Loading...
MC-16-2905 Permit No. WIC-10-16-2905 `5�oaes i? Miami Shores Village t Permit Type:Mechanical-Commercial 10050 N.E.2nd Avenue NE ' Work Class 6cation:Addition/Alteration Miami Shores, FL 33138-0000 PerillPermit Status:APPROVED Phone: (305)795-2204 F�oriinA issue Date: 111212016 Expiration: 05/01/2017 Project Address Parcel Number Applicant 11300 NE 2 Avenue Number: Fine Arts Quad 1121360010160-06 BARRY UNIVERSITY INC Miami Shores, FL 33138-0000 Block: Lot: Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) Phone Cell Phone Valuation: $ 325,500.00 SOUTHEAST MECHANICAL CONTRA( (954)981-3600 Total Sq Feet: 17800 Tons:0 Available Inspections: Additional Info:HVAC SYSTEM WORKS AT FINE ARTS DEPA Inspection Type: Classification:Commercial Ventilation + Approved: In Review Final Comments: Date Approved: :In Review Rough Date Denied: Type of Work:HVAC SYSTEM WORKS AT FINE AR Rough Duct Scanning:3 Review Mechanical Duct Detector Test Review Mechanical a Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $195.60 Invoice# MC-10-16-61784 DBPR Fee $146.48 10/26/2016 Credit Card $50.00 $10,538.56 DCA Fee $146.48 Education Surcharge $65.20 11/02/2016 Check#:056001 $ 10,538.56 $0.00 t Permit Fee $9,765.00 Scanning Fee $9.00 Technology Fee $260.80 Total: $10,588.56 t In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that the foregoing infor tion is accurate d that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,I abk4c4ize the above- ac o the work stated. November 02, 2016 f Authorized Signature:Owner / Applicant / Contractor / Agent 15ate Building Department Copy November 02,2016 1 J Miami Shores Village Building Department 7BY `T `.r� i10050 N.E.2ndAvenue, Miami Shores, Florida 33138 OCT 2 5 201Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 : yY"4�`tr�+f"e� t*s•`Nr. �BV LO BOWING '- �yk,'.j `� ' ���y��hn�,� :,,t,;�;�,,��n� MasterPermit No.cc-12-15-301'3 PERMIT APPLICATION sub Permit lvo:MCI ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING Q MECHANICAL ❑PUBLIC WORKS [—] CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd fine arts quad, miami shores, FL 33161 City:_ 4 Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated:Yes ' NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: i FFE: OWNER: Name,(Fee Simple Titleholder):Bary University Phone#: - k Address:11300 NE 2nd Ave, Miami Shores, FL 33161 City: 1 State: Zip: Tenant/Lessee Name: Jeffrey Yao Phone#: Email:-Jyao@barry.edu CONTRACTOR:Company Name: southeast mechanical contractors Phone#: 954-981-3600 Address. 2120 sw 57 terrace city. pembroke park State: fl Zip: 33023 Qualifier Name: Robert Macklin Phone#: 954-605=4805 State Certification or Registeation#: CIVIC 1250173 Certificate of Competency#: 183-1180 DESIGNER:Architect/Engineer: Harvard Jolly Phone#: (561) 478-4457 AdIdress:2047 vista parkway yyCity: West palm beach State: fl . zip: 33411 Value of Work for this Permit:$ 4325,500 Square/Linear Footage of Work: 17,800 GS Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace El Demolition Description of work: HVAC system works at fine arts department wings (5 wings) including new fan coil units and outside air units Specify color of color thru tile: I Submittal Fee$ Permit Fee$ >t CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ I (Revisedp2/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address _ City State Zip Mortgage Lender's Name(if applicable) " Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. i Signature 111kiA Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this i day of O(m2016 by day of © r 20 ( rc by S" ----,who is personally known to ry1 aJc- (h wh personally known _MV or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: BEVERLY 3 NSbA �sr Public stau or Fadda a' _ rev Co Seal: JNoury effryJYeo Seal: EXPIRES:lure2018 Bonded Thru Notary public i�Unde wnteis s My Commflrsfon FF 188481 �;o��;�••'• end, ExDue�11/12/2018 ************************** ** * ******* ***** ************************************************************* APPROVED BY / Ons Examiner :,I►e;' Zoning Structural,Review Clerk ' (Revised02/24/2014) ,acoCERTIFICATE OF-LIABILITY INSURANCE DATEYYYY) L.� 10/26/20162016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the term's and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Angie Desormeaux Bowen, Miclette& Britt of Florida, LLC PHONE 407-647-1616 FAX ' .4O7-628-1635 1020 N. Orlando Avenue E-MAIL Certificates@bmbinc.com Suite#200 @ Maitland FL 32751 INSURE S AFFORDING COVERAGE NAIC# INSURERA:Zurich American Ins Co 16535 INSURED SOUTHEASTM4 INSURERB:American Guarantee and Liability In 26247 Southeast Mechanical Contractors, LLC INSURERC:North River Insurance Co. 21105 2120 57th Terrace INSURERD:Brid efield Casualty Insurance Com 10335 Hollywoodo FL 33023 , INSURERE:Allied World Assurance US Inc. 19489 -- INSURER F: COVERAGES CERTIFICATE NUMBER:234782208 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD - INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, 1 EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. 1�7R TYPE OF INSURANCE INSD WVD POLICY NUMBER POLICY M DDY/YYYY MMEFF OI//DDY� LIMITS A X COMMERCIAL GENERAL LIABILITY Y Y GL0008589701 1/1/2016 1/1/2017 EACH OCCURRENCE $1,000,000 CLAIMS-MADE X�OCCUR DAMAGE T RENTED c PREMISES Ea occurrence $300,000' MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY PRO- JECTF—] LOC PRODUCTS-COMP/OPAGG $2,000,000 OTHER: $ B AUTOMOBILE LIABILITY Y Y BAP008589501 1/1/2016 1/1/2017RaTUWT $ Ea accident 1,000,000 IxANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ HIRED AUTOS X NON-OWNED PR PERTY DAMAGE $ AUTOS Per accident C X UMBRELLA LIAB X OCCUR Y Y 5811062787. 1/1/2016 1/1/2017 EACH OCCURRENCE $10,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $20,000,000 DED X I RETENTION$0 I $ D WORKERS COMPENSATION Y 019606994 1/1/2016 1/1/2017X PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE I ER ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 E Pollution Y 03093654 1/1/2016 1/1/2017 Per Occurrence 1,000,000 Aggregate 2,000,000 i r DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) ' The following policy provisions and/or endorsements form part of the policies of insurance represented by this certificate of insurance. The terms contained in the policies and/or endorsements supersede the representations made herein. Electronic copies of the policy provisions and/or endorsements listed b 1 elow are available by emailing: certificatesQbmbinc.com . When required by-written contract, those parties listed in said contract, including the certificate . See Attached. . . 