Loading...
RF-18-136 r 4 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores,FL Phone: (3015)795-2204 Fax:(305)756-8972 Inspection Number. IN813-301976 PermitNumber: RF-1-18-136 Scheduled Inspection Date:April 19,2018 Inspector:Naranjo, Ismael Permit Type: Roof Inspection Type: Final Roof Owner Work Classification: Fiat i Job Address:1490 NE 101 Street Miami Shoresi FL 33138=2613 Phone Number (863)557-7625 Parcel Number 1132050350030 Project: <NONE> Contractor. OCEAN BLUE CONTRACTORS INC Phone:(305)234-6065 Building;Depikinent Comments NEW ROOF GAF/HYDRO STOP PREMIUM COAT n ractio Passed dornments WATERPROOFING SYSTEM INSPECTOR COMMENTS False Inspector Cofriments Massed CREATED AS REINSPECTION FOR RVSP-295619. PLEASE CHECK WHITE PERMIT BOX Failed Correction Needed Re-Inspection Fee No Additional lnspeciions can be scheduled until re•insoctionfee is paid April 18,2018 For Inspections please call:(305)762-4949 I Page 211 of 25 f f FLORIDA INTERNATIONAL' +� ENGINEERING&TESTING LAE; INSIC}£•INNOVATION•1\aUs"sirS 104 6175 NW 167Th Street,Suite G20,Miami, FL 33015 , Ph:305-378-1991 Fax:305-378-1997 I Apr1 IQ, 2018 Dogr Building Department Oficial: f This letter is issued to inform you that; Florida International Engineering, Inc, has been retained owner's representative of the property;to perform a Flood Test over the concrete. Our agreement with the client was to assure testing and inspection of the integrity of the Hydro-Stop Premium Coat Waterproofing System and. verify whether the system is Ieak proof. Representatives of Florida International Engineering,Inc perfcirmed the testing at the referenced site. SITE SPECIFIC INFORMATION JnbAddrerrr 1490 NE 10ISt.,Miami Shores,FL Areas ofobservafion At Deck levels abeve the deck] Permit Number. RF-1-18-136 ;Areas of observation IDirectly below below the deck: Date Tested. 419118-4/10/18 System Manufacturer. GAF(Hydro-Stop) Temperature.*, 790 Weather: Sunny-clear accessible areas t7f , Humidity., '77.00% Nope an 'Time ofDay- 16:50 AM& 1:15 PM Start of Test Deck-Type: Structural Concrete 1VOA: 16-0308.01(Non-insulaled) SystemApplied Primer Barrier, Foundation,Fabric,Top coats f METHQDULUG k,AND►RESULTS C'ontainment,Ass mbly 2 x 6 caulked/sealed Deficiencies found in,waterproofing membiones Multi-decks A pprox.:4,500 SF and ashin s(ifan None Area: total Hose type usedforfilling-TestArea Regular garden hose Monitoring of Critical items durhig fiiCCing of test Direction-of water OK. ares Comments:, Water level in separate pan. 1 Minimum Depth: 3" Maximum Depth': 4-112" Observation of Test.-' M Containment'in good condition.No leaks observed. Locations ofL'eaks(if any) None Locations.and method of repairs( any) None Duration,of Test interval: >24 Hours Conclusion;, I No evidence of leaking,blistering or-any other adverse conditions. 'To the best of my knowledge and ability, this report represents an accurate appraisal of the present condition "of the system, based upon careful evaluation of observed conditions to the extent;reasonably possible. Florida International Engineering, tnc.,,appreciates the opportunity to.have been of service and look forward to assisting you in' any way possible. If you have any questions or comments concerning the report, or if we may be of further assistance,please contact us at your earliest,convenience @(305)378=1991. Respectfully Submitted•." x rr a"-'�1� •�.,,�L.''1>....'S._.„,�'�.a 3,�fs"k'"G.L.. �. � �3 VMlIVenk4egaw P .F.- r r Permit No, RF-1-18-136 Miami Shores Village Permit Type:Roof 10050 N.E.2nd Avenue NE Pen ' Work Classification:Flat 1� Miami Shores,FL 33138 0000 Permit Status:APPROVED yam` Phone: (305)795-2204 FL°R`DA . Issue Date; R/2018 Expiration: Project Address Parcel Number Applicant 1490 NE 101 Street 1132050350030 LUMA SHORES LLC Miami Shores, FL 33138-2613 Block: Lot: , Owner Information Address Phone Cell LUMA SHORES LLC 3128 DOWNS COVE Road (863)557-7629 WINDERMERE FL 34786- 3128 DOWNS COVE Road i WINDERMERE FL 34786- Contractor(s) Phone Cell Phone Valuation: $41,671.20 OCEAN BLUE CONTRACTORS INC (305)234-6065 Total Sq Feet: 4500 Type of Work:Re Roof Available Inspections: Additional Info:NEW ROOF GAF/HYDRO STOP PREMIUM C Inspection Type: Classification:Residential Tin Cap Scanning:3 Final Roof Roof in Progress Renailing Affidavit Review Roof Review Roof, Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $25.20 Invoice# RF-1-18-66156 DBPR Fee $5.25 02/07/2018 Check#:2076 $384.95 $50.00 DCA Fee $3.50 Education Surcharge $8.40 01/18/2018 Check#:2060 $50.00 $0.00 Permit Fee-New Roof $350.00 Scanning Fee $9.00 Technology Fee $33.60 Total: $434:95 i In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all th going information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore uthorize the above-named contractor to do the work stated. February 07, 2018 Authorized Si tur=OwnerApplicant / Contractor / Agent Date Buildiepaopy February 07,2018 1 z� 2��f- �� S� L Y►r �' ) R rCJ Miami Shores Village RECEIVED JAN 18•, Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 v - Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 v BUILDING Master Permit No.RC-11-15-2844 PERMIT APPLICATION Sub Permit No.T-r— I r— 000 i` ❑BUILDING ❑ ELECTRIC N ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL j ❑PLUMBING MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1490 NE 101 Street City: Miami Shores County: Miami Dade zip: Folio/Parcel#: 11_3aps- 03s— 0030 Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder):LUma Shores LIC. C/O Marc Allegre Phone#:863-557-7629 Address: 3128 Downs Cove Road City. Windermere state: FL Zip: 34786 Tenant/Lessee_Name: Phone#: Email: mallegre@me.com CONTRACTOR:Company Name: DGW Not, lJ�'ll,�� Phone4�1a 14-065, Address: 30 cSW luP TeMINC-C—i City: �"ti!i�Wll State:' Zip: 331 Qualifier Name:jN!tA%'—:.tc' Phone f, X3`4- (DOraS` State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer:vdut Phonef.-OmOi sic • WS-0 Address: City: State: Zip: Value of Work for this Permit:$_ �r /(� Square/Linear Footage of Work: 500 Type of Work: ❑ Addition F-1Alteration ((P New ElRR1epnair/Replace ❑ Demolition Description of Work: h[EW -��� L� �tTY � ��•`i JNA W Specify color o,color thru tile: Aj Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ G' TOTAL FEE NOW DUE$ �J (Revised02/24/2014) 4 Bonding Company's Name(if applicable) Bonding Company's Address +' City State Zip Mortgage Lender's Name(if applicable) fJ A, Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or'installation has o commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... 4 OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. { "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature NER or AGENT CONTRACTOR The fofegoing instrument was acknowledged before me this The foregoing instrument was acknowledged beforemethis day of�-44N ' 20 (7 by 1"; day of (1/ 20 `7 by HAkc, tAknoee-:' who is personally known to C*4*t 69*k- W— '� who is personally known to me or.who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: { Sign: Sign: Print: Print: Seal: slier RYREBECCpNOGUES Seal: MY COMMISSION#GG 150292 EMILY RE9ECESCA NOGIJ 't= EXPIRES:0 21.2021 .! ,_ 150292 q Pubrc Unden+rK+R x COA1M13SlON#GG 'roi o.,.• BywlOd nri NotxtY OkPIRES:O&,ftr 21.2021 �. P,dGc Under APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) r� k Miami. hares Villa e� ", pnIm 'Bultding Department 10050 N.E.2nd Avenue { �'toRiv Miami ShoreIF„ lorida 33138 Tet305} 795:2204' Foix: (305) 756:$972 I f' OWNERS'S AFFIDAVIT OF EXEMPTION i ROOF TO WALL CONNECTION HURRICANE-MITiGATION.RETKCiriT FOR EXISTING,SITE BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES i PERSUANT TO SECTI6N'558.844 F.S. I To: Miami Shores lllage Building Department. Date;. 10050'NE 26d Ave J Miami Shores,.Fl 33138.; 1 f Re. Owner's•Name: NNW, • Property Address: 40 RoofingPermit'Number:, Dear Building Official; l . . :certify that f:°arn no#'required;#o retrofit the roof tb wall corinectioris of my building because: a Thejust valuation for#he'structure"for purpose of'ad valorem.taxa#Ion%is less thari'$300 000.00. Please attach proof.of ad val em taxation: The building was;constructed in ctampllance`wi#h.the provisions:of the,Florida Building Code.(t=BC)or wi#ti the provisions of 1994 edition;of the South Florida Building Code(1994 SFBC); i Signature r Print Name State ofd Florida i County of Dade the undersigned,being"flie first duly sworn;deposes and says,iat:he/she is fhe.owner for the above property mentioned. Swom"to,atid subscribed before me this iR'�,`' �day of '"•t EMILY REBECCA NOGUES Notary Public,'Sake'af Florida of Larr�e _ M'COMMISSION#GG 150232 1 :7...... a. d EXPIRES:October 21,20211 t R n 'Bonded ltxu NataryPublic Undvrvritors • When the tus!vatuetioreof the structure for p of ad:vadorW1,ax&tioli Is aqu'I to or more ttlan`$300,006.0©;and the'6u0dirlg was:;ilot constructed with SBC nar a 1994' SFBG_Then you must provide a,bui,iding application fmm'a General Contractor'*the Roof t6walt connection Eiurrtcane'6iitigation, Revised on:5121t2009 '[M r wtAi CERTIFICATE OF ACHIEVEMENT F e • f 7 - x This certifies that ,.. � � r Paul Jan.er F CCC47137 Ocean Contractor Grm,@ rr�{t Ifl t-./ Successfully completed "101 Liquid-Applied Roofing" training event provided by GAF. vb� r .s_1) r r' November 171h2016 -;Mi±ami, FL This certificate is valid for 1-year from the above date _ Daniel Pena Todd Reitz . LIQUID-APPLIED Technical Sales Representative Regional Director GAF Liquid-Applied Division GAF Liquid-Applied Division .