Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-17-2767
i Permit NO. RF-11-17-2767 �sxO1iEs y,� Miami Shores VillageM Permit Type:Roof 10050 N.E.2nd Avenue NEPer ' Work Classification:Metal - Miami Shores,FL 33138-0000 Permit Status:APPROVED Phone: (305)795-2204 toRivA Issue Date: 1218/2017 Expiration: 06/06/2018 Project Address Parcel Number Applicant 10653 NE 6 Avenue 1122310120010 MIAMI COUNTRY DAY SCHOOL Miami Shores, FL 33138- Block: Lot: 1 &2 Owner Information Address Phone Cell MIAMI COUNTRY DAY SCHOOL INC 601 NE 107 ST (305)759-2843 MIAMI FL 33161-7165 Contractor(s) Phone Cell Phone Valuation: =40,821.09PAUL BANGE ROOFING, INC. (954)981-7663Total Sq Fee Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF METAL Inspection Type: Classification:Residential Tin Cap Scanning:4 Final Roof Final Roof Cap Sheet I Roof in Progress Renailing Affidavit Review Planning Review Planning Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-11-17-65716 CCF $24.60 11/21/2017 Check#:5221 $50.00 $860.73 1 DBPR Fee $4.88 DCA Fee $3.25 12/08/2017 Check#:5308 $860.73 $0.00 Education Surcharge $8.20 Bond#:3585 Permit Fee-New Roof $325.00 Scanning Fee $12.00 Technology Fee $32.80 Total: $910.73 4 In consideration of the issuance to me of is ermit agree perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in s cc rmity wi th pla ,drawing , statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this'pera I sume res nsibil fo all ork done y either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRI L,PLUMBI M H L,WIND S,DOORS,ROOFING and SWIMMING POOL work. OWNERS AkIFIDAV : I ce ify t all t regoi g i ation is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ing. F la orize a -named contractor to do the work stated. December 08, 2017 ' Authorize ignature:Owner c / Contractor / Agent Date d' Building Department Copy December 08,2017 1 r r Job Address I b los 3 N G [P 4 v t= Permit#R F--I I -1-1 a 1 (0-7 .Complete the re-nailing affidavit and provide two copies signed and notarized. Post in the permit package at first inspection Re-Nailing Affidavit I am a Florida Professional Engineer, Registered Architect, Licensed General Contractor,. Building Contractor, Residential Contractor, Roofing Contractor or Person certified in the structural discipline under FS468. I hereby certify that the existing or supplemental fasteners have satisfied the requirement of table 201.1 (8d rou ring shank @ 6"o.c. max.) C -Ifier's Signa u Date Print Certifier's Nami I S ubscribed before me this ? day of J�Q( e,{-.,i 20� . 4. Personally know to me or or produced ID Seal -#V►,, Notary Public State of Florida Yvette No ly Public, ort a(signature) My commission FP 974520 'IQ ry Expires 03/2312020 Comp ete Secondary Water Barrier affidavit and provide two copies signed and notarized. Post in the permit package at first inspection Secondary Water Barrier Affidavit I am a Florida Professional Engineer, Registered Architect, Licensed General Contractor, Building Contractor, Residential Contractor, Roofing Contractor or Person certified in the structural discipline under FS468. r I hereby certify that the secondary water barrier has been installed and inspected by me personally it complies with all requirements of FBC 2004 and the Hurricane Mitigation requirements. Certifier's Signature Date Print Certifier's Name ` Sworn to and subscribed before me this day of 20 Personally known to me or or produced ID Seal Notary Public, State of Florida(signature) 1 v t Miami Sly®res Village RE����r�D BuildingDepartment NOV 2 2017 10050 N.E.2nd Avenue Miami Shores Florida 33138 B ' Tel:(305)795-2204 Fax:(305)756-8972 .{- 1 1/ INSPECTION LINE PHONE NUMBER:(305)762-4949 l FBC,20I BUILDING Master Permit NQXkA ` 6a PERMIT APPLICATION Sub Permit No. F-]BUILDING ❑ ELECTRIC XROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [-] MECHANICAL ❑PUBLIC WORKS [:] CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 10053 P t✓ (.D AVC ` City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: )) -Z23 ( -0 12—001 D Is the Building Historically Designated:Yes NO X Occupancy Type:Cvw%n%kv4ad: Construction Type: Rv�(�Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder):rAlt}n'Ii n nl✓'! ;Cj 00 I Phone#:,5 -OL"- n l� i Address: � LoQl 1JC ID-1 5[t-t,Ct City: MIK1Mi State: A Zip: 3311"1 Tenant/Lessee Name: Phone#: Email: '-'�?"G CONTRACTOR:Company Name: C"." 9 L �00� Phone#:q-) qz l-"(L Le Address: City: State: Zip: i Qualifier Name: Ps 1 I �1(ni.�(n Phone#(ta�I--7 1" State Certification or Registration#:C CL S 3 Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: G Value of Work for this Permit:$fig 2 I (3 Square/Linear Footage of Work: 'S Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: P'e-V-(00- — Y-VN e-\-CSL J Specify color of color t# u+" J: Submittal Fee (jDPermit Fee$ 3, CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ pt=� o-7 TOTAL FEE NOW DUE$ `l'y (Revised02/24/2014) - Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) ' Mortgage Lender's Address t s r � City State Zip i Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC_, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS,HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature JZL, Signature/`� OWNER or AGENT CO TOR ! The foregoin strument was acknowledged before me this The foregoing instrument was acknowledged before me this day of A)n(2&Wa(A 20 by day of AklAtA&l .2 by S who is personally Known to who ersonally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign- Sign: P t: o v--, e d Print: 12O rV-1�- Seak Seal: ?#V vy,, Notary Public State of Florida n Yvette Borromeo Notary Public State of Florida My Commission FF 974520 Yvette Borromeo i My Commission FF 974520 o� Expires 03123!2020 r X 3 701, ( r APPROVED BY Plans Examiner Zoning Structural Review i Clerk (Revised 02/24/2014) { - • w__. , OFFICE OF THEPROPERTY APPRAISER Summary Report Generated On:9/28/2017 Property Information Folio: 11-2231-012-0010 10653 NE 6 AVE Property Address: Miami Shores, FL 33138-2051 Owner MIAMI COUNTRY DAY SCHOOL INC p 601 NE 107 ST Mailing Address MIAMI,FL 33161-7165 PA Primary Zone 1100 SGL FAMILY-2301-2500 SQ e 1 7241 EDUCATIONAL/SCIENTIFIC- r Primary Land Use EX:EDUCATIONAL-PRIVATE Beds I Baths/Half 0/0/0 Floors 1 .. Living Units 0 Actual Area 8,864 Sq.Ft , Living Area 8,864 Sq.Ft "s Adjdsted Area 7,746 Sq.Ft Lot Size 28,581 Sq.Ft Taxable Value Information Year Built 1940 2017 2016 2015 County Assessment Information Exemption Valu1,274,9731 $1,159,067 $1,053,698 Year' 2017 2016 2015 Taxable Value $0 $0 $0 Land Value $886,817 $834,601 $667,681 School Board Building Value $611,195 $589,292 $536,844 Exemption Value 1 $1,553,463 $1,479,939 $1,255,332 XF Value $55,451 $56,046 $50,807 Taxable Value $0 $0 $0 Market Value 1 $1,553,463 $1,479,939 $1,255,332 City Assessed Value 1 $1,274,973 $1,159,067 $1,053,698 Exemption Value $1,274,973 $1,159;067 $1,053,698 Taxable Value $0 $0 $0 Benefits Information Regional Benefit Type 2017 2016 2015 Exemption Value $1,274,973 $1,159,067 $1,053,698 Non-Homestead Assessment $278,490 $320,872 $201,634 Taxable Value $0 � $0 $0 Cap Reduction Educational Exemption $1,274,973 $1,159,067 $1,053,698 Sales Information Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Previous Sale Price OR Book-Page Qualification Description Board,City,Regional). 01/01/1991 $81,800 14944-2137 1 Other disqualified Short Legal Description GOLF VIEW EST CORR PL PB 41-58 LOTS 1 &2 LOT SIZE 190.540 X 150 OR.14944-2127-25 0191 6 t The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp. i Version: i r 1 2017 FLORIDA NOT FOR PROFIT CORPORATION ANNUAL REPORT FILED DOCUMENT#744085 . Jan 10, 2017 Entity Name"MIAMi,COUNTRY DAY'SC_HOOL,,INC.7 Secretary of State CC9899669453 1Current Principal Place of Business: 601 N.E. 107TH STREET MIAMI, FL 33161 Current Mailing Address: 601 N.E. 107TH STREET MIAMI, FL 33161 FEI Number: 59-1278987 Certificate of Status Desired: Yes ,Name and Address of Current Registered Agent: DAVIES;JOHN V 601 N.E.7107TH ST MIAMI,FL 33161 US The above named entity submits this statement for the purpose of changing its registered office or registered agent,or both,in the State of Florida. .SIGNATURE: Electronic Signature of Registered Agent Date Officer/Director Detail Title DP Title DS Name CHRISTOPHER,BELLOWS Name LAZENBY,MATTHEW Address 134 NE 102 STREET Address 420 LINCOLN ROAD City-State-Zip: MIAMI SHORES FL 33138 • SUITE 320 City-State-Zip: MIAMI BEACH FL 33139 Title DT Title COO Name FARREY,JOHN F Name BUTTS,GARY T Address 1315 BAY TERR Address 601 NE 107 ST City-State-Zip: N BAY VILLAGE FL 33141 City-State-Zip: MIAMI FL 33161 Title 1 VP Title 2VP Name PREMER,HOWARD Name MOORE,JAMES Address 2010 NE 120 ROAD Address 5905 NORTH BAY ROAD t City-State-Zip: NORTH MIAMI FL 33181 City-State-Zip: MIAMI BEACH FL 33140 I hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath;that I am an officer or director of the corporation or the receiver or trustee empowered to execute this report as required by Chapter 617,Florida Statutes;and that my name appears above,or on an attachment with all other like empowered. SIGNATURE:GARY T. BUTTS COO 01/10/2017 Electronic Signature of Signing Officer/Director Detail Date M R93 Liami hOres Village PII 11111M Building Department 10050 N.E.2nd Avenue ORTDp; Miami Shores, Florida 33138 Tel: (305) 795.22C-4 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- t BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 / n Re: Owner's Name: t Jo- 1 Property Address: 100-1-3 &45 1/cr, Roofing Permit Number: DearBuilding Official: , I_, ®hn Ame 5 certify that I am not required to retrofit the roof to wall connections of my building because: [3The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the'provisions of 1994 edition the South Florida Building Code(1994 SFBC) C) igna re Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes anjsays that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this /b day of N(y a 7 o °I Notary Public State of Florida Notary Public, Sate of Florida at Larg f Yvette yt neo My Commission FF 974520 ora Expires 03/23/2020 • When the just valuation of the structure for ose of ad valorem taxa n is equal to or more than$300,000.00,and the uil in was not construc e with B nor a 99 SFBC.Then you must provide a building application from era Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 512112009 Miami COUNTRY DAY SCHOOL September 20, 2017 Miami Dade County Re: John P. Davies, Authorized Signer To Whom It May Concern: This is to confirm that John P. Davies, Head of School of Miami Country Day School is an authorized signer on behalf of the organization. Sincerely, Com` Christopher Bellows, President >, i�' �r !.4' Board of Trustees Miami Country Day School, Inc. � bso 6a 1A rc�, -X-1,0NV) IJ\ ���NNttttttltH�����. ✓L ���� �p31V1S �T ....... �•��?Hyl DoA�p°•,j,•yQ6�i"' . � � '��'° x� ' a °•;`'o L 4r —ter=- ��,1 Z ••• :4_ /n/oMIIIIt1111N�\\`\\``� 601 Northeast 107 street I Miami, Florida 33161 1 305-779-7200 1 www.miamicountryday.org Every Student.Every Day. John Kenney 954-553-8929 7000 SW 215'PLACE . �p -STATE CERT:CC C033691 DAVIE, FL 33317 ���" DQQi LICENSED AND INSURED W BROW:(954)588-ROOF'(7663) • "Si BROW:(954)981-ROOF(7663) R � ger Fax: (954)964-ROOF(7663) nite .Care Club Proposal PROPOSAL SUBMITTED TO n 09-19-17 PHONE: Contact:Mike Caban 305-206-1761 Contact:Li Cuevas 786-3514965 NAME Mike Caban 108N111E Miami Country Day School - Sommers Hall STREET 10653 N.E. 6th Avenue CITY Miami.Shores STATE Florida PIP 33138 We hereby submit specification and'estimate for PREP.WORK METAL $40,821.00 ;q Rerrriove existing roof to a clean workable surface [A Install Versa Shield fire barrier'as per code. and dispose of debris. Pq Install 301b. premium underlayment. N Replace rotten sheathing at$4.00 per linear foot [XJ Install matching bullnose eave drip metal: (plywood by sq.ft.) [)j Install Standing Seam 16" panel 24ga. metal roof. [A Install dew lead flashing to all plumbing vent stacks. N Install new 26 gauge 16"galvanized metal to all valleys and tie-ins. [':) Exposed N Not Exposed M Type of roof to be removed. Tile Gutters, Canvas Awnings, Stucco work are not with in the scope of this proposal. Price'Includes: Permit, Taxes, Engineering, Dump fees, Rodent Screens on stacks. Option: Enhance Roof to Wall connections Add $5,066.00. ,Wfhereby propose to furnish labor and materials corrrg�plete in acc rrd nce with the a� cifications fo a sum ofo U 4U SO+(1C� C—i 1/1��l�1n(yC �1J� �(1 a �ollars c, )$�( . Q Method of Payment: Cash;Check, to be made as follows: No Deposit:60% at start, 3 % metal load, 10% Day of Credit Card(No Amex.)A`2.5%service charge will apply to all credit-card payments. I completion. WARRANTY TO ORIGINAL OWNER Paul Barige Roofing Inc.warrants workmanship for period of five'years. { CUSTOMER IS URGED TO COVER FURNITURE AND OTHERWISE PROTECT THEIR PROPERTY. THIS CONTRACT IS SUBJECT TO OFFICE APPROVAL Authorized:Signature 40 Representative Na-me John Kenney _t ACCEPTANCE OF PROPOSAL The above prices,specifications and nditioas amsatisfactory and are hereby accepted:You aie auttiorized to do the work as specified.Paym " will be made-'as .outhhed'above.This proposal powrr of 'hen signed and`accepted.I have read and agree to the terms and conditions as ated above. Signature ACCEPTED 1 0 I PRINT NAME' a D61:6 i SHORES VILLA CONDOMINIUM 8901 NE 4TH AVE RD MIAMI SHORES, FL 33138 November 14,2017 To whom it may be concerned: C Please be advised that the Shores Villa Condominium Board of Directors has authorized and approved ' Paul Bange's Roofing to utilize and install Desert Tan roofmg shingles for installation at the Shores Villa Condominium. Thank you Wade Patterson President Shores Villa Condominium Association I " I I n , e ff ._. Mem M o. A6 i6 . �..