RF-18-36 AC132 Engineering Inc.
Testing & Engineering Services
Certificate of Authorization#8131 Roof Tile Uplift Test Report
Tel: 954-245-8976 Fax:954-301-7776
5230 NE 18TH Avenue
Fort Lauderdale, FL 33334
Attention: Miami Shores Village, Building Division,
10050 NE 2nd Avenue, Miami Shores, FL 33138
Client: Evans Roofing
Test Date:05/24/2018 Permit# RF-1-18-36
Property Address: 372 NE 103rd Street, Miami Shores
Roof Pitch: Type of Tile: Roof Area:
3 in 12 Boral Roof Tile 20.00 squares
Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160
Field Instrument : IMADA Force Gauge 0-100 Serial number:243454
Test Location Total Number of Tests Field Uplift Pull Test Test results
Perimeter Area: (Ti-T8) 8.00 sq. 8 As per FBC 2017 Passed
Field Area: (T9-T20) 12.00 sq. 12 As per FBC 2017 Passed
No.of Corner (T21-T34) 14 14 As per FBC 2017 Passed
Ridge Areas: (T35-T52) 174 pcs. 18 As per FBC 2017 Passed
Important:
These laboratory results can change due to future weather impacts and/or unavoidable roof
traffic.Therefore,this report represents the TAS 106 results at the time of the test.
Please see attached a Roof Sketch for this project.
Cordially,
ACB2 En n ring Inc. (NOA 09-1005.01)
_ r
An ce do, PE
Fla. Re o: 6466
o ,1,2LI �
k
ACB2 Engineering Inc.
Engineering and Laboratory Services
5230 NE 18"Avenue
Fort Lauderdale,Florida 33334
Tel:954-245-8976 Fax:954-301-7776 {
L
70
�t
Tiv
by ,
) i
JZ
4