Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-17-2887 (2)
i Permit No. RF-12-17-2887 Miami Shores Village Permit Type:Roof 10050 F' N.E.2nd Avenue NE s l' r l� ' Work Classification:TilelFlat Miami Shores,FL 33138-0000 Phone: (305)795 2204 Permit Status:APPROVED FLORtD4' Issue Date: 12/12/2017 Expiration: 06/10/2018 Project Address Parcel Number Applicant , 296 NE 99 Street 1132060134300 Miami Shores, FL 33138- Block: Lot: JEFF KAMP BARBARA KAMP Owner Information Address Phone Cell JEFF KAMP BARBARA KAMP 296 NE 99 Street MIAMI SHORES FL 33138- 296 NE 99 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone PERKINS ROOFING CORPORATION Valuation: $ 26,800.00 (305)687-6521 (786)277-8486 -- - Total Sq Feet: 3200 I Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF TILE TO TILE AND FLAT Inspection Type: Classification:Residential InIn Scanning:3 Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof I Review Roof Review Roof Cap Sheet 1 F Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-12-17-65843 { CCF $16.20 DBPR Fee $4.88 12/12/2017 Check#:2133 $885.33 $0.00 DCA Fee $3.25 Bond#:3590 Education Surcharge $5.40 Permit Fee-New Roof $325.00 Scanning Fee $9.00 Technology Fee $21.60 Total: $885.33 g f E In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores'Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and o ing. Futhermore,I authorize the above-named contractor to do the work stated. December 12, 2017 e t Authorized Signature:Owner / App scant / Contractor / Agent Date i Building Department Copy December 12,2017 1 Inspection Worksheet Miami Shores Village 10030 N.E.2nd Avenue Miami Shores,FL Phone:(301)793-2204 Fax:(305)756.8972 inspection Number: IN$P-297404 Permit Number. RF-12-11-2887 Scheduled Inspection Date: February 16,2018 Permit Type: Roof Inspector Alvarez,Manny Angel Inspection Type: Final Roof a Owner: BARBARA KAMP,JEFF KAMP Work Classification: Tile/Flat Job Address:296 NE 99 Street Miami Shores,FL 33138- Phone Number Parcel Number 1132060134300 Project: <NONE> Contractor. PERKINS ROOFING CORPORATION Phone:(303)687.6321 Building Department Comments RE-ROOF TILE TO TILE AND FLAT InWactio aaeed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP 296922.CREATED AS REINSPECTION FOR INSP 296683. CREATED AS REINSPECTION FOR INSP-293527. by maria f � Failed MISSING UPLIFT TEST AND NEED TO SEAL END OF METAL FLASHING 2/13/2018 1 Correction ALL ROOF DEBRVMATERIALS MUST BE REMOVE FROM ROOF DECK. Needed ,. Re-Inspection Fee No Additional inspections can be scheduled until reinspection fee is paid. F Febnnry 15,2018 For Inspections please Call:(30;5)762-4949 Page 26 of 40 i i Miami Shore's Village Building Department 10050 N.E.2nd Avenue ` r Miami Shores, Florida 33138 IORiD� Tel: (305)795.2204. Fax: (305) 756.8972 i RE: Permit# v I DATE: i { INSPECTION AFFIDAVIT licensed as a(n)Contractor/Engineer/Architect, (Print name and drde License Type) FS 468 Building Inspector License#: C CC 044;2 7 Y6 i On or about 1000 2.C�-1 , 1 did personally inspect the roof deck nailing (Date 8�tim,.e.) work at (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual on 553.844 F. �e1 Signature Y 4 7 6 State of Florida County of Dade: } The undersigned, being the first duly swom,deposes and says that he/she is the contractor for the above property mentioned. V. Sworn to and subscribed.before me this �i S day of _ wwo.cava Notary Public, Sate of Florida at Large Gata(on cslsa�� R Expires:October 12,2021 Bonded thrc kir-in Notary i a " "General,Building,Residential,or Roofing Contractors or any individual certified under 466 F.S.to make such an inspection.Include photographs of each plane of the roof with permit#and address#deady shown marked on the deck for each inspedlon f Paukad—rmmnrx 1A18;n1PXM } I 5gORES Miami shores V NINE ,.,. Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305)756.8972 RE: Permit#. 7 oZf �7 DAT Z E. INSPECTION AFFIDAVIT 1 Urlci Pre j- licensed as a n Contractor Engineer eer/Architect, (Print name and circle License Type) FS 468 Building Inspector License M On or about Z/"l7 1 did personally inspect the roof deck nailing (Date&time) JJ work at �lo All J' �(m / J /k6i►tom. �L (Complete Job Site Address) , Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (B d on 553.844 F Signature 4 State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this _day of Notary Public, Sate of Florida at Large v'� i aw0.cafo Commission rf 66150917 Expires:OcWW 12.2021 Bonded ov Aaron Notary 'General,Building,Residential,or Roofing Contractors or any individual certified under 468 F.S.to make such an inspection.Include photographs of each plane of the roof with permit#and address#clearly shown marked on the deck for each inspection ao,a�o,��„(711 M'M��1FI9'INMl10 k P r •� ; Miami Shores Village RECEIVED Building Department �DEC 0/►7 1011 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 i FBC 201 BUILDING Master Permit No. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC 5Q ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING M MECHANICAL MPLIBLICWORKS MCHANGEOF ❑CANCELLATION SHOP I CONTRACTOR DRAWINGS i JOB ADDRESS: 2-�CD NF 3 S`T t City: Miami Shores County Miami Dade Zio 3�J 13 6 Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): 'I-p—T:--F— Ph1 one#: 1 Address: >q( q City: l Q AAt &O e 4M State: Tlo lei d e Zip: LZ'j %3 a Tenant/Lessee Name: Phone#: -� Email: \aV a �y01(Y�i�� • � CONTRACTOR:Company Name:_PeakiwsO Phone#:.3OS (D t4 0 S I A dress: A 52 S e e City 1 v l 1 (�1 1�A 1 State:f)— Z ?J31(0 9 y Qualifier Name: �I ear-j Peh,/F i 14S Phone#:6' , a- �a _lW ' State Certification or Registration#: CCS O Z_Me Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Vi aloe of Work �tfiis Perm :$ Z�Q�G1�. Square/Linear Footage of Work: �J ZOcs S Type of Work: ❑ Addition ❑ Alteration ❑ New EC Repair/Replace ❑ Demolition Description of Work: re- r ooF' -}-i Lp_ To T, L:[-� rA azt- Specify color of color thru tile: s�0&e W rl h 1>1 incK Cie a L& F SIAL'-M Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ E TOTAL FEE NOW DUE$ (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lendees Name(if applicable) Mortgage Lender's Address Cit State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the Issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 'WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property Is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice; the inspection will not be approved and a reinspection fee will be charged. Signature Signature ---j L OWNER or AGENJ CONTRACTOR ' The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 2—day of -_ • -.0201-7 by _ 7 day of De 6' 20 /7 by who is personally known to C'U?GZ Wi zt' 63yho i ersonally known me or who hes produced G(- as me or who has produced as identification and who did take an oath. identification and who did take an oath NOTARY PUBLIC: - NOTARY PUBLIC: Sign: Sign: Print: ld � Print: ' Seal: ISD Cefio Seal: Co T:ie; mmissioni GG150917 D.cooExpires:October 12,2021 Comsion mist GG15M? Bonded thru ron N "= Expires:October 12,2021sssssssss s*s8 �isssss s*ss*ss******ss**sss*ss *srg� J e B ►ssssssssssssss V1 APPROVED BYy r Plans Examiner Zoning Structural Review Clerk (Revlsed02/24/2014) d Property Search Application-Miami-Dade County Page 1 of 1 OFFICE OTHE PROPERTY A Summary Report f Generated On:11202017 9 Property Information Folio: 11-3206-013-4300 : Property Address: 296 NE 99 ST ;:• Miami Shores,FL 33138-2435 Owner JEFF KAMP BARBARA KAMP Mailing Address 296 NE 99 ST r' MIAMI,FL 33138 USA40 ' PA Primary Zone 1000 SGL FAMILY-2101-2300 SQ 0101 RESIDENTIAL-SINGLE z, Primary Land Use FAMILY:1 UNIT Beds I Baths/Half 3/3/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft P Adjusted Area 2,481 Sq.Ft Taxable Value Information , Lot Size 8,998.75 Sq.Ft 2017 2016 2015 Year Built 1941 County Exemption Value 1 $50,000 $50,000 $50,000 Assessment Information Taxable Value 1 $249,0821 $242,9311 $240,895 Year 2017 2016 2015 School Board Land Value $ 225,059 $216,204 Exemption Value 1 $25,000 $25,000 $25,000 Building Value 181518 $118,872 $119,227 Taxable Value 1 $274,082 $267,931 $265,895 XF Value $0 $0 $0 City Market Value ,588 v$343,931 µ$335,431 Exemption Value 1 $50,000 $50,000 $50,000 Assessed Value $299,0821 $292,931 $290,89.5 Taxable Value 1 $249,082 $242,931 $240,895 Regional Benefits Information Exemption Value $50,0D01 $50,000 $50,000 Benefit Type 2017 2016 2015 Taxable Value 1 $249,082 $242,931 $240,895 Save Our Homes Assessment Cap Reduction $89,506 $51,000 $44,536 Sales Information Homestead Exemption $25,000 $25,000 $25,000 Previous Sale Price OR Book-Page Qualification Description Second Homestead Exemption $25,0001 $25,0001 $25,000 0625/2012 $300,000 28167-0087 Qual by exam of deed Note:Not all benefits are applicable to all Taxable Values(i.e.County, 02/012006 $555,000 24308-0511 Sales which are qualified School Board,City,Regional). 02/01/1995 $125,000 16699-0814 Sales which are qualified Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 1&E12 LOT 2 BLK 32 LOT SIZE 78.250 X 115 a COC 24308-051102 2006 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current imbrmation on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.govfinfo/disdaimer.asp Version: http://www.miamidade.gov/propertysearch/• 11/20/2017 I Miami Shores Village lose Building Department 10050 N.E.2nd Avenue ---- - ` �, � Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305)756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: % Z 10050 NE 2nd Ave Miami Shores, A 33138 q Re: Owner's Name: �� W4 me Property Address: St Roofing Permit Number: Dear Building Official: I_��ecertify that I am not required to retrofit the roof to wall connections of my building ecause: I e just valuation for the structure for purpose of ad valorem taxation J p rp at is less than$300,000.00. Please attach proof of ad valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 1994 edition of the South Florida Building Code(1994 SFBC) Oggtu Print Name State of Florida County of Dade 1. The undersigned, being the first duly sworn,deposes and says that he/she is the owner for the above property'mentioned. Sworn to and subscribed before me this St day of ��V wuro caMq =K Conn ftM # GGISM? Notary Public, Sate of Florida at Large `F 'r. .