RF-18-249Project Address
Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Permi
IssueDate: 21212018
Permit NO. RF -2-18-249
Permit Type: Roof
Work Classification: Flat
Permit Status: APPROVED
Expiration: 08/01/2018
Parcel Number
Applicant
352 NE 98 Street
Miami Shores, FL
1132060135690
Block: Lot:
RAUL NOBILI
Owner Information
Address
Phone
Cell
RAUL NOBILI
352 NE 98 ST
MIAMI SHORES FL 33138-2410
Contractor(s)
J&K ROOFING INC
Phone
954-961-7663
Cell Phone
Valuation:
Total Sq Feet:
$ 10,000.00
800
Type of Work: Re Roof
Additional Info: RE -ROOF FLAT ROOF WITH GAF CAPSHEET
Classification: Residential
Scanning: 3
Fees Due
Bond Type - Contractors Bond
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee - New Roof
Scanning Fee
Technology Fee
Amount
$500.00
$6.00
$3.75
$2.50
$2.00
$250.00
$9.00
$8.00
Total: $781.25
Pay Date
Invoice #
02/02/2018
02/01/2018
Bond #: 3629
Pay Type
RF -2-18-66293
Check #: 34181
Check #: 34167
Amt Paid Amt Due
$ 731.25 $ 50.00
$ 50.00 $ 0.00
Available Inspections:
Inspection Type:
Tin Cap
Final Roof
Roof in Progress
Renailing Affidavit
Review Roof
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoni Futherm e, I authorize the above-named contractor to do the work stated.
February 02, 2018
Authorized Signature: Owner / Applicant / Contractor / Agent
Building Department Copy
Date
February 02, 2018 1
(;_t 6) ��«��
BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
RECEIVED
FEB 011018
Of
CP 'h
FBC 2017
Master Permit No. 12,f 18 - 2L
Sub Permit No.
❑ BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL
❑ PLUMBING ❑ MECHANICAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 35,2 / y S�
City: Miami Shores
County: Miami Dade Zip: 33138
Is the Buildingj�Historically Designated: Yes NO
Construction Type: 4t 7 Flood Zone: BFE: FFE:
Folio/Parcel#: ))- 0 " 0/3 - go
Occupancy Type: Load:
OWNER: Name (Fee Simple Titleholder): Ra kl Q33; 11
Address: £a Nit
E /0 5+
Phone#:
City: M a.M ; S reS
State: ! 1 Zip: 33 \3R
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: '�K- V400trnet Phone#: 9311 Yid 9/ /
Address: 2610 511 erMGcn S�
City: i4tA4) State: Ft
Qualifier Name: 1JQ,rt,n le y er(o,J Phone#:
State Certification or Registration #: CL' CO 3- 0,S- 1 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ /0, QO 0 •00 Square/Linear Footage of Work: 80 0
Zip: 370a O
9Szi; > 9�2- �az9
Type of Work:
❑ Addition ❑ Alteration
n p `7
/� ) t ❑ New ` V Repair/Replace
Description of,Worki /GIJ Q,f t 7" / -4 rota "/ .,F CGn ,ihee 7
❑ Demolition
Specify color of color thru tile: Fed (001'
Submittal Fee $ Permit Fee $
Scanning Fee $ Radon Fee $ DBPR $
Technology Fee $ Training/Education Fee $
Structural Reviews $
CCF $ CO/CC $
(Revised02/24/2014)
Notary $
Double Fee $
Bond $ 5
TOTAL FEE NOW DUE $ 3
Bonding Company's Name (if applicable)
Bonding Company'sAddress .°
City
State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
;{ C
City __) State Zip
,Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien low brochure will be delivered to the person
whose property is s bject to att.cment. Also, a certified copy of the recorded notice of commencement must tie posted at the job site
for the first inspec ion which rs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not appro, e' ' ' a reinspection fee will be charged.