1 CERTIFICATE HOLDER CANCELLATION I SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE/CANCELLED BEFORE MIAMI SHORES VILLAGE BLDG DEPT THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 NE 2ND AVE ACCORDANCE WITH THE POLICY PROVISIONS. MIAMI SHORES FL 33138 AUTHORIZED REPRESENTATIVE ' ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD a I I AGENCY CUSTOMER ID: SOUTHEASTM4 LOC#: i AC RE® ADDITIONAL REMARKS SCHEDULE Page 1 of 1 AGENCY NAMED INSURED Bowen, Miclette & Britt of Florida, LLC Southeast Mechanical Contractors, LLC 2120 SW 57th Terrace POUCY NUMBER Hollywood FL 33023 CARRIER NAIC CODE I EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: 25 FORM TITLE: CERTIFICATE OF LIABILITY INSURANCE holder, are added as an additional insured with respect to the general liability, including products and completed operations, auto liability, pollution liability and umbrella liability as afforded by the policy and/or endorsements. When required by written contract, waiver of subrogation, with respect to the general liability, auto liability, worker's compensation, and umbrella, is granted to those parties listed in said contract, including the certificate holder. The general liability, auto liability, and umbrella liability certified herein are primary and non-contributory to other insurance available, but only to the extent required by written contract. RE: MECHANICAL CONTRACTOR JOB: Barry University Fine Arts Quadrangle Improvements 11300 NE 2nd Ave. , Miami Shores, FL 33161 t I f y '1 ACORD 101 (2008/01) ©2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD a BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895—954-831-4000 -VALID OCTOBER 1,2016 THROUGH SEPTEMBER 30,2017 - DBA: Receipt#:PAINTING/SEALCOAT/CONTRACTO Business Name: SOUTHEAST MECHANICAL CONTRACTORS Business Type: (MECHANICAL CONTR) Owner Name:WILLIAM L CATRON Business Opened:07/02/2002 Business Location:2120 SW 57 TER State/County/Cert/Reg:CMC008221 02CU185 WEST PARK Exemption Code: I! Business Phone: Rooms Seats Employees Machines Professionals 30 For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years I Collection Cost Total Paid 81.00 0.00 0.00 1 '0.00 1 0.00 0.00 81.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS 1 THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non-tegulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: WILLIAM L CATRON Receipt #1CP-15-00018683 2120 SW 57 TER Paid 08/11/2016 81.00 WEST PARK, FL 33023 I 2016 . 2017 ` STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION 850 487f-1395 . � CONSTRUCTIONLICENSING BOARD ( � • py tom' 1940 NORTH MONROE STREET- TALLAHASSEE FL 32399-0783 , MACKLIN, ROBERT SOUTHEAST MECHANICAL CONTRACTORS ,. 2120 SW 57 TERRACE HOLLYWOOD FL 33023 xi Lone ratulations! With this license you become one of the nearlymillion Floridians licensed by the Department of Business and s sSTATE OF FLORIDA , Professional Regulation. Our professionals and businesses range DEPARTMENT OF BUSINESS AND --. from architects to yacht brokers,from boxers to barbequePROFESSIONAL�REGULATION' restaurants,and they keep Florida's economy strong. •H''' IS UED 06/262016 _ CMC1250173 _. _ Every day we work to improve the way we do business in order /"' _ _ .,_,...-.�,.�•...