RF-18-975 S'
s
AC132 Engineering Inc.
Testing & Engineering Services
Certificate of Authorization #8131 Roof Tile Uplift Test Report
Tel: 954-245-8976 Fax:954-301-7776
5230 NE 18TH Avenue
Fort Lauderdale, FL 33334
Attention: Miami Shores Village, Building Division,
10050 NE 2nd Avenue, Miami Shores, FL 33138
Client: Prudentis Roofing
Test Date:05/03/2018 Permit# RF-4-18-$975
Property Address: 580 NE 92"d Street, Miami Shores
Roof Pitch: Type of Tile: Roof Area:
3 in 12 Concrete Roof Tile 45.76 squares
Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160
Field Instrument : IMADA Force Gauge 0-100 Serial number:243454
Test Location Total Number of Tests Field Uplift Pull Test Test results
Perimeter Area: (T1-T20) 20.00 sq. 20 As per FBC 2017 Passed
Field Area: (T21-T46) 25.76 sq. 26 As per FBC 2017 Passed
F
No.of Corner (T47-T61) 15 15 As per FBC 2017 Passed
Ridge Areas: (T62-T75) 136 pcs. 14 As per FBC 2017 Passed
Important:
These laboratory results can change due to future weather impacts and/or unavoidable roof
traffic.Therefore,this report represents the TAS 106 results at the time of the test.
Please see attached a Roof Sketch for this project.
Cordially,
A Engineering Inc. (NOA 09-1005.01)