Loading...
RC-18-484 f h PermitNO. RC-2-18-484 �s*!ORS of Miami Shores VillagePermit Type:Residential Construction 10050 N.E.2nd Avenue NW rte, Pen � ' Work Classification:Shed Miami Shores, FL 33138-0000 Permit Status:APPROVED Phone: (305)795-2204 FtoRioA Issue Date.3/20/2018 Expiration: 09116/2018 Project Address, Parcel Number Applicant 103 NW 97 Street 1131010260090 Miami Shores, FL 33150- Block: Lot: ISABEL QUIJADA Owner Information Address Phone Cell ISABEL QUIJADA 103 NW 97 ST MIAMI FL 33150-1734 Contractor(s) Phone Cell Phone Valuation: $ 2,140.00 HOME OWNER W m ....,,.,. .,.....__._ -. �- Total Sq Feet: 80 Approved:In Review Available inspections: Comments: Inspection Type: Date Approved::In Review Slab Date Denied: Final Type of Construction:ALUMINUM SHED Occupancy:Single Family Review Building Stories: Exterior: Review Structural Front Setback: Rear Setback: Review Planning Left Setback: Right Setback: Bedrooms: Bathrooms: t Plans Submitted: Certificate Status: Certificate Date: Additional Info: Bond Return: Classification:Residential Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $1.80 Invoice# RC-2-18-66575 DBPR Fee $2.00 03/20/2018 Cash $ 152.80 $50.00 \ DCA Fee $2.00 Education Surcharge $0.60 02/26/2018 Credit Card $50.00 $0.00 Notary Fee $5.00 Permit Fee $100.00 Plan Review Fee(Engineer) $80.00 Scanning Fee $9.00 Technology Fee $2.40 Total: $202.80 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futh re,I authorize the above-named contractor to do the work stated. March 20, 2018 Au orized Signature:Ownt) Applicant / Contractor / Agent Date Building Department Copy March 20, 2018 1 �U� �� R. Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores,FL t Phone. (30S)79&2204 Fos:(30 )x` 97'2 4 I NSP-303021 Permit um r: ':RC-2-18-484 Sc h-edutmd Inspection Date: June 21,2018 ---- Permit Type: Residential Con struction IttsPerA ; ; ? Inspection Type. i= tlal Owner QUI JADA,ISABEL Work Classifiica ` 'n:' )ted Job Address:103 NW 97 Street Miami Shores,FL 33150- Phone Number Parcel Number 1131 1€r260090 Project: <NONE> Contractor: HOME Building Department Comments ALUMINUM SHED tntractto Passed Gomrnente INSPECTOR COMMENTS wise d I 3 Inspector Comments PassedCREATED AS REINSPECTION FOR INSP-302836.CREATED AS REINSPECTION FOR INSP-298049. 5I1/201'8 LOCATION OF SHIED NOT AS PER PLANS Failed F7 Correction F-1Needed Re-inspection Fee No Additional Inspections can be scheduled until re-nspe0on fee Is paid .rune 20,2018 For Inspections please call:(305)762.4949 Page 17 of 37 R Miami Shores Village RRC rED / A Building Department Fdo 2s 218 f x 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 BY: INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 201�c`0' BUILDING Master Permit No. :T2 n G PERMIT APPLICATION sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS ,JOB ADDRESS: q-1 S City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type:,/� Flood Zone: BFE: j FFE: OWNER:Name(Fee Simple Titleholder): 1��Ibx' ,(DA I In j GI Phone#: I No SUS (-50 3 Address:_ID--� N 0 g 2 S t ,City: ml a 'Y) I 5h,0y/ /_State: 'P 1 zp: 3315 T .Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company.Name: Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ ,2 4 C) Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ff --❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ( L4 M/n U Y!'1 �/ e r Specify color of color thru tile: Submittal Fee 60 Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) d Bonding Company's Name(if applicable) L I;' � � Bonding Comdpany's A�"ddress ;City, ____ _ i State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City , State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS,HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the'recorded notice of commencement must be,posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature � d-� Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 23 day of 2U A 20 9 by day of 20 , by .4Z 0-PjlMNAR: I A 00�,who is personally known to who is personally known to me or who has produced 't'lL me or who has produced as idenJUL who did take an oath. identification and who did take an oath. NOTNOTARY PUBLIC: o0r°Psi Notary Public State of FloridaSign: r Sign: a156750 PrintPrint: x:C .L Seal: _ Seal: �►R Notary Public State of Florida d r ^ Sindia Alvarez *********************** Wo,,,.'X'd* ExPj11Si(A: tiQnFF156750 s0901. d.....° �7 APPROVED BY 4 Plans Examiner / Zoning Structural Review Clerk (Revised02/24/2014) 0 Miami Shores Village Building Department 10050 N.E.2nd Avenue RpiDP Miami Shores, Florida 33138 Tel:(305) 795.2204 Fax: (305) 756.8972 /OWNER BUILDER DISCLOSURE STATEMENT I NAME: 1,1 �f(s/�G� DATE: 2 /03 f , ADDRESS: ���j AJ W 9 75 lam i- by,,O �l 33 /_0 Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida,F.S 489.103(7).And I have read and understood the following disclosure statement,which entitles me to work as my own contractor;I further understand that I as the owner must appear in person to complete all applications. - } State Law requires construction to be done by a licensed contractor.You have applied for a permit under an exception to the law.The exemption allows you,as the owner of your property,to act as your own contractor even though you do not have a license.You must supervise the construction yourself.You may build or improve a one-family or two-family residence.You may also build or improve a commercial building at a cost of$25,000.00 or less(The new form states 75,000).The building must be for your own use and occupancy.It may not be built for sale or lease.If you sell or lease a building you have built yourself within one year after the construction is complete,the law will presume that you built for sale or lease,which is a violation of this exemption.You may not hire an unlicensed person as a contractor.It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances.Any person working on your building who is not licensed must work under your supervision and must be employed by you,which means that you must deduct F.I.C.A and with-holdings tax and provide workers'compensation for that employee,all as prescribed by law.Your construction must comply with,all applicable'laws,ordinances,buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner-builder permit under an F exemption from the law.The exemption specifies that I,as the owner of the property listed,may act as my own contractor with certain restrictions even though I do not have a license. Initial t. 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and i is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that,as an owner builder,I am the responsible party of record on a permit.I understand that 1 may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name.I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 1- L 4. 1 understand that I may build or improve a one family or.two-family residence or a farm outbuilding.I may also build or improve a commercial building if the costs do not exceed$75,000.ihe building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease.If_a building or residence that I have built or substantially.improved myself is sold or leased within 1 year after the construction is complete,the law will presume that I built or substantially improved it for sale or lease,which violates the exemption. Initial 5. 