�. Property Search Application - Miami-Dade County Page 1 of 1 mERT"' jr APPRAn ISEROFF"Ilk OFTHE PROP yo Summary Report Generated On: 1/9/2018 Property Information Folio: 11-3205-035-0030 Property Address: 1490 SNE 101 ST Miami Shores,FL 33138-2613 Owner LUMA SHORES LLC Mailing Address 3128 DOWNS COVE RD WINDERMERE,FL 34786 USA - PA Primary Zone 1600 SGL FAMILY-3501-4000 SQ Primary Land Use 0081 VACANT RESIDENTIAL: VACANTLAND Beds/Baths/Half 0/0/0 Floors 0 Living Units 0 Actual Area 0 Sq.Ft Living Area 0 Sq.Ft i Adjusted Area 0 Sq.Ft Taxable Value Information t Lot Size 15,732 Sq.Ft 2017 2015 Year Built 0I County Assessment Information Exemption Value $0 $0 $0 Year 2017 2016 2015 Taxable Value $2,004,886 $2,004,886 $770,000 Land Value $2,004,886 $2,004,886 $1,856,376 School Board Building Value $0 $0 $0 Exemption Value $0 1 $0 $0 XF Value $0 $0 $0 Taxable Value $2,004,886 $2,004,886 $1,856,376 ._..-..._.__._.-......._____......... .��.. Market Value $2,004,886 $2,004,886 $1,856,376 city Assessed Value $2,004,886 $2,004,886 $770,000 Exemption Value $0 I $0 $0 Taxable Value $2,004,886 $2,004,886 $770,000 Benefits Information Regional Benefit Type 2017 2016 2015 Exemption Value $0 $0 $0 Non-Homestead Cap Assessment Reduction $1,086;376 Taxable Value $2,004,886 $2,004,886 $770,000 Note:Not all benefits are applicable to all Taxable Values(i.e.County, School Board,City,Regional). Sales Information Previous Sale Price OR Book-Page Qualification Description Short Legal Description 02/25/2015 $2,300,000 29524-3873 Qual by exam of deed DUNNINGS WATERWAY 09/03/2013 $825,000 28827-3213 Qual by exam of deed PB3 -46B LOT 3 LK LI 1 12/01/2005 $2,505,000 24142-1706 Sales which are qualified LOT SIZE 15732 SQ FT COC 24142-1706 12 2005 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at hfp://www.miamidade.gov/info/disclaimer.asp Version: a http://www.miamidade.gov/propertysearch/ 1/9/2018 I i✓ i OCEAN CONTRACTORS GROUP LLC Estimate 199 10 Coral Sea Road ' Cutler Bay, Florida 33157 Date Estimate# + i 8/30/2017 17-0836-R Name/Address Luma Shores LLC Attn:Marc H Allegre r 3128 Downs Cove Rd. Windermere,Fl 34786 Project 1490 NE 101 St-G... Description Qty Rate Total r Residential Waterproofing Services to property 1490 NE 101 Street Miami Shores,Florida 33138 r a SCOPE OF WORK: Residential GAF/Hydro Stop Premium Coat Waterproofing- Color:White over concrete sloped Roof&Traffic Decking. Cost...(*) 1 41,671.20 41,671.20 (*)NOTE: PRICE IS ONLY GOOD UNTIL 10/31/2017-IT IS SUBJECT TO CHANGE WITHOUT NOTICE. I Payment Terms:30%Deposit + 40%Upon Mat Loading 20%In-progress 10%Final a Warranty: 10-Years Renewable Manufacturer Gtd. EXCLUSIONS: No HOA Fees;Security;Boom/Crane fees, Change in Contractors fees;Permit fees,engineering fees,electrical, plumbing,siding,skylights,chimney, stucco,painting,gutters, landscape and any and all corrections to be made to the roofing surface incorrectly made by other tradesmen/contractors. NOTE: 1. General Contractor shall provide the Roofing Contractor: A. with access and stagging area B. any and all roof penetration completed prior to roof commencement,as required 2. General Contractor or Plumbing Contractor shall provide the Roofing Contractor. A. any and all Lead Soil Stack/Lead roof drain and hardware, as required + Estimate shall be void if not accepted within 10 days of the date shown. Total Page 1 a "SEAN COMTRACTOWGROUP I t er Ba* 116ch_3157, 1 i aye f � ,Y� 3i17 1 ��17•-�3�i-�i, Nan*l Addl6ss;, Uma ShoI C, Ann--,,Mait H 3118 DOirm Gave Rei: 'Wlamna ,'Ft 34786 r 1 i r_. 140 M9`1 t11 St r: 3 CSI I� C�t�titWchaui6lconAwr r rF a o bay,mW all I(la,5'C, a;;;� tms F# 123 F 1 s I ^�.�etlCf�1�gT#t3:tCtiig"51i>311 pl�� 1Zt�lf�l��.Q3'ft��tEth':E o a .: .. 1l1oC CLnE' i txlCtCt1 SOT to mof ` • ..._�..• _ v.., .. ._•_ __. c ,x _r :.:,«ate, i 9 ba is ' � E e " �:Y n ' ., •. �:�'awry,,. ...._. � fn � S F.atitiatr shaH beVoid iti at dried%ithin 10 hays of t1se date A4", d r • t � r + f OCEAN CONTRACTORS GROUP LLC Estimate 19910 Coral Sea Road Cutler Bay, Florida 33157 bate Estimate# 8/30/2017 17-0836-R Name/Address Luma Shores LLC Attn:Marc H Allegre 3128 Downs Cove Rd. Windermere,F134786 Project 1490 NE 101 St-G... Description Qty Rate Total 3. General Contractor or Mechanical Contractor shall provide the Roofing Contractor. A. any and all stands/base and/or curbs,as required. 4.General Contractor shall provide the Roofing Contractor A. Any and all wood blocking or concrete curb blocking completed prior to roof commencement,as required i a Estimate shall be void if not accepted within 10 days of the date shown. Total $4,,6,,.20 Page 2 C � CERTIFICATE OF LIABILITY INSURANCE DATE(MIwDDnYYY) 01/05/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). I PRODUCER CONTACT NAME: PHONE A/C,No,Ext): 800 277-1620 X4800 FAX A/C,No): 727 797-0704 FrankCrum Insurance Agency,Inc. E-MAILADDRESS: I 100 South Missouri Avenue INSURERS AFFORDING COVERAGE NAIC# Clearwater,FL 33756 INSURER A: Frank Winston Crum Insurance Company 11600 INSURED INSURER B: INSURER C: I" FrankCrum UC/F Ocean Blue Contractors,Inc INSURER D: 100 South Missouri Avenue INSURER E: Clearwater FL 33756 INSURER F: COVERAGES CERTIFICATE NUMBER: 467769 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSRD WVD j (MM/DDNYYY) (MMIDDIYYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE OCCUR DAMAGETO RENTED $k PREMISES Es ED MED EXP(Any one Person) $ PERSONAL b ADV INJURY $ P L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S POLICY O PROJECT aLOC PRODUCTS-COMP/OP AGG $ , OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accide rt ANY AUTO BODILY INJURY Per erson $ OWNED AUTOS SCHEDULED ONLY AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ ONLY AUTOS ONLY Per accident $ UMBRELLA UAB OCCUR EACH OCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTIONS L $ WORKERS COMPENSATION AND WC201800000 01/01/2018 01/01/2019 X PER STATUTE OR A EMPLOYERS'LIABILITY Y/N ER ANY PROPRIETORIPARTNERIEXECUTIVE OFFICERIMEMBER EXCLUDED? Q N/A E.L.EACH ACCIDENT $1,000,000 (Mandatory In NH) 4 Ifyes,describe under E.L.DISEASE-EA EMPLOYEE $1000000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 I Y. I DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required) Effective 11/28/2016,coverage is for 100%of the employees of FrankCrum leased to Ocean Blue Contractors,Inc(Client)for_whom the client is reporting hours to FrankCrum.Coverage is not extended to statutory employees. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE VWLL BE DELIVERED IN ACCORDANCE VWTH THE POLICY PROVISIONS. Village of Miami Shores AUTHORIZED REP SENTATIVE 9825 NE 7th Avenue Miami Shores,FL 33138 r,s ©1988-2016 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD I CERTIFICATE OF LIABILITY INSURANCE ; DATE(MM/DD/YYYY) 01/09/18 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT'AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES i BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARTA ALONSO NAME: Florida Bankers Insurance PHONE (305)266-6493 N No (305)262-0679 6874 SW 8 ST E-MDRLE . marta@floridabankersinsurance.com Miami,FL 33144 PRODUCER CUSTOMER D 1k Phone (305)266-6493 Fax (305)262-0679 NSURER(S)AFFORDING COVERAGE NAILS INSURED INSURERA: UNITED SPECIALTY INSURANCE CMPANY OCEAN BLUE CONTRACTORS INC INSURER B: 7930 SW 126 TERR INSURER c: EVASTON INSURANCE COMPANY PINECREST,FL.33156 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:. REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. i�TR TYPE OF INSURANCE INSR D POLICY NUMBER (MWDDAIYM (MWOD/YYYY) UMTrS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000.00 7. a COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) I $ 100,000.00 ❑ E] CLAIMS-MADEe OCCUR DCG0410801 MED EXP(Arty one person) $ 5'000.00 A ❑ N N 11/29/2017 11/29/2018 PERSONAL&ADV INJURY $ 1,000,000.00 ❑ GENERAL AGGREGATE S 2,000,000.00 GEML AGGREGATE LIMIT APPLIES PER PRODUCTS-COMPIOP AGG $ 2,000,000.00 e POLICY ❑ PRO- ❑ LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) I ❑ ANY AUTO BODILY INJURYPer ❑ ALL OWNED AUTOS INJURY( person))I $BODILY INJURY(Per accident) $ ❑ SCHEDULED AUTOS PROPERTY DAMAGE I ❑ tARED AUTOS (Per accident) $ ❑ NON-OWNED AUTOS $ ❑ $ . a UMBRELLA LIAB ❑ OCCUR EACH OCCURRENCE $ 5,000,000.00 C ❑ EXCESS LIAB ❑ CLAIMS-MADE N N EZXS1007777 11/29/2016 11/29/2017 AGGREGATE $ 5,000,000.00 ❑ DEDUCTIBLE $ ❑ RETENTION $ _ $ WORKERS COMPENSATION WC STATLL OTK AND EMPLOYERS'LIABILITY Y I ANY PROPRIETOR/PARTNER/EXECUTIVEN A EL EACH ACCIDENT ' $ OFFICER/MEMBER EXCLUDED? (Mandatory in NN) EL DISEASE-EA EMPLOYEE$ IiyS,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) PROJECT ADDRESS: 1490 NE 101 STREET MIAMI SHORES,FL 33138 1 ROOFING I ) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN MIAMI SHORES VILLAGE ACCORDANCE WITH THE POLICY PROVISIONS. t 9825 NE 7TH AVE MIAMI SHORES,FL 33138 AUTHOR12ED REPRESENTATIVE ®1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09)OF The ACORD name and logo are registei red marks of ACORD t � .Vu'Julu y.r.,,-t..,.,,. �, a.