conditions. 00 0 PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement. Cement tube PG500 MB Flashing 1,3,5, 50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1, 3, 5, 50, 55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. XtraFlex 35 Premium 1, 3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. Polyplus 45 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement. Flashing Cement tube Polyplus 50 Premium 1, 3, 5, 50, 55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. XtraFlex 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use Modified Wet/Dry tube with modified bitumen membranes. Cement Polyplus 55 Premium 1, 3, 5, 50,55 gal. or ASTM D4586 A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement NOA No.: 17-1004,09 MIAMI•DADECOUNTY Expiration Date: 10/11/22 ' Approval Date: 10/12/17 Page 4 of 34 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer . 0000.. •Iwiti� Current NOA) • Polytherm-H Polyisocyanurate foam insulation ••T"Iglass U3A,tnc. •••••' 0000.. Polytherm Polyisocyanurate foam insulation .P.Wyglass 1JSA.Inc. s ACFoam-II Polyisocyanurate foam insulation WL RooFing Corp ". 0000 0000 0000. ACFoam-III Polyisocyanurate foam insulation ..'Atllo..s Roofig Corp 0000 . j High Density Wood Fiberboard Wood fiber insulation board •: Generic . . . 0 000000 DensDeck,DensDeck Prime Gypsum insulation board Georgi&-Pacifio"Yoposum LI..C� • H-Shield Polyisocyanurate foam insulation �Iunter Pan0ISS9 • H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. i Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation NOA No.: 17-1004.09 MIAMMADECOUNTY Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 5 of 34 APPROVED FASTENERS: TABLE 3 Fastener Product Product . Mandwsuter ...... Number Name Description Dimensions ••4Wtth Current NOA) •, ...... .. : ...... 1. Dekfast Fasteners 12, 14& Insulation fastener for wood, •0 0*SFS Int*e* Inc. 15 HS steel and concrete decks 0900 • 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2'/s" x '•" SFS Ifltec,Inc. Hex Plate 3 1/411 .. .. .... ...... 3. #14 Roofgrip Insulation and membrane Various •••••• OMG, klc. • j fastener •• 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OA'014- ;••'• 5. Trufast#14 HD Fastener Insulation fastener for steel and Altenloh,Bthidk&Co. wood decks U.S.,Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co. Plate plate 3" round U.S., Inc. 7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various Polyglass USA, Inc &#15 steel and concrete decks 8. Polygrip Hex Plates Galvalume hex stress plate. 2'/a" x Polyglass USA, Inc 3 '/4" NOA No.: 17-1004.09 MIAMI•DADE COUNTY Expiration Date: 10/11/22 • Approval Date: 10/12/17 Page 6 of 34 APPROVED SURFACING: TABLE 4 0000 Product Product Application ••Alanufacter•••• Speificgtion • Name Description Rate ••" er ' PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1'/z-2 gal/sq *M740 •0 0 Polyglas 0 0 0 0 0000.. to add life and rejuvenate existing U,SA,Inc'0000. BUR roofing substrates. 00000• :0 0 0 0 0 ••••• XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used 1%2-2 gal/sq '1'Q500 0�10 . .•.Polyglas�000 • Coating to add life and rejuvenate existing *00000 VSA,Inc. 0• BUR roofing substrates. ' ' . . . . 0000.. 00.000 PG300 Fibered Roof Coating An asphalt cutback fibered roof 1%-2 gal/sq A$TK EL4479 0 Polyglass....: coating. May be applied by brush or 0 -0 OWJ A, Inc* •. . spray equipment to rejuvenate aged BUR XtraFlex Bituminous Roof An asphalt cutback fibered roof 1%-2 gal/sq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA, Inc. spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. %2-1 gal/sq ASTM D2824 Polyglass Roof Coating Type I USA,Inc. PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 1!