�., 3 X a ' f • f " f • � r ■ i r •• ♦ • ,• • t t • • • / � ��■ If•`r+r *r'ry r 1.41.1 In M15521MANOR 1 qq■gN4111m algq q ■��''1■iii�::a■■i •■tq ■ ■q I�■ ■ l-�� rt—r r.�... ��_'�-----e�_� r. r a ■ Iq ■ ■ ■ ■►Ir x.y�ric,y�.r'�L"■�•Lr�l�'rlY;f�■� �')I r��;q q . aiq q ISA all ■ C r ■ C l.\ 1f+1■ti+I[sr rr J I ■■ ■ /.C' ]] r ■Irr■r■{ G �G Gf�CG■ri!•'�G ?Ell .� �r..q q ....-�- q r� ,..:�. i qqq■ q .. r ■ ►'U■ ■ a`�■■g$■■ ■■■.■ ■ N fit T I . Ir A . r■ GggG■■il�'.gr.■ .q Cr�� �E�SrliI q ■�1i, �■qq � EG 1`{ q Cq E'r.q ri■q . .i ■ ■ 71 1qe q IBlul I !I111mul1r ► Ali'■I ■■ qqicing . A it q� q� ■ i■�y �. �• ' q:eid''L rL'CI �..sss s.. r r.■ . a r. ■ . 1 q ■"G q` ii q'qG 1: 1 a 'C " CC'q Ilion ' qi Iqr {q r ■ ' G aid* r.a 1� rq ► C �■q■ . . ■ q ■.I '. ■ qq. L. n �" -r• ,� q rr w In �wr��•� � � rGr���R t7� gs��G��r�iGn�r_�Q�--`• ►�■q i X11■ q r�l�r l r -d SHIM-11111111111�i"1 Pull 11 5■E■ rl mai �� q ■�{ C r•s I 9E ■ ■ ■■■ �C q . qfI i� . q q ,• ■ s2G ■ q■ q h� qmum I ; ■Iq■ I 1q�!g10am ■ ► :-c @l■� . .■ is qq qgq�q ��■... � 1 , it ■r s .e r ■■rrr.a rr .r�r 2"— r►1r �j■ qq i 14 10-04111 � �rqi q qq �I 'Big! q •■i■ qq q. a �■ .aE� ■ .;1 rr q q c qr qq.■ q 14..■ , Cq q l ,t ' ■ E ■ .■ ■ I■ . � s$.`-.'.....«��n.•rr r n■_`■_ rr �■��q � �� � I111�CI1C �q� i1 f �EI� ■ M r Nq q q ■ 1l i sa mill q q r �.•et �eM i�R �1A ■ ■ gq'gq q ■ ■ q I i L� HI��L•mill I I ■ • Am Am q!1jif1j!L a r ■ r q it fittI . r� HIM ■ {� ■R11,1,11111ul r�Isr Mrfr ■rq q� q�: v;rr.► ' 'qqq ■ r■ ■loll� Fi q�I`LI�q"ii q■ . ■ r■ 1'r ■ q qqq ! �"`E �� in q. q . . qp q C q ,roll, �q C .I CC ■ qq ■ ■ I l .1. ■ q • ,r■l E J q rq- -e�•q ggrq C._ �I . I • q �!■■ _ '�� �I�• C ■ rt -s^-.� -;tet= r :w,ti1 2 f I :!Sr..Qqq - - Rit q M •i l k IBJ :�1(./ :��l�El�r �L �i�t F i1 '•■ r.q�q.. ■q � 11 giEftllR�•>:l� gq�gq■�i1 ra.P94 'max 10 - -- ■srvt••�.oxw+••�rrrw Florida Building Code 5th Edition (2014) High-Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof-System Manufacturer: Notice'afAcceptance Number:��f- `-�Z • Minimum Design Wind Pressures,'if Applicable(From RAS 927 or CalculStjop): P9: P2: P3: ••0000 ... .-. •....• . Maximum Design Pressure 0 From the NOA Specific S stem 1 ( � *00000 Method of4lie attachment. i ox l a>7ac,.Ve ke l"I . . . . ...... . . .. . ... . . . Steep Sloped RoofSvst, em Description E Deck Type: E pe Underlayment: Roof Slope: s nsulatlon: _ -: 12 Fire Harr ,er: Vevsc, Ridge Ventilation? astener Type&Spacing: v� ►� dhestve Type -10- G 5. ype Cap Sheet: ,-� -of Covering: p Mean Roof Height! Type&Size Drip Edge: d • E I 1 4 i MIMIAMI- E "Delivering Excellence Every Day" ------ MIAMI-DADE COUNTY ------ REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is'the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1. Aesthetics-workmanship: The workmanship provisions of Chapter 15. (High Velocity Hurricane Zone) re for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect•to viorknivikv provjSl4ja4• Aesthetic issues such as color or architectural appearance, that are not part of a zoning eoc e, shlVilile addressed 0 asp 000 .. 00000. of the agreement between the owner and the contractor. • 0000.. 0 �1 0000.. 2. Renailing wood decks: When replacing roofing, the existing wood roof-MR-nay;Wto be • • 0000 0 •. 0000. renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurf o na Zoned of the Rctida Building Code. (The roof deck is usually concealed"prior to removing the existing rdbf�ystemT. 0000.. 0..0 0 3. Common roofs: Common roofs are those which have no visible delineation betwedaiJighboiiV9 units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the rohw Lontractor znd/ot owner should notify the occupants of adjacent units of roofing work to be performed. ••• c 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond.(accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distiess and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of- Chapter 15 and 16 herein and the Florida Building Code, Plumbing.' 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be. reduced. Owner's/Agent's Signature: Date: Contractor's Signature:r.. - "r ' `- Permit Number: Property Address: _ v MlltMl•[�Y4�3E ® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 www:miamidude.�ov/economy NOTICE OF ACCEPTANCE (NOA) z Sunlast Metals,Inc. ••• • 2120 SW Poma Dr. •••••• ;•••" ....:. Palm City,FL.34990 •••;•• a SCOPE: •••• •• • .... . .. ..... This NOA is being issued under the applicable rules and regulations governing the use of colyAwipotion mat jr�jt.The ••••' ` documentation submitted has been reviewed and accepted by Miami-Dade County RER-Pr(A!i tControl•Section to ee*•:• used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict6fl:%*[1J). 0 •• This NOA shall not be valid after the expiration date stated below. The Miami-Dade County rro4?4 Control Section :....: (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the Tfghtto have this ,rodu 0 • or material tested for quality assurance purposes.If this product or material fails to'perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is , determined by Miami-Dade County Product Control-Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Jax Beach Series 1.5" Clipless Snaplock x 24ga. Steel Panel over Wood Deck r LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL'of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. f , TERMINATION of this NOA will occur after the expiration date or'if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and k. shall be available for inspection at the job site at the request of the Building Official. This NOA and consists of pages 1 through 6. I The submitted documentation was reviewed by Alex Tigera. NOA No.: 15-0421.03 MIAMI•DADECouNTY Expiration Date: 09/10/20 Approval Date: 09/10/15 Page 1 of 6 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub-Category: Non-Structural Metal Roofing Material: Steel , Deck Type: Wood Maximum Design Pressure -161 psf. • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLIC'A'IMT'.• • ::0009: Product Dimensions Test ➢ educt • Specifications Jax Beach Series 1.5" Length: various TAS 110 Corrosion resistarLtgexformed standing •••. • Clipless Snaplock x Height: 1.5" seam coated pje-fini:hed steel panels. •••••• 24ga. Steel Panel Width: 15-19" • Thickness: 24ga: '.. : '••• • •*so:••' Min.Yield Strength: 51 ksi. •• TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Dimensions Specifications Description Manufacturer Bostik 70-050A N/A various Silyl Modified Polymer Bostik,Inc. Adhesive EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Architectural Testing D4563.01-450-18 TAS 100 07/15/14 C6413.02-450-18 TAS 125 08/19/14 PRI Construction Materials ASTM B 117 04/11/08 Technologies ASTM G152 05/12/08 A P l J NOA No.: 15-0421.03 htIAMI•oane couNnr Expiration Date:09/10/20 Approval Date: 09/10/15 Page 2 of 6 f I APPROVED ASSEMBLIES: System: Jax Beach Series 1.5" Clipless Snaplock x 24ga Steel Panel 15"or 19"wide panel Deck Type: Wood,Non-Insulated Deck Description: New Construction 19/32"or greater plywood or wood plank, or for re-roofing t6g2•''or greater plywood. • Slope Range: 2": 12" or greater •••••• """ Maximum Uplift See Table A below •• .. :"" Pressure: ' Deck Attachment: In accordance with applicable Building Code,but in no case shalt it4be less thr 8tlMng ...... shank nails spaced 6"o.c. In reroofing, where the deck is less th"":;','thick(Minimum • 15/32")The above attachment method must be in addition to existing attachment. o •••••• Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installeditl;a minjm.4" side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistanf din-caps and 11/4'annular ring-shank nails, spaced 6" o.c. at all laps and two staggered rows 12"o.c. in the field of the roll. Or,any Miami-Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in Sunlast Metals Inc.'s . Roofing Installation Manual. Metal Panels and Install the "Jax Beach Series 1.5"Clipless Snaplock x 24ga Steel Panel 15"or 19"wide Accessories: panel" including flashing penetrations,valleys, end laps and accessories in compliance Sunlast Metals Inc.'s current,published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Panels shall be installed along the clipless seam with corrosion resistant#10 pancake head screws of sufficient length to penetrate through the sheathing a minimum of 3/16" at a distance listed below in Table A.A continuous bead of Bostik 70-05A adhesive shall be applied on each side of the male rib before snapping the female end of the adjacent panel in place. See Details herein. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures —97.25 psf —161 psf { Maximum Fastener Spacing 6" o.c. 3" o.c. 1. Extrapolation shall not be allowed F l NOA No.: 15-0421.03 MAMI•DADE.....cou►vn Expiration Date: 09/10/20 Approval,Date: 09/10/15 Page 3 of 6 SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. fielo.ggi:vieters, 0000.. and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening I enhanced • pressure zones (i.e.perimeters,extended comers and corners). 0.00 • :...:. • 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths sh$U be as desoribed in ; Roofing Application Standard RAS 133. •• • • 0 0000. 4. All panels shall be permanently labeled with'the manufacturer's name and/or logo, citv0000 �tate, and the fpllowi%:..' statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade CoAty Pttltitt Control...•• . Seal as seen below. :90:6:. 0 • 0000.. 00.00. , MIAMI•DADE COUNTY 0 :0090 0 .. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 6 P d t 7 NOA No.: 15-0421.03 MIAMI-DAD,COUNTY Expiration Date: 09/10/20 Approval,Date: 09/10/15 Page 4 of 6 t { PROFILE DRAWING T 15"-19" 6666.. • 6666.. . • 6666.. • 1'21 1 .60000 ti f 00.6 1n. 66.66• • 0• •• • • 6.666 . .. 666.6 { _ 00.00. . 666,6.. 00 00 0 6666.. 0 666... • • • 6666.. 6666.. • " 6666.. . . 00 SEALANT f -SEALANT SEALANT- - j" SEALANT 'y f — u — - -- - - - -- ---- ---- - -- --- - - -- - - -- _WOOD - - - -_--WOOD DECK t t 1 r i t NOA No.: 15-0421.03 MIAMI•DADECOUNnr Expiration Date: 09/10/20 Approval Date: 09/10/15 Page 5 of 6 I ,;SUNLAST t5""GLIPLE88'SNARLDC I (4I NEAGH) • • ADHESIVE 4N 90TH .....0 SIDES OF SEAM r.�fix' . �r�';� C7P'TIQNAL '....' ..�..• SIL STIFFEN ING•I��9 ee 00 :...:. ...... �,�`f � '•'`mak .'. ' :....: • - � ref Y FASTENERS EVERY 6" IN FIELD ZONE `` ' FASTENERS EVERY Y PERIMETER AND CbR- NER'ZONES G END OF THIS ACCEPTANCE . I I i NOA No.: 15-0421.03 MIAMbDADB COUNTY Expiration Date: 09/10/20 Approval Date: 09/10/15 Page 6 of 6 1 1 t •••• • •• ••••• • •••• • ••••• } k 15"-19" a i t �• Y b O'ti 4 J unlas tMetal 0 E n .__S7 t ! { " L j, z "'1 ! ` as !t� f Q'k Q1 ,_ k t 1 k 2120 SW Poma Drive; Palm City, Florida 34990 0 772-223-4055 Phone 0 772-781-7492 Fax www.sunlastmetal.com 0 sales@suiilastmetal.com { IMPORTANT NOTICE Page READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF THE 1.50 Inch Clipless (Jax Beach Series) PANEL SYSTEM. SUNLAST METAL DETAILS MUST BE FOLLOWED TO INSURE APPROPRIATE WARRANTIES REMAIN Ipl AFFECT. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE '. INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALI-( IN 6U.ESTION*** NOTIFY SUNLAST METAL IMMEDIATELY IF ANY PRODUCT IS BEL-WVED TO'BJE Ogre OF SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPPING. "" ' " ":" .....• f IF THERE IS A CONFLICT BETWEEN OUR ENGINEER'S EVALUA;T" REPORT AND •; THE DETAILS IN THIS MANUAL, THE ENGINEER'S EVALUATION REPORT WLLLTAKE"' PRECEDENCE. 0 , i Installations contained herein were in effect at the time of this installation manual creation and approved for publishing.Sunlast Metal reserves the right to discontinue products or change specifications at anytime without notice. To ensure that you have the latest material available please contact Sunlast Metal directly. Installation Details are for illustration purposes only can may not be suitable for all building designs or conditions.All projects should be engineered to conform to applicable building codes and regulations. For complete performance specifications and any disclaimers, please consult your local Sunlast Metal representative. i t unlas t Meta Page 3 OFFICE: (772)223-4055, TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 "PRODUCT IN1 1 I Inch Clipless TABLE OF CONTENTS 0000.. 0000 A. Technical Information Sheet ............................................... Pagi.g.;• • B. General Panel Description . ..............................................90%00Pag2 5 0000 10 C. Handling & Storage Specifications ...................................... Page 6% D. Installation Requirements ............................::................'.....•PagE 7..• 0000 E. Fastener Patterns ....................................................... :�e��Page 8 . 0009 . 0000. F. General Installation Instructions . ................................... Page 9 0.00 G. General Installation Sequences .......................................... "V P-age 12. 