Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-18-1124
1 Permit O. MC4-18-1124 ' Miami Shores Village Permit Type.Mechanical-Residential 10050 N.E.2nd Avenue NErMot P e, Work Classification:A/C Replacement Miami Shores,FL 33138-0000 I Phone: (305)795-2204 Permit Status:APPROVER F�ORLDA r Issue Hate:611512018 Expiration: 11/11/2018 ' Project Address Parcel Number Applicant 1291 NE 96 Street 1132060143760 Miami Shores, FL 33138-2574 Block: Lot: MICHEAL A PALUCH&W&KAR 1 Owner Information Address Phone Cell MICHEAL A PALUCH&W&KAREN 1291 NE 96 Street - --- MIAMI SHORES FL 33138-2574 1 Contractors) Phone Cell Phone $ 6,617.00 Valuation: ARS/RESCUE ROOTER (305)235-7223 Total Sq Feet: 0 Tons:3.5 Available Inspections: Additional Info:A/C 3.5 TON 14 SEER 7 KW Inspection Type: Classification:Residential Final Approved: In Review Review Mechanical Comments: I Date Approved::In Review Date Denied: Type of Work: Scanning:3 I Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $4.20 Invoice# MC-4-18-67334 DBPR Fee $3.47 04/27/2018 Check#:82530125 $50.00 $207.59 DCA Fee $2.32 Education Surcharge $1.40 05/15/2018 Check#:8253012£ $207.59 $0.00 i Permit Fee $231.60 Scanning Fee $9.00 Technology Fee $5.60 Total: $257.59 I In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDA IT� rtify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction ng: F I uthorize the above-nam' contr for to do thpowork stated. _> �(/I�SC1J`1� ) May 15, 2018 Authorize ig nature:Owner / Applicant / Contractor / Agent Date Building Department Copy May 15, 2018 1 " Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Z Phone: (305)795-2204 Fax: (305)756-8972 , Inspection Number: INSP-304785 PermitNumber: MC-4-18-1124 Scheduled Inspection Date: May 24,2018 Permit Type: Mechanical - Residential Inspector: Perez,JanPierre Inspection Type: Final Owner: KAREN LANGHAUSER, MICHEAL Work Classification: A/C Replacement on1 i1ru Job Address: 1291 NE 96 Street ' Miami Shores, FL 33138-2574 Phone Number 1 Parcel Number 1132060143760 Project: <NONE> Contractor: ARS/RESCUE ROOTER Phone: (305)235-7223 Building Department Comments A/C 3.5 TON 14 SEER 7 KW Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed ® CREATED AS REINSPECTION FOR INSP-302802. 5/22/2018 TULIO 10:01 Failed i Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. May 23,2018 For Inspections please call: (305)762-4949 'Page 17 of 26 Miami Shores VillageRECFTVIED M Building Department ZP, 2o�s 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 1 Tel:(305)795-2204 Fax:(305)756-8972 B INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 261 BUILDING Master Permit No. AA c-- (p - 112- PERMIT 12-PERMIT APPLICATION , Sub Permit No. r ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING dMECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑SHOP Pr CONTRACTOR DRAWINGS JOB ADDRESS:• 12'91 N U 96 s-r 33� 3 s City: Miami Shores County: Miami Dade Zip: � Folio/Parcel#: 1t-3ZDl."0l N -37460 Is the Building Historically Designated:Yes !NO Occupancy Type: Load:, Construction Type: Flood Zone: BFE: I FFE: r •. F 4 a '1 OWNER:Name(Fee Simple Titleholder): M<<Re,,k ?P I",.yCA, Phone#:3aS 2 8i 636 (�!� �6st Address: � + City: M r DNS I State: . I Zip: Tenant/Lessee Name: Phone#: Email: , 'CONTRACTOR:Company Name: 4s ��r � � Phone#: -305- 205 _72-23 Address: City: PM! State:. _ Zip: 33 s 1 Qualifier Name: ^1Mca4<_ Phone#: .305 2,3572L3 f State Certification or RegistratiCKG !Z V-7 5-3 Certificate of Competency#:' ) r;'!icy+n:�,::. ..,:_;.;.:..�:w.a,..:.a ....; .•.._: _ � DESIGNER:Architect/Engineer: Phone#: Address'� City: State: Zip: eoPermit': = .. t Valuf Work for this Permit:$ ( 4 Square/linear Footage of work: , I Type of Work: ❑ Addition ❑ Alteration �, � ❑ NeW �'� _ Repair/Replace ❑ Demolition Description of Work:ALL 1-5 TDA /,q SGC Vi W Specify color'ofcolor thk tile: ._ Submittal Fee$ �- ' Permit Fee.$fe nCO/CC$:�•. Scanning Fee$ tR.,-M: , '--e-w -Radon Fee`$y" Y r DBPR$ r Notary$ j Technology Fee$ Training/Education Fee$° Double Fee$ I Structural Reviews$ Bond$ + TOTAL FEE NOW DUE$07 (Revised02/24/2014) + I { . 1 4 t on Ing Company's Name(if applicable) f Bonding Corp pany's'Address 4 .. City' State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and'that all work will be performed to meet the standards of all laws regulating 4 construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, } FURNACES,BOILERS, HEATERS,TANKS,AIR CONDITIONERS,ETC..... t - r OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO-OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY `RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY-. -IFYOUINTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF-COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a.building permit with an estimated value ezceedidg$2500, the`applicant must promise in good faith;that a copy of the notice'of commencement and constructions lien law brochure will be delivered to,the person whose property i`s'subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted'at the job site for the first inspection which occurs seven (7) days after the building permit is'issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature ' A OWNER or AGENT C TRA OR r Thforegoing'instru ent was acknowledged before a this 'The foregoing instrument was acknowledged before ine this day of 1 20 .by .day of 1A(A_clj/1' 20 by C L C- 1� Vhho is personally known to" C "_ o is personally known to + me or who has produced G�1 U��� Cir LQ :kme or who has produced as identification and who did take an oath. i en ification and who did take an oath. NOTARY P IC: o 111 RY PUBLIC: .g Q y o Sign. Ezo Print' V �'.0 k P�'�Np' K(, 0 33-,> Z _ = Q Seal' ' - KAR AMARG-� TH:D Ca 8° ,'_ Not a'y°:.bili ..