EL-18-785 Permit.NO. EL-3-18-785
Miami Shores Village Permit Type:Electrical-Residential
re d 10050 N.E.2nd Avenue NWa Work Classification:Service Change
Miami Shores, FL 33138-0000 'Pr,
Phone: (305)795-2204 PennifStatus:APPROVED
FCORLDA
Issue Date:411112018 Expiration: 10/08/2018
Project Address Parcel Number Applicant
10804 NW 2 Avenue 1121360020140
Miami Shores, FL 33168- Block: Lot: ANGELA M HENAO
Owner Information Address Phone Cell
ANGELA M HENAO 10804 NW 2 Avenue (305)793-2495
MIAMI SHORES FL 33168-
10804 NW 2 Avenue
MIAMI SHORES FL 33168-
C,ontractor(s)
3168-C,ontractor(s) Phone Cell Phone
Valuation: $ 1,000.00
MITCH JOSEPH INC (954)655-7911
Total Sq Feet: 0
Type of Work:work with-CONVERSION FROM OVERHEA Available Inspections:
Additional Info:work with-CONVERSION FROM OVERHEA Inspection Type:
Classification:Residential
Review Electrical
Scanning: 1 Review Electrical
a
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $0.60
DBPR Fee Invoice# EL-3-18-66931
$2.25 04/11/2018 Credit Card $ 108.85 $50.00
DCA Fee $2.00
Education Surcharge $0.20 03/27/2018 Credit Card $50.00 $0.00
Permit Fee-Additions/Alterations $150.00
Scanning Fee $3.00
Technology Fee $0.80
Total: $158.85
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertairiing thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonin Futhermore, I thorize the above-named contractor to do the work stated.
A1C J �n April 11, 2018
Authorized Si nature:Ow er / Applicant / Contractor / Agent Date
Building Department Copy
April 11, 2018 1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
{
Inspection Number: INSP-301684 Permit Number: EL-3-18-785
Scheduled Inspection Date: May 03, 2018 Permit Type: Electrical - Residential
Inspector: Devaney, Michael Inspection Type: Final
Owner: HENAO,ANGELA M Work Classification: Service Change
Job Address: 10804 NW 2 Avenue
Miami Shores, FL 33168- Phone Number (305)793-2495
Parcel Number 1121360020140
Project: <NONE>
I
Contractor: MITCH JOSEPH INC Phone: (954)655-7911
Building Department Comments
work with-CONVERSION FROM OVERHEAD TO Infractio Passed Comments
UNDERGROUND INSPECTOR COMMENTS False
i o
21/ Inspector Comments
CREATED AS REINSPECTION FOR INSP-301426. F P L notified of work
Passed r with approval.
Failed
l
Correction
Needed ❑ /"t
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
i
May 02,2018 For Inspections please call: (305)762-4949 Page 13 of 35
i t _
1 I _F7C FXVED
Miami Shores Village
g MAR 2 7 18
Building Department
�� _ � ,_
10050 N.E.2nd Avenue, Miami Shores,Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972
! \ INSPECTION LINE PHONE NUMBER:(305)762-4949 6
FBC 201-7
BUILDING Master Permit No.
PERMIT APPLICATION Sub Permit No.
