Loading...
RF-16-3322Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 5 NE 105 Street Miami Shores, FL 33138-2030 Owner Information Parcel Number 1121360060090 Block: Lot: VIftaAaAMIMMOIMAKft GROUP 10 CAPITAL MANAGEMENT, Address 1680 MICHIGAN AVE Avenue MIAMI BEACH FL 33139 - Contractor(s) Phone CeII Phone CHERRY ROOFING ENTERPRISES !NI (954)963-2741 (954)658-9878 Roof Work Classification: Tile Permit Status: APPROVE[, Expiration: 06117/2017 Applicant GROUP 10 CAPITAL MANAGEMI Cell Valuation: Total Sq Feet: Type of Work: Re Roof Additional Info: RE ROOF TILE Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $8.40 $4.50 $4.50 $2.80 $300.00 $9.00 $11.20 $340.40 Pay Date Pay Type Invoice # RF -12-16-62295 12/08/2016 Check #: 1440 12/19/2016 Check #: 1441 Amt Paid Amt Due $ 50.00 $ 290.40 $ 290.40 $ 0.00 $ 13,500.00 3000 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work •. e by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PL BING, MECHANIC , r INDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I construction and zoning t all the fo -going information is accurate and that all work will be done in compliance with all applicable laws regulating e, I auth• ize the above-named contractor to do the work stated. December 19, 2016 Autho Signature: Owner " / Applicant / Contractor / Agent Building Department Copy Date December 19, 2016 1 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO/"r '1z_/C ji� TAX FOLIO NO.I1'' 13�'-o= cac:, STATE OF FLORIDA: R . 1 - 1ZS COUNTY OF MIAMI-DADE: STATE OF THE UNDERSIGNED hereby gives notice that improvements will be made to 4• property, and in accordance with Chapter 713, Florida Statutes, the following i is provided in this Notice of Commencement. 1. Legal description of property and street/address: 3 Al / DS ST ao rvx%tti S n -M/ .ssi<orzis e,7- ? /3/f( 2.0 2. 2. Description of improvement: n?/Zcv%° 11111111111111111111111111111111111111111 l l l k C F7t4 201.680727401 OR. BK 30351 Ps 1241 (1Pas) RECORDED 12/19/2016 13:56:41 H(RVE Y RUVIH r CLERK OF COURT MIAMI-•DADE COUJNTY, FLORIDA that the my and OWN EOPPP HARVEY RUVI CL.. •• 1 . ' Is �.�� DC PPANFAIPS cp ace above reserved fQuse of recording office /41;„ ; .jY Y l N ER #111c., 3. Owner(s) name and address: S'4 -s7 /0.5-$r 51/6w5 - Interest in property: A5.1 S,.aAL %L Name and address of fee simple titleholder: 4. Contractor's name, address and phone number: CNE/V goo:''r.:c- 95-1 9 .Z7Y/ 39a/ S yo rev tJe.sT ?egg"- ,/ 33013 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Owner(s) or Owner(s)' Authorazficer/Director/Partner/Manager Prepared By Print Name 2,4/7 . 0(e/!gU v Print Name Title/Office Title/Office STATE OF FLORIDA COUNTY OF MIAMI-DADE The foregoing instrument was acknowledged before me this 2— day of By ,S,4i''I Sof i e r20 ❑ Individually, or ❑ as for U Personally known, or ❑ produced the following type of identification: Signature of Notary Public: Print Name: Prepared By \\�\\\1NIII TF1/ T4�/����i :;o�M�ssio F 9 V bat. 0'u' (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. Signature(s) of Owner(s # ' T� 9,9` ;'ia Babded fi :N9 / i o/./!1 (111 11�\`` Z 0 L 6 •ller(s)'s Authorized Officer/Director/Partner/Manager who signed above: By By 123_01-52 PAGE 3 9/12 Reileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123` Avenue Miami, Florida 33175-1174 Tel : 305-823-8008 / 305-397-6414 