Signature
WNER or
ENT
The foregoing instrument was acknowledged beforemethis
a1 ,A,dd\ay of `f 44. , 20 %0 , by
gikt4) IIv01 6 I t , who is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
r. Cristobal Ortiz
NOTARY PUBLIC
_STATE OF FLORIDA
Sign:
Expires 11/13/2014int:
Signature��'�'j/j/I�L.P 97 _6_e'_/_�--
CONTRACTOR
The foregoing instrument was acknowledged before me this
qq /2_ dayof TO , 20 ,IC , by
, who is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
**********************44******1********
APPROVED BY
(Revised02/24/2014)
Seal:
Cristobal Ortiz
NOTARY PUBLIC
STATE OF FLORIDA
Comm# FF920230
Expires 11/13/2019
********************************************************************
5
Plans Examiner
Zoning
Structural Review Clerk
1/15/2018 Property Search Application - Miami -Dade County
��r
OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-013-5690
Property Address:
352 NE 98 ST
Miami Shores, FL 33138-2410
Owner
RAUL NOBILI
Mailing Address
352 NE 98 ST
MIAMI SHORES, FL 33138-2410
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
4 / 2 / 1
Floors
1
Living Units
1
Actual Area
3,470 Sq.Ft
Living Area
2,592 Sq.Ft
Adjusted Area
2,772 Sq.Ft
Lot Size
14,375 Sq.Ft
Year Built
1926
Assessment Information
Year
2017
2016
2015
Land Value
$431,422
$359,519
$345,374
Building Value
$192,931
$192,931
$192,931
XF Value
$33,166
$33,601
$22,088
Market Value
$657,519
$586,051
$560,393
Assessed Value
$324,769
$318,090
$315,879
Benefits Information
Benefit
Type
2017
2016
2015
Save Our Homes
Cap
Assessment
Reduction
$332,750
$267,961
$244,514
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (Le. County, School
Board, City, Regional).
Short Legal Description
MIAMI SHORES SEC 1 AMD PB 10-70
W1/2 OF LOT 4 & ALL OF LOTS 5 & 6
BLK 42
LOT SIZE 125.000 X 115
OR 17212-1646 0596 1
Generated On : 1/15/2018
Taxable Value Information
Previous Sale
2017
2016
2015
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$274,769
$268,090
$265,879
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$299,769
$293,090
$290,879
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$274,769
$268,090
$265,879
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$274,769
$268,090
$265,879
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
05/01/1996
$270,000
17212-1646
Sales which are qualified
12/01/1986
$135,000
13114-0904
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/discaimer.asp
Version:
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: eea 4.1 VA -11;
Date:
Property Address: 3sa N r Sf
Roofing Permit Number:
Dear Building Official:
I 4.6t.) 111#10 ' certify that I am not required to retrofit the roof to wall connections of my
building because:
.'The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o T e building` as constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1
4 ed. io
the South Florida Building Code (1994 SFBC)
Signature
RA Qc /✓O � i`f✓
Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this AR day of de t d 016
CONaz- Cristobal Ortiz
NOTARY PUBLIC
Notary Public, Sate of Florida at Large C/b/
• `<r STATE OF FLORIDA
�. " Corrrr?# FF920230
D'I'CE tialExpires 11/13/2019
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
LICENSED AND INSURED
2010 Sherman Street
Hollywood, Florida 33020
ROOFING
Se/w4e9 Sant% 7latiela dot 0cet 30 Z$eana
LICENSE # CC -C058051
954-961-7663
954-961-9879
Fax 954-925-8015
Su •ed To ff
tp1Q f, 4,6(J
Job Name
Dade
/
f l
Street N E 9 3 '
' 7 -Street
- 2, , _ _ _
_ ,
Phone 1
- A - - - r
City, St. & Zip
/.
))&
I -2110(e— c
Fe/12.
City, St. Zip
�-
Phone
�/
�
Legal
Lot
Blk
Sub
Tax Folio*
ALL ROOFS TO BE DONE AS FOLLOWS
0 SLOPE ROOFC0_5e_, ei ji"-j;c .
tear off entire existing slope Roof down to deck or smoo
worka • surface. WILL RENAIL DECKING TO MEET EX I ING
CODE. R- • ove all related roofing debris from • emises.
Replace any nec sary wood, LF, or Sq. for plywood
free. per ft. -ereafter.
Will apply 30 Ib. p mium felt, • ° hored to the deck
according to local building •de ill install all new metal
flashing and lead stacks. USI OT ASPHALT, MOP a 36
INCH WIDE STRIP OF 30 B FELT ERTICALLY AND a 16
INCHWIDEGALV.VAL METAL IN ALL • LEYS.
Mop with Ho sphalt to said
30Ib's. Embe tile in
system.
Will tear off entire existing flat roof down to deck or smooth
workable surface. WILL RENAIL DECKING TO MEET EXISTING
CODE. Remove all related roofing debris from premises.
Replacg any necessary wood, /00 LF, or Sq. ft for plywood
free. � perk thereafter.
Will apply 1 ply of I - basesheet anchored to the deck
according to local building code. Using HOT ASPHALT, will mop
plys of fiberglass felts to said basesheet. Install all new
metal flashing and lead stacks.
Using HOT ASPHALT mop 1 ply fiberglass cap
sheet to said fiberglass.