�,�,n"►,"a"","•`°td.�n .` ��.,� `af ;.1--' z.ti 'L,,. _.._..4:..,. .,,{�,.�,�a'`Y�+k �,f. t ace&1 B tL�, i Marnl� DadeldountyxStateof'F_Icrla . � � '�' '�,� ,' t ��THIS'"!^s NOTrA BILL`❑0 TJOT-PAY. � '" � .a. • r a: � � �j�` z1 -I 62486', "11�6SS,NAMEfLOCA17pt�ht# *+-� + IEiPT Nss• #m? ^� Tt Ii, a t �� OCEAN$lUE CONTRACTORSINC M REMEWY E�CP�RES 76305 i2��ER .a 4 SEP`�'EMBEIR,16 , 0'18 ,} FIIVECREST,.FL 33156 ; must be tlispl*ed% place fbu;&iness' ` Pu31- tsua"tto County !i Chap6r 8A-Art.9 si 10, t27 t r Y LI ri� b{''j r k'•-w. d a. OWNER,' a ,f SEC.TYPE OP BUSINESS �k. y M .-a i { OCEAN BLUE CONTRACTORS INC. E 196 SPECiAUOYtYIWING CONTAAL7611 PAYMENT RECEIvBd '*V6 MAR' ON" f � [CCC47137 1?• '' ABY TAX CdLLECTOR Wotker(s).. Z »" ` *'. $4S 00 Q V24/201t ,r. ,� r ` Th" loceiBnsinessTaxircaipt L,;;tmnHnns"i 1{ �e4 '-`iai 1a ifi . µ c + 1110hmt er a certification of the Iwber'a siificaM mto d beiut�aemssB Haider must come Receipt is not a 1lcerue f w ! ` � Zortwngavemmsaw", utatoryiayisai requiramentswhich a Ph! enygovemmont l; PPB to tbabj mesa, ._�t�TtreRnapTNO;aboveauttCbedutla " x"tr r + �, P �6j ill coeunerccal veliidbs lNi nR-OsAd Code Set 8e-MI, �' �` For moromfonnatior,vrttvmiam�dedeoavhexc6tt�H� * .. , � d005004 � =1,- 1 k-'!'�ft{�� r _ �;... y::,::,.�.r •tt.,. ,` �fv ._... _r,,,„�,,.,-.ri,.. y .w T3,.,�,�„�`` `' 1+” y`_.,,s'•' �^.. _r9''"'t..-<w� •.J�=-t� �}�: „�..M1i. F�: < 4 L mess -Ta-rRc6ceipt # an1 Dade.Cdunty;S'af Flarlda 4,, s A�=THIS IS NOTA BILL=gdNigPAY •+ *, + i { Ssn a •- � _ �. ,. i suslNEss'iuAn7lEr`tdcAT�+aN. :wa #3cElarwr " *•. a. I l ' vC v aLuE CoN7rRA ro s;>iNc FtENEW =SEPTEMBER 30' 2018. 4 ,7930 SV#i.i26 TER, 74Oi 32" , , ,MIAI�AI FL 43156 Must be dispisyed et pla a-busim, t >.- Y ., A' �" 5 Pursuarn } a,�„ ,� { ,to�trur�ty p 9&1!) r � ! �F 77 OWNER- p rr ' SEC>'TYPE OF BUSINESS" � S �,w y �" �� �a " PAYILISpiT REdg, p� OCEAN BLUE CONTRACTORS iNC C/,O I tom, (�iLDING CONTRACTOR- 483 CdLLECTOA i ( ��, ` w.r ���+ L' -CG'C16U7 BV TAX + �. Worker(s).' ,. � '¢t a1, r ��$45.00'Q924/20?17 y 1 xe s ECHECK!17` 190712 t t Thin Local Business Tad Racef�! r I ! g n oNY coMirma payment ottke Locat Bu:nresa Tax.The Rooe fa aot a license, r , . ,•E r t Pertai4�atacettHicatio"Othe olders eliRcetions to"dobbsiness.Holder mosteom , ot'aat Quern" �Ygov®mmenfal` � g r meata�ropu'tetary sews en roquitements wHlab apply to the Witness '' wGh a t I r 1 ,. J c-, i RECO"No.One nnisthi displayed orcail Commercial vehicias`=Miami=pada Code Sec,.> `g ss nY For koro iofirot! rt.volt . ,. .. -.,i•.....r � -C°r^�m- � ,+ r #.�"�-_.. �.. •k...riw?^�r^,!„w;.%"+ht`iY�e=� � 'j,�....N..:�`�` �3k`r; �' i 1 ~ I � 7 I V t I " =KEN LAWSON;SECRETARY-`"`— 'RICK SCOTT GOVERNOR .xpSTAMOFFL .R, IDe`A 1.w—f yJ wW "yy . OL ,� Ur TCi N DE = T RAN � TIOINbUStRYhLICENSiNG BOARDCONSTRC , -� ,'.��-.!�" .m^+!�� "z'� '�;"^°�' +E±+iclw rte"" ,da .:r.t:x_. ��'"" �'-�• •vy'�W�`+x.. "'1NF.,S�r£ ,��_,4.�0. �"�: _ '9'�t-�?w, 1 .� arc ^�` °' s * 4 . * '"'"y4 w A• '@ '"`t.-4; l-j f 1 ". .. .. 74"'4 ,.tN` =•,,. ,., ^tag: 9y.yi *«.. y '" ';' s WA The`RODFING CfJNTRACTOR °"' ;C �a"s q t k y L` Named below IS CRTIFIEb ,, ,,k �� . ' ? iJnder the pr�i►Visions o1Ctrapter°4S9 fS��"�� f xiratbn date:''AC1G 31•,;�d18 .. .� " , ,, „ia-; pd,•��'';r ...*pf� ,ir' �`>!'��+es�".>.`°'"`"" a.�� ,>, F� �,y'rr 1 �kqm,.. + ,�`l �. r,i' ■ p.. i;'� NT oCEAteft:U�CQ ¢- w°,a;',•: > 7905',,,TUIs Tr. ! 4f -} *4, " ECREST ,,, _; �.. w .x ��� �? s �A ' 15SlJED:' 0$J91l201Ei . DISPLAY AS`REQUIRED B1!LAW, W.Ile , SE #-'11608110002109 •y4 n _ a A'. ° " ... wer..,-•.ter f. '1 °. ,RICK SCOTT GOVERNOR KEN Li4WSON,-SECRETARY x, �- .... � -h,....,r.�.,.,.�...�..�.......,�.�.�..4s�,....�..�--•�^-• :a,,�.,y..,...............�.-.�..-.,�,-.--�-.-��-.>..�..:,�-,..,>.,, mss,.,.,,»«,- ,Ms,.... ,.,�. i 'STATE FLORIDA ', .- y•�a �., ' �^�DEPARTMENT,t3F BU "IN,E, NO PRO FE SSIONAL`IREGULATJONf CONSTRUCTION INDUSTRY=LICENSING BOARO�: ,•'� w IL i � ,�'.,:;�,„;,.- neap~`� L.+. �',._w �^{' .X .. ^�.,' ..+•c•"wr �:..,.,.'�'-x �,''�, , Aeppyy "* ° IN a ed eolr The:GEN� .CNT2ATQR + }� fa'a fChapteA✓1t�, ' yM.R".+k...K?'�hwM�(,e w A �� '-IyM,. �`i.a. y� 's� 'Vs«^6.Ott.6i.D.yW�a. +x �� Under theP,prqV)slops of r 489�FS l *xp ahonX datAUG',3,12018 SwF^;JJ-"��, "`� ''�'"-aN._��r.-eta-x'�„""* :.a4 A`�'""'�,yrv�"•«-s.,, ,+��k;,M1 k�.,� ��,,�.. 5���^���`'a '�.�. 't4k'.a� �� ,�+,ti - + �. M � v Z. ,gx•'4,.r`'-F.n+"e> "'.x.W, 1. '�6, '"'�. ,i, at< s=� *�'>6..irn•!' 9 At. ..d � Y ��Y �`� F' q,'�+� .d. n•o � a..na'w''5�+.� �� "�''` e��gs... '4 'ti` � ■ �� ■ `{,. S JY;. ISQG-DA 7 nSW Tt i A � �, n j ;.� P NECF2ESTr�'°�, F� X56 � ` � ,� ��,,, 1 ,• •' �.,.„ a�y�(R., cam. �"'t"� _ a,,;z ti !�` i -fssoE,D ,08(;1112016: DISPLAYASREQUIREI7°BY LAW SEQ#€ L1608110002310. tv v� � .4 .,p,9 x •r� � � �„ n E i n c w Property Search Application- Miami-Dade County Page 1 of 1 WE Aft OFFICk UF THE PROPERTY APPRAISER Summary Report Generated On: 1/18/2018 Property Information Folio: 11-3205-035-0030 Property Address: 1490 NE 101 ST Miami Shores,FL 33138-2613 ' - Owner LUMA SHORES LLC Mailing Address 3128 DOWNS COVE RD ' A WINDERMERE,FL 34786 USA PA Prima Zone- 1600 SGL FAMILY-3501-4000 SQ s, Primary Primary Land Use 0081 VACANT RESIDENTIAL: ' :•' VACANTLAND ` Beds/Baths I Half 0/0/0 - Floors 0 ,' s Living Units 0 Actual'Area 0 Sq.Ft Living Area 0 Sq.Ft Adjusted Area 0 Sq.Ft Taxable Value Information Lot Size 15,732 Sq.Ft 2017 2016 2015 Year Built 0 ----- County Assessment Information Exemption Value $0 $0 $0 Year ' 2017 2016 2015 Taxable Value 1 $2,004,886 $21004,886 $770,000 Land Value $2,004,886 $2,004,886 $1,856,376 School Board Building Value $0 $0 $0 Exemption Value $0 $0 i $0 XF Value $0 $0 $0 Taxable Value 1 $2,004,886 $2;004,886 $1,856,376 Market Value $2,004,886 $2,004,886 $1,856,376 City Assessed Value $2,004,886 $2,004,886 $770,000 Exemption Value $0 $0 $0 Taxable Value 1 $2,004,886 $2,004,886 $770,000 Benefits Information Regional Benefit Type 2017 2016 2015 Exemption Value $0 $0 $0 Non-Homestead Cap Assessment Reduction $1,086,376 Taxable Value $2,004,886 $2,004,886 $770,000 Note: Not all benefits are applicable to all Taxable Values(i.e.County, School Board,City, Regional). Sales Information Previous Sale Price OR Book-Page Qualification Description Short Legal Description 02/25/2015 $2,300,000 29524-3873 Qdal by exam of deed DUNNINGS WATERWAY 09/03/2013 $825,000 28827-3213 Qual by exam of deed PB 114146 12/01/2005 $2,505,000 24142-1706 Sales which are qualified LOT 3 BLK 1 LOT SIZE 15732 SQ FT COC 24142-1706 12 2005 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp Version: f http://www.miamidade.gov/propertysearch/ 1/18/2018 2018 FLORIDA LIMITED LIABILITY COMPANY ANNUAL REPORT FILED DOCUMENT#L15000023795 Jan 13, 2018 Entity Name: LUMA SHORES LLC. Secretary of State Current Principal Place of Business: CC1213326330 964 LAGO MAR LN BOCA RATON, FL 33431 Current Mailing Address: 964 LAGO MAR LN BOCA RATON, FL 33431 US FEI Number: 47-3064918 Certificate of Status Desired: No Name and Address of Current Registered Agent: ALLEGRE,MARC 964 LAGO MAR LN BOCA RATON,FL 33431 US The above named entity submits this statement for the purpose of changing its registered office or registered agent,or both,in the State of Florida. SIGNATURE: Electronic Signature of Registered Agent Date Authorized Person(s) Detail Title MGR Title MGR Name ALLEGRE,MARC H Name ALLEGRE,LUCILLE S Address 964 LAGO MAR LN Address 964 LAGO MAR LN City-State-Zip: BOCA RATON FL 33431 City-State-Zip: BOCA RATON FL 33431 v 4 i Y 1 hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath;that I am a managing member or manager of the limited liability company or the receiver or trustee empowered to execute this report as required by Chapter 605,Florida'Statutes;and that my name appears above,or on an attachment with all other like empowered. SIGNATURE:MARC ALLEGRE MANAGER 01/13/2018 `Electronic Signature of Signing Authorized Person(s)Detail Date RECEIVED , 1 JAN 181017 ROOF ASSEMBLIES-A D RIES, ' Fto� a,8u 1 1 Code Sth Edition 2014 2 0 d High,Velocity H'Ufftan@ Zonevniform Permit Apptication;Too�.� O s It— (7 " Section A(Gelieri.informs#ion) , f Master Permit Na. �y �' ?i�'�� �o<, Pro,c_ss No.i 90 ! I Contractor's Name V 5 C,�'v t�i�. ��G O� 6 Job Address l �_ Hi AMS ROOF CATEGORY KLow'Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adiiesive,Set Tiles- C] i4sphattic Shingles ❑ Metal PaneitShingles: ❑ Wood Shingles/S at�s l E3 Prescriptive BUR-RAS 150' ! t ROOF TYPE New'roof ❑ Repair O' Maintenance ❑ Rerodfing •••• p` 'Reeoye ns .1 t ROOF SYSTEM INFORMATION ••• •• 909616 Low SlopeRoof Area SF) " Steep Sloped RooAREA(SSFTotal(SFP :....1 1• ...:.. .. . .... Sectidn 8(Roof Piaci) • Sketch Hoof Plan:Illustrate all levels and sections,,roof•drains,scuppers,overflow scupp®rs and ave f iw drains.iMciude dimen-.1. cions of sections and levels dearly identify dimensions of elevated.pressure zones and location Df p9raoets: • 0' , • ...... 