RF-18-499 (2) Inspection Worksheet
Miami,Shores Village
10030 N.E.2nd Avenue Miami Shores,FL
Phone:(305)796-2204 Fax: (306)766-8972
Inspection Number: FISP-301101 Permit Number: RF-2-18499
Scheduled Inspection Date:April 10,2018 Permit Type: Roof
Inspector: Naranjo,Ismael
Inspection Type: Final Roof
Owner. RICH,REF1E Work Classification: T ie/Fiat
Job Address.105516 NE 3 Avenue
Miami Shares,FI-.33138-2007 Phone Number
Project. <Nt,3NE> Parcel Number 1122310130390
Contractor: PERKINS ROOFING CORPORATION Phone.,(305)687.6521
Y� Y IYYYYYYYI�41�.�
Building Department Comments
RE-ROOF TILE AND FLAT TO INCLUDE GUEST HOUSE tMractlo Passed Comments
INSPECTOR COMMENTS False
1. Inspection was denied by Mr.Alvarez because the low .
slope roof system was concealed.The deck is exposed from
the underside. Based on the pictures provided by the
F qualifier Mr. Perkins the undedayment was not properly nail.
The contractor needs to expose the entire system,and
request the required inspections. FBC 110.1
tear Comments
Passed CREATED AS REINSPECTION FOR INSP-301616,CREATED AS
REINSPECTION FOR INSP 3003 0. CREATED AS REINSPECTION FOR
Eli (NSP-3001 52. CREATED AS REINSPECTION FOR,INSP.298183.
3/2Q2018
Failed NO LADDER l PERMIT POSTED
2:1M
03•303 2018
Correction 1. Screws for counter flashing on walls including the chimney should be 1Z"
Needed D Maximum and should be properly seat
2. Deed to fix the the underlayment at the bottom of the valley on the Nutt
i
sedon of the roof.
Re-Inspection � 41812018 NO LADDER/PERMIT POSTED AT B
Fee
No Additional Inspections can be scheduled until
re4nspecdion fee is paid
r
i
April 09,2018 For Inspections please call:(305)762-4949 Page 16 of zs
F r
PA
43
-` ' 'a`�.a�. .:..., ... ..•r... 3 .r�' '��'i?� `�^9•' t�$+a- „y«,w-o 7y'*y g, ? '§-. � g�sly �'a�,i ['F� l�ajy€r J„9 ?+
(
Peftt,No. RF-2-18-499
Miami Shores Village Petmit Type:Roof
10050 N.E.2nd Avenue NE
Pen �mt Work Cfassificatfon:Tile/Flat
Miami Shores,FL 33138-0000
Phone: (305)795-2204 Permit Status:APPROVED
lNiE9 M
oR1vA
Issue Date-2/27/201$ Expiration: 08/26/2018
Project Address Parcel Number Applicant
10515 NE 3 Avenue 1122310130380
RENE RICH
Miami Shores, FL 33138-2007 Block: Lot:
Owner Information Address Phone Cell
RENE RICH 10515 NE 3 Avenue
i MIAMI SHORES FL 33138-2007
10515 NE'3 Avenue
MIAMI SHORES FL 33138-2007
Contractor(s), Phone Cell Phone $ 24,130.00
Valuation:
PERKINS ROOFING CORPORATION (305)687-6521 (786)277-8486
--� -��--• Total Sq Feet: 2485
Type of Work:Re Roof Available Inspections:
Additional Info:RE-ROOF TILE AND FLAT TO INCLUDE GU Inspection Type:
Classification:Residential'
Up Lift Report
Scanning:3` Tin Cap
Final Roof
Tile In Progress
Roof in Progress
Renailing Affidavit
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00
Invoice# RF-2-18-66591
CCF $15.00
DBPR Fee $4.50 02/27/2018 Check#:3197 $856.50 $0.00
DCA Fee $3.00 Bond#:3673
Education Surcharge $5.00
Permit Fee-New Roof $300.00
Scanning Fee $9.00
Technology Fee $20.00
Total: $856.50
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constructio and joning. Futhermore,I authorize the above-named contractor to do the work stated.
L,,— February 27, 2018
Authorized Signature:Owner / Applicant / ontractor / Agent Date
Building Department Copy t
February 27, 2018 1
ewe� c � �a ,�Mo�1�
4
f
OR
Esq Miami shores. e V ilia
� 9
...� .....� Budding Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
�lORiDp' Tel: (305)795.2204
Faz: (305)756.8972
RE: Permitol F• y t
DATE:� �S
INSPECTION AFFIDAVIT
P_C n Cy itl I n f Prc�'
,, licensed as a (nContracto /Engineer Architect,
(Print name and circle License Type) FS 468 Building Inspector
i
License#: C CG �IA 7 ?4
On or aboutI did personally inspect the roof deck nailing
(Date&time) J)
work at ��-S/,S /U 3rd '40c, Nlo , S� ores
(Complete Job Site Address)
Based upon that examination I have determined.the installation was done according to the Hurricane Mitigation Retrofit
Manual (Based on 553.844 F.S)
dei
Signature
State of Florida
County of Dade:
The undersigned, being the first duly sworn,deposes and says that he/she is the contractor for the above property t
mentioned.
Sworn to and subscribed before me this c/
-lI— day of b
Notary Public, Sate of Florida at Lorge -*Vpf" Notary Public State of Florida
Rolando Cruz Jr
My Commission GG 128538
a w� Expires 07/20/2021
d
t 'General,Building,Residential,or Roofing Contractors or any individual certified under 468 F.S.to make such an inspection.Include photographs of each'plane of the roof with
permit#and address#clearly shown marked on the deck for eachrinspection
t oo,aoo.+�..nr�nnn+nFn�nn�o
a
Miami Shores Village - D
Building Department
e A27, 2101119110050 N.E.2nd Avenue,Miami Shores,Florida 33138 4B .
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949
4
FBC 201-4
BUILDING Master Permit No.
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION [-] SHOP
i CONTRACTOR DRAWINGS
JOB ADDRESS: . � �✓ Q., 3 rcl A-V-e—
City: Miami Shores County: Miami Dade Zip: 3
Folio/Parcel#: 223 —o l 3 "-C) 38c�, Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): peiN '
\ tr k Phone#:
Address: /os/ .r AjE r-4- /TVe•
City: Mt 4'm i Shote State: �L Zip:
Tenant/Lessee Name: Phone#: 30.r .36 7�
Email: r e h C c l A M0 /01% p C dl•1
CONTRACTOR:Company Name: At- �oo� CDC p. Phone#:
Address:_ � �W L5_21--
City: mt cA My State: �"L. Zip: 2?16
Qualifier Name:_ 'L 20,n CUIC N-\S &r g l"A& Phone#: .305- 617 - 4:411
State Certification or'Registration#: C cc oq;'- 46 Certificate of Competency M
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
E ' \
Value of Work for this Permit:$ c�'4 3 C7 Square/Linear Footage of Work: �"
Type of Work: ❑ Addition ❑ Alteration El New ❑ Repair/Replace
❑ Demolition
Description of Work: e �60� T��� l _ ITC) yNC.�k-tao6�\_, ��
Specify color of color thru tile: C a t—
Submittal Fee$ W Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee_$(
Structural Reviews$ Bond$ W
TOTAL FEE NOW DUE$
(Revised02/24/2014)
• I
Bonding Company's Name(if applicable)
Bonding Company's Address _
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
a
Application is hereby made to obtain a permit to do the work_ and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of:all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
'
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU` INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500,�the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencementr must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will no rov an reinspection fee will be charged.
Signature Signature
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
I day of 20 i r by -3- day of Feb ,20 19 by
who is personally known to ,who is personally known to
%
i.
me or who has produced ..l—Jere t,CCL4 t, ryas me or who has produced as
identification and who did take an oath. I),-110; identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
Print: C�L('LJ�� Print: r
1 Seal: Notary Public Stft of Fbriae Seal:
*` Rolando Cruz Jr Notary Public State on Flo]-
Expires
• Rolando Cruz Jr
c My Commission GG 128534 My commission GG 1265
sr w 07lM021
Expires 07/202011
APPROVED BY ` Plans Examiner Zoning
;
Structural Review Clerk
(Revised02/24/2014)
1/23/26118 Property Search Application-Miami-Dade County j
r
1 ,$
When buying real estate property,you should not assume that property taxes will remain the same.Whenever there is a change in ownership,the assessed value of the property may reset to full
IMPORTANT market value,which could result in higher property taxes.Please use our Tax Estimator to approximate your new properly taxes.
MESSAGE
The Property Appraiser does not send tax bills and does not set or collect taxes.Please visit the Tax Collector's website directly for additional information.
I
p Address Owner Name Folio
_1
SEARCH:
10515 ne 3 ave Suite D
I..... ..................... ... ..... _. ._ _........_.._.....__ ......._. .. ...,........... ......... _ __._.. --- .. ___..._.�._
I PROPERTY INFORMATION-
i
Folio:11-2231-013-0380 ;-
}'
Sub-Division: p
s PASADENA PARK 1ST ADDN
I
i
Property Address
10515 NE 3AVE
Miami Shores,FL 33138-2007 ,
Owner
RENE RICH
MailingAddress '
10515 NE3AVE }
MIAMI SHORES,FL 33138-2007
PA Primary Zone -
'1000 SGL FAMILY-2101-2300 SO a
r {
Primary Land Use
0101 RESIDENTIAL-SINGLE FAMILY:1 UNIT
. 7
Beds/Baths/Half 4/3/0
Floors - 1 •
r i
I
Living Units 1
Actual Area
Living Area
>Adjusted Area' 2,119 Sq.Ft
? Lot Size 14,375 Sq.Ft '
Year Built 1940
Zoom Map View :t Layers
' 1
https://www.miamidade.gov/propertysearch/#/ 1/3
} F V_
1/23/7618 Property Search Application-Miami-Dade County 1
.. I
i
I
I
t
i
2017 Aerial Photography
Featured Online Tools
Comparable Sales Glossary
Non-Ad Valorem Assessments PA Additional Online Tools
Property Record Cards Property Search Help
{
Property Taxes Report Discrepancies
Report Homestead Fraud Tax Comparison
Tax Estimator TRIM Notice t
Value Adjustment Board
i
ASSESSMENT INFORMATION
$ i
Year 2017 2016 I 2015
Land Value $359,519 $300,581 $240,465 1
g F
i Building Value $149,730 $149,862 $151,091 I
e Extra Feature Value $23,585 $23,743 $17,596
....._......_.__..___.___._--.t.__.-___._.__ ��__,_._._.__.__...._ ..................
....._......_.....__.._...._.__......._.,.____._.
Market Value $532,834 $474,186 $409,152
Assessed Value $350,582 $343,372 f $340,986
t
TAXABLE VALUE INFORMATION
y. 2617 2616 f 2615;
R COUNTY
t Exam tion Value
P $50,000 $50,000 $50,000
Taxable Value $300,582 $293,372 $2----
I SCHOOL BOARD ....,..... .. .....,.....,.., ,_........_..._.._-_-_-t
0 Exemptlon Value $25,000 $25,000 1 $25,000 s
4
.Taxable Value
$325,582 $318,372 $315,986
I CITY.
Exemption Value $50,000 $50,000 $50,000,
'd Taxable Value $300,582 $293,372 $290,986
REGIONAL .......... ........... ........_.........._..__ �..
c_ .,.__....._... __.__._ ._....._._._.�---___._..__ ___.__._....._. _ ........._ ........_..,..,....
Exemption Value $50,000 $50,000 { $50,000
i
r efps://www.miamidade.gov/propertysearch/#/ 2/3
r
1/23/7418 Property Search Application-Miami-Dade County
Taxable Value $300,582 1293.372 $290,986
—-------- -
.............–
BENEFITS INFORMATION
Benefit Type 2017 2016 2015
Save Our Homes Cap Assessment Reduction $182,252 $130,814 $68,166
• Homestead Exemption $25,000 $25,000 $25.000
Second Homestead Exemption $25,000 $25,000 $25,000
Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Board,City,Regional).