1 understand that,as the owner-builder,I must provide direct,onsite supervision of the construction.- Initial_ 6. '1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence.It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial L �. �f 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner-builder permit that erroneously implies that the property owner is providing his or her own labor and materials.I,as an owner-builder, may be held liable and subjected to serious-financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner-builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done.Any person working on my building who is not licensed must work under my direct supervision and must be employed by me,which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act(FICA)and must provide workers compensation for the employee.I understand that my failure to follow these may subject to serious financial risk. Initial .LIQ 9. 1 agree that,as the party legally and financially responsible for this proposed Construction activity,I will abide by all applicable laws and requirement that govern owner-builders as well as employers.I also understand that the Construction must comply with all applicable laws,ordinances,building codes, and zoning regulations. InitialT 10. 1 understand that 1 may obtain more information regarding my obligations as an employer from the Internal Revenue Service,the United States Small Business Administration,and the Florida Department of Revenues.I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.htmi Initial 11. I am aware of,and consent to;an owner-builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: I03 NIL.) G'1�- M �ai�'I �1 531's�) Initial_ 12. 1 agree to notify Miami Shores Village immediately of any additions,deletions,or changes to any of the information that I have provided on this disclosure. Initial--J Licensed contractors are regulated by laws designed to protect the public.If you contract with a person who does not have a license,the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court.It is also important for you to understand that,if an unlicensed contractor or employee of an individual or firm is injured while working on your property,you may be held liable for damages.If you obtain an owner-builder permit and wish to hire a licensed contractor,you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued,this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit.A copy of the property owner's driver license,the notarized signature of the property owner,or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this 23 day of � � , 20 1 By_ SA��— W � P ���w who was personally known to me or who has Produced there License or"fA- _NU kZX722- (_kI t-j Jt as identification. r..W, V,a...,;` Notary Public State of Florida 5Sindia Alvarez OWNER NOTARY ora. E p Expires Commission 8760 ? o� Ex ires09/03/2016 B o u n d a..ry Survey' a _.. -.�._. _ Page 1 of 2 Survey Number:•7447 r ' See Reverse Pro'pert'y Address :, s 103 N.W. 97th Street, ;f Miami Shores, Florida,33150 Certified T6: r• # ^� ���_M�_ - Isabel Quijada; ; ; , its' successors and/orassigns, as their interests may appear`: ' ;Frb'od Msuraii_Ke. Rate Map (FIRM) Information : 'Cominunity'Nwn!ber: *VCI'52 000*0 000-00 T,11 d Number:. 0093 ••.••. Suffix: J . . • • 0. Flood Zone: 1C *see*; Panel Revised Date: 03/02/94 01. Legal Descr�dligt arpvided by tlie'client.This survey does not determine or imply ownership. 2. Examination df tlleabstract of title will have to be made to determine recorded instruments, if any, affecting this property. 