/2-2 gal/sq ASTM D2824 Polyglass Coating Type III USA,Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1%i gal/sq ASTM D6083 Polyglass based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Emulsion Roof Coating emulsion two coats USA, Inc. XtraFlex 80 Emulsion Roof An asphalt base, un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Coating emulsion two coats USA, Inc. PG850 Fibered Asphalt Emulsion An asphalt base,fibered clay 3 gal/sq in ASTM D1227 Polyglass Roof Coating emulsion two coats USA, Inc. Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass Aluminum Roof Coating Type III USA, Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 Polyglass Coating Fibered Type III USA, Inc. } Polyplus 60 Premium Non- Non-fibered aluminum roof coating. %-1 gal/sq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA, Inc. XtraFlex 60 Aluminum Roof Non-fibered aluminum roof coating. ''/2-1 gal/sq ASTM D2824 Polyglass Coating Type I USA, Inc. MIAMI-DADE COU NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 7 of 34 APPROVED SURFACING: TABLE 4 Product Product Application .Manufactur S ecification• T-- Name Description Rate — 0'0 -so* er ••••;• i Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/z gal/sq ASTM ) 6083.::VbJyglass•• • Elastomeric Roof Coating based roof coating(water-based). A goes** iJ9A, Inc, • polyester fabric may be used for •••••• reinforcement with this coating. •••••• ••••• 0060* XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/z gal/sq ASYM*06083••:Volyglassso 00 • Roof Coating based roof coating(water-based). A •••••• ;USA,Inc. •• polyester fabric may be used for :**so:..... reinforcement with this coating. Polybrite 90 High Solids Silicone A premium grade high solids,single 1.25 gal/sq ASTM 136694.••4j 4yglass • Roof Coating component,moisture cure,fluid USA, Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids, single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component,moisture cure, fluid USA, Inc. applied silicone coating Polybrite 95 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA, Inc. XtraFlex SRC 8000 Silicone Roof A single component, solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA, Inc. f Gravel To be installed in a flood coat of 400 lbs/sq N/A Generic approved asphalt at 60 lbs/sq Slag To be installed in a flood coat of 300 lbs/sq N/A Generic approved asphalt at 60 lbs/sq NOA No.: 17-1004.09 MiAMMADECOUNTY Expiration Date: 10/11/22 ' Approval Date: 10/12/17 Page 8 of 34 EVIDENCE SUBMITTED: Test Azency Test Name/Report Report No. WLe 0000.. Factory Mutual Research 4470 2W7A7.AM •• 0$.Q4.94 .' Corporation 4450 2D5A9.AM 0 0 0 0. W2.D9 ...... 4470 3001334 ... •• 02.1.5.00 • 0000.. 4470 3000857 4470 3004091 •��� 01 0 •��•• •0000• •� 0000. 4470 3012321 07:.9.07 ...... 4450 3014751 0000.. 08.2-7.03 •� 4450 3019317 96.030!44 •••••• 000. 4470 3014692 •. 88.05.03 ;0000 Trinity ERD TAS 114 11752.09.99-1 02.009,00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-R1 02.27.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164/ASTM D6222 P10490.08.08 08.13.08 ASTM D6164/ASTM D6222 P10490.10.08-R1 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D)—ASTM D1876 P10070.10.08 10.09.08 ASTM D6222 P10490.10.08-2 10.30.08 FM 4470&TAS 114 P33970.03.11 03.15.11 ASTM D6163 /ASTM D 4601 P33960.03.11 03.15.11 TAS 114&TAS 117(B) 11757.12.00-1-R1 04.29.13 TAS 114&TAS 117(B) 11757.04.01-1-R1 04.30.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 /TAS 117 P45940.09.13 09.04.13 TAS 114&FM 4474 P41630.08.13 08.06.13 TAS 114(H) P13760.09.09 09.10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 NOA No.: 17-1004.09 MAMMADECO j Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 9 of 34 Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated 0*0 0 Deck Description: 19/3211 or greater plywood or wood plank,fastened at 24"spans with,8d cornmon name at 4"o.e.o 0•;• or#8 wood screws at 6"o.c. 6..9 ° 040:00 00000. j System Type E(1): Base sheet is mechanically attached to roof deck. 000*00 • 0000 0000.. All General and System Limitations apply. Roof accessories not listed in Table 1 of this9wo'k are not approved•;•y0 and shall not be installed unless said accessories demonstrate compliance with prescript to fjorida Bst'Mng ••••• Code requirements and are field fabricated utilizing the approved membranes listed irf Talfte 1. 