Loading...
RC-17-387 (2) Miami Shores Village c I� z� g Q 0 3 X117 Building Department n r\co'A' C) . 10050 N.E.2nd Avenue, Miami Shores,Florida 33138 5, Tel:(305)795-2204 Fax:(305)756-8972 --F INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 204 BUILDING Master Permit No.5;�C /7—c3,'7 PERMIT APPLICATION Sub Permit No. Q BUILDING ELECTRIC ❑ ROOFING, ❑ REVISION •0 EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL E]PUBLIC WORKS CHANGE OF CANCELLATION 0 SHOP CONTRACTOR t DRAWINGS JOB ADDRESS: 672 NE 98 St. City• Miami Shores County: Miami Dade Zip: t Folio/Parcel#: 11-3206-017-1780 Is the Building Historically Designated:Yes NO x Occupancy Type: ' Load: Construction Type: Flood Zone: BFE: , FFE: S � OWNER: Name(Fee Simple Titleholder): Carol Invest USA, Inc Phone#: Address: 990 Biscayne Blvd. Suite 801 City: Miami' state: Florida !' zip: 33132 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Joseph S. Robbio, Inc Phone#:"(954)663-6743 Address: 9400 S. Meadows Circle city: Miramar state: Florida Zip: 33025 Qualifier Name: Joseph S. Robbio Phone#:(954)663-6743 State Certification or Registration#: CBC 059462 Certificate of Competency#: DESIGNER:Architect/Engineer: Victor Bruce Phone#:(305) 310-5030 Address: 370 NE 101 St. city: Miami Shores State:Fl. zip: 33138 Value of Work for this Permit:$ NA Square/Linear Footage of Work:• Type of Work: ❑ Addition ❑ Alteration ® New ❑ Repair/Replace ❑ Demolition Description of Work: Submit Truss drawings for approval �hay �'{' .1 •lE�.l�`!r 4'] hit . l,j a � 0 ,d"i'...d \ -ly.,•1. .' � ,�• « Specify color of color"tli�ru tile: - v- ' -- _ F 'gip 1 } } Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) ' f ' Bonding Company's Name(if'applicable) Bonding Company's Address City State, Zip , Mortgage Lender's Name(if applicable) Mortgage Lender's Address+ City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..:.. , OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building'permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Joseph S. Robbio Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this. day of N)au-,- 20 1-1 by v1cl day of t 20 I- by Mnfm P,vUZ.Z who i ersonally kno n to ,�c�SP+h �. RobesiU ,who is p rsonally know to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Gt,�G Cyt, Pri Print: LUCIA G ISASI Seal: Seal: s MY COMMISSION#FF182628 MY COMMISSION#FF182628 �' dF• EXPIRES December 10,2018 EXPIRES December 10,2018 " ^^ (407)398-0153 FloridallotaryService.com (407)398-0153 FloridallotaryService.com i. i J APPROVED BY Plans Examiner Zoning c5 ` Structural Review Clerk (Revised02/24/2014) F ' I Project Information: Customer: Job Number: ` DESARATA BLDG. 161116 Job Name: 3 CUSTOM TRUSS BRUZZI RES 1890 W. ATLANTIC AVE Address: -DELRAY BEACH, FL 33444 672 NE 98TH STREET l 954-786-8800 city,sr,ZIP: MIAMI SHORES, FL 4 General Truss Engineering Criteria & Design Loads Building Code and Chapter: Computer Program Used: FBC2014/TPI2007 MiTek Version: 8.02 Nov 18 2016 Gravity. Gravity. 55.0 psf ROOF TOTAL LOAD N/A Wind 175 mph from MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 This package includes a Truss Index Sheet and ***individual truss design drawings,together with the attached index of the Truss System design drawings. I hereby certify that this serves as a cover sheet in accordance with Chapter 61 G15-31.003 of the Florida Board of Professional Regulations. Note: Furthermore,the responsibility of the undersigned is solely limited to the design of the truss components shown. The suitability and use of these trusses for any.building is the responsibility of the building designer. r Delegated Engineer: CARL G. FOfi Br� •'••••• •••••• FL LIC. NO: ZU699 .".•• •• ��� '� a�'�t��, 555 S. POMPAi'DQ PKWY. �••••� POMPANO-PE�A", F�!33069 • • (954).682-665Y ;•••• ••;••• r • 1 06/06/17 Al • • • • 2 06/06/17 A2 .F[� C 7 • • • •••••• UFA!„ REVIE-i ✓ �"" .• • .••• • • 3 06/06/17 A4 •• ' 4 h, 06/06/17 AG 1 APPROVED 5 06/06/17 EJ2 b�cue$.brntce., Inc:. 6 06/06/17 HJ5 D Q 4WQ1 od n Careaed h+we 7 06/06/17 Jj ❑9rl*4ftftd;kM' Tris mvinrr is 6*saa peaewk cor+tprraenoe 8 06/06/17 J2 me =00 04 00.;woject.and m the he �@ Wt,tyle intim- aton.given 9 06/06/17 J3 Jtcr'n� 0oeaanerMa CAWecoons or tmHr�rlis rem®n ba she{ **ms during tiffs re�rev de net 160W. conlwactor from 0U1Vk-*wt h the fe,* vaacOK Of the pians and sfxrclrW060M AW(ywtt Qt a apedfic item t chap no vrckufc aprxovat:rr an assembly of wfddr the item is a r:omnnnent contractor is ti'+MSAge for dnnensitrns Su ht>confirmed acrd corrMataJ at Ifrr;}ut;Hc:infwnlatlwt that rxnam snk..'ty to the fabrication r>n>Gossps W to the means,mothods,trchniquas,aoWanpt✓>t am Pro"ros of construction; coordinom- of tta work or an trados;and for pod" at *A in a safe and satiaracbry marmor, t J]ate BY ' f Page 1 of 1 Job Truss Truss Type Qty Ply BRUZZI RES 161116 Al Half Hip 1 1 Job Reference(optional) Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14:25:32 2017 Page 1 1 2 010-0 3 6-6-5 11-9-0 ID:knKbO4ep9836JxrasWFrzJyRtuJ-5auIHpfC�Pfe-0K�VBsHxG41w0eBLpN1z;B OBKxLyw9ZX I- 1-2-0 6-6-5 I 5-2-11 I 6-3-8 3- Scale=1:33.5 5x5= 4 14 15 5 2.80 12 I� 0 1.5x4 II 3 13 4x4 i N N 12 ;T .25112 2 l� l 8 6 7 3x4= 3x4= 4x10= 10-0-3 10-9-7 �� 6-6-5 1 11-9-0 F 13-10-0 14-3-$ 18-0-8 1$A 0 3- 6-2-13 5-2-11 2-1-0 5- 3-9-0 3- Plate Offsets X Y-- 2:0-3-2 Ede •••• LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl Ud • • • PLATES GRIP • TCLL 30.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) -0.13 8 >999 360 • • MT20.••.•X44/190 •• TCDL 15.0 Lumber DOL 1.25 BC 0.62 Vert(TL) -0.31 6-8 >689 240 00000* •• • see*** BCLL 0.0 * Rep Stress Incr YES WB 0.51 Horz(TL) -0.02 5 n/a n/a •• :•• . . • BCDL 10.0 Code FBC2014/TPI2007 Matrix-AS Wind(LL) 0.18 8 >999 240 .• Weight:.7�.Ib FT=V S%••: LUMBER- BRACING- 0000 •••• ••••• TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathin@ diii;"y applied. • 6000* BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly apQliebe • •.•.: *00000 WEBS 2x4 SP No.3 MiTek recommends tha4�ta¢¢ilizers and required cross bracing be installed during truzs erOclipn,in accordance with Stabilize& Installation guide. • • • • 009000 REACTIONS. (Ib/size) 5=958/4-0-0 (min.0-1-8),2=1108/0-8-0 (min.0-1-8) . . . :0900:. Max Horz 2=268(LC 8) • • • •••••• Max Uplift5=-469(LC 9),2=-635(LC 8) . . Max Grav5=958(LC 1),2=1108(LC 21) •• FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/25,2-12=-2607/1355,3-12=-2552/1373,3-13=-2604/1463,4-13=-2552/1480,4-14=-1166/687, 14-15=-1166/687,5-15=-1166/687 BOT CHORD 2-8=-1496/2485,6-8=-882/1396,6-7=0/0,5-6=-802/1363 WEBS 3-8=-471/406,4-8=-749/1234,4-6=-569/483 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat. 11;Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-2-6 to 1-9-10,Interior(1)1-9-10 to 11-9-0,Exterior(2)11-9-0 to 15-11-15 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Bearing at joint(s)5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 469 Ib uplift at joint 5 and 635 Ib uplift at joint 2. 8)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)5. 9)This truss design requires that a minimum of 7/16"structural wood sheathing be applied directly to the top chord and 1/2"gypsum sheetrock be applied directly to the bottom chord. 10)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard 1 CARR. 0. FORBES FL LIC, NO:20699 566 S.POMPANO PKWY. PAMP'ANO BEACH,FL. 33069 (954)692=6661 Job Truss Truss Type Qty Ply BRUZZI RES 161116 A2 Half Hip 1 1 Job Reference(optional) Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14:25:33 2017 Page 1 ID:knKbO4ep9836JxrasWFrcJyf� _77 mS7U9QrAZMoxfm2renJa8Zgok8KmKRg5ZwtTnyw9ZW 0-0-3 -1-2-d 7-6-1 13-10-0 _ 1A- 16-11-3 20-0-8 2Q-4r0 1-2-0 7-6-1 6-3-15 -5- 2-7-11 3-1-5 -32 f Scale=1:36.0 = 2.80 12 5x5 6 15 14 3x4 7 5 12 13 3x4 3x4= 3x4 4 3 8 3x6 19 2 7.25 1 v1 iv 0 11 9 10 3x4= 1.5x4 II 4x8= 10-0-3 10-9-7 3 7-6-1 13-10-0 _ to-3$ 16-11-3 20-0-8 2Q-4 0 -3- 7-2-9 6-3-15 -5- 2-7-11 3-1-5 -3 000 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d • , PLATE0•„15'RIP •,•••• TCLL 30.