3. Unless a comparison is shown,all measured bearings, angles and distances shown along the boundary lines are same as platted values. 4. Elevations and vertical data, if shown are referred to N.G.V.D. 1929. 5. Underground utilities,footings, and/or underground encroachments are'not located on this survey map. 6. Fence"ownership not determined.Apparent fence clearances and/or encroachments are noted by visual means only. 7. No identifications caps found on recovered monuments, unless otherwise noted. 8.This survey is exclusively for the use of the parties to whom it is certified. I c 9.Additions or deletions to this survey map and/or report are prohibited. 10.This survey map is not valid without the signature and original raised seal of a Florida Registered Land Surveyor and Mapper. i Legal Description: Lot 9, Block 2, A RESUBDIVISION OF BLOCK 2 OF BONMAR PARK,according to the map thereof,•as recorded in Plat Book 42, Page 59,of the Public Records of Miami-Dade County, Florida.. t,. t1f`, , a l , i I hereby certify that this Sketch of Survey of the hereon described property is a true sand correct representation of a survey made under my direction and said survey meets the minimum technical standards as set forth by the FLORIDA BOARD OF PROFESSI6NAL SURVEYORS AND MAPPERS in Chapter 61G17-6 Florida Administrative Code pursuant to Section 472.027 Florida Statutes and is accurate and correct to the best of my knowledge and belief. Field Work Date: 3 r s 8, I Odalys C. Bello, P. S. M: n " r Professional Surveyor and Mapper No. 6169 - A 12230 S.W. 131st Avenue, Suite 201 Miami, Florida 33186 4 Tel: (305) 251-9606 Fax: (305) 251-6057 a s Boundary Survey Page�2 of 2 Survey Number: 7447 Scale: 1" = 20' See Reverse Thl's Survey Map is not valid without the signature and original raised seal of a Florida Registered Land Surveyor and Mapper. , Miami Shores Village APPROVED BY DATE ZONING DEI5T_ 7C N. 98th STREET 4BL�GEPT �� I U, I FAQ I TO COMPLIANCE'WITH ALL FE[S AL i *00 1`'lATFADCOUNTYRULE I • • •••••• I�> SAND REGULATIONS ••••� ',.• • � •• �J I 15' ALLEYsI ASPHALT PAVEMENT I ..,. i••••; / �' 81'.28' ;`••.•` •..` 9 FD. .... ( , xx-x -x x-x-x-x-x-x-x-xwwo- 1/r►J�•;••• ••;•• �� ••••• �I PP �GIT 07 < L- ••x•;• LU 0.40 ��� e�� I ••••• y r•:: / I• • • F •••••• ' ..... ; X. I•L. •• 21.35 � . . 10.45 .1 /': I I F- d of S CONT. . 1. I ASPHALT 'DRIVEVVAYF wi to �. �:...• I N rn N 10.00' ^ I / I W Z a 0 , N Lu � I N C'4 I 30.00' PL x-x i N Lq Q O O I $ 14.90 a ~ ONE STORY I- RESIDENCE 9 >arl a Z I 10n 0.40• BLOCK 2 FF-13.88' BLbLK 2 —x—x—x I I 20.4(r 14.94 48.07 PCPL 1/7 IR 3007 ° N eQ N N I FZ). c'e..'b �. Pr C 81.32' P. 81.30' M. IT PARKWAY = 90-13'16- R = 25.00' 89e �41. T = 25.1014e3e 28'ASPHALT PAVEMENT N.W. 97th STREET L = 39.37' M 75'TOTAL RNV l • � l SurveYOl s Nots: BENCH MPGfZK USED:N-494 ELEV:10.79' LEGEND&ABBREVIATIONS A.ARC OHBTANCE�H�•LENGGIH CONCRETE•.AK}AR CONDITIONER AE-ANCHOR EASEMENT ASPW AN%&T D8-D®BOOT( BLDG.BUILUM ELEV,ELEVATION CALCONCRETE MONUMENT CLF-CHAIN NKK FENCE OF.-DRAINAGE EASBAEW CH-CHORD BMP BENCH MAIN DALE-OIARLUX&MAINTENANCE EASEMENT ILC.-BLOCK OOR ER Dr DESCRIPTION OR DEW ECR-ENCROACHMENT SK O d a l ys BAING-BEAR1169BICO C.-CALCULATED FX-FOUND NAL FDMI FOU D DRLL HOLE FAP.FOUND RON PPE FUR-FOUND ETON ROD CR'CATCH BAFD.-FOLIO FPR-FOLIO PAR®GNALON IAL FFA.FLASHED FLOOR MH-MANHOLE PG.-PAGE R.RADRA ,'-N"""LANGLEM TA p`�`�BE"�"� �`G`L' " F-�L� N'L-NON�AL `BA-C°"�BOCK PROFESSIONAL SURVEYOR AND MAPPER A� WOCOiERM CATV-CABIELRYDY BOK W-FIEU)MEASRED MO/N•EM TIE ®0WEREDAREA RAD.-TACHE D OONC.BLOCKWMLTVP. Mia-MOTTO SCALE ONE-OVE•EADUI&DIES OAB'OFT7lCMLRECOIDBBOOK BDC'SECIION 12230 S.W. 131 St Avenue, Suite.201 —x—x—CHAIMUNLF'ENCE !