4040 Base Sheet: One ply of Elastobase,XtraFlex SBS Glass Base, Elastobase P or lolyaVchor fiteri-to th-0 .s...• deck as described below: 000090 • Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 8" o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V(1.5-mm),Elastoflex SA V PLUS,XtraFlex SBS Base SA,Elastoflex SA V FR(1.5-mm)or Elastoflex SA V PLUS FR,self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR,Polyfresko G APP SA, Polyfresko G APP SA FR,Elastoflex SA P, Elastoflex SA P FR,XtraFlex SBS G SA, Polyflex SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP'G SA,self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf,(See General limitation#7.). NOA No.: 17-1004.09 �Ml"AMIA-D�Affiounm Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 26 of 34 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: • . . .... ...... 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Iatatetlals DAtVV for fire '. ratings of this product. ...... .. . ...... 2. Insulation may be installed in multiple layers. The first layer shall be attached in compllan ie with Frodyct ;•••• Control Approval guidelines. All other layers shall be adhered in a full mopping of aplypYed asphah•a6pop7ied ..... within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the f0 0 ing patter!:of the••:•• top layer0000 000000 3. All standard panel sizes are acceptable for mechanical attachment. When applied in IpplMd asphalt'panel size shall be 4'x 4'maximum. 000000 0000 4. An overlay and/or recovery board insulation panel is required on all application Over closed cell foam•••; insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall beoAmeiCd using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.;or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lbf. insulation attachment shall not be acceptable. j 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e. perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 17-1004.09 MIAMMADECOUNTY Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 34 of 34 .TGFU.R14571e Roofing,Systems 5/28118,8:14 PM L ONLINE CERTIFICATIONS DIRECTORY NOW AVAILABLE adLii+i4i�V.� TGFU.1114571 •••••• Roofing Systems •••••• • .... . ..... Paae Bottom •••••• •••• ••••• • Roofing Systems • . . . . ...... See General Information for Roofing Systems •..••• POLYGLASS USA INC R14571 1111 W Newport Center Dr Deerfield Beach, FL 33442 USA 4 SINGLE PLY MEMBRANE SYSTEMS Unless otherwise indicated,the insulation and base sheet are mechanically fastened in place; the membrane is heat welded in place. (Optional)Noncombustible roof deck classifications are applicable for use over combustible(15/32-in. minimum plywood) roof decks when minimum 1/2-in.thick gypsum board or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard", "DensDeck Prime@ Roofboard", "DensDeck DuraGuardT" Roofboard"or minimum 1/4-in.thick United States Gypsum Co. "SECUROCKT" Roof Board Type FRX-G" are used directly over the combustible roof decks with all joints staggered 6-in. (minimum)from plywood joints. Unless otherwise indicated, in any noncombustible roof deck Classification any UL Classified insulation may be utilized underneath a layer of minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard", "DensDeck Prime® Roofboard", "DensDeck DuraGuardT" Roofboard" or minimum 1/4-in, thick United States Gypsum Co. "SECUROCKT" Roof Board Type FRX-G". General statement for use of vapor retarders and/or deck/insulation adhesives noncombustible(NC)roof decks onlywhen such vapor retarders or deck/insulation adhesives are acceptable to POLYGLASS they may be utilized. "POLYGLASS BASE", "MODIBASE", "Polyglass G2 Base" may be used in lieu of any Type G2 base sheet in any NC Classification.These products may also be used in any combustible roof