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.1011-18 >999 360 • • • MT20 244/190 • TCDL 15.0 Lumber DOL 1.25 BC 0.58 Vert(TL) -0.2711-18 >773 240 • • ,•*,•, •, BCLL 0.0 Rep Stress Incr YES WB 0.87 Horz(TL) -0.01 7 n/a n/a •• ••• •• • ; •••••• BCDL 10.0 Code FBC2014/TP12007 Matrix-AS Wind(LL) 0.1511-18 >999 240 ,. ; Weight:87P FT Z0% , 0000 0000 • • LUMBER- BRACING- , TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing diteetly applied*••• 00000 BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly appljpd,,, , , 0*609 •• WEBS 2x4 SP No.3 MiTek recommends tU Itp4ilTzers ana Leal it cross pwip• be installed during truss erection,in accordance with Stabilizer) Installation guide. :00:0: • 0 REACTIONS. (Ib/size) 7=-606/5-0-0 (min.0-1-8),2=987/0-8-0 (min.0-1-8),8=1870/5-0-0 (min.0-1-8) • • • • •••••• Max Horz 2=371(LC 8) • , :•••0• , , Max Uplift7=-607(LC 21),2=-577(LC 8),8=-1018(LC 8) • • • •*000: Max Grav7=360(LC 8),2=987(LC 1),8=1871(LC 21) 00 0 0 0 0• , •• FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/25,2-19=-1959/875,3-19=-1897/896,3-4=-590/196,4-5=-531/214,5-6=-557/992,6-15=-532/983 BOT CHORD 2-11=-1114/1848,9-11=-1114/1848,9-10=0/0,8-9=-405/682,8-13=-1200/643 WEBS 3-11=0/267,6-8=-559/415,5-9=0/218,3-9=-1388/818,5-8=-1481/828 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft;B=45ft;L=24ft,eave=4ft;Cat. II;Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-2-6 to 1-9-10,Interior(1)1-9-10 to 16-11-3,Exterior(2) 16-11-3 to 19-3-8 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 I 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 607 Ib uplift at joint 7,577 Ib uplift at joint 2 and 1018 Ib uplift at joint 8. 7)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)7,8. 8)This truss design requires that a minimum of 7/16”structural wood sheathing be applied directly to the top chord and%"gypsum sheetrock be applied directly to the bottom chord. 9)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard i CARL G. FORBES FL LIC. NO. 20699 555 S. POMPANO PKWY.. PAMPANO BEACH, FL. 33069 (954)682.6651 Job Truss Truss Type Qty Ply BRUZZI RES Monopitch 6 1 161116 Truss 1_ 1 � Job Reference(optional) Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14:25:34 2017 Page 1 0-0-3 ID:knKbO4ep9836Jxra� r JyRtuJ-1y0WiVRUxtUfZpLFOMJY7L5wQ8PgVvJpKDgQ?Eyw9ZV -1-2-(� 7-6-1 14-3-8 4 -1 17-2-10 i 22-0-8 22-4;-0 ' 1-2-0 7-0-1 6-9-7 0-219 2-8-10 4-9-14 0-3 8 2.80 12 Scale=1:39.0 10 6 0 ' Ian 16 d 3x4 1.5x4 5 11 4x4 i 4 3x4 3 15 7.25 12 � 2 � 1 I0 1 o p 0 7 8 3x6= 9 4x8-i 1.5x4 II 10-0-3 10-9-7 03 14-3-8 7-6-1 14-3-8 _ 22-0-8 2 - 0 0 3-8 7-2-9 6-9-7 7-9-0 1_1% PlateOffsets(X,Y)-- [6:0-2-14,Edge],[7:0-5-0,0-2-41 eggs _ LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d 0 0•• PLATES s•0 GRIP ••••a• TCLL 30.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) -0.22 9-14 >999 360 • • MT20 s g e s e 244/190 00 TCDL 15.0 Lumber DOL 1.25 BC 0.96 Vert(TL) 454 9-14 >472 240 00 ••• •• + 000090 BCLL 0.0 * Rep Stress Incr YES WB 0.38 Horz TL -0.10 6 n/a n/a go, • BCDL, 10.0 Code FBC2014lrP12007 Matrix-AS Wind(LL) 0.32 9-14 >793 240 Weight:87 Ib FT=@@OA••• _ • •• eggs • • LUMBER- BRACING- •••• 0000 00000 TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathi6i@ 496wUy applied. 0 00,0 g g BOT CHORD 2x4 SP N0.2*Except* BOT CHORD Rigid ceiling directly apQlo g 0 0 0 8 00 0 0 g g g g 0 B1:2x4 SP M 30 WEBS 1 Row at midpt 3-' 0 WEBS 2x4 SP No.3 with 2x4 SP No.3 with?0'10p 131"x3")nai1S and cross bradb spacing of 20-0-0 oc. • 0 0 0 s 0 0 0 g g 0 •eggs• MiTek recommends t1%�flhbifizers ang required crosst +wg+ be installed during truss erection,in accoraanc:with Stabilizer s •• REACTIONS. (Ib/size) 6=1177/8-0-0 (min.0-1-8),2=1286/0-8-0 (min.0-1-8) Installation guide. Max Horz 2=457(LC 8) Max Uplift6=-691(LC 8),2=-729(LC 8) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/25,2-15=-3555/1711,3-15=-3516/1732,3-4=-2026/911,4-5=-1896/924,5-16=-2281/1248, 10-16=-2198/1253 BOT CHORD 2-9=-2019/3424,7-9=-2019/3424,7-8=0/0,7-11=-1520/2562 WEBS, 3-9=0/268,3-7=-1585/968,5-7=-783/608 NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat. II;Exp C;Encl.,G6pi=0.18;MWFRS(directional)and C-C Exterior(2)-1-2-6 to 1-9-1-�,Interior(1)1-9-10 to 21-3-4 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Bearing at joint(s)6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 691 Ib uplift at joint 6 and 729 Ib uplift at joint 2. 6)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)6. 7)This truss design requires that a minimum of 7/16"structural wood sheathing be applied directly to the top chord and 1/2'gypsum sheetrock be applied directly to the bottom chord. 8)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard i CARL G. FORBES FL LIC. NO: 20699 666 S. POMPANO PKWY. PAMPANO BEACH,FL. 33069 (954)5$2-6651 Job Truss Truss Type Qty Ply BRUZZI RES 161116 AG1 Half Hip Girder 1 1 Job Reference(optional) Cuslom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14:25:34 2017 Page 1 10-0-3 ID:knKbO4ep9836JxrasWFrzJyRtuJ-1yOWtVRUxtUfZpLF04jj 7}5wY8T?VxJpKDgQ?Eyw9ZV -1-2-0 -4 6-6-14 10-2-14 13-10-0 16-0-8 1 0 1-2-0 6-6-14 3-8-0 3-7-2 2-2-8 -3 Scale=1:29.5 4x4= 2.80 F12 3x4= 3 4 15 12 16 5 -- T2 Io 13 t4 4 4x4 i 2 dd 83x4= 7.25 12 6 7 3x4= 4x8= 10-0-3 10-9-7 Q-3$ 6-6-14 10-2-14 13-10-0 14-3-$ 16-0-8 16-4x0 tl-3-8 6-3E 3-8-0 3-7-2 -5- 1-9-0 -3- LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) -0.09 8-11 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.68 Vert(TL) -0.22 8-11 >855 240 BCLL 0.0 Rep Stress Incr NO WB 0.25 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC20141TPI2007 Matrix-MS Wind(LL) 0.13 8-11 >999 240 Weigh;ttV• FT=20% • • • • LUMBER- BRACING- •• • •• • • TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied orQ-14-1 oc puns.• BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly ap�llet!19-1-9 oc bPatin6. ••rli•••' WEBS 2x4 SP No.3 MiTek recommends t a ti7a8Mzers and req fired cross 6V�p9• be installed during trusEPArection,in accerdanoe with Stabilizer• Installation guide. •....• ••l,, • REACTIONS. (Ib/size) 5=847/2-0-0 (min.0-1-8),2=999/0-8-0 (min.0-1-8) . • •••••• • • ••••• Max Horz2=165(LC 8) • • • • • Max Uplift5=-494(LC 9),2=-625(LC 8) •• •• •• •• •••••• FORCES. (lb)-Maximum Compression/Maximum Tension •• •: • •• TOP CHORD 1-2=0/25,2-13=-2099/1207,13-14=-2074/1209,3-14=-2039/1225,3-4=-1995/1241,4-15=-1064/567, 12-15=-1 4/567,112-16=-3QG015g;5-16=5 5156 BOT CHORD 2-8=-1245/1985,6-8=-1202/1916,6-7=0/0,5-6=-654/1234 • • • • • WEBS 3-8=-22/185,4-8=-136/183,4-6=-981/732 .. • ••• • • • NOTES- ••• 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph,TCDL=8.Opsf,BCDL=4.Opsf;h=25ft;B=45ft;L=24ft,eave=4ft;Cat.II;Exp C;Encl.,GCpi=0.18;MWFRS (directional)and C-C Exterior(2)-1-2-6 to 1-9-10,Interior(1)1-9-10 to 6-6-14,Exterior(2)6-6-14 to 10-9-13 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Bearing at joint(s)5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 494 Ib uplift at joint 5 and 625 Ib uplift at joint 2. 8)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)5. 9)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard CARL G. FORBES FL LIC. NO: 20699 666 S.POMPANO PKWY. PAMPANO BEACH, FL. 33069 (954)682.5651 Job Truss Truss Type Qty Ply BRUZZI RES 161116 EJ2 Jack-Open 4 1 Job Reference(optional) _ Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 13 2016 Print:8.020 s Nov 18 2fb1@LMiTek Industries,Inc. Thu Jul 20 14:25:34 2017 Page 1 10-1-1 ID:knKbO4ep9836JxrasWFrzJyF td,UyOWVRUxtUfZpLFOMJY7L5318bBV_HpKDgQ?Eyw9ZV -1-2A 2-2-8 2-6- 1-2_, 2 0 —1— 2-2-8 0-3-8 Scale=1:14.4 3 i 8 7.25 12 / 0 a vi 1 A2x4 81 4 1 10-1-1 10-1-1 11-6-6 0-3-8 2-6-0 _ 01 33 2 2-8— -' Plate Offsets(X Y)-- I2:0-4-1 Edge] LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.23 I Vet(LL) -0.00 7 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.15 Vert(TL) -0.00 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a `•`• BCDL 10.0 Code FBC2014/TPI2007 Matrix-MP Wind(LL) -0.01 4-7 >999 240 • • Weight:•1Q"• FT=Q994o•• LUMBER- BRACING- • • • • TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheat4R L t&ty applied'&2'1 0 oc pullM..••• BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applfeel"$0-0-0 oc bra•ing. • • MiTek recommends that 61ebilizers ando@quired cross racing• be installed during trU9'%Wgrjitn,in a&9rgjgp6 with S"U7.pj Installation uide. • • REACTIONS. (Ib/size) 3=78/Mechanical,2=275/0-8-0 (min.0-1-8),4=27/Mechanical --...... o..*.: '� -•••• Max Horz 2=1 94(LC 12) •• •• •• •• •••••• Max Uplift3=-62(LC 12),2=-189(LC 12) • Max Grav 3=90(LC 17),2=275(LC 1),4=42(LC 3) • ••• •• • • • • •••••• FORCES. (lb)-Maximum Compression/Maximum Tension • • • • • TOP CHORD 1-2=0/58,2-8=-71/61,3-8=-60/75 �• � ��� � • � BOT CHORD 2-4=0/0 • • NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat. 11;Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-2-14 to 1-9-2,Interior(1)1-9-2 to 2-5-4 zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 62 Ib uplift at joint 3 and 189 Ib uplift at joint 2. 