° EBBoondedh rtu Aaron2Notary When the Just valuation of the structure for purpose of ad valorem taxation Is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building appliration from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 i . a Peridns Roofing Corporation 575 NW 152 Street �— Miami, FL 33169-6615 US PERKINS ROOFING (305) 687-6521 CORP. vp@perkinsroofing.net (3051667-6521 www.pL*nrroofing.nei www.perkinsroofing.net ADDRESS ESTIMATE 2653 Jeff Kamp 296 NE 99 Street DATE Miami Shores, FL 33138 SALES REP Tim Kanak, VP ACTIVITY AMOUNT NEW CONCRETE TILE ROOF AND NEW SLOPED FLAT ROOF(W/ TAPERED INSULATION SYSTEM) ---TILE RE-ROOF--- Specifications of Proposed Work: 1. Obtain the roofing permit. We do all processing, you pay permit fee(s) only. 2. Tear off existing roof system and dispose of debris. 3. Replace any damaged or rotten decking wood as needed. An allotment of 100 linear feet of decking wood (total) is included at no additional charge. Any additional decking wood) discovered over 100 linear feet will be replaced at our cost of$3.00 per linear foot and invoiced. Any other wood types possibly needed are installed and invoiced at$45. per man/hr plus the wood cost. Note if plywood decking: An allotment of 2 sheets of plywood (installed) is included at no additional charge. Any additional damaged pplywood discovered over 2 sheets, will be installed at our cost of$65. per sheet and invoiced to you. 4. Re-nail existing decking and/or sheathing using 8d ring shank nails per revised Florida Building Code. 5. Install one layer of ASTM 30#felt using 1-1/4 inch ring shank nails and Miami-Dade approved tin tags. 6. Fabricate, prime, and install factory Painted perimeter drip edge metal. This metal is to be fastened every four inches using 1-1/4 inch ring shank nails. 7. Install ASTM Certified roof tile underlayment. 8. Install new 16 inch 26 gage galvanized metal in all roof valleys. 9. Install quality concrete roof tiles: 13 inch concrete flat tile, or concrete roll tile, in any standard color. Install tiles set in 3M Polyfoam tile adhesive. Selection of a more expensive tile will increase the quoted pricing. f 10. Install 26 gage galvanized hip and ridge anchor metal. , 11. install new hip and ridge tiles and point them up with mortar, your choice of color. FL State Certified CCCO42786 i i Y . t f • ACTIVITY AMOUNT ---TILE RE-ROOF---- Specifications of Proposed Work: 12. Replace all plumbing vent flashings. 13. Replace "all purpose"ventilators with new. 14. Clean up and haul away debris daily. ---BUILT-UP INSULATED POLYGLASS ROOFING SYSTEM--- Specifications of Proposed Work To Replace Hurricane Damaged Roofing: 1. Tear off the existing damaged roofing down to the deck. There are multiple layers of roofing systems to be removed. 2. See "wood clause" above under#3. 3. Install minimum 1 1/2" Poly Iso insulation board with screws and plates. 4. Install a tapered board insulation system for roof drainage with adhesive. 5. Install a Polyglass SA V modified bitumen interply and continue up the parapet walls to termination. 6. Install a Polyglass SAP modified bitumen roof system, white granulated. 7. Install new metal flashings at wall terminations. 8. Replace all plumbing vent flashings with new. 9. Clean up and haul away debris daily. ---ADDITIONAL INFORMATION--- 1. All roof work done in accordance with the high velocity hurricane zone section of the Florida Building Code. 2. Permitting and processing is done by Perkins Roofing Corp. for no additional fee. 3. Permit and Engineering fees will be an additional charge to the price given below. ---WARRANTY-- _ Perkins Roofing Limited Warranty of TEN year(s) upon final payment and signed Perkins Roofing Limited Warranty certificate _ Total -- —� 26,800.00 Includes all service dates, skilled techs,•supplies and materials,waste service fee,taxes and insurance. —TERMS--- 5% --TERMS- -5%upon acceptance 30% upon mobilization and start-up of permitted job 35%when roof is sealed and water-tight (installation of base sheet) Remaining net balance due upon completion of proiect ---FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND--- Payment, up to a limited amount, may be available from the Florida Homeowners' Construction Recovery Fund if you lose money on a project performed under contract, where the loss results from specified violations of Florida Law by a licensed contractor. For information about the recovery fund and filinga claim, contact the Florida Construction Industry Licensing Board at the ollowing telephone number and address: 1940 North Monroe St. Tallahassee, FL 32399-0783 Telephone: 850-487-1395 Website: www.myfloridalicense.com E FL State Certified CCCO42786 i ACTIVITY AMOUNT ---CONTRACT PROVISIONS--- 1. LIABILITY: It is agreed that Perkins Roofing Corporation is liability insured as per Florida Law, but will not be held responsible for construction effects such as but not limited to dust, dirt, noise, asphalt, landscape,walks, drives, sudden rainstorms or any accident beyond our control. 2. WARRANTY:Any warranty shall apply to specifications only and does not cover additional damage to property. 3. Damage to roof caused by obvious circumstances such as but not limited to trees, footwear, termites, mold, additional work done by others, etc. is also not warranted. 4. EXISTING STRUCTURE: Perkins Roofing Corporation can not be held liable for undetectable deficiencies within the existing structure/deck underneath the roofing system. 5. DEMOBILIZATION: If asked to demobilize by the owner, property manager or GC for whatever reason, all Perkins Roofing Corp, expenses, including profit and overhead will be covered up to the point of demobilization. 6. ADDITIONAL TERMS AGREEMENT: In the event payment is not made as agreed in Terms, all fees incurred in collection are to be paid by owner or signer. 7. LATE FEES: If payment surpasses 30 days overdue, a late fee of 5%of the total amount due will be charged in addition to the remaining total amount due. The 5% late fee will be continuously applied every 30 days overdue unless otherwise specified within the contract. 8. LIEN RIGHTS: If payment has not been received once 45 days overdue, Perkins Roofing Corp: has the right to process a claim of lien unless otherwise specified within the contract. 9. WRITTEN NOTICE: Florida law states written notice must be delivered to Perkins Roofing Corp. regarding any potential defects and Perkins Roofing must be given the opportunity to correct such defects 60 days prior attempting any legal action. 10. ATTORNEY FEES: In the event of a legal dispute,the defeated party will pay reasonable attorney fees and travel expenses related to a legal dispute. 11. CREDIT CARDS: Payment with credit card will result in a 3%increase in the total amount due {{all major credit cards are accepted. 12. CASH BACK FOR REVIEWS: If you provide us a positive review on Google, Facebook and Yelp, Perkins Roofing Corp. will discount your total bill $25. FL State Certified CCCO42786 r +r ACTIVITY AMOUNT ---CONTRACT PROVISIONS--- 13. NAMED STORM PRICING: Potential named storm threats may affect material pricing and availability. in the instance of a Named Storm landing in South Florida, Perkins Roofing must be compensated regarding pricing increases and scheduling issues due to material delays or unworkable weather. 14. PRICE QUOTE: This estimate will be automatically withdrawn if not accepted within ninety(90) days. 15. The above prices,specifications and conditions are satisfactory and hereby accepted. Thank you for your business. Check out our portfolio at www.perldnsrobfing.net r TOTAL � �}lo� w.� ahy g9'raa�ay,�-s rev- QKai� �c�vEv�a�t $26,800.00 n r�•z�+�,t7 s�o,.►�w1 dtap��t- - 1r 3�to.o c, �1,� Ac�� cepteAccepted Date I r FL State Certified CCCO42786 y�r, ktagpaIyw, �t a S i J It `i AW r xw Y 4 ` h a r ilk Ilk • . ... .. ..• .• . . .. .. . IROOF ASSEMBLIES AND ROOFTOP STRUCTIRES: • • • . • • . • -'a Flbrida:Bjj ding pdtti 5t6ldition (2014)High-V • ItyNiunicane�ZoneUniforn�er< Application Form.