0 H. Flashing/Trim Metal Details ..............................................,..... Pago•14•• I. Installation Details :•• 0 0 1.., Eave Drip (EDBN-SS) .................................................... . Page 166• 2. Box Gutter (BG1-SS) .................................................... Page 17 3. Gable Rake (GR1-SS) ..>................................................. Page 18 4. Peak Flashing (PF-SS) ...........:........................................ Page 19 5. Peak Flashing 2 (PF2-SS) ............................................ Page 20 6. Gambrel Flashing (GF1-SS) ........................................... Page 21 7. Transition Flashing (TF1-SS) ........................................... Page 22 8. Ridge / Hip Cap - (RHC-SS) ........................................... Page 23 9. Valley (V1-SS) .............................................................. Page 24 1 10.Side Wall Flashing (SW1-SS) .........................:.................. .Page 25 11.Side Wall Flashing 2 (SW2-SS) .......................................... Page 26 12.End Wall Flashing (EW1-SS) ............................................ 'Page 27 13.End Wall Flashing 2 (EW2-SS) ..........:................................ Page 28 t t g f a i ' F unlast Meta/ Page 4 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 ! PRODUCT 1 1 TECHNICAL INFORMATION SHEET 0000.. soeo 0 so 1. Minimum Recommended Slope is 2:12. For slopes less than 3:12, please referetaElArida BGm-'•• 0000 . ing Code (FBC) section 1507.4.2 and/or FBC section 1515.2. G 0 G r 0 e osoo . 0000 .. 2. Support Type: Wood Deck- 15/32" (min)or greater Plywood, or ••...• •..• 0000 Wood Plank (0.42 min specific gravity) 0000.. . . 0000 0000.. 3. 1.5-Inch Nail Strip Panels are a Concealed-Fastener, Standing Seam Metal Rooii'ecels with ' interlocking rib seams and fastening flanges for ease of installation. They.mus;be'netalled over• •••• • Goose. a completely waterproofed structure in order to ensure watertightness. If the w;terprgof mern- :e•e brane is mechanically attached with metal fasteners of any type, fasteners should'be•coveredtq „ protect the under-side of the metal roof panels, or the use of non-corrosive, plastic tags can be •• used if applicable manufacturer of the fasteners and FBC permits it. Any mechanically attach- ment device that does not lay flat on the deck will telegraph through the panels and appear as oil canning. 4. Underlayment specifications will be determined at time of estimate, but all underlayment will be in compliance with FBC Section 1507.4.5. r 5. Insulation is optional, but must comply with FBC Section 1508. When insulation is incorpo- rated, fastener length shall conform to penetrate throdgh bottom of support a minimum of 3/16". General Insulation Details: Type: Rigid Insulation Board Thickness: 3° (Max.) Density: 2.25 pcf(lbs/ft3) min., or Compressive Strength: 20 psi (Min.) 6. Panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the panel at or near the point of.attachment. Oil canning is not a cause for rejection of the panels. f 7. For the proper fastener application, please see the Fastener Pattern section of this installation manual. Fastener spacing across the width of the panel are shown on Page 8. For fastener spac- ing along the length of the panel, use the wind upload table on the bottom of Page 8 in conjunc- tion with the local governing code. 8. For continuous panels over 30 feet, please contact Sunlast Metal for direction. I SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE §unlastMetalPage 5 OFFICE: .(772)223-4055 TOLL FREE: (877)8-METAL,-6 FACSIMILE: (772)781-7492 PRODUCT IN 11 1 1 I Inch Clipless Pax Beach a . f GENERAL. PANEL DESCRIPTION •••••• 15"_fig" 0000•• • 000.0 066:40 • • •0000 0000 •'• • • •.•• 0 •• 004.0 0000•• • • •„•, • +0 0000•• •• ••^ • 0000• • • • • • 0000• 0000•• • • • + 0000• PANEL NAME: 1.50" Clipless Snap Lock (Jax Beach Series) PANEL MATERIAL: Steel PANEL THICKNESS: 24 Gauge (Min.) PANEL WIDTH: 15" to 19" Coverage PANEL RIB HEIGHT: 1:50" YIELD STRENGTH: 40 ksi min. CORROSION RESISTANCE: In compliance with'FBC Section 1507.4.3 ASTM A792 Coated, or ASTM A653 - G90 Galvanized Steel COATINGS / FINISHES: Galvalume Plusew/Additional Acrylume® (Mill Finish) Kynar 500 For OPTIONAL STIFFENING RIBS: Striations, Ribbon Beads, Pencil Beads (Flat - Standard) 6 I { SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE §unlast Metal Page 6 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT 1 / I Beach HANDLING & STORAGE SPECIFICATIONS 0000.. The information provided are suggested guidelines and not intended to cover all applications dr bWllding retluirements."•' • It is the responsibility of the designer/installer to ensure that this.information meets particular butlCin�fcondCipVg,%nd/or ' code requirements. It is also the responsibility of the installer to ensure that all OSHA and/or'df*T%afety'regulations"" are understood and upheld. Sunlast Metal will not be held liable for any claim which arise out df'Itdl?dling or inAallation:... of the material. see* ' •••• • 00 0000 00.00. 00. 0 0000 00.. . 0000 . PERSONAL HANDLING PANEL INSP.'.r.;TION• • ...... When handling metal panels care should be taken to All material should be inspected•upon delivery: Any ••• protect the panels from scratching or abrasion. Pulling damage or moisture intrusion should be repos#i,to a* • panels across one another may cause scratches to the Sunlast office representative within 48 hours and surface film. Individual panels should be carried vertical notated on the Delivery Ticket. to the ground to avoid bending the material. k MECHANICAL HANDLING FIELD CUTTING 4 A forklift or crane can .be used to handle unopened Some field cutting and fitting of pre-manufactured bundles, but care must be taken to ensure equal panels is to be expected. Minor field corrections is distribution of weight across the entire panel. Spread considered normal operation. Always cut one panel at the forklift forks to their maximum width in order to a time. For small cuts, hand-held shears (tin-snips) can ensure equal weight distribution. Use of a spreader bar, be used. For best results an electric shear may prove when using a crane, will enable equal distribution of useful. After cutting metal panels, ensure that all metal weight. Cable supports should be avoided at all costs. shavings are removed from the panel before installation to avoid rust stains, which will void the warranty. PROTECTING & STORING FASTENING DETAILS Material should be left in a secure location to avoid the The use of proper fasteners and installation procedures possibility of theft.-To protect the metal .panels-from is an important factor in the overall appearance and Weather conditions it should be tarped (non-plastic performance of the metal roofing system. When using material) and stored at least 4" above ground with one metal fasteners with weather seal washers (WSW), be end elevated slightly higher to allow moisture to run off. sure that you do not over tighten - causing the sealing If metal panels become wet, they should be individually material to extrude beyond the edge of the washer. 'removed from the bundled stack and dried. Prolong Also, not tightening the fastener enough will not allow storage is not recommended. If immediate installation the proper compression of the washer to seal the is not possible, additional care should be taken to penetration. ensure that rust or watermarks do not develop. Do not , store sheet metal roofing materials in contact with other materials that might cause staining, denting or other surface damage. Store sheet metal materials away from uncured concrete or masonry. r i SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE i C unlastMetal Page 7 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT IN 11 1 / I Inch Clipless (Jax Beach Series) •060.0 INSTALLATION REQUIREMENTS,,•'; 0000.. .00.0. . 0000 . •00000 �. . . 0000 . 0000 .. • 0 • SEALANT -\ 0 0 0 0 . .. •6•• 0o 0 • 0 •00.•. SEALANT L-00 • 6• 6 .•.• . •.6•• .• • . 0000 • Y •000.0 . • • 660• • 600• • �— WOOD DECK Wood Deck(15/32") SEALANT t Integral Snap Lock SEALANT Clip Relief Seam Adhesive a #10 x 1"Pancake-Head Wood Screw 1 G METAL PANELS: 24 Gauge (Steel) INSTALLATION METHOD: Refer to drawings on Page 8 FASTENER SPACING-- Refer to Table"A"on Page 8 FASTENER TYPE: Pancake-Head Wood Screw j FASTENER SIZE: #10 x 1" FASTENER CORROSION RESISTANCE: Per FBC Section 1506.6 and,1507.4.4 1 FASTENER STANDARD: Per ANSI /ASME 618.6.4 MINIMUM FASTENER PENETRATION: Through bottom of support-minimum 3/16". PANEL RIB INTERLOCK: Snaplock(Panel Ribs shall be fully engaged to form and integral snap-lock) SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE + §unlast Meta' Page 8 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 •FACSIMILE: (772)781-7492 "PRODUCT INI 1 FASTENER PATTERNS •••'• �•• •• • . • .**:o* so 00 ...... • BEACH SERIES 1.5 OPTIONAL STIFIINNU RIiiS •' • •• •• ADHESIVE ON BOTH —r ••; SIDES OF SEAM ? I 1 I FASTENERS EVERY ' V IN FIELD ZONE s t: _ FASTENERS EVERY 3" IN CORNER ZONE a TABLE A MAXIMUM(DESIGN PRESSURES Ra©f Areas Field Periirieters end Corners Mamnumi'Desig>ru i�essure' s 97?5 psf -161 osf ScrewSpacing Applied continuously an Applied continuously on Seam Adhesiveboth sides-cm male leg.. both sides on.'male leg. *Maximum Design-Pressures include 2:1 Safety F&Ibbr SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE §unlast Meta/ Page 9 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless (Jax Beach Series) !! GENERAL INSTALLATION INSTRUCTIONS , The information provided are suggested guidelines and not intended to cover all applications qr� gilding requirpments. V is the responsibility of the designer/installer to.ensure that this information meets particular bpjI&g conojji v and/(:t*** code requirements. It is also the responsibility of the installer to ensure that all OSHA and/or oth";WulatiopsVe' .... understood and upheld. Sunlast Metal will not be held liable for any claim which arise out of hago4ggpr installatipn of tha.% • material. ' ' :•0"' •••• • GENERAL PANEL INSTALLATION ..• ' "" ' ... . There are three main measurements that are critical when installing metal roof panels: the length required at the eave, the peak end and the amount of panel lap (if required). In each case a certain measurement is required: Check each measurement to ensure panel placement gives you the distance required at the eave and peak. In most cases, any variance can be taken out at the eave or peak. Insure that the structure is square and true before beginning panel I nstallation. If the structure is not square, the panels will not properly seal at the side-laps. Start the first panel square to the eave by using the 3, 4, 5 Triangle Method (See Below). Green or damp lumber is not recommended. Moisture released from the damp lumber may damage the metal panels. Nails installed on green or damp lumber may back out. Drive fastener so that it is secure against the metal but does not bind: Overdriven fasteners will also increase the amount of oil canning that is present in the metal roof panels. Do not leave any fasteners that missed the substrate. Remove any loose shavings left on the roof immediately to prevent corrosion or rust. After installing the roof system, remove any de- bris such as leaves or dirt to prevent moisture from getting trapped on the panels. TRIANGLE METHOD 1. Establish a line from Point A to Point B by temporarily marking each point with a nail. The line must be parallel to the eave. In this example, we are going to determine that this line is going to be 3 feet in length (This is the"3" side of the Triangle). NOTE: For larger 3, 4, 5 Triangles-multiply each side of the triangle by the desired increase in size. For example, if the roof panels are 25 feet from the Eave to Ridge, multiply each side by a factor of 6 for an 18, 24, 30 Triangle. Obviously the shorter the vertical length of the triangle is, the better accuracy you will have when squar- ing off. 2. Using two tape measures, locate Point C by hooking one tape measure to the nail at Point A and a second tape measure at Point B. Extend the tape measures until they cross and meet at 4ft on the.Point A tape measure and 5ft on the Point B tape measure. Then place another temporary nail at this juncture. ,3. Hook a chalk line onto Point A and pull it in line'with Point C and then mark you chalk line on the roof deck. This will be your square reference line for the panel installation. ,4. Mark chalk lines parallel with the square reference line out ahead of the panel installation so that panel square can be checked as the panels are installed. Suggested line spacing is one foot beyond 3 panels wide or about 7 feet. 5. Check for square by measuring the distance from the installed panel edge to the chalk line at both the eave and ridge ends. If the measurements match, then the installed panels are square, if not, adjustments must be made to bring the panels back to square. NOTE: Please take care when attempting to adjust for square. If completed improp- erly then oil canning will become present. +6. See the following pages for a step-by-step process. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE h q5unlast. Metal. Page 10 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT 1 / ► 1 I Inch Clipless (Jax Beach Series) • • • . .... . .. .... Using two tape measures,locate Point C ••• • s' by hooking one tape measure to Point A. +•••• • and the other tape measure to Point B, :, • • •••• • then extending both tape measures until , .. ;•+••• • • they cross at the 4ft and 5ft increments •••• • (shown here).Then place a temporary nail • • •••• • • • °' at this intersection. • tThese are the 4ft and 5ft sides N Cthe 3...4...5,..Triangle. M y r ` � O V M. 1 2 3 1 Establish a line from Point A to Point B by temporarily marking each point with a nail.The line must be parallel to the eave and in this example aft Long(This is the "3"side of the 3...4...5...Triangle). a Connect a chalk line to Point A's nail and then pull it to Point C's nail.Then mark your chalk like on the roof deck. This is your square reference line for your panel installation: O ��TI (A O 'o q' NOTE: a mss? 41 For larger distances just multiply each ' side of the triangle by the desired size. x ' For instance if the Eave to Ridge height is 25ft then multiply each side by 6 to get an 18...24...30...Triangle. r SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE §unlastMetal Page 11 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL=6 FACSIMILE: (772)781-7492 " PRODUCT 1 / I Inch Clipless (Jax Beach Series) Use two tape measures,on at the ridge • •• • • and eave'ends of the Square Reference • .. • :••• Line and measure out 1 foot past 3 panel • • • • wide,or up to a maximum of 10 feet. • • • •• •••• • Then hammer another temporary nail at • •••• ' • •••• the eave and run a chalk line to the ridge • •••• •••••• •••• at the same length. . •.•• • • 1 21 3 4 - 5 6 7 9 1 • " • • " • • O O O � y M o V M 1 2 3 4 5 61 7 81 9 , 10 ` i !4 5 Check for square by measuring the distance from each installed panel edge to the chalk line at both the me and ridge. If the q _ measurements do not match,then the,, installed panels are not square and need to be adjusted.Be careful not to cause oil canning 1 2 when attempting to adjust panels. F t M 1 1 1 y�..�2y\1 �.. t . SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE i t §unlastMetal Page 12 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)'781-7492 "PRODUCT IN1 1 I Inch Clipless (Jax Beach Series) INSTALLATION SEQUENCES • • • ••• .• x l , ' ••••• o,\�/ f • • 1. Moisture Barrier- Install 2. Fascia Trim- Install the fascia trim 3. Eave Trim- Install the Eave-rrim Moisture Barrier according to the along all eaves and rakes. along all eaves lapping over Fascia manufacturer instructions. Trim. k ' t 1 4.Valley Trim - Install the Valley 5. Metal Roof Panels-Install the 6. Hip Trim- Install the Hip Trim over Trim over the Eave Trim, working panels over the Eave and Valley Trims. the'Metal Roof Panels just installed. ` from the Eave to the Valley Peak. Do not install panels where the trim laps under the panels. h v 7. Ridge Trim - Install the Ridge 8.Transition Trim - Install the Transi- 9. Metal Roof Panels-Complete the Trim over the Hip Trim intersection tion Trim over the low slope panels and panel installation -installing the high and val.ley peak. moisture barrier. panels over the Trim Transition and the { remaining exposed locations. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE d §unlast Meta/ Page 13 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT 1 / ► 1 I Inch Clipless(Jax Beach Series) INSTALLATION SEQUENCES - CONTINUED .. � •_ tet\ • • \ `�/ ��! v� /�\ •�/••• N/• i••• 10: Rake Trim - Install the Rake 11. Peak Trim - Install the Peak Trim 12. Ridge Trim -Install tf a Ridge Trim Trim over the panels along all Gable over the panels. over the Panels. Rake edges. i 13. Side Wall Trim - Install Sidewall 14. Side Wall Trim (Rear View) 15. End Wall Trim - Install End.Wall Trim over the panels. Trim over the panels. I I r SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE unlastMetal Page 14 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INF1 1 I Inch Clipless (Jax Beach Series) FLASHING / TRIM METAL DETAILS Y BULLNOSE EAVES DRIP BOX GUTTER (6't.&TANQARD) i 0000•• • • •• 411 3/411. • 1 ' 2-1/2" ... .. ..... 2-1/2" ....5': .. .. • • ••• • • •0 •• • .0000. . • •• L0 a 0 •" 611 y S.O. = 8" S.O. =22-1/4" (Standard) r GABLE RAKE PEAK / HIGH END FLASHING - 3-3/8" �1 5' \-3/4" 1/2" 3-1/2" 5 r S.O. = 5-1/8" S.O. = 11" GAMBREL FLASHING TRANSITION FLASHING 6" r 6" S.O. = 12-3/4" S.O. = 12-3/4 SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE gunlastMetal Page 15 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6• FACSIMILE: (772)781-7492 ' PRODUCT 1 ► 1 I Beach FLASHING / TRIM METAL DETAILS (cont.) RIDGE / HIP CAP (HEMMED) VALLEY ., • .... . 5-114" " •••• 000000 , ... . 11 ..... 314"Hem 9 •.. : 9.:.. . .... . 00 r S.O. = 12" S.O. = 20" SIDEWALL FLASHING . END / HEAD WALL FLASHING 4" 4n 511 3/411 3/4. S.O. = 9-3/4" S.O. = 9-3/4" r MO. Flashing/Trim Details STUCCO STOP ' •-- 2 v: 3/8�� Gable Cleat v:. 2 U2-1r 1 Valley Cleat 2 Y.„ R { SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE a Page 16 ,. . EDBN SS • • • • • t i r 2" = Cleat #10 x 1" Pancake-Head Wood Screw 'Bullnose Cleat Sunlast Metal, In'c. DRAWN #30 Felt (Min.) Name JAR Eave Drip -. SS Name JR (Bullnose) ENGINEER Plywood Decking (15/32" Min) Name JARSIZE ; DWG NUMBER Name ED JR A EDBN-SS SCALE 2: 1 REV A ISHEET 1 OF 1 i Page 1.7 BG1 -SS 0000.. 0000.. 0000.. . . 0..4 0 0000.. .. . 0000 .. . 0 . 0000 .. .. 00.00. .. 0.00.0 .. .. 0 .. . 0 . 0 :60:6: 0000 . 0000.. 000 0000 . .. 0 ... . #10 x 1" Pancake-Head Wood Screw. 1/8" x 3/16" Stainless Steel Pop Rivet Box Gutter Strap (Sized to Gutter) Box Gutter (6" x 6" Standard) Sunlast Metal, Inc. Name JAR #30 Felt (Min.) Name D JR Box Gutter 1 - SS ENGINEER Name Plywood Decking (15/32" Min) APPROVED JAR SIZE DWG NUMBER Name JR A BG 1-SS' SCALE 2:1 REV A ISHEET 1 OF 1 Page 18 G .R1 - SS, 0 . E, •• . :600:6 • *Do:* 0 :0,90 ... . . .. .. . • ..... . . ... ...... :;�psfJrB I=5d8 Gable Cleat 2-1/21' IvE #10 x 1" Pancake-Head Wood Screw 1/2" Buytl Tape Sealant E Pop Rivet (Stainless Steel) Sunlast Metal, Inc. k #30 Felt (Min.) Name JAR Name° JR GABLE RAKE 1 - SS Plywood Decking (15/32" Min) NameER AJAR sizE DWG NUMBER Name ED JR A GR1-SS SCALE 2: 1 REV A SHEET 1 OF 1 I ' 6 Page 19 PF—SS • . • • •• • • • • so* ** 0. : 6016 • *::::* • •• • 0#0000 0 0 OP004 000000 :sees* ,so 0 • • else: 0 :see:* / • • • • / • • • • •• • • 0 00: #10 x 1" Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z=Closure 1/2" Buytl Tape Sealant Sunlast Metal, Inc. DRAWN Name JAR CHECKED #30 Felt (Min.) Name JR Peak Flashing - SS ENGINEER Name JAR SIZE DWG NUMBER Decking (15/32" Min.) Name ED JR A PF-SS SCALE 2:1 REV A TSHEET 1 OF 1 3 Page 20 PF2 —Ss 4040.... .0 . 0 a pool 4040 . . . • 4040.. . . . ,• . 4040 4040 • 4040 . / f 4040.... 4040 . . f 4040 . f . •4040•.• • . • 0 6004 • 0404 • • • •• 17 1 y . 4040 #10 x 1"Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z-Closure 1/2" Buytl Tape Sealant Sunlast Metal, Inc. Name JAR #30 Felt (Min.) Name D JR Peak Flashing2 SS ENGINEER Name JARSIZE DWG NUMBER Decking (15/32" Min.) Name ED JR A PF2-SS SCALE 2: 1 REV A ISHEET 1 OF 1 Page 21 GF1, -S-S ...... . . . .. z i [ Rid r dd r i #10 x 1" Pancake-Head Wood Screw Buytl Tape (1/2" Min.) Sealant Z Closure Sunlast Metal, Inc. #30 Felt (Min.) Name JAR Name D JR GAMBREL ' Plywood Decking (15/32" Min) NameER JAR FLASHING '1 (SS) SIZE DWG NUMBER Name ED JRi A GF1-SS SCALE 2:1 REV A SHEET 1 OF 1 ! Page 22 t TF1 —SS k Z=' � 5IAF �'�1 • ... .. 040 0 04 ••• • . . 7 #10 x 1" Pancake-Head Wood Screw 1/2" Buytl Tape Sealant Z-Closure Sunlast Metal, Iric. #30 Felt (Min.) Name JAR ' CHECKED TRANSITION Name Plywood-Decking .(15/32" Min) -ENGINEER JR FLASHINGf1 (SS) Name JAR s¢E DWG NUMBER Name ED JR A TF1-SS SCALE 2: 1 REV A SHEET 1 OF 1 I , Page 23 RHC-SS t . .. . . 004. [,osur.49 y16 r�, #10 x 1" Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z-Closure 1/2" Buytl Tape Sealant Sunlast Metal, Inc.- f DRAWN Name JAR #30 Felt (Min.) Name° JR Ridge/Hip Cap - SS ENGINEER Name JAR SIZE DWG NUMBER Decking (15/32" Min.) Name ED JR A RHC-SS SCALE 2: 1 1 REV A SHEET 1 OF 1 l r t t Page 24 v 1 ss 0000.. 0 •. . 0000.. 0000.. .. • 0000.. 0000 .. 0 0 0 0000 • . 90 0 a . . .. 0. 0 .000. Ile 3/8" Valley Cleat #10 x 1" Pancake-Head Wood Screw Valley Cleat Butyl Tape Sealant Sealant Sunlast Metal, Ift. DRAWN Name JAR #30 Felt (Min.) Name° JR Valley 1 - SS ENGINEER Name JAR SIZE DWG NUMBER Plywood Decking (15/32" Min.) Name E� JR A V1-SS SCALE 2: 1 REV A I SHEET 'I OF J Page 25 swi SS' • •• •• • . .: •.•••. • • • • 01000: •..••• • • • •• • � f . R J i �• I i #10 x 1" Pancake-Head Wood Screw r Buytl Tape Z-Closure Stainless Steel Pop Rivet Sunlast Metal, Inc. Sealant DRAWN Name JAR ' CHECKED Side Wall 1 - SS #30 Felt (Min.) Name JR ENGINEER t Name JAR SIZE DWG NUMBER .Plywood Decking (15/32" Min.) Name ED JR A SW1-SS SCALE 2: 1 REV A SHEET 1 OF 1 t , Page 26 SW2 _ _ SS ■ 114" 112" 2,... Counter Flashing h 1/4" 2" •••••• Closed Hem ' ' "' •• •• • • #10 x 1" Pancake-Head Wood Screw , =,s #10 x 1-1/2" Hex-Head Wall Screw (Counter Flashing) Counter-Flashing (5-1/2" S.O.) Buytl Tape Z-Closure Stainless Steel Pop Rivet Sunlast Metal, Inc. Sealant DRAWN . Name JAR Name D JR Side Wall 2 - SS #30 Felt (Min.) ENGINEER Name JAR SIZE DWG NUMBER APPROVED S /►12-SS Plywood Decking (15/32" Min.) Name 2:1 JR REV A SHEET 1 OF 1 } r Page 27 EW1 SS s f • r 1 F I � r #10 x 1•" Pancake-Head'Wood Screw Buytl Tape Z-Closure Sealant Sunlast Metal, Inc. DRAWN #30 Felt (Min.) NECKED JAR Name JR End Wall 1 - SS ENGINEER Name Plywood Decking (15/32" Min.) APPROVED JAR SIZE DWG NUMBER Name JR A EW1-SS SCALE 2:1 REV A SHEET 1 OF 1' 1 Page 28 EW2 SS je /4" 1 Counter .000.0 ... .. :0.0:. Clo • • 000600 •• •6 6 ..0 0 ' 0000• 0000• • •• ••••••• • • • • • • • •0060• Goo :0 ••6••• • 0006•• • • • • • 6 • ••• •• •• #10 x 1" Pancake-Head Wood Screw -' #10 x 1-1/2" Hex-Head Wall Screw (Counter Flashing) Counter-Flashing (5-1/2" S.O.) Buytl Tape Z-Closure SealantSunlast Metal, Inc. DRAWN Name JAR Name D JR End Wall 2 - SS #30 Felt (Min.) ENGINEER Name JAR SIZE DWG NUMBER APPROVED E\A/2-C�C� Plywood Decking (15/32" Min.) Name JR A VV SCALE 2:1 REV A SHEET 1 OF 1 t i• 1; i Y- Bostiksmart I r adhesivesi, i 70 � 05A HIGH QUALITY ADHESIVE AND SEALANT • • • _•,•,..Fes.� .. ..-. • ••• • .. ;f High strength F •0 0600%,Good`adhesiori 0 0 ;••••0 • Pr"erless • • •• ••••• DESCRIPTION ' • 70-OSA is a Silyl Modified Polymer(SMP)based adhesive with ••••• a higher green strength and higher tensile strength as 70-OSA' •••••• • • • /70-03A and is suitable for making elastic constructive Joints. FEATURES Solvent,isocyanate,and pvc-free —• • • ;. fit. Very good UV-resistance and ageing properties In general,good adhesion on several substrates without • • . •the use of a primer q0escilptlin, Results Permanent elastic within temperatures from-40°F to 248°F(-400Gto+1200C) Basic Material 5Hyl Modified Polymer e Neutral,odorless and fast curing Curing Method Moisture Paint compatible with most Industrial paint or lacquer Specific Gravity Approx.1.5 g/ml systems,both alkyd resin and dispersion based(due to the Skin Forming Time large scale of,differenttypes•ofindustrial paints apaint (70•F/20•c@50%R.H.) Approx.10 min. compatibility test is recommended) 0 enTime Pain table after skin forming(wet-on-wet);this will not (70•F/20•C050%R.H.) <15 min. Influence the cure rate. Curing Speed After 24 hrs. (70•F/20•C@50%R.H.] 0.125-in(3mm) APPLICATIONS Elastic bondings Shore A Hardness and seatingsi bus,caravan,train and Approx.60 (DIN 53505) truck construction . • Bonding of roofs on busses,trains,trucks Volume Change <3% (DIN 52457) ' Bonding of corner profiles of aluminium or i polyester on trailers Green Strength (Physical,Rheometer (maximlmloadwhichcanbe 500 Pa(Ph Y i Bonding of polyester parts on metal frames applledperm'uncuredadhesive MC100) l wlthoutsagging) Bonding of floor systems Tensile Stress(100%) 390 psi(2.7 MPa) ADHESION (DIN S3504/150 37) In general,70-OSA adheres well without primer on clean, Tensile Stress at Break 'dry,dust and grease free substrates of aluminium,stainless (DIN 53504nso 37) 500 psi(3.5 MPa) steel,galvanised steel,zinc,copper,brass,powder coated metal,most lacquered metal surfaces,glass,PVC,polyester Elongation at Break 200% (DIN 53504/150 37) 1 i • PACKAGING o-Dese'ripti'on. Results For packaging options please call your Bostik sales or - - technical representative. i ' Shear Stress i Atuminum-to-Aluminum SHELF LIFE Adhesive Thickness 2mm 435 psi(3.0MPa) 70-05A may be stored for 12 months in a closed(unopened) Test Speed 50 mm/min (DIN 532e3/ASTM D1002) container in a dry place at temperatures between 41°F to 86°F(+5°C and+300C);(cartridges 18 months), i Tear Propagation Approx.17 N/mm HEALTH AND SAFETY PRECAUTIONS- ! E-Modulus(10%) 700 psi(4.8 MPa) Nospecific safety precautIo6s required.Please refer to the SDS for complete details. Temperature Resistance . -40°F to 248°F(-40°C to 120°C) LIMITED WARRANTY F Temperature Resistance 356OF(180°C)(max1/2hr) Limited Warranty found atwww.bostik-us.comorcal0 • 800-726-7845.TO THE MAXIMUM EXTENT ALLOWED 6••••• Application Temperature 41°F to 95°F(5°C to 35°C) BY LAW,BOSTIK DISCLAIMS ALL OTHER EXPRECS OR • ••••:• IMPLIED WARRANTIES,INCLUDING WITHOUTLIMITATIOM••06 •6 66666 1000600 UV and Weather Resistance Excellent WARRANTIES OF MERCHANTABILITY�"D P•I CESS FOR A • ` 6 PARTICULAR PURPOSE.UNLESS OTHERVI%%STATED IN THE• ••'6• Colors(Standard) White,Black LIMITED WARRANTY,THE SOLE REMEDY EQI�DREACH OF•6 of • WARRANTY IS REPLACEMENT OFTHVggpy�TORRFFUND • • • •666• OFTHE BUYER'S PURCHASE PRICE.BQ.