6)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard CARS. 0. FORBES FL. LIC. NO: 20699 666 S. POMPANO PKWY. PAMP'ANO BEACH, FL. 33069 (964)682.6651 Job Truss Truss Type Qty Ply BRUZZI RES 161116 HJ5 Diagonal Hip Girder 11 1 Job Reference (optional) I Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14: 2017 Page 1 10-0-3 ID:knKbO4ep9836JxrasWFrzJyRtuJ-V9auvgR6hAcVBywRy3gnfZe9cYoq 1' _YtP_Xgyw9zU I -1-5-6 I 3-10-2 6-6-9 6-1 -is 1-5-6 3-10-2 2-8-7 0-3-8� Scale=1:15.6 3 2.59 F12 9 8 T1 �( 2 qq 10 11 4 3x4= 3x4= i 10-0-3 10-0-3 11-6-1 ,0-3-8 6-10-1 0-3-8 6-6-9 Plate Offsets(X,Y)-- [2:0-2-6 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.14 4-7 >594 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.70 Vert(TL) -0.33 4-7 >246 240 BCLL, 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) 0.01 2 n/a n/a 0•• BCDL 10.0 Code FBC2014fTP12007 Matrix-MP Wind LL 0.20 4-7 >408 240 9 • • Wind(LL) � � •Weight:�91b FT=Q(i�',�••• • LUMBER- BRACING- • • •• ••• •• TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathiRj Si=e*cfy applied0o}6-t-0 oc puAR?.•' BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied eM10-0-0 oc braoing. • 0 MiTek recommends tha#81lo ilizers and osqui•ed cross bracing• be installed during tru?sejV4i8n,in ac1WgWV9 with St41WW6 • REACTIONS. (Ib/size) 3=262/Mechanical,2=530/2-1-0 (min.0-1-8),4=104/Mechanical Installation guide. • • 0 • • • Max Horz 2=170(LC 4) 00 09 •• •• 0.0 0.9 Max Uplift3=-207(LC 4),2=-405(LC 4),4=-24(LC 4) • *00000 Max Grav 3=262(LC 1),2=530(LC 1),4=125(LC 3) 0 • • • • 0000•• •0900• FORCES. (Ib)-Maximum Compression/Maximum Tension • • • '• • TOP CHORD 1-2=0/28,2-8=-9117,8-9=-53/2,3-9=-48/45 • • • •••••• •• • 090 • • • BOT CHORD 2-10=0/0, 10-11=0/0,4-11=0/0 • • NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft;6=45ft;L=24ft;eave=4ft;Cat.ll;Exp C,Encl.,GCpi=0.18;MWFRS (directional);Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 207 Ib uplift at joint 3,405 Ib uplift at joint 2 and 24 Ib uplift at joint 4. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)122 Ib down and 22 Ib up at 3-0-11,and 54 Ib down and 92 Ib up at 3-1-6,and 123 Ib down and 52 Ib up at 5-5-13 on top chord,and 51 Ib down and 32 Ib up at 3-0-11,and 17 Ib down and 21 Ib up at 3-1-6,and 26 Ib down and 0 Ib up at 5-5-13 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 7)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert: 1-3=-90,4-5=-20 I Concentrated Loads(lb) Vert: 10=-17(13)11=0(F) a CARL G. FORBES FL LIC. NO 20699 656 S. POMPANO PKWY. PAMPANO BEACH,FL. 33069 (964)692-6651 Job Truss Truss Type Qty Ply BRUZZI RES 161116 J 1 Corner Jack 1 1 Jo Terence(optional) Cuslom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18'2(Y16 MiTek Industries,Inc. Thu Jul 20 14:25:35 2017 Page 1 10-111i:knKb04ep9836JxrasWFrzgf�tt�J-V9auvgR6hAcVBywRy3gnfZeE2Yz0ERXzYtP_Xgyw9ZU 0-9-10 1-1- 1-2-0 I 0-9-10 0-3-8 ' Scale=1:9.7 3 7.25 12 0 2 r T1 B1 >< 4 1 3x4= 10-1-1 10-1-1 10-8-2 0-3-8 1-1-2 • • 0-9-10 1 • • •••• •••••• LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft L/d PLATL'S •GRIP • TCLL 30.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 7 >999 360 •• :•• MT20 •• X244/190 •••••• TCDL 15.0 Lumber DOL 1.25 BC 0.05 Vert(TL) 0.00 7 >999 240 •• 000 • • • BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a • •• •••• :••••; BCDL 10.0 Code FBC2014/TP12007 Matrix-MP Wind(LL) -0.00 7 >999 240 •• •••Weight 6Jq•• FT=JQ%•• LUMBER- BRACING- •••••• • • ••••• TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathiml directly applied �{y1�oc pu4ips.••• BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly aP011egp610-0-0 oc braking. • MiTek recommends tTt St%bi:zers ano requijed cross braking be installed during truss erection,in aceardwce with Stab�i1jig • Installation guide. 0 • • ' • • REACTIONS. (Ib/size) 3=9/Mechanical,2=237/0-8-0 (min.0-1-8),4=-15/Mechanical ••• . ••• • ;'"•. Max Horz2=133(LC 12) • • Max Uplift3=-9(LC 9),2=-228(LC 12),4=-15(LC 1) •• Max Grav3=15(LC 8),2=237(LC 1),4=44(LC 12) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/58,2-3=-24/38 BOT CHORD 2-4=0/0 NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf;h=25ft,B=45ft;L=24ft;eave=4ft;Cat.II;Exp C;Encl.,GCpi=0.18;MWFRS (directional)and C-C Exterior(2)zone;C-C for members and forces&MWFRS for reactions shown,Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 9 Ib uplift at joint 3,228 Ib uplift at joint 2 and 15 Ib uplift at joint 4. 6)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard CARL G. FORBES FL LIC. NO: 20699 666 S. POMPANO PKWY. PAMPAN O BEACH,FL. 33069 (954)682.6651 Job Truss Truss Type Ply BRUZZI RES 161116 J2 Corner Jack 11 1 Job Reference(optional) + Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 2016 MiTek Industries,Inc. Thu Jul 20 14:25:36 2017 Page 1 100-3 ID:knKbO4ep9836JxrasWFrzJyRtuJ-zL8G7ASkSUkMp6VdWmLOCm CRpyVizun6nX9X46yw9ZT } i -1-2-0 2-9-11 - - 1-2-0 -- 2-9-11 Scale=1:8.6 3 2.77 F12 i n 2 4 Ti ro W a d 1 B1 4 r 1 10-0-3 3x4= 10-0-3 �0�✓:11 0-3-8 3-1-3 • -r•-L• •••••• Plate Offsets(X,Y)-- [2:0-3-1,Edge] .. . •• • • LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d • :••PLATES *GRIP •••••• TCLL 30.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) -0.00 7 >999 360 •• •••MT20 ) • 244/190 •••• TCDL 15.0 Lumber DOL 1.25 BC 0.15 Vert(TL) -0.01 4-7 >999 240 • •• *fee • • BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a • • • • BCDL 10.0 Code FBC2014/TP12007 Matrix-MP Wind(LL) 0.01 4-7 >999 240 • • Weight:11 Ib FT=200 0°Y*• • •• ••• • • ••••• • • • • • LUMBER- BRACING- •• •• •• •• •••••• TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathipa dilill applied or 3-1-3 oc purlins.•• BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied Sr 10-0-0 oc bracin�q. • �•�. MiTek recommends that Stabilizers and oegsiped cross bracing- be installed during trues erepTpn,in acEordance with StIllIyl"r• Installation guide. •• • ••• • • • REACTIONS. (Ib/size) 3=98/Mechanical,2=296/0-8-0 (min.0-1-8),4=48/Mechanical • Max Horz 2=94(LC 8) Max Uplift3=-67(LC 8),2=-242(LC 8),4=-7(LC 8) Max Grav3=98(LC 1),2=296(LC 1),4=53(LC 3) FORCES. (Ib)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/24,2-3=-50/22 BOT CHORD 2-4=0/0 NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=8.Opsf;BCDL=4.Opsf,h=25ft;B=45ft;L=24ft;eave=4ft,Cat.II;Exp C;Encl.,GCpi=0.18;MWFRS (directional)and C-C Corner(3)zone;C-C for members and forces&MWFRS for reactions shown,Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 67 Ib uplift at joint 3,242 Ib uplift at joint 2 and 7 Ib uplift at joint 4. 6)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard CARL. Q. FORBES FL. LIC. Nth. 20699 566 S.POMPANO PKWY.. PAMPANO MACH,FL. 33069 (964)682-6651 Job Truss Truss Type Qty Ply BRUZZI RES 101116 J3 Corner Jack 1 1 Job Reference(optional) Custom Truss,Delray Beach,FL 33444,Company Run:8.020 s Nov 18 2016 Print:8.020 s Nov 18 20161 MiTek Industries,Inc. Thu Jul 20 14:25:37 2017 Page 1 t0-11 ID:knKbO4ep9836JxrasWFrzJyR J-RXheKWTMDnsDQG4g4UsFk_jaXMeeiLIGOBu4cZyw9ZS -1-2-0 1-8-0 1-113 -2=7 1-20 — 180 81 1 Scale=1:12.6 3 7.25 F12 + u) f1 2 + v�' Bi cd�1l 4 1 2x4= 4 10-1-1 1 10-1-1 11-2-7 *000 10-3-8 1-11-8 __� • • �••••� 0000•• 0-3-8 1-8-0 • Plate Offsets(X,Y)-- [2:0-1-4,0-1-11 •• • •• • • •• ••• •• • 0000•• LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud • PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.00 7 >999 360 " MT20 • 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.11 Vert(TL) -0.00 7 >999 240 • ••00000 • • BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a 0000 0 a 0 0 0 0• BCDL 10.0 Code FBC2014/TPI2007 Matrix-MP Wind(LL) -0.00 7 >999 240 Weight:9 Ib FT=20% • 0000•0 • 0 •• LUMBER- BRACING- *00000 •• •• •••••• TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheath".di %4y applied or J-11-8 oc purling• BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly apylied4or!0-0-0 oc bracing. • MiTek recommends that Stabilizers andeegaired cross bracing be installed during truss erpapn,in ac ordance with SftlyQg Installation guide. •• • 000 • • • REACTIONS. (Ib/size) 3=55/Mechanical,2=255/0-8-0 (min.0-1-8),4=15/Mechanical . Max Horz 2=172(LC 12) Max Uplift3=-39(LC 12),2=-195(LC 12) t Max Grav3=65(LC 17),2=255(LC 1),4=31(LC 3) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0158,2-3=-51/61 BOT CHORD 2-4=0/0 NOTES- 1)Wind:ASCE 7-10;Vult=175mph(3-second gust)Vasd=136mph;TCDL=B.Opsf;BCDL=4.Opsf;h=25ft;6=45ft;L=24ft;eave=4ft;Cat.II;Exp C;Encl.,GCpi=0.18;MWFRS (directional)and C-C Exterior(2)zone;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 39 Ib uplift at joint 3 and 195 Ib uplift at joint 2. 6)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard t CARL G. FOR ES FL LIC. NO: 20699 555 S. POMPANO PKWY. P,AMPANO BEACH, FL. 33069 (954)682-6651 + 'r TABLE OF CONTENTS 1 GENERAL STANDARD.ENGINEERING PAGES 1....LATEAAL BRACING RECOMMENDATIONS................... ST-STRGBCK 1 2...WEB BRACING RECOMMENDATIONS....................:.......ST-WEBBRACE 3...TRUSS WEB BRACING LETTER 4...SCAB—BRACE DETAIL... 