deck(minimum C-15/32)Classification in which a generic Type G2 is referenced (i.e. not brand specific). "POLYGLASS Ply 4", "POLYGLASS Ply 6"(Type Gl)", "POLYGLASS VENTED BASE", "XtraFlex Ply IV", "XtraFlex Ply VI"and "XtraFlex G2 Base" may be used in any NC Classification.These products may also be used in any minimum C-15/32 roof deck Classification in which a generic Type G1 is referenced (i.e. not brand specific). "BASE PRO"or"POLYFLEX SA BASE"may be used as an acceptable alternate of"ELASTOFLEX SA V" base sheet. References to polyisocyan u rate insulation may include Polyglass USA Inc, products"POLYTHERM@"and"POLYTHERM@ Tapered". Acceptable alternates to the membranes listed are given below: Membrane Listed Acceptable Alternatives "POLYSOND" "MODIBOND"or"Torch Pro Smooth" "POLYBOND G" "MODIBOND G"or"Torch Pro Granular" "ELASTOBASE" "Xtraflex SBS HT 650 Base"or"Polyglass HT Base 650" "ELASTOFLEX VG FR" "ELASTOFLEX VG HP FR"or"ELASTOFLEX VG FR (Type II)" "POLYFLEX G", "POLYFLEX COLD BOND", "Xreaflex APP G"or"Xtraflex APP "POLYFLEX G HP"or"POLYFLEX G (Type II)" G HP TOR" "ELASTOFLEX VG" "ELASTOFLEX V G HP"or"ELASTOFLEX V G(Type http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpa...d=1073741824&version=versionless&parent id=1073993597&sequence=1 Page 1 of 19 ,TGFU.R14571,-Roofing Systems 5/28/18,8:14 PM II)" "ELASTOFLEX S6", "ELASTOFLEX P-C"or"Xtraflex SBS Poly Base" "ELASTOFLEX S6 HP" or'ELSATOFLEX S6 (Type II)" "POLYFLEX G FR", "Xtraflex APP G FR"or"Xtraflex APP G HP" "POLYFLEX G HP FR"OR"POLYFLEX G(Type II) Membrane Listed Acceptable Alternatives "POLYFRESKO G FR' "POLYFRESKO G HP FR"or"POLYFRESKO 6 FR (Type II)" ••• •••• • •:�• "ELASTOFLEX S6 G FR", "XtraFlex SBS POLY G"or"XtraFlex SBS POLY G T" "ELASTOFLEX S6 G 1414 Flay or"ELAS1'OFLL'X S6 (Y 00** 1 FR(Type II)' •••••• • • • E r "POLYFRESKO G SBS FR" "POLYFRESKO G SB9iFRS or"PQL'/fRESKO G• •.. SBS FR(Type II') • • •••• • ••• "ELASTOFLEX S6 G", "ELASTOFLEX S6 G-C" "ELASTOFLEX S6 G HPt'dre"ELASTOPLM S6 G ' ••;• (Type II)" •••••• • •• "ELASTOFLEX SA V", "ELASTOFLEX SA V Plus", "ELSTOFLEX SA V BASE VENT" "ELASTOFLEX SA BA�E HDA ;•••'• • • or"Xtraflex SBS Base SA" • • • • "'• "Polytherm","Polytherm Tapered"or"Polytherm Composite" insulations may be used wherever polyisocyanurate insulations are specified in the Classifications below. Insulation may be optional for any non-combustible roof deck systems unless the insulation acts as a coverboard over another insulation. The"Cure Technology"finish may be added to any Polyglass USA Inc. membrane without adversely affecting the UL Classification for that product/assembly.The product/assembly would maintain the same Classification with or without the "Cure Technology" process. Unless otherwise indicated,"Ply IV"or"Ply VI" maybe used,in any Classification below that reference generic Type G1. Unless otherwise indicated, "G2 Base"may be used in any noncombustible roof deck Classification below that reference generic Type G2. "Polyflex Cold Bond" may be used as an acceptable alternate to "Polyflex G". MODIFED BITUMEN MEMBRANE SYSTEMS Class A-Ballasted 1. Deck: NC Incline: 3 Insulation:—Dyplast Products LLC"Pyrox White Line",glass fiber, perlite or wood fiber, any thickness. Membrane:—Any UL Classified PVC, mechanically fastened. Surfacing:—"Polybrite 95 Silicone"or"XtraFlex SRC 8000"series applied at 1-1/2 gal./100-ft2. 2: Deck: NC Incline: 1/2 Insulation: —Dyplast Products LLC"Pyrox White Line", glass fiber, perlite or wood fiber, any thickness. Membrane:—Any UL Classified hypalon, mechanically fastened. Surfacing:—"Polybrite 95 Silicone", "XtraFlex SRC 8000", "Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at 1- 1/2 gal./100-ft2. 