FULL LEGAL DESCRIPTION
FIRST ADD TO PASADENA PARK
PB 6-82
LOTS 15-16&N1/2 LOT 17 BLK 12
LOT SIZE 125.000 X 115
OR 20616-3199 06/2002 1
•SALES INFORMATION
Previous Sale I Price OR Book-Page Qualification Description
06/01/2002 $375,000 20616-3199 Sales which are qualified
03/0112002 $250,000 20277-4203 Sales which are qualified
03/01/1992 $150,000 15449-1175 Sales which are qualified
08/0111979 $76,000 10486-1644 Sales which are qualified
05/01/1976 $51,000. 00000-00000 Sales which are qualified
Fd r more information about the Department of Revenue's Sales Qualification Codes.
2017 2016 2015
. ... ...... ......
LAND INFORMATION
i Land Use Muni Zone PA Zone Unit Type Units Calc value
GENERAL R-17.5,R-18.5 1000-SGL FAMILY-2101-2300 So Front Ft. 125.00 $359,519
BUILDING INFORMATION
Building Number Sub Area Year Built Actual Sq.Ft. Living Sq.Ft Adj Sq.Ft. Cale Value
1 1 1940 1,439 $100,154
1 2 1948 452 $31,459
1 3 1983 228 $18,117
...........
EXTRA FEATURES
Description Year Built Units Calc Value
Patio-Terrazzo,Pebble
1984 410 $1,839
Patio-.Wood Dock 1984 280 $1,372
Pool 6'res AVG 3.8'dpth,plain feat 250-649 sf 1984 1 $17,250
Wall-CBS unreinforced 1940 1.420 13,124
ADDITIONAL INFORMATION
The information listed below is not derived from the Property Appraiser's Office records.It is provided for convenience and is derived from other government agencies.
https://www.miamidade.gov/propertysearch/#"`/ 3/3
i
,SeoREs L�! Miami Shores Village
t
note Department
10050 N.E.2nd Avenue
11D Miami Shores, Florida 33138
I Tel: (305) 795.2204
Fax: (305) 756.8972
t
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S. I
To: Miami Shores Village Building Department Date: ,7.©
1.0
10050 NE 2nd Ave
Miami Shores, FI 331338
Re:x' Owner's Name: A en a cl�
Property Address: s/ j- /U 3 Ue
Roofing Permit Number: '
Dear Building Official:
certify that I am not required to retrofit the roof to wall connections of my
building because:
/The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please,attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 4 e 'tion of South a Building Code (1994 SFBC)
x
Signature Print Name
Statc of Florida
f county of Dade
The,undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property m tioned.
,.wr.)rn to and subscribed before me this - day of
", W 5 pcu�
t µY ,1F�5 � U
7.
"lotary Public, Sate of Florida at Large '"%r -g �,y
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,,and the building was not constructed with FBC nor a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Walt connection Hurricane Mitigation.
revir>vd on 5/21/2009
r
Perkins Roofing Corporation ``d��e
575 NW 152 Street PERKINS r en`i-F
Miami, FL 33169-6615 US RC�C);ING
(305) 687-6521 CURL? S �O
(3051687.65'1
vp@perkinsroofing.net Ww,V.1,c;k;nsioo,;j)g,,,c,
www.perkinsroofing.net A e,4-vrj% IA&I eypy
Perk TAJ
ADDRESS ESTIMATE 2972 (1 car.!
Rene Rich
10515 NE 3rd Ave. Miami
Shores, FL. 33138 DATE 01/08/2018
SALES REP
Rolando Cruz Jr
AMOUNTACTIVITY
NEW CONCRETE TILE RE-ROOF MAIN & GUEST HOUSE (ENTEGRA
DOUBLE ROLL TILE), FLATROOFSILICONE RESTORATION
---CONCRETE TILE (MAIN HOUSE)---
Specifications of Proposed Work:
1. Obtain the roofing permit. We do all processing, you pay permit fee(s)
only.
F
2. Tear off existing roof system and dispose of debris. f
3. Replace any damaged or rotten decking wood as needed. An allotment of
100 linear feet of decking wood (total) is included at no additional charge.
Any additional decking (wood) discovered over 100 linear feet will be
replaced at our cost of.$3.00 per linear foot and invoiced. Any other wood
types possibly needed are installed and invoiced at $45. per man/hr plus the
wood cost.
***Note if plywood decking: An allotment of 2 sheets of plywood (installed) is
included at no additional charge. Any additional damaged plywood
discovered over 2 sheets, will be installed at our cost of$65. per sheet and
invoiced to you.
4. Re-nail existing decking and/or sheathing using 8d ring shank nails per
revised Florida Building Code.
5. Install one layer of ASTM 30#felt using 1-1/4 inch ring shank nails and
Miami-Dade approved tin tags.
6. Fabricate, prime, and install factory painted perimeter drip edge metal.
This metal is to be fastened every four inches using 1-1/4 inch ring shank
nails. 1
7. Install ASTM Certified roof tile underlayment.
8. Install new 16 inch 26 gage galvanized metal in all roof valleys.
9. Install standard concrete 13" DOUBLE ROLL TILE. Install tiles set in 3M
Polyfoam tile adhesive. Selection of a more expensive the will increase the
quoted pricing..
FL State Certified CCC042786
ACTIVITY
AMOUNT
---CONCRETE TILE (MAIN HOUSE)---
Specifications of Proposed Work:
10. Install 26 gage galvanized hip and ridge anchor metal.
11. Install new hip and ridge tiles and point them up with mortar, your choice
of color.
12. Replace all plumbing vent flashings.
13. Replace "all purpose" ventilators with new.
14. Clean up and haul away debris daily.,_
---CONCRETE TILE(GUEST HOUSE)---
Specifications of Proposed Work:
1. Obtain the roofing permit. We do all processing, you pay permit fee(s)
only.
2. Tear off existing roof.system and dispose of debris.
3. Replace any damaged or rotten decking wood as needed. An allotment of
100 linear feet of decking wood (total) is included at no additional charge.
Any additional decking (wood) discovered over 100 linear feet will.be
replaced at our cost of $3.00 per linear foot and invoiced. Any other wood
types possibly needed are installed and invoiced at $45. per man/hr plus the
wood cost.
***Note if plywood decking: An allotment of 2 sheets of plywood (installed) is
included at no additional charge. Any additional damaged plywood
discovered over 2 sheets, will be installed at our cost of $65. per sheet and
invoiced to you.
4. Re-nail existing decking and /or sheathing using 8d ring shank nails per
revised Florida Building Code.
5. Install one layer of ASTM 30#-felt using 1-1/4 inch ring shank nails and
Miami-Dade approved tin tags.
6. Fabricate, prime, and install factory Painted perimeter drip edge metal.
This metal is to be fastened every four inches using 1-1/4 inch ring shank
{ nails.
7. Install ASTM Certified roof tile underlayment.
8. Install new 16 inch 26 gage galvanized metal in all roof valleys.
9. Install standard concrete 13" DOUBLE ROLL TILE. Install tiles set in 311M
Polyfoam tile adhesive. Selection of a more expensive tile will increase the
_,_,__quoted
---CONCRETE TILE (GUEST HOUSE)---
Specifications of Proposed Work:
10. Install 26 gage galvanized hip and ridge anchor metal.
11. Install new hip and ridge tiles and point them up with mortar, your choice
of color.
12. Replace all plumbing vent flashings.
13. Replace "all purpose" ventilators with new.
14. Clean up and haul_away debris daily_
---WARRANTY ( CONCRETE TILE MAIN HOUSE AND GUEST HOUSE)---
Perkins Roofing Limited Warranty of TEN year(s) upon final payment and
signed warranty certificate
FL State Certified CCC042786
ACTIVITY
AMOUNT
---GAF UNISIL SILICONE FLUID-APPLIED ROOFING SYSTEM---
Specifications of Proposed Work:
1. Remove debris and pressure clean the flat roof decks, allow to dry..
2. Apply GAF FoundationCoat throughout the roof decks thoroughly
repairing fissures, voids and imperfections and allow to dry.
3. Apply a base coat of GAF Unisil High Solids two-part primer.
4. Generously apply two saturation coats of GAF Unisil silicone FinishCoat
forming a monolithic seal, allow to dry.
5. Seal all flashings and penetrations with GAF Unisil.
6. Clean up and haul away debris daily.
---WARRANTY (FLAT ROOF COATING)---
Perkins Roofing Limited Warranty of FIVE years upon final payment'and
signed Perkins.Roofing Limited Warranty certificate.
GAF provides a TEN year Limited Warranty on Materials
(OPTIONAL) GAF provides a TEN year NDL Labor and Material Warranty
_or an additional fee (Moisture Surveyor Certified Pull Test Required)
---ADDITIONAL INFORMATION---
1. All roof work done in accordance with the high velocity hurricane zone
section of the-Florida Building Code.
2. Permitting and processing is done by Perkins Roofing Corp. for no
additional fee.
3. Permit and Engineering fees will be an additional charge to the price
1 __given below__.___._. .._.___
__130_
. ..24, .00-M..T-_
Includes all service dates, skilled techs, supplies and materials, waste
service fee, taxes and insurance.
---ITEMIZATION---
Double Roll Tile Re-Roof(MAIN HOUSE): $13,850.00
Double Roll Tile Re-Roof (GUEST HOUSE): $7,500.00
Flat Roof Restoration: $2,780.00
---TERMS---
5% upon acceptance
30% upon permitting and mobilization
30% upon installation of roofing underlayment and delivery of shingles
Remaining net balance upon completion
ID
---FLORA HOMEOWNERS' CONSTRUCTION RECOVERY FUND---___,_
Payment, up to a limited amount, may be available from the Florida
Homeowners' Construction Recovery Fund if you lose money on a project
performed under contract, where the loss results from specified violations of
Florida Law by a licensed contractor. For information about the recovery
fund and filing a claim, contact the Florida Construction Industry Licensing
Board at the following telephone number and address:
1940 North Monroe gt.
Tallahassee, FL 32399-0783
Telephone: 850-487-1395
f_w
Website: ww.mY .loridalien
cse.com
_ _ __._ . ._..___________-_._.._.__ _._..._.____.__
i
FL State Certified CCC042786
ACTIVITY
AMOUNT
---CONTRACT PROVISIONS---
1. LIABILITY: It is agreed that Perkins Roofing Corporation is liability
insured as per Florida Law, but will not be held responsible for construction
effects such as but not limited to dust, dirt, noise, asphalt, landscape, walks,
drives, sudden rainstorms or any accident beyond our control.
2. WARRANTY: Any warranty shall apply to specifications only and does
not cover additional damage to property.
3. Damage to roof caused by obvious circumstances such as but not limited
to trees, footwear, termites, mold, additional work done by others, etc. is also
not warranted.
4. EXISTING STRUCTURE: Perkins Roofing Corporation can not be held
liable for undetectable deficiencies within the existing structure/deck
underneath the roofing system.
5. DEMOBILIZATION: If asked to demobilize by the owner, property
manager or GC for whatever reason, all Perkins.Roofing Corp. expenses,
including profit and overhead will be covered up to the point of ,
demobilization.
6. ADDITIONAL TERMS AGREEMENT: In the event payment is not made
as agreed in Terms, all fees incurred in collection are to be paid by owner or
signer.
7. LATE FEES: If payment surpasses 30 days overdue, a late fee of 5% of
the total amount due will be charged in addition to the remaining total .,
amount due. The 5% late fee will be continuously applied every 30 days
overdue unless otherwise specified within the contract.
