REV-16-2004 CAM ENGINEERING LLC — Consulting Engineers, MEP
;t! 5520 SW 96 Avenue,Miami Fl. 33165 - Tel: (305)484 7276 E-mail: caumera@aol.com
t
ALMEIDA-BARRANTES RESIDENCE
RESPONSE TO BLDG. DEPARTMENT COMMENTS DATED 8/2/16
Electrical comments made by: Michael Devaney }
1. COMMENT r
RECEPTACLES REQUIRED FOR TERRACE LOCATED WITHIN THE PERIMETER OF THE
TERRACE. NEC 210.52 (E) (3).
RESPONSE: RECEPTACLES ALREADY PROVIDED. PLEASE RE-VISIT THE SUBMITTED PLAN,
SHEET E-2
2. COMMENT
IF THAT IS A COUNTERTOP WHERE THE WINE COOLER IS GOING,THE COUNTERTOP
RECEPTACLES ARE REQUIRED AS PER NEC 210.52 (C).
RESPONSE: WINE COOLER LOCATION IS NOT A COUNTERTOP.
3. COMMENT
PLEASE MAKE CORRECTION FOR PANEL A SCHEDULE WHERE IT STATES FED FROM: 175
A. MAIN. IT IS NOW 150 A. MAIN.
RESPONSE: PANEL SCHEDULE WAS REVISED TO INDICATE 150 A. FEEDER BREAKER.
REFER TO REVISED SHEET E-3. +
a
Respectfully submitted.
Cesar A. Mera;PE, D A
Electrical Engineer `
FL.License#62175
Tel 305-4847276
r
t
5520 SW 96 Avenue,Miami Fl. 33165 - Tel: (305)484 7276 - E-mail: caumera@,aol.com
i
.N ONEDB arch itecture+design
July 14, 2016
Miami Shores Village
Building Department
f
RE: Permit plans for:
Residence at
9879 NE 13th Avenue
Miami Shores, FI
i
1. Modification to Bathroom Shower instead of tub.
2. Reflecting Ceiling was changed on Living Room.
3._Ceiling Detail was updated (See A-1)
a 4. Concrete Slabs with Paver insert instead of Pavers with Turf inlay.(See A-1) r
5. Closet and Stairs where eliminated at Service Corridor (See A-1)
y I
JO
P i ` ipal One Design build LLC.
f
i
5582 NE 4" Ct Suite 7A Miami FI 33137-ph.786-8591143 Onedbmiami.com
t
US STRUCTURAL DESIGN LLC
CONSULTING ENGINEERS
7850 NW 146 Street, Suite 305, Miami Lakes,FL 33016
T. 305.512.5860 F. 305.512.5861
www.ontimussd.com
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALMEIDA - BARRANTES RESIDENCE
REVISION NARRATIVE
7 7 ,
S
hMillr +.T
LOCATED AT:
9879 NE 13th AVENUE
MIAMI SHORES, FL 33138
t o6
Tanya Homleid P.E.
e ,x, PE#61706
June 2"`',2016
r
US STRUCTURAL DESIGN LLC
CONSULTING ENGINEERS
7850 NW 146 Street, Suite 305, Miami Lakes, FL 33016
T. 305.512.5860 F. 305.512.5861
www.ontimussd.com
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
August 29`h,2015
City of Miami Shores
Building Department
STRUCTURAL REVISION 43 NARRATIVE:
The following is a brief description of items that were changed in revision#1:
ITEM No. RESPONSE
Eliminate two steel columns inside and west of the terrace, per revisions to
S-1.0 sheets S-2.0 and S-5.0. Revise steps up from garage as a delegated design
item.
Replace 2x12 ceiling ridge beam with (2)2x10 wood straps fastened at
S-2.0 existing joists to maintain a clear space. See attached supplemental
calculations and revised detail sheet S-5.0
S-3.0 Revise sheet to eliminate duplicate helical pile detail on the lower right
corner of sheet.
Revise sheet to replace wood beam and steel detail with (2) 2x10 strap to
S-5.0 retrofit existing joists. The wood strap shall be added See attached
calculations.
Please let us know if you have any further questions or require additional information.
Best Regards,
SIGNED:
Ian Ho leid, P.E.
REG. NO. STATE: FL. 61706
COMPANY: Optimus Structural Design LLC
ADDRESS: 7850 NW 146 Street, Suite 305
Miami Lakes, Florida 33016
S.I. NO: # 7021292
Company June 1,2016
Designer 5:10 PM
Job Number Checked By:
Global
Display Sections for Member Calcs 5
Max.dnternal Sections for'Member:Calcs 97
Include Shear Deformation? Yes
Mere Tolerance in 1"2
P-Delta Analysis Tolerance 0.50%
Include�P=Delta=for.Walls? Yes
Automaticly Iterate Stiffness for Walls? Yes
Maximum lteration'Number.for.Wall Stiffne s3.
Gravity Acceleration ft/sec^2 32.2
Wall Mesh"Size-(in)- 12 .
Ei ensolution Convergence Tol. 1.E- 4
D namic Solver Accelerated;Solver
Hot Rolled Steel Code RISC 14th 360-10 : ASD
Ad'ust;Stiffness? - Yes Iterative
RISAConnection Code None
Cold Formed'Steel'Code AISI S1'00-10:rASD
Wood Code AF&PA NDS-12: ASD
Wood Temperature <'1OOF
Concrete Code ACI 318-11
Mason ,,Code AC1 530-10:ASD
Aluminum Code AA ADM1-10: ASD - Building
Number of Shear Regions 4
Re ion S acin Increment in 4 .