1 Deck:C-15/32 Incline:3 Ply or Base Sheet:—One ply"Polyanchor", mechanically fastened. Insulation: —Polyisocyan u rate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite,glass fiber, phenolic or perlite, i any thickness. Ply or Base Sheet:—One ply"ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply","ELASTOFLEX V-C", "XtraFlex SBS G HP", "ELASTOSHIELD TS G","Elastoflex SA P Smooth", "Elastoflex SA Base HD" or "Elastoflex SA Base". Membrane:—One or more layers"DUFLEX", "DUFLEX G", "POLYGLASS 350 CAP", "POLYFRESKO 350 CAP", "POLYBOND", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G", "Xtraflex APP G", "XtraFlex APP G HP TOR"or"POLYFLEX G" (modified bitumen), heat I welded; or one or more layers"ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C", "ELASTOBASE", "XtraFlex SBS GLASS Base", "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C", "XtraFlex SBS G HP"or"ELASTOSHIELD TS G", hot mopped or heat fused. Surfacing:—Gravel,embedded in hot roofing asphalt. Class B-Ballasted 1. Deck:C-15/32 Incline:3 i http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpa...d=1073741824&version=versionless&parent id=1073993597&sequence=1 Page 2 of 19 TGFU.R14671-Roofing Systems 5/28/18,8:14 PM Base Sheet:—Type G2. Membrane:—"DUFLEX", "DUFLEX G","POLYBOND", "POLYGLASS 350 CAP", "POLYFRESKO 350 CAP", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G", "POLYFLEX G', "XtraFlex APP G HP TOR"or"Xtraflex APP G" (modified bitumen), heat; welded,or one or more layers"ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C", "ELASTOBASE", "XtraFlex SBS GLASS Base", ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C", "XtraFlex SBS G HP"or"ELASTOSHIELD TS G" hot mopped. Surfacing:—Gravel,embedded in hot roofing asphalt or heat fused. Class A-Fully Adhered 1.1 Deck: NC Incline: 1/2 ."••• . • 0060 6•••06 Insulation(Optional):—Polyisocyanurate, urethane, perl ite/polyisocyanu rate composite, perlite/urethanebcompq�":41pss fiber, 0• phenolic or perlite,any thickness. 000000 66 • 066.6• Base Sheet:—One or more layers"ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS&g$;;POLYFLEXi, "Xtraflex APP 9+, i "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C"or Type G2. """ Membrane:—"POLYBOND", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G", "Xtrafl*x*nAG", "XttaPle* APP G y�jpR or"POLYFLEX G"(modified bitumen), heat welded. so** ' 0 0 Surfacing:—"PG 800 Asphalt Emulsion Roof Coating", applied at 3 to 4-gal./100-ft2.; or Karnak Cord!:1e.237 Fibratad Murninum 0• Asphalt Roof Coating"or Karnak Corp. "No. 97 Asbestos Free Aluminum Roof Coating"at 1 to 2-gal./ltt-tV ; or Brewer Co "Fortress 5001 Asphalt Emulsion"applied at 4-gal./100-ft2.,followed by"PolyPlus 60",applied at 3/4 to 1-gal./10044!0:0: 0 o• • • 6 0 666666 2. Deck: C-15/3200000 6 60 Incline: 1/2 • • • 6••••• ' 6 : •i 66 6 • • Insulation:— Polyisocyanurate, perlite/po lyisocya n u rate composite, perlite/urethane composite, glass fiber, phenora,or perlite, any thickness,with insulation joints staggered a minimum of 6-in.from plywood joints. Base Sheet:—One or more layers"ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "POLYFLEX", "Xtraflex APP S", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C"or Type G2. Membrane:—"POLYBOND", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G", "Xtraflex APP G", "XtraFlex APP G HP TOR" or"POLYFLEX G"(modified bitumen), heat welded. Surfacing:—"PG 800 Asphalt Emulsion Roof Coating", applied at 3 to 4-gal./100-ft2.; or Karnak Corp. "No.97 Fibrated Aluminum Asphalt Roof Coating"or Karnak Corp. "No. 97 Asbestos Free Aluminum Roof Coating" applied at 1 to 2-gal./100-ft2; or Brewer Co "Fortress 5001 Asphalt Emulsion" applied at 4-gal./sq.,followed by"PolyPlus 60", applied at 3/4 to 1-gal./100-ft2. 