�,•--•- r to serve you better. For information about our services,please -. log onto www.myfloridalicense.com. There you can find more -;,CERTIFIED MEGWANi AL GOND TURA.cTOR _ i information about our divisions and the regulations that impact -MACK.LIN;ROBERT " �� �t --- ` you,subscribe to department newsletters and learn more about SOUTHEAST MECHANICAL GONTRACMTORS_--_ the Department's initiatives. Our mission at the Department is:License Efficiently,Regulate - ti- ---`---_ Fairly.We constantly strive to serve you better so that you can IS�CERTIFIED under_ � the.provii:siZns•of Ch-489 Fs. serve your customers. Thank you for doing business in Florida, --ExplralionUG date:,A31 2018''~ �, �„t`lZ��13�8'"""^ and congratulations on your new license! I DETACH HERE KEN LAWSON,SECRETARY 1 RICK SCOTT,GOVERNOR _ --- - STATE OF FLORIDA —D PARTMENT OF-BUSINES" D PROFESSIONAL REGULATION~ yq , ^CONSTRUCTION'INDUSTRY•LICENSING BOARD, 1 �s*•'' �...-..-«.»..,.,,w-moo__ -_ .-*_., "_-___ - -:`. -Y'ti., �'`'�c'. �.'1 ti..'�... The MECHANICAL CONTRACTOR-- Named.`below.IS'CERTIFIED--` `�- .;,�., �ti;�. '� I ` �O6"R + Under';the.provisions°of,Chapter 489 FS--,-�,' Ezp ratio`n,date:AUG 31 720'18-= � j 2H120,S � PiL';tO '" TORS R–SNTRACSOUTHASTMECHANIC &51.TERRACE OYNOL3023" ISSUED: o_ w. . , 06/26/2016 DISPLAY AS REQUIRED BY LAW sEQ# 1-1606260001318 ni Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 C C i S_ 3(p Inspection Number: INSP-279559 Permit Number: MC-10-16-2905 Scheduled Inspection Date: March 29, 2017 Permit Type: Mechanical - Commercial Inspector: Perez,JanPierre Inspection Type: Final Owner: , BARRY UNIVERSITY Work Classification: Addition/Alteration Job Address:11300 NE 2 Avenue Fine Arts Quad Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360000050-06 Project: BARRY UNIVERSITY 4 Contractor: SOUTHEAST MECHANICAL CONTRACTORS Phone:F(954)981-3600 Building Department Comments HVAC SYSTEM WORKS AT FINE ARTS DEPARTMENT ISPEC Passed Comments INNSPEC WINGS 5 WINGS INCLUDING NEW FAN COIL UNITS TOR COMMENTS False AND OUTSIDE AIR UNITS 3 7 Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-269778. need T&B report �. 954736-0036 ricardo cinti Failed i Correction Needed Re-inspection ❑ Fee I No Additional Inspections can be scheduled until re-inspection fee is paid. , March 28,2017 For Inspections please call: (305)762-4949 Page 24 of 36 9 Air Logic CERTIFIED TEST, ADJUST, AND BALANCE REPORT MARCH 14,2017 PROJECT: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS a 1130 NE 2ND AVENUE F MIAMI, FLORIDA 33161 CONSULTING ENGINEER: OCI ASSOCIATES,INC. 2 HARVARD CIRCLE,SUITE#100 WEST PALM BEACH, FLORIDA 33409 4 HVAC CONTRACTOR: ' SOUTHEAST MECHANICAL CONTRACTORS 2120 SW 57TH TERRACE HOLLYWOOD, FLORIDA 33023 NEBB TAB FIRM: AIR LOGIC 8973 SW 212 LANE CUTLER BAY, FLORIDA 33189 CERTIFICATION#3443 Page 2 of 22 t Air Logic +fIfE. PROJECT: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS 1130 NE 2ND AVENUE MIAMI, FLORIDA 33161 THE DATA REPRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING,ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES,WHICH EXCEED NEBB TOLERANCES,ARE NOTED IN THE TEST-ADJUST-BALANCE REPORT PROJECT SUMMARY. SUBMITTED AND CERTIFIED BY: AIR LOGIC CERTIFICATION#: 3443 CERTIFICATION EXPIRATION DATE: MARCH 31, 2017 ServJC� i ROI NN A.BLANK CUMMICAtTION 3443 Exp.3/31/17 rornc MARCH 14,2017 , ` ✓ DATE ROBIN BLANK Page 3 of 22 Air Logic TABLE OF CONTENTS Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 SECTION DESCRIPTION PAGES I COVER PAGE 1 I PROJECT INFORMATION 2 I NEBB CERTIFICATION 3 TABLE OF