�Q� •SQ0ion A (General Information? CITY • ••• • • • • •• • Master Permit No. : :• @rocess No. A f% n, Contractor's Name pe QZj 1 c)�PIr coe-to Job Address 9 LD 9 01 �;r ROOF CATEGORY tt��/�w Slope 13 Mechanically Fastened Tile _b<#Aortar1Adhesive Set Tile R E C E I V E u ❑Asphaltic ❑ Metal Panel/Shingles; ❑ Wood Shingles/Shakes Shingles DEC 1 2011' ❑ Prescriptive BUR-RAS 150 "C)'GA5 rr ROOF TYPE 171 New Roof �erooflng Cl Recovering Ct Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF) loa3 s�' 225 y 5t= "RSI= Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections,roof drains,scuppers,overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly Identify dimensions of elevated pressure zones and location of parapets. ZU TR C1 £e j 1191 N � O ❑ W �- LL Uj f� 3 ¢Q Cc > G ❑ Ly 61a Z '-D L L'9t Q Lu V ❑ W O , Z d{ Z �# -� C7 ❑ n M z C3` L L Q a�7 U) v~i 15.32 NG 9'L j ROOF ASSEMBLIES AND ROOFTOP STRUCTURES < i Florida Building Code 5th Edition(2014) High-Velocity Hurricane Zone Uniform Permit Application Form. 1 1 1 Section C(Low Slope Application) Top Ply F ste7r/Bonding Material- Fill in specific roof assembly components and identify 5e iff 1 1 manufacturer Surfacing: !y 4 1 1 (If a component is not used,identify as'NA") Fastener Spacing for Anchor/Base Sheet Attachment: 1 System Manufacturer:©/ �_ 66 J4 C , Z 1 �. Field:�"oc @Lap,#Rows @�"oc 1 Product Approval No.: J 7 -1 o o .GI Perimeter:-(P--oc @ Lap,#Rows @_L"oc i 11 i Design Wind Pressures,From RAS 128 or Calculations: Comer:LJ 'oc @ Lap,#Rows—4-@,L"oc 1 1 Number of Fasteners Per Insulation Board: i 1 FieldI�L Perimeter.,:f 4L'• CCrner ••'i' • Max.Design Pressure._from the soecific product �• . •• • 1 approval system:_ �-- S�, <<j Illustrate Components Noted arldOSI 9tls as Applimble: 00000• 1 Woodblocking, Gutter, Edge T&"rtdtipn,Strippping,Flashin 1 1 Deck: Continuous Cleat,Cant Strip,Base Fleshing,Cewwarflashing, TO: 1 Type: p 1 UI-)c9 2 C1 Coping,Etc. •00000 •00006 _ 000 J Indicate: Mean Roof Height, Pq&"t kleight„aQight•of Bad;• •• 1 Gauge/Thickness: � Flashing, Component Material,Ott'aj�dt T ' esS•� r. r:. 1 I f � Type, Fastener Sp' r-Su- . acture its th r• 1 Slope: ! Z Y a Comply with RAS 11 an�d`ssfiapter . • ...q.:. Anchor/Bass Sheet&No.of Ply(s): f•- NQS e �C�- � e� � iC J,(,�,�� • • • �eo 60000 1141 4�0 • 1 Anchor/Base Sheet Fastener/Bonding Material: � I' v+ (r •• � 1 1 insulation Base LayerA6 f'Oa YI ;� ti� �- �,tiro s 6 �) 1 Base Insulation Size and Thickness: X '� 3 t Height Parapet �� S Fvu Base Insulation Fastener/Bonding Material: �� �'� $T4 A4 Q 1 1 1 Top Insulation Layer: T. Mean 1 i Top Insulation Size and Thickness: 'h_ �1 i i Top Insuloop F tenor/Bonding MRoof e>lal- . �,) 2 Height 1 �, Base Sheet(s)&No.of Ply(s):� �P � ✓ //�/ � � � ads � I Base Sheet Fastener/Bonding Material: j -1 c ��� 1 L� "Le C1 1 �"ej Ise I ,eCl Ply Sheet(s)&No.of Ply(s):_ .41 14 ; 1 Ply Sheet Fastener/ponding Material: 1 NA � 1 Top Ply: G I wp 061.2 �2 1 15.38 FLORIDA BUILDING CODE—BUILDING,Sth EDITION(2014) ' 8 t , i 1 1 1 Copyright to,or licensed by ICC(ALL RIGHTS RESERVED);accessed by Eliczer Palacio on Jun 8,2015 10:32:12 AM pursuant to License Agreement.No further reproductions authorized. t ROOF ASSEMBLIES AND ROOFTOP STRUCTURES i Florida Building Code 5th Edition(2014) High-Velocity Hurricane Zone Uniform Permit Application Form i 1 Section D(Steep Sloped Roof System) 1 ' 1 Roof System Manufacturer: Notice of Acceptance Number. !s-- 7— --OA 1 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): 1 P1: P1: — 42.1 PI: 1 1 1 Deck Type: 1 Type Underiayment: t 1 R f Slope: 1 12 Insulation: .� 1 Fire Barrier: N A .. .�.... Ridge Ventla 'on7 Fastener Type&Spacing: •• Adhesive Ty Ol 15 �qj ,��•s Type Cap heet: rj . Mean Roof Height: L$ Roof Covering: ,�.1� 'r 4 Type&Sizie Drip Edge: -1 41V , 1 1 1 FLORIDA BUILDING CODE—BUILDING,5th EDITION(2014) 15.39 I I 1 1 ' Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Eliezer Palacio on Jun 8.2D15 10:32:12 AM pursuant to License Agmernent.No further vWnductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES F �s Florida Building Code 5th Edition(2014) ,` 1 High-Velocity Hurricane Zone Uniform Permit Application Form. i i i Section E(Tile Calculations) 1 For Moment based the systems,choose either Method 1 or 2.Compare the values for M,with the values from Mt. if the hA,values 1 are greater than or equal to the M,values,for each area of the roof,than the the attachment method is acceptable. 1 Metho 1 "Moment�B�a�s�ed Tito*Calculations Per RAS 127" (P1:�•� x _ -Mg: 1(P i =M„ . Product Approval M, 1 (P2''/ . x =r -Mg�=M,, .D Product Approval M, 1 (P3'l' xA(J 0 -Mg.ZW=M Product Approval M, . . 1 Method 2"Simplified Tile Calculations Per Table Below" 1 Required Moment of Resistance(M)From Table Below Product Approval M, 1 M,required Moment Resistance' Mean Roof Height 1 Roof Slope 15' 20' 25' 30' 40' 1 2:12 34.4 36.5 38.2 39.7 42.2 • 1 3:12 32.2 34.4 36.0 37.4 • 36.8 """ 1 4:12 30.4 32.2 33.8 35.1 0�0J.3 ••�• ������ 4 1 5:12 28.4 30.1 31.6 32.8 ....3A.9 1 6:12 26.4 28.0 29.4 30.5 0••932.4 •••� 1 7:12 24.4 25.9 1 27.1 1 28.2 ""30.0 "' ••••• 1 'Must be used in conjunction with a list of moment based the systems endorsed by the Broward rkoLpty'Board of,Rtwt;s and,,,,:, Appeals. ...... • For Uplift based file systems use Method 3.Compared the values for F with the values for Fr.If the�'values are gr6ateo nth an or....:. 1 equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. • . ...... 1 Method 3'Uplift Based Tile Calculations Per RAS 127" •� ��•• (P1:_x L = x w:=_)-W: x cos 6_=F„ Product Approval F' p 1 (P2: x L = x w:=�)-W: x cos 8 =Fn_ Product Approval P i (P3:_x L^= x w:=,)-W: x Cos A =F„_ Product Approval F' i 1 Where to Obtain Information 1 Description Symbol Where to find 1 Design Pressure Pt or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by P b 1 Mean Roof Height H Job Site 1 Roof Slope 0 Job Site 1 Aerodynamic Multiplier x Product Approval 1 Restoring Moment due to Gravity M9 Product Approval 1 Attachment Resistance Mt Product Approval 1 Required Moment ResistanceMo Calculated I Minimum Attachment Resistance F' Product Approval f 1 Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval I Tile Dimensions L =length W=width Product Approval 1 All calculations must be submitted to the building official at the time of permit application. 1 15.40 FLORIDA BUILDING CODE-BUILDING,5th EDITION(2014) I / 1 1 1 1 Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED).aocused by Eliettr Palado on Jun 8,201 S 10:32:12 AM pursuant to License Agtcetnent.No furdw tcptodualom authoniM. w SECTION 1524 HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope.As it pertains to the section,4 is the responsibility of roofing contractor to provide the owner with the required roofing permit;and to explain to the owner the content of the section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations.Additionally,the a following items should be addressed as part.of the agreement between the owner ant the contractor.The owner's initial in the designated space indicates,that.the item has been explained. Renailing wood decks:When replacing roofing,the existing wood roof deck may have to renailed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system). " •---4+---- KA Exposed Ceiling:Exposed,open beam ceilings are where the undemide of the Qoof decking ed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail penetration of the underside of the decking may not be acceptable.•Tttis�prgvides lie option of • maintaining the appearance. •••• sees' s s e e s . . sees.. ... sees. •i •e •• eieeee / �-- Overflow scuppers(wall outlets):It is required that rainwater floM'oI'sb that the r8of is. not overloaded from a buildup of water.Perimetededge wall or other roof extension may block this:• """ discharge if overflow scuppers(wall outlets)are not provided. It ay be neces• �ipstall oygrflow :see• scuppers in accordance with the requirements of Sections R 2, 4403 an R 1 • gent's ' nature Date Contra or Signature Date ZQ co Ne 9 9 S-Tr Propeo Address Permit Number Revised on 7/9/2009 LD;07/01/2015; C ' MIAMI, MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 { BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA,Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,themanufacturer will incur the ekpense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to Owgbe ... requirements of the applicable building code. : .•. • ... This product is approved as described herein,and has been designed to comply with the Flq> �� uildin.y Co • including the High Velocity Hurricane Zone of the Florida Building Code. so*:** • .... .... . . DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks "'• •••• ••••• ...... ... . ..... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,. 4.state and following • statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. • : . . ....:. RENEWAL of this NOA shall be considered after a renewal application has been filed and•tltere has been.no chance ' in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 13-1217.01 and consists of pages 1 through 34. The submitted documentation was reviewed by Alex Tigera. CMLAMMADEcouNTY NOA No.: 17-1004.09 - . Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 1 of 34 i ROOFING ASSEMBLY APPROVAL Cam Roofing Sub-Catesory: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastobase 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I base sheet. XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type I base sheet. Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet Type II 0 • .6096. 9 6666.. Polyanchor 250' x 48" ASTM D 4601 A polymer woven,high pelfQAnince,gpthetic base • Type II sheet. •••••• .. Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coate� • 1 ester reinforced b6 . .4s 9 i y 9999 Typel sheet. 96c696 •6606• ease* Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fibr;uMs reinfdi' (t SBS••:•• 6 (1.5-mm) Type 1 modified bitumen membran6e w66ith a self-adhering MIR% 6666.. face and a smooth top su*ce: ; 0 6 6 969096 Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,%erg%s reirfforced, SBS:.... PLUS FR Type I modified bitumen membrane wifh a self-Idhdring lack • face and a smooth top surface. 