8. LIEN RIGHTS: If payment has not been received once 45 days overdue,
Perkins Roofing, Corp. has the right to process a claim of lien unless
otherwise specified within the contract.
9. WRITTEN NOTICE: Florida law states written notice must be delivered E
to Perkins Roofing Corp. regarding any potential defects and Perkins
Roofing must be given the opportunity to correct such defects 60 days prior
attempting any legal action.
10. ATTORNEY FEES: In the event of a legal dispute, the defeated party
will pay reasonable attorney fees and travel expenses related to a legal i
dispute.
11. CREDIT CARDS: Payment with credit card will result in a 3% increase
in the total amount due (all major credit cards are accepted.
12. FINANCING: Perkins Roofing Corporation may assist in providing ,
clients with a third party financing institution in relation to roofing projects.
Perkins Roofing is not held directly responsible for making payments or
,, _ "arrangingjinancing terms and interest rates.
--CONTRACT
PROVISIONS---
13.
ROVISIONS--13. CASH BACK FOR REVIEWS: If you provide us a positive review on
Google, Facebook and_Yelp, Perkins Roofing Corp. will discount your total
bill $25. `
14. NAMED STORM PRICING: Potential named storm threats may affect
material pricing and availability. In the instance of a Named Storm landing in
South Florida, Perkins Roofing must be compensated regarding pricing
increases and scheduling issues due to material delays or unworkable
weather.
15. PRICE QUOTE: This estimate will be automatically withdrawn if not
accepted within ninety (90) days. .
16. The above prices, specifications and conditions are satisfactory and
Thank you for your business.
FL State Certified CCC042786
Check out our portfolio at
www.perkinsroofing.net
TOTAL00
A
Accepted By Accepted Date
3
2
1
1
9
F
1
FL State Certified CCC042786 t
I
Florida Building Code 6th Edition (2017)
High-Velocity •ne Uniform Permit Application
• n A (G2negal Informatio
Mader Pawed No. ♦iProcess No.
r r •
job Address. C♦
- • • • -
■ Mechanically Fastened Tile / �dAdheslvs Set Tile
■ ■ ■ Wood ShInihiakes
Shingles
Are there
■ i Gas Vent Stardft?
Yes■
ROOFTYPE ■ bGXU
■ ■ Recovering ■ Repair ■ Maintenance
ROOF SYSTEM INFORMATION
SlopeLow , Slo"d Roe Area(SF) Total(SF)
gog
Section _ (Roof Plan)
Sketch ' • •f Plan:-Illustrate all levels and sections, roof drains, scuppers,
sectionsscuppers and overflow drains. Include dimensions of
locationIderift dimensions of elevated pressure zorm and
t\iCC■SEC\CCS'R�■iiCCtCrCirr��lCC��itw�CA<frAr��iCC��CC"■!Cr�CfC"CC�CM�C��Cit
_ ir!!i�®■!■■!■M■iwt ■■lirr■■liiol■i■■■■■r■ rr■i■ti■■flit■■■i#■/t��■iliitorrr/■
I;. if.. ..:-;.`I#iiii■ ■lC!■ ■r■li■■lrlitllrlt C�llllrr!■ ■tr■t/triwi■ t■!■■■■�■#!,!l■rlrttMal
t'■CMC M' %'rl1��C :nual: 11111Cin MEIN iallC€��non
al-nommin"
SCCC.rr.C...■itt�'Cif C'1llili'Cr.■7ilirilt o�ll a ■■■a ■tt!■i!l■i0 iir
• !YI•I■i!■if!■iillitl/rlrrt lr•�t■■!li/rl mpg:
!■ liilii�•••••••l#!■ ■�i ■#t!i!t■#Il!■■!�■■
f i■■iifi■■■■■iii■J/rsr--�.wrrrrrwr■■'rt p■■�■lltt!■llonIll Ctllill■■l!!l!#r!!■
I1■#tititlllo■■■■■■w t l�%fir\#■!!#■ir it►'#lwil■■■iw7iitl t■t�■lt■adult■■wo■#!■r
r1r.■ltnt■rlttrrt■�
•.��--�.�.�!•fH\!�`!l■CS'�il#�t�■rr■iIfro■#■ttr!i!■!ti rK■ctirilli.-■rlr!iriol�linJt■tr■!■ C �W\r
Rini? ■oil61lrll lraa ■ilr■�1■11rCHt: ■■rO /■■i1cn!i#CtIIIrieI►!w
Lmb;, orlot#olfir■ t■l =- rltltTTr•■samii=ao.rrw"Rama i ■li!■ ■■ ■ --- ri :i .-r --■axS ■ !: � ■■i#ii��tf��\■i !w ■ ■w■ 1:7■rll ■i�t!r !! t ■ �➢I
as
MENEM
•
fitt�]tir■Dii■■ ■I.'.Ji■ i■l■■CitCrilrG9i#r■r■irlt■■oi■illi!■■iiEnumon! All at11Ca
.!#.. wo■A■O■wsE_ lo/iiiitA�� I■ iiifdl■!■ ■wllilri#lilliiii! ■t■iiri•iVj9 irllS� •
rrrr■r C•Oi■Ilr ■tillC Mtllr!`■ttlll ■ it ■■■Crlp frt.�. ilrl•7
i�r■Nit■ilrC/�i�toi■ ■iflowGGrCriYlolir�ri,�rtlCE�lllr■Coll■rClClr�i■liLliG;•L1,1]!1 rl ■
f oil ■ ■.■tot ■■■■
PUSH:! Bill Iiia- slum
r! ■ ■ , ■tltr l 7.1r loss r1no "■:"tTi 1 all
rr ■ �ir>.il■!■ri■ri� r►ltirCl['r...�•!-�i�tlw■ ■!■�I'r�'r ■i:r rCr•1l'rrltrrrr �tIr,�l� l riF� _
�CECEC ': ifril'r inx"swC:C:::C: EEE;�6:o : E�;' C „C��E01 a raC.1'P l
i■ ■ 'ltCr�rliwrlt�rrrrrl i■rt
ir'r�'lrC CE iaimanual r'tliiC'CCCCCi'tCE'ir'-"a�'�ur',pit'�o�1'iCiC'i11 ' C'tii■■'C�i'iiCEilllgC`i -r'inum Eii
wit!■ Mlrrli:71irlwuiiwiCllliiCllil■il■r t ■■rrluirSir■ ■■
LLlNLilL7rlt]■❑7■7�■■■■■lwirk■r'r■rlliarllrislCii#rlrininn a ii■lninz\C-i■!! ■�
ftLlG■GiQrOw�iaLl�i�i■■lruw rrr>mill■rrillorirtiloo■iinowtoEt�ri■ll\. ■tliwEM
ilL WL EM IL---■r■r■wwltaiMWlrtralrr■l!■tnli�ti��lw�� litw r rr�\t^ll■■t
i"'C�1►�C°CaC°��i'�'i�'''r'■C��_-:'-i'Ca�i�iCC'Ci CCCCCr'�'iiGiiG' !CCC Cf'ii'i`ti CifiCC'lii
1:::::::::�►'.�.C::.a':Ctf�'Ci'CCCCC'ECC"Cl ECCii ECC 'Ci U-i■�Clirl ll
■/ 1 In' ■■i■ Ir
::':C�C��C�CG�C�CCWHEN wassulllC i.CC..Ma ECC.CE.at .::•rC
l ■Arlt!rl■!C■iliirrtr�olwltwA\Nltt.!fi r#girl••, ��
■i�to iC�ilECl��1■tri■iw� _,r■It ,■I.1�9[n] a■�'1�!■l■w.■■ww■iin In �!'�.7■■■ 7itlil ll il■
l! V;7 t■ ]lt7lii [Ir!{f1ilil•1•ilwi:l l,r]rl ■circ! ■tiii■ `t N■ o �7tGr 11\G•rrl�
r l'ri C�Ju�iH%i7tC�i�C!►w�l1l�,�liiMller� '7C:��ra�A'!�'a a ■ C�rs�til1fGifW.) ila.L;mMasl■
f■:f�dit�7� ■7t#t�t7irl[I■■■Ilrtwilfiitllt!►/illiioCi/�/ittl�� lirEtf �li!'i������
ii�r•++'�I '� aCii`►"i��■ , ii'■li� '�rCCiCCitC■CCCC�"CE SCC=�� G � C;i
i � w■ � ilfitot~#r I .7 I/irlll■ l!t■ l oM/ ■ wt
f r! ■ lllii.■ ■liiirrr#!it/ r�ulirR lrl]■ir##R i ■ ■ti t ■ ■!■tl :Alt. ■'!
i■##■#! ■i ■i■#tt!/:+:+7tlf�\■ii1Cl#til# ■i ��ii■ t! M■itll9llrt�lii�'rt■
1■o■rt■
Mimi 111i flat /lir ■■ C■ltrll'7littiw! tz
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form
Section C (Low Sloped Roof System)
Fill in Specific Roof Assembly Components Fastener Spacing for AnchodBase Sheet
and Identify Manufacturer Attachment
(if a component Is not used,Identityas'NAJ//C 2
er.
I d 1� TIQ5> U l5 Fwd: •oc dap.#Rows.L v"oc
System Manufac�u
Perimeter. 'oc @ Lap,#Rows 'oc
NOA No.: 1 0 �w
Comer:_•oc e Lap,#Rowsoc
Design Wk l Pressures,From RAS 128 or Calculations:
Pmax1._la.��,�;��:�,a. . —)p6. d Number of Fasteners Per Insulation
y v Board
Max.Design Prsurem the Specific NOA
System: 2_ Field Perimeter
Comery
Deck t o od Illustrate Components Noted and
Type- L4 Details as Applicable:
Gaugerrhickn : 913 Woodblocdng, Gutter, Edge Termination.
/ Shipping, Flashing, Continuous Cleat, Cant
I
Slope: i!Nom• i 2 Strip, Base Flashing, Counter- Flashing,
Coping,Etc.
Anchor/OmSheet&No.of Py(s):GZ 1 F1 Y/ IOdkcaft Mean Roof Height, Parapet Haight,
_ / Height of Base Flashing, Component Material,
Material Thickness, Fastener Type, Fastener
� I f a— —4� S Spacing or Submit Manufacturers Details that
Insulation Base Layer Comply with RAS 111 and Chapter 18.
Base Insulation Size and Thickness*
Base Insulation Faster Ing Material:
�Qly �lgs}v�lc�
Top insulatio `` � �� FT. NIA
To I Size andThidmess:
. P parapet
T Insulation FastenedBonding Material: 2__� z00��4 J Height
Base Sheet(s)&No.of Py(s): a a5� ( PI-1
FT.
l /Clh QFC • N a.i lJ r In Crnates S i� Mean
R of
Ply Sh s) No.of Ply(s):� �('� G 1�b�eY { Height
s� �`( F IZ '� `t L �
Py Sheet FlBonding M�ter�L C^1 �)QS'►v b S
se 1 F .a A4.ored Q
Top 1✓� C4pPpcf
Top Ply_G ne
•gig: •� .••
. -�:. • . CU Vie re4
. .. . . . . ... .
.. ... .. . . . ..
. ••• . ••• ... .
• . . • . • •
• . . . •
. . . . . . . . . .
. .. .. . . . .. ..
. . ... • .
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Slowed Roo, f SVstem,l
Roof System Manufacturer: E/'1+Lo r oo f� 71 L e
Notice of Acceptance Number: 1 LO— O 112. 0 (p
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
P1:-39 P2: G �� P3: , c)O. -F—
Maximum Design Pressure
From the NOA Specific System)*
Method of tie attachment: I C 111 Z�
AO .r I(OO
Steep Sloped Roof SVst, tem_D,escription
Deck Type: �5/
wo 0
ype UnderhWrnent:
Roof slope: I ctb+m 2v'p zwe
nsulation:
4 ,2 14 gyp.