5... T—BRACE/I—BRACE DETAIL W/2X BRACE ONLY..............ST—T—BRACE 2 r. 6...L—BRACE DETAIL............. . 0000... ............................. ;.ST—L BRAC ••.• • •E 0000 000000 • • • . •• • •• . • 7....OPEN.TACK& CORNER HIP RAFTER DETAIL.................ST-CORNFA.-SET 0•.•-• ••••:• 0000.. ..•• 8...LATERAL TOE-NAIL DETAIL........................................ST-TOE1� -0000' 00000 r-----• 00 0 - ---• 9...UPLIFT TOE-NAIL DETAIL...........................................ST-TOEM AIT.,•-UPLIFT,•• •••••• •.••.• x • 0 • • ",k - 000000 .1 10...LATERAL TOE-NAIL DETAIL.......................................ST-TOENAIL :••••• :0000: 006,o 0- - • •0 11...TRUSSED VALLEY SET DETAIL....................................ST—VALLEY3 , 12...STANDARD PIGGYBACK TRUSS CONNECTION DETAIL..ST—PIGGY—ALT 13...STANDARD PIGGYBACK TRUSS CONNECTION DETAIL (PERPENDICULAR) e 14...STANDARD GABLE END DETAIL..................................ST—GE170—SP 15...STANDARD GABLE END DETAIL..................................ST—GE170—D—SP 16...STANDARD GABLE END DETAIL..................................SHEET 2 L 17...BEARING BLOCK DETAIL..........:'............................... ST—BLCK1 18...BEARING BLOCK DETAIL'............................................ST—BLCK2 CARL G. FORMES,PE 555 S.POMPANO PKWY POMPANO BEACH, FL;3069 ` LICENSE NO.:2069%, *' : f (954)682-6651'..-/" . E .---_—_........... ....._... _._......_....; Symbols Numbering Systern I A General Safety No " PLATE LOCATION AND ORIENTATION I 3 Center plate on joint unless x,y I Failure to Follow Could Cause Proper#y -y; ,-, /4 offsets ore indicated. I 6-4-8 dimensions shown in ft-in-sixteenths i Damage or Personal Injury i Dimensions ore in ft-in-sixteenths: (Drawings not to stole) Apply plates to both sides of truss i 1. Additional stability bracing for truss system,e.g. and fully embed teeth: diagonal or X-brocing.is always required. See BCS(. i 2. Truss brocing must be designed by an engineer.For 2 3 I wide truss spacing,individual lateral braces themselves ITOP CHORDS ! may require bracing,or alternative T,I.or Ekmino for I T c;2 C2-3 1 brocing should be considered. 4 3. Never exceed the design loading shown and never o WEBS c� I stack materials on inadequately braced trusses. D I Iu 4/� 3 �`�, O 1 4. Provide copies of this truss design to the building 1 - For 4 x 2 orientation,locate U ve = l designer,erection supervisor,property owner and plates 0-'r;i'from outside o- u U 1 aNother Interested parties. i edge of truss. 0 cr a co-r cse O 1 S. Cut members to bear tightly against each other. BOTTOM CHORDS 6. Place plates on each face of truss at each This symbol indicates the 8 - 7 6 5 joint and embed fully.Knots and wone at joint required direction of slots in locations ore regulated by ANSI/TPI 1. connector plates. 7. Design assumes trusses will be suitably protected from I `Plate location details available in MiTek 20/20 the environment in accord with ANSI/TPI 1. l software or upon request. 8. Unless otherwise noted,moisture content of lumber -JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE shop not exceed 19%at time of fabrication. _ AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. 1 9. Unless expressly noted,this design is not opplcable for PLATE SIZE use with fire retardant,preservative treated.or green lumber. The first dimension is theP late CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 10.Comber is anon-shucturol consideration and is the I I /� v 4 width measured perpendicular NUMBERS/LETTERS. responsibirity of truss tabricoior.General practice is to —r /� to slots.Second dimension is 1 comber for dead bad deflection. the length parallel to slots. 1 11.Plate type,she,orientation and location dimensions LATERAL BRACING LOCATION PRODUCTCODE APPROVALS I indicated are minimum plating requirements. I ICC-ES Reports: 12.lumber used shall be of the species and size,and In of respects,equal to or better than that 1 Indicated by symbol shown and/or ESR-1311,ESR-1352,ER-5243,96048, specified.I 'r by text in the bracing section of the 95-43,96-31,-9667A 13.toll chords must be sheathed or purlins provided at I output. Use T,I or Eliminator bracing NER-487,NER-561 f spacing indicated on design. if indicated. 95110,84-32,96-67,ER-3907,9432A 14.Bottom chords require lateral bracing at 101t.spacing, BEARING or less,if no ceiling is installed,unless otherwise noted. —1 _ T T -•• : _• •_ _ • • 000 •• __ T T IS.Connections not shown,ore the responsibility of others. I Indicates location where bearings $ : : : : :•• : •1 ••• • • • • •• • 1 16.Do not cul or alter truss member or plate without prior — (supports)occur. Icons vary but • . . • • . • •p 2006 MiTek®All Rights Reserved 1 approval of an engineer. reaction section indicates joint •: • • •• ••• • + - number where bearings occur. i 17.Install and load vertically unless indicated otherwise. i 18.Use of green or treated lumber may pose unacceptable ••• •• ••• ••• j environmental,health or performance risks.Consult with • • ► • • • • project engineer before use. Industry Standards: • • I • • • • • ANSI/TPI1: National Design Specification for Metal•• •• ••• •• 19.Review all portions of this design(front,bock,words 1 Plate Connected Wood Truss Construction. i a T. i and pictures)before use.Reviewing pictures alone DS8-89: Design Standard for Bracing. I i isnot sufficient. BCSI: Building Component Safely Information, • ITek • *00 • 01i_20.Design assumes manufacture in accordance wilh ?' Guide to Good Practice for Handling, • ,• • • r,17WZV. 2'p PZRFG7RM.' I ANSI/TPI I Quolty Criteria. 1 Installing 8,Bracing of Metal Plate `• ; ; ;• * • • • I i Connected Wood Trusses. •.� •• •MiTak Is}ng , e4ma Reference Sheet:Mll-7473 rev, 10-'08 I • —_—;---'_--_.._.-__.__..___--._._—Tom_.--__.—__—_____.-- .�..__— —FEBRUARY 8, 2008 I LATERAL BRACINGRECOMMENDATIONS ST-STRGBCK _............... MiTek USA,*Inc. Page 1 of 1 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS _-i I 12 "STRONGBACK" IS RECOMMENDED, LOCATED EVERY 8 TO'10 FEET ! i MiTel(USA, Inc. I ALONG A FLOOR TRUSS. j 4 � NOTE 1:2X6 STRONGBACK ORIENTED VERTICALLY-MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY j ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO-THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. I NOTE 2:STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF i THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR,AND PROPERLY CONNECTED,BY OTHERS, AT THE ENDS. � ATTACH TO VERTICAL USE METAL FRAMING ATTACH TO VERTICAL INSERT WOOD SCREW THROUGH OUTSIDE ANCHOR TO ATTACH WEB WITH(3)-10d NAILS SCAB WITH(3)-i0d NAILS FACE OF CHORD INTO EDGE OF STRONGBACK(0.131"x 3") 4 TO TOP CHORD\ (0.131"x 3") (DO NOT USE DRYWALL TYPE SCREWS) I _ r ATTACH TO VERTICAL I` WEB WITH(3);=10d NAILS i t _ / (0.131"x X) • • t --•__._—• -- �, •••• 0••000 ••••.i• 1 i ••ease • • • I BLOCKING BEHIND THE ��—�• ` •*so.• ATTACH 2x4 VERTICAL Tb ••• *ease • • VERTICAL WEB IS FACE • • � `RECOMMENDED WHILE OF TRUSS. FASTEN TO TOP AND ATTA% Q J:AORD sea• *0000 NAILING THE STRONGBACK BOTTOM,CHORD WITH(2)-10d WITH tE12x 3" • • NAILS(0.131"x 3")IN EACH CHORD WOOD3aOFl"S(.216"8IAjv1.): ••••• I, 00 00 so �/ I / a • • } • • ` so USE METAL FRAMING I ANCHOR TO ATTACH ATTACH TO VERTICAL ATTACH TO VERTICAL INSERT SCREW THROUGH OUTSIDE TO BOTTOM CHORD WEB WITH(3)-10d NAILS SCAB WITH(3)-10d NAILS FACE OF CHORD INTO EDGE (0.131"x 3") (0.131"x 3") STRONG ACK(DO NOT USE OF I "DRYWALL TYPE SCREWS) � I 4-0-0 TRUSS 2i6 0I WALL BLOCKING ACK I I STRONGB T-- — I (TYPICAL SPLICE) � (BY OTHERS) (BY OTHERS) Ll THE STRONGBACKS SHALL BE SECURED A7 THEIR ENDS TO ADEQUATE'SUPPORT, + DESIGNED BY OTHERS. IF SPLICING IS NECESSARY;USE A 4'-0"LONG j SCAB CENTERED ON THE SPLICE AND JOINED WITH(12)-10d NAILS I (0.131"x 3")EQUALLY SPACED. r ALTERNATE METHOD OF SPLICING: I OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0"AND FASTEN WITH(12)-10d NAILS(0.131"x 3")STAGGERED AND EQUALLY SPACED. (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL) A + I i o I � i 1 i ` MARCH 12, 2009 I WEB BRA'CING'RECOMMENDATIONS , ST-WEBBRACE MiTek USA,Inc. Page 1 of 1 MAXIMUM TRUSS WEB F=ORCE(Ibs.)(See note 7) BRACE BAY SIZE 24"O.C.' 48"O.C. 72"O.C. BRACING MATERIAL TYPE BRACING MATERIAL TYPE BRACING MATERIAL TYPE MiTek USA,Inc. A B C D A B' C D C I D 10'-0' 188 ,•y'i.^ '':i.i ".'r.::j',r"• 1610 1666 6 2829 n+-`•.C, L• i'_'d .l 1... _• ;,F;� '�•':� i"'�;rw �...•'. ''.j.:''� �'.: 1.i.�.' 