71 :L __. I 1 d t 1 ! . . . .. . it t FLORIDA"BUILDING CODE—BUILDING,Sift EOM6N{2014) 15.37: wifft M.11 Cap mento,or ilr$e r by,ICC(ALL RI(rHTS RFSEi1V FD):gxessed by Elieur Palpeio on Jun$.?flT S 19:32:12 AM pursoenl W Licenst, Agt�Cn?et�t.No furthgr teproductioas wthonmd. a t 1/5/2018 Rewards&Offers i Dunkin'Donuts 4 r---------------------------------------------------------------------------------------------------------:-----------------------------------t -DD PERKSTEIE BEV GE REWARD E !r f ± Congrats on earning a Free Beverage Reward! This reward is good for one free"beverage of any size excludes cooler beverages). �•• ❑ 4 t �rt t t y 8836795143684 i Expires:-04/05/2018 l y7 1 y t Coupon must be presented at time of order.-Excludes cooler beverages, gallons and Box 0'Joe(42 . Almond j Milk and Turbo shots maybe subject to additional charge. Shop must retain couponrNo substitutions ;•P••; allowed. No cash refunds. Void if copied or transferred. Consumer must pay applcabl.tax. Qeothenly a:•.�•; participating Dunkin' Donuts location`s. May not be combined with any other, couiw.-Ascount ar •• promotion; and is limited to one-time use. Cash redemption value 1/20 of 1 cent. Lqterpet distrjbution �•..; strictly prohibited. • PRINT REWARD •••:•• •••••� �,. L---------------------------------------------------- • • k w https://www.dunkindonuts.com/en/account/perks-rewards 3/3 ROOF ASSEMBLIES-AND�ROOFTtJP STRUCTURES Florida Building bode 5th Edition(2014) 1 High-Velocity Hurricane Zane"Uniform-,P ermit,gpplication Ftbr th. 1 1 { 1 Section C'(Low Stops Application) =T `P a of f Ing ate 1 Fill in specific roof asserribiy components and identify orr 1 11 manufacturer Surfacing 1 (if a component".is not used,ident;fy as"NA") Fastener Spacing fvr 4nchorl8ase Sheet Attachment; V ' System Manufactures', 1 Field: oc @ La , Rj fs4@�_,_-'oc 1 II(I�- Perimeter: oc 1 Product Approval Na.:1(Q �JOD• Z _ _' P.#ob ,Q 1 1 r 1 .Design )nd`Pressures,From RAS 128 or,Galculations: Comer:_"oc @ Lap,#,, ows C� 1 1 01' . 0 P2:. I�!I , !� Number of Fasteners Per insulatt 0 Board, __—___�.P3.. 1 i Field �' Perimeter: Iii " Comer 1• Mak,peslgn'Pressure,from the spegifiproduct i, opprovol'system. Q ••• 1 Illustrate Componentshloted and l?etails as AppSiribi®' .�.... {, Deck: Woodblocking,.Gutter; Edge Ternlia�ttior%Stripping Flashing, 1 • Type:- , � �.�t,P Continuous Cleat,Cant.Strip;BaV.Flagyng,Co�A�}tT , .. Coping,Etc. • 1 i_(1 indicate: Mean,Roof"Height,:Para�t*kteight,.HVigtit:Qf Base •••• Gauge/fhicliriess _. Flashing, Component Matefia1, Material•Thiciaiess! stener ► Type,Fastener Spacing or SubmitUanufa`ctureis Details-,that � : • Slope .. .. .. ..... ii Comply with RAS 111 an hapter 1V . 1 ,Anchor/Base,Sheet&No.of Ply(s): Ir .• ,� ... ;1 i4nchorBase'Sheet Fasteriet•1Bonding`Material N � ••• 1 _ 0 0 . . • FT' 1 insulation Base Layer:. _. � . I Base Insuiatiori Size'and Thickness:::.�:. C Para Height 1 Base Insulation Fastener/Bonding Mate L 1 1 Top Insulation-Layer:. . . ifi +' Top Insulation'Size and Thickness:: N '1 . .. �'�..... 1 Top Insulation Fastener/BonRoof ding Mat ootti 1 ,1 t,•ro 1.JS( t•'" � _ Base Shtaet(s)`"&No.'of Plym r1 �� 1 1 1 Base'5heet Fno ri" i g Materiae: 1 Ply Sheets)&No.`of PIy(s): � 1iADATtc7l� ��� N �: 1 I Ply Sheet Fastehie/Bondin"°Material. IAAIAKAA Top Ply:Yt twilyy►/► SMS (14%%r, 1 i 1 t t 1 - �yp�y �ianc au FLbRIDA BWLDING CODE.=—'BUILDING;6th'MMON(2'014) .11 Agecment.No Authw t$ 1 COpynBbt ta,or licensed b",TCC(ALL i RIGHTS )2ESERVkD);n=50 by Eltew Palacio on fun 8„2t)i5 IA 32 12 AM pursuant to License; st i i , 1/5/2018 Rewards&Offers I Dunkin'Donuts r--------------------------------------------------------------------------------------------------------------------------- D' ERKSi FREE BEVERAGE REWARD Congratsaon,earning a Free Beverage Rewards=ThWreward its ' good for one free beverage. of;any size Cexciudes`=cooler 'bever`a es 75 �j'i."p..r � 1`•�"'e.'�'.i � ✓NNw'�J-^s `�k �!{1.� 8836795143684 1 P -Expires: 04/05/2018Wilt { Coupon must be presented at•:time of order; Excludes cooler beverages gallons and Box O'Jee(R�pAlmond Milk and Turbo shots may be subject to additional eharg`; Shop�+must retain coupon*qN; substitutions allowed. No cash refunds. Void if copied or`transferred-,Consumer mast pay appli�abletax!0•vod,mly at••••; participating Dunkin' Donuts locations. May not be combir�.qd--with ariy,other c`,oupc2t�,�¢�Scorit og • E. . bin, ,X : promotion; and is limited to one-time use!Cash redemption:valuel/20 of;}ije;rt lrjerget-distrjAuVon ••••;; strictly prohibited. TF • 1V���r R • • PRINT REWARD • , Y, L___________________ • • I � r -case---- --------- { . vh 4'• y ..�`F. x 4 L } + I y https://www.dunkindonuts.com/en/accounVperks-rewards 1/3 r 1 I { CONCRETE ROOF DECK COVER WITH"BARRIERGUARD" SLURRY OVER BARE CONCRETE' PREMIUM COAT SYSTEM: 4 FOUNDATION COAT, FABRIC, FOUNDATION COAT,AND FINISH COAT OVER ENTIRE ROOF FIELD LAP PREMIUM COAT SYSTEM COMPONENTS FROM THE ROOF FIELD OVER EDGE DETAILlo, "(203 mm) - FOUNDATION COAT, 12"(305 mm) •••• FABRIC,AND FOUNDATION COAT • , ... 1 0000. COMPONENTS • • • COVER ENTIRE EXPOSED EDGE '•' •;'..• �,• ••' '.• • ..f ;: .... 400 + ♦. . ; • �• �: '.i .•.•)� • .i .. 0000• 0000• •••••• • • • • • •0:00 0000•• WALL 0 0*9 • • •• -00-0 . • •• • r 1 NOTE: 1.ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE CONDITIONS. METAL THICKNESS,FASTENERS AND LAPPING SHALL BE AS SPECIFIED BY THE ROOF DESIGNER. I 2.REFER TO THE SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS. 3. PREMIUM COAT SYSTEM-FOUNDATION COAT, FABRIC,FOUNDATION COAT,AND FINISH COAT COMPONENTS. 4.PRIMING-REFER TO HYDROSTOP®SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS. { 1. CONCRETE ROOF DECK SYSTEM , DRAWING# HYDROSTOP" , H EDGE DETAIL HS203 vnvw.get.com SCALE ISSUE/REVISION DATE 1 Campus Drive ROOF EDGE Parsippany.NJ SERIES N.T.S. 6-1-16 07054 r ` STANDARD PREMIUM COAT ROOF SYSTEM REINFORCING FABRIC PIPE WRAP 12"(305 mm)x 12"(305 mm) REINFORCING FABRIC OVER PIPE WRAP q:: L_ _,1 { PLAN VIEW fi METAL OR PLASTIC VENT PIPE PENETRATING ROOF MEMBRANE --- STORM COLLAR,IF REQUIRED . 0000 FINISI P.COj4Y COMPONENT OVER*•• ENTIRE4ROOF • • • 0000.. 0000.. ,. 0000. FOUNR91VA COAT,.14'(305 mrg) FABRIC.Qap FOUIPATIQN COAl •'• E z_ COMPOjjFa7s ;••••• 0000. 1O PLACE'A0blZONAI.CAYERS OFO REINFORCING FABRIC AY -- PENEIRQTItN BASE,AS SHOWN '. . . 0 0 000000 0000.. ROOFpEQ146AND INSULATION �••••� SYSTEM* •• • SECTION VIEW '..'.' FOUNDATION COAT, FABRIC, AND FOUNDATION COAT COMPONENTS NOTE: y I 1.THIS DETAIL IS A TYPICAL PENETRATION DETAIL APPLICABLE FOR ALL COLD PIPE PENETRATIONS. FOR HOT'PIPE PENETRATIONS,CONTACT THE MANUFACTURER FOR REQUIREMENTS. , 2.FOR PIPE PENETRATIONS THAT EXCEED 18"(457 mm)ABOVE THE ROOF SURFACE,A STORM COLLAR SHALL BE USED WITH A DRAW BAND AND CAULKING.THE ROOF COATING SHALL EXTEND 8"(203 mm) MINIMUM UP THE PENETRATION SURFACE AS INDICATED IN THIS DETAIL. , 3. PREMIUM COAT SYSTEM-FOUNDATION COAT,FABRIC,FOUNDATION COAT,AND FINISH COAT COMPONENTS.ALL GUTTER SEAMS ARE TREATED WITH FOUNDATION COAT AND 4"(102 mm)OR 6"(152 mm)FABRIC DEPENDING ON PROFILE OF THE GUTTER(CONTACT TECHNICAL SERVICES). , 4. PRIMING-REFER TO HYDROSTOP®SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS. r SYSTEM DRAWING# HYDROSTOP' VENT-PIPE FLASHING DETAIL HS 502 www.gaEcom. SCALE ISSUE/REVISION DATE i Campus Drive ROOF,PENETRATION Parsippany,NJ SERIES N.T.S. 6-1-16 07054 J , 4 ISOMETRIC I � INSTALL APPROPRIATE SEALANT (E.G., POLYURETHANE)AND TOOL TO FACILITATE WATER RUNOFF TERMINATION OF MEMBRANE ' FLASHING WILL VARY SHEET METAL SCUPPER SOLDERED/WELDED;SECURED TO WALL AND DECK OF OPTIONAL WOOD BI OQKING Y • zc' FOUNdA-FiON COAT- FABRIC •• FIN ISH•QOAf-COMPONENT OVER••• ENTIRR0130F, FINISH IN • SPECIFIEDCOLOR• • :•••• FOUNDATIV4COAT,4FABRIC, ••:•• AND F01JlQATION'b0A%• •••i• COMPONE"T.S I • •• 90*000 . • I ••••• w• • •• • • 3 3 ROOF DECK 1 s, is NOTE: SYSTEM DRAWING# HYDROSTOF SCUPPER DETAIL HS; 305 3 w .gafoom SCALE ISSUE/REVISION DATE v 1 Campus Drive WALL&CURB Parsippany,NJ SERIES N.T.S. 6-1-16 07054 t I FINISH COAT FOUNDATION COAT,FABRIC, FOUNDATION COAT TAPERED INSULATION ROOF DRAIN TO BE INSTALLED AS REQUIRED BY MANUFACTURER r I t 0000• • ROOF Q "QWG' i•••• ••••� 0000• ------- 0000 • • • • • 0000•• 0000 • 0000• 00.00• , •• • •0.00 • 0000•• • • • • • • 0000• 0000•• • • • ' 0000• s f i NOTE: 1. ROOFING MEMBRANE SHALL EXTEND UNDER THE ROOF DRAIN COMPRESSION CLAMP RING. 2.ALL DRAIN COMPONENTS SHALL BE MADE OF CAST IRON UNLESS APPROVED BY THE ROOF y MEMBRANE MANUFACTURER TO USE ANOTHER MATERIAL. 3. SLOPE INSULATION TOWARDS DRAIN. 4.PRIMING-REFER TO HYDROSTOPO SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS. SYSTEM I DRAWING# HYDROSTOP" STANDARD ROOF DRAIN DETAIL HS 504 w .gats m - - SCALE ISSUE/REVISION DATE M1 Campus Drive ROOF PENETRATION Parsippany,NJSERIES N.T.S. 6-1-16 07054` .. .. . . . .. .. . . . ... . . . . ... MIAMF[aAC�E ® ••• •: •� •.MIAMI-Dgs�COUNTY • • PIOD[CTC03TROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) :•: • •;•1 l$15 SW.ZCi irwl,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 fNOTICE OF ACCEPTANCE (NOA) ' wwNamvamids00 de ov/economy GAF � � � � �• 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. 