Ire Ba er•
Ridge Ventilation?
astener Type&Spacing: 11) r K, _ Qy �cd.p I
A P, ro�v J )Z� o.0 � el .0
dhesh►e Type �
P)
ype Cap Sheet: tv)A
.. ... . . . .. oof Covering:
p I l QHO
•. Mbarf EtabCtlii iQht:
Type&Size Drip
dge• [ 3
. ... . ... ... .
. . . . �.Ct
. . .. . . . . . . .
... . . . . ... . .
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form
Section E (,Tile Calculations)
For Moment based the systems,choose tither Method 1 or 2.Compared the values
for M,With the values from M,:If the Mt values are greater than or equal to the Mr
values,for each a m&of the roof,then the tle attachment metbod is acceptable.
Meth 1" oment Bared Tile Cak tions Per RAS 127'
s
log NOA�.3�j y
(P,- • I• I z 0. I —Mg:b�pb �1Nlii NOA 11'*
(p::—`o—!Ux)L . :-- —Mg: C NOA 11*
Method 2"Simplified 151e Calculation Per Tabk Below"
Required Moment of Resistance Ok)FYrom Table Below NOA h
M,Required Moment Resistance*
Roof Slope 1h' M' 40'
4Li2 30A 3L2 33.8 1
19`12 28A 30.1 31A 32A
26A 2LO 29A
1.112 .2 .0
*Must be used in conjunction with a no of moment based the systems endorsed by the
Broward County Board of Rules and Appeals.
For Uplift based the systems use Method 3.Compared the values for F'With the
values for X.If the F' values are greater than or equal to the F,values,for each
am-of the room then the tale attachment mood b acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 12r
(p'i:_zl: m z w:__)—W: zcoso:—= Fn: NOA F1
(P2: z 1: m z w:—_)—W: z cos o: = Fr2: NOA F'
(P3: z k = z w:-_)—W: z eds o:_= Fre: NOA F'
Where to Obtain Information
Descri on S bol Where to fmd
DesignPrasaane Pl orP2orP3 RAS 127T 1 orbyan amlysiap gmmdby PBbandonASCB
7
Mau Roof H Job Site
Roof Slw B Job Sitc
NOA
Momatt doe in NOA
•
•• •• • • • bh NOA
• •• . Reaiskm K Cslcaleted
• ` %ght noe F NOA
•• ••• •• •Regabod Upft Reese Fr Calculmd
&,=THvW.Wd W NOA
1= NOA
• ••• • ••• ••• • w-wkbh
'off to the Official�tbe tmle of
• • •• • • • • • • •
••• • • • • ••• • •
•••
• •• •• • • • •• ••
• • • ••• • •
5!�ORfs
{ F RIGA
SECTION 1524
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS '
1524.1 Scope.As it pertains to the section,it is the responsibility of roofing contractor to provide the owner with
the required roofing permit,and to explain to the owner the content of the section.The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations.Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor.The owner's
initial in the designated space indicates that the item has been explained.
2• Renailing wood decks: When replacing roofing,the existing wood roof deck may have to
be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually
concealed prior to removing the existing roof system).
4. _Exposed Ceiling: Exposed,open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance;therefore,
roofing nail penetration of the underside of the decking may not be acceptable.This provides the option of
maintaining the appearance.
5. ^_1 _Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install'overflow
s peers i he requirements of Sections R44 , R4403 and 41
e�
Owner/A nts Signature Date Contrac or Signature Date
Property Address Permit Number
Revised on 7/9/2009 LD;07/01/2015;
t
. • •• . • • • . • .
I
MAMI MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
IR 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
Entegra Roof Tile,LLC
1289 NE 9"'Ave
Okeechobee,FL 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ (in areas other than Miami-Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bella"High S"Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.05 and consists�otg4ges I thsouph 5. ••
The submitted documentation was reviewed by Ga$par J 1434 0u* 0 ;•; •
.. .
••• ;. ••' NOA No.: 16-0112.06
Mu►rtFoane courmr ••• Expiration Date:07/13/21
Approval Date:02/25/16
... •;• Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Cateeory: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This approves a roofing system using Entegra Bella"High S"concrete roof tile as manufactured in Okeechobee,
FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements,
as determined by applicable Building Code,do not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be
prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Bella"High S" Length= 16 ''/z" TAS 112 High profile,interlocking, extruded concrete roof tile
Width= 13-'/4" Type 2 equipped with two nail holes. For mechanical,mortar
Thickness= '/2" Class II or adhesive set applications.
Trim Pieces 1=varies TAS 112 Accessory trim,concrete roof pieces for use at hips,
w=varies rakes,ridges and valley terminations.
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee,FL
2.2 EVIDENCE SUBMITTED
Test Ap_ency Test Identifier Test Name/Report Date
The Center for Applied Engineering, 25-7094-(3, 6& 9) Static Uplift Testing Oct. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7120-(1 &2) Static Uplift Testing Nov. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7183-(3 &4) Static Uplift Testing Feb. 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7214-(3,4,&7) Static Uplift Testing March, 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7804-4 Static Uplift Testing Sep. 1996
Inc. TAS 102
Celotex Corporation 520111-3 Steric Uplift Testing Dec. 1998
Testing Services -0* ••• TAS 101
Celotex Corporation 520 t91;;: •; •.• :•: St Tic Uplift Testing March 1999
Testing Services TAS 101
Walker Engineering,Inc. CajcuW pns ... Aerod1gamic Multiplier March 1999
•
MIAMI•GADE COUNTY ••• • • •• • ' ' ' ' ' NOA No.: 16-0112.06
� "' Expiration Date: 07/13/21
Approval Date: 02/25/16
... ... Page 2 of 5
2.2 EVIDENCE SUBMITTED
Test Ai!ency Test Identifier Test Name/Report Date
Walker Engineering, Inc. Calculations Restoring Moment June 2007
IBA Consultants, Inc. 2421-94 ASTM C 1167 June 2006
American Test Lab of South Florida RT1210.03-15 TAS 112-95 Dec 2015
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be
required,refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Miami-Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft)
Bella "High S"Tile 10.5 1.375 1.08
Table 2: Aerodynamic Multipliers -A (ft3)
Tile A (ft3) A (ft)
Profile Batten Application Direct Deck Application
Bella "High S"Tile 0.349 0.378
Table 3: Restoring Moments due to Gravity-M9 (ft-lbf)
Tile 2":12" 3":12" 4":12" 5":12" 6":12" Greater than
Profile 7":12"
Bella"High Battens Direct Battens I Direct Battens Direct Battens Direct Battens Direct Battens Direct
S"Tile Deck Deck Deck Deck Deck Deck
6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 1 5.68 1 6.33 1 5.50 6.13
.. ... . . . . . ..
. •
MIAMI•DADE COUNTY •`. ;. . NOA No.: 16-0112.06
• ••• • Expiration Date: 07/13/21
Approval Date: 02/25/16
�, • • Y • ••Y • • Page 3 of 5
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
Bella "High 2-10d Ring Shank Nails 28.6 41.2 19.4
S' Tile 1-10d Smooth or Screw 5.1 6.8 2.8
Shank Nail
2-10d Smooth or Screw 6.9 9.2 7.3
Shank Nails
1 #8 Screw 20.7 20.7 18.1
2 #8 Screw 43.2 43.2 29.8
1-10d Smooth or Screw 23.1 23.1 19.0
Shank Nail Field Clip)
1-10d Smooth or Screw 29.3 29.3 24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw 27.6 27.6 38.6
Shank Nails Field Clip)
2-10d Smooth or Screw 38.1 38.1 41.8
Shank Nails Eave Clip)
2-10d Ring Shank Nails' 33.1 48.1 50.9
1. Installation with a 4"tile headlap and fasterners are located a min. of 2'/z"from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella "High S"Tile Adhesive 29.32
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3M'2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella "High S"Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 66.53
3M'" 2-Component Foam Roof Tile Adhesive AH-160 38.74
3 Large patty placement of 63 rams of 3MT" 2-Component Foam Roof Tile Adhesive AH-160.
4 Medium patty placement of 24 rams of 3W 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance.Expressed as.a Moment-Mf(ft-lbf)
f6r Mortar'SQt Sys&As:
. .. . . . . ... .
Tile Profile --Tile�kcanon •• Attachment Resistance
Bella "High S"Tile Mortar Sets 24.5
. ... . ... ... .
5 Tile-Tite Roof Tile Mortar. . .
NOANo.: 16-0112.06
rtuvMFor►ne COU=NTYExpiration Date: 07/13/21
• Approval Date:02/25/16
Page 4 of 5
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail
below,or following statement: "Miami-Dade County Product Control Approved".
OR
ENTEGRR
ENTEGRA SALES BELLA"HIGH S"CONCRETE TILE LABEL
(LOCATED UNDERNEATH TILE)
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
a
13-x"
16.2 4
• •• • • • ••• •
•• • • •• • • • ••
END.OE CHIS A.0"PTANCT
Y
•
MIAMNOA No.: 16-0112.06
�ffnFDADE COUNTY
...sngj� Y Expiration Date: 07/13/21
Approval Date:02/25/16
"' . .'• • Page 5 of 5
. . . • • • . . . •
• .• ••. ..• . .• ..
... . ... . •
r . .
M1® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
` NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economy
ICP Adhesives and Sealants,Inc.
12505 NW 441i Street
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
a manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyse&AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the$gilrljpg DMIcial. . ..
This NOA renews NOA 16-0315.01 and consists of pages 1 through..l.•;
The submitted documentation was reviewed by Alex Tigera. "' •• •
t
• NOA No.: 17-0322.03
. . % . . . . . .
MIAMFWID;COUNTY • • ••• • ' 11:0ration Date: 05/10/22
Approval Date:04/27/17
... ... Page 1 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described
in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset'AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPacV N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset'AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch ,
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
$6.0%V.o121me Cl"e•@e AOF., 100%Humidity,2
weeks •• ••• •
Closed Cell Content ASTM D 2856 W6 . •': '
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal pnd4dfacturtng variadN. • •
• NOA No.: 17-0322.03
Muo MADE couNTY ••• txpiration Date: 05/10/22
Approval Date: 04/27/17
�. ... Page 2 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
f
{
t
4
EVIDENCE SUBMITTED:
Test Aaencv Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95,
25-7438-4
25-7438-7 SSTD 11-93 11/02/95,
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94+
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12'
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
5201.09-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
,
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, low, &high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof file adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code. .. ... ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
. .
.
•. NOA No.: 17-0322.03
.. :-0
. . .
uu
MMFaR►oe courv7ir
••• .•. .lxpiration Date: 05/10/22
Approval Date:04/27/17
0.0 ... i Page 3 of 11
. . . . V: . . . .
. .. ..
00
. •• ••
... . . . ... . .
INSTALLATION:
1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset®AH-160.
2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the"B" component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack®30& 1.00 dispensing equipment only.
7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset'AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details'herein. Each generic tile profile requires the specific placement noted herein.
.. • • .
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
• NOA No.: 17-0322.03
. . .. . . . . . •
Mu MMA�e CO=UNTY • • ••• • • .xpiration Date: 05/10/22
Approval Date: 04/27/17
... . • .•. Page 4 of 11
. . . . . . . . . .
. .. .. . . . .. ..
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq. inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq.inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel (Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead ,
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
MFIAMIQ%DE COUNTY
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
• •• • • • • ••• •
• ••• • ••• ••• •
• NOA No.: 17-0322.03
MIAMI-DADECOUNTY • • •• • • • • • • •
� � • ••• • Expiration Date: 05/10/22
Approval Date:04/27/17
••• • • Page 5 of 11
. . . . . • • . . .