❑ Using HOT • , mop 1 ply MODIFIED
BITUMEN to - I s • erglass felt.
❑ Wil
arock.
od coat with hot as . alt and embed
We hereby propose to furnish labor and materials - complet= in accordance wiy9he above specifications, for the sum of
dollars 0 �0 )with payment to be made as follows:
;MO 1)0L.Itr..) It, L D "A
No carpentry work, woodwork or painting unless specifically tated in this contract.
In the event payment is not make as stated in payment schedule, All fees incurred in collections, such as,
but not limited to, attorney fees, court costs and collection agencies, are to be paid by signer or owner.
co
VERAG
E ]
The roof applied to the building described above is guaranteed for 1 0 years from the date of completion upon final payment in full.
This guarantee is TRANSFERABLE AT NO CHARGE to new owners of the property. Under this guarantee, the roofing contractor will, at its own
expense, make any repairs necessary to correct roof leaks resulting from the following causes:
1. Failure of roofing felts or base flashing resulting from usual and ordinary effects of wear and weather.
2. Poor workmanship of roofing contractor in applying roofing and flashing materials.
EXCLUSIONS
This guarantee does not cover:
1. Leaks or other damage caused by:
a. Natural disasters, including but not limited to floods, lightning, hurricanes, hail, windstorms, earthquakes, tornados, dry rot, etc.
b. Structural failures such as cracks in decks, walls, partitions, foundations, windows, stoppage of roof drains or gutters, etc.
c. Changes in the original principal usage to which of the building, unless approved by the contractor in advance in writing.
d, Erection or construction of any additional installation on or through the roofing felt after the date of completion.
e. Roof or flashing repairs by others, painting or coating without approval.
f. Riots or vandalism.
g. Termites or other insects.
h. Penetration of the roofing from beneath by rising nails.
2. Damage to the building or it's contents, roof insulation, roof deck or other base over which roofing felt is applied.
ACTION
In the event leaks from roofing should occur, owner shall notify contractor promptly. Contractor will inspect the roof, and if cause of leak is
within the coverage as stated above, the contractor will arrange for repairs to be made at no cost to the owner. If cause of leak is not covered,
contractor will not be responsible for cost of any repairs.
In the event leaks are not covered under the terms of this guarantee, a service charge will be invoiced to the owner. The guarantee will become
null and void if payment of the service charge is not made within 30 days of the billing date.
WE MAKE NO GUARANTEES OF ANY KIND, EXPRESSED OR IMPLIED, ; STATED HEREIN.
ACCEPTANCE OF PROPOSAL: The above prices, specifications
and conditions are satisfactory and are hereby accepted. You are
authorized to do the work as specified. Payment will be made as
outlined above. I have read & understand the back of this contract.
I understia
i the wood clause.
DATE 1 ' V8
. ROOF ASSEMBLES AND ROOFTOP STRUCTURES
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
15.36
SECTION 1525
HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPUCATION
Florida Building Code 5th Edition (2014)
High Velocity Hurricane Zone Uniform Permit Application Form
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT
APPUCATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW
Roof System
Required Sections of the
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR -RAS 150
A,B,C
4,S,S,7 . `.
Shingles
A,B,D
•Asphaltic
1,2,4,5!8'7 • • a
Concrete or Clay Tile
A,B,D,E
1,2,3,4 5g9 •
Metal Roofs
A,B,D
1,2,3,425A/7..
Wood Shingles and Shakes
A,B,D
1.2,4,5x1 ` • •
Other
As Applicable1,2,3,448J„`
•
- `• 1
•
ATTACHMENTS REQUIRED:
• • .
. •
INTERNATIONAL CODE COUNCIL'
..•
•
.•.
. .
.
• . •
•.
.
•••
.
••.
.
. •
• .
•
• .
•. . . •
• • •
.. .
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or licensed by,ICC (ALL RIGHTS RESERVED); accessed by Mina Palacio on Jun 8, 2015 10:32:12 AM pursuant to license
Agreement. No further reprduction authorized.
• •
1.
Fire Directory Listing Page • • • `
•
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
INTERNATIONAL CODE COUNCIL'
..•
•
.•.
. .
.
• . •
•.
.
•••
.
••.
.
. •
• .
•
• .
•. . . •
• • •
.. .
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or licensed by,ICC (ALL RIGHTS RESERVED); accessed by Mina Palacio on Jun 8, 2015 10:32:12 AM pursuant to license
Agreement. No further reprduction authorized.
Master Permit No.