CONTENTS 4 I COVER LETTER 5 II FAN COIL UNITS 6- 18 III EXHAUST FANS 19-20 IV INSTRUMENT CALIBRATION FORM 21-22 t r Page 4 of 22 ' AirLo�ic 8973 SW 212 LANE CUTLER BAY, FLORIDA 33189, PHONE:(305)971 -9672 OFFICE@AIRLOGICSERVICES.COM FAX:(305)971 -6649 Southeast Mechanical Contractors 2120 SW 57th Terrace Hollywood, Florida 33023 Attention: Mr. Riccardo Cinti Subject: HVAC Test and Balance Reference: Barry Univeristy Fine Arts Quadrangle Improvements 1130 NE 2nd Avenue Miami, Florida 33161 Mr. Cinti, On Friday, March 10, 2017,we completed our test and balance procedures for the HVAC system installed and operating at the above referenced project.The following general comments and field data are for your information and affirmative action: GENERAL COMMENTS: 1 Total air quantities were determined by pitot tube traverse of the main supply, return, exhaust,and outside air ducts where available. 2 Individual airflow quantities measured by digital flowhood manufactured by Alnor. If we can be of further assistance, please contact us at your convenience. MARCH 14, 2017 DATE ROBIN BLANK Page 5 of 22 t r Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 r 1 , FAN COIL UNITS f t } Page 6 of 22 Air Logic Project: BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit # 1 Location:. FA135 Office, FA Chair Ceiling Serves: FA134, FA135, FA136, FA137 Unit Make Trane Unit,Type Horizontal Draw Thru Model BCHD024B2JOA4NO2Z20 Fan,(Qty)Type_ (1) Forward Curve Serial T161(39525 Filter(Qty)Size Air Guard (1) 16 x 25 x 2 _ Description: _ Design: Actual: Calculation/Factors Notes: Fan RPM1463 Direct Drive Low Speed Motor Size _ 1/2 1/2 Volts/Phase/Cycle 208/1/60 201 Amps 4.3 .9 CFM 900 850 94% OA CFM NA 9 35 Pre-Filter Static: - .08" Pre-Coil Static: - .19" Fan Suction Static: - .65" Discharge.Static: - .22" External Static .5" .3" Total Static 1.7" .87" Coil APD 1.01" .45" OA Temperature 91/79 76/68 Mixed Air Temp 76/63 71/61.3 Leaving Air Tern p 51.86/51.62 55.5/51 Total BTUH 29,390 24,770 t Readings By:Anthony Williams Date:02/20/2017 Page 7 of 22 _ Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS = Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 FCU - 1 Air Distribution Schedule Area Served: Size: Design CFM: Actual'CFM: % Notes: SUPPLY FA134 Workroom 7 x 7 130 125 96% FA135 Office 9 x 5 165 180 109% FA135 Office 9 x 5 165 175 106% FA136 Office 61'0 100 100 100% FA137 Office 10116 300 270 90% r TOTAL: 860 850 99 RETURN FA134 Workroom 7 x 7 130 120 92% FA135 Office 7 x 9 335 325 97% FA136 Office 6110 100 100 100% FA137 Office 10"0 300 270 90% TOTAL: 865 815 94% i Readings By:Anthony Williams Date:02/20/2017 Page 8 of 22 Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit #r 2 Location: Ceiling of FA133B Office Serves: FA133A, 1338, 133C,133D, 133E, 133D, 133E, 133F & FA132 3. Unit Make Trane Unit Type Horizontal Draw Thru Model BCH D05462JOA4M02Z2050 Fan(Qty)Type (1) Forward Curve Serial T16K39526 Filter,(Qty)Size (2)20 x 20 x 2 Description: Design: Actual: Calculation/Factors Notes: Fan RPM 1463 Direct Drive Low Speed Motor Make/Size Trane/1/2 Trane/1/2 Volts/Phase/Cycle 208/1/60 203 Amps 4.3 1.2 CFM 1,420 1,390 98% OA CFM NA 100 Pre-Filter Static: - .08" Pre-Coil Static: - .12" Fan Suction Statie: - .33" Discharge Static: - .12" External Static .5" .2" Total Static 1" .45" Coil APD. .34" .11" OA Temperature 