�..Of ngdpg :•^aa'+�p&' AM ET HIDALGO z v �o o KARIN ARGAR Comm ss,on;GG 95176 a r: '_. `: Notary Public-State of Florida o My Comm.Expires Apr 19,2 0 40 Commission k GG 96176 N= '••.,opRw,o Bond t r '-r *r.'N `m'' v= O BordedthrcughNatioralNctaryAssn, APPROVED BY Plans Examiner ' Zoning A Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami-Dade County Page 1 of 2 OFFICE OF THE PROPER IY APPRAISER t7:S� Summary Report Generated On : 12/19/ Property Information I Folio: 11-3206-014-3760 A. I Property Address: 1291 NE 96 ST Miami Shores, FL 33138-2574 Owner MICHEAL A PALUCH&W KARENLANGHAUSER Mailing Address 1291 NE 96 ST MIAMI, FL 33138-2574 PA Primary Zone 1400 SGL FAMILY-3001-3250 SQ Primary Land Use 0101 RESIDENTIAL-SINGLE FAMILY: 1 UNIT Beds/Baths/Half6/4/0 E Floors 2 j Living Units 1 Actual Area Sq.Ft � Living Area Sq.Ft Adjusted Area 3,924 Sq.Ft Taxable Value Information Lot Size 15,416 Sq.Ft 2017 2016 2 Year Built 1929 County Exemption Value $50,000 $50,000 $50 Assessment Information Taxable Value $732,584 $716,488 $711, Year 2017 2016 2015 School Board Land Value $554,775 $569,962 $469,906 Exemption Value $25,000 $25,000 $25 Building Value $343,637 $343,767 $343,896 Taxable Value $757,584 $741,488 $736, XF Value $24,719 $24,928 $18,425 City Market Value $923,131 $938,657 $832,227 Exemption Value $50,000 $50,000 $50, Assessed Value $782,584 $766,488 $761,160 Taxable Value $732,584 $716,488 $711, Regional Benefits Information Exemption Value $50,000 $50,000 $50.. Benefit Type 2017 2016 2015 Taxable Value $732,584 $716,488 $711, Save Our Homes Assessment Cap Reduction $140,547 $172,169 $71,067 Sales Information Homestead Exemption $25,000 $25,000 $25,000 Previous OR Book- Second Sale Price Page Qualification Description Exemption $25,000 $25,00 $$25,000 Homestead 18308- 10/01/1998 $570,000 0492 Sales which are qualified Note: Not all benefits are applicable to all Taxable Values(i.e. County, School Board, City, Regional). 16821- 06/01/1995 $410,000 Sales which are qualified 3234 Short Legal Description 12012- 12/01/1983 $320,000 6452 Other disqualified MIAMI SHORES SEC 3 PB 10-37 LOT 2 BLK 83 00000- Sales which are disqualified as a res LOT SIZE 77.080 X 200 03/01/1977 $1 00000 of examination of the deed OR 18308-0492 1098 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appra http://www.miamidade.gov/propertysearcW 12/19/2017 Property Search Application - Miami-Dade County Page 2 of 2 Version: ? http://www.miamidade.gov/propertysearch/ 12/19/2017 - � (305) 235-7213 Corporate Customer � /td DISPATCH =, Jr 18720 S.W.108TH AVENUE Relations g� ���V TIME WINDOW `y ghtt- MIAMI;FL-33157- (866) 803-08`79- ���/,,.,, INVOICE: Making it work.�Maklrlg American Residential Services of Florida, Inc. License#CMC1249753 �� ��A�RS.com ARRIVAL 8253--086604 AIR-HEATING-AIR QUALITY NAME _DD r1 AAT0 CB t�ATG d r ADD _41PH# BILL ADD ,— . ❑TO UAW CALL#/Qt -V Y45 C/ST/ZR r �3 MAIL C/ST/ZP Ct, ❑OT . TEC . DIAGNOSIS RECOMMENDATIONSINVOICE ®• y . . .• •� • • • • • •� • A.B. C. SUCTION PSI SUPERHEAT LIQUID PRESS SUB-C COMP AMPS ODB OWB I J IWB IDB FAN AMPS GAS PRESSURE ELECTRIC HEATAMPS TEMP RISE RECOVERED REFRIGERANT LBS/ LBS DAMAGE? ❑ NO ❑ YES-See separate"Report".Tech initials_ ' ` • �' ORIGINAL SERVICE REQUEST IDALGO NotaryPubli� State fFlorida -�+ MY Comm.Expi es Ap 19,2021 r 2 y ffl. - .. fA 45 pill See Recommendations Addendum Option • Written customer authorization will be obtained SUBTOTAL before beginning any unforeseen additional or extended work. WARRANTY ITEM(S) • BUYER'S RIGHT TO CANCEL ;'This is a home solicitation ( � PARTS: LABOR:/ DIAGNOSTIC sale, and if you do not want the goods or services, you ORIG.EST FEE ma cancel this agreement b providing written notice to +SALES TAX Y 9 Y P 9 PARTS: LABOR: SUBTOTAL the seller in person, by telegram, or by mail.This notice Est.Start date - • must indicate that you do not want the goods or services Est`date of comp ❑ RENEW HSP. and must be delivered or postmarked,before midnight of p ❑ CASH ❑ CHECK# PO# ❑ PURCHASE the°third business day after you sign this agreement. If you cancel this agreement, the ❑ VISA ❑ M/C DISC ❑ AMEX ❑ OTHER TRUCK OPERATING seller-may not keep all of part of any cash down payment."See the reverse side hereof for SUPPLIES $9.95 an explanation of this right. CC LAST 4# q��L EXP AUTH# COMM TAX • I acknowledge that my right to cancel has been explained to me orally and in writing,and without waiving my right to cancel,I authorize the performance of the work,subject to all My signature below acknowledges that the work has been completed terms and conditions set forth on the reverse side hereof,plus any taxes upon completion. and I agree to the sum total of the charges and payment method. Total Sale Price • NOTICE TO OWNER - Do not sign this home improvement contract in blank. Print Name You are entitled to a copy of the contract at the time you sign.Keep it to protect your legal Please contact me about rights.This home improvement contract may contain a mortgage or otherwise create a lien Signature Date future offers. on your property that could be foreclosed on if you do not pay.Be sure you understand all provisions of the contract before you sign. ©2017. American Residential Services LLC.All rights reserved:(L 02/2017)Rev 100417 ARS1001 Signature:X Date: k M Gk + Miami Shores Village APPROVED BY DATE PR 2 2018 SNOC 193RES LZONING DEPT, Building Department MINI" BLDG DEPT 10050 N.E.2nd Avenue ° Miami Shores, Florida 33138 # t 1f3,11=CT TO COMPLIANCE WITH ALL FEDERAL Tel: (305)795.2204 S 1 A I I AND COUNTY RULES AND RFGIJI_ATIONS FaX:(305)756.8972 -� AIR CONDITIONING REPLACEMENT DATA AL I � PERMIT NUMBER: MC i orm must accompany ALL air conditioning replacement permit applications. Each unit change-out must be on its own data sheet. Multiple units on single sheets are not acceptable. c- Job Address(where the work is being done): �� q f N 96-A F City: Miami Shores Village County: Miami Dade• Zip Code: i ALL CONDENSING UNITS MUST BE ON A 4 INCKSOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION d A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED . a Change disconnecting means:YES El NO❑ .ARHI Sheet Attached:YES []""NO❑ Contract Attached:YES ❑ ' UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER ' - r `Z 1 f)q 2 S'TA 0 AHU or PKG.UNIT MODEL# H( Pq 2glJIN/A COND.UNIT MODEL# KW HEAT NOM TONS' ' I AHU f5 CU PKG 1) M.C.A AHU IS CU VPKG.. AHU jo CU ' PKG 2) M.O.P AHU la CU PKG, 1 AHU CU PKG 3)VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / /E EER/SEER / YES ,N41/, REPLACING DUCTS_ YES YES 0 REPLACING THERMOSTAT YES - YES O NEW 4-CONCRETE SLAB YES 0 I' YES NO NEW ROOF STAND• YES YES (N: NEW RETURN PLENUM BOX YES O 1. Minimum Circuit Ampacity(Wire Size): f 2. Maximum Overcurrent Protection (Fuse/Breaker Size):' r � { 3. Voltage of Circuit(208/240/480): (A 1' 4. Size Disconnecting Means: 2 ,} Contractor's Company Name: Q l Ir Pho C D,J J 1 a � 3 State Certificate or Registration NoCU�•LL V`1�1�5 Certificate of Competency No. , Signature Date: 1,to �ak t -t) w (Q ier's sig lure) , t (Revised02/24/2014) 1 1 -771 MWILI CERTIFIED' Certificate of Product Ratings � AHRI Certified Reference Nu ber :201435276 Date:02-22-2018 Model Sta us :Active t I Old AHRI Reference Number :8954589 AHRI Type :RCU-A-CB Series i Outdoor Unit Brand Name :RHEEM a Outdoor Unit Model Number (Condenser or Single Package) :RA1442BJ1 Indoor Unit Brand Name Indoor Unit Model Number(Evaporator and/or Air Handler) :RH1P4221STAN Furnace Model Number : Region :Southeast and North(AL,AR,DC,DE,FL,GA,HI,KY,LA,MD,MS,NC,OK,SC,TN,TX,VA,AK,CO,CT,ID,IL,IA, IN,KS,MA,ME, 1 'MI,MN,MO,MT,ND,NE,NH,NJ,NY,OH,OR,PA,RI,SD,UT,VT,WA,WV,WI,WY,U.S.Territories) Region Note :Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in,all regions until June 30,2016. Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency t requirement - — - x• _ _ . r__ The manufacturer of this RHEEM product Is responsible for the rating of this system combination. Rated as follows iri accordance with the la' st edition of SI AHRI 210/240 with Addenda 1 and 2,Performance Rating of Unitary Air-conditioning &Air-Source Heat:Pu"mp Egtiipment and subject to lratingaccdracy by AHRI-sponsored,,independent,third party t artyi esting:g; - ' - I� ( t •�` ° , ` iM1 � , Cooling Ca actY( 2)- tuhSin le or Hi h Sta "95F 40000 (1,i SEER,: 14.00 EER(A2)-Single or High Stage(95F) : 12.20 tl�u`C;r,^s lq P rr r , 1 ��1. r 2'4yks j # IEER k I t 1 I t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re rate The new published rating is shown along with the Drevious(i.e.WAS)rating DISCLAIMER 4 AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate:AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS i This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE r The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, j which is listed above,and the Certificate No.,which is listed at bottom right. ------ li( 131638034820454583 ©2018Air-Conditioning,Heating,and Refrigeration Institute FC ERTIFICATE NO.: [ �rr Air 1Electrical Data 1 RHiP Series [ Electrical Data - Blower Motor Only- No Electric Heat Model Voltage Hertz HP[W] RPM Speeds Application Circuit Minimum Maximum RH1P phase' Amps Circuit Circuit Ampacity Protector 1817ST 1/5[1491 1075 2 2.3 3.0 15 2417ST 1/5[149] 1075 2 3.8 5.0 15 3017ST 1/4[186] 1075 2 4.7 6.0 15 3617ST 115 1 1/3[249] 1075 2 6.1 8.0 15 4221ST 1/2[373] 1075 2 7.9 10.0 15 4821 ST 3/4[559] 1075 2 8.4 11.0 15 1817ST 1/5[149] 1075 2 1.7 3.0 15 2417ST 1/5[149] 1075 2 1.7 3.0 15 3017ST 1/4[186] 1075 2 2.5 4.0 15 208/240 1&3. 60 ` 3617ST/3621ST 1/3[249] 1075 2 2.5 4.0 15 T! 4221ST; 1/2[3731 1075 2 5.2 7.0 15 4821 ST/4824ST 3/4[559] 1075 2 5.2 7.0 15 6024ST 208/240 3 60 3/4[559] 1075 2 5.2 7.0 15 #i 3617ST 1/3[249] 1075 2 1.4 2.0 15 4221ST 480 3 60 1/3[249] 1075 2 2.1 1 3.0 1 15 [ l 4821ST/4824ST 3/4[559] 1075 2 2.2 3.0 15 6024ST 480 3 60 3/4[559] 1075 2 2.2 3.0 15 *Blower motors are all single phase motors. r [ ]Designates Metric Conversions E 12 INTEGRATED r 1 rl j - r e 1 , 1 r i . . .- Air Electrical Data 0 RH1PSeries Electrical Data -With Electric Heat Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements r Air Handler Heater kW No.Elements Type Supply Circuit Motor Minimum Maximum Model RH1P Heater Model No. (2� V) PH/HZ kW Per. Circuit MulCircuit tiple Amps. Ampacity Am 4 OV) pac ty Protection RXBH-1724?03J 2.25/3.0 1/60 1 -3.0 SINGLE 10.8/12.5 1.7 16/18 20/20 RXBH-1724?05J. 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20.0 1.7 24/28 25/30 RXBH-1724?07J 5.4/7.2 1/60 2-3.6 SINGLE 26.0/30.0 1.7 1 35/40 35/40 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40.0 1.7 46/53 50/60 1817ST/ RXBH-1724A13J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1. 1.7 59/68 60/70 2417ST RXBH-1724A13J 3.1/4.2 1/60 1-4.17 MULTIPLE CKT 1 15./17.4 1.7 21/24 25/25 6.3/8.3 1/60 2-4.17• MULTIPLE CKT 2 30.1/34.7 0.0 38/44 40/45 RXBH-1724A07C 5.4/7.2 3/60 3-2.4 SINGLE 15.0/17.3, 1.7 21/24 25/25 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20.0/23.1 1.7 28/31 30/35 RXBH-1724A13C 9.4/12.5 3/60 3-4.17. SINGLE 26.1/30.1 1.7 35/40 35/40 RXBH-1724?03J 2.25/3.0 1/60 1-3.0 SINGLE 10.8/12.5 2.5 17/19 20/20 RXBH-1724?05J 3`6/4.8 1/60 1 -4.8 SINGLE 17.3/20.0 2.5 25/29 25/30 RXBH-1724?07J 5.4/7.2 1/60 '2-3.6 SINGLE 26.0/30.0 2.5 36/41 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40.0 2.5 47/54 50/60 RXBH-1 724A1 3J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1 2.5 60/69 602/70 RXBH-1724A13J 3.1/4.2 1/60 1-4.17 MULTIPLE CKT 1 15.0/17.4 2.5 22/25 25/25 6.3/8.3 1/60 2-4.17 MULTIPLE CKT 2 30.1/34.7 0.0 38/44 40/45 RXBH-1724A15J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60.0 2.5 68/79 70/80 RXBH-1724A15J 3.6/4.8 1/60 1-4.8 MULTIPLE CKT 1 17.3/20.0 2.5 25/29 25/30 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 3017ST/ RXBH-1724A18J 12.8/17 1/60 3-5.68 SINGLE 61.6/70.8 2.5 81/92 90/100 3617ST RXBH-1 724A1 8J 4.3/5.7 1/60 1-5.68 MULTIPLE CKT 1 20.5/23.6 2.5 29/33 30/35 8.7/11.3 1/60 2-5.86 MULTIPLE CKT 2 41.1/47.2 0.0 52/59 60/60 RXBH-1724A07C 5.4/7.2 3/60 3-2.4 SINGLE' 15.0/17.3 2.5 22/25 25/25 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20.0/23.1 2.5 29/32 30/35 RXBH-1724A13C 9.4/12.5 3/60 3-4.17 SINGLE 26.1/30.1 2.5 36/41 40/45 RXBH-1724A15C 10.8/14.4 3/60 3-4.8 SINGLE 30.0/34.6 2.5 41/47 45/50 RXBH-1724A18C 12.8/17.0 3/60 3-5.68 SINGLE 35.5/41.0 2.5 48.55 50/60 RXBH-17A07D 7.2 3/60 2-3.6 SINGLE 8.7 1.4 13 15 RXBH-17A10D 9.6 3/60 3-3.2 SINGLE 11.6 1.4 17 20 RXBH-17A15D 14.4 3/60 3-4.8 SINGLE 17.3 1.4 24 25 RXBH-17A18D 17 3/60 3-5.68 SINGLE 20.4 1.4 28 30 RXBH-1724?05J 3.6/4.8 1/60 1-4.8 SINGLE 17.3/20.0 2.5 j 25/29 25/30 RXBH-1724?07J 5.4/7.2 1/60 2-3.6 SINGLE 26.0/30.0 2.5 36/41 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40.0 2.5 47/54 50/60 RXBH-1724A13J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1 2.5 60/69 602/70 3621ST RXBH-1724A13J 3.1/4.2 1/60 1-4.17 MULTIPLE CKT 1 15.0/17.4 2.5 22/25 25/25 6.3/8.3 1/60 2-4.17 MULTIPLE CKT 2 30.1/34.7 0.0 38/44 40/45 RXBH-1 724A1 5J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60.0 2.5 68/79 70/80 RXBH-1724A15J 3.6/4.8 1/60 1 4.8 MULTIPLE CKT 1 17.3/20.0 2.5 25/29 25/30 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 RXBH-1724A18J 12.8/17 1/60 3-5.68 SINGLE 61.6/70.8 2.5 81/92 90/100 •Supply circuit protective devices may be fuses or"HACR"type circuit breakers. •Largest motor load is included in single circuit and multiple circuit 1. •H non-standard fuse size is specified,use next sae larger standard fuse sue. •J voltage(2301)single phase air handler is designed to be used with single or three phase 230 vok electric heaters:In the case of connecting 3-phase power to the air handler terminal block without the heater,bring only two leads to the terminal block cap,insulate and fully secure the third lead. [ ]Designates Metric Conversions COMFORT13INTEGRATED HOME 1 Air Electrical Data RH1P Series Electrical Data -With Electric Heat (Cont.) Installation of the U.L.Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler ,. Heater kW No.Elements Type Supply - Circuit Motor- Minimum Maximum Model Heater Model No. '(208/240V) PH/H2 kW Per Circuit Single Amps. Ampacity `Circuit Circuit { RH1P (480V) Circuit Multiple Ampacity Protection 4221ST/ RXBH-24A18D 17.0 3/60 3-5.68 SINGLE 20.4 2.2 29 30 4821ST/ RXBH-24A20D 19.2 3/60 6-3.2 SINGLE 23.2 2.2 32 35 4824ST RXBH-24A25D(4-ton only) 24.0 3/60 6-4.0 SINGLE 28.8 2.2 39 40 RXBH-1724?05J 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20.0 5.2 129/32 30/35 RXBH-1724?07J 5.4/7.2 1/60 2-3.6 SINGLE 26.0/30.0 5.2 39/44 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40.0 5.2 50/57 50/60 RXBH-172015J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60.0 5.2 72/82 80/90 RXBH-1724A15J 3.6/4.8 1/60 1-4.8 MULTIPLE CKT 1 17.3/20.0 5.2 29/32 30/35 } 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 RXBH-1724A18J 12.8/17 1/60 3-5.68 SINGLE 61.6/70.8 5.2 84/95 90/100 RXBH 1724A18J 4.3/5.7 1/60 1-5.68 MULTIPLE CKT 1 20.5/23.6 5.2 33/36 35/40 8.7/11.3 1/60 2-5.86 MULTIPLE CKT 2 41.1/47.2 0.0 52/59 60/60 RXBH-24A20J 14.4/19.2 1/60 4-4.8 SINGLE 69.2/80 5.2 93/107 100/110 RXBH-24A20J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 1 34.6/40.0 5.2 50/57 50/60 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 RXBH-24A25J 18.0/24.0 1/60 6-4.0 SINGLE 86.4/99.9 5.2 115/132 125/150 6.0/8.0 1/60 2-4.0 MULTIPLE CKT 1 28.8/33.3 5.2 43/49 45/50 RXBH-24A25J 6.0/8.0 1/60 2-4.0 MULTIPLE CKT 2 28.8/33.3 0.0 36/42 40/45 6.0/8.0 1/60 2-4.0 MULTPLE CKT 3 28.8/33.3 0.0 36/42 40/45 RXBH-24A30J 21.6/28.8 1/60 6-4.8 SINGLE 103.8/120 5.2 137/157 150/175 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 1 34.6/40.0 5.2 '50/57 50/6 F RXBH-24A36J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 6024ST 7.2/9.6 1/60 2-4.8 MULTPLE CKT 3 34.6/40.0 0.0 44/50 45/50 t RXBH-1724A07C 5.4/7.2 3/60 3-2.4, SINGLE 15.0/17.3 5.2 26/29 30/30 1 I RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20.0/23.1 5.2 32/36 35/40 RXBH-1724A15C 10.8/14.4 3/60 3-4.8 SINGLE 30.0/34.6 5.2 44/50 45/50 RXBH-172018C 12.8/17.0 3/60 3-2.84 SINGLE 35.6/41.0 5.2 51/58 60/60 RXBH-1724A18C 6.4/8.5 3/60 3-2.84 MULTIPLE CKT 1 17.8/20.5 5.2 29/33" 30/35 6.4/8.5 3/60 3-2.84 MULTIPLE CKT 2 17.8/20.5 0.0 23/26 25/30 t RXBH-24A20C 7.2-9.6 3/60 3-3.2 SINGLE 40.0/46.2 5.2 57/65 60/70 RXBH-24A20C 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 1 20.0/23.1 5.2 32/36 35/40 f 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 2 20.0/23.1 0.0 25/29 25/30 RXBH-24A25C 18.0/24.0 3/60 6-4.0 SINGLE 50.0/57.8 5.2 169/79 70/80 I ) RXBH 24A25C 9.0/12.0 3/60 3-4.0 MULTIPLE CKT 1 25.0/28.9 5.2 '38/43 40/45 9.0/12.0 3/60 3-4.0 MULTIPLE CKT 2 25.0/28.9' 0.0 32/37 35/40 RXBH-24A07D 7.2 3/60 2-3.6 SINGLE 8.7 2.2 14 15 RXBH-24A10D 9.6 3/60 3-3.2 SINGLE 11.6 2.2 18 20 r RXBH-24A15D 14.4 3/60 3-4.8 SINGLE 17.3 2.2 25 25 RXBH-24A18D 17.0 3/60 3-5.68 SINGLE 20.4 2.2 29 30 RXBH-24A20D 19.2 3/60 6-3.2 SINGLE 23.2 2.2 32 35 RXBH-24A25D 24.0 3/60 6-4.0 SINGLE 28.8 2.2 39 40 RXBH-24A30D 28.8 3/60 6-4.8 SINGLE 34.6 2.2 46 50 t •Supply circuit protective devices may be fuses or"HACK"type circuit breakers. I •Largest motor bad is included in single circuit and multiple circuit 1. •H non-standard fuse size is specified,use next size larger standard fuse size. •J Voltage(23oV)single phase air handler is designed to be used with single or three phase 230 volt electric heaters.In the case of connecting 3-phase power to the air handler terminal block without the heater,bring only two leads to the terminal block rap,insulate and fully secure the third lead. t [ ]Designates Metric ConversionsINTEGRATED HOME COMFORT 15 r t } 3 Air Electrical Data '0 RH1 P Series Electrical Data -With Electric Heat (Cont.) Installation of the U.L.Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Heater kW No.Elements Type Supply Circuit Motor Minimum Maximum Model rcuit Circuit RH1P, Heater Model No. (2(480V)V) PH/HZ kW Per Circit Single Circuit Multiple Amps. Ampacity Ampacity Protection RXBH-1724A18J 4.3/5.7 1/60 1 -5.68 MULTIPLE CKT 1 20.5/23.6 2.5 29/33 30/35 8.7/11.3 1/60 2-5.86 MULTIPLE CKT 2 41.1/47.2 0.0 52/59 60/60 RXBH-1724A07C 5.4/7.2 3/60 3-2.4 SINGLE 15.0/17.3 2.5 22/25 25/25 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20.0/23.1 2.5 29/32 30/35 RXBH-1724A13C 9.4/12.5 3/60 3-4.17 SINGLE 26.1/30.1' 2.5 36/41 40/45 3621ST RXBH-1724A15C 10.8/14.4 3/60 3-4.8 SINGLE 30.0/34.6 2.5 41/47 45/50 RXBH-1724A18C 12.8/17.0 3/60 3-5.68 SINGLE 35.5/41.0 2.5 48.55 50/60 RXBH-17A07D 7.2 3/60 2-3.6 SINGLE 8.7 1.4 13 15 RXBH-17A10D 9.6 3/60 3-3.2 SINGLE 11.6 1.4 17 20 RXBH-17A15D 14.4 3/60 3-4.8 SINGLE 17.3 1.4 24 25 RXBH-17A18D 17 3/60 3-5.68 SINGLE 20.4 1.4 28 30 RXBH-1724?05J 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20.0 5.2 29/32 30/35 RXBH-1724?07J 5.4!1.2 1/60 2-3.6 SINGLE 26.0/30.0 5.2 39/44 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8, SINGLE 34.6/40.0 5.2 50/57 50/60 RXBH-1724A15J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60.0 5.2 72/82 80/90 3.6/4.8 1/60 1-4.8 MULTIPLE CKT 1 17.3/20.0 5.2 29/32 30/35 RXBH 1724A15J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 RXBH-1724A18J 12.8/17 1/60 3-5.68 SINGLE 61.6110.8 5.2 84/95 90/100 4.3/5.7 1/60 1 -5.68 MULTIPLE CKT 1 20.5/23.6' 5.2 33/36 35/40 RXBH-1724A18J 8.7/11.3 1/60 2-5.86 MULTIPLE CKT 2 41.1/47.2 0.0 52/59 60/60 RXBH-24A20J 14.4/19.2 1/60 4-4.8 SINGLE 69.2/80 5.2 93/107 100/110 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 1 34.6/40.0 5.2 50/57 50/60 RXBH-24A20J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40.0 0.0 44/50 45/50 RXBH-24A25J(4-ton only) 18.0/24.0 1/60 6-4.0 SINGLE 86.4/99.9 5.2 115/132 125/150 6.0/8.0 1/60 2-4.0 MULTIPLE CKT 1 28.8/33.3 5.2 43/49 45/50 4221ST/ RXBH-24A25J 6.0/8.0 1/60 2-4.0 MULTIPLE CKT 2 28.8/33.3 0.0 36/42 40/45 4821ST 6.0/8.0 1/60 2-4.0 MULTPLE CKT 3 28.8/33.3 0.0 36/42 40/45 4824ST RXBH-1724A07C 5.4!1.2 3/60 3-2.4 SINGLE 15.0/17.3 5.2 26/29 30/30 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20.0/23.1 5.2 32/36 35/40 RXBH-1 724A1 5C 10.8/14.4 3/60 3-4.8 SINGLE 30.0/34.6 5.2 44/50 45/50 RXBH-1724A18C 12.8/17.0 3/60 3-2.84 SINGLE 35.6/41.0 5.2 51/58 60/60 4.3/5.7 3/60 3-2.84 MULTIPLE CKT 1 17.8/20.5 5.2 29/33 30/35 RXBH 1724A18C 8.7/11.3 3/60 3-2.84 MULTIPLE CKT 2 17.8/20.5 0.0 23/26 25/30 RXBH-24A20C 7.2-9.6 3/60 3-3.2 SINGLE 40.0/46.2 5.2 57/65 60/70 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 1 20.0/23.1 5.2 32/36 35/40 RXBH 24A20C 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 2 20.0/23.1 0.0 25/29 25/30 RXBH-24A25C(4-ton only) 18.0/24.0 3/60 6-4.0 SINGLE 50.0/57.8,_ 5.2 69/79 70/80 RXBH-24A25C(4-ton only) 9.0/12.0 3/60 3-4.0 MULTIPLE CKT 1 25.0/28.9 5.2 38/43 40/45 9.0/12.0 3/60 3-4.0 MULTIPLE CKT 2 25.0/28.9 0.0 32/37 35/40 RXBH-24A07D 1 7.2 3/60 2-3.6 SINGLE 8.7 2.2 14 15 RXBH-24A10D 1 9.6 3/60 3-3.2 SINGLE 11.6 