-PROPFAIVLBE P.-PLAT PP.-POMIERPOLE PACM -PLATBOOK P. .POOFCURVATRE PAM,PROFE,SsIONALNIRVEYORANDMAPPERP.T.- POIGCOFTANGMCY P.C.C'POMROIN OFCOLPOICUE PAL.POKTGNLIE Miami, Florida 33186 PAC_.PONTOFEEVERSECURVE P.OR-POINT BEGN 49 P.=-POINTOF COMMENCEMENT P.0E P.- PERMANENT CONTROL POINT PAW REFERENCE MONUMENT REC.-RECORDED D•EIMICH RAM.RIGHT OF WAY SlA-BEI ROH ROD&CAP BWK-SIDEWALK TEL F" &NYS WAIL ': �RK ;°aW.F-�FENE HSE"T. Tel: (305)251-9606 Fax: (305)251-6057 EO.Wa EDMOFWATER ®WOODDE'CK VNABRALTPAVEMENT FLA Manufactured Building Program s 140 Norwroe SheetBusjnel Sutie90A Professha Ta"ahassee, Florida 32399-0772 Regulation Phone:850.487.1824, Fax:850.414.84M Ken Lawson,Secretary Rick Scott,Govemor September 23, 2016 Alex Martens Superior Sheds, Inc. 2323 S.Volusia Ave Orange City, FL 32763 RE: Manufacturer Certification, ID MFT-113; Expiration Date: September 22, 2019 •• • • •• • •Y • • Dear Alex Martens • e • � yecYe• • a• •eee•• Y It is my pleasure to inform you that Superior Sheds, Inc., located at 2323 S.Volusia Ave, Orange•• • • :.•..: City, FL 32763, has been approved under the Manufactured Buildings Program,,as provided for* •a• : e •• e under Chapter 553, Part I, Florida Statutes, to manufacture Storage Sheds, Manufactured •�'• • •• .e:••• ••• •••• •e••• Buildings for installation in Florida. •••• • � . • Y• •• Y• • •e••e• Construction or modification on a manufactured building cannot begin until the Third Party ,.•••• • •• Agency has approved the plans in accordance with the current Florida Building Code. Your Thir:j • : • • •••• • Party Agency is a contractor for the Department and has statutory authority and responsibilities • ••••• e • that must be met to maintain approved status.You may expect and demand quality plans • • ' •••••• review and inspections. • • • •e • i Each Code change will make your plans obsolete until they have been reviewed, approved and indicated [on the cover page of the plans]for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website.All site-related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. Your certification is approved for three years from this date.You will receive a renewal notice by Email generated by the BCIS(www.floridabuilding.org)for online renewal. If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.floridabuilding.orq to see valuable information on the Florida Manufactured Buildings Program.A copy of this letter must accompany applications for local building permits. r ; Sincerely, Robert Lorenzo Manufactured Buildings Program cc:Professional Service Industries i r+ Building Width Sus{G; "oat pan ' N b} (each a h and tae ►ir w ti D4 ALUMINUM ROOF SHEATHING Fasteners w/strap i Size Up to 14'Wide 1<k4" 4 u 1 I n »wr . (each end) -0" MAX. Max.Span NJ{b} 2-tx4-':j 9 {a; 0� 1 n�a jPRO! III 1 4x4' G-0' 0 3-3"x 0.131"nails a Tabu:atsd ra es ar,F N grade Spruce-Pin :r rlbsl. -j WILW-0- Iq 4 k4"w2 k4'` -- 8-0• ---- -- 1 6-3"x 0.131 nails b rJ,l�h I F .✓stuff Ia a i sJ to suaUcr,each e.:d. a.Tabulated values are for No.2 Made Spruce-Pine-Fir lumber. c d P t id .dok S Ld_ ..LI!_ F studs aid 9a b.NJ-Number ofjack studs required to support each end. c.Windew header for window openings that have more than 501.6 combined stud wall above and below,otherwise use door header schedule. 