1 DESCRIPTION: HydroStop® PremiumCoat® System over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any poftion of the,NOA is dgplayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided't6 the user Wthe manufacturer or-its distributors and shall be available for inspection at the job site at the requesi-:ofxhe Building Official. ; This NOA renews NOA No.13-0204.16 and consists of page`s ll'through l 1. - The submitted documentation was reviewed by Gaspar J R0, gue :,,� u IV r NOA No.: 16-0308.02 FgAM C"E COUNTY Expiration Date: 06/22/18 '� ry Approval Date: 10/27/16 Page 1 of 11 r ••• • • • • ••• • •• ••• •• • • • •• • •• • • • • ••• • Jv• o ��sY c�a a a c � O 4 °c tP Jb x o � e, 0 5 • • • • • • • • • • • • ••• • • • • ••• ROOFING SYSTEM APPROVAL • . . .. .. . . .. . . Category: Roofing • . ... ... .. ... . Sub-Cateaory: Liquid Applied Membrane Deck Tyne: Concrete .. . . . .. ... .. Material: Elastomeric Maximum Design Pressure: -610 psf ' .. . . . . . ... .. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Container Sizes Specification Product Description United Cleaning Concentrate 1 & 5 Gallon Proprietary Biodegradable cleaning agent with specific functional ingredients for degreasing and removing soils and biological residues for proper cleaning of roof surfaces. HydroStop(X BarrierGuardS 2 & 5 Gallon Proprietary Priming and waterproofing compound for Waterproofing masonry surfaces. SureBond Primer 2 &5 Gallon Proprietary Acrylic primer used for scaling masonry, metal and chalky surfaces. Unibase Primer 5 Gallon Proprietary Low viscosity,highly penetrating,acrylic polymer primer. Lock-Down Primer 1 &5 Gallon Proprietary Moisture-Cure Urethane Primer For Corrosion Protection On Metal Surfaces XR-2000 Primer 5 Gallon Proprietary Water-based Acrylic primer for Kynar coated metal Acrylex 400 Primer 1 &5 Gallon Proprietary .Acrylic latex primer for use over metal, masonry and wood surfaces. F1exSealTM Sealant 1 & 5 Gallon or TAS 139 Solvent-based, elastomeric sealant. I qt. Tube HydroStop®PremiumCoatg 2 & 5 Gallon Proprietary Acrylic elastomeric waterproofing Foundation Coat compound used as a base layer in the PremiumCoat'System. HydroStop®PremiumCoat®Fabric Rolls Proprietary Reinforcing fabric for the PremiumCoat' System and/or BarrierGuard'. HydroStop®PremiumCoat®Butter 2&5 Gallon Proprietary Acrylic elastomeric sealant for bridging Grade Flashing gaps, filling voids and low lying roof areas. United CoatingsTM Roof Mate TCM 2& 5 Gallon TAS 139 Water based,high solids,elastomeric Flashing sealant. NOA No.: 16-0308.02 MAMIO'''DE OU NT Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 2 of 11 :. .: 4, .. .. , . ... . . . . ... TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE I .'. .: .: .•• •� ••• . . . . . . . . . . Test ••• ' Product Container Sizes Specification Product Description United CoatingsTM Roof Mate 5 &55 Gallon TAS 139 Waterba'se�,spr�ayilehigh[}c elastic Liquid Fabric flashing gogipv*v. : • .. . . . • 0900 •. HydroStop®PremiumCoat®Finish 2 & 5 Gallon ASTM D6083 Acrylic elastomeric waterproofing Coat compound used as a top layer in the PremiumCoat®System. HydroStop®TrafficCoat Deck 2 &5 Gallon Proprietary Acrylic elastomeric waterproofing Coating compound used as a non-skid surfacing layer over the PremiumCoat®System. GAF 2-Part Roofing Adhesive 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive LRF Adhesive M 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuardTM Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardTM Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardTM Ultra Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardTM Ultra Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardTM RA Polyiso Insulation Polyisocyanurate foam insulation GAF ACFoam-IV Polyisocyanurate foam insulation Atlas Roofing Corporation Dens Deck® Gypsum Board Georgia Pacific Gypsum LLC Dens Decks Prime® Gypsum Board Georgia Pacific Gypsum LLC NOA No.: 16-0308.02 X10 �� Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 3 of 11 . . ... . . . . ... EVIDENCE SUBMITTED: .•. ••• " ••• Test Ap-ency Test Identifier Test Name/f4o'rt Date Atlantic &Caribbean Roof 09-018 .TAS J 14 •• ••• ••t0/27/09 Consulting,LLC 09-019 '10/27/09 09-020 • •• 40/28/09 12-020 TAS 114 05/08/12 FM Approvals 3031350 FM 4470 09/27/07 3036182 FM 4470 07/31/09 3041769 FM 4470 05/26/11 3045166 FM 4470 07/24/12 3047636 FM 4470 08/08/13 FM Letter 3048066 FM 4470 12/13/13 RR204740 FM 4470 03/29/16 RR204845 FM 4470 04/08/16 RR204846 FM 4470 04/08/16 PRI Construction Materials GAF-369-02-01 ASTM C1289 10/22/12 Technologies LLC GAF-464-02-01 ASTM C1289 02/06/14 GAF-629-02-01 ASTM C1289 03/01/16 GAF-654-02-01 TAS 114 05/19/16 GAF-658-02-01 Proprietary 06/07/16 GAF-659-02-01 Proprietary 06/03/16 GAF-660-02-01 Proprietary 06/03/16 GAF-661-02-01 Proprietary 06/03/16 GAF-662-02-01 Proprietary 06/07/16 GAF-664-02-01 Proprietary 06/03/16 GAF-665-02-01 Proprietary 06/03/16 GAF-667-02-01 TAS 139 07/01/16 GAF-668-02-01 TAS 139 07/01/16 GAF-671-02-01 TAS 139 07/01/16 GAF-674-02-01 Proprietary 06/01/16 GAF-675-02-01 Proprietary 06/01/16 GAF-676-02-01 Proprietary 06/01/16 GAF-678-02-01 Proprietary 07/14/16 GAF-679-02-01 Proprietary 06/01/16 GAF-680-02-01 Proprietary 06/01/16 HSI-007-02-01 ASTM D6083 05/20/16 HSI-009-02-01 ASTM D6083 05/20/16 TrinitylERD 4697.12.00-1 TAS 114 12/07/00 Underwriters Laboratories TGFU.R26758 UL 790 02/09/16 NOA No.: 16-0308.02 !%^MCADE COUN Y Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 4 of 11 APPROVED SYSTEMS: • Membrane Type: Liquid Applied Membrane •; • •; '.: • • Deck Type 3I: Concrete Decks, Insulated •• • Deck Description: Structural Concrete .. . .. 000 •• System Type A(1): Insulation adhered to roof deck. Membrane fully ad4rCdlo:n1ufaliori. • .. • • . . . ... .. HydroStop PremiumCoat®products shall be installed in accordance with the manufacturer's specifications. The following are minimum installation guidelines. Consult the manufacturer's specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Insulation: Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation,EnergyGuard"m Tapered Polyiso Insulation,EnergyGuardIVI Ultra Polyiso Insulation,EnergyGuardTM Ultra Tapered Polyiso Insulation Minimum 1"thick N/A N/A Note: Insulation is adhered with OlyBond®500 Adhesive,OlyBond®500 Green,LRF Adhesive M,Millennium One StepTM Foamable Adhesive,Millennium One Step Green®Foamable Adhesive applied in I"wide ribbons spaced 12"o.c.OR with GAF 2-Part Roofing Adhesive applied in 2.5"wide ribbons spaced 12"o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop®PremiumCoat®Foundation Coat is brush applied over all top insulation layer joints in a 6 in.width at a rate of 1.25 galJsq.centered about each joint. 6 in.wide HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat®Foundation Coat. The fabric is then saturated with additional HydroStop®PremiumCoat®Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStopS PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStopg PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation (Optional) instructions. Maximum Design Pressure: -223 psf (See General Limitation#9) -� NOA No.: 16-0308.02 roah►Cwe Coe�n Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 5 of 11 . . ... . . . . ... Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks,Insulated •• •• • . . . . . . . . . • Deck Description: Structural Concrete '• •• ••• •' System Type A(2): Insulation adhered to roof deck. Membrane fully adhered to insulation. • •• •• HydroStop8 PremiumCoat®products shall be installed in accordance with the ma%ADCOir>rrl ' ci�'icatio04. The following are minimum installation guidelines. Consult the manufacturer's specifioat4n9 or tec neat)eptrsentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation,EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM Ultra Tapered Polyiso Insulation Minimum 1/2"thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft' Dens Deck® Minimum 114"thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5 in.wide ribbons spaced 12"o.c. OR with OlyBond®500 Adhesive,OlyBond®500 Green,LRF Adhesive M,Millennium One Steven Foamable Adhesive,Millennium One Step Green®Foamable Adhesive applied in 0.75"—1.0"wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Insulation Joint Treatment Note: HydroStop®PremiumCoat®Foundation Coat is brush applied over all top insulation layer joints in a 6 in.width at a rate of 1.25 galJsq. centered about each joint. 