Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-17-2711 (2)
GEOTECHNICAL 1 ENVIRONMENTAL 1 MATERIALS TESTING 1 ASBESTOS I ROOF TESTING 1 INSPECTION SERVICES I DRILLING SERVICES c DYNATECH ENGINEERING CORP, WWW.DYNATECHENGINEERING.COM CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH FLORIDA BUILDING CODE TEST POTOCOL TAS-106 t MIAMI,May 8,2018 PERMIT No.RF-11-17-2711 CLIENT: Jim Obenour: OBENOUR ROOFING: 9822 NE 2"d Avenue,#9,Miami Shores,FL 33138 PROPERTY ADDRESS: 277 NE 101ST STREET MIAMI SHORES,FL 33138 TILE TYPE/ATTACHMENT: Double Roll Roof Tile Polyfoam Set. Inspected By:DB } Testing Equipment:Humboldt Scale Model H-4620 The test results presented here reflect the condition of the roof system at the time of the test.These results are time and sample dependent since i roof condition are continuously changing due to the exposure to the element and rooftop traffic.Client recognizes that actual conditions in areas not tested by DEC may differ from those anticipated in DEC's report.Client understands and accepts that this can significantly increase the cost of construction for its future projects.Client agrees that DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC. Test No. Test Location Field Uplift Pull Test Test Result 1 -40 Field See Sketch Below >Than 35 LBS Passed 41 -47 Corner See Sketch Below >Than 35 LBS Passed 48-85 Perimeter See Sketch Below >Than 35 LBS Passed 86-96 Ridge caps See Sketch Below >Than 35 LBS Passed ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 ROOF SKETCH t z. r4' 47 48 _. -50 __ 51 ---- 52--_-_53: 41 7: . 7 -J 76' 36 37 38 39 40 '54 r--' 46 79 78 - ---- 75, 35 3432 :55 33 31 BO i ' 5 74 i 27 28 293089 9i 56 al i 6 7 8 4 73 9 10 .57 24' 14 13 12 11 i 3 y3 i 72 SB 16 17 18 19 f 4�84 85 24 ----------- ---- ' 71 20 _ 61 60 59 42 s 25 5 7-- `--- 62 F Q, 23 70� 22 63 � 26 21 10' I44 69 68 67 66 ~43 12- 14' 2'14• —� 30' ours, °°��$AAD �.° Wissa aamani,P.E. No.3.9584 1 1 , D ATECH ENGINEERING CORP. = r Florida Reg.No. 39584 '�'� STATE OF :� Special Inspector No. 757 ©° ��� to ss'®MAL 750 WEST 84TH STREET.HIALEAH,FL 33014 PHONE(305)828-7499 FAX(305)828-9598 EMAIL:INFOODYNATECHENGINEERING.COMEC 00/ Page 1 of] { 4 r • r ' AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-Bt1ILT r,.•�� SINGLE FAMILY RESIDENTIAL STRUCTURES 1 PURSUANT ,'O SECTION 553.844 F.S. ,/V1 i mF A PrP S v /W (vC R 33131 To: � � �� �� /nt2n„ flpffl } 3()5 _ j 0jS_,DoLj b 4 Re; Owner's Name PKI,It, Ev r i ryi5 Property Address _ 12q NC S f f 1 ua,16 il�p KS 4 Rooting Permit Number, Dear Building Official: certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water bafrier has been provided as required by the"'Manual of Hurricane Mitigation Retrofits for Existing,Site-Built Single Family Structures" adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. Qualifyin Age ' t 1 Signature of Qualifying Agent Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADS Swom to and subscribed before me this. /_q day of Ili n g. ,20_L§ (SEAL) HENRY ALBERTO 1R A•«'-' Notary Public-State of Florida' r; Commission=GG 182842 CCS Ily My Comm.Expires Feb 5,2022 _Or OdUCed Bonded through National Notary assn. E f 1 r • .i• r F t