00 Elastoflex SA V(1.5- 66' 8"x 3' 3_3/811 ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified mm) Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified PLUS Type I bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified SA Type 1 bitumen membrane with a self-adhering back face and a smooth top surface. F Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered, fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. NOA No.: 17-1004.09 MuaraFw�e CO=UNTYExpiration Date: 10/11/22 Approval Date: 10/12/17 Page 2 of 34 a " F Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and ' a granule top surface. Polyflex 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex SA P 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced, APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered, fire-rated,po'lyeder reinforced,APP "'•;• Type I modified bitumen membrajj..wjtb a sek-adliering back. . . ...... face and a granule top surfj"' . XtraFlex APP G SA 32' 10"x 3' 3_3/8,' ASTM D 6222, Self-adhered, fire-rated,pQI�W x reinf,0*rW.APP • • Type I modified bitumen membrane with a self adhering b'a�S". face and a granule top surwe.. • .. ...... Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered, fiberglass relflf t:d, SBS modified •, Type 1 bitumen membrane with a self-a$herin$.backface M(f••• a granule top surface. • • . .'• :•... Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered,fire-rated, fiberglass reinforce;, SBS FR Type l modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified Type l bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type l bitumen membrane with a self.-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 33/8" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type 1 base sheet. NOA No.: 17-1004.09 MIAMFGADE COUNTY Ex iration Date: 10/11/22 �Fj...* P Approval Date: 10/12/17 Page 3 of 34 PG325 Cold Process 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. � r PG1 90 Asphalt Primer 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 1.7 oz. spray selected asphalts used to promote adhesion. can XtraFlex 10 Asphalt 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of Primer tube or 17 oz. spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type III modified bitumen membranes. ,PG400 Plastic Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement. Cement tube , PG500 MB Flashing .1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use Cement tube with modified bitumen mgmbr4nes. •••••• Polyplus 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adheside designeolfor%se with •� Mod Bit Adhesive tube Type III modified bitumen membranes" •••••• ...... XtraFlex 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed-Zr use wiV Mod Bit Adhesive tube Type III modified bitumen membranev. • •000* • ••••• .. . Polyplus 45 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 'A thick,fibered,rubberized4fl....oVh ce.m.. ..... eVb •• • ' Flashing Cement tube ...... .• Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing ckwid .for usls• MB Flashing Cement tube with modified bitumen mtplbrapes. •••• XtraFlex 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cemerrKor use Modified Wet/Dry tube with modified bitumen membranes. Cement Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement NOA No.: 17-1004,09 ML4kMFQADE couNnr Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 4 of 34 "APPROVED INSULATIONS: 2} TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation ftax OpCPati1hr,LLC...... SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard "United Stag Gypsum • • ••• Corporation .... .... . . .. .. .. ...... . . . . ...... i I F e \ i NOA No.: 17-1004.09 MAMM we COunrrir Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 5 of 34 1 # 'APPRbVED FASTENERS: ! TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) I 1. Dekfast Fasteners 12, 14& Insulation fastener for wood, SFS Intec,Inc. 15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2'/s"x SFS Intec,Inc. Hex Plate 31/413 3. 414 Roofgrip Insulation and membrane Various OMG,Inc. fastener f 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG,Inc. 5. Trufast#14 HD Fastener Insulation fastener for steel and Altenloh,Brinck&Co. wood decks U.S.,Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co. Plate plate 3" round U.S.,Inc. 7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various •Polyklaas.U3A, Inc •••••  steel and concrete decks • 8. Polygrip Hex Plates Galvalume hex stress plate. 2'/8" x •••;•Polyglass OSA, Ino••• • ..... .... . .... . . .... .... ..... . ...... ... . ..... .. .. .. ...... . . . . ...... i d a NOA No.: 17-1004.09 rnartFo�e c0UNTY Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 6 of 34 'APPROVED SURFACING: r TABLE 4 Product Product ApplicationSpecification Manufactur , Name. Description Rate er PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1'/z-2 gal/sq TAS 140 Polyglass to add life and rejuvenate existing USA,Inc. BUR roofing substrates. XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used 1'/2-2 gal/sq TAS 140 Polyglass Coating to add life and rejuvenate existing USA,Inc. BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof 1'/z-2 gal/sq ASTM D4479 Polyglass coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR XtraFlex Bituminous.Roof An asphalt cutback fibered roof I'/z-2 gal/sq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged • BUR ...... PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. ''/2-1 gal/sq t>< MT 2824 •.polyglass..:. Roof Coating ••4lpe I •USA,Imc. •• PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 1'/z-2 al/sq AS•••-D2824••• dolyg1 tTu as... Coating ..TF4e III ,..• IDSA, Inc;..• PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/z gal/sq I JM D6083 �olyglYs•0 based roof coating(water-based). A 0 a USA Inc. • polyester fabric may be used for •••••• ...... reinforcement with this coating. ••• .,.. . PG800 Non-Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM 131227 •`)solyglass Emulsion Roof Coating emulsion two coats USA,Inc. XtraFlex 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227, Polyglass Coating emulsion two coats USA,Inc. PG850 Fibered Asphalt Emulsion An asphalt base, fibered clay 3 gal/sq in ASTM D1227 Polyglass Roof Coating emulsion two coats USA,Inc. Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 Polyglass Aluminum Roof Coating Type III USA,Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 Polyglass Coating.Fibered Type III USA,Inc. Polyplus 60 Premium Non- Non-fibered aluminum roof coating. '/2-1 gal/sq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA, Inc. XtraFlex 60 Aluminum Roof Non-fibered aluminum roof coating. '/2-1 gal/sq ASTM D2824 Polyglass Coating Type I USA, Inc. NOA No.: 17-1004.09 htuEUApe CouNr�r Expiration Date: 10%11%22 Approval Date10/12/17 Page 7 of 34 I APPROVED SURFACING: TABLE 4 f Product Product Application Specification' Manufactur Name Description Rate er Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/z gal/sq ASTM D6083 Polyglass Elastomeric Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 Polyglass Roof Coating based roof coating(water-based). A USA, Inc. polyester fabric may be used for reinforcement with this coating. Polybrite 90 High Solids Silicone A premium grade high solids, single 1.25 gal/sq ASTM D6694 Polyglass Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids, single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating • Polybrite 95 Silicone Roof A single component, solvent, 1.25 gal/sq �$T4P6694• Polyglass**:" Coating moisture cure silicone coating. .goose 'e JYSA,Iqq....:. XtraFlex SRC 8000 Silicone Roof A single component, solvent, 1.25 gal/sq A94$'D6694 6 Polygl*s...: Coating moisture cure silicone coating. •••..• 'o.01;SA,Inc.• Gravel To be installed in a flood coat of 4001bs/sq •• -NAA •'••• f enerio:g approved asphalt at 60 lbs/sq •• •' •••••• .geese • Slag To be installed in a flood coat of 3001bs/sq *N:A .Generjj••:s approved asphalt at 601bs/sq :00000 0 0 000 0. .0006. NOA No.: 17-1004.09 MuuhMADE COUNTYExpiration Date: 10/11/22 Approval Date: 10/12/17 Page 8 of 34 f 'EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3001334 02.15.00 4470 3000857 01.12.00 4470 3004091 01.12.00 4470 3012321 07.29.07 4450, 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 r 06.02.04 TAS 114 P1734.07.06-R1 02.27.07 TAS 114 P1738.02.07. ;'(12.05.07 •••••� TAS 114 P1739.01.07*. .'.01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.0670•:•• f MAX 0000:0 ASTM D6164/ASTM D6222 P10490.08.0900000 OR.13.08 :0,00: ASTM D6164/ASTM D6222 P10490.10.08-00*0- .0M.W.08 ' . ASTM D6222 P7400.03.08-1"000.... .'. 9.08:161 "0:00- 0000. TAS 114(D)—ASTM D1876 P10070.10.0$.'..' lah.08 ASTM D6222 P 10490.10.08.2---. 10.30.08 FM 4470&TAS 11.4 P33970.03.1; •..0.45.11 -.-.:. . .. ASTM D6163 /ASTM D 4601 P33960.03.1 t • 03.15.11 :, 0: TAS 114&TAS 117(B) 11757.12.00-1-1;tf ' "64.Z.13 ' - TAS 114&TAS 117(B) 11757.04.01-1-R1 04.030.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6163 P37590.03.13-27R1 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 /TAS 117 P45940.09.13 09.04.13 TAS 114&FM 4474 P41630.08.13 08.06.13 TAS 114(H) P13760.09.09 09.10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 a 05.16.14 NOA No.: 17-1004.09 Mu�tMa4necouNTY Expiration'Date: 10/11/22 Approval Date: 10/12/17 Page 9 of 34 { x Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24"spans with#8 wood screws at 6"o.c. System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 Any,approved Polyisocyanurate listed in Table 2 Minimum 1"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 ••• :density/ft:..... Fesco Board . 0000.. Minimum 3/0"thick N/A .N/A 0000.. 0000 0000 . . Approved High Density Wood Fiberboard 0000 66.. ..606 Minimum '/2"thick N/A 6.6. 1:1/A ••••• .. .. 