Fax: 305-823-3300 / 305-884-8834 Website: www.reilehengineering.com R C 16-i256 /2,--/:-/2 -4' -.?,.102 February 24, 2017 Cherry Roofing Enterprises 3901 Southwest 40 Avenue Hollywood, Florida 33023-6223 Project: Dear Sirs; ROOF TILE UPLIFT TEST REPORT Residential Home 5 Northeast 105 Street Miami Shores, Florida Information provided by client: Permit Number: Not Provided Date Completion: February 22, 2017 Roofing Contractor: Cherry Roofing Enterprises Project Number: 17-0202 (Testing Laboratory Certificate ii 1 ? -0715.04) In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground surface. The type of tile used for this project was reported to be concrete/clay Roof Tile. This tile was reported to have been foamed in place. At the time of our inspection, the entire area of the roof was examined for loose tiles. Not less than one (1) tile in ten (10) of all components in the field area and one (1) tile in five (5) of all tiles in the perimeter and comer areas were physically examined. A minimum of one (1) test per every two (2) squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer areas were conducted. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above-mentioned protocol. Attached please find a copy of our test report for your review. Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation /2 *videtf ohamad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT TEST Residential Home 5 Northeast 105 Street Miami Shores, Florida Cover Page Page 2 thru 6 of 6 Drawing 17-0202 Reileh Engineering Corporation -- Project Number - 17-0202 — Page 2 of 6 Report of TILE UPLIFT TEST for Residential Home 5 Northeast 105 Street Miami Shores, Florida Project Number: 17-0202 1 Test Load (1 35 est Stahl` Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass 9 35 Pass 10 35 Pass 11 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass Reileh Engineering Corporation -- Project Number - 17-0202 — Page 3 of 6 .fiw f wi Test Number " ; g ' Test Load (lb!) Test Status 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass 37 35 Pass 38 35 Pass 39 35 Pass 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 52 35 Pass 53 35 Pass 54 35 Pass Reileh Engineering Corporation -- Project Number - 17-0202 — Page 4 of 6 est Numbe Test Load (Ib!) est Status 55 35 Pass 56 35 Pass 57 35 Pass 58 35 Pass 59 35 Pass 60 35 Pass 61 35 Pass 62 35 Pass 63 35 Pass 64 35 Pass 65 35 Pass 66 35 Pass 67 35 Pass 68 35 Pass 69 35 Pass 70 35 Pass 71 35 Pass 72 35 Pass 73 35 Pass 74 35 Pass 75 35 Pass 76 35 Pass 77 35 Pass 78 35 Pass 79 35 Pass 80 35 Pass 81 35 Pass 82 35 Pass 83 35 Pass 84 35 Pass Reileh Engineering Corporation -- Project Number - 17-0202 — Page 5 of 6 Test Number Test Load (lbf) Test Status 85 35 Pass 86 35 Pass 87 35 Pass 88 35 Pass Test 1-18 Corner, 19-35 Ridge Caps, 36-50 Perimeter, 51-88 Field Reileh Engineering Corporation -- Project Number - 17-0202 — Page 6 of 6 15 14 44 12 11 NOPTH Q 80 79 15 46 78 45 47 84 77 16 42 17 49 99 85 O 10 9 75 74 41 8 7 62 50 88 87 le 86 95 58 51 52 0 70 11 0 69 59 z, 5457 72 O 65 64 56 620 0 55 61 60 68 2 57 56 65 0 67 38 66 3 59 b ' r 58' NUMI OF 11 5T pFr;IMmr - 1200 5P 00126E CAP 15T LOCATION FELr7 - 38 COM - 90 5P MIMM1-7 MNoss PVOCN TU COf;N�t; C - 18 PFPIMMP P15TANa, a - 3' L- NOTES 0056111. PIf7GE CAP - 17 COt;NEt? AREA - 3'X 3' I7-0202 APPFOX, 00F TE5T LOCATIONS, AMAS, ANP PIMFNSIONS