Loading...
RF-16-3216 (2) AC132 -Engineering Inc. Testing & Engineering Services Roof Tile Uplift Test Report Certificate of Authorization #8131 Tel: 954-245-8976 Fax: 954-301-7776 -� 5230 NE 18T"Avenue Fort Lauderdale, FL 33334 Attention: Miami Shores Village, Building Division, 10050 NE 2nd Avenue, Miami Shores, FL 33138 Client: T&S Roofing Systems, Inc. Test Date:09/07/2017ermit# RF-11-16-3216 Property Address: 395 NE 92nd Street, Miami Shores, FL ,q Roof Pitch: Type of Tile: Roof Area: 5 in 12 Santafe Roof Tile 16.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160 Field Instrument : IMADA Force Gauge 0-100 Serial number:243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: (T1-T6) 6.00 sq. 6 As per FBC 2014 Passed Field Area: (T7-T16) 10.00 sq. 10 As per FBC 2014 Passed No.of Corner (T17-T35) 19 19 As per FBC 2014 Passed Ridge Areas: (T36-T44) 86 pcs. 9. As per FBC 2014 Passed Important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic.Therefore,this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordia y AC ering Inc. (NOA 09-1005.01) Anto io Acevedo, PE Fla. Reg. No: 36466 OA t0-4 1 a.Ot�- ..__ M2 Engineering Inc. Engineering and Laboratory Services 5230 NE 18'h Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 LL( . t f) rZ _Tj 37 T 2-1 Tho 4 3g 38 T 3� I? ; 4 716 - T7 Lf t 36 t " r