Loading...
RF-17-2882 (2) NReileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123' Avenue Miami,Florida 33175-1174 Tel:305-823-8008/305-397-6414 Fax:305-823-3300/305-884-8834 Website:www.reilehengineering.com March 1, 2018 John Busta Roofing 300 Northeast 91 Street Miami Shores; Florida 33138-3130 Project: ROOF TILE UPLIFT TEST REPORT Residential Home 351 Northeast 98 Street Miami Shores, Florida Information provided by ciient: Permit Number: Not Provided Date Completion: February 27, 2018 Roofing Contractor: John Rusta Roofing Project Number: 'Q-�`-' (Testing Laboratory Certificate #11-0715.04) Dear Sirs; In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof"file Uplift Tes+ at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding oft iiortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 200 square feet,and the mean height of the roof is less than 20 feet above ground surface. The type of tile used for this project was reported to be concrete/clay Roof Tile. This tile was reported it.) have been foamed in place. At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than one(1)tile in ten(10)of all components in the fiMd area and one(1)tile in five(5)of all tiles in the perimeter and comer areas were physically examined. A minimum of one(1)test per every two (2) squares in the field, one (1) test per square in the perimeter area, ridge caps and one (1) test in each corner were conducted. Based ori our test.results, we conclude that the installation of the roof tile at the above referenced project.meets the test requirement outlmecl in-the aabove-mentioned protocol. Attached please find a copy of our test repoft,for.your review. . . n. > Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. 4 , Respectfully submitted; Reileh Engineering Corporation ohamad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT TEST Residential Home 351 Northeast 98 Street Miami Shores,Florida Submittals: Cover Page Page 2 thru 3 of 3 Drawing 18-0252 i a 1 Reileh Engineering Corporation--Project Number- 18-0252—Page 2 of 3 I i F Report of TILE UPLIFT TEST for Residential Home 351 Northeast 98 Street Miami Shores, Florida Project Number: 18-0252 Test Number Test Load lb Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass Test 1-4 Perimeter Reileh Engineering Corporation--Project Number- 18-0252—Page 3 of 3 Nor'TH J I- 5' 1 2 3 9 NUMl3MM 0r TE5T 10O 5� - 0 KIOCZ CAP S5T LOCATION FEW - O COKNMK O 5M COM PMMMK O P�MIMMT>;M P15TANCM, a = 5' L MNMPFNOTM5 005 111 18-0252 MIPC4F CAP - O COUK AMA- 3'X 3' APMOX.WOF T5T f.00ATION5,AITA5, ANP PIWN51ON5