Concrete Stress Block Rectangular
Use CrackedSections?_ Yes
Bad Framing Warnings? No
Unused Force Warnin s?' Yes
Min 1 Bar Diam. Spacing? No
Concrete Rebar Set REBAR SET ASTMA615
Min % Steel for Column 1
Max % Steel-for'.Column 8
Wood Material Properties
Label TVDe Database S eies Grade m Emod Nu Therm \...Dens k/ft^3
1 DF Solid Sawn Visually Gr.. Douglas Fir-Larch No.1 1 .3 .3 .035
2 ;SP Solid Sawn Visually Gr..j Southern Pine 'No i1 1 :3 :3 .035
3 HF Solid Sawn Visually Gr.. Hem-Fir No.1 1 .3 .3 .035
4 SPF Solid Sawn'Visually Gr.. °S ruce-Pine-fir No;1 1 3 .3 .035
5 24F-1.8E DF B. Glulam Table 5A 24F-1.8E_DF_BAL na 1 .3 .3 .035
6 24F-1..8E DF.U.. Glulam Table'SA 241`71.8E_DF .UNB.. na 1 .3 3 .035
7 24F-1.8E SP B.. Glulam Table 5A 24F-1.8E_SP_BAL na 1 .3 .3 .035
8 :24F-1,8E'SP U., .Glulam Table5A 24F-1l8E_SP UNB.. na
.:.. 3 3 -035
Wood Section Sets
Label Shape TVDe Desi n List Material Desi n Rules A int 190 270 i... 1 (0,180in
f 1 WOOD1A 2X6 Beam Rectan ular DF T ical 8.25 1.547 20.797
Member Primary Data
Label I Joint J Joint Rotate de Section/Shape Type Desian List Material Desian Rules
1 M1 N1 N3 2X10 Beam None I SP T ical
2 M2 N3 N2 2X10 Beam I None I SP Typical-
3
ical3 M4 N5 N6 2-4X10B Beam I Rectangular I DF Typical
RISA-21D Version 12.0.0 [Z:\...\...\Barrantes-Residence\Calcs\ROOF FRAME-alt.r2d] Page 1
Company June 1,2016
Designer 5:10 PM
Job Number Checked By:
Member Advanced Data
Label I Release J Release I Off set[inl J Offset in T/C Only Physical TOM inactive
1 M1Yes
` Yes
3 M4 Yes
Member Detailing Data
Label I Cardinal Point I x Offset�inlOffset in�Izset in J Cardinal Point J x Off i J Offset in J z Offset in
1 M1 8 0 .625 8 0 2 "M2 g 0 :625 8 0 4'625 ':0
3 M4 8 0 1 2.75 1 0 1 8 1 0 1 2.75 10
Joint Coordinates and Temperatures
Label X f Y[fti Temp F
1 N1 0 0 0
2 ~N2 31.65 '0 0.
3 N3 15.825 3.33 0
4' N5 -1'0.552083 -2:223958 - 0
5 N6 21.098958 2.223958 0
Joint Boundary Conditions
Joint Label Xk/in Y k/in Rotation k-ft/rad Footing
1 N1 Reaction Reaction
2
2N2 'Reaction'
_ Wood Design Parameters
Label ShaDe Len th ft Le-out ft Le-in ft le-bend to... le-bend bo... K-out K-in CV Out swa In sway
1 M1 2X10 16.172 1.33 1.33 1.33 1.3 -Cres
2 M2 :2X10 16°:172 = 11.33 '1.33 °1.33 1:33 Yes
3 M4 2-4X106 10.547
Design Size and Code Check Parameters
Label Max De th in Min De th in Max Width in Min Width in Max Bendin Chk Max Shear Chk
1 T ical 1 1 1
Joint Loads and Enforced Displacements (BLC 3 : WIND)
Joint Label L D M Direction Ma nitude k k-ft in rad k*s^2/ft...
1 N2 L X .264
Member Distributed Loads (BLC 1 • DEAD)
Member Label Direction Start Ma nitude k/f F End Ma nitude k/f F S art Loca ion ft°/ End Location ft%
1
M1 V -.06 -.06 0 0
2 M2 V -.06 -.06 0 0
Member Distributed Loads (BLC 2 : LIVE)
Member Label Direction Start Ma nitude k/ft F End Ma nitude k/ft.Fl Start Location ft% End Location ft
1 M1 V -.039 -.039 0 0
2 M2 V -.039 -.039 0 0
RISA-2D Version 12.0.0 [Z:\...\...\Barrantes-Residence\Calcs\ROOF FRAME-alt.r2d] Page 2
Company June 1,2016
Designer 5:10 PM
Job Number Checked By:
Member Distributed Loads (BLC 3 : WIND)
Member Label Direction Start Ma n'tud k/f FEnd Maanitudefk/ft.Fl Start Locationrft.%l End Loca ion ft%
1 M1 V 057 .057 0 0
"2 'M2 V ;057 :057 ro
Basic Load Cases
BLC Description Cate o X Gravitv Y Gravity Joint Point Distributed
1 DEAD DL -1 2
J2 < : lIVE LL
3 WIND WL 1 11 2
Load Combinations
Description SolvePD... SR... BLC Factor BLC Fac or BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor
1 0.6DL-WL IYes I I I DL 1 .6 1 WL 1 1
Load Combination Design
Description ASIF CD ABIF Service Hot Rolled Cold Form... Wood Concrete MasonU Footings Aluminum
1 1 0.6DL-WL Yes Yes I Yes Yes Yes Yes Yes
Joint Deflections
LC Joint Label X rinl Y finl Rotation rad
1 1 N 1 0 0 6.819e-3
'2 '1` "N2 0
Company June 1,2016
Designer 5:10 PM
Job Number Checked By:
Member Section Forces (By Combination) (Continued)
LC Member Label Sec Axial[k] Shear[k] Momentfk-ftl
�5
`;10 _ _
11 1 M4 1 .337 .05 .708
12 337 1025 :609
2
13 3 .337 0 .576
,14. 4, '337 -:025 .609
15 5 .337 -.05 .708
Member Section Stresses
LC Member Label Sec Axial ksi Shear[ksil Top Bendinark ndinalksil
1 1 Ml 1 .022 -.021 0 0
2 2 -.021 --:013 -.348 . 348
3 3 -.02 -.005 -.53 .53
4 4 -.044 '005 : -:133 ;':1`33
5 5 -.042 .013 .065 -.065
,'6 ; . .1 -'M2 _1 -:042' --:013 :065
7 2 -.044 -.005 -.133 .133
8 ' . 3 -:02 005 -:53 53
g 4 -.021 .013 -.348 .348
`1.0 5 -.'022 021 0 0
11 1 M4 1 .005 .001 -.085 .085
,12.