1.SEE FASTENER SCHEDULE FOR HARDWARE REQ(AREWII A d.See header details for alternate layouts,i.e.2-2'x4"or 4'x4"P.T. z SEE HEADER SCHEDULE FOR ADDITIONAL NFaMK i 3.WNDOW HEADERS HAVE COMBINED 5OX OR E WALL MWNG ABOVE e. The header can be attached to the top plate and thus haw the combined strength AND BEU*ODIERATSE REFER TO DOOR HEADERS. CODE INFORMATION equivalent and use the maximum span stated. i GOOF VERSION 2D61n EdIU-ASCII 2014 WC 1x4ix4 RUNNERS MANUFACTURER SUPERIOR SHEDS I t2 *'��� BUILDING TYPE MANUFACTURED EILp III` I RESIDENnA LAWN STORAGE - I0 1Y I 2-� CONSTRUCTION TYPE V-B SINGLE I _ - HEADER _ FIRE PROTECTION *so* NONE - FlRE SUPP ESSION•SYSTEM •••• NONE 000000 (2)2'x4-WITH 1/z-PLYWOOD • 2"x4" TRUSS OR OSB FLIER OR(1}1'x4- 1"x4- OCCUPANCY•• • •• • STORAGE • (^ 0 24" O.C. w MAX. I i `12'xf2'OR i6'x4-BETWEEN 4"•4' ALLOWABLP IRIMSER EDF STORIE; •• 1 • -J-y� WALL STUDS. " IS SECURED > V+-180MEATHIN1G ASNmal2" MAX. BASIC WIND ENEf • HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & EXPOSURE •.•• e c •••••• END WA rRuss DOOR 6' WIDE OR LESS 4r'x4" W 2'rx4" ENCLOSUR ••••• • • • ENCLOSED END W6 LL- LOPTIONAL� & DOORS TRUSS INTERNAL COEFFICIENT +/-0.18 • • IMPORTAN E AICTOR• • • • 1.15 V1tC'rtL'{G_& ROOF DEAD LOAD IOPSF • OUTLET + NOTES-OPTIONAL ELECTRIC y � ROOF IJVL•LOAr• • 3pPSF oft 3aoro••NT LOAD -ALL WIRING SHALL BE 14 CAGE 3-WIRE MC CABLE. C FLOOR DEAD LOAD •••••• IOPSF 000000 N IE -ENCASE IN ALL METAL BOXES. GQf�LM SOURCE 5 .-- •r<, >: FLOOR L� LoAp . STD.750§F- ,zSPlF DPT. DESIGN PRESSURES L 1 r 13r "R•RATING OF WAus. FLOORe 0%•• N/A • • / ROOF FRAMING PLAN WIRING DIAGRAM ACLS/DOORS/ INDO S +32.5/-29.2 MODULES PER BUILDING •• • 1 ROOF +27.8 -94.7 OPTIONAL) ans PlRevia Victor C.Martin,PE Ft PE K82379,W PE K42o1T HURRICANE PROTECTION USAGE F70 LSUCCC#U02436,TN PE 4120939 HURRICANE SHELTER USAGE NO WTEx OR ALPINE 2'x5• END*ALL -DOOR&WINDOW LOCATIONS VARY SQUARE FOOTAGE 719 SQ.FT.OR LESS OR EOUAL REVISIONS aa2 z-x4-COLLAR Wroc OR ALPINE z- " oETAL REV DESCRIPTON DATE B) OR EQUAL / THIFALUMINUM Ns z'MAX. / / ' A 2x4 STU SFE HEADER / / 3' 24'O.C. DETAIL 1x4 RUNNER ON NIDE1-1 /�/ // / �/ LiJ DM*rt By 2.4 EM WAS ; ,' MTB / Date: 12/12/17 g END WALL O Scale: � N/A 2.4 STUDS o 2.4 SOLE PLATE (n UJ .del 24.O.C.MAx. FLOOR FRAMING V) SS-B-18OCR1 LLJz.4 SOLE PLATE 2.4 SOLE PLATE ROOK FRAMINL 0-G 1.FOUN TpN PLANS ARE NOT PART OF THIS PLAN SET AND ARE 11 I"_ CCNERNED N LOCAL JUR15p�TpN 2 THIS BEADING 5 EQiAPT FROI,d THE FBC ENERGY CONSERVATION ALL STUDS SECURED 70 SOLE PLATE LV J CODE PER 101622. AND FLOOR FRAMING WITH(.039- a- 3.REFER TO TIE- DIAZ FOR PROPER INSTALLATION y (imm)xt2'STRAP W/6-10d NAILS STANDARD WALL DETAIL Will FRAMING MEMBERS ARE CONTINUOUS FROM Q F 7UF VENTS 10 EEr CODE 11 LJ LJ LJ OR EQUAL FQU 11ON SIU.TO ROOF AND SECURE ENSURE A � 4.ALL STUDS,RAFTERS,TRUSSES,ETC.ARE 2x4 12 SPF,ExCEPT /-FUDOR SHEATHING: WITH DOOR & WINDOW OPTIONS CoNITNUOUS LOAD PATH. WHERE WlAyLL M1D4BEs ARE F-- O AS NOTED. ARES W-O"TO IS ARIES 6'-0'TO 13•-0' -3/4'PLYWOOD NOT CONRNUlpOUU$$,,SHEET METAL CLVPS,TIES,OR CUPS (n (� 5.STRUCTURES OVER 400 SQ.FT.WILL HAVE AN 80'MINIMUM 3/4'P.T.PLYWOOD SHALL BE FORMED OF CALVA82ED STEEL OF NOT LESS DOOR ELEVATION CROSS-SECTION END ELEVATION 4-.t'P.T.ATTACHED WITH THAN 0.040•WMI44L THICKNESS, LLI 6.CUTTERS TO BE INSTALLED ON-SITE BY OTHERS THRU LOCAL H24 OR EouwALExT. sa -3/4'T&G TYPICAL ARCH FRAME WITH DOOR TARE 2 FOR gYNTIIY AND -3/4'P.T.T&G L LI 7.CODES. s AND DOORS 70 MEET THE MINIMUM SPECIFICATIONS SPMCIHG •-0'MAx. c AS PER FLORIDA BUILDING CODE &FLAT METAL STRAPS CAN BE DEW AROUND STRUCTURAL MEMBER OF ALL STUDS,TRUSSES,CHORDS,ETC.TO HELP SECURE THES TABLE 2 M KERS PROV DED TNAT THE ADOm BEND DOES NOT NTERFERI ____ ____ ____ ____ ____ ___ 1 • EXISTING BPAKES B DS THE STPAP. __-_ ____ ____ SHED WIDTH X1 X2 xa 111 111111// ' ,3•-8- r-lay r-LD1' r-1a�• Z n��S 10'-0- r-r s-1Y - ^_j \ .........., .(2)2'x4'LAID MT 8•-0' .'