RF-17-2882 (2) NReileh Engineering Corp.
(Consulting Engineer)
2370 Southwest 123' Avenue
Miami,Florida 33175-1174
Tel:305-823-8008/305-397-6414
Fax:305-823-3300/305-884-8834
Website:www.reilehengineering.com
March 1, 2018
John Busta Roofing
300 Northeast 91 Street
Miami Shores; Florida 33138-3130
Project: ROOF TILE UPLIFT TEST REPORT
Residential Home
351 Northeast 98 Street
Miami Shores, Florida
Information provided by ciient:
Permit Number: Not Provided
Date Completion: February 27, 2018
Roofing Contractor: John Rusta Roofing
Project Number: 'Q-�`-'
(Testing Laboratory Certificate #11-0715.04)
Dear Sirs;
In accordance with your request and authorization, a representative of Reileh Engineering
Corporation completed the Roof"file Uplift Tes+ at the above referenced project. This testing was
performed in general accordance with Roofing Application Standard TAS No.106 -- Standard
procedure for field verification of the bonding oft iiortar or adhesive set tile system and mechanically
attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 200 square feet,and the mean height of the roof
is less than 20 feet above ground surface. The type of tile used for this project was reported to be
concrete/clay Roof Tile. This tile was reported it.) have been foamed in place.
At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than
one(1)tile in ten(10)of all components in the fiMd area and one(1)tile in five(5)of all tiles in the
perimeter and comer areas were physically examined. A minimum of one(1)test per every two (2)
squares in the field, one (1) test per square in the perimeter area, ridge caps and one (1) test in each
corner were conducted.
Based ori our test.results, we conclude that the installation of the roof tile at the above referenced
project.meets the test requirement outlmecl in-the aabove-mentioned protocol. Attached please find
a copy of our test repoft,for.your review.
. .
n. >
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you
have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
4 ,
Respectfully submitted;
Reileh Engineering Corporation
ohamad Sonny Salleh, P.E.49014
Project Manager
TILE UPLIFT TEST
Residential Home
351 Northeast 98 Street
Miami Shores,Florida
Submittals:
Cover Page
Page 2 thru 3 of 3
Drawing 18-0252
i
a
1
Reileh Engineering Corporation--Project Number- 18-0252—Page 2 of 3
I
i
F
Report of
TILE UPLIFT TEST
for
Residential Home
351 Northeast 98 Street
Miami Shores, Florida
Project Number: 18-0252
Test Number Test Load lb Test Status
1 35 Pass
2 35 Pass
3 35 Pass
4 35 Pass
Test 1-4 Perimeter
Reileh Engineering Corporation--Project Number- 18-0252—Page 3 of 3
Nor'TH J
I-
5' 1 2 3 9
NUMl3MM 0r TE5T 10O 5� - 0 KIOCZ CAP S5T LOCATION
FEW - O COKNMK O 5M
COM PMMMK O P�MIMMT>;M P15TANCM, a = 5' L
MNMPFNOTM5 005 111 18-0252
MIPC4F CAP - O COUK AMA- 3'X 3'
APMOX.WOF T5T f.00ATION5,AITA5, ANP PIWN51ON5