12'-0' 1342 1572 1572 2358 'i:; 3143 #µ3143 4715 4715 7074 � 14'-0' I 1150 .1347 1347 2021;,#`;y:; ,;:-`•-- ��,•' -:*'°".'...'` 16'-0' 1006 1179 1179 -1768 _ -i 2358 2358 3536 y18-0 1048 1048 1572"x ~' •3143•• 4715894 20'-0'r 805 943 943 1414 1886, 1886 2829 it'' Bay size shall be measured in between the centers of pairs of diagonals. GENERAL NOTES TYPE BRACING MATERIALS 1.OUGONAL BRACING IS REOUIRED TO TRANSFER THE CUMULATIVE LATERAL BRACE FORCE INTO THE , 0000 ,ROOF ANDIOR CEILING DIAPHRAGM.THE DIAPHRAGM IS TO BE DESIGNED BY A OUALIRED • • PROFESSIONAL. I i i •••• • ' •••• 1 X 4 1%4%SPS a 2.THESE CALCULATIONS ARE BASED ON LATERAL.BRACE CARRYING 2%OF THE WEB FORCE. r • - • A 00000 4pR.•• .3.'DIAGONAL BRACING MATERIAL MUST BE SAME SIZE AND GRADE OR BETTER,AS THE LATERAL BRACE • • i MATERIAL:AND SHALL BE INSTALLED N SUCH A MANNER THAT R INTERSECTS WEB MEMBERS •••• • • M 6(4 H2 SRBIRW:",9PF) AT APPROX.45 DEGREES AND SHALL BE NAILED AT EACH END AND EACH INTERMEDIATE TRUSS WITH 2-5d •• (0.131.4_"FOR 1 a4 BRACES,2.1 Od(DAMN 3")FOR 2;0 and 20 BRACES.AND 3.10d(0.131'O)FOR 2.6 BRACES. • �"""'- ""'•"""""--"'--'---'��'•`•"'•j�--'•-•- -""`-^----'-•--'-- 4. CONNECT LATERAL BRACE TO EACH TRUSS WITH 2.6d(0.131'X2.5)NAILS FOR 1x4 LATERAL BRACES. •••• • 2.10d(0.131*4")NAILS FOR 20 and 2A LATERAL BRACES.AND 3.104(0.131.01 FOR 2,6 LATERAL BRACES. • • Bf+611�,�STD,COt�Stt*,pF,HF,OR SP) 5.`LATERAL BRACE SHOULD BE CONTINUOUS AND SHOULD OVERLAP AT LEAST ONE TRUSS SPACE "•••• FOR CONTINUITY.:, '1 ••• L__ !� "" - 6.'FOR AODRIDNAL GUIDANCE REGARDING DESIGN AND W STALLATION OF BRACING.CONSULT 00:40 C •2 X•4 nS,�TD,COIVt41,10F,HF,OR SP) DSB-59 TEMPORARY BRACING OF METAL PLATE CONNECTED WOOD TRUSSES AND SCSI 1 • GUIDE TO GOOD PRACTICE FOR RANDLNG,INSTALLING t BRACING OF METAL PLATE CONNECTED •••• �,•,____ •�_ •a ••. •• WOOD TRUSSES,JOINTLY PRODUCED BY WOOD TRUSS COUNCIL OF AMERICA and TRUSS PLATE INST rUTE. • .._ _-._..__..-_._._.L.._.___---'—__ ____..._ ~a.sbOlndlatry.eom and www.I*WLorO • • D 12)ft 43 OR BETTY(:F�*12:,HF,OR SP) 7. REFER TO SPECIFIC TRUSS DESIGN DRAWING FOR WEB MEMBER FORCE. •••••• • • • '• 8. TABULATED VALUES ARE BASED ON A DOL_ 1.15 • GOR STABILIZERS: • • •••••NOR A SPACING OF�2�'Q.C.ONLY, IT81&hILIZER•TRUSS BRACING SYSTEMS CAN BE • a185TITUTL41 FOR�(TPE A,B,C A D BRACING MATERIAL DIAGONAL BRACING FOR STABILIZERS ARE TO BE PLONDEO AT BAY SIZE INDICATED ABOVE.WHERE DIAPHRAGM BRACING IS REOUIRED I AT PITCH B1k*S,STABILIZERS MAY BE REPLACED WITH WOOD BLOCKING:SEE-STABILIZER',; TRUSS BRACING INSTALLATION GUIDE AND PRODUCT SPECIFICATION. . r DIAGONAL BRACE �'� \\ •.�� A CONTINUOUS LATERAL ` /,r// I-�, '\•_ 1 \ / _.-__-- ___RESTRAINT 2-10d NAILS ,r• 1✓' • i r /i'���� `�� L �� I (SEE NOTE 4) i TRUSS WEB MEMBERS ' This information is provided as a recommendation to assist in the requirement for permanent bracing of the individual truss web members.Additional bracing may still be required for the stability I of the overall root system.The method shown here is just one y method that can be used to provide stability against web buckling. F 1 0. I fll 4. t t CARL.;G ;FORBES--',P.E. 555 S. POMPANO PARKWAY POMPANO BEACH, FL 33069 FL. LICENSE NO. 20699 ! (954) 682-6651 March 16, 2016 Al To who it may concern: i 0000 Re: TRUSS WEB BRACING .. X0•0••• •••••• . CUSTOM TRUSS- . . 000.96 99 9 0000.. 999999. {'',_ • For any of the trusses designed by this office, where l x4 lateral bracingri,-called for-o"she Vo": engineering sheets, the following may be substituted: '••• •••• •• • 0000.. "• 0000. 9. 99.9 If one brace is called for,.lx4 "T" or"I", Henn Fir or Southern-Yellow);e.ivay be uVwith.. 8d nails at 8 inches o.c. 0000:. 0000.. ' If two braces are called for, 2x4 "T" or"I" Hem Fir or Southern Yellow Vine may06e used with • 12d nails at 8 inches o.c. t In all cased, the "T"or"I" brace must be installed and centered along at least 90% of the,length of the web. Please let me know if I can be of any further assistance. r Very.;truly yours, , ?` Carl G. Forbes, P.E. License•�o:20699 , , r ti. I , t � • r } • t JANUARY 1, 2009 'SCAB-BRACE DETAIL ST - SCAB-BRACE,t MiTek USA,Inc. Page 1 of 1 Note:Scab-Bracing,to'be used when continuous � ----- =�=t lateral bracing at midpoint(or T-Brace) is + r (� �J� �I impractical. L---.-J�/I ------1�---- Scab must cover full length of web+/- MiTek USA,Inc. ' t *'THIS DETAIL IS NOT APLICABLE WHEN BRACING IS '** ' REQUIRED AT 1/3 POINTS OR I-BRACE IS SPECIFIED. p ' APPLY 2x SCAB TO ONE FACE OF WEB WITH 2 ROWS OF 10d(3"X 0.131")NAILS SPACED 6"O.C. - SCAB MUST BE THE SAME GRADE,.SIZE AND l SPECIES(OR BETTER)AS THE WEB. ' t • • •••• •••• • c t • • • • MAXIMUM WEB AXIAL FORCE=2500 lbs •••• ••• :••• MAXIMUM WEB LENGTH= 12'-0" • • 2x4 MINIMUM WEB SIZE • SCAB BRACE MINIMUM WEB GRADE OF#3 • • ' ' 00 sees 0. ••••t• • • • • • •••• • 960 0 :0064: 00 0 \ r; •• / 3 1 \ \ \ i Nails Section Detail \\�\ �-�— Scab-Brace Web Scab-Brace must be same species grade(or better)as web member. t i r August 10, 2010 T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY ST - T-BRACE 2 , ' f�0 R ' 1 MiTek USA,Inc. Page 1 of 1( IV r Note:T-Bracing/I-Bracing to be used when continuous lateral bracing =—, is impractical.T-Brace/I-Brace'must cover 90%of web length. I _-VL-- ]II-D Note:This detail NOT to be used to convert T-Brace/I-Brace I MiTek USA,Inc. r webs to continuous lateral braced webs`- MiTek -------------- ---- . __._. Nailing PatternBrace Size --_-- -----------_---- T-Brace size -Nail Size_ Nail Spacing -- -- for One-Ply Truss'` Y 2x4 or 2x6 or 2x8 10d { 6"o.c, Specified Continuous — ------- ----, --- - -- Rows of Lateral Bracing Note:Nail along entire`length of T-Brace/I-Brace Web-Size 1 - — 2 (On Two-Ply's Nail to Both Plies) - 2x3'or 2x4 2x4 T-Brace 2x4 I-Brace 2x6 2x6 T-Brace _2x6 l-Brace 2x8 2x8 T-Brace 2x81-Brace • '7 I •••••• •••• �•� Nails - • ••0 Brace Size • •• •• •• for Two-Ply Truss f • •••• •• �, pecified Continuous •.•. *000 ••• NV- Rows of Lateral Bracing �••:•• • • ••. a SPACING t ---- — -------- -- ------ • • Web Size 1 2 • .... • • • � � 2x3 or 2x4 2x4 T-Brace 2x4 I-Brace • •• WEA • i • k 2X6 2x6 T-Brace 2x6 I_Brace •••••• .� �- 2x8 2x8 T-Brace ••• k 2x8 I-Brace � -A T-Brace/I-Brace must be same species T-BRACE and grade(or better)as web member. Nails Section,Detail , T-Brace Web Nails Web---- -Brace I I Nailsz i i � ti r JANUARY 1;2009 L-BRACE DETAIL ST - L-BRACE MiTek USA,Inc. Page 1 of 1 Fill Pf L--_J. I.--- 0 MiTek USA,Inc. — --- -----'-----_-----_— I ; Nailing Pattern Note: L-Bracing to be used when continuous i� L-Brace size Nail Size Nail Spacing lateral bracing is impractical.L-brace I '— 1x4 or 6 - 10d — _ 8"o.c. , must cover g0%of web length. 1 12x4,6,or 8 16d 8"D.C. Note:Nail along entire length of L-Brace L-Brace Size ii (On Two-Ply's Nail to Both Plies) for One-Ply Truss I' Specified Continuous Rows of Lateral Bracing Web Size 1 •2•• I ---- • + ..•• I ..•..- /Nails 2x3 or 2x4 �} • A--_ —aa •---7 • 2X6 ••1•H6•• •i�•6• 0000 • r a i 2X8 •.2 "."• • f • DIRECT SUBSTITUTION N(%4P"CABLE. •••••• ••••F SPACING 00.60•, . • ••�• • " •• •6 6•0••i •61• • � •6666• <A • • • • 6 WEB --- •66••6 • • • •• Ar L-grace sMS 0 ; • I • for Two-Ply Trus.• t % L-BRACE E Specified Continuous Rows of Lateral Bracing Web Size 1 2 \\ 2x3 or 2x4 2x4 2x6 2x6 2x8 DIRECT SUBSTITUTION NOT APLICABLE. Nails / Section Detail \ r ----- L-Brace I n Web � ryi � t I I L-Brace must be same species grade (or better)as web member. 4 - { i - 1 JANUARY 22, 2013 OPEN JACK AND CORNER ST-CORNER SET HIP CORNER DETAIL. 0� ® MiTek USA,Inc. Page 1 of 1 FV-100� 0 00 0 00 MiTek USA,Inc. sQUARE cur Connection at D_ Connection at A "Connection at C Conned top of comer Hip with(3)10d(0.131"x3') A 3mvew SMEvew toenails into top chord of hip girder. Open End Jack r ?1VU PITCH I B NEAR SIDE NEAR SIDE MAX 8.00 12 - FAR SIDE FAR SIDE MIN 4.00[12 NEM SIDE NEARSIDE 3x4= C a 0.00' HI of L SPAN(8-0-0 MAX) I Hip Girder Max.overher'!2-at• L ••• •• 0000•• 'HipCbmer • • •• •0000• D 000000 PITCH • Attach 12"2x6 (0. No.2 block with •••••• 10d(0.131"x 3")nails two rows of 10d(0.131'x 3") •••• MAS s.e6 12 nails spaced 3"oc.Use a • • �� 12 •••• min 3"member end distance •••• 0,111.0 Plate covers r *90:6 • 0000• ••••• • • • • t-1/2"min. • • •• •Wer b8andn ' 0000•• •• 3x10= 9 • • I SPAN4•i1o3►11 AMAX) • • I • • 45 DEGREE ANGLE 646,611.heel h.1% 0-1069 BEVEL CUT • M9k.Overhang:2-10-0• • ; Connection at B •000.0 0 00 + SIDE NEW (24) 2 NARS -TYPICAL CORNER FRAMING W — 2'OC TRUSSES -1 HIP GIRD& Or N-80. 