6 in.wide HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat®Foundation Coat. The fabric is then saturated with additional HydroStop®PremiumCoat®Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are applied at a minimum rate of 0.75 gal./sq.per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation instructions. (Optional) Maximum Design Pressure: -135 psf (See General Limitation#9) NOA No.: 16-0308.02 HLAMMADE M � TY Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 6 of 11 Membrane Type: Liquid Applied Membrane ' . . .. .. . . .. . . Deck Type 3I: Concrete Decks,Insulated •• Deck Description: Structural Concrete System Type A(3): Insulation adhered to roof deck. Membrane fully adhered ti ini6tibr: :. • • • • • • .. HydroStop ufa PremiumCoat®products shall be installed in accordance with the ra cturerts SpCcif eati'ihs. The following are minimum installation guidelines. Consult the manufacturer's specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation,EnergyGuardTM Ultra Polyiso Insulation, EnergyGuardTM Ultra Tapered Polyiso.Insulation Minimum 1.5"thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Dens Deck®Prime® Minimum '/4"thick N/A N/A Note: Insulation is adhered with OlyBond®500 Adhesive,OlyBond®500 Green or LRF Adhesive M, Millennium One StepTM Foamable Adhesive,Millennium One Step Green®Foamable Adhesive applied in 1" wide ribbons spaced 12"o.c.OR with GAF 2-Part Roofing Adhesive applied in 2.5"wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Insulation Joint Treatment Note: HydroStop®PremiumCoat®Foundation Coat is brush applied over all top insulation layer joints in a 6 in.width at a rate of 1.25 gal./sq.centered about each joint. 6 in.wide HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop®PremiumCoat®Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop®PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in.wide seams and is saturated with additional HydroStop® PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are applied at a minimum rate of 0.75 gal./sq.per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation instructions. (Optional) Maximum Design Pressure: -335 psf (See General Limitation#9) NOA No.: 16-0308.02 t► E .�NTY Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 7 of 11 Membrane Type: Liquid Applied Membrane ' . . .. .. . . .. . . Deck Type 3I: Concrete Decks,Insulated • . ... ... .. ... . Deck Description: Structural Concrete ... . . . .. ... .. System Type A(4): Insulation adhered to roof deck. Membrane fully adheredtQ m3uidt�it HydroStop8 PremiumCoat®products shall be installed in accordance with the manufacttirer's spetilWtiBfls. The following are minimum installation guidelines. Consult the manufacturer's specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulation. Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM RA Polyiso Insulation Minimum 1.5"thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5"wide ribbons spaced 12"o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop®PremiumCoat®Foundation Coat is brush applied over all top insulation layer joints in a 6 in.width at a rate of 1.25 gal./sq.centered about each joint. 6 in.wide HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat®Foundation Coat. The fabric is then saturated with additional HydroStop®PremiumCoat®Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop®PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in. wide scams and is saturated with additional HydroStop@ PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStopg PremiumCoat®Finish Coat are applied at a minimum ratc of 0.75 gal./sq.per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation instructions. (Optional) Maximum Design Pressure: -390 psf (See General Limitation#9) NOA No.: 16-0308.02 PGANIMBE COUJtM Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 8 of 11 . ... • . • Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks,Insulated : ': •• • . *00. Deck Description: Structural Concrete • . ... ... .. ... . System Type A(5): Insulation adhered to roof deck. Membrane fully adbgred to iiasulation,.• •• HydroStopS PremiumCoat®products shall be installed in accordance with the matutac01u�r ;s$pecicatiork The following are minimum installation guidelines. Consult the manufacturer's speed ieatibns or`Technical Wepersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulation. Insulation Layers: 'Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-IV Minimum 1.5"thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5"wide ribbons spaced 12"o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop®PremiumCoat®Foundation Coat is brush applied over all top insulation layer joints in a 6 in.width at a rate of 1.25 galJsq. centered about each joint. 6 in.wide HydroStop® PremiumCoat®Fabric is embedded in the wet HydroStopS PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop®PremiumCoat®Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStopS PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStopS PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are applied at a minimum rate of 0.75 gal./sq.per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation (Optional) instructions. Maximum Design Pressure: -287.5 psf (See General Limitation#9) NOA No.: 16-0308.02 �►LE U"Lliyo n Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 9 of 11 • • ••• • • • • ••• Membrane Type: Liquid Applied Membrane .; .'. Deck Type 3: Structural Concrete,non-insulated g % • . ... .:. .. ... . Deck: Structural Concrete System Type F: HydroStop®PremiumCoat@ System applied directly to strurtur*LioActti. : :. •• HydroStop®PremiumCoat®products shall be installed in accordance with theufacturer's 3pccifit'atibhs. The following are minimum installation guidelines. Consult the manufacturer's specifications or Technical Repersentative for specific/complete installation instructions. All General and System limitations apply. Membrane: HydroStop®BarrierGuard®Waterproofing applied in two(2)coats at a rate of 0.67 gal./sq.per coat. SureBond Primer applied at rate of 0.5 gal./sq. HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStopg PremiumCoat8 Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in.wide seams and is saturated with additional HydroStop® PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's installation instructions. (Optional) Maximum Design Pressure: -610 psf (See General Limitation#9) MANUFACTURER'S REQUIREMENTS: 1. Contractor must be a GAF HydroStop&"Approved Applicator",trained and familiar with the details and specifications published by the manufacturer. Proof of this qualification shall be provided in written form from the manufacturer. 2. Refer to GAF's published installation instructions for detailed installation requirements and recommendations. 3. HydroStop®PremiumCoat®TrafficCoat is required for traffic bearing surfaces: All pedestrian traffic areas shall be coated with HydroStop®PremiumCoat'TrafficCoat as non-skid surfacing. CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect,or Registered Roof Consultant. NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 10 of 11 • •• •• • • • •• •• • • • • • • • • • • • • • ••• • • • • ••• GENERAL LIMITATIONS: • 1. Fire classification is not part of this acceptance,refer to a current Approve 414fidg?4at&4s*Directory-for fire ratings of this product. . • 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of apprevtdpphDkaWl1edVithin the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the f4st*4n§p'&tf�-Pi Wthe top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applies iii approted al Iialf and/or adhesives panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8" ribbons in three rows,one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, prepared, signed and scaled by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e. perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF TMS ACCEPTANCE NOA No.: 16-0308.02 MUxHMD,Ei _ Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 11 of 11 r , Exception: Metal roofs constructed of cold-formed steel,where the roof deck acts as the roof covering and provides both weather protection and support for structural loads, shall be permitted to be designed and tested in accordance with the applicable referenced structural design standard in Section 2210.1. 1604.4 Ballasted low-slope roof systems. Ballasted low-slope(roof slope <2:12) single-ply roof system coverings installed in accordance with Sections 1507.12 and 1507.13 shall be designed in accordance with Section 1504.8 and ANSI/SPRI RP-4. 