66 00.0.0 DensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof Board • . . . . Minimum 1/4"thick N/A ;••••N/A 00000 . . .0606. Note: All insulation shall have preliminary attachment, prior to the installation of the roofing memb;ane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase,XtraFlex SBS Glass Base,Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast 14 with Dekfast Galvalume Steel Hex Plates,Polygrip Fasteners#14 with Polygrip Hex Plates or Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates spaced 12"o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V(1.5-mm),Elastoflex SA V PLUS,XtraFlex SBS Base SA,Elastoflex SA V FR(1.5-mm)or Elastoflex SA V PLUS FR, self-adhered. F NOA No.: 17-1004.09 Muuhi•oa�e couNrir Expiration Date: 10/11/22 ® Approval Date: 10/12/17 Page 22 of 34 F Membxane: One ply of Polyfresko G SBS SA,Polyfresko G SBS SA FR,Polyfresko G APP'SA, Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. -� Maximum Design Pressure: -52.5 psf, (See General limitation#7.) 0000.. 0000.. 0000.. . 009090 0000 0000 . 0000 0000 00000 0000.. ... . 00000 99 99 .. 0900*0 0000.. 0000.. 9 900 0 NOA No.: 17-1004.09 M� �•oan�couNnr Expiration Date: 10/11/22 Approval Date: 10/12/17 Page^23 of'34 WOOD DECK SYSTEM LIMITATIONS: 1. ,A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance;'refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. ;•090• 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force{f�value of.27S lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,*al field-tented;ere below..:. 275 lbf. insulation attachment shall not be acceptable. ""'• • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment N based,8A VminimQm • fastener resistance value in conjunction with the maximum design value listed within g�SpVjjfic system*Should*:**. the fastener resistance be less than that required,as determined by the Building OfficiaL%r.&ised faste0Cr .... spacing,prepared,signed and sealed by a Florida registered Professional Engineer,Rested Architect,or .• Registered Roof Consultant may be submitted. Said revised fastener spacing shall utieze the withdrawal ....% resistance value taken from Testing Application Standards TAS 105 and calculations:n c9ftlianct with RoofM Application Standard RAS 117. 7. Perimeter and corner areas shall cothply with the enhanced uplift pressure requirements of these areas Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE i MwhiFa4oe couNrir NOA No.: 17-1004.09 1 ...� Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 34 of 34 TGFU.R14571 -Roofing Systems Page 5 of 15 Baso Sheat:—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),mechanically fastened or"ELASMR.EX SA V PLUS FR", "ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT"(self adhered). Ply Sheet(Optional):—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),heat fused or mechanically fastened,or'ELASTOFLEX SA V PLUS FR','ELASTOFLEX SA V FR'or"ELASTOFLEX SA V FR BASE VENT%(self adhered). Membrane:—"POLYFLEX SA P FR",'POLYFRESKO G APP SA P FR',"ELASTOFLEX SA P FRI,'POLYFRESKO G SBS SA P FR", "ELASTOFLEX SA V FR HI',(self adhered)or"POLYFLEX G FR","XtraFlex APP G HP",'Xtraflex APP G FR',"POLYFRESKO G FR",'DUFLEX G FR","XtraFlex APP Dual","ELASTOFLEX S6 G FR","POLYFRESKO G SBS FR","ELASTOFLEX VG FR',"XtreFlex SBS POLY G', XtraFlex SBS POLY G T",'XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or'ELASTOSHIELD TS G FR",heat fused. Dock-C-15/32 Incline:1/2 Insulation(Optional):—Polylsocyanurate 1.5 in.(min.)with all joints staggeied 6-4n.(min.)from the plywood joints. Base SheeC—Type G2,mechanically fastened followed by` ,"XtraFlex SBS GLASS Base",mechanically fastened. Mff Ply Sheet(Optional):—"ELASTOFLE)(SA V PLUS FR','E "or"ELASTOFLEX SA V FR BASE VENT',(self adhered). Membrane:—'POLYFLEX SA P FR","POLYFRESKO G APP P FR",'ELASTOFLEX SA P FR',"POLYFRESKO G SBS SA P FR",or"DUFLEX G FR FR I,"XtraFlex APP Dual","POLYFLEX G ",'XtraFlex APP G HP"," OFLEX S6 G FR','POLYFRESKO G SBS FR",'ELASTOFLEX VG FR','XtraFlex SBS POLY G","XtraFlex SBS POLY G T",'XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or "ELASTOSHIELD TS G FR',heat fused. 23.[leek:NC Indine:2 Insulation(Optional):—'Polythene",Atlas Roofing"ACFoam III"or"ACFoam II'or Hunter Panels"H-Shield",any thickness. Base Sheet:—'ELASTOBASE",'XtraFlex SBS GLASS Base"(poly/sand),heat fused or mechanically fastened or"ELASTOFLEX SA V FR", 'ELASTOFLEX SA V PLUS FR'or"ELASTOFLEX SA V FR BASE VENT',(self adhered). Membrana:—'POLYFLEX SA P FR","POLYFRESKO G APP SA P FR","ELASTOFLEX SA P FR",'POLYFRESKO G SBS SA P FR', "ELASTOFLEX SA V FR HT',(self adhered)or"POLYFLEX G FR","XtraFlex APP G HP','Xtraflex APP G FR";"POLYFRESKO G FR',"XtraFlex APP Dual",'DUFLEX G FR','ELASTOFLEX S6 G FR',"POLYFRESKO G SBS FR•,"ELASTOFLEX VG FR','XtraFlex SBS POLY G",'XtraFlex SBS POLY G T','XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or"ELASTOSHIELD TS G FR',heat fused. 24.Deck C-15/32 Indira:3 Insulation(Opt(Optional):—Polyisocyanurate,perfite,wood fiber or PoI i Yanurate/perlite board,any thickness. ••••• r • • • Barrier Board:—1/4 In.(min)G-P Gypsum DensDeck®,mechanically fastened with all joints staggered 6 In.from the plywpoWoints. •••••• Base Shoat:—"ELASTOBASE',"XtraFlex SBS GLASS Base'(poly/sand),mechanically fastened. •• • •• • • • Ply Sheet(Optional):—'ELASTOFLEX SA V PLUS FR',"ELASTOFLEX SA V FR'or"ELASTOFl.EX SA V FR BASE VENT" red). m •••• •••• • Mebrana:—"ELASTOFLEX S6 G FR','XtraFIex SBS POLY G","XtraFlex SBS POLY G T or'POLYFRESKO G SBS FR",�iea 25.DeciaNC Incline:3 •••• •••• i••••: Insulation(Optional):—'Polythene",Atlas Roofing'ACFoam III"or"ACFoam II"or Hunter Panels'H-Shield',any thllkf185l. ••i• ••••• Be"Sheab—'ELASTOFLEX SA V PLUS FR',"ELASTOFLEX SA V FR'or'ELASTOFLEX SA V FR BASE VENT"(self adheted3 t • • Membrana•.—"POLYFLEX SA P FR",'POLYFRESKO G APP SA P FR iif"ELASTOFLEX SA P FR"or"POLYFRESKO G SBS SA P ER • ... • ••••• f adhered). •• •• •• •••••• 26.Deck NC Indlne,.1/2 • • • • •• Base Shoat: Type GI or G2,mechanically fastened. •••••• i Membrana:—"POLYFLEX G",'XtraFlex APP G HP TOR",'Xtraflex APP G'or'POLYBOND G",heat fused. . ••• • • • 27.Dedc NC Indlne:3 •• Membrana:—'POLYFLEX SA P FR',"POLYFRESKO G APP SA P FR","POLYFRESKO G SBS SA P FR'or"ELASTOREX SA P FR"(self adhered). t 28.Deck:NC Incline:1 Insulation(Optional):—Polyisocyanurate,any thickness. Baso Sheet(Optional):—'ELASTOFLEX SA V","ELASTOFLEX SA V PLUS",-Xtraflex SBS Base SA"or"ELASTOFLEX SA V BASE VENT% self-adhered or"ELASTOBASE',"XtraFlex SBS GLASS Base'(poly/sand),,mechanically fastened. Membrane:—"POLYFLEX SA P',"Xtraflex APP G SA"'XtraFlex Kool APP G SA",or'POLYFRESKO G APP SA P'self-adhered or"POLYFLEX G FR",heat fused. 29.Dock-C-15/32 Incline:1/2 Insulation:—Polylsocyanurete(2 in.min),glass fiber(15/16 in.min),perlite/polylsocyanurate composite,perlite/urethane composite (21n.min). Barrier Board:—1/4 In.,(min)G-P Gypsum DensDeelk®,mechanically fastened,with 6 in.offset to plywood joints. Bass Sheat:—'ELASTOFLEX S6","XtraFtex SBS POLY Base","ELASTOFLEX P-C"(heat fused.or mechanically fastened). Membrane:—'ELASTOFLEX S6 G",-ELASTOFLEX S6 G-C"or'POLYFRESKO G SBS",(heat fused). 30.Oeda NC Incline:1/2 Insulation(Optimal)—"Polytherm",Atlas Roofing"ACFoam III"or'ACFoam II",any thickness. Baso Sheet:—"ELASTOFLEX SA V PLUS FR','ELASTOFLEX SA V FR"or"ELASTOFLEx SA V FR BASE VENT',(self adhered). Membrana:—'POLYKOOL SA"or"XtroKool APP S SA",(self adhered). i t 31.Dedc 5/32 Incline:1/2 Base Sheet:—G2 Base sheet mechanically fastened followed by'ELASTOFLEX SA V PLUS FR","ELASMFLEX SA V FR"or'ELASTOFt.EX SA V FR BASE VENT",(self adhered). Membrane:—"POLYKOOL SA"or"XtraKool APP S SA",(self adhered). t http://&tabase.ul.com/cgi-bhVXYV/template/LISEXT/IFRAME/showpage.html?name=T... 10/5/2017 MIAMI-DADS COUNTY MIAMI PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Floiida 33175-2474 BOARD AND CODE ADINllNISTRATION DIVISION T(786)315.2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) w�vw.minmidade.eov/c nomv Entegra Roof Tile,LLC 1289 NE 91h Ave Okeechobee,FL 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acoe6ptance, 6666. if it is determined by Miami-Dade County Product Control Section that this product or;material fails to meet the*•••. requirements of the applicable building code. : • This product is approved as described herein, and has been designed to comply with tlaa Florida Building Corte including the High Velocity Hurricane Zone of the Florida Building Code. •••• ••6• :"": 6666 6666 6666. DESCRIPTION: Plantation Roof Tile • .. .. .. 6666.. 6666;6 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Citi, stat Band followin§0 0 0 6 6 .. statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein 0 0 . . 666666 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been as change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or,change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#14-1120.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. I NOA No.: 15-0721.04 MFAMMMECOUINMY Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 1 of 7 'ROOFING ASSEMBLY APPROVAL P rr Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Plantation Tile Length: 16%2" TAS 112 Flat concrete roof tile for direct deck or Width: 13" battened nail-on,mortar or adhesive set applications. Trim Pieces L=varies TAS 112 Accessory trim,concrete roof pieces for W=varies use at h ips,rakes,ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION •••••• 1. Okeechobee,FL ...... . .. ...... 