45.00 I coop); A LJ2 I �I 10d(0.131"x 3")nails I _ Wood loading: B�P) o Basic wind speed is 170 MPH-ASCE 7-10 Exposure catagory B or C. Y Occupancy category II 1 ¢ 8 psf top chord dead load. 4.2 psf bottom chord dead load. 1 z 25'roof height. Lu MWFRS Directional/C-C Hybrid z Enclosed building(Coed.1) Lu 0 Duration of load is 1.60 — — — — — — — — — — Deflection: ' Truss LL-L/360 TL-IJ240 Lumber.SPF MSR 2100 1.8E min.top chord required for Loading:Duration of load is 1.25 top chord slopes between 5.01/12 and 8/12. 30 psf top chord live load SPF No.2 min.top chord slopes between 5/12 and 4/12. 15 psf top chord deal load SPF No.2 min.bottom chord. 0 psf bottom chord live load SYP No.2 or better for comer rafter. 10 psf bottom chord dead load 10 psf non-concurrent bottom chord live load Plates:All plates are MT20 Installed on each face per TPI 1. Conforms to:IRC 2000/2003/2006/2009/2012 IBC 2000/200312006/2009/2012 j March 4, 2013 LATERAL TOE-NAIL DETAIL, ST-TOENAIL U Mitek USA,Inc. Page 1 of 1. DD I NOTES: 1.TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER ---- �� AND STARTED 113 THE LENGTH OF.THE NAIL FROM THE MEMBER END AS SHOWN. 2.THE END DISTANCE,EDGE,DISTANCE,AND SPACING OF,NAILS SHALL BE SUCH AS TO AVOID UNUSUAL`SPLITTING O yHE WOOD. U 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE BOTTOM CHORD SPECIES_ L MiTek USA,Inc. FOR MEMBERS OF DIFFERENT SPECIES. ) ' SQUARE CUT IIT( E NAIL SINGLE SHEAR VALUES PER NDS 2005(Ib/nail) SII(D;VIEW SLIDE VIEW DIAM. SP DF HF - SPF SPF-S 3 NAILS -- - 2 NAILS z _131 - 88_1-- 80.6 - 69.9 68.4 59.7 NEAR SIDE NEAR SIDE O :135 - -93.5 85.6_ 74.2 72.6 _63.4 ____I FAR SIDE Zr) _ .162-118,3 - -108.3 i 93.9 91.9 802 NEAR SIDE i' --i FAR SIDE C6, _ _-�------ -- - - -- C7 1 .128 84.1 76.9 66.7 65.3 57.0 SIDE VIEW Z (2x6) 0 -_;131_.-_88.1 80.6_ 69_.9 _ 68.4 59.7 4 NAILS N 148 106.6 97.6 --84.7 82.8 72.3 -� NEAR SIDE i t' C6 - - ----� FAR SIDE C7 , .120_ 73.9 67.§..-.--. _58.7_- 57.4 _ _50.1 NEAR SIDE' •••• O .128 84.1-_-_ -76.9 1 66.7' -- -65.3 57.0_ • •••i•• 0000•• 0 131 88.1 80.6 69.9 68.4 59.7 - FAF;SIDFO : •• • •• c • CO . 0000•• 146 106.6 97.6 84.7 82.8 72:3 0000• 0000•• •0000 0..000 VALUES SHOWN ARE CAPACITY PER TOE-NAIL. •••• 00000 • 0 APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. oAO�• •0,000 ••:••• EXAMPLE: ••.t• • • 00000 (3)=16d NAILS(.162"diam.x 3.5")WITH SPF SPECIES BOTTOM CHORD ` 00 000 0••0.0 •••••• • For load duration increase of 1.15: t • •••• ' 0• 3(nails)X 91.9(lb/nail)X 1.15(DOL)=317.0 Ib Maximum Capacity • L •0 -: ` • • •••••' 0000•• ' • • • We, .. • 70 45 DEGREE ANGLE , BEVEL CUT I . SIDE VIEW (2x3) 2 NAILS--_- NEAR SIDE N NEAR SIDE I 00° et \ 45.00' \ U2 2� SIDE VIEW SIDE VIEW , \ (2x4) (2x6) i U2\y i l - 3 NAILS ---- 4 NAILS ) I - \ \ i NEAR SIDE.- NEAR SIDE NEAR SIDE • � ` ,, NEAR SIDE � - - -NEAR SIDE- NEAR SIDE ' -- t " NEAR SIDE r I VIEWS SHOWN ARE FOR 1 ILLUSTRATION PURPOSES ONLY f 4 1 2 ' a IE -March 4, 2013 UPLIFT TOE-NAIL DETAIL ST-TOENAIL_UPLIFTI �\n�� ® MiTek USA,Inc. Page 1 of 1 L�J�� THIS DETAIL SHALL BE USED FOR A'CONNECTION RESISTING UPLIFT FORCES ONLY.BUILDING,DESIGNER IS RESPONSIBLE E=[:] FOR LOADS IN OTHER DIRECTIONS. MiTek USA,Inc. END VIEW SIDE VIEW _0.00^ / OF W LL 1"FOR 3"NAIL TOP PLATE NEAR SIDE r � � 1-1/16"FOR 3.25"NAIL NEAR SIDE L 1-3/16"FOR 3.5"NAIL • • • • • •' — • ••• VIEWS SHOWN ARE FOR •••••FAR SIDE ••••• ILLUSTRATION PURPOSES ONLY • • •••• � 0000 00000 • • • ••�• 0000 •••••• Tb&NAIL W ITI•WIPAL VALUES PER NDS 2005(lb/nail) •• DIV. SP DF HF SPF SPF-S • -- — --- — NOTES: 0000 • • 30 20 • • O �13��: 60 8 33 30— 20 1.TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES ••. _j — g— WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE • • ;,, • 16e* „72 ; • 38 39 37 25 NAIL FROM THE MEMBER END AS SHOWN- vi —" 2.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING F z .128 _ 54 —42 2D 27 19 OF THE WOOD. W .131 55 — 43 _ 29 28 _19_ 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH J LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN IN .148 62 48 34 31 21 THE CONNECTION. z C" 0 _120-- _-51 — 3-___-- _ 27_-----26 ——17-- O .128 —49 _38 26 25 17 .L 0 1131 51 _ 39 27 26 17 .148 57 44 31` 28 20 VALUES SHOWN ARE CAPACITY PER TOE-NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3)-16d NAILS(A 62'diam.x 3.5")WITH SPF SPECIES TOP PLATE For Wind DOL of 1.33: 3(nails)X 37(lb/nail)X 1.33(DOL for wind)=148 ib Maximum Allowable Uplift Reaction Due To Wind For Wind DOL of 1.60: 3(nails)X 37(Ib/nail)X 1.60(DOL for wind)=177 Ib Maximum Allowable Uplift Reaction Due To Wind If the uplift reaction specified on the Truss Design Drawing exceeds 147 lbs(177 lbs)Building Designer is responsible to specifiy a different connection. "'USE(3)TOE-NAILS ON 2x4 BEARING WALL y ""USE(4)TOE-NAILS ON 2x6 BEARING WALL F JANUARY 28, 2015 LATERAL TOE-NAIL DETAIL ST-TOENAIL• SP O17-1 MiTek USA,Inc.l Page 1 of 1 lH� NOTES: L_.._\/-___I�.-J�_-_� 1.TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT.:,(NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. 3. � �l i� l 2.THE END DISTANCE,EDGE,DISTANCE,�AND,SPACING OF NAILS SHALL BE SUCH - �- L AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. MiTek USA;Inc. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES I FOR MEMBERS OF DIFFERENT SPECIES. - 3 _ I THIS DETAIL APPLICABLE TO THEY OE-NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail) THREE END DETAILS SHOWN BELOW DIAM, I SP DF HF SPF SPF-S - 131 88.0 86.6 69.9 68.4' 59.7 -- ----1 4 (p _135 -93.5 _ - 85-.6 .-. 74.2.--__72.6- ___63.4__. VIEWS SHOWN ARE FOR s -- -- -- - --- - ILLUSTRATION PURPOSES ONLY i un -162__ 108.8___._9,9.6 - -86.4 84.5 73.8 -----_-- c1 -- O .128 74.2 67.9 58.9 57.6 50.3 SIDE VIEW Z Y 0 _ .131 75.9 69_5 60.3 59.0 51.1 (2x3) ----- - - - 2 NAILS N .148 81.4 -74.5 c 64.6 63.2 52.5 -------- C6 NEAR SIDE r- VALUES SHOWN ARE CAPACITY PER TOE-NAIL. NEAR SIDE • • APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. •• • •• • • EXAMPLE: •• ' •••• •••••• (3)-16d NAILS(.162"diam.x3.5")WITH SPF SPECIES BOTTOM CHORD 666:69 SIDE VIEW For load duration increase of 1.15: SIDE VIEW •:•• 2x6) 3 •"•'. • �° 3(nails)X 84.5(Ib/nail)X 1.15(DOL)=291.5 Ib Maximum Capacity 2x4) • NAILS ••.• •• •• •••• • • P• • ' NEAR SIDE •NEAR SIp • NEAR SIDE •NEAR SIDE• • • NEAR SIDE • ' • • ••000: ?NEAR$IpF,••• •�TJEAR$)QE . �••••: i F i "k + ANGLE MAY i ANGLE MAY �= VARY FROM ANGLE MAY VARY FROM i 30°TO 60° VARY FROM �\ 30°TO 60° I 30°TO 60° 45.00° _ 45.00° 45:00° �` \ \ )4\ T I w FEBRUARY 14, 2012 TRUSSED VALLEY SET DETAIL ST-VALLEYS �0 ® MiTek USA,Inc. Page 1 of 1 LIVE LOAD'=_30 PSF(MAX)' oo GABLE END,COMMON TRUSS DEAD LOAD' =.15 PSF(MAX) NOTE:VALLEY STUD SPACING NOT OR GIRDER TRUSS 'D.01 INC=•1.15 t. TO EXCEED 48"O.C.SPACING ASCE 7-98,;ASCE 7-02,'ASCE 7-05(MWFRS)100 MPH MiTek USA,Inc. ASCE 7-10(MWFRS)125 MPH --- --- --- --- --- I - II II 11 ❑ ❑ ❑ O 11 111 II I II 11 1j it II li it II 11 II I II .II 11 11 11 II 11 11 II II ,I 11 II 11 11 11 11 II. 11 11 11 II11 II 11 1 I 11 11 11 ,7 11 II Ij II 11 11 II 1� I II jl 11 II II 11 I 1 11 I II I 11 it 1) �j II II• 11 1 1; BASE TRUSSES VALLEY TRUSS TYPICAL TYPICAL(24"O.C.) (24"O.C.) • • VALLEY TRUSS TYPICAL GABLE END,COMMON TRUSS •• • • • 5 (24"O.C.) OR GIRDER TRUSS •1 INSTALL 134$6f P 12 F�IjSSES. ' •• 7 WfLY SHEmrHk1G TO TO?C. i"W OF SUPPORTIN • TR41SSES, V4LEY TRUSS'MAY PROVIDE 6 •BFKCING IF SHEATHING IAS APPLIED. BASE TRU S[3 MUST BE DECiONED FOR v 7 •••M IRLIN SPA"NG EQUIVA%t jT jjO VALLEY i :-FiUSS SPACING(NOT TO EXCtED 24"O.C.). --------- . I STALL\qL6E'?pUSSESt�,MAXIMUM) • ••AND SECURE TO BASE TRU S IPER DETAIL 8 4. BRACE VALLEY WEBS IN� rMOANCE WITH SEE DETAIL •TAE INDIVJ jyjI gESIGN MRAW INGS. A,-B,OR C • • ; 0 . • BELOW(TYP.) 9 .Tl5t-NAII.VA6VY TO ; %.