❑BUILDING Q ELECTRIC ❑ ROOFING ❑ REVISION EXTENSION ❑RENEWAL
PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS [:] CHANGE OF [:] CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 10804 NW 2 AVE
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: 11-2136-002-0140 Is the Building Historically Designated:Yes NO NO
'Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name(Fee Simple Titleholder):ANGELA HENAO Phone#:
Address: 10804 NW 2 AVE
'City: MIAMI SHORES State: FL Zip: 33168
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR:Company Name: MITCH JOSEPH INC Phone#: 954-655-7911
Address: 1101 NW 95 AVE
City: PLANTATION State: FL Zip: 33322
Qualifier Name: MITCHELLE JOSEPH Phone#: 786-251-2978
State Certification or Registration#: EC13002559 Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ 1000 Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: WORK-WITH CprJ!--12 S;VyJ f4D-k VUL`iZHQftb
Specify color of color thru tile:
Submittal Fee$ QJ Permit Fee$ 1-4--®r49!3 CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$ Ob - J C
(Revised02/24/2014) i
Bonding Company's Name(if applicable)
Bonding Company's Address _
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
I commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
I construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
'FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
r
!"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of � N ,20 /9 by ,, 6 day of 14 20 IX by
fT1�fiZLri who is personally known to ►"17 ltu_Z Cc�VSt17 ,who is personally known to
me or who has produced as me or who has produced as
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
Print: Ci4-a-IC70sf"t Print:
Seal: ;: CHRISTOPHER COX Seal: ;ion!""L4�: CHRISTOPHER COX
MY COMMISSION#GG011522 MY COMMISSION#GG011522
E>kPIRES July 13.2020 "'�','Zn Orr EAPIRES July 13,2020
FI rid No S.m.oom (4D7)398 0153 Florldallote Servioe.com
********* ***s****************** * ************************«***************
APPROVED BY lJ��-l� Plans Examiner Zoning
I
Structural Review Clerk
(Revised02/24/2014)
I
I � EL a=S RECEIVED
Nllami Shores Village
BY MAR 6 �$
DAZL-
f`�� F? f"R C'• �: APFRC`•VED
1
ZI)NING DEP
_()a_DEPT ,
`.�'•� �t 1p QCT TO n�ON1PLIANCE V`(I FH ALL FEDERAL
�� ,,.�r. ,_„• ', iy^,�•� f-C nID R,-CU! AT—) �..s .
qv,
ELECTRICAL LOAD CALCULATIONS
EXISTING ITEM
1/0 THWN 1-1/4'
O FT 1,635
GENERAL LIGHTING(3W/SF) 4,905
MALL APPLIANCES 4,500 pQHER COX
O NEMA 3R 10KA/C NEMA 3R OODRANGE 18000 #GG011522
M 2 I EXISTING
200 ICROWAVE 1,200 '� �)y 13,2020
NATER HEATER 11,080 � a{i{�`�� CtidallotarySirvic•�”
PANEL 3ATH REC.GFI 4,500 (4 7;388-0153
EXISTING 'A EFRIGERATOR 1,500
LOW RYER 5,000
VOLT 200A ASHER 1,500
EXISTING
DISHWASHER 1,500 ••••
1/OTHWN LOCATED DISPOSAL 800 • •
OUTSIDE XT.LIGHT AND RECEPT, 400
HOUSE • • •f0i 00!00•
• XHAUST FAN 600 • • • 0
•
1-1/4' •
3#1 THWN 0.00•• •foe •0f00i
ONNECTED LOAD(LESS A/C) 50,085 •
IRST 10 KW(9100% 10,000 •• ••• • � •
••000•
AL.(4140% 16,034 •ii• f0•a . •
#6CU
C OR HTG @ 100% 11,040 ••00!• • •
�1 •10• )0f0f
DEMAND LOAD 37,074 • f
MPS(9 240/12OV. 1 PH. 154 0 0.0 0• to:**
•0 0 0•
• •
SPACED 6'BOND TO A 3/4'COPPER WATER
CONNECT TO TWO 5/8'x10'GROUNDING RODS •REAKER SIZE 200 •0 00 •f • ••••••
UNDERGROUND TO FPL PIPE STUB-OUT AT METER LOCATION& 0
ENCASED GROUND SEE DETAIL. 1JEUTRALLOAD PANEL'A •••••• i •
•
IGHT.WASHER,SM APPL. 10,905 • 0 • a • •J••••
KW(ID 100% 3000 010009
• s f • •
ALANCE @ 35% 2,767 • • • :6000:
•
RANGE @70% 8,400 •• • 0•0 0•0
ELECTRIC RISER DIAGRAM ATHROOM(GFI) 4500 •• •
20 V APPLIANCES 1500
SCALE:N.T.S. OTAL NEUTRAL W. 31,072
EUTRAL AMPS(N.W./240) 129