%1%g1SCLAIMjffl"•• 16666• LIABILITY FOR DIRECT,INCIDENTAL,CpV"Q4ENTIAL,OR 6. 6• (GRP),painted and lacquered wood,etc.No adhesion on SPECIAL DAMAGES TO THE MAXIMUM:EXTEN jALLOWgD BY. ••6• 6 untreated polyethylene,polypropylene and PTFE.In those LAW.DISCLAIMERS OF IMPLIED WARMNT14 MAY NOTE •• cases where due to greatthermal or physicalloads,especially APPLICABLE TO CERTAIN CLASSES 0rasANDSqNFi ••6.666• . • 6 • under wet conditions,high adhesion demands are needed, STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION '•; the use of Primer M is recommended.Primer M is a so called OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE "wash primer"and degreases and•prepares the surface of the ABOVE LIMITATIONS MAY NOT APPLY TO YOU.It is the buyer's substrate in one step.On plain,untreated wooden surfaces obligation to test the suitability of the product for an and other porous substrates Primer P is recommended. • intended use prior to using it.The Limited Warranty extends For more details concerning Primer M and Primer P consult only to the original purchaser and is not transferable or the specific technical information data sheet.For substrates assignable.Any claim for a defective product must be filed not mentioned and for additional information consult Bostik. within 30 days of discovery of a problem,and must be METHOD OF USE submitted with written proof of purchase. 70-05A can easily be extruded with a hand-or air pressure gun at temperatures between 41°F to 95°F(+5°C to 35°C).In seating applications 70-05A should be tooled or smoothened I within 10 minutes(70°F/200C @ 50%R.H.)with a spatula or Putty knife,occasionally moistened with a soap solution. Avoid soap solution penetrating between Joint sides and sealant,because this will create loss of adhesion.In bonding applications,the substrates have to be assembled within 15 minutes(700F/200C @ 5096 R.H.)after applying 70-05A.In general an adhesive thickness of 2 mm Is recommended. At a temperature of 70°F(20°C)and a relative humidity of 50%,70-05A can be painted with the most industrial paints 10 minutes after application.Best adhesion of paint coats is - generally obtained if painted within 4 hours after applying • • 70-05A.Cleaning tools or removing uncured residue of 70- rn 05A can be done with a clean colorless cloth,wetted with eo20 W Inc. 11320 W Watertown.Plank Road } Isopropylalcohol.It is recommended to make a trial firstto Wauwatosa,WI 53226 check possible attack of the substrate by Isopropyl alcohol. www.bostik-us.com This document supersedes all previously published literature. 12.16.14 i I I� c i i F J i �MIAMI-DADS MIAMI-DADE COUNTY 1 62'l'J11Jv PRODUCT"CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175;2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315=2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamldadLgov/economy Bostik,Inc. 11320 W.Watertown Plank Road Wautivatosa,WI 53226-3413 •""' SCOPE: ...... This NOA is being issued under the applicable rules and regulations governing the use ofooiretiruction materials.The documentation submitted has been reviewed and accepted by Miami-Dade•Ceenty RER-- •• Product Control Section to be used in Miami Dade County and other.areas where allowefty the •• ••••• Authority Having Jurisdiction(AHJ). 00 so""" ...... This NOA-shalt not be valid after the expiration date stated below.The Miami-Dade Courttr product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Aade C+ountyl•• ••• • reserve the right to have this product or material'tested for quality assurance purposes.T'thVlaroduct ;• ••; y. or material fails to perform in the accepted manner, the manufacturer will incur the expMse bf sucli••• • testing and the AHJ may.immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High VelocityHurricane Zone of the Florida Building Code. DESCRIPTION: Bostik 915/915RT Sealant f LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miarni-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product.F TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or.manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of: NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any•portion of the NOA is displayed,then it shall be done in its entirety: INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its t distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.13-0423.10 and consists of pages 1 through 3. j The submitted documentation was reviewed by Jorge L. Acebo. t 1 NOA No.: 17-0329.18 Expiration Date: 05/24/22 CMIAMI-DADE COUNTY Approval Date: 05/04/17 Page 1 of 3 r tROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Cement-Adhesive-Coatings Materials: Polyurethane SCOPE: This approves Bostik 915/915RT Sealant as manufactured by Bostik,Inc.as described this Notice of:...:. Acceptance.This product has been designed to comply with the Florida Building Code,nclApg the' High Velocity Hurricane Zone of the Florida Building Code. •••'••• • PRODUCT DESCRIPTION: .... .. . . . . . .... . .. ..... Bostik 915/915RT Sealant • ...... . . ..... Property Standard ResiAW•• ...... Tensile Strength @ 73' ASTM D412 161. s�•••• i • Elongation @ 73' ASTM D412 800'/0 ;;.. ••'••• Modulus of Elongation ASTM D412 Tear Strength ASTM D624 36 plir Adhesion Peel ASTM C794 29.2-38.4 pli Hardness(Shore A)_ ASTM C661 32.5 UV Resistance ASTM C793 Pass Note: The physical properties listed above are presented at typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. ' EVIDENCE SUBMITTED: Test Agency Test Identifier Test Specificatioh Date Momentum Technologies,Inc. EX201)6C TAS 132 07/19/06 NX02E2A TAS 132 03/15/13 MANUFACTURING LOCATION: 1, Conyers,GA BUILDING PERMIT REQUIREMENTS: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. t NOA No.: 17-0329.18 MIAMI•DADECOUNTY Expiration Date: 05/24/22 Approval Date: 05/04/17 Page2 of 3 a i XdMITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials 'Directory for fire rating of this product. 2. . Bostik 915/915RT Sealant shall not be applied in inclement weather conditions. 3. The products listed herein are components of roof assemblies and are approved for use with roof I ssemblies that list the products listed herein as part of their roof assemblies Notice of Acceptance. See roof system Notice of Acceptance(NOA)for application rates and uses. :*@, *:* 90000.. 4. All products listed herein shall have an unannounced follow-up quality control program From au .' approved listing agency. Follow up test results shall be made available to Miami-Dodo-County: Product Control upon request. "'••• • 0000.. 5. Change in materials,use,or manufacture of any products listed herein shall be cautre f.o14tezmiTtivp,• • of this Notice of Acceptance. 0 0.6 9. 00:00' 0000.. 6. Bostik 915/915RT Sealant shall be applied in accordance with manufacturer's pu]5!slw application ••••;• instructions unless specified otherwise within the NOA approvals. ' . . . . 09000. 7. All products listed herein shall have a quality assurance audit in`accordance with the Florida :""' . Building Code and Rule 61G20-3 of the Florida Administrative Code. •• ... :" 8. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name dr'logo,city,state and following statement: "Miami-Dade County Product Control Approved or the Miami-Dade County Product Control Seal as shown below. IIA,�M4DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 17-0329.18 CECOUNTY Expiration Date: 05/24/22 MIAMWAD•� Approval Date: 05/04/17 Page 3 of 3 i , 0- Bostiksmart adhesives i I 9145 i f i I i i i HURRICANE N�18mi D'ad ea{pProved l •••••• �••••• •••••• i - f !SBonds•tvdfzukusrate � ng 082dh1eta15 • nostl<;'ha T •• { • • • • •••••• -0 tstanding,%0ndlmg,and_ ' •ad hesive;�qualitles- •�� { DESCRIPTION Bostik'915 sealant is a one-component;smooth polyurethane adhesive capable of dynamic joint movement totaling 70%of original jointgeometry(f35%).The sealant cures to a tough,flexible rubber when exposed to moisture present in the atmosphere. Bostik915 all seasons formula has physical properties that will remain relatively stable over time.The cured performance temperature range Is, -40°F to 150°F. Where textured appearance Is needed,please use Bostik 916 or Bostik 2000T. APPLICABLE STANDARDS MIAMI•DADE COUNTY ASTM C920,TYPE S,GRADE NS,CLASS 35 USE NT,A AND M VT . . US Federal Specification TT-S 00230C (COMB-NBS) for one-component sealants as Class A,non-sag i CARB,SCAQMD;and OTC compliant testing procedures.It is recommended that adhesion testing Canadian Specificatlon CAN/CGSB 19.13-M87 be performed to capture batch control qualities of proposed Miami-Dade County,Florida,NOA No.:13.0423.10,05/24/17 substrates. Miami-Dade TAS 102-Static UpliftResistance Joint Design: In general, more joint movement can be AAMA 808.3 accommodated In a thin bead of sealant than a thick bead. AAMA 100/200/300 installation requirements Bostik.915 should be no thicker than 1/2" (12.7mm) and no thinner than 1/4"(6.4mm). In joints between 1/2"and 1",the BASIC USES ratio of sealant width to depth should be approximately 2:1. Bostik 915 is designed for applicatlons from foundation to finish Sealant depth in joints between 1/4"and 1/2"should be 1/4" and is ideal for,seating expansion and control joints,tilt up joints, deep.Joints with'dynamicmovement should not bedesigned perimeters of doors, windows, and other wall penetrations. in wldths less than 1/4". It has tenacious sealing and bonding performance for many . Surface Preparation: See limitations about surface roofing applications,metal roofs,gutters,roof tile installations, preparation.Surfaces must be structurally clean,dry(no frost) flashing and sheet metal applications. and structurally sound,free of contaminants, including, but. Bostik 915 cures to form a durable, flexible bond with most not limited to,dust,dirt,loose particles;tar,asphalt,rust,mill building materials such as stone,foam,masonry,ceramic,wood, oil,etc.If substrate is painted or coated,scrape away all loose steel,Kynar coated metals and.copper and most other metals. and weakly bonded paint or coating.Any palnt'or coating that cannot be removed must be tested to verify adhesion of the INSTALLATION PROTOCOL sealant or to determine the appropriate surface preparation if Miami-Dade County Considerations:. Mate or join adjacent needed.(See ASP section on next page for details.) surfaces prior to the Bostik 915 skinning and subsequent curing, To remove laitance and any other loose material, clean to maximize wetting potential of the sealant to the substrates. concrete,stone or other masonry materials with non-alcoholic Allow full-cure,typically 7 days,prior to any mechanical stress i t ' I i 1 CAUTION MANDATORY • • • I HARMFUL IF SWALLOWED OR INHALED.CONTAINS POTENTIAL I-FIELD TEST ! SENSITIZER. MAY CAUSE ALLERGIC SKIN OR LUNG REACTION, MAY IRRITATE EYES,SKIN AND RESPIRATORY TRACT.Methanol i' ( � may form during curing.Do not breathe fumes.Do not get in Y , 1 eyes,on skin.or on clothing.Use with adequate ventilation or �o +,rKNIFE,CUTi' wear mask:Wash thoroughly after handling.Store container in n 'NBOTH•Sil)ES a cool,dry area with lid tightly seated.Do not reuse container. rBACKER KEEP OUT OF THE REACH OF CHILDREN IROD 4 1c► j APPLICATION LIMITATIONS �r I 'SEAL:ANTs Construction substrates have become complex and diverse by -� �� ,Il aMUSTR MAIN nature and origin. Substrate chemistries and structures can TH:SIDES I interfere with adhesive performances of the sealant.Adhesion t to Substrate Pretest(ASP)is therefore MANDATORY to assess any 17 adhesion and seatingcharacteristics—see Adhesion to Substrates "` • • i Pretest section and see Installation Protocol section.This must • • • ••••.. be done pre-installation to avoid potential failures.Call Technical 4 --��"'°* • • • •• • I Service for mope information about surface preparation and ....•• . •..•.. possible priming. During the curing of Bostlk 915,do not wpxe io.curing silicone • . i Do not apply over damp, contaminated, loose surfaces (See sealants,curing Bostik PRO-MS 50,Bostik*WQQ or Bost!62,020;• ;••••; Installation Protocol and Surface Preparation), old sealants or alcohol,acids or solvent-based materials.....• ; •..' ...