2.2 SUBMITTED EVIDENCE: •••• •••• • .... .. ..... Test Agency Test Identifier Test Name/Rep •• ••Nate_ American Test Lab of South RT0624.05-14 TAS 112 ••••• 07i/14 ...... Florida • . . . ....:. Redland Technologies 7161-03 Static Uplift Testing . ;•Hee X1991 , • Appendix III PA 102&PA 102tA)0 .o o . :••'•; The Center for Applied 94-060B Static Uplift Testing MA613, 1994 Engineering,Inc. 94-084 PA 101 (Adhesive Set) May 1994 (Mortar Set) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix I1 PA 108(Nail-On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108(Nail-On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108(Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs.smooth shank nails The Center for Applied Project No.307025 Wind Driven Rain Oct. 1994 Engineering,Inc. Test#MDC-76 PA 100 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 April 1999 Walker Engineering,Inc. Calculations 25-7183 March 1995 25-7094 February 1996 25-7496 April 1996 NOA No.: 15-0721.04 MIAMWADECou111Y Expiration Date:12/08/20 �LAWU' Approval Date: 11/05/15 Page 2 of 7 2.2 SUBMITTED EVIDENCE: Test Anencv Test Identifier Test Name/Reuort Date Walker Engineering,Inc. Calculations 25-7584 December 1996 25-7804b-8 25-7804-4&5 25-7848-6 Walker Engineering,Inc. Calculations Two Patty Adhesive Set System April 1999 Farabaugh Engineering and T295-11 TAS-108 10/05/11 Testing Inc. Farabaugh Engineering and T306-11 TAS-108 10/04/11 Testing Inc. Farabaugh Engineering and T279-11 TAS-108 '09/23/11 Testing Inc. 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. ! 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified LaboratojJ9 perform gyartprly testi••,:• in accordance with TAS 112, appendix `A'. Such testing shall be submitted to."Miami-pads jtoduct••••;• Control office for review. see:** 3.4 Minimum underlayment shall be in compliance with the applicable Roofmg ApprLliApns Stwtd'aTd$ listed • section 4.1 herein. .... ....• .... 3.5 30/90 hot mopped underlyYnient applications may be installed perpendicular to ft*4pof slopeunit �state ••••. . otherwise by the underlayment material manufacturers published literature. ...... •• 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be•in coppjippge with***:* applicable building code. • 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida-wilding • Code and Rule 61020-3 of the Florida Administrative Code. NOA No.:15-0721.04 MAMI-OMECOWO Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 3 oil 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W) and Dimensions(I x w) Tile Profile Weight-W(Ibf) Length-1 (ft) Width-w(ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers -X(0) Tile A.(ft3) X(ft3) Profile Batten Application Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity-M (ft-Ibf) E greater than 2": 12 3": 12" 4": 12" 5": 12" 6">12". :*7"12" .. ... Battens Direct Battens Direct Battens Direct Battens Direct Battens irsct Battens Direct Deck Deck Deck Deck •Deck Deck. .:. 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44• e32 6.26 7.04 .. ... ••• •••• • ...... ... . ..... I NOA No.:15-0721.04 MIahtMD£COUNmr Expiration Date:12/08/20 Approval Date: 11/05/15 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment-Mr(ft-lbf) For Nall-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 15132" (Min. 19/32" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2#8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail • Eave Clip) �'• • • ••:• 2-10d Smooth or 35.5 35.5 •� ••• '�•• •��• Screw Shank Nails 000• Field Clip) •• Goes •••• 2-10d Smooth or 31.9 31.9 000 322. 000 Screw Shank Nails •• ••• ••• • . ••. Eave Clip) " •• •• •••• 2-10d Ring Shank 50.3 65.5 •••• Nails' • •o•; 1 Installation with a 4"tle headiap and fasteners are located a minimum of 2'/a"from the head of tile. •• 0 •"• : ' Table 5: Attachment Resistance Expressed as a Moment Mf(ft-Ibf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 31.33 2 See manufactures component approval for installation requirements, 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. 3M'2-Component Foam Roof Tile Adhesive AH-160.Average weight pera 8 rams. Table 6: Attac t Resistance E a Moment-Mf(ft-Ibf) For Single Patty Adhesive Set Systems Tile Profile cation i minimum Attachment'Resistance Plantation Tile 3M'2-Component Foam Roof Tile Adhesive AH-160 118.94 3M" 2-Component Foam Roof Tile Adhesive AH-160 40.45 4 La a addy placement of 45 grams of 3M'"2-Component Foam Roof Tile Adhesive AH-160 -�. 5 Medium addy placement of 24 grams of 3M"'2-Component Foam Roof Tile Adhesive AH-160. NOA No.: 15-0721.04 M I•DADE COUNTYAR Expiration Date:12/08/20 Approval Date: 11/05/15 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Seespecific mortar manufacturer's Notice of Acceptance. 5. LABELING l All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami-Dade County Product Control Approved". OR ENTEGRA ...... ... . ..... .. .. .. ...... PLANTATION ROOF TILE LABEL(LOCATED ON UNDERSIDE ffORF) • 6. BUILDING PERMIT REQUIREMENTS: ...... 6.1 Application for building permit shall be accompanied by copies of the following: •.: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 15-0721.04 MIAMMADHCOUNTY�LWXExpiration Date:1210=0 Approval Date: 11/05/15 Page 6 of 7 PROFILE DRAWING PLANTATION FLAT CONCRETE TILE 16Ii2,, .... .... . . .... .... ..... ...... ... . ..... .. .. .. ...... END OF THIS ACCEPTANCE MIAMIMDE c DUNW NOA No.: 15-0721.04 .z •, , Expiration Date: 12/UM Approval Date: 11/05/15 Page 7 of 7 .MI� MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy ICP Adhesives and Sealants,Inc. 12505 NW 44'Street Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediate) revoke•modify, ••• p g y ' y � � , or suspend the use•�• of such product or material within their jurisdiction. RER reserves the right to revokee this acqptantp, if it is• determined by Miami-Dade County Product Control Section that this product or material Mils'13 Ineet tine t' 4uiremeltM*•• of the applicable building code. 0:0000 0• :0066 This product is approved as described herein, and has been designed to comply with•t��orida Bail ing Code•.• including the High Velocity Hurricane Zone of the Florida Building Code. •••••• ••• 06:99 •• •• .. 0000.. 0000.. DESCRIPTION: ICP Adhesives Polysee AH-160 •••• • 0000.. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo' cify, state Aad:follovring statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. 0• RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. ,*Kvw NOA No.: 17-0322.03 MIAMFDAD'COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 t, ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc. as described in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by'applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP Adhesives Polyset®AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications + ICP Adhesives N/A TAS 101 Two component polyurethane fd&ft;2tdhesjLvA • Polyset'AH-160 ' .... . *000 ••••. ICP Adhesives Foam N/A Dispensing Equipme•t ••�•• • Dispenser RTF1000 •••••.• .... .... . ICP Adhesives ProPack® N/A Dispensing Equipment••• •••• 00000 ...... ... . ..... 30& 100 ' .. .. .. ...... . . . ...... PRODUCTS MANUFACTURED BY OTHERS: . Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NUA which list'attAhment resistance values with the use of ICP Adhesives Polyset' AH-160 roof tile adhesive. 00 MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Prope Test Results Density ASTM D 1622 1.6 lbs./ft.' Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMFDADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 l { EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 �1/16✓95 0000. 0000.. Trinity Engineering 7050.02.96-1 TAS 11.4 03 614/86 ••• • P36700.04.12 ASTM D 1623b4/1$/12 P39740.02.12 TAS 101 •*000 O;aV12 TAS 123 .•••• 09.09. Celotex Corp. Testing Services 528454-2-1 TAS 101 •• ••• 10/IA8 •••••• 528454-9-1 •'•••• •� 528454-10-I 0000.. 520109-1 TAS 101 •0• 12/28/98 :0000: 520109-2 • 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset" AH-160 shall solely be used with flat, low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 MLAMDAoe C01 Expiration bate: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 ' INSTALLATION: 1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset®AH-160. 2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B" component shall be mainVjVgd petween 1.0-1.15 (A): 1.0(B). 0 0 0000.. 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam DispensariR &000 or tCP' Adhesives ProPack®30& 100 dispensing equipment only. 990:66 • 0000.. 00000000 . . 7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight. •0*0 0• •0000• •••• 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minae'after ICAAge,;ives ••%•• 66 06 00 0000.. Polyset®AH-160 has been dispensed. 0 000000 0 0 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in actordarice with the. 0 0 00%. 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. 0•000.. • foe 0 .0600. NOA No.: 17-0322.03 MMMADe COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile • Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High Profiles All Eave Course 17-23 sq.inches 45-65 Flat,Low,High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each• 060 bead • Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches :;,14 grams t}nder p ••• .... .... . . LABELING• """ "• '••'• All approved products listed herein shall be labeled and shall bear the imprint or identifiable masw4og of the . manufacturer's name or logo and following statement: "Miami-Dade County Product Contro;Approved"4or the Mian-e••:• 'Dade County Product Control Seal as shown below. • hEili[i1�AE]E Ct]tJh(lY '•i •s a BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 MIAMFtaADE couNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# 1 Mad throughplastic-c"ont PaddylBo ambri e) Flat/Low Profile Tile 55 f' r' 1� tfedrduymr^ y-xa �E� ..,• °1 '� 1. Starting at the eave course,apply a minimum 2" 1 , ,ti.Y (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the Overlock ••, 101n`�..