3.'Deck: C-15/32/ Incline: 1/2 Insulation:—Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC"DensDeck® Roofboard"or"DensDeck Prime®Roofboard"or 1, "DensDeck DuraGuard'" Roofboard perlite,wood fiber or glass fiber,thick mechanically fastened. Base or ply Sheet:—One or more layers"POLYFLEX"or"Xtraflex APP S" (mechanically fastened or heat welded), "ELASTOBASE", i "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C"or Type G2, mechanically fastened or hot mopped. Membrane:— "POLYBOND", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G", "Xtraflex APP G", "XtraFlex APP G HP TOR" or"POLYFLEX G"(modified bitumen),heat welded or hot mopped. Surfacing:— "PG 800 Asphalt Emulsion Roof Coating"applied at 3 to 4-gal./100-ft2.; or Monsey Products"Endure Aluminum Roof Coating", "Weather Check"or"Pro-Grade Aluminum Roof Coating"applied at 1-1/2-gal./100-ft2; or Karnak Corp"No.97 Fibrated Aluminum Asphalt Roof Coating"or Karnak Corp"No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/100-ft2; or Brewer Co. "Fortress 5001 Asphalt Emulsion", applied at 4 gal./100-ft2.,followed by"PolyPlus 60", applied at 3/4 to 1-gal./100-ft.2. 4. Deck: NC Incline: 1 Insulation(Optional):—Polyisocyanurate,glass fiber, perlite,wood fiber, any combination,any thickness. Base Sheet:—"POLYFLEX" or"Xtraflex APP S", mechanically fastened or heat welded; or Type G2, mechanically fastened or hot mopped. Membrane:—"POLYBOND", "POLYBOND G", "POLYFLEX", "Xtraflex APP S", "POLYFRESKO G","Xtraflex APP G", "XtraFlex APP G HP TOR" or"POLYFLEX G"(modified bitumen), heat welded. Surfacing:—"PG 800 Asphalt Emulsion Roof Coating"applied at 3 to 4-gal./100-ft2.; or Grundy Industries"al MB Aluminum Roof Coating"applied at 1 to 2-gal./100-ft2.; or Brewer Co "Fortress 5001 Asphalt Emulsion", applied at 4-gal./100-ft2.,followed by"PolyPlus 60", applied at 3/4 to 1-gal./100-ft2. 5. Deck: NC Incline: 1 Insulation(Optional):—Polyisocyanurate, urethane, perlite/polyisocyanu rate composite, perlite/urethane composite,glass fiber, phenolic, perlite or wood fiberboard, any thickness. I Base Sheet:—One or more layers"DUFLEX"or"POLYFLEX"or"Xtraflex APP S"(heat fused or mechanically fastened), "ELASTOBASE", 4 "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C"or Type G2, hot mopped, heat fused or mechanically fastened. Membrane:— "DUFLEX G FR", "XtraFlex APP Dual","POLYFRESKO G FR", "Xtraflex APP G FR", "XtraFlex APP G HP"or"POLYFLEX G FR" (modified bitumen), heat fused. 6. Deck:C-15/32 Incline: 1/2 Base Sheet:—One or more layers"DUFLEX"or"POLYFLEX"or"Xtraflex APP S"or"POLYGLASS Base" (heat fused.or mechanically fastened), "ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C" or Type G2, hot mopped, heat fused or mechanically fastened. http://data base.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpa...d=1073741824&version=versionless&parent_id=1073993697&sequence=1 Page 3 of 19 TGFU.R14571-Roofing Systems 6113/18,9:38 PM r i Barrier Board:—Minimum 1/2 in. thick gypsum board or minimum 1/4 in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or DensDeck Prime@ Roofboard"or"DensDeck DuraGuardT" Roofboard"or minmum 1/4-in.thickUnited States Gypsum Co. "SECUROCKTM Roof Board Type FRX-G"are used directly over the combustible roof deck with all butt joints staggered a minimum of 6-in.from plywood roof deck joints. Base Sheet(Optional):—Type G2 Base sheet, mechanically fastened. Ply Sheet:— "Elastoflex SA V FR Base", (self-adhered). Membrane:—"Polykool SA R"or"Polyreflect", (self-adhered). 46. Deck: NC *fee Incline: 1/2 • • • • •••• •••••• ` Insulation (Optional):—Polyisocyanurate,glass fiber, perlite/polyisocyanurate composite, perlite/ur'&&an%-compAll a Vany thicknes9 Base Sheet:—One or more layers"DUFLEX", "Xtraflex APP S"or"POLYFLEX", heat fused or mechanieAlJ4f8stened*&on%or Mtre ••• layers"ELASTOBASE","Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtrafler4666 Glass InMrply"or-4gvg(A, hot mopped or mechanically fastened. •••• 0 0 0 • Ply Sheet(Optional):—One or more layers"DUFLEX", Xtraflex APP S"or"POLYFLEX" heat fused qr or moo?11y90es see*, "ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SB 5��asInterply'�.'f6ASTOF"** C"or Type G2,hot mopped or mechanically fastened. • • Membrane:—"Polyflex G FR"or"XtraFlex APP G HP",heat fused. •• •• •••• '•••;• 47. Deck: C-15/32 �••••� • •• 0008L / Incline: 1/2 • ••0-000 • • Insulation: — Polyisocyanurate(2-in.thick