'2 005 0 -.073 `'073
13 3 .005 0 -.069 .069
1.4 4 .0050 .: -:073= .073
15 5 .005 -.001 -.085 .085
Member Section Deflections
I r Member Label Sec x finlin n L/y Ratio
1 1 M1 1 0 0 NC
2 2 p 31.2 1178:91`5
3 3 .001 .524 846.743
4 -4 .002 °588 1332:631
5 5 .003 .589 NC
6 1 M2 1 _:235 .541 NC
7 2 -.233 .539 1332.846
'8 3 -:233 .475.: 846.82
g 4 -.232 .263 , 1178.986
1.0 ,5 -:23'1 -.049 NC
11 1 M4 1 -.118 .569 NC
12 2 -:1`1'8 .582 9129.688
13 3 -.118 .587 6909.81
14 4 11:8 .582 9129:519
15 5 -.118 .569 NC
Member Wood Code Checks
LC Member Shape UC Max Lo ft Shear... Loc f Fc'rksil Ft'ksi Fb'ksi M-41 RB CL CP E n
1 1 M1 2X10 .401 10.444 .117 0 1.46 .725 1.484 .175 8.008 .993 .913 33j;:99
-1
2 1 M2 2X10 401 .5:727 117 16.172 1.46 725 1:484-- .175 8.1- 993 913 -1
3 1 M4 2-4X108 .071 10.547 .006 10.547 .793 .743 1.198 .18 4.888 .998 .529 9-3
RISA-2D Version 12.0.0 [Z:\...\...\Barrantes-Residence\Calcs\ROOF FRAME-alt.r2d] Page 4
i 1
• Company June 1,2016
Designer 5:10 PM
Job Number Checked By:
Wood Wall Panel Parameters
Label Top Pla a Sill Plate Studs Min Stud Sp— Max Stud S ...Green Lum .. Header Size Header Matl
1 Typical I 2-2X6 2X6 2X6 16 16 6x8 Same as Wall
Additional Wood Wall Panel Parameters
Label Schedule Min. Panel...Max. Pa e.-Double Sid..Max. Nail... Min. Nail S...HD Chords HD Chord .. Hold Down
1 T ical IBC06-09 Pane.. .375 .75 O timum 6-in. 3-in. 2-2X6 Same as... ISIMP HDA Dat...
Wood Wall Panel Axial Code Checks (AF&PA NDS-12: ASD)
Wall Panel Region Stud Size Stud S aci... Axial Check Gov LC Chord Size Chord Axi I Ch... Gov LC
No Data to Print ...
Wood Wall Panel In Plane Code Checks (AF&PA NDS-12: ASD)
Wall Panel Shear Panel Label Re ion Shear Check Shear Forc... Gov LC Hold-Down ...Tension Qh...Tie-Dow... Gov LC
No Data to Print ...
4
RISA-2D Version 12.0.0 [Z:\...\...\Barrantes-Residence\Calcs\ROOF FRAME-alt.r2d] Page 5
y
i
t
fi
a RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
k 1
Florida Department of Business and'Professional Regulation
Simulated Performance Alternative(Performance)Method
4
Applications for compliance with the 2010 Florida Building Code, Energy Conservation via the
residential Simulated Performance method should include
M' Form 405(usually 5 pages/may be greater)
C� Energy Performance Level(EPL)Display Card(one page)
Required prior to CO for Hie Performance Method:
W K duct leakage has been tested then.a completed Air Distribution System Test Report
(usually one page)
❑ A completed Envelope Leakage Test Reponyusually one page).
f
v
i
k
y.
I '
EnergyGauge®-USRCSB v4.0
_ r \
1
FORM 405-10 i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Remodeling at 9879 NE Rev Builder Name:
Street: 9879 NE 13th Avenue Permit Office:
City',-State,Zip: Miami Shores,FL,33138- Permit Number:
Owner: Almeida Barrantes Jurisdiction: 231000
Design Location: FL,Miami
1. New construction or existing Addition 9. Wall Types(3405.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2928.30 ft2
b. Interior Frame-Wood,Interior R=4.1 261.38 ft2
3. Number of units;if multiple family 1 c.Concrete Block-Int Insul,Adjacent R=4.1 216.04 ft2
4. Number of Bedrooms(Sedrms In Addition) 5(2) d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (3738.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 3738.00 ft2
6. Conditioned floor area above grade(ft2) 3738 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts I R ft2
7. Windows(804.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 150
a._U-Factor. Dbl,U=0.65 804.47 ft2 b.Sup: Attic,Ret:Bedrooms,AH:Bedrooms 6 270
SHGC: SHGC=0.30
b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 36.0 SEER:16.00
b.Central Unit 60.0 SEER:16.00
c. U-Factor: N/A ft2 a
SHGC: 13.Heating systems kBtu/hr Efficiency
ii. U-Factor: N/A ft2 a.Electric Strip Neat 24.6 COP:1.00
SHGC: b.Electric Strip Heat 34.1 COP:1:00
Area Weighted Average Overhang Depth: 5.302 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems-Supplemental for addition`
8. Floor Types (3738.0 sqft.) Insulation Area a.Electric I Cap:80 gallons
a.Crawlspace R=0.0 3738.00 ft2 b. Conservation features EF:2.300
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 86.08 PASS
Glass/Floor Area: 0.215 Total Standard Reference Loads: 110.61 1r-
I hereby certify that the plans and specifications covered by Review of the plans and 0V-VHE ST,���
this calculation are in compliance with the Florida Energy specifications covered by this
f� r
Code. calculation indicates compliance
PREPARED Y' S�f�__� fc%zF / with the Florida Energy Code.