� t`�. `-, ``�•�,�' ti of the tile being set. IN l)•atuns op6ona1 E~Courts. a`r y� 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. f fir 4 � clusum Medium Profile/ Doubleraq Wjle •••••• Nail through ptasik cement •• • •"• • •' lwhen re(pired) • • • • 000 Ndoillonrwthr4ol 1. Starting at the eave coulge,•ftly a tllinHum 2 50.8 mm x 10" 254 mm*x 1" 25 .4 mm foarri 000*: �'�`�. '`•,�z ', �.� ° paddy onto the underlay***positiegjjshow#%O•• -•. •ti. ° � .�''•'`��., under the an portion a clo to he • P P at'il�e ril S�.St t ..... overlock of the tile being'sa1;' '.: 000000 �� ``_;. '•_ �,5l,. 2. Continue in same manner. Infare a atel •ldi e% Battens optional i �� y 1 r' �., �'4�'' f- (109.7 cm2)—23 (148.4 cm).square inch adhesite...; —*,, ;` .�`¢r`.y� w`• �f, r P r'f contact with the undersi3e Of1he tile: E3nreclosure tar-Course- ,. Fascia N l[hceuO plwctic crf)w"r,. Hi h Profile/Single Pan Tile (When requlra+d} Padrttr l$rnrrth7ilw} g .� -+..+ ��{ Vndrlwymw�twU` ` 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam +I •r _"' �, {Ek paddy onto the underlayment positioned as shown toiw.= under the pan portion of the tile closest to the 4 1n''"'"1 overlock of the the being set. Ba[tcns .� ., `''• i %` .• ' 2. Continue in same manner. Insure approximately 17 ° 0",' (109.7 CM2)—23 148.4 cm2 square inch adhesive contact with the underside of the tile. � Eave Course-.�;� � �• ,,,��•• Fascia 10 in�4 )iw. f —+ /� Emt[lostme '+�. .-I'r f f' �17rlpedgt NOA No.: 17-0322.03 MIAMF[aADE COUNTY Expiration Date: 05/10/22 CO=UNTY Approval Date: 04/27/17 Page 6 of 11 i 1 ADHESIVE PLACEMENT DETAIL#2 ` •` NAR 11hraugh pla+lic€«m.nt Paddy OS•n•alhTD.l Flat/Low Profile Tile (when re golrad), w 1 t UnclQdaynt4mt t U r s"•10 S�, 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the ^R, � .j• "� strengthening rib of the tile closest to the overlook of M. `. �� S w .� the the being set. Insure approximately 17(109.7 cm2) —23 (148.4 cm2)square inch adhesive contact with the 6attauaeDt7enal '+ �� w�,`'• iavaCourse f'<< underside of the tile. 2. At the second course apply a minimum 2" 50.8mm I - j'r_ := :da x 7 (177.8 mm)x 1 (25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile cave closure being set. 3. Continue in same manner.Insure appro:44V:ely 10" (64.5 cm2)- 12(77.4 cm2)lquafe.inch ddhesive contact with the underside orthe tile. •• • .... .... . . Nail tErrough plastic cement Medium Profile/Double Pari U6• 0000•' ..... I • • (whenrequiredf •••••• ••• • ••••• 1. Starting at the eave course,* a minimurrvT' 50!8•••• �. `-•,� �_,-PaddylBcn•athYllej: $ � Pl�IJ ( • mm)x 10"(254 mm)x 1"Z25:f Cnm)foam'paddy • Undwrlryn•ne��� �'•.� • • •• ••• onto the underlayment posi•tioned as shoKin Ander the • pan portion of the tile closgt to tpe ov.*dock of the •..... tile being set. Insure approximately 17(109.rcm )— In. 23 (148.4 cm2)square inch adhesive contact with the ` .. h Battens Optional , � r underside of the tile. , �� x�,. 2. At the second course,apply a minimum 2"(50.8mm) r x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the .\ Ea"GOIL r• ; underlayment positioned as shown under the pan r portion of the the closest to the overlock of the the Eav C•unv r fascia being set. 3. Continue in same manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm2)square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 MIAMMADECOUNTY e t Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 I ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) Nalllhrough ptasticcc ,, High Profile/Single Pan Tile When mulrod) •ti Paddy 16orwAth Til■) w„&O,y,,,,m I Starting at the eave course,apply a minimum 2" (50.8 ,�• r"•,�, ,� mm)x 10"(254 mm)x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. Insure approximately 17(109.7 cm2)— '} 2In. :G,, � `'�_ '� "�., 'r - 23 (148.4 cm2)square inch adhesive contact with the eam"optional ! .._' underside of the tile. •�''`•4 "�. �``w ;w , '' 2. At the second course,apply a minimum 2"(50.8mm) EaveCo �� --Fascia x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the WasphCA. ;mderlayment positioned as shown under the pan loin. in. ✓ €N*&swa portion of the tile closest to the overlock of the tile +-` f di1p° being set. 3. Continue in same manner.jnsgm approximately ITU••• • (109.7 cm2)- 19(122.6 cmly§quAre inc,:•adlla~,sive • . . .. ...... contact with the underside o e.file. .... .... . . .... .... ..... ...... ... . ..... � e . . • • ••.••• i � NOA No.: 17-0322.03 Mla�lEoane couNTv Expiration Date: 05/10/22 e Approval Date:04/27/17 Page 8 of 11 1 • ADHESIVE PLACEMENT DETAIL#3 •' ' Hall through plastic cement Paddylbedreentilea lerhenrequlredi 1. On the eave course only, apply a minimum 2" (50.8 attens optional ° mm)x 10" (254 mm)x V (25.4 mm)foam paddy B o Padidy(under tile) onto the underlayment positioned as shown,under single paddy the strengthening rib for flat tile or under the pan an tapaFtile � : portion of the tile for low or high profile tile closest j `�., to the overlock of the tile being set.Leave x a�simale pad `-. �'`<.;� approximately 4" (10 1.6 mm)up from the eave Sbrglepaddy ,� ""dam°I `-•,, edge free of foam to prevent the expanded adhesive onunderlayment zxain from blocking the weep holes. Insure ��a,'�•,, approximately 17-23 int(109.7-148.4 cm2)of ascla torn �, adhesive contact with the underside of the tile i - -�r�awea°snre 2. Apply a4" (101.6 mm)x4" (101.6 mm)x 1" (25.4 mm)foam paddy onto the underlayment just below Flat/Low Profile Tile the second course line positioned form paddy under the strengtheningrib fpr flat ti:C,•dr ander t1V•.•• Hall through plastic cement Single paddy under tie pan portion of the the' closest to the&wdeslock for .' ren required) Paddy(hetwmtiles) the second course tile tube installed; I;svre ....:. approximately 8-9 int(9P.6:98.1 cm2)of adhesive•• Battens ( paddy(under contact with the undersidbdithe tile:"•'. • • optional ' .... .... ..... . . .. .. .. ...... singlepaddy '-. (Instructions continued on",page) , �• ontopoftile� _ • • • 4x41n. •••.•. Sin epaddyon • • • •....• edayment/— •• • ••• • • • (( �'�. • • tin. •• f —«Eave Closure Save Course Fascia Medium Profile Tile NOA No.: 17-0322.03 MIAMFUADE CO=UNTYExpiration Date: 05/10/22 Approval Date:04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) Hall through plastic Single paddy under tile (whenreguired) 3. Also apply a 2" (50.8 mm)x 4" (101.6 nun)x3/4 paddyihetwe4ntiiesl (19 mm)paddy on top of the eave course tile de's Paddy surface as shown, on top of the strengthening rib OptiDual = for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. �Sk4Mtumn rddy -' Install second course of tile.Insure approximately aa�un ria a;_-- "4x4in. 9(58.1 cm')- 11 (71cm )square inch adhesive contact with the underside of the tile at the overlap Sk4eon 2141 and `�� . and 7(45.2 cmZ)-9(58.1 cmZ)square inch paddy topae—' adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. Ewe l curse � fasda _ Weephok loin. tin. Eavedawre Drip edge High Profile Tile . . ; 0 0 0 60 60 0 6060 . 6060 0 0 0 0 0.0 60 0 60 0 %60 60...60 60 606060606060 :000-: ..6060 60 60 .606060 0 0 0 0000 0000 006060. 60 0606006060 000 0 0.60060 6060 6060 6060 .6060.60. .60.606060 60 60 . • • • 060 0000 :006:6 0 60 000 6060 0 0.00 0 0 0 0 I k NOA No.: 17-0322.03 MIAMMDADE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 10 of 11 4 1 • ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile 1. Starting at the eave course,apply a minimum 2" t)Place enough adhesive to achieve 65 to 70 sq in. Steep pitch applications 8 50 ( . rm11 X mm x . mm in contact with the pan lite. (when required) \ ) 10" 254( ) 1" 254( )foam 2►Turn covers upside down.Place adhesive in paddy onto the underlayment positioned as to t In.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave Then install the tile.Ensure 20 to 25 sq.in.contact area. --:° tiles from rocking until adhesive has a chance to IUnderlayment cure. ° 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2)—70(451.6 cm2) square inch adhesive contact with the underside of the pan tile. Eave closure Sheathing (motor shown) 3. Turn covers upside dawn f xposini the 6derside.•.. weephole Fascia Board of the tile.Apply a mir+ialum 1"(25.4 mm)x 10" .• • (254 mm)bead of adhesile directly ox tfie innan•..• . Remove top portion of the eave course cover tile.Abut to second course of edge of each side of the tMr tile.Leave • pan tiles.Ensure eave end of pan and cover tiles are flush at eave line. •.•. approximately 3/4„(19MrN to 1".(27 4 inm).(l74mm) Two Piece Barrel-High Profile Tile from the outside edge of tile,inwara,free of:0 0. foam to allow for expAnlo r. • 4. Turn cover tile over ager foam is zeplied and o e s e:• place onto pan tile course.4nsure a minimum of • 20(129 cm2)-25 (161:3 cni)square jn1h %***• contact area on each side of the cover Olt to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2”(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized, stainless `steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE t NOA No.: 17-0322.03 MIAMMADE COUNTY Expiration Date: 05/10/22 e t Approval Date: 04/27/17 Page 11 of 11 r` MIAM E • _ MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590'F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA Inc. 1111 W.Newport Center Drive Deerfield Beach,FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).' This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,ft4t.or suspend the use of such product or material within their jurisdiction. RER reserves the right to reavoke this acceptaneJ,":' if it is determined by Miami-Dade County Product Control Section that this product or matjgoih ails to 00 eke •••..