Contractor's Name
Job Address
-2e-cAV SkPfl
• Asphatlic Shingles
ROOF ASSENBUES AND ROOFTOP STRUCTURES
Rodda Building Code flith Edition (2017)
High -Velocity Hurricane Zone Uniform Pent* Application
Section AlGeneral information)
2:1L A214:k
3sa /Jr sy-
O New roof
0 Repair
Low Slope Roof Area (SF) E 0
0
ROOF CATEGORY
0 Mechanically Fastened Tile
13 Metal Panel/Shingles
O Plescriptive BUR -RAS 150
ROOF TYPE
0 Maintenance
ROOF SYSTEM INFORMAZ
Steep Sloped Roof AREA (SSF)
• 0 Mortar/Adhesive Set Tiles
0 Wood Shingles/Shakes
Reroofing
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers. overflow scuppers ancCoveraw drains. Include dime. :1
sions of sections and levels, clearly identify dimensions of elevated pressure zones and Eocatlon of parapets. ••
• • • •
. •
• . .
• 1
r
.
• •
.•
.
:
1:::TeleiNF)S01)..1
• •
• • • •
• •
. •
1
1
. • .
• • . • • .
• . •
RECEIVED
-FEB 1 1018
APFR
ZONINC
BLDG Ef5t
attic -11.
• Miami Shores Village
o-UBJE
1.0 C;Ck1PLIANCE-WISH A1.1
EEDERAL
STATE Nu Cr ,I.Jyr-Y—cia..L.E'sS AND REU1fl
FLORIDA BUILDING CODE — BUILDING, 61h EDITION (2017)
.11
•
1
469
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section C (Low Sloped Roof System)
Fill in Specific Roof Assembly Components,
and Identify Manufacturer
(If a component Is not used. Identify y as "NA')
System Manufacturer: `! r
NOA No.; /4 /0.3 0- 01
Design Wind Pressures, From RAS 128 or Cahxrlations:
Prnaxl: 42' k Pmax2; 71-7 Pmax3: /04.4
Max. Design Pressure, From the Spm NOAsa S
Deck
Type: wooGauge/Thidmess:
„
�a�Slope; "
Anchor/Base Sheet & No. of Ply(s):
AnchodBase Sheet FastenedBonding Material:
Insulation Base Layer:
Base Insulation Size and Thidu ass:
Base insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation SIze and Thickness:
Top Insulation Fastener/Bonding Material:
Fastener Spacing for Anchor/Base Sheet
Attachment
Fief& L ' oc @ Lap. Si Rows
Perimeter: 10 ' oc @ Lap. # Rows A.e ' oc
Comer JL' oc a Lap, # Rows e oc
Number of Fasteners Per insulation
Board _ A
Field Perimeter Corner
Illustrate Components Noted and
Details as Applicable:
Woodbloddng, Gutter, Edge Termination,
Stripping, Flashing, Continuous Cleat, Cant ...
Strip, Base Flashing, Counter- Jiashinti. • .. •
Coping, Etc.
• . •
..• .. .. •
indicate: Mean Roof Height, Pam. Heigh, • .. •
Height of Base Flashing, Compgr rit 4aterial,
Material Thidaress, Fastener Typp, Fastener • • •
Spadng or Submit Manufacturer% Details that • • • •
Comply with RAS 111 and Chapter ft#.
oe\''
NIt
r 0_2
071 /34Y Sited -
•
• •
•• ••
1.--.--
••
••
Base sheet(s) & No. of Ply(s): /44.- /4A e J hee4-
Ply Sheet(s).& No. of PIy(s): eZ p%
Ply Sheet
lyits t, t1
rt Da at"t.I L
Top Ply- erJn�a.SS Ccies Lee 7
Top7YFastener/ite het BondingMaterial:, i �
Surfadng: /1)AA'
•
• •
•
FT.
• •
•
•
• •
•
•• •
,• •
•
FT.
Parapet
Height
10
Mean
Roof
Height
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer.
Notice of Acceptance Number:
Minimum Design Wind Pressures. If Applicable (From RAS 127 or Calculations):
P1: P1: P1:
Roof Slope:
: 12
Deck Type:
Type Underlayment
Insulation:
• •
•
..
•. •
•••.
• • •
• •.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
• 1.•..
Mean Roof Height:
Type: I
. • .
•. •
Type Cap Sheet
•• •
-- •
Roof Covering:
Type & Size Drip
Edge:
. .
. 1....
.1...
• 41
.i...
.1....
1
al •
1....