-9' 6'-e' - LL `\ '` -•y\�,t INS CI 51" - I rouAo ARE moo OP a mu ro ASHIFDs a fD 4•.r N � �'• � j -I _ I soar orae u•-e'MOE 9aaF mWC(4)3lIS o,,smS. LI J = � 2x4 BDCKNG ON p I n END AUS V 1 ext RDCNWO Q 2'x6'WD MT j IPJ I 2x6 P.T.24'O.C.TYP. / 1 I OPTIONAL 125PSF O 16'O.C. / -:• STATE •:�� TYP.WITH 3/4'T&C PLYBOARD 41x4'P.T.ATTACHED WITH I // <\••-', `O R 2x4 SOLE PLATEH24 OR WUNAI.ENT. SEE // ••.•-•• ••-.• C \\ FLOOR FRAMING •MAx. —- - H SPACE Z FOR aLIA)RT1TY AND O //''�V/O.......'`- ```\\ SPACING. '!A ' _ -- — — J ��//111 111111 LxJ LJ a IN Ij LJ ' I ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- (r'� Matthew T. Baldwin P.E. AWES 8•-0'TO 13•-0- ARCS 6•-0.10 13•-8- t___ ____ ____ V Florida License #64608 END ELEVATION END ELEVATION Z ,L.�.....� ....,.,, WITIJ rACI nnno FLOOR'XxsrSEE SCHEDULE FOR SIZE 77, • SETUP AND INSTALLATION OF SINGLE WIDE SHED CQJ SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR II. 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS 1 MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 1L PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2' ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)1"x44" ' SPACING (SEE TABLE 3). BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE - fi LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED 30" AUGER ANCHOR PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. CODE INFORMATION THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL (4,900LB) 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 48). on,CODE VERSION FBC 2017 5th EditiASCE-7 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS MANUFACTURER SUPERIOR SHEDS 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO REMOVED. BUILDING TYPEUFACTURED SUIUDING FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO RESIDENTIAL LAWN STORAGE CONSTRUCTION TYPE V-B 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. FIRE CONSTRUCTION PROTECTION_ _ • V-8 -- BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE - _ CONCRETE 1=1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM FIRE SUPPRESSIO1 SYSIEN 0 6641017 000• PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" OCCUPANCY •• • •• STQ�E • WEDGE ANCHOR. ALLOWABLE NUMBTR+•FOSFWIES • ,1, • 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS BASIC WIND SPEW e;0, V.-200.ph 2"x4" BOTTOM PLATE. EXPOSURE •• D •••••• 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE ENCLOSURE • • • ENgOSED • AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE INTERNAL PRESSURE COEFFICIENT +/-0.1e ••••• TABLE 1 TABLE 2 TABLE 3AHOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. IMPORTANCE FACTOR* • • •11� 00.00 ANCHORING TO CONCRETE SKID RUNNER SPACING* PAD TYPES 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). ROOF DEAD LOAD • 1adSF 000000 LOCATE ANCHORS PER TABLE 4A OR 4B. SHED WIDTH UPLIFT (PLF) ANCHOR SPACING SHED WIDTH X1 X2 X3 TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE ROOF LIVE LOAD• • •20PSF OR 3001es • 20'-0" 400 3'-6" 13'-8" V-104" 1'-10}" 1'-10}" I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. FLOOR DEAD LO • • fPSF ,00000 CEMENT AND SAND MIX FLOOR LIVE LOAt • STD.75PSF-1125PSF OPT, 13'-8" 280 3'-6" 11'-8" 2'-8" 6'-4" - II 4"x8"06" 3500LBS CONCRETE BLOCK QUALITY TABLE 4A0000 CEMENT AND SAND MIX 30" AUGER ANCHOR SPACING - SINGLE WIDE RATING OF FLdbR. ROOF •• 4/A , 11'-8" 240 3'-6" 10'-0" V-7" 6'-10" - III 16"x16" 3950LBS ABS PLASTIC PADS MODULES PER BUILDING •• j SHED WIDTH LW UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** HURRICANE PROTECTION USAGE NO 10'-0" 200 3'-6" 8'-0" 0'-9" 6'-6" - IV 8"x8%16" 1900LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX 13'-8" 7.00 243 0'-0"TO 3'-0" 10'-0" HURRICANE SHELTER USAGE NO 8'-0" 160 3'-6" 6'-0" 0'-10" 51" - • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) SQUARE FOOTAGE LESS THAN 720 SO.Fr. NOTES 11'-8" 6.00 208 0'-0"To 3'-0" 10'-0" 6'-0" 120 3'-6" *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" 1. HOLLOW OR SOUD CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED REVISIONS SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 1 O'-O" 5.00 174 0'-0"To 3'-0" 10'-0" REV DESCRIPTON DATE BY 2. ABS PADS REQUIRED ON 11'-B"AND 13'-B" WIDE SHEDS ONLY. 1 2017 FBC 9/15/17 MTB 8'-0" 4.00 138 0'-0"TO 3'-0" 10'-0" TABLE 3 6'-0" 3.00 104 0'-0"TO 3'-0" 10'-0" SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH TYPE LW-(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER INTERIOR SIDE RUNNER SHED WIDTH LW* UPLIFT PLF END ANCHOR** MAX. INTERIOR SPACING*** PAD TYPE PAD PAD TYPE (PLF) Drawn By: 13'-8" SW/DW 4.15/332 0"TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 20'-0" 10.00 400 0'-0"TO 3'-0" 5'-0" �C) MTB Date: 11'-8" SW/DW 6.00/480 0"TO 6" 6'-0" 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV * LOAD WIDTH OF UPLIFT ON RUNNER W4/26/16 *• LOCATION FROM END WALL OF AUGER ANCHOR = Scale: 10'-0" SW/DW 5.00/400 0"TO 6" 6'-0" 2400LB I, ll, III, OR IV 2400LB I, ll, III, OR IV ••• MAXIMUM SPACING BETWEEN ANCHORS N/A NOTES odel 8'-0" SW 4.00/320 0"TO 6" 6'-0" 2029L6 I, II, III, OR IV 2133LB I, II, III, OR IV 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. W ALL 2. ALL MEASUREMENTS ARE CENTER-TO-CENTER. C) GENERAL NOTES 6'-0" SW 3.00/240 0"TO 6" 6'-0" 1658LB I, ll, III, OR IV 1866LB I, ll, III, OR IV 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. 1. FOUNDATION PLANS ARE NOT PART OF THIS • LOAD WIDTH OF UPLIFT ON RUNNER ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" PLAN SET AND ARE GOVERNED BY LOCAL BETWEEN ANCHORS.. JURISDICTION. NOTES 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN 2. THIS BUILDING IS EXEMPT FROM THE FBC 1. PAD SPACING IS END TO CENTER OF PAD. EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE W ENERGY CONSERVAT!ON CODE PER SECTION 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. TO THE SIDE AS POSSIBLE. J 1015.22. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. m 3. REFER TO TIE-DOWN DETAILS FOR PROPER �D INSTALLATION REQUIREMENTS TO MEET CODE. 0 LLJ 2"x2" GALVANIZED WASHER J 2"x2" GALVANIZED WASHER WITH 1/2" NUT 1/2" THREADED ROD 0 WITH 1/2" NUT OPTIONAL FOR "HIGH SET" NOTCH OR COUNTERSINK BOLT - 1/2" THREADED ROD THRU 2"x4" BOTTOM PLATE _ EYES BOLTED TOGETHER WITH 1/2"x2" _ - U) OPTIONAL FOR "HIGH SET" BOLT & NUT WITH (2)2"x2" GALVANIZED 1/2" COUPLER 2%4" BOTTOM PLATE NAILED 1/2" COUPLER _ ( ) _ TO 2"x6" P.T. BASE WASHERS 2.000LB SHEAR CAPACITY : : /2"x12" FORGED EYEBOLT ;< 1/2"x5" (400 LB.) CONINTO RETESLB LLJ 1 4" MIN. WEDGE ANCHOR INTO SLAB _------- L __ _ 4" MIN. 0 " ., THRU 2"x4" P.T. BOTTOM PLATEA. - _------- - 'I (SEE TABLE 1 FOR SPACING) L------ EYES BOLTED TOGETHER WITH 1/2"x2" Ill 0 BOLT & NUT WITH (2)2"x2" GALVANIZED _ TYPE I, II, III, OR IV PAD WITH 1/2"x3" (400 LB.) SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH BLOCKING AS REQUIRED (SEE TABLE 3). WASHERS (2.000L6 SHEAR CAPACITY) � CONCRETE WEDGE ANCHOR CLIP OR EQUAL LOCAL CODES AND JURISDICTION LOCAL CODES AND JURISDICTION 30" EARTH AUGER ANCHOR (SEE TABLE 1 FOR SPACING) O (SEE TABLE 4 FOR SPACING) I SHED WITH SKID SHED WITH 'NO FLOOR' OPTION SHED WITH SKID -ANCHORED TO CONCRETE` ANCHORED TO CONCRETE - - Q TO PAD OR BLOCKING _ _ _ - - o J Matthew T. Baldwin P.E. TIE-DOWN DETAILS Q Florida License #64608 Z Sheet- AD- 1 OF 1