minimum lass fiber 15 16-in.thick minimum •080•• ), 9 ( / ), perlitel'ppj�lsc�yyanuratgcomposite� • perlite/urethane composite(2-in. thick minimum). • • • Barrier Board:—Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck Prime@ Roofboard"or "DensDeck DuraGuardT"Roofboard", United States Gypsum Co. "SECUROCK@ Glass-Mat Roof Board"(Type SGMRX), National Gypsum "DEXcell Glass Mat Roof Board"or"DEXcell FV Glass Mat Roof Board"mechanically fastened with all butt joints staggered a minimum of 6- in. from the plywood roof deck joints. Base Sheet:—"ELASTOFLEX S6", "XtraFlex SBS POLY Base" "ELASTOFLEX P-C"(heat fused or mechanically fastened). Ply Sheet:—"ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" (heat fused or mechanically fastened). Membrane:—"ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C FR"or"POLYFRESKO G SBS FR", (heat fused). 48. Deck: NC Incline: 1 Insulation(Optional):—Polyisocyanurate, perlite,wood fiber or polyisocyanurate/perlite board, any thickness. Base Sheet:—"ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), mechanically fastened or"Polyflex SA Base", "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or"ELASTOFLEX SA V FR BASE VENT"(self-adhered) Ply Sheet(Optional):— "ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), heat fused or mechanically fastened, or"ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT", (self-adhered). Membrane:— "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR","ELASTOFLEX SA V FR HT", (self-adhered)or"POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR","DUFLEX G FR", "XtraFlex APP Dual", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T" "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or"ELASTOSHIELD TS G FR", heat fused. 49. Deck: C-15/32 Incline•2 Insulation(Optional):—Polyisocyanurate, perlite,wood fiber or polyisocyanurate/periite board, any thickness. Base Sheet:—"ELASTOBASE"or"Elastobase Vented Base", mechanically fastened; or"ELASTOFLEX SA V FR",self-adhered. Ply Sheet(Optional):— "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT",self-adhered. Membrane:— "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR"or"POLYFRESKO G SBS SA P FR",self- adhered; or"DUFLEX G FR", "XtraFlex APP Dual", "POLYFLEX G FR "XtraFlex APP G HP% "Xtraflex APP G FR", "ELASTOFLEX S6 G FR "POLYFRESKO G SBS'FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T", "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT"or"ELASTOSHIELD TS G FR", heat fused. 50` Deck: NC Incline: 1/2 Insulation:—Polyisocyanurate(2 in. thick minimum),glass fiber(15/16 in. thick minimum),perl ite/polyisocya n u rate composite, perlite/urethane composite (2 in. min). Barrier Board (optional):—1/4 in. (min)G-P Gypsum DensDeck@, mechanically fastened. Base Sheet:—"ELASTOFLEX V", "ELASTOSHIELD HT", "ELASTOSHIELD TS", "ELASTOFLEX S6" "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" (heat fused or mechanically fastened). Membrane:—"ELASTOFLEX V G", ELASTOFLEX V G FR", "ELASTOFLEX S6 G", "ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C"or POLYFRESKO G SBS", (heat fused). 51. Deck: C-15/32 Incline: 1/2 Insulation:—Polyisocyanurate(2 in. thick minimum),glass fiber(15/16 in.thick minimum),perlite/polyisocya nu rate composite, perlite/urethane composite(2 in. min).Mechanically attached, hot asphalt adhered or foam adhered. Barrier Board:— 1/4 in. (min)G-P Gypsum DensDeck@, DensDeck Prime@,or SECURock hot asphalt adhered or foam adhered. Base Sheet:—"ELASTOFLEX V", "ELASTOSHIELD HT" ,"ELASTOSHIELD TS", "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" hot mopped or torch applied. Membrane:—"ELASTOFLEX V G", ELASTOFLEX V G FR", "ELASTOSHIELD TS G FR", "ELASTOFLEX S6 G","ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C"or"POLYFRESKO G SBS", (heat fused). http:J/database.ul.com/cgi-bin/XYWtemplate/LISEXT/1FRAME/showpa...d=1073741824&version=versionless&parent id=1073993597&sequence=1 Page 9 of 19