... . . . ... . •
ADHESIVE PLACEMENT DETAIL# 1
Mgthroughplastic cvwtmt .PaddylBrnaaahr") Flat/Low Profile Tile
M
{wnroquir•d); ,y
Undrrls m■ne 1. Starting at the eave course,apply a minimum 2
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
j f paddy onto the underlayment positioned as shown,
��k '' • " under the strengthening rib closest to the overlock
•� to lm l •� `* .�+"/'� �., ••� -: •�,, of the the being set.
1111. l' �•�. \
Wtwnsaption01
EavaCours•.
2. Continue in same manner.Insure approximately 17
;f'�•� '`:, '` (109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
, Fascla
Nall through plastic cement Medium Profile/ Double Pan Tile
(when required)
Paddy{&rn■•thTil■1 1. Starting at the eave course,apply a minimum 2"
und*rlaymmt1 (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
h' ti �' ` w� `'• under the pan portion of the tile closest to the
overlock of the tile being set.
8anensopilanal w�: s, �;, 2. Continue in same manner. Insure approximately 17
m2)(109.7 cm2)—23 (148.4 square inch adhesive
�. contact with the underside of the tile.
Luc Closure
Emre tours• f r{ f` �' Fascia
I
hl■iltF=UOPlsael« nt- High Profile/Single Pan Tile
(wbenrcgwlree!} �! `�` Paddy 18*n■aehTil■i
th,d,rlaynm,tY 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10 (254 mm)x 1 (25.4 min)foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
Win..
ti 2 In.wlal• overlock of the tile being set.
�1
Battens �� /. - _, `�' - ��.�;�? 2. Continue in same manner.Insure approximately 17
optional t; ; ;�'`.,��- _. ` `` � (109.7 cm2)-23 (148.4 cm2)square inch adhesive
� .�jJ ��} °m.%��•f'r •jogWt yvith tyle u;dgrsidP.of the tile.
Eays Course- a /i /l a• • r • • •
fasda • •
• r• • • • • ••• •
t r ` Weepheie • • • • • • • • •
Eare closure •• ••• •• • • • ••
14inb`. 7in. 9 �'`f
."k, Orlp edge
• • • • • • • •
MIAMFC>tADE COUNTY •'r :. • •• : • • : • : : NOA No.: 17-0322.03
e • ••• • ' Apiration Date: 05/10/22
Approval Date: 04/27/17
r•. • • • ••• • •
Page 6of11
i
i
ADHESIVE PLACEMENT DETAIL#2
NAR throilgh plAmie inm•ns s paddy i8.n•*1hTilw'l Flat/Low Profile Tile
(whwnraquirad)� w ,r
URldk1>;7Yfl191Zt ve
4 1. Starting at the eave course, apply a minimum 2 (50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
i . ``=° ` -',� ` • ;�� the the being set. Insure approximately 17(109.7 cmz)
earc.nsoorxflai -' •,,tis_;;�.�� �,1 —23 (148.4 cmz)square inch adhesive contact with the
Eavw[oursa� �, a.., �, underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
Fascia x 7 (177.8 mm)x 1 (25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
Eavaaaeura..__^ a r, c 'F being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cmz)- 12(77.4 cmz)square inch adhesive
contact with the underside of the tile.
Nail through plastic temenl Medium Profile/Double Pan Tile
lwhen requiredi
`� 1 PaddyjOanemth'Ylla) 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
tlnd•daym
' onto the underlayment positioned as shown under the
�n!
pan portion of the tile closest to the overlock of the
ti's. ` ''; '`. the being set.Insure approximately 17(109.7 cm)—
23 (148.4 cm')square inch adhesive contact with the
t 3, may. underside of the tile.
Ba" ns optional
2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
E,;,.Clan" underlayment positioned as shown under the pan
portion of the the closest to the overlock of the tele
RCara{cmrow s"r s ss Fa►e a
s' being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2)- 14(90.3 em')square inch adhesive
contact with the underside of the tile.
(Ins4muclions contim%el og W page)
. .. . . . . ... .
•• ••• •• • O . ..
. ••• • ••• ••• .
TY
.
fee
e ;• ' •'• :•. • :•. : : NOA No.: 17-0322.03
MIAMI MADE couN
r ■, • • ••• • Efpiration Date: 05/10/22
Approval Date:04/27/17
•:• : • • Page 7 of 11
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
Nall through pfasucc ce ', High Profile/Single Pan Tile
When required) / ti� Paddy l0rrmalhril■7
1. Starting at the eave course, apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17(109.7 cm2)—
2In. � �. ` t 23 (148.4 cm2)square inch adhesive contact with the
Battens optional M`.� a' � underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
.. .. `
Ir EaveCou4xe
4 t �- Fascia x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
WPholo underlayment positioned as shown under the pan
104n. 2 An. � 5 portion of the tile closest to the overlock of the tile
�``�. •h � r'
011p,edge
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2)- 19(122.6 cm2)square inch adhesive
contact with the underside of the tile.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
• NOA No.: 17-0322.03
. . .. . . . . . . .
MIAMFDADe COUNTY ••• Expiration Date: 05/10/22
Approval Date: 04/27/17
••• ... Page 8 of 11
. . . . . . . . . .
ADHESIVE PLACEMENT DETAIL#3
Mail through plastic cement Paddy(between tiles)
twhenrequired) 1. On the eave course only,apply a minimum 2" (50.8
Banensoptional ° mm)x 10" (254 mm)x V (25.4 mm)foam paddy
° Daddy(under dle) onto the underlayment positioned as shown,under
single t� !1l the strengthening rib for flat tile or under the pan
V portion of the tile for low or high profile tile closest
'•4,•,``�q to the overlock of the tile being seta Leave
x4in tepad '4`•-, _ ,. approximately 4" (101.6 mm)up from the eave
Single paddy nn eras `�•,, ,• edge free of foam to prevent the expanded adhesive
onundedaymeM .�2x41n - from blocking the weep holes. Insure
� °r"•
approximately 17-23 int(109.7-148.4 cm2)of
loin adhesive contact with the underside of the tile
tin. Fascia
---EaveU0sure 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x l" (25.4
mm)foam paddy onto the underlayment just below
FlattLowlProfile Tile the second course line positioned foam paddy
under the strengthening rib for flat tile,or under the
Nail through plastic cement Single paddy under tile pan portion of the tile, closest to the underlock for
(when required)
Paddy(between tiles) the second course tile to be installed. Insure
approximately 8-9 int(51.6-58.1 cm2)of adhesive
Battens ( Paddy(undw tile) contact with the underside of the tile.
optional
Single . _ (Instructions continued on next page)
"4x4in. 2x41n.'-,�,
singlepaddyon
un9dayment _ -
•
Eave®osure
EareCourse Fascia
NIGdlum Profile Tile
.. ... . . . . . ..
.
••
. .. . . . ... .
. ••• • ••• •o: .
. o . . . .
. . .
• NOA No.: 17-0322.03
. . .. .
MIAMI•DADE COUNTY . • ••• •. .'. .'. Expiration Date: 05/10/22
Approval Date: 04/27/17
r 0:0 Page 9 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
a
NO through plastic Single paddy under the
twhenrequiredl 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x%"
1 va�yi�etwee"ole:i (19 mm)paddy on top of the eave course tile
Battens -� Paddy(undertde) surface as shown, on top of the strengthening rib
opti"'al for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile.Insure approximately
4x4in. _ ,�`'�,h 9(58.1 cm2)- 11 (71cm2)square inch adhesive
Sbo 2 x4 in �� contact with the underside of the tile at the overlap
e ,,- - and 7(45.2 cm2)-9(58.1 cm2)square inch
P `oo
tier- - adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
i Save Course—a. "y Fascia
_ Weephole
toin. zin. Eave closure
Drip edge
High ProflteTlla
• ••• • ••• ••• •
••• ;• +• : NOA No.: 17-0322.03
Mlar+Noaoecoin •" • Expiration Date: 05/10/22
Approval Date: 04/27/17
... . • ..+ . Page 10 of 11
. •• .. . . • •. .•
... . . • ... • •
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan)Tile
1. Starting at the eave course,apply a minimum 2"
in Place enough adhesive to achieve 65 to 70 sq in. Steep pitch applications
in contact with the pantile. (when required) (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
2►Turn covers upside down.Piace adhesive in paddy onto the underlayment positioned as
to 1 in.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave
Then install the tile.Ensure 20 to
25 sq.in.contact area. -�,-;� tiles from rocking until adhesive has a chance to
Iunderlayment -'- - cure.
♦ ' _ '' ° °
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65(419.4 cm2)—70(451.6 cm2)
square inch adhesive contact with the underside
Sheathing
of the pan tile.
Eave closure t�'
(motarshown) 3. Turn covers upside down exposing the underside
VA"hole Fascia Board of the tile.Apply a minimum 1"(25.4 mm)x 10"
(254 mm)bead of adhesive directly on the inner
Remove top portion of the save course cover die.Abut to second course of edge of each side of the cover tile. Leave
pan tiles.Ensure save end of pan and cover tiles are flush at save line. approximately 3/4"(19 mm)to 1"(25.4 mm)
Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20(129 cm2)-25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2"(50.8
mm)x 4"(101.6 mm)nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
.• ... . . . . . ..
• . ..
• . . . • . . •
.. ... .. . . . ..
1 •♦• • r•• •♦: •a•
♦ • • • • ♦ •
M(AMFUADE couNTY
00 0 :. • 0 • a • e NOA No.: 17-0322.03
..,• t • a '" a ' Expiration Date: 05/10/22
Approval Date: 04/27/17
••. . • • • 0016 • • Page 11 of 11
• •• •• • • • •• ••
�1 r
MIAMI•DADE
® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
Polyglass USA Inc.
1111 W.Newport Center Drive
Deerfield Beach,FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the reque$t'Of d1t:BailVigg QJiCJa4••
This NOA renews and revises NOA No.l 5-0410.04 and co tst p sof is• � t g th •u
res
pmh
The submitted documentation was reviewed by Freddy Sgmiq p
--s-00_-. • • • •
• •• • • • • • • •
NOA No.: 17-0614.22
MIAMaDADE COUNTY Expiration Date: 09/13/21
' Approval Date: 07/06/17
... . . . ... . .
Page i of 8
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Category: Underlayment
Material: SBS, APP Self-Adhering Modified Bitumen }
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65'x 3'3_3/8" ASTM D 1970 A fine granular/sand top surface self-adhering,APP
Manufacturing Or 65'x 3' polymer modified, fiberglass reinforced,bituminous
Location#1  60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice&rain shield.
Polystick Dual Pro 61'x 3'33/8' TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location#2 metal roofing and roof tile underlayment.
Polystick Tile Pro 61'x 3'33/8' TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location#2 roofing and roof tile underlayment.
Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced
Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as aia roof tile
Location#I  underlayment.
Polystick TU P 32'10" x 313/8' TAS 103 and A rubberized asphalt waterproofing membrane,glass-
Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface
Location#2 designed for use as a tile roof underlayment.
Polystick TU Plus 65'x 3'33/8' TAS 103 and A rubberized asphalt self-adhering,glass-'fiber/polyester
(Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Manufacturing roofing and roof tile underlayment.
Location#1 
Polystick MTS 65'8" x 313/8 TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus 65'8" x 3'3 3/8 TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Elastoflex S6 G 32'10" x 3'3-%" TAS 103 and ..PQVpster rei aforced, SSS modified bitumen membrane
Manufacturing
ASTM D 6164 witlya saAd@*d baek ;Fase and a granule top surface. For
Location#2 ..•u%;.l�r rggf Ai e-u0*dg...rl4yment systems.
. ... . ... ... .
. . .. . . . . . . .
CMLAMM�ALDE Coin NOA No.: 17-0614.22
- ... ... Expiration Date: 09/13/21
:.: Approval Date: 07/06/17
. .. .. . . . .. ..