2.2 18 20 RXBH-24A15D 1 14.4 1 3/60 3-4.8 SINGLE 17.3 2.2 25 25 •Supply circuit protective devices may be fuses or"RACR"type circuit breakers. •Largest motor bad is included in single circuit and multiple circuit 1. •If non-standard fuse size is specified,use next size larger standard fuse size. •J Voltage(23oV)single phase air handler is designed to be used with single or three phase 230 volt electric heaters.In the case of connecting 3-phase power to the air handler terminal block without the heater,bring only two leads to the terminal block cap,insulate and fully secure the third lead. [ ]Designates Metric Conversions 14 INTEGRATED HOME COMFORT Air General Data/Electrical Data 0 RA14 Series Physical Data PHYSICAL DATA Model No. RA1418A RA1424A RA1430A RA1436A RA1442A RA1448A RA1460A Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 r Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 1 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz) 68 72 93 112 119 135 162 � Compressor Type Scroll Outdoor Coil 1 Net face area-Outer Coil 9.1 11.1 12.1 14.8 16.1 18.9 21.5 Net face area-Inner Coil - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 20 20 20 20 20 20 20 Outdoor Fan Diameter-in. 20 20 20 24 26 26 26 Number of blades 2 2 2 3 2 2 3 ' Motor hp 1/10 1/8 1/5 1/6 1/5 1/10 1/5 CFM 2225 2505 2605 3105 4265 4265 , 4140 RPM 1075 1070 1075 850 820 820 850 watts 130 163 142 173 240 236 255 Shipping weight-Ibs. 125 125 148 157 199 200 210 Operating weight-Ibs. 1 122 125 141 150 1 192 1 192 202 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)2 20 25 25 30 40 45 50 Minimum circuit ampacity3 13 15 17 19 30 26 40 Compressor Rated load amps 9.7 11.2 12.8 1 14.1 17.9 19.9 1 23.7 Locked rotor amps 46 60.8 64 1 77 112 109 1 152.5 Condenser Fan Motor Full load amps 0.6 0.7 0.7 0.6 1 1 1 Locked rotor amps 1.1 1.2 1.3 1.5 2.3 2.3 2.3 Line Voltage Data (Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-61 208/230-3-62 208/230.3-63 Maximum overcurrent protection(amps)2 - - - 20 30 30 35 Minimum circuit ampacity3 - - - 12 18 18 21 Compressor Rated load amps - - - 8 1 13.2 1 13.1 1 15.9 Locked rotor amps - - - 71 1 88 1 110 1 - 110 Condenser Fan Motor Full load amps - - - 0.6 1 1 1 Locked rotor amps - - - 6.5 2.3 2.3 2.3 Line Voltage Data (Volts-Phase-Hz) - - - 480-3-60 480-3-60 480-3-60 480-3-60 Maximum overcurrent protection(amps)2 - - - TBD TBD TBD TBD ' I 3Minimum circuit ampacity - - - TBD TBD TBD TBD a Compressor ) Rated load amps - - - TBD TBD TBD i TBD Locked rotor amps - - - TBD TBD TBD TBD Condenser Fan Motor Full load amps - - - TBD TBD TBD TBD Locked rotor amps - - - TBD TBD TBD TBD j { 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. i 8 E-On INTEGRATED HOME 1 COMFORT r Accessories/Weighted Sound Power/Thermostats Air 'a RA14 Series Accessories Model No. RA1418 RA1424 RA1430 RA1436 RA1442 RA1448 RA1460 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-AO8 RXAD-AO8 RXAD-A08 RXAD-AO8 RXAD-AO8 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 61-20ORD2T3TVLC 61-20ORD2T3TVLC 61-20ORD2T3TVLC 61-200RD2T3TVLC 61-20ORD2T3TVLC 61-20ORD3T3TVLC 61-200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 61-200RD2T3TVLC 61-200RD2T3TVLC 61-200RD2T3TVLC 61-20ORD2T3TVLC 61-200RD2T3TVLC 61-200RD3T3TVLC 61-20ORD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V I 61-AMG120/240V 61-AMG120/240V I 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 91-101123-21 1 91-101123-21 1 91-101123-21 1 91-101123-21 91-101123-21 91-101123-21 91-101123-21 _ 'Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) A-WEIGHTED SOUND POWER LEVEL(dBA) Unit Size-Voltage,Series Standard Rating TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) (dBA) 125 250 500 1000 2000 4000 RA1418A 76 52.9 61.1 65 65.7 62.7 58.1 RA1424A 75 52.6 59.3 65.3 65.7 62.4 57.9 RA1430A 74 48.8 57.5 63.5 64 61.9 56A RA1436A 76 51.6 57.5 64.3 67.6 64.9 58.6 RA1442A 76 54.9 61.5 65.3 66.3 62.8 59.5 RA1448A 76 - 52.3 59.1 66.7 1 65.7 62.4 59.3 RA1460A 75 53.4 59.1 65.9 1 66.9 ' 62.8 58.7 , NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) Thermostats 200-Series y Programmable 000� (i 300-Series 7 500-Series 1 + w l F � tk Deluxe 12' Communicating/ Programmable Programmable .-z :9' � 400-Series Special Applications/ n' Programmable Brand Dascripter Sart„ System Type (3 Characters) (3 Cheraeters) (2 Characters) (2 Characters) RHC TST 213 LIN MS 200=Programmab1e GE-GatlElecbk 300=..1-Programmable UN=Unhand(ACMP/GE) RHC-Rheum TST-The-tet 400 SSBI Apaicat!r/ MD-Modulatln0 Pomata ss-��te0e Programmable DF Pmgrammabk -Dual Fuel MS=MUItl-Stage 500-communicabng/ CM-Communintlng Photos are representative.Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T11-001. COMFORT75 INTEGRATED HOME Conditional 10 Year Warranty Consumer Warranty Confirmation The new degree of comfort:" /= Pro`duct Information 9 ; .\ Q Model Serial Registration Date Install Date RA1442BJ 1 NA W321739867 2/22/2018 1/19/2018 �.. RH1P4221STANJAUSA W481721144 2/22/2018 1/19/2018 t `Z— Customer Information Contractor Information First Name MICHAEL A Name ARS/Miami Last Name PALUCH . j. Email , Email cmcinnis@ars.com Phone 305-282-6336 Phone (305)235-7223 Address 1291 NE 96 ST Address 18720 SW 108th Ave City MIAMI SHORES City Miami ' �.' State FL State FL Postal Code 33138 Postal Code 33157-6377- ❑ —' Opp \\\ •�i�: 11 11 tl //OF 11 11 rl t/ 11 /t ��� f 1 MIAMI-DADE MIAMI-DADE COUNTY w PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 i DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 l NOTICE OF ACCEPTANCE (NOA) www.rniamidade.gov/economy Rheem Sales Company,Inc. i a r 5600 Old Greenwood Rd. Fort Smith,AR 72917 t 1 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). , This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control 1 Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may t immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control r Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. a DESCRIPTION:Mechanical Unit Steel and Aluminum Tie-Down Clips for Grade and Rooftop # Applications APPROVAL DOCUMENT: Drawing No. 15-2543GA and 15-2564RE,titled"Wind Load Certification of I Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips:At Grade and Roof Mounted Applications",sheets 1 through 7 of 7,dated 05/14/2015,revised on 11/20/2015,prepared by Engineering Express, signed and sealed by Frank L.Bennardo,P.E.,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None S LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city, state, model/series,and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.MMisuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. { ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done i in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-0903.08 and consists of this page 1 and evidence page E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No. 16-0712.07 MIAMI-DAD;COUNTir Expiration Date:February 25,2021 Approval Date: July 28,2016 Page 1 Rheem Sales Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Submitted under NOA #15-0903.08" 1. Drawing No. 15-2543GA and 15-2564RE,titled"Wind Load Certification of Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips: At Grade and Roof Mounted Applications", sheets 1 through 7 of 7, dated 05/14/2015,revised on 11/20/2015, prepared by Engineering Express, signed and sealed by Frank L. Bennardo, P.E. B. TESTS "Submitted under NOA #15-0903.08" ' 1. Test report on Uniform Static Air Pressure Test per FBC, TAS 202-94 along with marked-up drawings and installation diagram of Rheem RA Series Mechanical Units, prepared by, American Test Lab of South Florida, Test Report No. 0323.01-15, dated 05/18/2015, signed and sealed by Stephen W. Warter,,P.E. C. CALCULATIONS "Submitted under NOA # 15-0903.08" 1. Anchorage calculations prepared by Engineering Express,dated 11/20/2015, signed and sealed by Frank L.Bennardo,P.E. a D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT "Submitted under NOA #15-0903.08" 1. Statement letter of code conformance to the 5h edition(2014) FBC issued by Engineering Express, dated 08/24/2015, signed and sealed by Frank L. Bennardo, P.E. 2. Statement letter of no financial interest issued by Engineering Express, dated 11/20/2015, signed and sealed by Frank L. Bennardo, P.E. 3. Distributor agreement dated 11/12/2015. 07/t4/2,0/4 Carlos M.Utrera,P.E. Product Control Examiner NOA No.16-0712.07 Expiration Date:February 25,2021 * Approval Date: July 28,2016 E-1 i 3 r RHEEM SALES COMPANY, INC. WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE-DOWN CLIPS:AT GRADE MOUNTED APPLICATIONS,a / 0.313'' II I APPROVED DESIGN t •'� "OT'''TFYrC'ry'/{1�-D.]sD' 60 PSF LATERA.off, u' CRITERIA: 1.1_ WIND LOAD �,F' it �+ZjSTOM,P�.� Zs,S:FA� Ux11j5.+NJ''� zvN s4�G�]I O - ,/N ,�'!'�'�f s �<i' flno DESIGN NOTES: Z 1N-GA ASTM BRe.SPECIFIC PRESSURE REOVIREMEHTS AS DETERMINED W ACCORDANCEW1iA653 PAINTED WIM ASR>•10 ANDCnpPIE0.1A OF THE RORIDA eURDINO CODE SHALL WuSTEEL SE 1£55 THANOREQUALTOTHEDESIGNPRESSURECAPACITYVAUES LISTED HEREIN FOR ANY ASSCMOLY]5 SHOWN.DESIGN PRESSURE 3BI.T SIM.TO.A)BUT REQUIREMENTS SHALL BE DETERMINED BY A REGISTERED DESIGN 3 C•• ON UN.FACf k 0:1 DIT•.%ACT $ PROFESSIONAL ON A 3OB-SPECIFIC OASLS IN ACCORDANCE WITH THE li N0.18]' GOVERNING COOS- A ` GENERAL NOTES: I D.JOS' O (.) T'P r t. M:S SYSTEM MAS BEEN DEIGN®AND SMALL EE FAB0.1CAlE0IN rZ., O FIL DANfI (I 4)- HISSU IFJAENTSOF USED RTHIHANDO CODE p CONCRETE CONCR a FIFlH EDrtION(1014).TITS SYST_N MAY BE USED WfIMN ANO WT20E Ll[ SUPPORTING SUPPORTING CERO"X PACT ESJST ICANE TONE.THIS DBI�TI IS NOT INTTRy. O STRUCTURE BY STRUCUR BY D CERTIFY IMPACT RESISTANCE OF THE peOHANIGLUNR CA9INETRY. OTHERS ISP. B OTHERS,Tri. CONTROLBO% 2. 10 11-1/3% M ALLOWABLE STRESS HAS BEEN USEO TN WE L DESIGN OF THIS SYSTEM. ^ {f 1 MECHANICAL UNIT z MECHANICAL UNIT 1---11.000 J. DBIGNRCFRTRICAnon OF TXERIANTESNETFI IS APPROVPLO—GH TESIREPORTp03T3.O1-15 MINIMM WEIGHT OF SOUMFIOP 0 qEt I ! 1 N.T9 FRONTISOMETRIC 1 N.T.S. BAIX ISOMETRIC TIE-DOWN CLIP 4, ALLDIMENSIONSANDTHE MIxiMUN WEIGXT(13018 MINOAt1M)OF C' MECHANICAL UNIT SMALL CONFORM TO LIMTATANS STATED PEREIN.ALL .(n t%%%FJ77 MECHANICAL SPECIFICATIONS(CLEAR SPACE,TONNAGE,ETC)SHALL BE J THESE ISOMETRICS ARE INTE4DED FOR AS PER MANUFACNR ER RECO MMMDAnONS ANO METHE IXPRESS MCMI TECH CLIP:vIGA(0.07•) Q i DGGRAMMATI[AL MIRPOSES ONLY•,ALTERNATE RNFEM �tlp gei7TA g653—SO KSI STEEL RFSWNSIBrtITT'OF THEWMMCTOR. W TL UNITS LISTED HEREIN MAY YARY IN APPEARANCE '�4. 5. TAPCONS REFERRED TD NESEiN SHALL OE RW BURDE%BPAND.SAF GRADE PINAf (QSTDB)OR D.OBD•5051-X33 5,INSTALLED TO 3000 P51 MIN CONCRETE SEE ANCHOR SCHEDULE Po0. ALUMINUM(ELITOAe),P.ANT ccc (2}I30 NTERNAL POST TECH KR f RRCROSMK OR ANCaR REQWREMENIS.ALL SHEET METAL SCREWS USED TO FASTEN -W SMS PER AVACENT TQ mww RRCUIDASMK CLIPS IO MECHArvuGLUNR55XALL BE RIO(11 MIN THREADS IERINCH) W CTP,VP. CONTROL BO% GRADE S ONLY.PROVAE(5)PITCHES MINIMUM PAST WETHREAD MANE _ FaI Ily SHEET METAL SCRENS-AIL FASTENERS SMALL HAVE APPROPRR TE t CHER COR0.0SIOR PROTECTION M PREVENT @ECTROLYSIS. PANEL, E. ALL CMWMJ,SPECIFIED CONCRETE 15 NOT PART OF THIS CEATFICATIMIN F TLP. ' _,•.~_ ASAM ETE,ALL WNCREIESHALLBE STRUCRIPAL fxM1ICPETCTNTN. Al 00 DO 331.25' THICK AIA SHALL NAVE MINIMUFI COMPRESSIVE SINENGIH OF 3000151, IP© UNLESS NOTED OMIRW6E ANCHOR PER �O PANIT N CASE pO PUNIT AN BASE PAN BASE 0 ). INE CONTAAC'OR LS RESPONSIBLE TOINSVUT S MENBEILS FROM E D[$SIM.—MATERGLS 13 PREVEYT N2CC ROLYSI3. �e B. FLECTLICALGROUND,WHO REQWRm,TO BE DEIGNED B DISTAWD W SCHEDULE PRODUCT REVISED oTIm6. — p1yln�mm tM FbNdR 9. ADEQUACY OF ANY IX6ITNG ST0.UCIVRETO W0/6TAND •. 1' Sulitllno Lod �PQD SUPERIMPOSED LOADS SHALL BE WRIM D W We IDS `ONlIXC �! MOA- 15-0712,07 PPOFESSIO"LAND 15 NOT INCWOED IN TH6 CERTTPIfATiON.E%CEPFAS �ISp ]OW PSiNM ='+'-� • S •T: E%PRESSLYPNOVIDEDMEREIN,NOADDTTONALCERTLFICATIONNM uu CONCRETE BY [:apintb to 0212512021 AFFIRMMtONS AREDTTVTDED, i I a OTHERS•TYP' O O8c© •(ED) �y Y DM.L O 10.THE SYSTEM CETAILEO HEREIN 1S GENERG AND DOES NOT PROVLDE 11 Ge LL IMMRMATTON FOR A SP "IC SM.FORSTIEMM 1ONSDIFFERENT 6 4 ®B®ARE SIM Mla t anbo I CONTROL FRON THE CONDITIONS DETAILED HEREIN,A LICENSED IDIMNOR OR 4 AND OCQI0.0T1 LIP CFFSET.DUtEN510NSHALL, v ,�, y-.-._._._._ REG6TEAED MCHTTBCT SHAH PREPARE SRE SPECIFIC OOWMENIS WR DPP.FACES EE T�NfN FROM THIS SIDE ONLT�- - USE IN CCN/U4CTION WITH THIS DOLTIMMFT. DATUM CACP 11.WATER-nGHMFSS OF IXISTNG HOST SUBSTRATE SHALL BETHE RRL 3 TIE DOWN CLIPS ROMHSTSJL 0 WE1NSTALLING—TRACTDR.CONTRACTORS ON RAC DRSHILL 1 N.TS. ELEVATION 4 TIE-DOWN CLIP LAYOUT E16TME TUT qW NDMOV®OR ALTERm WATERPROOFIM1'G NEMBMI[IS" N.T.S RE51_AFTER FARRIGTIONANDWSTALIATANOF STU/CIU0.E OM>IRHIWI[LPfN1NPI F.e ], PIAN PACPOSmHEREMWISMINOR SHAILNOTBERESFON561EfORAW 15-2543GA WATERPRODr G OR 1EAKKE ISSUES YYHICI TUY OCCA AS WATER-TIGHTNESS SHALL OF THE FUILAESPONSIIIRRYDEME PaeBYOImHN1�7 ANCHOR SCHEDULE: TIE-DO N CLIP OFFSETS: APVLIGM11n+oDELS" msTAlInGCONTRAcaL W SUBSTRATES DESCRIPTION OIN.1 4.50•MA%OFFSET FROM DATUM FACE RAt318,RAjScLRA1D14 RA133B.RAUARA1114 CONCRETE: STEEL, I%fMI L EMBED TAPCON AR CARBON DIN.2 24.50•MIN OFFSET FROM[GTA FACE RAtIlA,MT4]O,RAtB14 (1•THIIX Nd, STEEL,1�'MILL EMB®TO CCNCRETB,3'MIN. DIM.J 25.25 MIN OFFSET FROM 0A'Ipl TACE RP141B,RP7121,RP1a]0, 3W0 PSI MINJ EDGY DISTANCE,]•M[N.SPACDIG TO