1504.5 Edge securement for low-slope roofs. Low-slope built-up, modified bitumen and single-ply roof system metal edge securement,except gutters,shall be designed and installed for wind loads in accordance with Chapter 16 and tested for r resistance in accordance with Test Methods RE-1,RE-2 and RE-3 of ANSI/SPRI ES-1, or RAS 111, except V,,wind speed shall be determined from Figure 1609A, 1609B, or 1609C as applicable. t 1504.6 Physical properties. Roof coverings installed on low-slope roofs(roof slope<2:12) in accordance with Section 1507 shall demonstrate physical integrity over the working life of the roof based upon 2,000 hours of exposure to accelerated weathering tests conducted in accordance with ASTM G 152, ASTM G 153,ASTM G 155 or ASTM G 154. Those roof coverings that are,subject to cyclical flexural response due to wind loads shall not demonstrate any significant toss of tensile strength for un�einforced membrages"r• breaking strength for reinforced membranes when tested as herein required. •••• ••••;• 1504.7 Impact resistance. •••••• • ...... . ...... Roof coverings installed on low-slope roofs (roof slope<2:12)in accordance with JE"on 1507-shall • resist impact damage based on the results of tests conducted in accordance with•A STM D=x'40,• ••• ASTM D 4272, CGSB 37-GP-52M or the'Resistance to Foot Traffic Test"in Seuenl 5 of FM•4470_ ••••• All structural metal roofing systems having a thickness equal to or greater than 22 ari •erlf;•• ••�•• nonstructural metal roof systems having a thickness equal to or greater than 2v_ab`cKshall ber• _""�• exempt from the tests listed above. �'•�• •� 1504.8 Aggregate. •••••• -g:-_ ` Aggregate shall be permitted as roof surfacing when installed on slopes of 3:1 ori-;, nod le Nan ce• t 400 pound (182 kg)of roofing gravel or 300 pounds(145 kg)of slag per square_sfiall be ap t pT�ied.A - - ' minimum of 50 percent of the total aggregate shall be embedded in the flood c4�: ofibitumpn or, installed in accordance with its product approval.Aggregate shall be dry and free from dirtJtt&shall 1 be in compliance with the sizing requirements set forth in ASTM D 1863. A building official Moy request a test to confirm compliance with these requirements. Table 1504.8 Maximum Allowable Mean Roof Height Permitted For Buildings With Aggregate On The Roof In Areas Outside A Hurricane-Prone Region. } Reserved. 1604.9 Margin of Safety. A margin of safety of 2:1 shall be applied to all wind-uplift-resistance test results except when a margin of safety is specifi n the test stan ;. Exception: Asphalt ingles testi ting in a miles pe ting as required in Section 1507.2.7. , E SECTION 1505 FIRE CLASSIFICATION 1506.1 General. Roof assemblies shall be divided into the classes dem �elowClass , Band C roof assemblies t and roof coverings required to be listed by this section shall be tested in accordance with ASTM E 108 or UL 790. In addition, fire-retardant-treated wood roof coverings shall be tested in accordance ' with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with Table 1505.1 based on the type of construction of the building. Exception: Skylights and sloped glazing that comply with Chapter 24 or Section 2610. r TABLE 1505.1•'1, MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION IA 113 IIA IIB IIIA 1118 °IV VA VB B I B B C- --B--7 CC For SI: 1 foot=304.8 mm, 1 square foot=0.0929 m2. a. Unless otherwise required in accordance with the International Wildland--Urban Interface Code or due to the location of the building within a fire district in accordance with Appendix D. b. Nonclassified roof coverings shall be permitted on buildings of Group R-3 and Group U occupancies,where there is a minimum fire-separation distance of 6 feet measured from the leading edge of the roof. c. Buildings that are not more than two stories above grade plane and having not more than'6,000 square feet of projected roof area and where there is a minimum 10-foot fire-separation distare1, from the leading edge of the roof to a lot line on all sides of the building, exceptfor street frontsao •••••• public ways, shall be permitted to have roofs of No. 1 cedar or redwood shakes ar4d rso. 1 siiipens • constructed in accordance with Section 1505.7.• 000:0* • .•0000 i 1505.2 Class A roof assemblies. 000:0. 0000.. Class A roof assemblies are those that are effective against severe fire test exppsvte„Clafi!:-&tW • assemblies and roof coverings shall be listed and identified as Class A by an apprbl�bd tesng agency. Class A roof assemblies shall be permitted for use in buildings or stru--"L Mtf all*Zy�iit: construction. .� 00 0 ••0y•• Exceptions: •••••• __ ` • • ".__�� 0000.. 1. Class A roof assemblies include those with coverings of brick, masonry or a11*tVftq,-d conF;ef,3 '""•• roof deck. - ti- -- - i 2. Class A roof assemblies also include ferrous or copper shingles or sheets, rn'0-xal-sheetsvd shingles, day or concrete roof the or slate installed on noncombustible decks or ferrous, cd'pper or metal sheets installed without a roof deck on noncombustible framing. _ 3. Class A roof assemblies include minimum 16 oz/sq.ft. (0.0416 kg/M2) copper sheets installed over combustible decks. 1505.3 Class B roof assemblies. Class B roof assemblies are those that are effective against moderate fire-test exposure. Class B roof assemblies and roof coverings shall be listed and identified as Class B by an approved testing agency. 1505.4 Class C roof assemblies. Class C roof assemblies are those that are effective against light fire-test exposure. Class C roof assemblies and roof coverings shall be listed and identified as Class C by an approved testing agency. 1505.5 Nonclassified roofing. i Nonclassified roofing is approved material that is not listed as a Class A, B or C roof covering. 1505.6 Fire-retardant-treated wood shingles and shakes. Firs-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by - a F 7 TM-- CERTIFICATE OF ACHIEVEMENT This certifies that d PaulJaner of Ocean Contractors Group, LLC. CCC# 47137 Successfully completed "101 Liquid-Applied Roofing" training event-provided by GAF. - November 171h 2016 - Miami, FL .. ... . . . . . .. '.?Ais ce4ificate is valid for 2-year from the above date T - - - -- ..•- - .- ... -- �� � I I� III I Daniel Pena, Todd Reitz,: : : : : Technical Sales Representative Regional Dirjet;pr ;• ' .'• :• ' sLIQUID-APPLIED GAF Liquid-Applied Division GAF Liquid-Applied•Divisien • • .. :r..y°8tA1, k W _. SECTION"1524 HIGH VtdITY HURRICANE ZONES—REQUIR,kD OWNERS'NOTIFICATION FOR:Rt}OFING' CONSIDERATIONS 1524.1 Scope.As it pertains to the section,it is":the responsibility of roofing contractor to provide'the owner with a the.required roofing permit;and to explain oto the owner the content of this sectio& The,pravisions of Section R4402 govern the minimum requirements�and standards of the industry'for roofing system insialiation,&Additionally,the foNowing items should be addressed as part.of the.agreement between the'owner'ant`the conteactdr.=The owner's' initial in`the,designated space`indicates that the°item has been explained: fZenaihng wood decks:liVhen replacing rooting,the existing wood'roof deck,may:Have to be renailed in accordance'with the current provisions of Section 84403.(The.roof deck is usually concealedp 9 nor to removing the existing root system): 4• <- Exposed Celling:Exposed;open beam ceilings are where the • •••• •••••• - t>t>t�tsrQe of`�roo�`decking� •' -can be viewed from below:The`owner may wish to*maintairi-the architectural appearance;-tbeie36re, •••0:0 roofing nail penetration of:the underside of the decking may not be acseptabla•T.Akt provides the "option 6t....; .maintaining the appearance. ..... . . ...... .... . ..... ...... .. . ..... S• , Overflow icu r$ wall outlets It js' •• • ••••.• . pts � ) required that rainwater flow.�p�fso tha#the�oof i5` .' not overloaded from a buildup of water. Perimeter/edge-wail or other roof extepsioti rgay block this ....:. discharge If overflow scuppers-(wall outlets)are not provided. it may'be neces�a y to install VOM • scuppers m:accordance with the requirements of Sections R4402,84401 d'R4d't3; 4•• •ttq(o •• • so 0 s Signature D to 9 Contractor Signature ate ` J-00 W to l sr. Propert,,Address` Permit Number `Revised on 7/9/2009 LD,0710112015;' t e Iliad a G�a�� f� F �F I iEf a �t�d FI� E ❑o ; ") �g a a i m 81a 1i aaa" � Mill1911 , � � a . . a �� ll j1 , isaa1 0 0 0o a00000a©o©ao 0o 4v A-1 SE 1:01 r , x �* ••••• C r \ /\ •• • �•..••• • • •• • - � r t HIAM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www.miamidade.gov/economy ZGApus Driveppany,N 054 This NOA is being issued under the applicable rules and regulations governing the use ot'cogsx ction materials he documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product ` 1 Secti,n to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves tj terigtt to revoke this acceptance, if it is determined by.Miami-Dade County Product Control Sectibn that this pfdddct or *Gee:* material fails to meet the requirements of the applicable building code. •• :...:. •. This product is approved as described herein, and has been designed to comply with the Flori l; gilding Code • including the High Vv eloci H rricane Z f the F Toricla. ut i •••• • .... . ..... DES ON: HydroStop®PremiumCoat® System over Concrete Decks. r • . ... .. . ..... LA ac unit shall bear a permanent label with the manufacturer's name or logo:eitY!Itate and fallowing •• statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein' ... . '•'•'• RENEWAL of this NOA shall be considered after a renewal application has been filed and 14ere:tas beenng change•••• in the applicable building code negatively affecting the performance of this product. •..•.• TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ; ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.13-0204.16 and consists of pages 1 through 11. The submitted documentation was reviewed by Gaspar J Rodriguez. 