Page 2 of 8
... . . . ... . .
k
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Trinity ERD P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798&G 15 5 09/01/11
P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11
P40390.08.12-2 ASTM D 1623 08/07/12
P37590.07.13-1 ASTM D6164 07/02/13
P45270.05.14 TAS 103,TAS 110&ASTM D1623 05/12/14
P46520.10.14 ASTM D1623 10/03/14
P44360.10.14 TAS 103 &TAS 110 10/07/14
P43290.10.14 ASTM D 1970&TAS 110 10/17/14
PLYG-SC10130.06.16-3 TAS 103 &TAS 110 06/27/16
PLYG-10130.06.16-1 ASTM D1970&TAS 110 ' 06/27/16
PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09
Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798&G155 04/01/08
RX14E8A TAS 103/ASTM D4798&G155 11/09/09
DX23138B TAS 103/ASTM D4798&G155 02/18/10
DX23D8A TAS 103/ASTM D4798&G155 02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMMADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
.• ... . . . . . ..
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or appl3ablabuiI&ng ooda•in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
MIAMFDADE COU
...� � •.. . . .•. Expiration Date: 09/13/21
•: : Approval Date: 07/06/17
s :•••: �•�+�
Page 3of 8
.•. . • . ... . .
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick
TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus, self-adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1.518.2& 1518.4 Nails and tin caps 12" grid,6" o.c.at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type lI or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c.at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self-adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus,self-adhered.
Surfacing: See General Limitations Below.
. .. . . . . ... .
r
• ••• • ••• ••• •
• • • • • • • •
• • •• • • • • • • •
NOA No.: 17-0614.22
MIAMFDADE COUNTY
� ,... � � ..,, • • . • ••. • . Expiration Date: 09/13/21
i i i i•i i i Approval Date: 07/06/17
:•••: : : :.•+:
Page 4of 8
••• . • • .•• . .
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3"and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention
to lap areas.
7. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems on:y.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max;Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times;not to exceed the preceeding maximal 4"e 1,4tat1ons,
Ex osure LifWtati s •
MTS IR-Xe Elastoflex TLL AM Ve pra .Jlual Pro TU Max MTS Plus
S6 G Plus
Winter Haven,FL 180 90 180 180 180 180 180 180 180
Hazelton,PA N/A 90 N/A SO N/A • /A A 180 N/A
7. All products listed herein shall have a quality assZw;ncaaudit-%qm�accordance-witlrt*he Florida Building Code and
NOA No.: 17-0614.22
Muworwe Coun�r�r •• Expiration Date: 09/13/21
:.: Approval Date: 07/06/17
. . . . . . . . . .
• •• •• •• ••
Page 5of 8
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope
shall be as follows: (See Table Below)
Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3)
Profile MTS S6 G TU P,Tile Pro, TU Max MTS Plus MTS Plus with
Dual Pro TU Plus
Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12
without battens
Profiled Prohibited 4:12 6:12 6:12 4:12 6:12
Tile without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure—two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope,for a total of 6 tiles—for
all underlayments except Polystick MTS which shall be loaded onto battens.
-- ------------------- (6 Max. Per Stack)
i
m 12
0FL6
N
N
r
i0
POL'6nCKTU Plus
t
•• ••• • • • • • ••
• •• • • • • ••• •
•• ••• •• • • • ••
• ••• • ••• ••• •
• • •• • • • • • • •
NOA No.: 17-0614.22
MIAWWDE COUNTY ••• ••• Expiration Date: 09/13/21
:.: Approval Date: 07/06/17
. . . . . . . . . .
.. .. .. .. Page 6 of 8
... . . . ... . .
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
Bella "High 2-10d Ring Shank Nails 28.6 41.2 19.4
S' Tile 1-10d Smooth or Screw 5.1 6.8 2.8
Shank Nail
2-10d Smooth or Screw 6.9 9.2 7.3
Shank Nails
1 #8 Screw 20.7 20.7 18.1
2 #8 Screw 43.2 43.2 29.8
1-10d Smooth or Screw 23.1 23.1 19.0
Shank Nail Field Clip)
1-10d Smooth or Screw 29.3 29.3 24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw 27.6 27.6 38.6
Shank Nails Field Clip)
2-10d Smooth or Screw 38.1 38.1 41.8
Shank Nails Eave Clip)
2-10d Ring Shank Nails' 33.1 48.1 50.9
1. Installation with a 4"tile headlap and fasterners are located a min. of 2'/z"from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella "High S"Tile Adhesive 29.32
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3M'2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella "High S"Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 66.53
3M'" 2-Component Foam Roof Tile Adhesive AH-160 38.74
3 Large patty placement of 63 rams of 3MT" 2-Component Foam Roof Tile Adhesive AH-160.
4 Medium patty placement of 24 rams of 3W 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance.Expressed as.a Moment-Mf(ft-lbf)
f6r Mortar'SQt Sys&As:
. .. . . . . ... .
Tile Profile --Tile�kcanon •• Attachment Resistance
Bella "High S"Tile Mortar Sets 24.5
. ... . ... ... .
5 Tile-Tite Roof Tile Mortar. . .
NOANo.: 16-0112.06
rtuvMFor►ne COU=NTYExpiration Date: 07/13/21
• Approval Date:02/25/16
Page 4 of 5
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
i
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU
Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro,
Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick
TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area, area para clavar"on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric;and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the'Polyglass Tile
Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the tile manufacturers NOA,must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/."/12",precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed
roof to wall details.
9. Re air'of Polystick membranes is to be accom lisli �b a *1� o of lus 55 Premium Modified
P Y p � Y Pb�i1i$� 1�'��L' YP
Flashing Cement,Polyglass Polyplus 50 Premium MBFlaglirig�'eTinant;5*ra?lex 50 Premium Modified
0 090Wet/Dry Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching
membrane shall be a minimum of 6 inches in eiths?direction. THe'r4pair should be installed in such a way so
that water will run parallel to or over the top of all+s of the patch
MIAMMADE COUNTY NOA No.: 17-0614.22
... . ... . Expiration Date: 09/13/21
' Approval Date: 07/06/17
Page 7 of 8
... . . . ... . .
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800)894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800)894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association(NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
.. ... . . . . . ..
.. ... .. . . . ..
• • • • • • • •
• • •• • • • • • • •
OMIA COUNTY NOA No.: 17-0614.22
EWNX$ Expiration Date: 09/13/21
% Approval Date: 07/06/17
;•••� ; ; ; ;.•.;
Page 8of 8
•.• . • • ••. • •
MIAM MIAMI DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Rom 208
BOARD AND CODE ADNM41 MTION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.mi9�idaao.gov/�°�umv
Polyglass USA,Inc.
150 Lyon Drive
Fernley,NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:Polyglass Self-Adhered Roof System over Wood Decks
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/ manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply'with any section
of this NOA shall be cause for termination and.removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building O.ffici. .al.
.. ... . . ..
This NOA renews NOA# 13-1217.01 and consists of pages 1 throug� . : : •; •••
The submitted documentation was.reviewed by Alex Tigers.•• ••• •• ••
. .. ••• 000
.• NOA No.: 17-1004.09
• ••• Expiration Date: 10/11/22
Approval Date:10/19/17
... ••• Page 1 of 34
. . . . .. . . . . .
ROOFING A53EM$LY APPROVAL
Roofing
Sab-Ca orv: Modified Bitumen
SBS/APP/`I'PO
Dock Type: Wood
1p aftm
-112.5,psf
TRADE NAMES OF.PRODUCTS MANUFACTURED OR LABELS BY APPLICANT:
TAME 1
Test Product
froduct DimSnecma
Elastobase 65'V x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced
Type I base sheet..
Xtranex SBS Glass 65' 8"x 3' 3-3/8" ,ASTM D 6163, SBS modified asphalt coated fiberglass reinforced
Base Type 1 base sheet.
P61yglass'G2 Base 108'x 36' ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet
Type'll
Polyanchor 250' x48" ASTM D 4601 A polymer woven,high performance,synthetic base
Type 11 sheet..
Elastobase P 65' 9"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base
Type I %sheet.
Elastoflex SA V FR 66' 8"x 3' 3-3%8" ASTM D 6163, Self-adhered, -*-M4 fiberglass reinforced,SBS
Type T modified bitumen membrane with a self-adhering back
face and a smooth top surface.
Elastoflex SA V 66' 8"x 3'3-3/8" :ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced+SBS
PLUS FR Type I modified bitumen membrane with a self-adhering back
face and a smooth top surface.
Elastoflex SAV(1.5- 66' 8''x 3'3 3/s" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified
Type I bitumen membrane with a self-adhering back face and
a smooth top surface.
Elastotlex SA V 66' 8"x 3' 3-Yo" ASTM D 6163, Seif adhered,fiberglass reinforced,SBS modified
;PLUS TYP e I bitumen membrane with a self-adhering back face and
:a.smooth top surface.
XtraFlex SBS Base 66' 8"x 3 3 ls" ASTM D 6163, Self adhered,fiberglass,reimforced,SBS modified
`SA 'Type I bitumen membrane with a self-adhering back face and
a smooth top surface.
Vastoflex SA P FR `32' 10"x 3'.3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced,SBS
Type I .. KedLbitwnep wmbrane'witb a self-adhering back
fac4 and g ide=op surface.
:.. . . .. . ..: . .
XtraFlex SBS G SA 32' 10''x 3'3-3/8'' ASTM D 6164,•So%adh&.Fib-*ted,'polyester reinforced,SBS
Type I modified bitum 6n membrane with a,self-adhering back
face and g grpltule suXface.
. .. .. . . . . . . .
NOA No.: 17-1004.09
• ••• Expiration Date: 10/11/22
... ••• Approval Date:'10/19/17
• Page 2 of 34
Elastoflex SA P 32' 10"x 3' 3�63/8" ;ASTM D 6164, Self-o4emdfiberglaasi*info.wedSB$modiiied
Type I bitumen membrane with a self-adhering back face and
a gramle top surface.
Polyflex 32'.10'0013-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bteimaen membrane with a burn off polyethylene back
;face and a smooth or sanded.top surface.
'XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
;Polybond 32' 10"x 3'3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a burn offpolyethylene back
face and a smooth or sanded top surface.
Polyflex G 32' 10"x 3'3-3/8" ASTM D 6222 Torch.applied,polyester reinforced,APP modified
bitumen membrane with a bum off polyethylene back
face and a granule top surface.
Polyflex$A P 32' 10"x 3'3-Ns" ASTM D 6222, Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and.
'a granule top surface.
Polyflex SA P FR 32' l0"x 3`33/s" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP
Type'I modified bitumen membrane with a self-adhering back
face and a granule top surface. ,
XtraFlex APP G SA 32' 10"x 3' VA" ASTM D 6222, Self-adhered,fire-ratted,polyester reinforced,APP
Type I :modified bitumen membrane with a self-adhering back
;face sad a granule top surface.
Polyfresko G SBS SA 32' 10"x 3' 33/s" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified
Typel bitumen i
membrane with a self-adhe rng back face and
A granule top surface. E
Polyfresko G SBS SA 12' 10"x 3' Ph" ASTM D 6164, Self-adhered,fire-rated,fiberglass reinforced,SBS
FR Type`I modified bitumen membrane with a self-adhering back
face and a granule top surface..
:Polyfresko G APP$A 32' 1Q"x 3'33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
Polyfresko G APP SA 32' 10"x 3'3-3/,11 ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP
F Type i modified bitumen membrane with a self-adhering back
We and a granule top surface
PolyKool 32' 1Q"x 3' 3-3/s" :ASTM D6222 Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with,a self-adhering back face and
a white film laminate on the top'surface.