• other foreign substances that may impair the adhesion bond.Avoid Compatibility to copper-based substr4t*%y,e.,flashing) can, ••;••• air entrapment. vary due to,but not limited to,age and jpjpt�q?Please(:MARt•• •••••• Dampness and substrates with high moisture content will trigger Technical Service for details. •••••• • •• extensive curing of the sealant within a very short period of time. Lower relative humidity and temperature•wilt slgniflcantly • This may cause an excess of bubbling and foaming within the extend the curing time.Confined areas,dee joints and meleb""• •••••• sealant and at the bottom of the bead, barrier substrates may also affect the full curetirne and extend it :....: High temperature/humidity can cause the sealant to develop by many days.Apply sealant in ambient air temperature of ad-.F : • • bubbles during the curing process. (4.46C).and rising. •• Sealant installation is not recommended when the dew point of Bostik 915 may remain tacky for a few hours and attract dust the substrate is close to ambient temperature or a moisture-vapor and dirt from the jobsite which may affect the appearance of the transmission condition is present Increasing the potential for sealant.Check tack-free time to prevent dirt pickup. bubbling to form during cure. Bostik 9151s not recommended for glazing applications.Bond line Porous substrates such as,but not limited to,marble,limestone, strength can be affected by UV rays through the clear material and granite might absorb components of the Bostik 915 leading to (glass,acrylic glass,polycarbonate,etc.). j staining of the substrate.ASP with sufficient aging is mandatory Bostik 915 is not an RTV silicone and therefore is suitable for to assess this potential issue, painting with latex based paints.Paint chemistries and flexibility The ultimate performance of Bostlk 915 depends on proper joint characteristics of the paint films over the sealant may affect ! design and proper applicationwith joint surfacesproperty prepared wetting, adhesion and Integrity of the paint layer; and it Is j (See Installation Protocol),Bostik 915 Is not recommended forJoints therefore mandatory to pretest the paint or other coating over with dimensions less than or greater than what is recommended the Bostik 915 to ensure the successfulcompatibilitybetween the below.(See Installation Protocol—Joint Design section.) , sealant and the paint/coating after a sufficient amount of time. Bostik 915 must not be used to seal narrow joints,fillet joints and See your paint manufacturer for specifications or limitations and t face nail holes. call our Technical Service for more information.In general,oil- Smearing and feathering Bostik 915 over joints is based paints are not recommended because of their poor elastic not recommended. properties and because of their potential interaction with the Bostik 915 is not recommended for horizontal joints or traffic-bearing sealant chemistry,which may create non-curing conditions for joints where abrasion resistance Is required (walkways, driveways, the sealant.Do not paint over the polyurethane sealant until it runways,etc.).Please refer to Bostik 955-SL for this application. has fully cured. Bostik 915 is not recommended for continuous Immersion in The surface of a Bostik 915 seal when exposed to UV rays and water or any other fluid.When fully cured,avoid exposure,even sunlight wlllyellowand wilt not retain Its gloss.This phenomenon Incidental,to fuels,chlorinated,acid and alkaline solutions.Bostik can occur within a few weeks after exposure.The change of 915 is not recommended for exterior or Interior sealing below color is limited to the surface layer of the seal and should not the waterline; please refer to Bostik 940 Fast Set for marine compromise the.sealing� g properties of the Bostik 915 if the applications. . dimensions of the joint are proper and the sealant is otherwise Contact of Bostik 915 with asphalts(i.e.,back coating of window properly applied.In areas where color retention is critical,please flashing,etc.)and other filler compounds Impregnated with oil, refer to Bostik 2000,Bostik 2020 and Bostik PRO MS 50.Bostik asphalt,tar,etc., may deteriorate the cohesive strength of the 915 may remain tacky for a few hours and attract dust and dirt substrate and ultimately compromise the seal,Please refer to PRO from the jobsite which may affect the appearance of the sealant. I MS 50 for asphalt applications. Check tack-free time to prevent dirt pickup. Y 1 I 1 i i' PRIMER COVERAGE RECOMMENDATIONS W idth For one•quort ofprimer;coverage'is as fo_Mows'. ,a 49 181unit 5gallonpall 33 24 20 16 14 12 5 units 1.5 gallon unit 1/4" .1 24 20 12 10 8 7 6 7 gallons 1 gallon unit 3/8;' 11 8 6 S 5 4 6 5 4 3 3 'All values are approximations and can vary due to Joint dimension variations, of substrates.Yield per cartridge ariations,porosity,and texture Linear Feet Per 10.1 FL.OZ.Cartridge Is approximate due to variables beyond Bostik's control,such as irregularJoint configuration and Installation technique. ,COVERAGE FOR 20 FL.OZ. (600ML).S U Width pro ert WaLUe, tTeJ stl.Mathod/Note �. r• Tool/Work Time 60 min. Bostik Test Method Depth 1/8" 1%4" •378 1/2.'x' . 4 ' —"` " Skin Time 4 Hours Bostik Test Method••••• 1/8.-T 288 145 95 71 58 48 40 36 •••••• 1/4 71 58 36 29 23 20 17 Curing Time @77°F(25°C) 2-7 days VaTI84 O/reiative h*Idity• •• 32 23 17 16 13 11 Flow,Sag or Slump 0.3 Inch BeetNt 00 Methal •• •• •i• y 17 14 11 10 8 'Values given above are not intended to be us*Mn specification • ;••••; , preparation purposes. •••• •• • • • Linear Feet Per 20 fl.oz.Sausage • • • • • • •• 0000• i 0000• ! • • • 0000 • COVERAGE •• • • 0000•• ' '' • Kati]ri .. _ r..-. �� .ry,,.tr,.r.p� , • �^,r,� .•.}r Jr n_r.b. s.,, • 1IdEh Property: Value, if M'e od%Note • De th 1/8 1%4" +3%8" 1%2" 5/8;x' 3%4" 7/B" 1;` � i � � �•:•:• 0009•• P ...i�r3 . L�- Hardness(Shore A) 42 ASTM 82240 • 1/8" 6150 3100 2050 1540 1230 1025 870 770 Modulus @10096 Elongation 65 psi A9T�1 D 412 ••• • :• • 1540 1240 770 615 510 440 370 @ 25%Elongation 45 psi ASTM D 412 •• 3%0! 680 510 410 310 290 245 Tensile Strength @ Break 133 psi ASTM D 412 370 305 245220 185 _ Elongation @ Break 685% ASTM D412 Linear Feet Per S Gallon Pail Adhesion Peel >5 piw TT-S-00230C/ASTM C 794 i l Joint Movement Capability +/-35% TT-S-00230C/ASTMC719 LIMITED WARRANTY UV Resistance Pass ASTM C793 . The Limited Warranty for this product can be found at StaticllpleteiftResistance www.bostik-us.com/resource-center/warranties or by Static(concUplift Retile)sist 49 Miami-DadeTAS102 calling 1-800-726-7845 (choose option 2, then option 2 again). TO THE MAXIMUM EXTENT ALLOWED BY LAW, 'Values given above are not intended to be used in specification BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED preparation purposes. WARRANTIES,INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR ` PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED WARRANTY,THE SOLE REMEDY FOR BREACH OF WARRANTY IS REPLACEMENT OFTHE PRODUCTOR REFUND OF THE BUYER'S PURCHASE PRICE, BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT,INCIDENTAL,CONSEQUENTIAL,OR SPECIAL DAMAGES # TO THE MAXIMUM EXTENT ALLOWED BY LAW. DISCLAIMERS iNSTiT k OF IMPLIED WARRANTIES MAY NOT BE APPLICABLE TO MEMBER CERTAIN CLASSES OF BUYERS AND SOME STATES DO NOT BOSTIK HOTLINE ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE ABOVE LIMITATIONS MAY • { 1 NOT APPLY TO YOU. It is the buyer's obligation to test the 1-800-726-7845 2e I suitability of the product for an intended use prior to using it. The Limited Warranty extends only to the original purchaserBostik,Inc. and Is not transferable or assignable.Any claim for a defective 11320 W Watertown Plank Road product must be filed within 30 days of discovery of a problem, Wauwatosa,WI 53226 a� and must be submitted with written proof of purchase. www.bostik.com/us 06.02.16-This document supersedes all previously published literature. t } � 1 i 'r F based solvent by washing, grinding, sandblasting or wire successful compatibility between the sealant and the paint/ t brushing as necessary.Do not use water to clean substrates. coating after a.sufficient amount of time. See your paint Dust must be thoroughly removed after cleaning. manufacturer for specifications or limitations and call our Alcohol is NOT compatible with polyurethanes and its use can Technical Service for more information.In general,oit-based cause irreparable damage to the sealant.if alcohol Is used as paints are not recommended because of their poor elastic a cleaning solvent,all traces of alcohol must thoroughly be properties and because of their potential interaction with the removed prior to the installation of the polyurethane sealant. sealant chemistry,which may create non-curing conditions 1! Lastly,alcohol is not recommended as a tooling medium. for the painted sealant.Do not paint over the polyurethane Backer Rods and Bond BreakerTapes:Bond breakers Including, sealant until It has fully cured. but not limited to,closed-cell polyethylene backer rods are Maintenance: If the sealant becomes damaged, replace the used to control depth of the sealant bead, provide a firm damaged portion by removing the old sealant completely, tooling surface and avoid three-sided adhesion. Where the cleaning the surfaces and reapplying a fresh and appropriate x depth of joint prevents use of backer rods,a polyethylene strip amount of new sealant in accordance with the directiohs and or tape must be used as a bond breaker to prevent 3-sided information contained in this data sheet. adhesion. Do not prime or damage the surface of the bond MANDATORY ADHESION TO SUBSTRATES breaker.Refer to instructions given by rod and tape manufacturers for PRETEST—(ASP) i{ the correct backer rod and tape size related to joint size. A hand pull test must be run before;he}ob•starts and at 0` Priming:In general,application of Bostik 915 does not require •• • • • • priming the substrates. However, some substrates may regular Intervals during the job.It must be run on the job sibe4aft3en• • i •• • •. •..••• I the sealant is fully cured,usually within 7 to 2T a�ays•.(Adhesion may require a Bostik primer.It is the user's responsibility to check .•d• • . • - developfully after at least14 days.)The han putllestprocedure .•.... adhesion of the cured sealant on typical test Joints at the is as follows: •""• 00 `• project site before and also during application as weather 1.Makeakriifecuthorizontaltyfromonesidebrt��JointtothtothLf' 00.00 condit(ons may affect the adhesion results(See ASP section 2. roximati3l chest � 0 PP 9Z�lrE D p9��6• ••..• 111 on next page.).Refer to Bostik Primer product data sheet or Make two vertical cuts athe sides of the joint,meeting the hMofifal cut at the top . 0000•• call Technical Service for proper selection and application of • of the two-inch cuts. •••••• • • i Bostik Primers. • • • • Tooling: Bostik 915 comes ready-to-use.Cut spout or tip to 3.Grasp the two-inch piece of seataAt firmly betwee0 0 0*0 •••••• fingers and pull down at a 90°angle or more,an6try to • • desired bead size.Apply moderate pressure to break seal inside pull the uncut sealant out of the Joln�•0 : ••• . the nozzle. Apply by using a professional caulking gun. Use 4.If adhesion is sufficient,the sealant should tear cohesivety: opened cartridges and sausages the same day they are opened Apply Bostik 915 in a continuous operation using positive in itself. Sealant may be replaced by applying more sealant in the same pressure to the bottom of the joint to properly fill and seal the 5. jmanner as it was originally applied.Care should be taken to joint.When applying, avoid air entrapment and overlapping. Tool the sealant before the skin forms with adequate pressure ensure that the new sealant is in contact with the original,and i that the original sealant surfaces are clean,so that a proper to spread the sealant against the backup material at the , bottom and sides of the joint.A dry toot with a concave profile bond between the new and old sealant will be obtained, Is recommended for that operation.Do not use water or soapy PACKAGING water for this operation.Avoid smearing and feathering of the 10.1 fl.oz.Cartridges,24 Cartridges/Case t sealant to allow full performance of the cured seam.Excess 20 fl,oz.Sausages,12 Sausages/Case sealant should be dry-wiped or joints should be properly taped. 5 Gallon Palls Cleaning:After dry-wiping uncured sealant from substrates 52 Gallon Drums and tools,remaining uncured sealant can be removed by using I Xylene,Toluene or similar aromatic solvents. Please refer to .STORAGE,PACKAGING&SHELF LIFE the SDS'provided for these solvents before use.Bostik Hand Shelf life of Bostik 915 must be checked prior to using the { Towel and Specialty Sealant Remover can also remove uncured product;do not use past its shelf life.Caulk past Its shelf life sealant. Cured sealant is usually very difficult to remove may not perform or adhere as described by this data sheet. } without altering or damaging the surface to which the sealant High temperature and high relative humidity may reduce has been misapplied.Cured sealant can be removed by abrasion significantly the shelf life of polyurethane sealants,if you area. • orother mechanical means(scrapers,putty knives). unsure of the expiration date of your Bostik product,please Curing Time: Bostik 915 is a moisture cure, Polyurethane call customer service at 1-800-7/BOSTIK(1-800-726-7845)to Sealant.On wood,with ambient air at 50%relative humidity check if the product is still within its shelf life. and at 73°F,polyurethane sealants will generally skin within four hours and cure 1/16 of an inch per day.Lower temperature COLORS j and lower relative humidit will significantly increase the skin White Stone Bronze Tan Y 9 Y Black Limestone Md.Bronze Light Gray time and cure time of a polyurethane sealant. Terra Cotta Aluminum Stone Painting and Coating:Bostik 915 is not anRTV silicone and therefore is suitable for painting with latex-based paints.Paint AVAILABILITY chemistries and flexibility characteristics of the paint films Available from authorized Bostik distributors. Go to over the sealant may affect wetting,adhesion and integrity www.bostik-us.com and check on our distributorr locator of the paint layer,and it Is therefore mandatory to pretest for the closest distributor In your location or call customer the paint or other coating over the Bostik 915 to ensure the service at 1-800-7/BOSTIK(1-800-726-7845). t � T 11,_ Bsmart adhesives 1 I r i 9145 l i i HURRICANE . r . * 0000.. 