ANY RP1614 fl0U14 RP1B1A, J & 0)ACENT ANCHOR. DIM.4 13'NA%OFFSR PROM[UNM FACE R014M e. I II 1 F F i 1 i' E I FFF I ( t J ' t I Lrf 1 1 RHEEM SALES COMPANY INC. �n1,1,1,1 11 41 __'�ee WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE-DOWN CLIPS:AT GRADE MOUNTED APPLICATltl9' ♦--}S.000' =* 0.46 g 4 0.313• [ .b: _Z —1 �-Daso•, 9 ��ATE ¢•, � onR Sm Py,� '3's��n"ca, Dortr•/.r��NAL E g e� d ✓�3'I _ N.. J�. t/,u, Q ////111111111 I'n `U�318-GA ASTM Z ggf. S03 PAINTEDF Q Q W� .a a7 3 tl G7 CABINETRYy F SIN. TO HCl BiP't 5[M.T(1 451" S Y UN VPP.FACE '•'" ON UPI'.1 ACE q A C o.16T 9 0.306' V CONRENCREBYTE _ 0 B OTHERS,,CONCRET y SUPPORTING SUPPORTING Q STRUC 'fYP. OTHERS,TYP. CONTROL BOX � 1 MECHANICAL UNIT z MECHANICAL UNIT X10°° u sC 1 N.T.s. FRONT ISOMETRIC 1 N.T.S. BAIX ISOMET0.tC TIE-DOWN CLIP Lu €3 THESE:SOMETRIcs ARE IMENOEO TA FOR FOOD 0 SMS PER CLIP FOR UNDs UP 01AGRAMMATICAL PVRPOSES VARY Bi3' TE RHEEM MTAMI TECH CLIP:1464 STEEL , TO 35'TALL TO 39- SMS PEA QIP UNTR lISTEo MFRS W MAY VARY IN APPEIRANCE ASTM 8)O Fu-0 K 0 STEEi VI t0 S FOR UNRS VP TO39'TALL(ONLY(2) AUMNOA0.090'TDAII),M I y SMS SHOWN BELOW) A XIT (CUCU1t,s MUR W VERNAL POST TECN KR t TDRS DSMK OR FFF CONTROL TO RA[UTOASMK o COATROL BO% i PAN PAN 0 _ 00 oo n� 435.25 „✓� ,. �� UNIT BA.Moo,, E Da UNIT BASE Q� NIT BASE u PAN I PAN 0 ANCHOR PE0. I 0 �0 � �po E3°0°PSI MIN. . . 1 i cONCREIE BY q o -?�— .... 3 OTHERS, O&© O Cl1 Dim.1 € ' ®w qRE yM _. _ I / CONTROL ee t AND OOCUR ON CLiP OFFSET DIMENSION SHBLL �,�j( �x_._ ` OPP,FACES R?'AfEr FA0M T-f.IS 503E ONLY (2)TIE-DOWN CLIPS pATUM�� 1 N.rs REVATION 4 TIE-DOWN CLIP LAYOUT P2PTw.LIRM�e•A / ' 1 N.T.s. PIAN `! i PRODUCT REVISED 15-2543GA APPLICABLE MODELS: ".,h •4l�1e ANCHOR SCHEDULE: TIE-DOWN CLIP OFFSETS: RA13°8,RA1a3B'RA14"B' '•°d O•~Ips « w Ed"v en•" sUlSTMTe OFBcaIPTtOxA7Oxo,MI348,W1+042R, Mow-Ne. '18.0712.07 ur 1 IXM.1 4.57 MAXMA%OffSET FROM DATUM FACE RP1336,RPI046,PP1436,RP1MR, CONCRETE: (1)-1/4'0 STW BU:IDEX TAPCON ATT CARBON IXM.2 26.D7 MIp OFFSET FROM DhTUM FACE RP1446,RP1330,RD1430,RP03B, eaM••x•• 0712512021 7 1 STEEL, ,FULL EMBED TO CONCRETE,3'MIN. RD1436,RPIN2,RD1442. h (9'TNIc1(MPI, DIN.3 29.07 YIN OFF5ET FROM DATUM FACE RNUA1T24,RAAU2036, 5 7000 PSI MIN.) EDGE DISTANCE,3'MIN.SPACENG TO ANY Alla _ LICE yc // E& PL]KENi ANCHOR. DIM.4 l3.°0'MAX OFFSET FROM DATUM FACE RNUA20]A RPA)P202,aPAlP1F38, L� AIAN1T36�RPA1P2D14 I 1 ) ( a F i 1 RHEEM SALES COMPANY, INC. ;`. .;RAR.o.P... WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE-DOWN CUPS:AT GRADE MOUNTED)PPLICATj { F' p-�-[�� .7 •. --� 0.113•'-J-,-� o.7sa• hyo: STATE,F[j € .n FCORI 1 �s �r5 I.zso '�'�,�`rs//� u;�801 { j5, 3. �,� s 3, Yr Q .,,,rr NAZI I ` O 0. L oa A653 ASTM W AINTF STEEL D 3 uwNETRv c=l� 1, km ON.TD(rACF siN.To F-E O • �. •� p ON OPD.eA B i n ON DPP.FACE tl A C 0.187• ) i U aj TE pTYP. 0 0 } r CONCRETE SUPPORTING SUPPORTIPPORTING ' STRIJCRIAE BY STRUCTURE BY p OTH.FRS,TYP. B OTHERS,7YP. CONTROL BOX 1 MECHANICAL UNIT z MECHANICAL UNIT rTl.000• o^� I N.T.S. FRONT ISOMETRIC 1 . K ISOMETRIC � NT.S. BATIE-DOWN CLIP THESE ISOMETRICS ARE IN, ED FOR OIAGRAMMATIGL RIRPOSES ON L Y; ALTERNATE RHEEM UN[TB LISTED NERETN MAY VARY IN APPEARANCE MIAMI TECH CLIP;14GA(OW) ASTM A653 FU-90 KSI STEEL I (CUTOB)OR 0.080'S0534132 W B (2)-330 ERNAL POST ALUMINUM(CUTOAB),MIAMI { W 3FIa SMS PFA ADJACENT TO TECH XR l RRCUTOSMK OR SOP IP,TTP. OONTPOL BOX R0.CUIDASMK 1L-- WER ;E I tANSL C 0� 0ANCHORPER OO PAN BASE BASE �O PAN BASE al B g SCHEDULE O 3000 PSI MIN. CON a BY aTTTEns,TTP. © O&o O at— DIN.1p - ®n p PRt sIM '� coNrnoL 1 I d ANOOCCURON CLIPOFFSETDIMENSION 51'WLL._._l_ OPP.FACES BE TAKEN FROM THIS SIDE.10 DATUM FACE 3 TIE-DOWN CLIPS N.T.S. ELEVATION 4 TIE-DOWN CLIP LAYOUT m�7mBgwRlpPwoPIE 1 1 N.Ts• 15-2543GA PRODUCT REVISED c APpwRns .r�T R ANCHOR SCHEDULE:, APP KAaE.ucDELs wIMmPIHnRwitnlMPloNsa oRR G cu.nm TIE-DOWN CLIP OFFSETS: BRIM R„,4,, HOA-ft.�uJ� te-OT+z.OT SunSTRATE DESMPTION DIM.t 4.SlY MA%OFFSEi FROM DATUM FACE RA1ue,RAIMM. a CONCRETE: (1}3/4'B ITW BUILDEX TAPWN ATT CROON p1M.2 30.lXY M[N OFFSET FROM DATUM FACE RAIBM,M1m8A, eRPtrat n7 STEEL,lV4'RILL EMBED TO CONCRETE,3'MM. WP DTB, N IV THICR MIN, DIM.3 31.00•MIN ORSET FROM oAT11M iPCE 8 23 ' S 1000 PSI NIp) EDGE DISTPNCE,3'MIN.SPARNG TO ANY SS ADJACENT ANCHOR. DIM.4 13.00'MAY OFFSET FROM DATUM FACE MIRm onlro 4 � t 1 1 d r 1 f t { Y r 1 t � t e I RHEEM SALES COMPANY, INC. WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE-DOWN CLIPS:AT GRADE MOUNTED APPLICAj O..S JR 75.3TNAY'� 35'h. 1 Lyhj51MY' m ss 0.313• o.Tso• 90., MATE, f c 3s. "ERY 35 h4k I.ss "F ORID y y �•'ns��NAL1j1 UPI1BG4ASTM Or �� A653 PAINTED O U Z 4x N I N CAMNEI(Y W E 0 0 Lu ;� S:M.1"O LC130 GIH,ro(A1141T O $ s i 'y3s"_q On OPP,MCF- D O-1— U • A C O.1RT 0 CONCRETE O 0 CONCRETE sUPPORTINc SUPPORRNG STRUCTLRE BY 0.3M. STRUCM(E BY [3 O Hms,TYP. CONTROL EO% p TY?. (J g C I OTNFAS,TYP. 1 MECHANICAL UNIT Z MECHANICAL UNIT F—fl.ocT 1 N.TS. F0.0NTISOMETR:C 1 N.T.S. MC%ISOMETRIC TIE-DOWN CLIP N O8 I THEE ISOMETRICS AAE INTENDED FOR W g DIAGRAMMATlCAL PURPDSES ONLY•,ALTERNATE RMEEM MNMl TECH CLIP:14GA(..Or)ASTN m6 tt � UNITS LISTED HEREIN MAY VARY IN APPEA]UNiCE N-90161 STCCL(CUTO10)OR(I 5 (4)-110 INTFRNALPOST 505211:2 AlLNNTM(CUFDAIO),MIAMI ££$ SMS PER {AO]ACENT TO TECH OT I RRCUTI%1(OR pACUTDAU( uii,tt3P,NP. GOM0.0L AO%� R43].25• C 0 NiT OASE UNIT[ISE ONIT MSE s;s ➢ ANCHDRPER PAN PAN PAN 3 pp 7 SCHEDULE „ n �� u�R. c/ 3000 PSE MEN. T OO ER[TE BY O •O cu DIM.I� p C. si d (S S Q ARE SIM CLIP OFFSETDIMENSION SHALL_ - --_0%_._ AND OCCUR ON C� SF} j BE TAKEN VAI MS SIOE(NDATUM FACE LV � 0".FACES a TIE-DOWN CLIP LAYOUT ..aw�MRn'iawL®AMx.A s TIE-DOWN CLIPS j 1 N.T.S. ELEVATION 1 N.T.S. PLAr1 PRODUCT REV13ED 15-2543GA ANCHOR SCHEDULE: TIE-DOWN CLIP OFFSETS: APPLICABLE" 3: °v"°"A °' `� ` L9. FAr;°•�'° "°" Bo�srRAn wm M=RIMOn xoaxs 16-071207 Dr. NDIM, 4SV MA%OTFSET FROM DATUM FACE RP=, MIN°,RA10E0•RP10E0, EIDIST W50xsA0XGRptTi •wR m RP14A0,RPi5D1,R0,RhkJAP15[0, lRpinxenR R02l25I2021 v7 COn:RE'fE,Y nm.OGE 01sTNKY.Y S.KiNOTbv AFaoR 3D.00'MIN OFFSET MOM DATUM FAGS RNUA2 R. T4l,RAM1IA1T00, j (t1 Uh•�GNlMM15Rft FOWFA5 Yn00t nil•Fw� mm mxu[Te.Y 31.00.11 OFFSET FROM DATUM FACE RA'VA20<S,RPAF"4A2011,0.RPA)P2M. sY S! ' sPPOE sP50.[MNJ I Oen RPNPITEQ RPAIP2D/E,RPNPNRO, Nia PrW uci CRn /a cnER sus.. Imam" n1n TTIM VS Op0.D®. 13.00`MAX OFFSET FROM DAVM FAC! �Lf EffXE0.ANCNOP ntOM 1X15..—E-1 TE YEeR X.R , T I P 1 J � i i 1 I 1 -.•. nnARDo,r.z I RHEEM SALES COMPANY, INC. ,,,.. II1,,IIII/l! WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL TIE-DOWN CLIPS: ROOF MOUNTED APPLICATI APPROVED DESIGN CRITERIA'11 *; 65 EAaaonveN �lr MT-A\ IMI - •O': �S,i,"' F z APPROVED DESIGN Z00 PSF;' �tY , 4 CRITERIA: — WIND L(3 NAL °^ [ UR 1•XA xoLL 100 P F UPLIFT5 <g yyy- fi[FTAaa p WIND LOAD WW mI=$�w .o pO (CONCURRENT) f'(" ;N jl • Rlrnm•.FwLNI. 