^�f 4
r _ Before construction is completed ""
DATE: l `G__ this'building will be inspected for
/ compliance with Section 553.908 C �
1 hereby certify that this building,-as designed, is in compliance" Florida Statutes.
-
with the Florida Energy Code. G'prj WF
OWNER/AGENT:____._.__ _ _ BUILDING OFFICIAL: } _
DATE: _ _ _ --- -- -« DATE:
i
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
i
7%1/2016 1:53 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
E r
PROJECT
Title: Remodeling at 9879 NE Rev Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 3738 Lot#
Owner: Almeida Barrantes Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case. No PlatBook:
Builder Name: Rotate Angle: 0 Street: 9879 NE 13th Avenue
Permit Office: Cross Ventilation: County: Miami-Dade
Jurisdiction: 231000 Whole House Fan: City,State,Zip: Miami Shores,
Family Type: Single-family FL. 33138-
New/Existing: Addition
Comment:
- CLIMATE
IECC` Design Temp Int Design Temp Heatingy Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Miami -__FL_MIAMI_INTL_APlM 1� � 51 "�-90 70 75 �- 149.5 z --�~5t _ Low
BLOCKS
Number' Name Area Volume
1 Blockl 1353 12177
12 Block2 2385 21465
SPACES
Number Name Area Y_ Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
11 Main 1353 12177 Yes 6 1 1 Yes Yes Yes
2 Bedrooms 2385 21465 No 5 4 1 Yes Yes Yes
t
FLOORS t
y# Floor Type + Space_ Perimeter Perimeter R-Value Area Jois_t_R-VaI_u_e Tile Wood Carpet
v11 Crawlspace Main 167.66 ft 0 1353 ftZ '^— 0 0 1 0
2 Crawlspace Bedrooms r 265.66 It 0 2385 ft2 0 0 1 0
ROOF,
/ Roof Gable Roof Solar, SA Emitt Emitt Deck Pitch,
# Type Materials Area Area Color• Absor. Tested Tested Insul_ (deg)
1 Hip Flat tile/slate 3939 W 0 ftz Medium 0.72 No 0.9 No 0 18.4
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
__4,/_ 1 Full attic Vented 300 ~�s 3738 ftz�~ N N _ 4
i
7/1/2016 1:53 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software �F Page 2 of 6
t
CEILING {
# Ceiling Type Space R-Value Area Fram;ng Frac Truss Type
J 1 'Under Attic(Vented) Main 30 1353 ft2 0.11 Wood.
2 Under Attic(Vented) Bedrooms 30 2385 ft2 0.11 Wood
WALLS
/ Adjacent Space Cavity Width Height Sheathing Framing Solar Below
#__Ornt-- To_.-WallType.__�_.__ -_R-Value_.Ft__-In.--__Ft--In_.-�-Area-____R-Value__Fraction._.Absoc_Grade%.�
1 S Exterior Concrete Block-int InsulBedrooms4.0999 94 8 8 6 804.7 W 0 0.75 0
2 E Exterior Concrete Block-Int InsulBedrooms 4.0999 18 3 8 6 155.1 ft2 F 0 0.75 0
3 N Exterior Concrete Block-Int InsulBedrooms 4.0999 13 11 8 6 118.3 ft2 0 0.75 0
J 4 N Exterior Concrete Block-Int InsulBedrooms 4.0999 42 9 8 6 363.4 ft2 0 0.75 0
+/ 5 N Exterior Concrete Block-Int InsulBedrooms 4.0999 6 8 6 51.0 ft2 0 -0.75 0
6 W Exterior Concrete Block-Int InsulBedrooms 4.0999 18 9 8 6 159.4 ft2 0 0.75 0
f
7 E Exterior Concrete Block-Int InsulBedrooms 4.0999 20 8 6 170.0 ft2 0' 0.75, 0
V 8 E Exterior Concrete Block-Int Insul Main 4.0999 12 1 8 6 102.7 ft2 0 0.75 0
9 S Exterior Concrete Block Int Insul Main 4.0999 4 4 8 6 36.8 ft2 0 0.75 0
10 E Exterior Concrete Block-Int Insul Main 4.0999 12 7 8 6 107.0 ft2 0 0.75 0
11 N Exterior Concrete Block-Int Insul Main 4.0999 56 5 8 6 479.5 ft2 0 0.75 0
12 S Exterior Concrete Block-Int Insul Main 4.0999 13 11 8 6 118.3 ft2 1 0 0.75 0
•✓ 13 S Exterior Concrete Block-Int Insul Main 4.0999 5 11 8 6 50.3 ft2 0 0.75 0 t
j 14 W Exterior Concrete Block-Int InsulBedrooms 4.0999 19 6 8 6 165.8 ft2 0 0.75 0 k
15 N Garage Concrete Block-Int Insul Main 4.0999 25 5 8 '6 216.0 ft2 1.0 0.75 0
16 N Bedroom InteriorFrame-Wood Main 4.0999 30 9 8 6 261.4 ft2 0 0 0.75 0
17 W Exterior Concrete Block-Int Insul Main 4.0999 5 5' 8 6 46.0 ft2 01 0.75 0 +
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
_ Ft In Ft In
..-:_�.._.,..�.;___....._.._._ W - Wood Bedrooms None .46 ryas 1 7_ �35.6 ft2
i/
2 N Wood Main None .46 3 7 2112
_ 3 W Wood Main None .46 2 5 7 16.9 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall a Overhang
V # Orrit ID Frame Panes NFRC - U-Factor SHGC - Area Depth Separation Int Shade Screening
1 S 1 Metal Double(Clear) Yes 0.65 0.3 37.4 ft2 3 ft 0 in 2 ft 0 in Roller shade None
V 2 S ,.1 Metal Double(Clear) Yes 0.65 0.3 21.0 ft2 3 ft 0 in 2 ft 0 in Roller shade None