• BASE TRIAP-W/ (2)16d TOE NAILS 12 11 10 ATTACH 2x6 CONTINOUS NO.2 SPF ATTACH 2x4 CONTINOUS'NO.2 SPF TO THE FACE OF THE ROOF W/TWO BLOCK TO THE FACE OF THE ROOF W/ 16d(A 31"x 3.5")NAILS INTO EACH TWO 16d(.131"x 3.5")NAILS INTO EACH TRUSS BELOW TRUSS BELOW. EACH TRUSS BELOW MUST HAVE A BLOCK ATTACHED TO IT. TOE-NAIL VALLEY TO BASE TRUSS W/ VALLEY TRUSS (2)16d TOE NAILS RESTS ON 2x6 DETAIL A (GREATER THAN 3/12 PITCH) DETAIL B ATTACH BEVELED 2x4 CONTINOUS (3/12 PITCH OR LESS) NO.2 SPF TO THE FACE OF THE ROOF W/TWO 16d(.131"x 3.5")NAILS INTO EACH TRUSS BELOW •r �►�ATTACH VALLEY TO BEVELED 2x4 W/ (2)16d TOE NAILS DETAIL C TOE-NAIL VALLEY TO (GREATER THAN 3/12 PITCH BASE TRUSS W/ LESS THAN 12/12 PITCH) (2)16d TOE NAILS L r 1 . STANDARD PIGGYBACK I FEBRUARY 14, 2012 I TRUSS CONNECTION DETAIL ST-PIGGY-ALT MiTek USA,Inc. =D ®, f MAXIMUM WIND SPEED=REFER TO NOTES D AND OR E r— MAX MEAN ROOF HEIGHT=30 FEET MAX TRUSS SPACING'=24"O.C. CATEGORY II BUILDING t ( # EXPOSURE B or C ASCE 7-02,ASCE 7-05 • L 9, " DURATION OF LOAD INCREASE:1.60 t DETAIL IS NOT APPLICABLE FOR TRUSSES MiTek USA,Inc. TRANSFERING DRAG LOADS(SHEAR TRUSSES). ADDITIONAL CONSIDERATIONS BY BUILDING ! ENGINEER/DESIGNER ARE REQUIRED- A i PIGGBACK TRUSS,REFER TO MITEK TRUSS DESIGN DRAWING. SHALL BE CONNECTED TO EACH PURLIN E ,WITH(2)0.131"X 3.5"TOE NAILED. + B-BASE TRUSS,REFER TO MITEK TRUSS DESIGN DRAWING. , C-PURLINS AT EACH BASE TRUSS JOINT AND A MAXIMUM 24"O.C. UNLESS SPECIFIED CLOSER ON MITEK TRUSS DESIGN DRAWING. A r' CONNECT TO BASE TRUSS WITH(2) 0.131'X 3.5"NAILS EACH. :1 D-2 X:'„-X 4'-0'SCAB.SIZE AND GRADE TO MATCH TOP CHORD OF I \ PIGGYBACK TRUSS,ATTACHED TO ONE FACE,CENTERED ON ' INTERSECTION,WITH(2)ROWS OF 0.131”X 3"NAILS @ 4"O.C. SCAB MAY BE OMITTED PROVIDED THE TOP CHORD SHEATHING IS CONTINUOUS OVER INTERSECTION AT LEAST 1 FT.IN BOTH DIRECTIONS AND:/ -1. WIND SPEED OF 90 MPH OR LESS FOR ANY PIGGYBACK SPAN,OR 2.WIND SPEED OF 91 MPH TO 140 MPH WITH A MAXIMUM PIGGYBACK SPAN OF 12 It. I E-FOR WIND SPEED IN THE RANGE 126 MPH-160 MPH C ADD 9"x 9'x 1/2"PLYWOOD(or 7/16"OSB)GUSSET EACH SIDE AT 48"O.C.OR LESS.ATTACH WITH 3--6d(0.113'X2")NAILS INTO EACH CHORD FROM I •• EACH SIDE(TOTAL-12 NAILS) • • •••• • • • 0000 \ 5 �_ 0000 i •• •. • B • •e • ••••s• 00 J.4 D so 000400 ••• •• • 00:4• Geese • • WHEN NO GAP BETWEEN PIGGYBACK AND BASE TRUSS EXISTS: � • •••• REPLACE TOE NAILING OF PIGGYBACK TRUSS TO PURLINS WITH Nail-On • •• • 0904 PLATES AS SHOWN,AND INSTALL PURLINS TO BOTTOM EDGE OF BASE • •• •• ••• • TRUSS TOP CHORD AT SPECIFIED SPACING SHOWN ON BASE TRUSS MITEK DESIGN DRAWING. • • • ' r • ••• •• 0000•• • • • • ••G •• * SCAB CONNECTION PER i \ •• r NOTED ABOVE irlThis sheet is provided as a Piggyback connection detail only.Building Designer is responsible for all 7"x 7"x 1/2"PLYWOOD(or 7/16"OSB)GUSSET EACH SIDE AT 24"O.C.AT permanent bracing per standard engineering practices or\ EACH BASE TRUSS JOINT.ATTACH WITH 3-6d(0.113"X 2")NAILS refer to BCSI for general guidance on lateral restraint INTO EACH CHORD FROM EACH SIDE(TOTAL-12 NAILS) - and diagonal bracing requirements. VERTICAL WEB FOR LARGE CONCENTRATED LOADS APPLIED EXTEND THROUGH BOTTOM CHORD TO CAP TRUSS REQUIRING AYERTICAL WEB: ,. OF PIGGYBACK 1) VERTICAL WEBS OF PIGGYBACK AND BASE TRUSS ` MUST MATCH IN SIZE,GRADE,AND MUST LINE UP AS SHOWN IN DETAIL. \ 2) ATTACH 2 x_x 4'-0"SCAB TO EACH FACE OF TRUSS ASSEMBLY WITH 2 ROWS OF 10d(0.131'X 3")NAILS SPACED 4"O.C.FROM EACH FACE. (SIZE AND GRADE TO MATCH \ VERTICAL WEBS OF PIGGYBACK AND BASE TRUSS.) (MINIMUM 2X4) 3) THIS CONNECTION IS ONLY VALID FOR A MAXIMUM CONCENTRATED LOAD OF4000 LBS(®1.15). REVIEW BY A QUALIFIED ENGINEER'IS REQUIRED FOR LOADS GREATER THAN 4000 LBS. -------------- -- 4) FOR PIGGYBACK TRUSSES CARRYING GIRDER LOADS, NUMBER OF PLYS OF PIGGYBACK TRUSS TO MATCH BASE TRUSS. .' 5) CONCENTRATED LOAD MUST BE APPLIED TO BOTH-, THE PIGGYBACK AND THE BASE TRUSS DtSIGN. L7 i E STANDAR PIGGYBACK TRUSS ST-PIGGY-PERP. FEBRUARY 14,2012 CONNECTION DETAIL(PERPENDICULAR) MITek USA,Inc. Page 1 of 1 -- s MAX MEAN ROOF HEIGHT=30 FEET BUILDING CATEGORY it WIND EXPOSURE B-or C WIND DESIGN PER ASCE 7-98,ASCE 7-02,ASCE 7-05 100 MPH(MW FRS): ; WIND DESIGN,PER A$CE 7-10125 MPH(MWFRS) i M(Tek USA,Inc. DURATION-OF LOAD INCREASE i f 1 FOR WIND LOADS:1.60 DETAIL IS NOT APPLICABLE FOR TRUSSES' i TRANSFERING DRAG LOAD$(SHEAR TRUSSES). ADDITIONAL CONSIDERATIONS BY BUILDING ENGINEER/DESIGNER ARE REQUIRED. THIS DETAIL SHALL BE ONLY USED,FOR RESISTING A VERTICAL-WIND UPLIFT! UP T'p14D{.BS MAXIMUM AT EACH CONNECTION POINT. BUILDING DESIGNl R IS RESPQNSIBLF FOR THE LOAD EXCEEDING THIS LIMITATION AND/OR IN OTHER DIRECTIONS. i • is. IGGY TRUSS • (CROSS-SECfft ViEW10... ATTACH PIGGYBACK TRUSS 1 • ' ••1•Mer to actutil truss des�gr>•dnawing for TO BAST;TRUSS WITH ' adt itionalpkgyMack truss igi%mation, (2)-tsd(0.131-X 3.5-)NAILS i •>•••• sees• r '.••.' TOENAILED. i ! • j SIDE Lr , FAR SIDE i ' :•• • ? NOTES FOR TRUSS: •••t••• _ • ;` 1 ' • —+ - — — 1_ THIS DETAIL IS VALID FOR ONE-PLY PIGGYBACK TRUSS ONLY; • • • �,;.• • • • 2. THE CHORD MEMBER OF PIGGYBACK AND BASE TRUSSES • •I �� MUST BE SOUTHERN.PINE OR DOUGLAS FIR-LARCH LUMBER; s' —r----- ~— = 3. THE SPACING OF PIGGYBACK TRUSSES AND 13ASE TRUSSES � _` IS2FTORLESS; i 4. THE PIGGYBACK TRUSSES SHOULD BE PERPENDICULAR TO BASE TRUSSES. i , I 5. PIGGYBACK TRUSS MAY NOT CANTILEVER OVER BASE TRUSS f OR HAVE AN OVERHANG WHICH WILL CREATE A HIGHER UPLIFT t AT CONNECTING POINT. 1 _. FLAT TOP CHORD OF BASE TRUSS . i BASE TRUSS(SIDE VIEW) Refer to actualtruss design drawing for additional base truss information. ; I - NOTES FOR TOE-NAIL: 1.TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES ' WITH THE MEMBER AND STARTED 113 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF r NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING. , OF THE WOOD. r _ I May 24,2012 Standard Gable End Detail ST-GE170-SP L s _ _ MTek USA,Inc. Page 1 Typical 2x4 L Brace Nailed To 2x4 Verticals W/10d Nails,6"o.c. Vertical Stud rc�----�----�c���• \ ;n Vertical Stud ; \ 2X6 SP OR SPF No.21 .,• - (4)-16d Nails \> DIAGONAL BRACE MiTek USA, Inc. 16d Nails SECTION B-B //- Spaced 6"o.c. DIAGONAL BRACE �i'� ,��` € 4'•0"O.CC.MAX (2)-1 Od Nails into 2x6 l --- —— _ 2X6 SP OR SPF No.2 TRUSS GEOMETRY AND CONDITIONS R i SHOWN ARE FOR ILLUSTRATION ONLY. \Typical Horizontal Brace 12 SECTION A-A �2X4 SP OR SPF No.2 Nailed To 2x4 Verticals I w/(4)-10d Nails i � Varies to Common Truss l �� PROVIDE&4BLOCKING BETWEEN THE FIRST SEE INDIVIDUAL MITEK ENGINEERING 2x TWO TRUSSES AS NOTED. TOENAIL BLOCKING ' / --Ai I _DRAWINGS FOR DESIGN CRITERIA TO TRUSSES WITH(2)-10d NAILS AT EACH END. I I I ** ATTACH DIAGONAL BRACE TO BLOCKING WITH (5)-t Od NAILS. i L I I 3x4- i iy �-----B--- -- --- B"' B (4)-8d NAILS MINIMUM,PLYWOOD �•� SHEATHING TO 2x4 STD SPF BLOCK •• • \• • • •••• •••+• Diagonal Bracing ,�* -L-Bracing Refer • • + • Refer to Section A-A to Section B-B \ •• • •• • • • NOTE: 24"Max Roof Sheathing--, •+•••• ••••• 1.MINIMUM GRADE OF 42 MATERIAL IN THE TOP AND BOTTOM CHORDS. -- • 2.CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND I • • + • WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. _ •• • • 3.BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY.CONSULT BLDG. r 'j/. • • • ~ / •••• ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT 0. (2)-101t'• •' •• • • / / '� •••• BRACING OF ROOF SYSTEM. ��Max_, — �• 2�•10d NAILS 4."L"BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF or SP No.3 % ••• • +• • • ` OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6"O.C. • + 5.DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF I •••• DIAPHRAM AT 4'-0"O.C. •+'• • •••• - 6.CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 ANDA �rUS �• 24n �y 2x4i'AS SHOWN WITH 16d NAILS SPACED 6"O.C.HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. �• Its• + ATTACH TO VERTICAL GABLE STUDS WITH(4)1 Od NAILS THROUGH 2x4. •• (REFER TO SECTION A-A) Diag. Brace 7. GABLE STUD DEFLECTION MEETS OR EXCEEDS U240. at 1/3 OIr1tS 2x6 DIAGONAL BRACE SPACED 8. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. p !48"O.C.ATTACHED TO VERTICAL WITH 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR if needed TYPE TRUSSES. `` BLOCKING WI1 6d TH(SD 10d NAILS.ATTACHED TO 10.10d AND 16d NAILS ARE 0.131"X3.0"AND 0.131"X3.5"COMMON WIRE NAILS RESPECTIVELY. 11.SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. E 2 DIAGONAL End Wail —HORIZONTAL BRACE Minimum Stud Without 2x4 DIAGONAL BRAGS AT" ` �\ (SEE SECTION A-A) I Stud Size Spacing Brace L-Brace BRACE 1/3 POINTS \IL Species + and Grade Maximum Stud Length i 2x4 SP No.3/Stud 12"O.C. 4-0-1 6-2-9 _8-0-1_ 12-0-2, 2x4 SP No.3/Stud 16"O.C. 3-7-10 5-4-9 7-3-5 -r-10-10-15 A 2x4 SP No.3/Stud 24"O.C. 3-0-3 4-4-11 6-0-6 9-0-9 2x4 SP No.2 ` 12"O.C. 4-2-9 6-2-9 8-2-5 12-7-12 2x4 SP No.2 16"O.C. 3-9-15 5-4-2 7-7-14 11-5-14 + 2x4 SP No.2 24"O_.C. 3-4-2 4-4-11_ 6-8-5 10-0-7 Diagonal braces over 6'-3"require a 2x4 T-Brace attached to—1 i one edge. Diagonal braces over 12'-6"require 2x4 I-braces attached to both edges. Fasten T and I braces to narrow edge € of diagonal brace with 1 Od nails 6in o.c.,with 3in minimum I I end distance. Brace must cover 90%of diagonal length. T or I braces must be 2x4 SPF No.2 or SP No.2. 1 MAX MEAN ROOF HEIGHT-30 FEET EXPOSURE B or C ASCE 7-10 170 MPH STUD DESIGN IS BASED ON GOMRONENTS'AND'l3LADDING] DURATION OF LOAD INCREASE:1.60 CONNECTION OF BRACING IS BASED ON MWFRS. 1 1 I i r ' k ' FEBRUARY 14, 2012 : Standard Gable End.Detail SHEET 2 Mirek USA,Inc. Page 2 of 2 1 i R. t ! !i• ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD j „ , „ I l ..._.........__........