1
1
1
1
1
1
1
1
1
1
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39
Copyright to, or licensed by. ICC (ALL RIGHTS RESERVED)amassed by EirACT Palacio on Jun 8.2015 10.32:12 AM pursuant to license
Agent No further reproductions authorized
INTERNATIONAL CODE COUNCIL
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
1
1
1
High -Velocity Hurricane Zone Uniform Permit Application Form.
1
Section E (Tile Calculations)
1 For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M. If the M, values
are greater than or equa to the Mr values, for each area of the roof, then the tile attachmnt method is acceptable.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Method 1 'Moment Based Tile Calculations Per RAS 127"
(P1:_ x X = ) – Mg: = M„ Product Approval M,
(P2: xX = ) – Mg: = Mrz Product Approval M,
(P3: xX = ) – Mg: = M, Product Approval M,
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval M,
'Must be u
I Appeals.
Mr required Moment Resistance*
•• •• ••.
• •
Mean Roof Height-
Roof Slope
15'
20'
25'
30'
•••••40'
• •
•
-
•
2:1234.4
Job Site
36.5
38.2
39.7
••••••
42.2
Product Approval
3:12
32.2
34.4
36.0
37.4
•
....39 8
• .
4:12
30.4
32.2
Calculated
35.1
...
•.37.3
•
5:12
28.4
30.1
32.8
.
• •.34.9
.
•
6:12
26.4
8.0
rk/3.8
30.5
•• ;'Z.4
7:1224.4
2 9
28.2
•
•30.0
• r
I For Uplift based tile systems use Method 3. Com ared u
1 equal to the Fr values, for each area of the roof, t n the ti
1
I '(P1:_xL
1 (P2:_ x L
I (P3:x L
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Y•.
•
•••
•
• • •
••
•
•
•
•
•...
•
•.
•
rsed by the Broward Ceenty'Board pf Rplbp and •
•. •
with tt values for Fr. if the F' values are greater than or
method is acceptable.
Method 3 'Uplift Based Tile alcula'*ons Per RAS 127"
= x w = ) – W: x cos g = Fr, Product Approval F'
= x w: _ ) – W: x cos O = Q Product Approval F'
Product Approval F'
= xw:=J–W: xcos9 = Ft,
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
9
Job Site
Aerodynamic Multiplier
7l
Product Approval
Restoring Moment due to Gravity
M9
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
M0
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L =:length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
15.40
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or Goosed by. ICC (ALL RIGHTS RESERVED); accessed by Elieur Palacio on Jun 8.201510.32:12 AM pursuant to License
Agreement No further reproductions authorised.
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the t' esignated space indicates that the item has been explained.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck•mey4�ave to •
be re lied in accordance with the current provisions of Section R4403. (The roeTdeck is uueglly, • • • i
concealed prior to removing the existing roof system). • . ..
.
.
e... •... .
•
•
4. ', = " Exposed Ceiling: Exposed, open beam ceilings are where the uric�e�sige of t ; r decking
•..•••
n be viewed from below. The owner may wish to maintain the architectural • • • • •Ince; et ffCt2,
roofing nail penetration of the underside of the decking may not be acceptable lis provides the option of .'
maintaining the appearance. . •• .•
• •
• • .
•• • .• ••
6. .►' Overflow scuppers (wall outlets): It is required that rainwater flows off so that th% rbof is
••
t overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
dischar•e if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
up in accordance with the requirements of Sections R4402, R4403 and R4413.
gent's Signature Date
55 N qfi 5�.
Property Address
Revised on 7/9/2009 LD;07101/2015;
Permit Number
4
MIAMFQADE
COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF
1 Campus Drive
Parsippany, NJ 07054
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
www.miamidade.eov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
.•••
This NOA shall not be valid after the expiration date stated below. The Miami -Dade CQunrroduct• • • • •
�y
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dad8 Cdlmty): • . • .
reserve the right to have this product or material tested for quality assurance purposes. UM product o�
material fails to perform in the accepted manner, the manufacturer will incur the expensg phisuch tes�ig •
and the AHJ may immediately revoke, modify, or suspend the use of such product or n att: i F wi fl tu'
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by M WDade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
. • •
.
•
.
This product is approved as described herein, and has been'designed to comply with the FIoI da Bu1d i!i tode .
including the High Velocity Hurricane Zone of the Florida Building Code. • • ••..... ••
DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31.
The submitted documentation was reviewed by Jorge L. Acebo.
MIAMFDADE COUNTY
APPROVED
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 1 of 31
Membrane Type:
Deck Type 1I:
Deck Description:
System Type E(3):
BUR
Wood, Non Insulated
Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and
intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max.
Anchor sheet mechanically attached to roof deck.