0 0 . 0.00.0 KEYFEATURIES . • . L_B9_6 wK. 0• • •} •de.app0.00••6••.•ndsto difficult,substrates"Ineludin •0000. .4 . ,, 9;ostjKynar.®,coated metals 0000 ..tstanding'bonding and,4 ` 'heslveguallties- 0000.• . . 0000. 6..... •. •. . 0000•• •6...• . . . . .. 660.09 DESCRIPTION •••••• . • 0 . Bostik 915 sealant Is a one-component,smooth polyurethane • • 6666.6 adhesive capable of dynamic joint movement totaling 70%of o ` "`• o ' ' original joint geometry(t35%).The sealant cures to a tough,flexible 0 rubber when exposed to moisture present in the atmosphere. Bostik 915 all seasons formula has physical properties that will remain relatively stable over time.The cured performance temperature range 15 -40•F to. 1501F. Where textured appearance Is needed,please use Bostik 916 or Bostik 2000T. APPLICABLE STANDARDS MIAMI•DADE COUNTY ASTM C920,TYPES,GRADE NS,CLASS 35 USE NT,A AND M US Federal Specification TT-S 00230C (COMB-NBS) for one-component sealants as Class A,non-sag ' CARE,SCAQMD,and OTC compliant testing procedures.It is recommended that adhesion testing Canadian Specification CAN/CGSB 19.13-M87 be performed to capture batch control qualities of proposed Miami-Dade County,Florida,NOA No.:13.0423.10,05/24/17 substrates. Miami-Dade TAS 102-Static Uplift Resistance Joint Design: In general, more joint movement can be AAMA 808.3 accommodated in a thin bead of sealant than a thick bead. AAMA 100/200/300 installation requirements Bostik 915 should be no thicker than 1/2" (12.7mm) and no thinner than 1/4"(6.4mm). In joints between 1/2"and 1",the BASIC USES ratio of sealant width to depth should be approximately,2O. Bostik 9151s designed for applications from foundation to finish Sealant depth In joints between 1/4"and 1/2"should be 1/4" andis ideatfor,sealing expansion and control joints,titt up joints, deep.Joints with dynamic movement should not be designed perimeters of doors, windows, and other wall penetrations. In widths less than 1/4". , It has tenacious sealing and bonding performance for many Surface Preparation: See limitations about surface roofing applications,metal roofs,gutters,roof the installations, preparation.Surfaces must be structurally clean,dry(no frost) flashing and sheet metal applications. and structurally sound, free of contaminants, including, but Bostik 915 cures to form a durable, flexible bond with most not limited to,dust,dirt,loose particles,tar,asphalt,rust,mill building materials such as stone,foam,masonry,ceramic,wood, oft,etc.If substrate is painted or coated,scrape away all loose steel,Kynar coated metals and copper and most other metals. and weakly bonded paint or coating.Any paint or coating that z INSTALLATION PROTOCOL cannot be removed must be tested to verify adhesion of the 1 sealant or to determine the appropriate surface preparation If Mlaml-Dade County Considerations: Mate or join adjacent needed.(See ASP section on next page for details.) surfaces prior to the Bostik 915 skinning and subsequent curing, To remove laltance and any other loose material, clean to maximize wetting potential of the sealant to the substrates. concrete;stone or other masonry materials with non-alcoholic Allow full-cure,typically 7 days,prior to any mechanical stress i ' r' a r' i i C � r I 1 CAUTION MANDATORY ADHESION-TO I i HARMFUL IF SWALLOWED OR INHALED.CONTAINS POTENTIAL SENSITIZER. MAY CAUSE ALLERGIC SKIN OR LUNG REACTION. MAY IRRITATE EYES,SKIN AND RESPIRATORY TRACT.Methanol may form during curing.Do not breathe fumes.Do not get In eyes,on skin or on clothing.Use with adequate ventilation or .a ?. IKNIFE CUT- c .NiBOTH�SI' fi wear mask.Wash thoroughly after handling.Store container in ., , ; - a cool,dry area with ifd tightly sealed.Do not reuse container. +BACKER„ ►d sOF,JOINT' KEEP OUT OF THE REACH OF CHILDREN IR0p CI' APPLICATION LIMITATIONS j ; r I �'"� SEALANT.' Construction substrates have become complex and diverse by , i►l �MUSTREMAIN nature and origin. Substrate chemistries and structures can L ONiBOTH"SIDES_. 1 k Interfere with adhesive performances of the sealant.Adhesion �~ to Substrate Pretest(ASP)is therefore MANDATORY to assess any adhesion and sealing characteristics—see Adhesion to Substrates i Pretest section and see Installation Protocol section.This must be done pre-installation to avoid potential failures.Call Technical + -T -- `''w Or . I Service for more information about surface preparation and • . • .. possible priming. During the curing of Bostik 915,do not expose tc:curing silicone. Do not apply over damp, contaminated, loose surfaces (See sealants,curing Bostik PRO-MS 50,Bosti gWQ or BostICM8•• • �; c Installation Protocol and Surface Preparation), old sealants or alcohol,acids or solvent-based materials.••:•• • other foreign substancesthatmay impairtheadhesion bond.Avoid, Compatibility to copper-based substratesjl*., flashl%pLcang �••••� i air entrapment. vary due to,but not limited to,age and roll jlje!Please Vn%t,• �•••• j Dampness and substrates with high moisture content will trigger Technical Service for details. • • extensive curing of the sealant within a very short period of time. Lower relative humidityand tem er ute will si nfNea�9l • • P �L •• 9 • Y' This may cause an excess of bubbling and foaming within the •""' Y 9 9 extend the curing time.Confined areas, �epl Dims and moisture • I sealant and at the bottom of the bead. barrier substrates may also affect the fuilcure tune and extenck ', t High temperature/humidity can cause the sealant to develop by many days.Apply sealant in ambient air temperature&a% • '•"•• bubbles during the curing process. (4.40C),and rising. : ••• • ; •; Sealant installation is not recommended when the dew point of Bostik 915 may remain tacky for a few Mrs Ind attrV%pt; • • i • the substrate is close to ambient temperature or a moisture-vapor. and dirt from the jobslte which may affect the appearance of th@• j transmission condition is present increasing the potential for sealant.Check tack-free time to prevent dirt pickup., bubbling to form during cure. Bostik 915 is not recommended for glazing applications.Bond line Porous substrates such as,but not limited to,marble,limestone, strength can be affected by UV rays through the clear material and granite might absorb components of the Bostik 915 leading to, (glass,acrylic glass,polycarbonate,etc.). staining of the substrate.ASP with sufficient aging Is mandatory Bostik 915 is not an RTV silicone and therefore is suitable for to assess this potential Issue, painting with latex based paints.Paint chemistries and flexibility ends on proper joint The ultimate performance of Bostik 915 depends P P I characteristics of the paint films over the sealant may affect design and proper application with jointsurfaces property prepared wetting, adhesion and Integrity of the paint layer; and It is i (See Installation Protocol).Bostik915Is not recommended forjoints therefore mandatory to pretest the paint or other coating over with dimensions less than or greater than what is recommended the Bostik 915 to ensure the successful compatibility between the below.(See Installation Protocol—Joint Design section.) sealant and the paint/coating after a sufficient amount of time. Bostik 915 must not be used to seal narrow joints,fillet Joints and See your paint manufacturer for specifications or limitations and face nail holes, call our Technical Service for more information.in general,.oil- Smearing and feathering Bostik 915 over joints is based paints are not recommended because of their poor elastic notrecommended, properties and because of their potential interaction with the Bostik 915 is not recommended for horizontal joints or traffic-bearing sealant chemistry,which may create non-curing conditions for joints where abrasion resistance is required (walkways, driveways, the sealant.Do not paint over the polyurethane sealant until It runways,etc.).Please refer to Bostik 955-SL for this application. has fully cured, i Bostik 915 is not recommended for continuous immersion in The surface of a Bostik 915 seal when exposed to UV rays and ' water or any other fluid.When fully cured,avoid exposure,even sunlight will yellow and will not retain its gloss.This phenomenon incidental,to fuels,chlorinated,acid and alkaline solutions.Bostik can occur within a few weeks after exposure.The change of 915 is not recommended for exterior or Interior sealing below color is limited to the surface layer of the seal and should not the waterline; please refer to Bostik 940 Fast Set for marine compromise the sealing properties of the Bostik 915 if the applications. I dimensions of the joint are proper and the sealant is otherwise Contact of Bostik 915 with asphalts(i.e.,back coating of window properly applied.In areas where color retention is critical,please flashing,etc.)and other filler compounds impregnated with oil, refer to Bostik 2000,Bostik 2020 and Bostik PRO MS 50.Bostik asphalt,tar, etc.,may deteriorate the cohesive strength of the 915 may remain tacky for a few hours and attract dust and dirt substrate and ultimately compromise the seal.Please refer to PRO from the jobslte which may affect the appearance of the sealant. MS 50 for asphalt applications. Check tack-free time to prevent dirt pickup: f i r { based solvent by washing, grinding, sandblasting or wire successful compatlblifty between the sealant and the paint/ brushing as necessary.Do not use water to clean substrates, coating after a sufficient amount of time. See your paint r Dust must be thoroughly removed after cleaning. manufacturer for specifications or limitations and call our j Alcohol is NOT compatible with polyurethanes and Its use can Technical Service for more Information.In general,oil-based I cause irreparable damage to the sealant.If alcohol.is used as paints are not recommended because of their poor elastic a cleaning solvent,all traces of alcohol must thoroughly be properties and because of their potential interaction with the i removed prior to the Installation of the polyurethane sealant, sealant chemistry,which may create non-curing conditions Lastly,alcohol is not recommended as a tooling medium. for the painted sealant.Do not paint over the polyurethane Backer Rods and Bond BreakerTapes:Bond breakers including, sealant until it has fully cured. 4 but not limited to,closed-cell polyethylene backer rods are Maintenance:If the sealant becomes damaged,replace the used to control depth of the sealant bead, provide a firm damaged portion by removing the old sealant completely, tooling surface and avoid three-sided adhesion.Where the cleaning the surfaces and reapplying a fresh and appropriate depth of joint prevents use of backer rods,a polyethylene strip amount of new sealant In accordance with the direction's and j or tape must be used as a bond breaker to prevent 3-sided Information contained in this data sheet. i adhesion. Do not prime or damage the surface of the bond MANDATORY ADHESION TO SUBSTRATES breaker,Referto Instructions given by rod and tape manufacturers for PRETEST=(ASP) thecorrect backer rod and tape size related to joint size. i A hand pull test must be run before the Job starts yid at Priming:In general,application of Bostik 915 does not require : i priming the substrates. However, some substrates may regular intervals during the job.It must bejun onthe job sitJ SfI& • •••••• require a Bostik primer.it is the user's responsibility to check the sealant is fully cured,usually within 7 tdZ'I jl'ays;(AdhesigB may, •• i develop fullyafteratleast 14dayg.)Thehyylpyl�fstprotlert^•• adhesion of the cured sealant on typical test joints at the ••••�• ,, is as follows: . • � project site before and also during application as weather •••••• • conditions may affect the adhesion results(See ASP section 1.Make a knife cut horizontally from one side gfthelointtotheother. ..•... 2.Make two vertical cuts approximately two Iviches to*gq . •• on next page.).Refer to Bostik Primer product data sheet or •••• .. ..... the sides of the joint,meeting the horizontal cut at the top proper PP of the two-Inch cuts. . . . ' •'••• i call Technical Service for ro er selection and application cation o 00.00. Bostik Primers. •• • ••••• Tooling: Bostik 915 comes ready-to-use.Cut spout or tip to 3.Grasp the two-inch piece of sealant firmly betweLn the •••• • i desired bead size.Apply moderate pressure to break seal inside fingers and pull down at a f the JA dr r>•Qre,and try to • the nozzle.Apply by using a professional caulking gun. Use Pull the adhesion Is sealant out of the jnt:h ' ;si••0• •••••• 4.If adhesion is sufficient the sealantshoyjd'f�earcohesively • • opened cartridges and sausages the same day they are opened. •• • ••• • •••• j l in itself. Apply Bostlk 915 in a continuous operation using positive • . j f S.Sealant may be replaced by applying more sealant in the sam•. pressure to the bottom of the joint to property fill and seal the manner as It was originally applied.Care should be taken to joint.When applying, avoid air entrapment and overlapping. i Tool the sealant before the skin forms with adequate pressure ensure that the new sealant is In contact with the original,and i that the original sealant surfaces are clean,so that a proper j to spread .the sealant against the backup material at the bond between the new and old sealant will be obtained. bottom and sides of the joint.A dry toot with a concave profile Is recommended for that operation.Do not use water or soapy PACKAGING water for this operation.Avoid smearing and feathering of the 10.1 fl,oz.Cartridges,24 Cartridges/Case l sealant to allow full performance of the cured seam.Excess 20 fl.oz.'Sausages,12 Sausages/Case sealant should be dry-wiped orjolnts should be properly taped. 