-_._......L....._...': Trusses @ 24" o.c. J i I i li I HORIZONTAL BRACE 2x6 DIAGONAL BRACE SPACED 48"O.C. SEE SECTION A-A) ATTACHED TO VERTICAL WITH(4)-16d Mirek USA,Inc. Roof Sheathing j COMMON WIRE NAILS AND ATTACHED j -- TO BLOCKING WITH(5)-10d COMMONS. t-:...:o-ten. ._".r:.;,•.n....:...._.t:,,:,,:::pu..._ { :1 Max. ..--.._.. .-...__.1 IT IS THE RESPONSIBILITY OF THE BLDG DESIGNER OR ! i! I t ! NAIL DIAGONAL BAACE'TO THE PROJECT ENGINEER/ARCHTECT TO DESIGN THE ! PURLIN WITH TWO 16d NAILS CEILING DIAPHRAGMAND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS t I I j 2X 4 PURLIN FASTENED TO FOUR TRUSSES WITH TWO 16d NAILS EACH.FASTEN PURLIN TO BLOCKING W/TWO 16d NAILS(MIN) ! Diag. Brace . I 1! PROVIDE 2x4 BLOCKING BETWEEN THE TRUSSES at 1/3 points I !;. y; SUPPORTING THE BRACE AND THE TWO TRUSSES if needed ON EITHER SIDE AS NOTED. TOENAIL BLOCKING j ~„�. %"• I TO TRUSSES WITH(2)-10d NAii ry T EACH END. ATTACH DIAGONAL BRACE TO BLOCkING WITr• (5)-10d COM:AON„V/I@E NAILS•••• •• • End Wall = f_._..,.. �• - CEIWMG IYGATHING • • i • _._._.---......_.—._..__..__-.__.__._....._..._....._......._..._._.__._._._.._....___-...•_._- .. ._.. BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES •• • • •••. ...................... ... ._. . STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: •' • •��i•♦ STRUCTURAL ••••+ METHOD 1 :ATTACH A MATCHING GABLE TRUSS TO THE INSIDE • ., •GAB9LETRUSS FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE ,0• •}•;_ •• !• 000000 FOLLOWING NAILING SCHEDULE. ”` •» METHOD 2:ATTACH 2X SCABS TO THE FACE OF EACH VERTICAL : :I �•'' • SCAB ALONG •;.- MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING 00.0 . •I I • t NAILING SCHEDULE.SCABS ARE TO BE OF THE SAME SIZE,GRADE VERTICAL . •� ' •••4,0'. , • ; AND SPECIES AS THE TRUSS VERTICALS • • • i ' ••• • NAILING SCHEDULE: FOR WIND SPEEDS 120 MPH(ASCE 7-98,02,05),150 MPH(ASCE 7-10)OR LESS,NAIL ALL ! ”;•;ri. i` MEMBERS WITH ONE ROW OF 10d(.131"X 3')NAILS SPACED 6"O.C. FOR WIND SPEEDS GREATER 120 MPH(ASCE 7-98,02,05),150 MPH(ASCE 7-10)NAIL ALL L ,� MEMBERS WITH TWO ROWS OF 10d(.131'X 3")NAILS SPACED 6"O.C.(2X 4 STUDS MINIMUM) I MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. j L`;�• j ALL BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR INLAYED STUD VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. STRUCTURAL i II+��ii AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST kJ BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM GABLE TRUSS. i I l''•. CHORD TO RESIST ALL OUT OF PLANE LOADS.THE BRACING SHOWN I IN THIS DETAIL IS FOR THE VERTICAUSTUDS ONLY. + t , V s ' 4 NOTE:THIS DETAIL IS TO BE USED ONLY FOR , STRUCTURAL GABLES WITH INLAYED ' T\ STUDS.TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. • i Y j +I r e t . ;.•.'•• STANDARD ; GABLE TRUSS • I I : i ,J 4 w March 4, 2013 I BEARING BLOCK DETAIL ST-BLCK1 REFER TO INDIVIDUAL TRUSS DESIGN Mi rek USA,Inc. Page 1 of 1 FOR PLATE SIZES AND LUMBER'GRAOES m � .oo IMPORTANT This detail to be used only with one ply trusses , — — with a D.O.L.ilumber increase of 1.15 or higher. MiTek USA,Inc. Trusses not fitting.these criteria should be- examined individually. 0-3-8 ACTUAL BEARING SIZE BOTTOM CHORD SIZE LUMBER ALLOWABLE BEARING BLOCK ALLOWABLE LOADS BEARING BLOCK&WOOD BEARING ALLOWABLE LOADS REACTION NAILING PATTERN GRADE (Ib) .* ALLOWABLE LOAD(Ib) TOTAL EQUIVALENT BEARING LENGTH — —— SP— 2966 975 3941 0-4-10 2x4 BOTTOM CHORD DF., 3281 892 '4173 0-4-7 2 ROWS @ 3"O.C. _ _ _--- --_ (8 TOTAL NAILS) HF 2126 _772 2898 0-4-12 SPF 2231 754 2985 0-4-11 " SP ' 2966 1462 4428 0-5-3 2x6 BOTTOM CHORD DF 3281 1338 4619 -- 0-4-14 _ 3 ROWS O.."•• HF 2126 1159 3285 0-5-6 •0 0(iaTiDTAL A"');. •svF :' 2231 1131 3362_ _0-5-4 -r----r w. -- — -- - —— -- - • • • • SP 2966 1950 4916 0-5-12 2x8 BOTTOM CHORD DF 3281 1784 ...5065 0-5-6 i••� S @ 3'Off. — ------ ------- - — -- --- ---------•—•---------- (i6�OTALNAI(.$).. HF —2126 1545 3671 0-6-0 •••••• • • • • 2231 1, 1508 3739 0-5-13 00 • • •••••• • • • __4r •••••• CASE2 • • 'y CAS=E1 • 4"MINIMUM: •t• ••----- ----- HEEL HEIGHT' BRG BLOCK TO BE SAME 12 BLOCK SIZE,GRADE,&SPECIES —__— AS EXISTING BOTTOM CHORD. 12•BLOCK APPLY TO ONE FACE OF TRUSS. NOTES:- 1' OTES:1.USE LOWER OF TOP PLATE OR TRUSS WOOD SPECIES. �. 23HE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.'. 3.NAILS DESIGNATED ARE 10d(A 31-DIAM.x 3") , FOR BEARINGS NOT NEARER THAN 3"TO THE END OF A MEMBER(CASE 2),THESE VALUES MAY BE MULTIPLIED BY A BEARING FACTOR OF 1.10 i LOADS BASED ON FOLLOWING Fc PERPENDICULAR VALUES: SP =565 psi DF =625 psi HF =405 psi SPF =425 psi NOTE:VALUES DO NOT INCLUDE MSR LUMBER WITH"E"VALUES GREATER THAN 1,900,000 PSI OR NON-DENSE GRADE LUMBER. March 4, 2013 I BEARING BLOCK DETAIL ST-BLCK2 I { MiTek USA,Inc. Page 1 of 1 �L��--I ® REFER TO INDIVIDUAL TRUSS DESIGN V —�J�� FOR PLATE SIZES AND LUMBER GRADES IMPORTANT This detail to be used only with one ply trusses with a D.O.L.lumber.increase of 1.15 or higher. MiTek USA,Inc. Trusses not fitting these criteria should be examined individually. 0-5-8 ACTUAL BEARING SIZE ALLOWABLE BEARING BLOCK&WOOD BEARING ALLOWABLE LOADS BOTTOM CHORD SIZE LUMBER BEARING BLOCK AND REACTION ALLOWABLE LOADS NAILING PATTERN GRADE (Ib) * ALLOWABLE LOAD(Ib) TOTAL EQUIVALENT BEARING LENGTH SP 4661 975 5636 0-6-10 2x4 BOTTOM CHORD 2 ROWS @ 3"O.C. DF 5156 _ 892 6048 0-6-7 (8 TOTAL NAILS) HF 3341 772 _ 4113 0-6-12 SPF 3506 754 4260 — 0-6-11 -- ' SP 4661 1462 6123 0-7-3 2x6 BOTTOM CHORD DF_ 5156 1338 6494 0-6-15-- 3 ROWS @ 3.O.C. HF 3341— 1159,. 4500 0-7-9.9e (12 TOTAL NAILS) • SPF _3506_ 1131_ _ 4637 _ . • 0-14... •_••••• ------ -- —— --SP 4661 1950 6611 ••� : 0 7 31 • __ • 2x8 BOTTOM CHORD DF 5156 1784 6940 •••••• 6-76•�: ••• • 4 ROWS @ 3"O.C. . — — -— ------ --�— -- --—---- (16 TOTAL NAILS) HF 3341 1545 4886 •••••• 0-8-0 • SPF 3506 1508 5014 *900 0-744•• • • • ' CASE1 CASE2 ' ' :•••:• 4"MINIMUM ------•---- 0 I • • •00 0 • • ••••w HEEL HEIGHT __— — — • :" r BAG BLOCK TO BE SAME 12'BLOCK SIZE,GRADE,&SPECIES AS EXISTING BOTTOM CHORD. 12"BLOCK APPLY TO ONE FACE OF TRUSS. NOTES: 1.USE LOWER OF TOP PLATE OR TRUSS WOOD SPECIES. 2.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH ; AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4 3.NAILS DESIGNATED ARE 10d(.131-DIAM.x 3") FOR BEARINGS NOT NEARER THAN 3"TO THE END OF A MEMBER(CASE 2),THESE VALUES MAY BE MULTIPLIED BY A BEARING FACTOR OF 1.03 LOADS BASED ON FOLLOWING Fc PERPENDICULAR VALUES: SP ' =565 psi - DF =625 psi HF =405 psi SPF =425 psi NOTE:VALUES DO NOT INCLUDE MSR LUMBER W.ITK"E"VALUES GREATER THAN 1,900,000 PSI OR NON-DENSE GkA-DE LUMBER. I: Permit No. 'RC-2-17-387 Miami Shores Villageova, Permit Type:Residential Construction 10050 N.E.2nd Avenue NE Pur Work Classification:AdditioniAlteration Miami Shores,FL 3313&0000 P8►Ti77it Status:APPROVED Phone: (305)795-2204 F�ORtDp' Issue Date:4!17/2017 Expiration: 10/14/2017 Project Address Parcel Number Applicant 672 NE 98 Street 1132060171780 Miami Shores, FL 33138- Block: Lot: CAROL INVEST USA INC Owner Information Address Phone Cell LCAROL I.NVEST USA INC 990 BISCAYNE Boulevard MIAMI FL 33132- 990 BISCAYNE Boulevard MIAMI FL 33132- Contractor(s) Phone Cell Phone JOSEPH S. ROBBIO INC (954)663-6743 Valuation: $ 50,000.00 Total Sq Feet: 430 Approved: In Review Available Inspections: Comments: Inspection Type: Date Approved: : In Review Final PE Certification Date Denied: Drywall Type of Construction:REMOVE EXISTING FLAT ROOF W Occupancy:Single Family Miscellaneous Stories: Exterior: Window Door Attachment Front Setback: Rear Setback: Tie Beam Left Setback: Right Setback: Final Bedrooms: Bathrooms: Framing Plans Submitted:Yes Certificate Status: Insulation Certificate Date: Additional Info: REMOVE EXISTING FLAT ROOF WI Fill Cells Columns Wire Lathe Bond Return: Classification:Residential Truss Insp Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Columns CCF $30.00 Foundation CO/CC Fee Invoice# RC-2-17-62944 Window and Door Buck $50.00 02/15/2017 Credit Card $50.00 $ 1,802.00 DBPR Fee $22.50 F.Termite Letter DCA Fee $22.50 04/17/2017 Credit Card $ 1,802.00 $0.00 F.Elevation Certificate Education Surcharge $10.00 Review Planning Permit Fee $1,500.00 Declaration of Use Plan Review Fee(Engineer) $120.00 Review Electrical Scanning Fee $57.00 Review Electrical Technology Fee $40.00 Review Electrical Total: $1,852.00 Review Planning Review Building Review Structural Review Mechanical Review Plumbing In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futh I authorize the above-named contractor to do the work stated. April 17, 2017 A=gDepartment ature:Owner / Applicant / Contractor / Agent Date Buil Copy April 17, 2017 1