All General and System Limitations shall apply.
Fire Barrier:
(optional)
Anchor sheet:
Fastening
Option #1:
Fastening
Option #2:
Fastening
Option #3:
Fastening
Option #4:
Fastening
Option #5:
Ply Sheet:
TOPCOAT FireOut'" Fire Barrier Coating, VersaShield® Fire -Resistant Shp Sheet or
VersaShield® Solo"' Fire -Resistant Slip Sheet installed per manufacturer's installation
instructions.
GAFGLAS® #75 Base Sheet, Tri -Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAF tratavent® Venting Nailable Base Sheet is secured as described below.
Miami -Dade County Approved min. 12 ga. annular ring shank nailsand min! 1 S/8 in.
diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anetw sheet side el& s and g • .
in. o.c. in the field of the sheet in two staggered rows. ••• •. • •
(Maximum Design Pressure: —45 psf. See General Limitation44..
•
•
Miami -Dade County Approved min. 12 ga. annular ring shank'ty�,} Ind mini 1- 8 in. •
•
.
diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anahas skeet side lags and 6 •
. .
4 in. o.c. in the field of the sheet in two staggered rows. • • • • •
(Maximum Design Pressure: —52.5 psf. See General LimitatWR ri •
Drill -Tec'' #14 Fasteners and Drill -Tec"' 3 in. Standard Steel Plates, Drill—M"• •
.
.
•
AccuTrac® Flat Plates or Drill -Tec"' 3 in. Ribbed Galvalume Plate (Plat) art spaced la
in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet
in two staggered rows.
(Maximum Design Pressure: 52.5 psf. See General Limitation #7)
Drill -Tee #14 Fasteners and Drill -Tec"` 3 in. Standard Steel Plates, Drill -Tec"`
AccuTrac® Flat Plates or Drill -Tec"' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12
in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet
in two staggered rows.
(Maximum Design .Pressure: —60 psf. See General Limitation #7)
Drill -Tec"' #14 Fasteners and Drill -Tec"` 3 in. Standard Steel Plates, Drill -Tec'
AccuTrac® Flat Plates or Drill -Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in.
o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in
three staggered rows.
(Maximum Design Pressure: —97.5 psf. See General Limitation #7)
When optional cap sheet is present:
Two or more plies of GAFGLAS® Ply 4, Tri -Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered
in a full mopping of hot asp It applied at 20-40 lbs./sq. installed per manufacturer' s
installation instructions.
When optional cap sheet is not present:
Three or more plies of GAFGLAS® Ply 4, Tri -Ply'® Ply 4, GAFGLAS® Flex Ply 6
adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per
manufacturer's installation instructions.
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 27 of 31
.
Cap Sheet: (Optional GAFGLAS® Mineral Surfaced Can Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS Energy ap meral Surfaced Cap Sheet adhered in a fitll.mopping.o£hQ
asps h alt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60lbs./sq.
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied at 0.5 to 0.75 galisq.(to be used as a primer) followed by
Topcoat® Membrane applied at 0.5 to 0.75 gal./sq.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Above.
MANMADE COUNTY
APPROVED
• •
....
• • .
...
.. .
• . .
• ..
.
.... ....
. .•
.... ....
. .
.. .
. . •
. .
• .
• . .
.. .
•
•
. .
.
•
. .
•
. .
. •
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 28 of 31
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply 6 when used as a mechanically fastened
base or anchor sheet.
2. Minimum 1/4" DensDeck' Roof Board or /2" Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum. • • • •
4. An overlay and/or recovery board insulation panel is required on all applications over coos ed cell fo ,vi,stlatioy�
••••
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applred us spot .'
•
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribb5iis' Di three itws,•one at
each sidelap and one down the center of the sheet allowing a continuous area of ventila on. $ncircling'of the • •
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cro%s ygntilation :A, phalt ' • '
application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attac]wLzysten1s All be•
limited to a maximum design pressure of -45 psf. • •• •• • • •
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic ForcC •itlue of 276 lbf., as .'
tested in compliance with Testing Application Standard TAS 105. If the fastener value;, as field-te$ed.x,F below • • .
•
275 lbf. insulation attachment shall not be acceptable.•
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based•gz s minimum •
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 31 of 31
10182016
ONLINE CERTIFICATIONS DIRECTORY
Paae Bottom
TGFU.R14153- Roofing Systems
TGFU.R14153
Roofing Systems
Roofing Systems
See General Information for Roofina Systems
GAF
1 CAMPUS DR
PARSIPPANY, W 07054 USA
.R14153
"Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Modified Base Sheet" may be utilized as an altemate to Type G2 base sheets in any of
the following Classifications.