XtmFlex Koo1 APP S 32' 10"x 3'3-3/s" ASTM D6222 Self-adhered,polyester reinforced,APP modified
T I .•• In uianen:membrane M a self adhering back face and
A. •• • 0 the to surface.
a 1p� u p
#61yglass APP Base 65' 8"x 3'3 3/s." ASTM D 6564 APP .modified asphalt coated fiberglass reinforced
Type I, base sheet,
• ••• NOA No.: 17-1004,09
Expimflon Date: 10/11/22
... ... Approval Date: 10/19/17
• :.: Page 3 of 34
••• • • • 600 •
PG325 Cold Process 1,3,5,500 55 gal.or ASTM D3019 A ffbered cold process adhesive for use with roll or .
Adhesive tube Type M BUR roofing.
PG100 Asphalt Primer 1,,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of
tube or 17 oz.spray selected asphalts used to promote adhesion.
can
f
xtraFlex 10 Asphalt 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of
Primer tube or 17 oz.spray selected asphalts used to promote.adhesion.
can
PG350 Mod Bit 1,3,5,500 55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use.with
Adhesive tube Type M modified bitumen membranes.
PG400 Plastic Roof 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in
Cement tube ASTM D3409 dry or damp conditions.
PG425 WeVDry Roof . 12 3,5,509 55.991.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in
Cement. tube ASTM D3409 . dry or damp conditions.
13IG450 Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement.
Cement tube
;PG500 MB Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use
Cement tube with modified bitumen membranes.
'Polyplus 35 Premium 1,3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with
;Mod Bit Adhesive tube Type'lIl ;modified bitumen membranes.
ftaFlex 35 premium 1,3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with
Mod Bit Adhesive tube Type III modified bitumen membranes.
Polyplus 45 Premium '1,3,5,50,55 gal.or ,ASTM D4586 A thick,fibered,rubberized flashing dement.
Flashing Cement tube
Polyplus 50 Premium i,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use
MB Flashing Cement tube with modified bitumen membranes.
XtraFlex 50 Premium 1,39 5,50,55 gal.or ASTM D4586 A thick,Abered,rubberized flashing cement for use
Modified Wet/Dry tube with modified bitumen membranes...
.Cement
Polyplus 55 Premium 1,3,5,$0,55 gal.or ASTM D4586 A mastic compound for use as a roof flashing
Modified Flashing tube adhesive.
Cement
I
VOA No.:. 11-1004-69
• ••• Expiration bete. 10/11/22
... ..• ,Approval Date: 1049/17
• page 4 of 34
1
APPROVED INSULATIONS:
TABLE 2
pie product Desc onI
(With Current NOA)
Polytherm-H Polyisocyanorate foam insulation Polyglass USA,Inc.
Polytherm Polyisocyanurate foam,insulation Polyglass'USA,Inc.
ACFoam-lI Polyisocyanurate foam insulation Atlas Roofing Corp
ACFoam III Polyisocyanurate.foam.insulation :Atlas Roofing Corp
High Density wood Fiberboard wood fiber insulation board Generic
.DensDeck,DensDeck Prime Gypsum insulation board Georgia Pacific Gypsum LLC
'H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC
H-Shield CO polyisocyanurate/perlite composite insulation Hunter Panels,LLC
ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp.
f
Fesco Board ;Expanded mineral fiber Johns Manville Corp.
Multi-Max FA-3 Polyisocyanuratefoam insulation Rmax Operating,LLC.
SECUROCK Gypsunt-Fiber Roof Board Fiber reinforced covaboacd United States Gypsum
Corporation
. .. ... . . . . .. ..
•,• ;'
000
• NOA No.: 17-1004.09
,Expiration Date: 10/11/22
„ ;Approvsl Date:10/19/17
. ... Doge 5 of 34
t
i
APPROVED FASTENEMO
TABLE 3
Elam MR04MMLer
i it�g g ;RMA WIM QWnsigns (With Current NOM
1. Dekfast Fasteners 12, 14 8t Insulation fastener for wood, SFS Intec,lac.
5 HS ,steel and concrete decks
2.. DeIdU Galvalume Steel Galvalume hex stress plate. 2 7/s"x SFS b tec,Inc.
`Hex Plate
3. #14 Roofgrip Insulation and membrane Various OMG,Inc..
fastener
A Flat Bottom Metal Plate A2-SS aluminized steel plate 3"square 1.OMG,Inc._
5. Trust#14 RD Fastener Insulation fastener for steel and Altenloh,Brinck&Co.
wood docks U.S.,Inc.
6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&.Co.
Plate plate 3"round U.S.,Inc.
7. Po.ygnp Fasteners#12,#14 Insulation fastener for wood, Various ;Polyglasa USA,Inc
 steel and concrete decks
8. Polygrip Hex Plates Galvalume hex stress plate. 21/0 x Polyglass USA,Inc
.. ... . . . . . ..
. . .. . . . . ... .
NOA No.: 17-1004.09
Exph*don Date: 10%11/22
... ... .
.;Approval Date:10/19/17
:': Page tot 34
APPROVED SURFACING:
TABLE 4
pradg_a AR&!AN ;S� aManufactur
FALe
PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1%-2 pVsqTAS 140 Polyglass
to add life and rejuvenate existing MA,Inc.
OUR roofing substrates.
XtraFiex 20 Bituminous Roof ,A,uon fibered,asphaltic coating used .1%-2 gal/sq TAS 140 , Polyglass
Coating to add life and rejuvenate existing `USA,Inc.
BUR roofing substrates.
P0300 Fibered Roof Coating An asphalt cutback.fibered roof :1 Y2-2 gal/sq ASTM D4479 Polyglass
coating. May be applied by brush or `USA,Inc.
.spray equipment to rejuvenate aged
BUR
XWLFlex Bituminous Roof An asphalt cutback fibered roof 1'%=-2 gal/sq ASTM D4479 Polyglass
Coating Fibered coating. May be applied by brush or USA,Inc.
spray equipment to rejuvenate aged
:BUR
TG600 Non Fibered Aluminum Non-fibered aluminum roof coating. ''/a-1 gal/s4 ASTM D2824 Polyglass
;Roof Coating Type I USA,Inc.
:PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 'I'/s-2 gWsq ASTM D2824 Polyglass
Coating Type III USA,Inc.
PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/z,pVsq ASTM D6083 Polyglass
'based roof coating(water-based). A USA,Inc.
polyester fabric may be used for
reinforcement with this coating.
PG800 Non:Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass
Emulsion Roof Coating .emulsion two coats USA,Inc.
XbvMcx 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polygl"s
Coating emulsion two coats USA,Inc.
PG850 Fibered Asphalt Emulsion An asphalt base,fibered clay 3 gal/sq in :ASTM D1227 Polyglass
,Roof Coating emulsion :two coats 'USA,Inc,
Polyplus 65 Premium Fibered. Fibered aluminum roof coating. 1%-2 gal/sq ASTM D2824 Polyglass
Aluminum Roof Coating Type III `USA,Inc.
XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 114-2.gaUsq ASTM D2824 Polyglass
Coating Fibered Type III USA,Inc.
Polyplus 60 Premium Non- Non-fibered aluminum roof coating. '/s-1 gaUsq ASTM D2824 Polyglass
Fibered Aluminum Roof Coating .. ... . . . ..Type I USA,Inc.
;XtraFlex 60 Aluminum Roof Non-fibered aluminum.roof cohting..: WJ:g d94. ASTM D2824 Polyglass
'Coating •.' ..: '.: '.' ..'Type I IDSA,Inc..
. ... . ... ... .
e
N0A..No.: t7-10040
... ... .Eiplratlon Date: 10/11/22
Approval Data: 10/19117
• Ne 7 of 34
... . . . ... . .
APPROVED SURFACING:
TAS 4
AMC
! lV�a ufactar
lflcation
Ir
Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/s pVsq ASTM D600 Polyglass
,Elastomeric Roof Coating 'based roof coating(water-based). A USA,Inc.
polyester fabric may be used for
:reinforcement with this coating.
mFlex 70 Premium Acrylic FR A premium white elastomer c acrylic 1-1'/:pVsq ASTM D6083 Polyglass
Roof Coating based roof coating(water-based). A 'USA,Inc.
polyester fabric maybe used for
reinforcement with this coating.
Polybrite 90 High Solids Silicone A premium grade high solids,single 1.25 gallsq ASTM D6694 Polyglass
'Roof Coating component,moisture cure,fluid USA,Inc.
applied silicone coating
'XtraFlex SRC 9600 High Solids A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass
Silicone Roof Coating component,moisture cure,fluid USA,Inc.
applied silicone coating
Polybrite 95 Silicone Roof A single component,solvent, 1.25 gaysq ASTM D6694 Polyglass
Coating ;moisture cure silicone coating. USA,Inc.
°XtraFlex SRC 8000 Silicone Roof A.single component,solvent, 1.25 gaUsq ASTM D6694 Polyglass
'Coating moisture cure silicone coating. USA,Inc,
'Gravel To be installed in a flood coat of 400 lbs/sq N%AGeneric
:.approved asphalt at 60 lbs/sq
Slag To be installed in a flood,coat of 300 lbs/sq N/A Generic
.approved asphalt at 66 lbs/sq
• • • • • • • •
• • •• f • • • • • •
• • ••• • • •
WOA No.: 17-1004.9
••• ••• • Expiration Date: 10/11/22
• . Y • Approval Dato:10/19/17
• ••• Page I of 34.
EVIDENCE guim I m
Test ABY Test Ret. .9� Date
Factory Mutual Research 4470 2W7A7.AM 08.04.94
Corporation 4450 .2D5A9.AM 06.22.99
4470 3001334 02,15,00
4470 ;3000857 01.12.00
4470 ;3004091 01.12.00
4470 3012321. 07.29.07 .
4450 3614151 08.27.03
4450 3019317 06.30.04
4470 '3014692 08.05.03
Trinity I ERD TAS 114 11752.69.99-1 02.08.00
TAS 114 ;02764.09.05 0.09.65
TAS 114 02762.03.05 03.30.05
TAS 117(B)-ASTM D903 020841.06,04 06.02.04
TAS 114 T1734.07.06-R1 02.27.07
TAS 114 P1,738.02.07 02.05.07
TAS 114 P1739.01.07 01.23.07
TAS 117(B)-ASTM D6862 C8500SC.11.07 :11.30.07
ASTM D6164/ASTM D6222 ;P 10490.08.08 08.13.08
ASTM D6164/ASTM D6222 P10490.10.08--R1 ;10.03.08
ASTM D6222 "P7400.03.0842. '10,09.08
TAS 114(D)—ASTM D 1876 P1070.10.08 10.09.08
ASTM D6222 P10490.10.08-2 10.30.08
FM 4470 8t TAS 114 P33970.03.11 03.15.11
,ASTM D6163/ASTM D 4601 P33960.03.11 03.15.11
TAS 114 8t TAS 117(B) 11757.12.00-1-R1 04.29.13
TAS 114&TAS 117(B) 11757.04.01-1-R1 04.30.13
ASTM 06164 P37590.07.13-1 07.02.1.3
ASTM D6164 P37590 .03.13-3A 03.06.13
ASTM D6163 P37590.03.13-2-R! 02.05.13
-ASTM D6222. P37590.09,13 09.12.13
ASTM D4601%TAS 117 P45940.09.13 49.04.13
TAS 114&FM 4474 ;P41630.08.13 08.06.13
TAS 114(H) P13760.09.09 09.10.09
ASTM D4061 %TAS 117 ;P45970.05.14 05.12.14
;PRI Construction Materials ASTM D6222 . PUSA-061-02-02 01.28.08
`Technologies
ASTM D6222 PUSA-062-02-02 :12.04,08
ASTM D6163 :PUSA-064-02-02 02.27.08
ASTM D6694 000 ••; PjJSE4 34-62-01 05.16.14
ASTM D6694 '. r; ,Pvw3t E91 05.1.6.14
r
NOA No.: 17-1004..09
••Y • • •,• • • .xplmden Date 10111/22
• .Appre**1 Date:10/19/17
• %'
.1 Page 9 of 34
• •• •Y • • •• ••
I
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: "132"or.greater plywood or wood plank,fastened at 24"spans with 8d common nails at 4"o.c.
or#8 wood screws at V o.c.