'iEl/' .. rw nox�nP�w� pp �I I 2 MOUNT ISOMETRIC VIEW p i .. 0xT DI.A«50 DESIGN NOTES: u ; I I f nT,�AYgF.rDFAAxE 1 .. 4 Q p ,D� sRl6rEClFI[rnE55UEAAE oo IREMExK AS DEIERMXEDMn[iuxuAN[E wDM ? N P I NIMI M p .EQUIDAtA EDM I,MInP CIVV NO STD KA F.M IESTHMV I lcnKdAnd 1W'0"'On1AV— O0.(DUAIro TME SES o�IRWMECAPAOITYVNDQ IISTm MQF.W FdI ANY ' wLL wem loE nx em I xaEan n p F �sQxrusxDtLai moPesroMSDox i,l��smcewsm AccDIlNn er Q 8S i AA,e �%()1TMQ9P I �u� WRH IIII GDVFAM�OME a .. i XwBF Ti B�.pDRTF .T;YP. A,m_ GENERAL NOTES: ^FHM**m. er CMIFP CfwK 95YSRx MAS XE[M rncrxm AxO SHALLeE FRmIGTm WAraD0.0AXc! 1 MOUNT EXPLODED VIEW e�roTTMn* I,° p wlmmEREnnMHmsDRncrinAmAeNImNxGcmEFlRmmmon In �, 1 a,s. Woxr ISDMFr� a. Eiuw�iuur mxc mt�o[ilcnsls xo�inm,oDrn c,D�nn nn.ci�tr � ` �R� I �nYrMF 3 SUPPORT ANGLE '� V Ar¢EmmEFexxANluL unlrvalrvE,sr. ff33 1 .Ts. sEvxnax - ���L z Ra aanK WGB.sEW AucwAelt srRas Hns eFEn usED lnmenrslrx >I e ,X�, uNPMr eroA A M1FPBDA,P3noF-vseYA1+ENGNTesrueorsavmMalDA. o LLI TIE-DOWN CLIP LU F0 o NFOIAt1IGl UNITAV�LLNNiOMH IO LLMrtA3cxB SEATFOIEPP➢1.MA S $�Cr TlcN CTN MCA X[IwNGLSPECOXAT1IX6 R1PM PACE,TITWAGF,Erc.I BNALLXAS PQ E l=; IMNUFKlum0.0.FIIM1YENMTxIXS AxD AA[Ml30WF55 R6I�H"eODY Of ® F6,i I S�mETM AL[f�wSUSm TDFAST W0ME I QNXIGLUM g rveNlvwN' A fdMR • _ P08, PIIOL'1WOt SMLLBE P(IaMIXmWDB PFA WGn]OMD[55RPL00.mUNAI}j,T i IX1V.BOLTS Ufim TO rASEENAWMM.N AYGLLS TOEWPOM1nrvG FRAM OfY _L Be ASmi 34LO ST 1V 52 SI—KnUNAIEMAxD 8a 51NLL URI7Z SA!OMOF wA91E0.5\Nl?.MOVIDE(31 PDCI16 MNIMIM 1 MME IBY yyY�µ��,Y,w� PneT>�E TIMGD NANl fO0.5HEET HETALSCRflVS.ALL PS FASrmD65HMl t Ax01F,M � .uFeX xnYE TONIATE mRROS10X PnDTSIION TOHIT DFRROLYSIS.ALL RUMP mF rASENQ COXNFtDONST0 AWMINUM SMLL IOE hD1AYETGED6E �$I. +1� t ' a TIE-DOWN CLIP ATTACHMENTS Taw• nom. 4 LIMINBN AxOIFS SW:I;IFIEDHFAEW SMLLBE BBEKq AVkIMM otic. @ ; I 1 nls DLVAnom DxrvurlluiLsroBat-ri x nAwiuxu+wfr'�noi,rEmwxao..�• nI>,Ils.solrro•nrwAxltnra FIAxGE Al ATrAu«Exr rolrr.resauuxcear mEMrtASAsrM1ucTURw. �� Nrow�YUN.WOIE CENIEvm IExeQTO SUPPONT,NE'JxIT ASSEMBLY BNALLelPQ SLiAMT! i a.Ponrnuelo. - —_ TIE-DOWN CLIP OFFSETS: \DDI Ir-ete5:ooea� CQT6IGTIPI. qKKT!= •� �• LI� rgnT DIIR33 aEE aB.0SB'•XWEA x OaFFIFSsFTli IPII DAnWlrMxfrAAOlsE MRAIIM.RMAI34:'l M10s. MN24, 14MM1si REI,RP1424.R . RN8,RD141B,RP7524, B9.. TDEmLNrsEtECSmAmiNDINmWG1AULtIACMSCTAVT00OE0.LwfWRAA0mI,ASwBMEH%Fmd1P3nInRBMEINMO0UNf5Trn'roaFBnU[l,CNLTTro5UPNRDe[AIElYT2DXD6IAAwL1lf6MNNEFS.HDFABaN[ANDSu4FrUaAPcDAtsLryO.PBDr2 J t(}LCF[[ LD t0ADB 5Mu0evQVlm erlNE OrbIIE OESIG,1 ROFasoMLAIIDK xOY WU.UDm IXm1S C[0.rIFICAIWNF%C'RAS FAP0.6ELY NtlVIDIDHExEN, yD3 91fi R I® vMFUNj,nF.DM RD1424 mAODR10MLfFRNIGT10W50M1 NFlAIM eAx[INILWm. 21.� Y(� � ! 5 I £T— lt.mlSYeIEM OETAtIm HEPFW R4EPENC MID 006 MOr1nOVtoe ■� { ~ C � � i TM COMDRIWK OETAI!m MQEtx,ALnF1E®0WI14ll OlFi�� rurL0MIW1(LEBIWOBPA t 1 Dim.i w�D a Wmx AXrnnccrvwimErARe sln:sxaFs oazHFXK con uslW 15-2564RE PRODUCT REVISED Esr3xEcraF wLmTxK DocDlewr. ,a t mpM Mtll pf eleritl0. b� �M LL NAIQ-Tgalll iB Oi E%ISTxO MDSTARHIMAR9NMLrt,HE FULL 1TiA[EA f%RM7E?aBFOALY– GNNennG PAFNk euliaome p3si� M1NONSIeLLM OFMImTAWYG(OmMC100.CtwI0.ARD\EHALL CESPLF- L QSDpIj� dP EMUIIE LMTAMY nDIWEDMKTMED WAT[PF0.WiiXG MEMeMNFrs NDA-RD. 1"712.07 0.6TO0.E0 AE1F0.iAMICATIIXI AMD INSTALLAnOX OF STRIIERIREP0.CPOSm ', 5 TIE-DOWN CLIP LAYOUT w.r - NQEW. ,sQCWe sNALLwl.ER6PDry:IneFDnAX WAwwD XD lApiratbn 022`•'12021 DAITANAOELsal6mucHMrocmM1AswATQ-ncxrxlssbluuBFme �7 1 N.TS. HOIE' ficENIEFED MI PLAN y RRL 0.lSronslONl,OC m[ImTAIUNG t]BtRP.1CT00. E-1 AeOUTm! MATp PAIL 1`-7�/`1 Q aryannxG mMAe ler aTmF67 t NVOI j J I { i ll RuwBBExxx�J.P.B RHEEM SALES COMPANY, INC. zl:� WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL TIE-DOWN CLIPS: ROOF MOUNTED APPLICATI _ 1 v N x aw =y•. STATE of Z X J E I /'''1111111111111111 1 R I 00 RN ' /-2-\JMOUNT ISOMETRIC VIEW O M 1 I i tso 1 BBoc i I' i �.xxwmRwlE n.r9 —vu991.1 P+~o-- n� e Q �$ 1 � i i ...nrxnlxian"a m�''�`nxTnle UO � `�19 9erRq ` I i9wu EU9.n1 TFlM0.R M9 I xYwhu Y voE 0 0 RRRi i v F2 I �� a "R+artRwleEn. u) mxEx9l,w.. a i MOtc UNT EXPLODED VIEW SUPPORT ANGLE 9 i xT.9lPJM6d1E1xIC i xrs ea•�.nox W o Jx,<�,twx.EBnn9�`rt. 00 �$ a P roxr P� TIE-DOWN CLIP Eu+¢E..vV. Mx Wx�m. WvpRERURE,rv. uaPE 6T�LX'Iv%uxCUmM( ��. �9f a TIE-DOWN CLIP ATTACHMENTS 9 � i levxnae �$. 1 µ ,eJolxn•.w..vLaa 1F up iwRxxne a>nBlcP Es. j JrRPPOPr - TIE-DOWN CLIP OFFSETS: APPLICABLE MOML$ oOltw'a]1 u•sroalxgnoxTwUR iKe RAt]BA , RA84, M.RAIWB, RP133BPjl "431%RR1 30. vcw�S1. pn E.ta RDIOORPBKWA 115 p R1B20111fW 4, RDB,N"A2O24 Rhrtlw4[L_6 •et!R cora II RPAIPtnx,RPNP11x, PRODUCT REVISED �15-2564RE RANAITJ'a ' RPNPZ@x 1 991th IM N.M. A °' 9Pd� 1 -- DDd.l 0 0 ---- w.viiu.mn wml "Imm, '18-0772.07 Dis9 R !b m orsn oneaceM_ w_. suPromnx cm9re Ex lMi 02!23!2027 s rxxen moM,msimean. o"n"",� mx 5 TIE-DOWN CLIP LAYOUT RD cur mPalrtfmRED sy �� x90111REffiRMrO x/J. Mlw 9tlVe1 1 N.T.S. PIAN BI.wPDmvlBfrolff[01'01BR5♦ O i' , r t RHEEM SALES COMPANY, INC. ""'��9 WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL TIE-DOWN CLIPS: ROOF MOUNTED APPLICA101S��� 7 _T* Eaxoo®� STATE OF E 'o o°ir`.'w''nuer. Eanvmxuxin I I xaE �f1Im51f111W1`� Ill z v.mw I zQ rnuwcae c m z5 3 boco"o: E.ErnEn EEOEoan Z �o � t larsr°YR1ruiMwMaonre"Es .�y__ D nOn ianamxp 2 MOUNT ISOMETRI D eu�'r'Enxro"'" 1 x.rs. Isoierc-iso Z "wPonr^+Ear aorw•u I euw av�� DD x E Z gp L vssm e � .an EP.wEm _ 3 a 3 6 Mn M G 1 MOUNT EXPLODED VIEW 3 SUPPORT ANGLE 2 ...a .°xr.r Eaw�rlmnE,Mc 1 x.rs. .,�.•n,°x � �� TIE-DOWN CLIP $ . E 1.IA eeMxR xe"m. rM`�` ' q a�TIE-DOWN CLIP ATTACHMENTS �` a�,a•.arlawl-.lwnxr wMo 1)..r.S. Euvnnors , .. tl mlR.xcuwu,E�n.e°vr t( J ewPDmEnA"E7w. /"' TIE-DOWN CLIP OFFSETS: �f 1 r. _ oo" o;l R`. . nac nx o!ESEr Enos wnex Ena o.7r xJ s• k ENMESH � iPOM Wllxl M{E $ 9e� 1� Ex i m,n m nulaxrsti 0.125• .�Yt `II APPLICABLE MODELS: 0.216• T•n,e,•aewu'60.[EMEMf pp•Mafnw.ILRlNYD07E k `� a+• m "T RA MO.RA1u2A Ertw %ion iaxAx `E`f PRODUCT REVISED 15-2564RE L L RAIue,RA146D,Ra163q 1CT DIM.1 p ._ 1pp"S.�xmi RA161611 RPNP20]6, o"mc p0.1=n'Mx4 m. � N"Itll"!C°MMth Me PbriCa ..ad�wAflNwYi1 WEOEFSR Oa...F...,vino �� c RA:642A,RA1646,RA16B0. (er On,H6),ttE. M04wo. 16-0712.07 T � OR7M<S SIDdoM1Y D6lflh.:AtB ap°RrwsExn,e: RP1]60,RP1/60,RP1618, RR='-,", DA4e•RP1660,RD1160, 6 REINFORCING PLATE �`Ptr."°" 'znsn"21 �51TIE-DOWN CLIP LAYOUT R 46•RMIA20M u �' RAAwzD4a.RANAzom, i 6• r•o• SECTIow By b S 1 N.T.S. LLac ccM6R5U DIAV Pl74&,RPAJN760. MIanLL- @511PNP2Na4 RPNP20ea. SUPPORTW 61r DrMERaI I � I y 4 E 1 1 I (