1/2 -In. thick (minimum) gypsum board or 1/4 -in. thidc (minimum) Georgia-Padfic Gypsum LLC "DensDeck® Roofboard," " pp Dedk Prime®
Roofboard" or "DensDedc DuraGuardTM Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the
resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However,"t%o butt joiirfs'% the gyb3 n& •
board and Georgia-Padfic Gypsum LLC "DensDeck® Roofboard," "DensDedc Prime® Roofboard" or "DensDedt•Dur$Guardr godfpoard" are too
offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be•placed•beew the •
overiayment board. • • •
Multiple plies of "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "Tri -Ply® Ply 6" may be adhered to Georgia-Padfic t y um LLV"b'eftsDedc
Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" in hot roofing asphalt. • • • • ••••
• •
"EnergyGuardTM Ultra" is an acceptable altemate to "EnergyGuard' RF" in any applicable Classification. • • • • • •
•
•
• •
"GAF Stratavent® Eliminator" Venting Base Sheet (Nailable)" may be mechanically attached or hot mopperb4IP tioncombustfbie decks and• °
as a recover over existing roof systems. • . . • •
"GAFGLAS® Perlite Insulation" may be utilized as a cover board over "EnergyGuardTM RP insulation in any of the following systems
.• • .• • •
• •
Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified ietethane insulation
adhesive. Polystyrene referenced in any of the following Classifications include "EnergyGuardTM IPS Insulation".
Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation
instructions (excluding LRF Adhesive 0) in any applicable Non -Combustible Roof Deck Classifications.
References to glass fiber insulation indude "EnergyGuard Fiberglass Insulation".
"EnergyGuardTM Tapered" is an acceptable alternate to "EnergyGuardTM" in any applicable Classification.
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or '"Tri -Ply® #75 Base Sheet", or "GAFGLAS® #80 ULTIMA") is a
suitable altemate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS® Ply 4" or "Tri -Ply® Ply 4", or "GAFGLAS® Ply 6") in the Gass A, B
or C roof systems indicated below.
The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent® Eliminator"" Venting Base
Sheet (Perforated)" or "GAF Stratavent® Eliminator" Venting Base Sheet (Nailable)." Perforated base sheets to be loose laid or fully adhered
with hot roofing asphalt and nallable base sheets are to be mechanically attached granule side down.
•
As an option Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or "GAFGLAS® #80 ULTIMA"
or "GAF Stratavent® Eliminator" Venting Base Sheet (Nailable)" may be substituted for Type 61 asphalt glass fiber ply sheet ("GAFGLAS®
Ply 4" or "Tri -Ply® Ply 4° or "GAFGLAS® Ply 6") as the nailed base ply in the following systems.
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened.
Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened.
"GAFGLAS® Flashing" or "Ruberoid®" may be used for flashing in any of the Class A, .B or C systems listed below.
When "pedite" is referenced, this indudes "GAFTEMP PERMALITE®" or any other UL Classified periite insulation.
Crushed stone or slag are suitable altemates for gravel in any of the Class A, B or C systems listed.
Structural cement fiber building units are considered suitable to be induded as a deck in the following Class A, B or C systems listed over C-
15/32 or NC.
The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of -in. minimum
thick gypsum board is an acceptable altemate for minimum insulation over C-15/32 thidc roof decks.
The use of polystyrene insulation board between minimum /-in. thick periite board and deck with rosin paper (perlite/rosln
paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems.
httpJ/database.ul.corn/cgi-birYXYVAemplatalLISEXT/1FRAME/showpege.html?name=TGFU.R1415`i8 nshortbtlf Roofirg+Systems&obji&1 7&f... 1/49
101182016 TGFU.R14153 - Roofing Systems
"EnergyGuardTM RA" or "Tapered EnergyGuard' RA" or "EnergyGuard " Composite RA" may be substituted for any Atlas Roofing Corp.
polyisocyanurate insulation in any of the following Classifications.
Trumbull "Perma Mop' may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt".
"GAFGLAS® #80 Premium Base Sheet" may be used in any of the following systems.
"GAFGLAS® Flex Ply 6" and "Tri -Ply® Ultra -Flexible Ply 6" are suitable altemates to "GAFGLAS® Ply 6".
"GAFTEMP Permalite Recover Board' may be used in lieu of any perlite insulation in any of the following NC Classifications.
Unless otherwlse indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT® Fires/geld MB" at
2Ih to 3-gal/100-ft2.
"Ruberoid® Dual Smooth" may be used as an altemate to "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT".