3 S 1 Metal Double(Clear) Yes 0.65 0.3 64.8 ft2 3 ft 0 in 2 ft 0 in Roller shade None
/ 4 S 1 Metal Double(Clear) Yes 0.65 0.3 8.7 ft2 3 It 0 in 2 ft 0 in Roller shade None
5' S 1 Metal Double(Clear) Yes 0.65 0.3 28.0 ft2 3 ft 0 in 2 ft 0 in Roller shade None
I V 6 S 1 Metal Double(Clear) Yes 0.65 0.3 21.0 ft2 3 ft 0 in 2 ft 0 in Roller shade Now
f'✓ 7 E 2 Metal Double(Clear) Yes 0.65 0.3 81.7 ft2 8 ft 0 in 2 ft 0 in Roller shade None
8 N 3 Metal Double(Clear) Yes 0.65 0.3 28.0 ft2 3 ft 0 in 2 ft 0 in Roller shade None
9 N 4 Metal Double(Clear) Yes 0.65 0.3 32.4 ft2 3 ft 0 in 2 ft 0 in Roller shade None
10 N 5 Metal Double(Clear) Yes 0.65 0.3 26.7 ft2 25 ft 6 in 210 in Roller shade None
7/1/2016 1:53 PM EnergyGauge®USX'-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered,Proposed orientation. 1
Wall Overhang
# Ornt ID Frame, Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
- 11 W 6 Metal Double(Clear) Yes 0.65 0.3 32.4 ft2 3 ft 0 in 2 ft 0 in Roller shade None
12 E + 7 Metal Double(Clear) Yes 0.65 0.3 7.5 ft2 3 ft 0 in 2 ft 0 in Roller shade None
- 13 E 8 Metal Double(Clear) Yes 0.65 0.3 58.9 ft2 3 ft 0 in 2 ft 0 in Roller shade None
J 14 E 10 Metal Double(Clear) Yes 0.65 0.3 81.7 ft2 3 ft 0 in 2 ft 0 in Roller shade None
_.1L 15 N 11 Metal Double(Clear) Yes 0.65 0.3 15.3 ft2 3 It 0 in 2 ft 0 in Roller shade None
J 16 N 11 Metal° Double(Clear) Yes 0.65 0.3 21.0 ft2 3 ft 0 in 2 ft 0 in Roller shade None
17 N 11• Metal Double(Clear) Yes 0.65 0.3 52.4 ft2 3 ft 0 in 2 ft 0 in Roller shade None
V ,18 N 11 Metal Double(Clear) Yes 0.65 0.3 6.7 ft2 3 ft 0 in 2 ft 0 in Roller shade None
19 S 13• Metal Double(Clear) Yes 0.65 0.3 28.0 ft2 25 ft 0 in 3 ft 0 in Roller shade None
20 W 14 Metal Double(Clear) Yes 0.65 0.3 75.8 ft2 6 ft 0 in 2 ft 0 in Roller shade None
21 E 7 Metal Double(Clear) Yes 0.65 0.3 75.3 ft2 3 ft 0 in 2 ft 0 in Drapes/blinds None
4
GARAGE
# _ Floor Area _Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
--•_� 1 � 595.3364 ft2 _ 595.3364 ft2-y. �96 ft`--V-- ~.-11.66 ft
INFILTRATION i
i
# Scope Method SLA CFM 50 Et.A EgLA ACH ACH 50
1 Wholehouse Best Guess .0005 - 4902.4 269.14 506.15 .345 8.7434
HEATING SYSTEM
# System Type Subtype _ Efficiency Capacity Ca acit Block _
_ _ i _Ducts
_ 1 Electric Strip Heat None ^--COPA _ 24.55 kBtu/hr 1 ^4 sys#1�
2 Electric Strip Heat None COPA 34.1 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype _ Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split W SEER:16 36 kBtu/hr 1080 cfm 0.75 1 sys#1
2 Central Unit 'None SEER: 16 '60 kStu/hr 1800 cfm 0.75y 2 sys#2
HOT WATER SYSTEM
7- 7_ System-Type_ S_ubType Location EF `^ Cap Use SetPnt_ Conservation_
1 Electric v~Heat Pump~Garage 2.3 80 gal �80 gal 120 deg None
- t
. I
r
a
i t
a
• i
t
? P
7/1/2016 1:53 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
I
r
{
1
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None~ None ftz �
DUCTS `
—Supply— - Return - Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
L/�1 Attic 6 150 ft2 AtticA 93.45 ft _ Default Leakage Main (Dbfauft) (Default) 1 1
V/ 2 Attic 6 270 ft2 Bedrooms 93.45 ft Default Leakage Bedrooms (Default) (Default) 2 2 ?
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: ,
l
Conlin [[ �Jan [[ �Feb ki Mar [ ]A r [[ ]].Ma X]Jun [X]Jul [X]Au
Sep [ j Oct, [ j Nov [ ]Dec
Heating (X]Jan [X)Feb Mar [ )APr )May t ]Jun ( ]Jul [ ]Aug Sep [_]Oct. (X]Nov [X)Dec
Ventin [ JJ Jan [[ ]]feb Mar [Xj Apr ]]May [ J Jun [ ))Jul ( l Aug Se [x)Oct [X)Nov [[[ )Dec
Thermostat Schedule: HERS 2006 Reference _ Hours
Schedule Type 1. 2 3 4 5 6_ 7 8 9 10 11 12,
Cooling(WD) AM _ 78 78 78 78 78 78 78 78 80 80 _ 80 80
PM 80, 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 7878 78 78, 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM, 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68- 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
a
4 i
3
t
r
� i F
f
E i
1
r
7!1!2016 1:53 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
` � r
r
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business.and Professional Regulations ,
Residential Whole Building Performance Method f
E
DRESS: 9879 NE 13th Avenue PERMIT#:
Miami Shores, FL, 33138-
MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details.