5 Gallon Pails Cleaning: After dry-wiping uncured sealant from substrates 52 Galton Drums and tools,remaining uncured sealant can be removed by using Xylene,Toluene or similar aromatic solvents.Please refer to STORAGE,PACKAGING&SHELF LIFE the SDS'provided for these solvents before use.Bostik Hand Shelf life of Bostik 915 must be checked prior to using the Towel and Specialty Sealant Remover can also remove uncured product;do not use past its shelf life.Caulk past Its shelf life sealant: Cured sealant is usually very difficult to remove may not perform or adhere as described by.this data sheet. withoutaltering or damaging the surface to which the sealant High temperature and high relative humidity may reduce i has been misapplied.Cured sealant can be removed byabrasion significantly the shelf life of polyurethane sealants.If you are or other mechanical means(scrapers,putty knives), unsure of the expiration date of your Bostik product,please Curing Time: Bostik 915 is a moisture cure, Polyurethane call customer service at 1-800-7/BOSTIK(1-800-726-7845)to Sealant.On wood,with ambient air at 50%relative humidity check If the product is still within its shelf life. and at 73°F,polyurethane sealants will generally skin within four hours and cure 1/16 of an inch per day.Lower temperature COLORS and lower relative humiditywill significantly Increase the skin White Stone Bronze Tan 9 Y Black Limestone Md.Bronze Light Gray I time and cure time of a polyurethane sealant. Terra Cotta Aluminum Stone Painting and Coating:Bostik 915 Is not an RTV silicone and therefore is suitable for paintingwith latex-basedpalnts.Paint AVAILABILITY chemistries and flexibility characteristics of the paint films Available from authorized Bostlk distributors. Go to over the sealant may affect wetting,adhesion and integrity www.bostik-us.com.and check on our distributor locator of the paint layer,and It is therefore mandatory to pretest for the closest distributor in your location or call customer the paint or other coating over the Bostik 915 to ensure the service at1-800-7/BOSTIK(1-800-726-7845). j t I f • t I • •• • • . • • rA • i Width .�..._. F none quart of primer,coverage Is as follows, Depth 1%B'! 1/4" ' 3!B"' ;1�2" 578�r 3/4" 7/e •1'x G { �..,;, .� _.. .,�.,� ., 1 unit 5 gallon pail { 1/8" 99 49 33 24 20 16 14 12 5 units 1.5 gallon unit . /414 24 20 12 110 8 7 6 7 gallons 1 gallon unit i 11 8 I 6 5 5 4 65 4 3 3 'All values area pproximatlons and can vary due to joint dimension' y variations,porosity,and texture of substrates.Yield per cartridge I Linear Feet Per 10,1 FL,OZ.Cartridge is approximate due to variables beyond Bostik's control,such as Irregular Joint configuration and Installation technique. COVERAGE • • • • . •• r . 1.01:14 ftfi t i -Width �rty lVal lipropegTest Method%Note %� ,„. �� Tool/Work Time 60 min. Bostik Test Method Depthf2BB 3/ 7%B �___t Skin Time 4 Hours Bostik Test Method 1/B'' ' 145 95 71 58 48 40 36 Curing Time@77°F(25•C) 2-7 days Varie'sw/relative hu idit • 71 56 36 29 23 20 17 • •• 32 23 17 16 13 11 Flow,Sag or Slump 0.3 inch Bortik TQstJ�teth--W ••••;• 1 17 14 11 10 8 •values given above are not Intended to bepV4 jp•SQecificatI:rf•••• •• preparation purposes. • •••• • ••••.. Linear Feet Per 20 fl.oz.Sausage • �••••� COVERAGE FOR S GALLON(18.9 L)PAIL Width- ..-' � - _ �_� - ••••• i ,...._. Property. >Value! Test Method/Note - .........1,,...,..� Hardness(Shore A) 42 As1M Q2 40 • • � 1/8 ^t 6150 3100 2050 1540 1230 1025 870 770 • Modulus @ 100%Elongation 65 psi ASTM D 412 ;.r.;r •••••• 1540 1240 770 615 510 440 ' 370 @25%Etongation 45 psi *TM P%j2 • • i 680 510j 410 310 290 245 Tenslie Strength @Break 133 psi ASTM D 412 • : • • 370 1305 1245 1220 1185 • Elongation @ Break 685% ASTM D 412 I LlnearFeetPer 5Galion Pail Adhesion Peel >5piw TT-5-0023OC/ASTMC794 { Joint MovementCapability +/-35% TTS-00230C/ASTMC719 LIMITED WARRANTY UV Resistance Pass ASTM C793 The Limited Warranty for this product can be found at Static Uplift Resistance www.bostik-us.com/resource-center/warranties or by (concrete roof tile) 49 Miami-DadeTAS102 calling 1-800-726-7845 (choose option 2, then option 2 again). TO THE MAXIMUM EXTENT ALLOWED BY LAW, •Values given above are not Intended to be used In speclflcation BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED preparation purposes. WARRANTIES,INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED WARRANTY,THE SOLE REMEDY FOR BREACH OF WARRANTY IS REPLACEMENT OFTHEPRODUCT ORREFUND OFTHEBUYER'S PURCHASE PRICE. BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT,INCIDENTAL,CONSEQUENTIAL,OR SPECIAL DAMAGES TO THE MAXIMUM EXTENT ALLOWED BY LAW.DISCLAIMERS iNS1'IT ilk OF IMPLIED WARRANTIES MAY NOT BE APPLICABLE TO .. MEMBER® CERTAIN CLASSES OF BUYERS AND SOME STATES DO NOT BOSTIK HOTLI NE ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE ABOVE LIMITATIONS MAY Smart heLp NOT APPLY TO YOU. It Is the buyer's obligation to test the 1-800-726-7845 suitability of the product for an Intended use prior to using It. The Limited Warranty extends only to the original purchaser Bostik,Inc. and Is not transferable or assignable.Any claim for a defective 11320 W Watertown Plank Road product must befitedwithin 30days ofdiscovery ofaproblem, Wauwatosa,WI 53226 and must be submitted with written proof of purchase. www.bostik.com/us '' 06,02.16-This document supersedes all previously published literature. { fi MIAMI-DADS COUNTY MIAMI-DrAOE PRODUCT CONTROL SECTION 11805 SW 26 Street;Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC..RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADINlIN19TRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE IOF ACCEPTANCE (NOA) wiviv.mtamldade.ttov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable Miles'and regulations governing the use of construction materials. The documentation sub nitted.has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product ConQ'ol%gtioll �••• (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reser;%the tight to have this product or material tested for quality assurance purposes. If this product or material fails to,u(;F fgtjn in 48.6eedpted •• • manner, the manufacturer will incur the expense of such testing and the A14J may immed6tWP.Wvoke, mojlify, or suspend the use of such product or material within their jurisdiction. RER reserves the right tozavoke this�icccptance, ;••••; if it is determined by Miami-Dade County Product. Control Section that this product or nate iaf fails to%Q& the . • requirements of the applicable building code. 009000 •• ••• 0 0 0 0 0 0 0 0 .. 0000.. This product is approved as described h6•ein, and has been designed to comply with thj�. .lo��da Building Code including the High Velocity Hurricane Zone of the Florida Building Code. • 0000.. 000000 DESCRIPTION: VersaShield' Fire-Resistant Roof Deck Protection and VersaShiel.0*Solo-- Mi e-Mesistant Slip sheet LABELING:Each unitshall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RE,NtWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or.if there has been a revision or change in'the materials,use, and/or manufacture of.the product or process.Misuse of this NOA as all endorsement of any product, :. for sales,advertising or any other purposes sliall automatically terminate this NOA.Tailure to comply with any section of this NOA shall.be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded,by the words Miami-Dade County,Florida, and followed by the .._..-..__...__.._....p Y I Y g Y p 1 Y call be done - - ex u•atioti'date�tna 'be'dis ala ed-uradvertisin iiterah►re.- If an portion-of the-NOA-is dis ala ed then it sl in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user:by.the niallufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Ofticial. This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3. The submitted documentation was reviewed by Alex Tigera. E NOA No.: 16-1.216.02 MIAMI•DADECOUNTY Expiration Date: 02/07/22 Approval Date: 02/02/17 Page,1 of 3 i ROOFING ASSEMBLY APPROVAL °Category: Roofing Sub-Category: Underlaymcnt Material: Fiberglass SCOPE: This acceptance is for VersaShield Fire-Resistant Roof Dee](Protection (a.k.a "VersaShieldUndcrlaym6nt") and VersaShield®Solowl,Dire-Resistant Slip Sheet(a.k.a."VersaShield Solo"^t"),as described in this Notice of Accepthbce, for use Ni.ith approver/ prepared roof assemblies'. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. t PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Deseriptidir. •••••• • ...... ' VersaShield"Fire- 42"'x 100'rollsASTM D 226 Non-Asplial tic fiberglass-bagdd uftderla}jgVg 6 • Resistant Roof Deelc Type II and/or fire barrier. 000:00 0000000, • .6606. Protection •••• •• • • • •060 • 66 •6.6• VersaShield'Solo— 72"x 166.7' rolls UL790 tNon-Asphaltic fiberglass-1 a dslip sliegt anSVor j••• Fire-Resistant Slip Sheet 36,'x 166.7' rolls fire barrier. *0 6 090 :"••• 6 6,•6•. •6••6• • • • 6 • . . . 000000 MANUFACTURING LOCATION: •••••• • • • 6666•• 1. Conover;NC •• • *00 • • • 6 •6 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF-270-02-02 ASTM D 226 11/15/10 Technologies GAF-748'-02-01 ASTMD 226 12/12/16 ELK-063-02-01 TAS 100 09/27/01 Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 l ONK11990 UL790 05/18111 R19254 ASTM D 226 09/13/01 08CA37926 UL790 69/23/09 08CA49140 INSTALLATION: _..._....... __.._1 _..._. _. _ __ _ _ _ p. VersaShield Pue-Rcs�stant Roof Deck Protection of versaShi6ld�SoloT*rFiie-Resisfarit Sli�Sheet shall 6e T �- - –.___.._ installed in strict compliance With applicable Building Code. 2. VersaSkicld Fire-Resistant Roof Deck Protection or VersaShield SoloTI,+Fire-Resistant Slip Shect shrill be installed with a minimum 4-inch head lap in a shingle layer fashion. ! 3. VcrsaShields Fire-Resistant'Roof Deck Protection shall be'mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code_prescribed ASTM D 226 Type lI underlayment. NOA No.: 16-1216.02 MIAMMADECOUNTY Expiration Date: 02/07/22 Approval D te:.02/02/17 Page 2 of 3 1 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. !Minimum deck requirements shall be in. compliance with applicable building code. 3. VersaShield'Fire-Resistant Roof Deck Protection shall not be lett exposed as a.temporary roof for'longcr than 30 days of application.VersaShield'Solon*(Fire-Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield' Fire-Resistant Roof Deck Protection and VersaShield' SoloTM Fire-Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield' Fire-Resistant Roof.Deck Protection or VersaShield'Solo-Fire Resistant Slip Sheet may'be used. with any approved roof covering Notice of Acceptance listing.VersaShield Fite-Resistant Roof Deck Protection or VersaShield'Solo-1 Fire-Resistant Slip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield'Fire-Resistant Roof Deck Protection or VersaShield'Solon.,Fire-Resistant Slip Sheet is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade CoiWijX PV oduct Control Department for approval provided that appropriate documentation is provided to*taUt9thpatibility of the •••••• products,wind uplift resistance,and fire testing results. . 00 • • ••0• of 6. VersaShield' Fire-Resistant Roof Deck Protection and VersaShield'801OW Fir6-Resists U Sheet are.a noir • asphaltic underlaynient that may.be used as a fire barrier for prepared roof assemblies. IW fire classificagon of ;••••� , " specific roof assemblies using VersaShield' Fire-Resistant Roof Deck Protection or vorsaSl'neld SolW11*Fire. ..... . E Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire rating,*ef4l�s product. ..:..' 7. All products listed herein.shall have a quality assurance audit in accordance with the F1'oticlra'Buildh g Code and ••••;• Rule 61 G20-3 of the Florida Administrative Code. •:• LABELING: fee 0 •••: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo;c"and state of manufacturing facility,yellow line to identify the ASTM Standard designation or logo,aiid the following statement: "Miami-Dada County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. iAml-DADE COUNTYIE E BUILDING PERMIT BE QUIRE MENTS: Application for building permit shall be accompanied by copies of the following: r 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. - __. ......._ ___ END-OF THIS ACCEPTANCE--_. - NOA No.: 16-1216.02. MIAMI•DADECOUNTY Expiration Date: 02/07/22 Approval nate: 02/02/17 i Page 3 of 3' i