91/79 76/68 AMixed Air Temp 76/63 70.3/57.7 Leaving Air Temp 54.3/53.85 51.5/49.6 Total BTUH 38,050 30,200 Readings By:Anthony Williams Date:02/20/2017,3/10/2017 Page 9 of 22 Air Log C Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 FCU - 2 Air Distribution,Schedule Area Served: Size: Design CFM: Actual CFM: % Notes: SUPPLY FA 132 Adjunct 7 x 7 90 100 111% FA133 Corridor 7 x 7 90 95 106% FA133 Corridor 7 x 7 80 75 94% FA133A Office 7 x 7 130 125 96% FA133B Office 10110225 205 91/ FA133C Office 11 x 9 225 225 100% FA133D Office 11 x 9 225 225 100% FA 133E Office 11 x 9 225 210 93% FA 133F Office 7 x 7 130 130 100% TOTAL: 1420 1390 98% RETURN FA132 Adjunct 8 x 8 130 115 88% FA133 Corridor 8 x 8 130 115 88% FA133A Office 8 x 8 100 95 95% E FA133B Office 12 x 10 225 215 96% FA133C Office 12 x 10 225 215 96% , FA133D Office 12 x 10 225 220 98% FA133E Office 12 x 10 225 200 89% FA133F Office 8 x 8 130 120 92% ' TOTAL: 1390 1295 93% t 4 Readings By:Anthony Williams Date:02/20/2017,3/10/2017 Page 10 of 22 + f Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit # 5 Location: Ceiling of FA128 Office Serves: FA130 Classroom, FA128 Office Unit Make,_ Trane Unit Type Horizontal Draw Thru Model BCH D054132J0A4M04Z2040 Fan(Qty)Type._ (1) Forward Curve Serial T161(39527 Filter(Qty)Size (2) 20 x 20 x 2 Description: Design: Aetual: Calculation/Factors Nofes: Fan RPM 917 Direct Drive Medium Speed Motor Make/Size Trane/1 Trane/1 Volts/Phase/Cycle 208/1/60 203 Amps 7.7 3.4 CFM 1,660 1,580 95% Pre-Filter Static: - 09" Pre-Coil Static: - .15" Fan Suction Static: - .57" Discharge Static: - .22" External Static .5" .31" Total Static 1.2" .79" Coil APD NA .42" Return Air Temp- 76/63 68.9/62.4 Leaving Air Temp 55.1/54.4 52.1/49.8 Total BTUH 461430 56,780 Readings By:Anthony Williams Date:02/20/2017 Page 11 of 22 Air logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE;FLORIDA 33161 FCU - 5 Air Distribution Schedule Area Served: Size: Design CFM: Actual CFM: % Note's: SUPPLY FA128 Office 8 x 8 100 105 105% 1 FA129 Office 8 x 8 100 90 90% FA130 Classroom 14 x 10 365 355 97% 1 FA130 Classroom 14 x 10 365 360 99% ' FA130 Classroom 14 x 10 365 335 92% FA130 Classroom 14 x 10 365 335 92% TOTAL: 1660 1580 95% RETURN FA128 Office 7 x 7 150 100 67% FA129 Office 7 x 7 150 100 67% FA130 Classroom 23 x 23 1 1450 1 1380 95% TOTAL: 1750 1580 90% i I { E Readings By:Anthony Williams Date:02/20/2017 Page 12 of 22 Air Logic Project: BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit # 13 Location: , FA138 Ceiling t Serves: FA138, FA139, FA138A& FA138B Unit Make Trane Uniffype I Horizontal Draw Thru Model 13CHD036I32J0A4M04Z103 Fan (Qty)Type (1) Forward Curve Serial T16K39529 Filter,(Qty)Size (2) 16 x 20 x 2 Description: Design: Actual: -Calculation/Factors Notes: - Fan RPM, 1323 Direct Drive Medium Speed Motor Make/Size Trane 1 Trane 1 Volts/Phase/Cycle 208/1/60 206 Amps 7.7 3.1 CFM 1,200 1,255 105% OA CFM NA 145 Pre-Filter Static: - .07" Pre-Coil Static: - .17" Fan Suction Static: - .61" Discharge Static: - 11" External Static .25" .36" Total Static 1.09" .72" Coil'APD .58" .44" OA Temperature 91/79 68.2/65.1 Mixed Air Temp _ 76/63 69.8/61.5 Leaving Air Temp 56.4/55.5 57.3/54.6 Total BTUH 321210 25,360 Readings By:Anthony Williams Date:02/24/2017,3/10/2017 Page 13 of 22 ' Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 