RF-17-2302 (2) 1 J _ - Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FIL 1 l Phone: (305)7954204 Fax: (305)756-8972 Inspection Number: INSP-295452 Permit Number: RF-9-17-2302 Scheduled Inspection Date: January 19, 2018 Permit Type: Roof Inspector: Naranjo, Ismael I Inspection Type: Final Roof Owner: Work Classification: Tile Job Address:672 NE 98 Street Miami Shores, FL 33138- Phone Number Parcel Number 1132060171780 Project: <NONE> Contractor: AFFORDABLE ROOFTEC, INC Phone: (954)962-9670 Building Department Comments NEW ROOF CONCRETE TILE WITH ICP FOAM Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments J Passed CREATED AS REINSPECTION FOR INSP-289492. 1/12/2018',I MISSING TILE UPLIFT TEST Failed (/ / Correction (� J Needed r Re-Inspection ❑ Fee i No Additional Inspections can be scheduled until re-inspection fee is paid. 1 , January 18,2018 For Inspections please call: (305)762-4949 Page 24 of 32 1 1 , • I Engineering & Testing Co. 7450 Griffin Road, Suite 140,Davie,FL33314 Phone:(954)581-7115,Fax:.(954)581-2415 www.cebb.net January 811, 2018 To: Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, FL 33138 Roof Tile Uplift Test Report Test Date: January 8, 2018 Permit#: RF-9-17-2302 Address: Carol Invest USA 672 NE 981 Street,Miami Shores,FL Contractor: Affordable Rooftec Roof Pitch: - 3:12; 7:12 Attachment method: Adhesive Pol set AH-160 Tile Type: Eagle Belair Roof Tile Device Used: "IMADA DPS 110" force gauge (Serial#340507) Total Sloped Roof Area: 5.80 squares All Testing is in strict accordance with the Florida Building Code, 2017 Edition, High Velocity Hurricane Zone — Testing Application Standard(TAS) 106. Roof Area: 5.80 squares Total Number of Tests Number of tests Passed %Passed Field Area(1): 2.80 squares 3 (T5-T7) 3 100% Perimeter Area(2): 3.00 squares 3 (T2-T4) 3 100% No.of Corner Areas(3): 1 1 T1) 1 100% Ridge/Hi Areas: 48 pcs Not Tested Not Tested 0 Based upon the field tests, I certify that 100% of the static up-lift tests "PASSED"the testing criteria of 35.0 lbf-load, and meets the attachment resistance for adhesive Set Systems, as specified in the NOA. The ridge tiles could not be tested due to the mortar finish on them. Should you ha'-ve_any questions regarding the above, or if require additional information, please do'not hesitate to contact this ofnce. Sincerely, CeBB Engineering& Testing Co. (NOA. 13- 919.02) 01/08/2018 Eduard iu,P.E.• Fla. Reg. o: 59997 For The Firm Cc: Affordable Rooftec Enc. Location Sketch -Calibration Certificate ce a 0 Engineering & Testing Co. 7450 Griffin Road, Suite 140,Davie,FL33314 Phone:(954)581-7115,Fax:(954)581-2415 www.cebb.net HANDLIFT RESULTS: Passed the protocol criteria of less than 3%loose. We performed the up-lift test. T—Tested tiles and Passed; Total Area: 5.80 squares No.of tested Tiles: F—Tested tiles and Failed; -Field Area(1): 2.80 squares -Field Area: 3 M—Missing Tiles; -Perimeter Area(2): 3.00 squares -Perimeter Area: 3 B—Broken Tiles; -No.of Corner area(3): 1 -Corner areas: 1 -Ridge/hip areas: 48 pcs =Ridge/Hip areas: 0 Sir: ..+7._ "f.r✓:..,r- 4/J___ /} rJ'd-r i F � TAS 106 TESTS LOCATION SKETCH k• Permit#RF-9-17-2302 Carol Invest USA 672 NE 98' Street, Miami Shores,FL Legend: 5-7,Field tests 2-4,Perimeter tests 1,Corner tests ce Doo Engineering & Testing Co. 7450 Griffin Road, Suite 140,Davie,FL33314 Phone:(954)581-7115, Fax:(954)581-2415 www.cebb.net TEST RESULTS (P=PASSED,F=FAILED Test Uplift Test Uplift Test Uplift Test Uplift Test Uplift Location Pull Location Pull Location Pull Location Pull Location Pull Test(P Test(P Test(P Test(P Test(P or F) or F) or F) or F) or 1 P 2 P 3 P 4 P 5 P 6 P 7 P je (Woo Engineering & Testing Co. 7450 Griffin Road, Suite 140,Davie,FL33314 Phone:(954)581-7115, Fax:(954)581-2415 www.cebb.net 4 °� � Qtall.ur cal, In ,, d.;11811 {ut}Tl�t1°I(tl(r Services a CEBB Corporation February 24,2017 P.O.No.Verbal QCM Job No. 17BM-139 CALIBRATION CERTIFICATE Imada-Force Gauge Range 0-110 Lbs. Accuracy f.5% a Indicated Scale Serial No.340507 Standard In Lbs_- Instrument Reads in Lbs. 0 0 10C 10.0 20 C 209 40 C 40.1 60 C 60,1 80 C 80.2 ' 100 C 100.2 -10 T -10.0 -20 T -19.9 40 T -39.9 -60 T -59.8 1 -80'1' -79.7 -100 T -99.7 Scale is within f.5%at Indicated Scale i t Calibrated with Instma Tensile tvtxhine,Lei Cell.SIN 936,QW 414,2 pisses,Range M000 Lb.'s. Acawwy at:0.0416.N.LS.T.4 Certs 4RP100420t1009.Date 9/1!)12015-9/10/20X Calibrated I.A.W.ANSUNCSL 7540-1 t The accuracy and calibration of this instrument are traceable to the National Institute of Standards&Technology and are guaranteed to meet published specifications. Date Calibrated 2124/2017 Date Due 2!2412018 Kevin Grate Q.C.Metallurgical,Ine. 23 ,.. it lzuad f i H"1� okvd 1:1. 1.99 (9;4)884-0089 :IiN€ '�,t.",62-57"',., C