"Ruberoid® Mop Smooth 1.5" may be used as an altemate to "Ruberoid® Mop Smooth'.
Class A,8and C
Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes.
"Ruberoid® Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid® Mop° SBS products in any applicable Classification.
1. Deck: C-15/32
Inline: 3
Insulation(Optional): — One or more layers perlite or wood fiber orglass fiber or - . •
Y Pe polyisocyanurate or urethane tar •
periite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate conipositL i r phendh?`,' any thickt2SS.: -
Ply Sheet: — Three or more plies Type Gi or "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS®'Pty 6' hot nipped!. •
Surfacing: — Gravel. • • •
2. Deck: C-15/32 Incline: 2
•
•
•
• •
•••• •••• • •
• • • •
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane of • • • • •
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate corlitkrtnor phetilic+p�iy thickness.*
Ply Sheet: — Three or more plies Type G1 or "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS®•PIy 6. •
Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply G., Mineral Surfacer, cap Sheet " pr "GAFGLASCg-
EnergyCap'" BUR Mineral Surfaced Cap Sheet". • •• •• • • •
•
3. Deck: NC Udine: 2
• • • . .
• • •
•• • •• • • •
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, periite/potyieocyanurate
composite, perlite/urethane composite, wood fiber/polyisocyanurate composite, phenolic, 2 -in. maximum.
Ply Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4", "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet" or "GAFGLAS®
EnergyCapTM BUR Mineral Surfaced Cap Sheet.
C-15/32 Inline: 1
Slip Sheet (Optional): — Red rosin paper, nailed to deck.
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
OMG Inc "OlyBond Fastening System" or any UL Classified insulation adhesive.
Base Sheet: —QngTay-Type-G' "GAEGi A$o #7C Brie Short" or "Tri -Ply® #75 Base Sheet" (may be nailed).
Ply Sheet: — On or more plies Type G1 "GAFGLASO_ Ply 4" or "Tri -Ply® Ply 4" or GAFGLAS®`PiW6".
Cap Sheet: — One ply y ®erar A S=rfaoekdCap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS®
EnergyCapm BUR Mineral Surface Cap Sheet".
Surfacing (Optional): — "TOPCOAT® EnergyCoteTM Elastomeric Coating" applied at a rate of 2-gal/100-ft2.
5. Deck: NC Incline: 3
Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet".
Ply Sheet: — One or more plies Type Gi "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS®
EnergyCapTM BUR Mineral Surfaced Cap Sheet"
6. Deck: C-15/32 Inline: 2
Insulation: — One or more layers periite, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane
composite, phenolic, 1 in. minimum (offset a minimum of 6 -in. from plywood dedc joints).
Base Sheet: — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid® Torch Smooth" or "Ruberold® Torch Granule" or "Ruberold® Torch Granule Plus" or
"Ruberold® Mop Smooth" or "Ruberold® Mop Smooth 1.5" or "Ruberold® Mop Smooth Pius' or "Ruberoid® Mop Granule" or
"Ruberoid® Mop Plus Granule" or "ROOFMatch " SBS Modified Granular" or "Tri -Ply® SBS Modified Bitumen Membrane" or
"ROOFMatd " APP Modified Granular' or "Tri -Ply® TP -4G" or "Tri -Ply® TP -4" or "Ruberoid® Dual Smooth".
Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet' or "Tri -Ply® Mineral Surfaced Cap Sheet"or "GAFGLAS®
EnergyCapTM BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
7. Deck: C-15/32 Incline: 2
http!/dame.ul.com/cgi-binIXYV/templatalUSEXT/1FRAMFJshowpagehtml?name=TGFU.R141536ccnshorttifi Roofirg+Systems&obji&1 78cf... 2/49
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-297135
Scheduled Inspection Date: February 15, 2018
Inspector: Riveron, Alexis
Owner NOBILI, RAUL
Job Address: 352 NE 98 Street
Miami Shores, FL
Project <NONE>
Contractor J&K ROOFING INC
Permit Number: RF -2-18-249
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Flat
Phone Number
Parcel Number 1132060135690
Phone: 954-961.7663
Building Department Comments
RE -ROOF FLAT ROOF WITH GAF CAPSHEET
Passed Comments
INSPECTOR COMMENTS
False
Passed
d
Failed
Correction
Needed
Re -Inspection
Fee
No Additional inspections can be scheduled until
rednspec tion fee is paid
Inspector Comments
CREATED AS REINSPECTION FOR INSP-297100. CREATED AS
REINSPECTION FOR INSP-296477.
Februay 14, 2018
For inspections please bait (305)762-4949