i FCU - 13 Air Distribution Schedule Area Served: Size: Design CFM: Actual CFM: % Notes: SUPPLY FA138B Men's Dressing 13 x 9 400 415 104% FA138A Women's Dressing 13 x 9 400 400 100% FA138 Green Room 7 x 7 100 110 110% FA139 Costume Studio 11 x 5 300 330 110% TOTAL: 1200 1255 105% RETURN , FA138D Men's Dressing 15 x 9 400 380 95% FA138C Women's Dressing 15 x 9 400 365 91% FA138 Green Room 9 x 7 100 95 95% FA139 Costume Studio 11 x 9 300 270 90% TOTAL: 1200 1110 93% I r Readings By:Anthony Williams Date:02/24/2017,3/10/2017 Page 14 of 22 i Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS. Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit # 14 Location: Ceiling/Corridor FA140 Serves: FA140, FA141, FA142, FA143, FA144, FA145,,FA148 Unit Mike Trane Unit Type Horizontal Draw Thru Model BCH D054F2JOA4N 04Z1025AC Fan(Qty)Type (1) Forward Curve Serial T16K39530 Filter(Qty)Size (2) 20 x 20 x 2 Description: Design: Actual: Calculation]Factors Notes: Fan RPM 935 Direct Drive Medium Speed Motor-Make]Size Trane/1 Trane/1 Volts/Phase/Cycle 208/1/60 200 ' Amps 4.8 1.5 CFM 1,360 1,425 105 OA CFM NA 285 Pre-Filter Static: - .24" Pre-Coil Static: - .34" Fan Suction Static: - .75" Discharge Static: - .13" External Static .5" .37" Total Static 1.31" .88" `Coil APD .61" .41" OA Temperature 91/79 76/68 Mixed Air Temp 76/63 67.6/62.6 Leaving Air Temp 52.6/52.5 53.8/50.3 Total BTUH 48,450 50,410 Readings By:Anthony Williams Date:02/20/2017 Page 15 of 22 i i Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS k Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 FCU - 14 Air Distribution Schedule Area,Served: Siie: - Design CFM: - Actual CFM: % Notes: SUPPLY FA140 C6rridor 6110 100 105 105% FA140 Corridor 6110 100 105 105% FA141 Practice 8110 200 220 110% FA142 Practice 8110 200 210 105% FA143 Practice 8110 200 200 100% FA144 Practice 6110 100 95 95% FA145 Practice 6110 100 100 100% FA146 Practice 6110 100 110 110% FA147 Practice 6110 -100 110 110% FA148 Practice 6110 100 105 105% FA149A Storage 6110 60 65 108% TOTAL: 1360 1425 105 RETURN FA141 Practice 8110 200 190 95% FA142 Practice 8110 200 215 108% FA143 Practice 8110 200 205 103% FA144 Practice 61TO 100 110 110% FA145 Practice 6110 100 110 110% FA146 Practice 6110 100 110 110% FA147 Practice 6110 100 100 100% FA148 Practice 6110 100 100 100% TOTAL: 1100 1140 1 104% a r Readings By:Anthony Williams Date:02/20/2017 Page'.16 of 22 Air Logic Project: I BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 1 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit # 15 Location: Ceiling of FA149 Music Studio Serves: FA149 Music Studio Unit Make Trane Unif Type? Horizontal Draw Thru g Model BCH D054F2JOA4N0271025 Fan(Qty)Type (1) Forward Curve Serial T16K39531 Filter,(Qty)Size (2) 20 x 20 x 2 Description: -besignc Actual: Calculation/Factors Notes: Fan RPM 906 Direct Drive Medium Speed Motor Make/Size Trane/1/2 Trane/1/2 Volts/Phase/Cycle 208/1/60 202 _ Amps 2.6 1.5 CFM 1,500 1,600 - 107% OA CFM NA 120 Pre-Filter Static: - .04" Pre-Coil Static: - 1" Fan Suction Static: - .58" Discharge,Static: - .47" External Static .5" .51" Total Static 1.23" 1.05" YCoil APD .55" .48" OA Temperature 91/79 76/68 Mixed Air Temp 76/63 68.4/62.1 Leaving Air Temp - 52.5/52.4 55.8/52.8 Total BTUH 45,900 43,400 t Readings By:Anthony Williams Date:02/20/2017 Page 17 of 22 Air L is r Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Fan Coil Unit (OAU # 1) Location: Ceiling of FA129 Office Serves: FA129, FA130 Classroom, FA128 Office Unit Make Trane Unit Type Horizontal Draw Thru Model BCHD02462JOA4NO2Z Fan (Qty)Type (1) Forward Curve - _ Serial T161(39528 Filter(Qty)Size (1) 16 x 25 x 2 Description: Design: Actual: Calculation/Factors Notes: Fan RPM 1170 Direct Drive Medium Speed Motor Make,/Size Trane/1/2 Trane/1/2 Volts/Phase/Cy_cle 208/1/60 203 Amps 4.3 2.3 CFM 650 695 107 OA CFM NA 395 Pre-Filter Static: - .06" Pre-Coil Static: - .12" Fan Suction Static: - .49" Discharge Static: - .08" External Static .25" .14" Total Static 1.04" .57" Coil APD .34" .37" OA Temperature 91/79 76/68 _ Leaving Air Temp 55.08/54.98 54.8/51.6 Total BTUH 58,800 39,630 67% r OAU - 1 Air Distribution Schedule Area Served: Size: Design CFM: Actual CFM: % Notes: FA128 Office 8 x 8 100 110 110% FA129 Office 8 x 8 100 105 105% FA130 Classroom 18 x 12 450 480 107% TOTAL: 650 695 107% k k Readings By:Anthony Williams Date:02/20/2017 Page 18 of 22 Air Logic Project: BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 EXHAUST FANS S Page 19 of 22 { Air Logic Project: BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 Exhaust Fan # 7 Make Loren Cook Location A138D Men's Toilet Model Gemini 120 Series Type Ceiling Fan Serial NA Area Served Men's Toilet r Description: Design: Actual: Calculation/Factors: Notes: Fan RPM Direct Drive Direct Drive Low Speed Motor Make/Watts Queace/5 Queace/5 Volts/Phase/Cycle 115/1/60 117 Amps .19 .2 `CFM T NA 110 Static NA .02" Exhaust.Fan # 8 T Make Loren Cook Location FA138C Women's Toilet Model Gemini 120 Series Type Ceiling Fan Serial NA Area Served Women's Toilet Description: Design: Actual: Calculation/Factors: Notes: Fan RPM Direct Drive Direct Drive Low Speed Motor Make/Watts Queace/5 Queace/5 Volts/Phase,/,Cycle 115/1/60 117 Amps .19 .2 CFM NA 110 Static NA .02" i Readings By:Anthony Williams Date:02/21/2017 Page 20 of 22 Air Logic Project: BARRY UNIVERSITY-FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161 i INSTRUMENT CALIBRATION FORM Page 21 of 22 Air Logic Project: BARRY UNIVERSITY- FINE ARTS QUADRANGLE IMPROVEMENTS Address: 11300 NE 2ND AVENUE, MIAMI SHORE, FLORIDA 33161, 2017 Instrument Calibration Form Description: Model Number: Serial Number: Cal. Date: Due Date: Dwyer.25" Differential Gauge DW33501 NA NR NR Dwyer.50" Differential Gauge DW33502 NA NR NR Dwyer 3.0" Differential Gauge DW33505 NA NR NR Dwyer Pitot Tube- 18 Inch DW33103 NA NR NR Dwyer Pitot Tube-48 Inch DW33106 NA NR NR Dwyer Pitot Tube-36 Inch DW33105 NA NR NR Dwyer Pitot Tube- 12 Inch DW33109 NA NR NR Alnor Hydronic Manometer HM670 71222048 12/28/2016 12/18/2017 Alnor, Inc. Capture Hood EBT721 9117063 1/19/2017 1/19/2018 Alnor Rotating Vane Anemometer RVA801 A03744 5/11/2016 5/11/2017 Precision Hygro Thermometer DT-3321 8103861 7/13/2016 7/13/2017 Fluke Electronic AC/DC Clamp Meter 324 26310196WS 8/18/2016 8/18/2017 Alnor Hydronic Temperature Probe 801291 71540007 9/23/2016 9/23/2017 Alnor Micromanometer 5825 T58251504008 4/22/2016 4/22/2017 Hoto Digital Stroboscope ESL-100 111082 8/30/2016 8/30/2017 Cole-Parmer Contact Probe Type K(5111) 34340033WS 2/4/2017 2/4/2018 United McGill Duct Pressure Blower NA 5892-5 NR NR NOTES: 1 NA- Not Applicable. 2 NR-Not Required. 1 r Page 22 of 22