COMPONENT SECTION _ — SUMMARY OF REQUIREMENT(S) W_ ' CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
i doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces:
1 gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& j 403.1 At least one thermostat shall be provided for each separate heating and
controls l cooling system. Where forced-air furnace is'primary system,
l programmable thermostat is required.,Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
_ J I meet the load. Y
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts.or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code. i
k
z 403.3.3 r Building framing cavities shall not be used as supply ducts. I
} ip
Water heaters ` 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2.-Provide switch of clearly marked circuit breaker
(electric)or shutoff(gas).-Circulating system pipes insulated_ to=R-2
+accessible manual OFF switch.
YMechanical 403.5 6 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from-attics,crawlspaces, garages or outdoors adjacent t/
l } to pools or spas_
Swimming Pools ` 403.9 Pool pumps and pool`pump motors with a total horsepower(HP)of= 1
Spas HP shall have the capability of operating at two or more speeds. Spas
# and heatedpools must have vapor-retardant covers or a liquid cover or /
¢ other means proven to,reduce heat loss except if 70% of heat from ✓ '
site-recovered energy. Off/timer switch required. Gas heaters minimum
— l thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters
_ E minimum COP=4.0 _
Cooling/heating 3 6 Sizing calculation performed&attached. Minimum efficiencies per
i Tables 503.2.3. Equipment efficiency verification required. Special
equipment l occasion cooling or heating capacity requires separate system or "
variable capacity system. Electric heat>10kW must be divided into two
r or more stages. .
Ceilings/knee walls 405.2.1 R-19 space permitting.
7/1/2016 1:53 PM EnergyGauge®USA-RaRes2010 Section 405.4.1 Compliant Software ' Page 6 of 6
l
ENERGY PERFORMANCE LEVEL (EP(.)
DISPLAY CARD
11111111111110
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the EnergyPerformance Index, the more efficient the home.
9879 NE 13th Avenue, Miami Shores, FL,•33138-
1. New construction or existing Addition 9. Wall Types Insulation Area
2.,Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2928.30 ft2
b.Interior Frame-Wood,Interior R=4.1 261.38 ft2
3. Number of units,if multiple family 1 c.Concrete Block-Int Insul,Adjacent R=4.1 216.04 ft2
4. Number of Bedrooms 5(2) d.N/A R= 1 ft2
5. Is this a worst case? No
10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 3738.00 ft2
6. Conditioned floor area(ft2) 3738 b.WA R= a ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.65 804.47 ft2 11.Ducts R ft2a.Sup:Attic,Ret:Attic,AH:Main 6 150
SHGC: SHGC=0.30 b.Sup: Attic,Ret:Bedrooms,AH:Bedrooms 6 270
b. U-Factor. N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
a. U-Factor. N/A ft2 a.Central Unit 36.0 SEER:16.00
SHGC: b.Central Unit 60.0 SEER:16.00
d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Strip Heat t24.6 COP:1.00
Area Weighted Average Overhang Depth: 5.302 ft. b.Electric Strip Heat ` 34.1 COPA.00
Area Weighted Average SHGC: 0.300
8...Floor Types Insulation Area 14.Hot water systems-Supplemental for addition
a.Crawlspace R=0.0 3738.00 ft2 a.Electric Cap:80 gallons
EF:2.3
b.N/A R= ft2
c.N/A ' R= ft2 b. Conservation features
None
15.Credits Pstat
r
I certify that this home has complied with the Florida Energy Efficiency Code for Building RRE ST
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: 0
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge,Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®,USA-FlaRes2010 Section 405.4.1 Compliant Software r
t
f
TABLE 402.4.2 z
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
4
Project Name: Remodeling at 9879 NE Rev Builder Name:
Street: 9879 NE 13th Avenue Permit Office:
City,State,Zip: Miami Shores,FL,33138- Permit Number:
Owner: Almeida Barrantes Jurisdiction: 231000
Design Location: FL,Miami
i
r:
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier. /
Breaks or joints in the air barrier are filled or repaired. ✓
j Air-permeable insulation is not used as a sealing material.
Air-permeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access(except unvented attic),knee wall door, or drop down
stair is sealed"
Walls Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/door jambs and framing is sealed. ' V
Rim joists Rim joists are insulated and include an air barrier. L'
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subfloor decking.
floors) Air barrier is installed at any exposed edge of insulation. `
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I I ;/
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by ✓
sprayed/blown insulation.
Garage separation Air sealing is provided between the garage and conditioned spacesw-
Recessed lighting. Recessed light fixtures are air tight, IC rated, and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation ✓,
extends behind piping and wiring.
1 i Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
sebaratinq them from the exterior wall.
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed. V
Common wall Air barrier is installed in common wall between dwelling units. ✓
HVAC register boots HVAC register boots that penetrate building envelope are sealed to C
subfloor or drVwall.
Fireplace Fireplace walls include an air barrier. . N
4 1
EnergyGaugeS USA,-FlaRes2010 Section 405.4.1 Compliant Software
E.
1
1
w-
ASHRAE HANDBOOK,2004 FUNDAMENTALS VOLUME, BUILDING
CHAPTER 26 COOLING LOAD CALCULATIONS:
1 REMODELING AND ADDITION AT:
9879 NE 13th Avenue AREA: 3,738 SQ.FT. t
Miami Shores,FL 33138 DATE 07/01/18
COOLING LOAD CALCULATIONS:F. SUMMARY _ PER ACCA MANUAL"J' t
CONDITIONS: INSULATION:
91 FDB,79 FWB,OUTSIDE WALLS R-4.1
76 FDB,50-60%RH,INSIDE ROOF R-30
TRANSMISSION: COOLING LOAD, BTUH'
SENSIBLE LATENT
WALLS: Q=AREA'U(THER.COEFFJ'Tdeq --
Q= 2928.3 X 2.6 7614
Q= 477.42 X 1.2 573
DOORS:
Q= 73.5 X 8.61 632
ROOF Q= 3738 X 1.4 5233
f
SOLAR
(DOUBLED TINTED GLASS)
GLASS Q= AREA-FACTOR(OSF'SH.COEFF.)
