Loading...
RF-17-2867 C I V I L Reileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123rd Avenue Miami,Florida 33175-1174 Tel:305-823-8008/305-397-6414 ENGINEER Fax:305-823-3300/305-884-8834 Website:www.reilehengineering.com February 9, 2018 John Busta Roofing 300 Northeast 91 Street Miami Shores, Florida 33138-3130 Project: ROOF TILE UPLIFT TEST REPORT Residential Home 451 Northeast 91 Street Miami Shor lorida Infor anon provided by client: Peri it Number: RF 12172867 Dat Completion: February 7, 8 Roo - g Contra l sta Roofing Project Number: (Testing Laboratory Certificate 411-0715.04) Dear Sirs: In accordance with your request and authorization, a representative of Reileh Engineering (:orporation completed the Roof'1'ile Uplift Test at the above referenced project. 'This testing was performed in general accordance with Rooting Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set the system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground surface. The type of tile used for this project was reported to be Boral barcelona Roof"Tile. ''his tile was reported to have been foamed in place. At the time of our inspection, the entire area of the roof was examined for loose tiles. Not less than one(1)tile in ten(10)of all components in the field area and one(1)the in five (5)of all tiles in the perimeter and comer areas were physically examined. A minimum of one (1)test per every two (2) squares in the field, one (1) test per square in the perimeter area, ridge caps and one (1) test in each corner v ere conducted. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above-mentioned protocol. Attached please find a copy of our test report for your review. } a Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation M amad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT TEST Residential Home 451 Northeast 91 Street Miami Shores,Florida Submittals: Cover Page Page 2 thru 5 of 5 Drawing 18-0159 i , Reileh Engineering Corporation--project Number- 18-0159—Page 2 of 5 I Report of TILE UPLIFT TEST for Residential Home r 451 Northeast 91 Street Miami Shores, Florida Project Number: 18-0159 Test Number Test Load lb Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass a 9 35 Pass 10 35 Pass 11 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass + 17 35 Pass 18 35 Pass 19 35 Pass + 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass Reileh Engineering Corporation--Project Number- 18-0159—Page 3 of 5 Test Number Test Load lb Test Status t 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass 37 35 Pass 38 35 Pass } 39 35 Pass t 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 1 52 35 Pass 53 35 Pass 54 35 Pass Reileh Engineering Corporation--project Number- 18-0159—Page 4 of 5 Test Number Test Load lb Test Status 55 35 Pass • 1 56 35 Pass I 57 35 Pass Test 1-10 Corner, 11-17 Ridge Caps, 18-28 Perimeter, 29-57 Field E 1 1 i i Y f r Reileh Engineering Corporation--Project Number- 18-0159—Page 5 of 5 1 75' ' 1 99 24 25 26 B 7 41 4D 45 42 44 57 54 2459 38 -/4,6 33 3 'M 27 40 55 53 72 57 56 54 , 47 45' 52 1 2 n 21 20 N 50 26. 51 48 19 29 49 50 Z4 6 18 5 NUMMr OF T�5T PPPIMesk - 1000 5F 0 0176f CAP 1E5T LOCATION _ FIPLn - -29 COUP - 50 y 5P - - - Q CEP OMW - 10 P�PIM�T�P P15TANCE,a = 3' IENOTt5 00 ME 18-0159 Q2CAF CAP - 7 COUP APIA- 5'X 3' AMOX,WOO 1E5T LOCAION5,PgA5, ANP t71MFN9ON5