• requirements of the applicable building code. ...;.. • . This product is approved as described herein,and has been designed to comply with the FloridaBuildin�Code :"": including the High Velocity Hurricane Zone of the Florida Building Code. •••••• 00000 ••••• ...... •,•• • •••.• DESCRIPTION: Polyglass Polystick Underlayments """ ...... . . . . ...... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo.city. state�ti Mowing • statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein•• ... :" RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8. The submitted documentation was reviewed by Gaspar J Rodriguez. I G raarsioanecourvrr NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/1.6 Page 1 of 8 4 'R901FING COMPONENT APPROVAL Catesory: Roofing Sub-Cateiory: Underlayment Material: SBS ,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65'x 3'3-1/s" ASTM D 1970 A fine granular/sand top surface self-adhering,APP Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous Location#1  60 mils thick sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice&rain shield. Polystick Dual Pro 61'x 3'3-1/s" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location#2 metal roofing and roof tile underlayment. Polystick Tile Pro 61'x 3'3-1/8" TAS 103 and A rubberized asphalt self-adhering,glass4ilhwSpolyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing met'gkmne.Designed as a metal �• roofing and roof tile underlays • 0 • • Location#2 •• •••••• Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhgi:ng*polyes��*reinforesil•00 Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Dhj&g0d as aaQlgf'tile ••••• Location#I  underlayment. 000000 0 Polystick32'10" "TU P 3210 x 3'3 3/sTAS 103 and A rubberized asphalt wate *00000membr e 0 glass- 130 ••..• p rPL44fl�3g arI , g •• Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with I glanular surface 0 0 0 0;0 ...000 Location#2 designed for use as a tile roof underlayment. 0•• Polystick TU Plus 65'x 3'3-1/s" TAS 103 and A rubberized asphalt self-adhering,glass-fibdripolyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal Manufacturing roofing and roof tile underlayment. Location#I  Polystick MTS 65'8" x 33-1/8" TAS 103 A homogeneous,rubberized asphalt waterproofing Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film Location#2 on the upper surface for use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Polystick MTS Plus 65'8"x 33-1/s" , TAS 103 A homogeneous,rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location#2 on the upper surface for use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Elastoflex S6 G 32'10" x 3'3-%" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location#2 use in roof tile underlayment systems. f NOA No.: 15-0410.04 ;MAM caunrrr Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 2 of 8 MANUFACTURING PLANTS: • 1.'Hazelton, PA 2. 'Winter Haven, FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Reaort Date Trinity(ERD P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 &G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103,TAS 110&ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 &TAS 110 :..i 0407/14 P43290.10.14 ASTM D 1970&TAS aj0; 19/17/14***::* PLYG-SC10130.06.16-3 TAS 103 &TAS 110.... '06127/16....;. PLYG-10130.06.16-1 ASTM D1970&TAS,4106/27/16. . 0000 ...... PRI Asphalt Technologies PUSA-035-02-01 TAS 103 .09129/06.,... PUSA-055-02-02 TAS 103 •••••• ... 12410/07..:..' PUSA-089-02-01 TAS 103/ASTM D4798 toe(3155 0906/09•..... Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798 k G115 :--0101/08""" RX 14E8A TAS 103/ASTM D4798 q.01 15 11(09/09;•••• DX23D8B TAS 103/ASTM D4798&G155 02118/10 DX23D8A TAS 103/ASTM D4798&G155 02/18/10 i LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMFDADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 15-0410.04 k[1ISF9F,0ADE COUNTY Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 3 of 8 L 1 INSPALLATION PROCEDURES: De6k Type 1: Wood,non-insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus, self-adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood,non-insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. :•"•• 0 6 0 6 6 Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4'0'Oh dd lap. (fo� • base sheet only) 0000.. .6000. 0000 0000 . . r Membrane: Elastoflex S6 G, of asphalt applied 0 0000 0000 0000:0000 000. Surfacing: See General Limitations Below. •0 0.0• 0:000 0 0 0:0 0• 0 . 60 •• 6• .•66.6 Deck Type 1: Wood,non-insulated 6 0000.. 0066% 0 Deck Description: Min. 19/32" plywood or wood plank 6.0 0 0. System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-1&ered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus,self-adhered with minimum 3"horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus,self-adhered. Surfacing: See General Limitations Below. NOA No.: 15-0410.04 CIEADEC0=UExpiration'Date: 09/13/21 Approval Date: 08/11/16 1 Page 4 of 8 w t°J INSTALLATION REQUIREMENTS: 1. ,, All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. s Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%s" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building ' code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tApasUl be pressed in place and formed around the protrusion to ensure a tight fit. A second la7ioaf Folyst ick shall be ••• :• applied over the underlayment. ...... •. •••••• GENERAL LIMITATIONS: ••••' 1. Fire classification is not part of this acceptance. • ..... 2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Ppy�ti ck MTS Plus may ge 0::• used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof til:systepps aqd quarry••;• slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing..• •'••• :0000: Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile s js ems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. Ex osure Limitations(Days) MTS 1R-Xe Elastoflex TU TU P Tile Pro Dual Pro TU Mai MTS Plus S6 G Plus Winter Haven,FL 180 90 180 180 180 180 180 180 180 Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A NOA No.: 15-0410.04 MAMICADE COUNTY Expiration Date: 09/13/21 Approval'Date: 08/11/16 Page 5 of 8 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and .Rule 61G20-3 of the Florida Administrative Code. S.• In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope shall be as follows: (See Table Below) Tile Profile Polystick MTS Elastoflex Polystick TU Plus,TU P, Polystick Polystick S6 G Tile Pro,Dual Pro TU Max MTS Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 without battens Profiled Tile Prohibited 4:12 6:12 6:12 :,A-0- without without battens • The above slope limitations can be exceeded only by using battens in accordance witV OV'Approved File System• • Notice of Acceptance and applicable Florida Building Code requirements. When battegs.Ore requiged,•they s4fl•••; be utilized during loading and installation of tiles. •....' ..... l 10. Care should be taken during the loading procedure to keep foot traffic to a minimum WN avoid dr-hp,lPing of , tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for lo4jigg procedure•—two tiles •• laid perpendicular to slope followed by a maximum four tile stack parallel to the slooe,fbr:t total•of 6 xiles—We 0:• all underlayments except Polystick MTS which shall be loaded onto battens. :••••• .. . . . ...... rFji' i -------------- NOA No.: 15-0410.04 fiLRMMADE COUNTY Expiration,Date: 09/13/21 — Approval Date: 08/11/16 Page 6 of 8 " f d Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with ' y specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro, Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes toawood deckst•I•nsiallers are.. . cautioned to refer to applicable local building codes prior to direct deck installation toVhsute this;is ampptable. •• Please also refer to applicable Product Data Sheets of the corresponding products. "':" ' " 040000 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as eopPeVglas3" Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum•?b/8" metal•drsk as ••••• required in Miami-Dade County or simplex type nail as otherwise allowable in otherYLgfd*,at a*&tWn:um rate•••• of 12 o.c. Polystick TU Plus should be back nailed in designated area markednail area, area para clava? on the face of membrane,with the above stated nails and/or disks. The head lap membr4ie is tp cover the area be�g&.:• back-nailed. (Please refer to applicable local building codes prior to installation.) .• :00000 0•••• 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact ' 4. All fabric over fabric; and granule over granule end laps, shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. f 6. Battens and/or Counter-battens, as required by the tile manufacturers NOA,must be used on all projects for pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/."/12",precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair,followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. r�oarsE_aanE coon?rr NOA No.: 15-0410.04 AM . Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 7 of 8 10: All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800)894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services f Department at 1 (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE ;• • ...... . .. ...... .... .... . . .... .... ..... ...... ... . ..... .. .. .. ...... i NOA No.: 15-0410.04 EC-- COUP Expiration Date: 09/13/21 ' -` Approval Date: 08/11/16 j Page 8 of 8