N 0= 202.7 X 25.938 5258 t
W Q= 109.1 X 38.961 4251
E Q= 311 X 40.657 12644
S Q= 191.6 X 36.894 7069
INTERNAL HEAT GAIN:
PEOPLE Q=#PEOPLE'FACTOR
SEN. Q= 6 X 300 1800
LAT. Q= 6 X 230 1656
POWER Q=AREA'FACTOR(APPL.)
Q= 3738 X 3 11214
TRANSMISSION: V
Q=#PEOPLE'CFM'T.DIFF.'FACTOR),
SEN. Q= 6 15 15 1.08 1458
Q=#PEOPLE'CFM'T.DIFF.'FACTOR)
LAT. Q= 6 15 50 0.68 18360
DUCT HEAT GAIN:
Q=FACTOR(R-6)'D.LGl100
Q= 1.4 1200 420 100 7056
4 t
SENSIBLE TOTAL 64801
LATENT TOTAL 20016 t
GRAND TOTAL(SEN.+LATENT}= 84817
t
r
Manual J:8th Edition
Residential Heat Loss and Heat Gain Calculations } Page 1
t
• 1
a
ASHRAE HANDBOOK,2004 FUNDAMENTALS VOLUME, BUILDING
CHAPTER 26 COOLING LOAD CALCULATIONS:
i
HEATING LOAD CALCULATIONS:
CONDITIONS: 70FDB,INSIDE HEATING LOAD,KW i
47FDB,OUTSIDE }
HEATING:
TRANSMISSION:
i Q=AREA'FACTOR(U FACT.-TEMP DIFF.) t
GLASS: Q= 804.47 X 29 23330'
r i
i WALLS: Q= 2928'.3 X 4 11713
ROOF: Q= 3738 X 0.9 3364
z
VENTILATION:
Q=FACTOR'CFM'T.DIFF./FACTOR
(-)INTERNAL HEAT GAIN(L.P.A.), i
SENSIBLE:
Q= 1.08 2925 0.4 23 21528 7535 t
w
HUM LOAD
Q=FACTOR'SHD'CFM r
Q= 0.67 10 2925 0.4 7839
DUCT HEAT LOSS
Q=FACTOR(k-6)'D.LG/1000
Q= 1.4 900 420 ! 1000 529 t
TOTAL 54310
OR 15.93
i
EQUIPMENT SIZING:
BASED ON THE CO EATINC�L D CALCS.
USE(2)3&5 TONXC° jT9E'ddl7STj1fl 170,700 BTU SENS.(2925 CFM)(SEER-16)(109.1%)
WITH STRIP H�j ! KW^h_ •°. 1�/
NOTE:OR EQ® QU ENT ,0
J /
Cesar A.Mer
Professional ear 1%.No 62 q-
(305)484-7276 1 '• •°• '`'
PROFEs��
i
Manual J:8th Edition
Residential Heat Loss and Heat Gain Calculations Page 2
I
f
` 3
k
ASHRAE HANDBOOK,2004 FUNDAMENTALS VOLUME, AMAIN
CHAPTER 26 COOLING LOAD CALCULATIONS:
REMODELING AND ADDITION AT:
9879 NE 13th Avenue AREA: 1,353 SQ.FT.
Miami Shores,FL 33138 DATE: 07/01/16
COOLING LOAD CALCULATIONS: SUMMARY PER ACCA MANUAL"j;; s
CONDITIONS: INSULATION:
a 91 FDB,79 FWB,OUTSIDE. WALLS R4.1
76 FDB,50-60%RH,INSIDE ROOF R-30
s �
TRANSMISSION: COOLING LOAD, BTUH
SENSIBLE LATENT
WALLS: Q=AREA-U(THER."COEFF.)'Tdeq —
Q= 1290.2. X 2.6 3355 , {
Q= 505.6 X 1.2 607
DOORS:
Q= 38 X 8.6 327
4
ROOF Q= 1353 X 1.4 1894
J
SOLAR (DOUBLED TINTED GLASS)
GLASS Q= AREA'FACTOR(OSF•SH.COEFF.)
NQ= 95.4 X 25.938 2474
1 W Q= 0 X 38.961 0
E Q= 140.6 X 40.657 5716
S Q= 28 X 36.894 1033
INTERNAL HEAT GAIN: l
PEOPLE Q=#PEOPLE'FACTOR
SEN. Q= 6 X 300 1800 t
LAT. Q= 6 X 230 1656 e
POWER Q=AREA-FACTOR(APPL.)
Q= 1353 X 3 4059
TRANSMISSION:
0=#PEOPLE'CFM'T.DIFF.-FACTOR)
SEN. Q= 6 15 is 1.08 1458
Q=IPEOPLE'CFM•T.DIFF.-FACTOR) '
LAT. Q= 6 15 50 0.68 '11352.6
DUCT HEAT GAIN.
Q=FACTOR(R-6)'D.LG/100
Q= 1.4 1200 150 100 2520
-
SENSIBLE TOTAL 25243
LATENT TOTAL 13009
GRAND TOTAL(SEN.+LATENT)= 38252
,
1
Manual J:8th Edition f
Residential Heat Loss and Heat Gain Calculations Page 3 F
Y
ASHRAE HANDBOOK,2004 FUNDAMENTALS VOLUME, MAIN
CHAPTER 26 COOLING LOAD CALCULATIONS:
HEATING LOAD CA(_CULATIONS:
CONDITIONS: 70FD8,INSIDE s. HEATING LOAD,KW
47FDB,OUTSIDE
, Y
HEATING:
TRANSMISSION:
Q=AREA-FACTOR(U FACT.-TEMP DIFF.)