System Type E(1): Base sheet is mechanically attached to roof deck.
AU General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved
and.shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building
Code requirements and are Held fabricated utilizing the approved membranes listed in Table 1.
Base Sheet: One ply of Elastobase,XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the
deck as described below:
Y
Faso gjpg: Attach base sheet using l l.ga.annular ring shank nails and 1-5/8"diameter tin caps spaced 8"
o.c.in a 4"lap and 8"o.c.in three equally spaced staggered rows in the center of the sheet.
t
Ply Sheet: One or more plies of Elastoflex SA V(1.5:mm),Elastoflex SA V PLUS,XtraFlex SBS Base
SA,Elastoflex SA V FR(1.5 mm)or Elastoflex SA V PLUS FR,self adhered.
Membrane: One ply of Poly&esko G SBS SA,Polyf-esko G SBS SA FR,Polyf vsko G APP SA,
Polyffesko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex
SA P,PolyKool,XtraFlex K000l A SA,Polyflex SA P FR or XtraFlex APP G SA,self.
adhered
Or
One ply of Polyflex G,torch-applied
Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure: -52.5 psf,(See General limitation V.).
.. ... . . . . . ..
. . . .. . . . . .
. .. . . . . ... .
.. ... .. . . . ..
••• ••• ••• 13OA No.: 17-1004.09
Expiration Date: 10/11/22
••• ••• Approval Date:10/19/17
Page 26 of 34
. . . . . . . . . .
'WOOD DECK SYSTEM LIMITATIONS:
`l. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation maybe installed in multiple layers. The first layer shallbe attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the.EVT range and at a rate of 2040 lbs./sq.,or mechanically attached using the fastening pattern of the
top layer`
3. All standardpanel.sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size
shall be 4'x 4'maximum,
4. An overlay and/or recovery board insulation panel is required on all applications over closed cel I. foam.
insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using
spot mopping with approved asphalt, 12"diameter circles,24"o.c.;or strip mopped 8"ribbons in three rows,one
at each side lap and one down the center.of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every l2'in each ribbon to allow cross ventilation. "Asphalt
application of either system shall be at a minimum.rate of 12 lbsJsq.
.Notes Spot attached systema shall be'limited to a maximum design pressure of-45 psi.
5, Fastener spacing for insulation attachment is based'on a`Minimum Characteristic Force(P)value of 275 lbf.,as.
tested in compliance with Testing App lication,Standard TAS 105, If the fastener value,as field-tested,are below
2751bf insulation attachment sha11 not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
;fastener resistance value in conjunction with the maximum design value listed within a specific system. 'Should
the fastener resistance be less than that required,as determined by the Building Official,a revised fastener
spacing,prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or
Registered Roof Consultant maybe submitted. Said revised fastener spacing shall utilize the withdrawal
;resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117,
7. 'Perimeter and comer areas shall comply with the enhed ancuplift pressure requirements of these areas. 'Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
,Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
;Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA,General Limitation.#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform'to
Roofing Application Standard RAS 111 and applicable wind load requirements,
9. The maximum designed pressure limitation listed shall be,applicable to all.roof pressure zones.(i.e.field,
;perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e.perimeters,extended corners and corners).(When this limitation is specifically
,referred within this NOA,General Limitation#7 will.not be applicable.)
14. All products listed havin.shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61020-3 of the Florida Administrative Code. 00
END OF THIS ACCEPTS
. . .. . . . . . . .
NOA.No.: 17-1004.09
Ex iration Date: 10/11/22
:. Approval Date:10/19/17
• • • •` • Page U of U
1
TGFU.R14571 -Roofing Systems Page 5 of 15
Base Sheat:—'ELASTOBASE","XtreFlex SBS GLASS Base"(poly/sand),mechanically fastened or'ELASTOFLEX SA V PLUS FR",
"ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT"(self adhered).
Ply Sheat(Optional):—'ELASTOBASE","XtraFlex SBS GLASS Base"(pdy/sand),heat fused or mechanically fastened,or'ELASTOFLEX
SA V PLUS FR","ELASTOFLEX SA V FR"or'ELASTOFLEX SA V FR BASE VENT",(self adhered).
Membrane:—"POLYFLEX SA P FR","POLYFRESKO G APP SA P FR',"ELASTOFLEX SA P FR",'PoLYFRESKQ G SBS SA P FR',
'ELASTOFLEX SA V FR HT",(self adhered)or"POLYFLEX G FR",'XtraFlex APP G HP","Xtraflex APP G FR',"POLYFRESKO G FR','DUFLEX
G FR",'XtraFlex APP Dual",'ELASTOFLEX S6 G FR",'POLYFRESKO G SBS FR","ELASTORB(VG FR","XtraFlex SBS POLY G","X"Fiex
SBS POLY G T","XtraFlex SBS GLASS G',"XtraFlex SBS GLASS GT"or"ELASTOSHIELD TS G FR",heat fused.
Deck:C-15/32 Indirm 1/2
Insulation(Optional):—Polylsocyanurate 1.5 in.(min.)with all joints staggered 6-in.(min.)frau the plywood joints.
v Bass Sheet:—Type G2,mechanically fastened followed by` ,"XiraFlex SBS GLASS Base",mechanically fastened.
Ply Sheet(Optional):—'ELASTOFLEX SA V PLUS FR',-E "or"ELASTOFLEX SA V FR BASE VENT",(self adhered).
Membrana:—"POLYFLEX SA P FR","POLYFRESKO G APP P FR",-ELASTOFLEX SA P FR',-POLYFRESKO G SBS SA P FR",or'DUFLEX
G FR",'XtraFlex APP Dual","POLYFLEX G FR","XtraFlex APP G HP'," LASTOFLEX S6 G FR","POLYFRESKO G SBS
FR","ELASTOFLEX VG FR',"XtraFlex SBS POLY G',"XtraFIex SBS POLY G T','XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or 1
"ELASTOSHIELD TS G FR',heat fused.
23.Deck:NC Incline:2
Insulation(Optional):—'Polythene",Atlas Roofing'ACFoam III"or"ACFoam II'or Hunter Panels'H-Shield",any thickness.
Bass Sheet:—"ELASTOBASE","XtraFlex SBS GLASS Base'(poly/sand),heat fused or mechanically fastened or"ELASTOFLEX SA V FR",
"ELASTOFLEX SA V PLUS FR"or"ELASTOFLEX SA V FR BASE VENT",(self adhered).
Membrane:—"POLYFLEX SA P FR',"POLYFRESKO G APP SA P FR",'ELASTOFLEX SA P FR","POLYFRESKO G SBS SA P FR",
"ELASTOFLEX SA V FR HT',(self adhered)or"POLYFLEX G FR',"XtraFlex APP G HP","Xtraflex APP G FR","POLYFRESKO G FR','XtraFlex
APP Dual","DUFLEX G FR',"ELASTOFLEX S6 G FR","POLYFRESKO G SBS FR',"ELASTOFLEX VG FR',"XtraFlex SBS POLY G',"XtraFlex
SBS POLY G T",'XtraFlex SIBS GLASS G","XtraFlex SBS GLASS GT"or"ELASTOSHIELD TS G FR',heat fused.
24.Deck:C-15/32 Incline:3
Insulation(Optional):—Polyisocyanurate,perlite,wood fiber or polyisocyanurate/perlite board,any thickness.
Barrier Board:—1/4 In.(min)G-P Gypsum DensDeck®,mechanically fastened with all joints staggered 61n.from the plywood joints.
Base Sheet:—"ELASTOBASE","XtreFlex SBS GLASS Base"(poly/sand),mechanically fastened.
Ply Sheet(Optional):—"ELASTOFLEX SA V PLUS FR","ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT',(self adhered).
Membrana:—'ELASTOFLEX S6 G FR',"XtraFlex SBS POLY G","XtraFlex SBS POLY G T"or"POLYFRESKO G SBS FR",heat fused.
25.Deck-NC Indine•3
Insulation(Optional):—"Polytherm",Atlas Rooflng"ACFoam III"or"ACFoam IP or Hunter Panels"H-Shield',any thickness.
Bow Shoat:—"ELASTOFLEX SA V PLUS FR-,"ELASTOFLEX SA V FR`or"ELASTOFLEX SA V FR BASE VENT'(self adhered).
Membrane:—"POLYFLEX SA P FR","POLYFRESKO G APP SA P FR",'ELASTOFLEX SA P FR"or"POLYFRESKO G SBS SA P FR"(self
adhered).
26.Deck:NC InciM:1/2
r
Base Sheet: Type GI or G2,mechanically fastened.
Membrane:—"POLYFLEX G',"XtraFlex APP G HP TOR",'Xtraflex APP G"or"POLYBOND G",heat fused.
27,Dedc NC Incline:3
Membrane:—"POLYFLEX SA P FR","POLYFRESKO G APP SA P FR","POLYFRESKO G SBS SA P FR'or"ELASTOFLEX SA P FR'(self
adhered).
28,Dedc NC Incline:1
Insulation(Optional):—Polylsocyanurete,any thickness.
Base Sheet(Optional):—"ELASTOFLEX SA V","ELASTOFLEX SA V PLUS","Xtraflex SBS Base SA"or"ELASTOFLEX SA V BASE VENT',
self-adhered or"ELASTOBASE",-XtraFlex SBS GLASS Base'(poly/sand),mechanically fastened.
Membrana:—"POLYFLEX SA P',"Xtraflex APP G SA"'XtraFlex Kool APP G SA",or"POLYFRESKO G APP SA P"self-adhered or"POLYFLEX
G FR',heat fused.
29.Deck:C-15/32 Incline:1/2
Insulation:—Polylsocyanurate(2 in.min),glass fiber(15/16 in.min),perlite/polyisocyanurabe composite,perlite/urethane composite
(21n.min).
Barrier Board:—1/4 In.(min)G-P Gypsum DensDeekO,mechanically fastened,with 61n.offset to plywood joints.
Base Sheet:—"ELASTOFLEX S6',"XtraFtex SBS POLY Base","ELASTOFLEX P-C'(heat fused.or mechanically fastened).
Membrane:—"ELASTOFLEX S6 G',"ELASTOFLEX S6 G-C"or'POLYFRESKO G SBS",(heat fused).
30.Oeek:NC Incline:1/2
Insulation(Optional)—"Polythene`,Atlas Roofing'ACFoam III"or"ACFoam II",any thidkoess•• • • • • • ••
Base Sheet:—'ELASTOFLEX SA V PLUS FR',"ELASTOFLEX SA V FR"or'ELASTOFLEX SjV FR BASD VBNTq(self srekl)
dhe . •
Membrane:—'POLYKOOL SA"or"XtraKool APP S SA",(self adhered). • •s •,• i i i•i •a
31.Detic 5/32
Incline:1/2 •• ••• a.: • • • ••
Base Sheet:—G2 Base sheet mechanically fastened followed by"ELASTOFLEX SA V PLUS FR',"ELASTOFLEX SA V FR"or"ELASTOFLEX
SA V FR BASE VENT',(self adhered). • • • • ••• ••• •
Membrane:—"POLYKOOL SA"or"XtraKooi APP S SA",(self adhered). • • • • • • •
• f • • • • • •
••• • • Y • ••J •
http://database.ul.com/egi-bin/XYV/template/LISEXT/1FRAME/sho4agt.htnll?DMe-T..; 10,15/2017