'F NOA7Date: - F E tion 06/22/18 Approval 10/27/16 ge 1 of 11 r r r ROOFING SYSTEM APPROVAL Category: Roofing f Sub-CateQory: Liquid Applied Membrane ' Deck Tyne: Concrete Material: Elastomeric Maximum Deshm Pressure: -610 psf r TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: R TABLE 1 Test Product Container Sizes Specification Product Description United Cleaning Concentrate 1 &5 Gallon Proprietary Biodegradable cleaning agent with specific functional ingredients for degreasing and removing soils and biological residues for proper cleaning of roof surfaces. HydroStop®BarrierG 2&5 Gallon Proprietary Priming and waterproofing compound for 0 Wate r masonry surfaces. •••• •••••• SureBond Primer 2&5 Gallon Proprietary Acrylic primer vseA far seal*flf Monty....... metal and chalkW0su faces. 0000.. •.•• Uni rimer 5 Gallon Proprietary Low viscosity,11W ;pene4fibj,,hcrylia.... polymer primer...... .. .. .. 0000.. Lock-Down Primer 1 &5 Gallon Proprietary Moisture-Cure jJrgtjLVe Primer.For .• Corrosion Prot&tioh On Metal Surfaces .0000. XR-2000 Primer 5 Gallon Proprietary Water-based Acrylic primer f9j Kynar 0•••• coated metal •..•.• Acrylex 400 Primer 1 &5 Gallon Proprietary Acrylic latex primer for use over metal, masonry and wood surfaces. F1exSealTM Sealant _ 1 &5 Gallon or TAS 139 Solvent-based,elastomeric sealant. 1 qt.Tube ydroStop®PremiumCo 2&5 Gallon Proprietary Acrylic elastomeric waterproofing Foundation Coat compound used as a base layer in the PremiumCoat®System. HydroStopO PremiumCoat®Fab ' Rolls Proprietary Reinforcing fabric for the PremiumCoat® System and/or BarrierGuard®. HydroStop®PremiumCoat®Butter 2&5 Gallon Proprietary Acrylic elastomeric sealant for bridging Grade Flashing gaps,filling voids and low lying roof areas. United CoatingsTM Roof Mate TCM 2&5 Gallon TAS 139 Water based,high solids,elastomeric Flashing sealant. }} r 1 NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 2 of 11 4 r F TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Container Sizes Specification Product Description United CoatingsTM Roof Mate 5 &55 Gallon TAS 139 Water based,sprayable highly elastic Liqu' nc flashing compound. HydroStop®PremiumCoat®Fini 2&5 Gallon ASTM D6083 Acrylic elastomeric waterproofing i Coat compound used as a top layer in the ' PremiumCoat®System. a HydroStop®TrafficCoat Deck 2&5 Gallon Proprietary Acrylic elastomer'ic waterproofing ' Coating compound used as a non-skid surfacing layer over the PremiumCoat®System. f GAF 2-Part Roofing Adhesive 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive 1 LRF Adhesive M 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive 0000 . . 0000 0000.. APPROVED INSULATIONS: •••• •• TABLE •���•• 0000.. . 0000.. Product Name Product Description "'010fanu6cturer :0000: •W hh CurIrE1ltAOA) :.906*••0•• EnergyGuardTM Polyiso Insulation Polyisocyanurate foam insulation •• .. .. . 0000.. EnergyGuardTM Tapered Polyiso Insulation ' Polyisocyanurate foam insulation •••••• GAF • EnergyGuardTM Ultra Polyiso Insulation Polyisocyanurate foam insulation GAS • . ••t••• EnergyGuardTM Ultra Tapered Polyiso Insulation Polyisocyanurate foam insulation .. GA-F• EnergyGuardTM RA Polyiso Insulation Polyisocyanurate foam insulation GAF ACFoam-IV Polyisocyanurate foam insulation Atlas Roofing Corporation Dens Deck® Gypsum Board Georgia Pacific Gypsum LLC Dens Deck®Prime® Gypsum Board Georgia Pacific Gypsum LLC i NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 3 of 11 , EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Report Date Atlantic&Caribbean Roof 09-018 TAS 114 10/27/09 Consulting,LLC 09-019 TAS 114 10/27/09 09-020 TAS 114 10/28/09 12-020 TAS 114 05/08/12 FM Approvals 3031350 FM 4470 09/27/07 3036182 FM 4470 07/31/09 3041769 FM 4470 05/26/11 3045166 FM 4470 f 07/24/12 3047636 FM 4470 08/08/13 FM Letter 3048066 FM 4470 12/13/13 x RR204740 FM 4470 03/29/16 RR204845 FM 4470 f 04/08/16 RR204846 FM 4470 04/08/16 '.... PRI Construction Materials GAF-369-02-01 ASTM C1289 • •ID( 2/12 .... • Technologies LLC GAF-464-02-01 ASTM C12'8A' 02406/14 GAF-629-02-01 ASTM C 1336 9.. :•Wdl/16 .... :• GAF-654-02-01 TAS 114-9—� 05/19/16 ;•••�; GAF-658-02-01 Proprietary" :.06247/16 GAF-659-02-01 Proprietary•••• •06/03/16 ••• GAF-660-02-01 Proprietary.• •• 67.03/16 • • GAF-661-02-01 Proprietary.•••. 06/03/16 GAF-662-02-01 Proprietar3 06407/16 ....:. GAF-664-02-01 Proprietary ••• •560.3/16 •••• GAF-665-02-01 Proprietary'• .-06V/16 GAF-667-02-01 TAS 139 007701/16 GAF-668-02-01 TAS 139 07/01/16 GAF-671-02-01 TAS 139 # 07/01/16 GAF-674-02-01 Proprietary 06/01/16 GAF-675-02-01 Proprietary 06/01/16 GAF-676-02-01 Proprietary 06/01/16 GAF-678-02-01 Proprietary 07/14/16 GAF-679-02-01 Proprietary 06/01/16 GAF-680-02-01 Proprietary 06/01/16 HSI-007-02-01 ASTM D6083 05/20/16 HSI-009-02-01 ASTM D6083 05/20/16 TrinitylERD 4697.12.00-1 TAS 114 12/07/00 Underwriters Laboratories TGFU.R26758 UL 790 02/09/16 NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 4 of 11 J r Membrane Type: Liquid Applied Membrane Deck Type 3: Structural Concrete,non-insulated Deck: Structural Concrete System Type F: HydroStop®PremiumCoat® System applied directly to structural concrete. HydroStop®PremiumCoat®products shall be installed in accordance with the manufacturer's specifications.The following are minimum installation guidelines. Consult the manufacturer's specifications or Technical Repersentative for specific/complete installation instructions. 1 Al - Hera d, stem limitations apply. Membra HydroStop®BarrierGuard®Waterproofing applied in two(2)coats at a rate of 0.67 gal./sq.per coat. , SureBond Primer applied at rate of 0.5 gal./sq. HydroStop®PremiumCoat®Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop®PremiumCoat®Fabric is embedded in the wet HydroStop®PremiumCoat® Foundation Coat base coat within 4 in.wide seams and is saturated with additional HydroStop® q' PremiumCoat®Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. �• ••- �i 0099 990009 Two(2)or more coats of HydroStop®PremiumCoat®Finish Coat are htpli�d at a minimrnum rate •9 .. .. . of 0.75 gal./sq.per coat. • 000000 0000.. 0000.. Surfacing: HydroStop®TrafficCoat Deck Coating applied per manufacturer's inst;rlft on ins*vr.Ubns. • (Optional) *• Maximum Design •• •• •• •••••• Pressure: -610 psf (See General Limitation#9) ""•' • 0000.. 0000.. MANUFACTURER'S REQUIREMENTS: '.. .• 1. Contractor must be a GAF HydroStop®"Approved Applicator",trained and familiar with the details and specifications published by the manufacturer. Proof of this qualification shall be provided in written,form from the manufacturer. 2. Refer to GAF's published installation instructions for detailed installation requirements and recommendations. 3. HydroStop®PremiumCoat®TrafficCoat is required for traffic bearing surfaces: All pedestrian traffic areas shall be coated with HydroStop®PremiumCoat®TrafficCoat as non-skid surfacing. r r CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the-lightweight insulating concrete is proposed; a field withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, ' Registered Architect,or Registered Roof Consultant. NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 10 of 11 i e r GENERAL LIMITATIONS: r 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire ` ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt and/or adhesives panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12"diameter circles,24" o.c.;or strip mopped 8"ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to,a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value;as field-tested,are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is base6on a minimum fastener resistance value in conjunction with the maximum design value listed within a�SpeciFic system.Should •,' the fastener resistance be less than that required,as determined by the Building Official j%rwised Mtdii!'r spacing,:. prepared,signed and sealed by a Florida registered Professional Engineer,Registered A c6tect,or Registered *•• Roof Consultant may be submitted. Said revised fastener spacing shall utilize the witV"N resis1,rlVvalue • • taken from Testing Application Standards TAS 105 and calculations in compliance withRdofmg Application Standard RAS 117. *0:00: *00 0 .. .. .. 0000.. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements pf jese areas..Fastener .• densities shall be increased for both insulation and base sheet as calculated in complial►cewh Roofing. *000:0 Application Standard RAS 117.Calculations prepared,signed and sealed by a FloridaG egiiste�red Professional 0 0 • Engineer,Registered Architect,or Registered Roof Consultant •• losses • (When this limitation is specifically referred within this NOA,General Limitation#9 will not 6e applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. , 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall hav ity assurance audit in accor a 'th the Florida Building Code and Rule 61G20-3 of the Florida ministrative Code. END OF THIS ACCEPTANCE a NOA No.: 16-0308.02 Expiration Date: 06/22/18 Approval Date: 10/27/16 Page 11 of 11