' GLASS: Q= 416.2 X 29 12070
t'
WALLS: Q= 1290.2 X 4 5161 tyy
h
ROOF: Q= 1353 X 0.9 1218
f
. . f
VENTILATION:
Q=FACTOR'CFM'T.DIFF./FACTOR
(-)INTERNAL HEAT GAIN(L.P.A.)
SENSIBLE:
Q= 1.08 1175 0.4 23 - 9837 1838
t
HUM LOAD
Q=FACTOR•SHD'CFM
Q= 0.67 10 1175 0.4 3149
DUCT HEAT LOSS
0=FACTOR(R-6)'D.LG/1000
Q= 1.4 900 150 / 1000 189
TOTAL 23624
OR 6.93
EQUIPMENT SIZING:
BASED ON THE COOL HS"4b' ING LOAD CALCS. t
USE 3 TON A/C U ?� f9RAH T � /29,000 BTUH SENS.(1200 CFM)(SEER-16.0)'(114.88%) I
RHEEM 16AJL3 C.U.&•RHPkt HM35 AIR HANDLER
WITH STRIP •• I
NOTE:OR E QU ENT••• r b�
s V bti
t Cesar A.M �
Professiona Inger L c. No
(305)484-72 •• co10
OQ�•.
I h��70FESS x
I
Manual J:8th Edition
Residential Heat Loss and Heat Gain Calculations Page 4
t
r
' r
a t
i
1
I
ASHRAE HANDBOOK.2004 FUNDAMENTALS VOLUME, BEDROOMS a
CHAPTER 26 COOLING LOAD CALCULATIONS:
REMODELING AND ADDITION AT:
9879 NE 13th Avenue AREA: 2,385 SQ.FT.
Miami Shores,FL 33138 DATE: 07/01/16
COOlJNG'LOAD CALCULATIONS: SUMMARY PER ACCA MANUAL"J" `
CONDITIONS: INSULATION:
91 FDB.79 FWB,OUTSIDE WALLS RA.1
76 FDB,50-60%RH.INSIDE ROOF R-30
TRANSMISSION: COOLING LOAD. BTUH
SENSIBLE LATENT
WALLS: Q=AREA-U(THER.COEFF.)`Tdeq - ---
�— 8
Q= 1812.2 X 2.6 47112 k
Q= '505.6 X 1.2 607
DOORS: a
Q= 35.6 X 8.6 306
ROOF Q= 2385 X 1.4 3339
i
SOLAR (DOUBLED CLEAR GLASS)
GLASS Q= AREA'FACTOR(OSF'SH.COEFF.)
N Q= 87.1 X 25.938 2259
W Q= 183.5 X 38.961 7149
E- Q= 170.9 X 40.657 6948 I
S Q= 179.4 X 36.894 6619 L
INTERNAL HEAT GAIN:
i
PEOPLE Q=#PEOPLE'FACTOR
A
SEN. Q= 5 X 300 1500
LAT. Q= 5 X 230 1380 i
POWER Q=AREA'FACTOR(APPL.)
Q= 2385 X 1 2385
> a
TRANSMISSION:
i
Qa4PEOPLE'Cf M'7.DI FF.•FACTOR)
l SEN. Q= 5 15 15 1.08 1215
Q=4PEOPLE'CFM'T.DIFF.-FACTOR)
LAT. Q= 5 15 50 0.68 14407.5
DUCT HEAT GAIN:
Q=FACT0R(R-6)•D.LG/100
Q= 1.4 1200 270 100 4536
i
SENSIBLE TOTAL 41575
LATENT TOTAL 15788 l
GRAND TOTAL(SEN.+LATENT)= 57363
}
J
F 1
,Manual J:8th Edition
Residential Heat Loss and Heat Gain Calculations Page 5 1
l t
(
S
±
ASHRAE HANDBOOK,2004 FUNDAMENTALS VOLUME, BEDROOMS
CHAPTER 26 COOLING LOAD CALCULATIONS'.
±
i
- I
HEATING LOAD CALCULATIONS:
±
CONDITIONS: 701FDB,INSIDE HEATING LOAD,KW 1
± 47FDI3,OUTSIDE
HEATING:
TRANSMISSION:
Q=AREA'FACTOR(U FACT.-TEMP DIFF.)
GLASS: Q= 630.9 x 29 18296
WALLS: Q= 1967.7 x 4 7951
ROOF: Q= 2385 x 0.9 2147
VENTILATION:
Q=FACTOR'CFM`T.DIFF./FACTOR
(-)INTERNAL HEAT GAIN(L.P.A.)
• SENSIBLE: r
{
Q=. 1.08 1725 0.4 23 16044 1096
1
HUM LOAD
Q=FACTOR•SHD'CFM
Q= 0.67 10 1725 0.4 4623
DUCT HEAT LOSS
Q=FACTOR(R-6)-D.LG/1000
Q= 1.4 900 270 1 1000 340
`i
?, TOTAL 34453
OR 10.10
EQUIPMENT SIZING: t
BASED ON THE COOLIN I D CALCS.
USE 5 TON A/C UNIT Or! L/4 %499 BTUH SENS.(1725 CFM)(SEER-16.0)(100.3%)
RHEEM 16AJL60A0 8�R'N•pl�k{M6bUJA*F4#jANDLER
WITH STRIP HEAT
NOTE:OR EQUIV •f:EQ�IIPMnEh
• J bV
Cesar A.Me
Professional nr LiC No 621 de f••J�. k
(305)484-7276OFEW
It •. Q „
i tt A ••
3
Manual J:8th Edition
Residential Heat Loss and Heat Gain Calculations Page 6
• t