Loading...
REV-17-2180'BUILDING 'PERMIT APPLICATION BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shares, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED AUG 2 9 7017 C)-( s EBC 2Q Master Permit No. RC -3-17-618 Sub Permit No. ❑ ELECTRIC ❑ ROOFING ❑� REVISION (PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CONTRACTOR 'JOB ADDRESS: 157. NW 103TH ST ❑ EXTENSION ❑RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:1121360131540 Occupancy Type: RES - Load: Is the Building Historically Designated: Yes' NO Construction Type: Flood Zone:, BFE: OWNER: Name (Fee Simple Titleholder): CASSA GROUP LLC Address:18181 NE 31 CT #509 FFE: i• Phone#: City: AVENTURA State: FL Tenant/Lessee Name: 'Email: Z;p. 33160 Phone#: CONTRACTOR: Company Name: 904 INVESTMENTS LLC 'Address: 12095 NW 44 ST Phone#: 7542451623 ?city: SUNRISE Qualifier Name: F. MARQUEZ State Certification or Registration #: CGC 1510878 State: FL Zip: 33323 Phone#: 7542451623 Certificate of Competency #: DESIGNER: Architect/Engineer: ti 'Address: City: :Value of Work for this Permit: $ "' Type of Work: ❑ Addition ❑ Alteration ,Description of Work: L$L\ i s t Q4 Phone#: Square/Linear Footage of Work: State: Zip: ❑ New ❑ Repair/Replace El Demolition OF �^,Oif i A) O v24 L < .. 4 4 7:, i+%,7 Cluj .r+.. Specify color of. color )thru tile: r Submittal�Fee $ n ,Kermit Fee $ Scanning Fee'"$'"1' '" "`"'Rado`nrFe"e'$ Technology Fee $ Training/Education Fee $ Structural Reviews $ '(Revised02/24/2014) CCF $ DBPR $ .. CO/CC $ + Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Il_ Bonding Company's Address City 1 State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip • Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a. permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of c• mencement must be posted at the job site for the first inspection which occurs seven (7) days after, the buildina hermit is is inspection will not be approvecland a reinspection fee will be charged. J Signature In the absence of such posted notice, the 1 Signature OWNER . AGENT The joyggging instru ent . s a knowledged before me this q(y'�day apf 41 L4� i5 20 ',by CCM LGig( � z� w is p rson Ily known to Cas -me or who has produced identification and who did take an oath. NOTARY PUBLIC: /1 �s ,i/ RAYMOND A. DEOUARTO s r Notary Public, State of Florida Commisslon# FF 123597 +moi, eitpires June 2, 2018 Sign: Print: Seal: • ************************** APPROVED BY (Revised02/24/2014) **** * ACTOR The foregoing instru ent w. s acknowledged before me this 2� day of� - , 20 j __, by /ULir_, ezwho is personally known to me or who has produced 1 t \ . 9/20 7.2S- as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: ll o�; Pis,; ALDO TORRES ( =� ° Notary Public - State of Florida f f .1 ? Commission # FF 997586 ******************************* K4, ''*`: �* *COMM #lrpifestfrxr►1«,*�EiQ�*`******* 1. Ln I ''',i, Imaiwir-m d JO Plans Examiner Zoning Structural Review Clerk Project: 904 Construction - Miami Shores Location: Rafter 2 x 8 Multi -Span Roof Beam [2015 International Building Code(2012 NDS)] ( 2 0.5 IN x 7.25 IN x 13.0 FT #2 - Southern Pine - Dry Use Section Adequate By: 4.5% Controlling Factor: Moment StruCalc Version 9.0.2.5 8/16/2017 8:00:17 PM CAUTIONS * Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center Live Load 0.15 IN U1028 Dead Load 0.32 in Total Load 0.47 IN L/333 Live Load Deflection Criteria: U180 Total Load Deflection Criteria: L/180 REACTIONS A Live Load 234 Ib 234 Ib Dead Load 483 Ib 472 Ib Total Load 717 Ib 706 Ib Bearing Length 0.42 in 0.42 in BEAM DATA Center Span Length 13 ft Unbraced Length -Top 13 ft Unbraced Length -Bottom 13 ft Roof Pitch 0 :12 Roof Duration Factor 1.25 Notch Depth 0.00 MATERIAL PROPERTIES #2 - Southem Pine Bending Stress: Shear Stress: { Modulus of Elasticity: Comp. -- to Grain: Base Values Adjusted Fb = 750 psi Fb' = 1123 psi Cd=1.25 CI=0.97 CF=1.23 Fv = 175 psi Fv' = 219 psi Cd=1.25 E = 1600 ksi E' = 1600 ksi Fc -1= 565 psi Fc -1' = 565 psi Controlling Moment: 2353 ft -lb 6.37 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: 717 Ib At left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Comparisons with required sections: Section Modulus: Area (Shear): Moment of Inertia (deflection): Moment: Shear: Read Provided 25.15 in3 26.28 in3 4.91 in2 21.75 in2 51.49 in4 95.27 in4 2353 ft -Ib 2459 ft -lb 717 Ib 3172 Ib LOADING DIAGRAM 1 13ft ROOF LOADING Center Roof Live Load RLL = 15 psf Roof Dead Load RDL = 27' psf Roof Tributary Width Side One TW1 = 1.2 ft Roof Tributary Width Side Two TW2 = 1.2 ft• •••• • Wall Load WALL = • 0 plf • • • • • • • • POINT LOADS - CENTER SPAN Load Number One Live Load 0 Ib Dead Load 45 Ib Location 5 ft •••• • • ••• • • • • ••• •. • •. • • .• • • •• • • • PEAM LOADING • ;enter ; ,•••• Total Live Load • • • • 36 plf • • • • Total Dead Load (Adjusted for Roof Pitoht • • 65 plf • Beam Self Weight • • 5 pli • Total Load • • 106 pe • • • .• • • • •• • ••. • • • •• a • STRUCTUr REV APPROVED Project: 904 Construction - Miami Shores Location: Joist 2x8 Multi; Span Roof Beam [2015 International Building Code(2012 NDS)] 1.5 IN x 5.5 IN x 10.0 FT #2 - Southem Pine - Dry Use Section Adequate By: 32.1% Controlling Factor: Moment DEFLECTIONS Center Live Load 0.27 IN L/445 Dead Load 0.05 in Total Load 0.32 IN L/372 Live Load Deflection Criteria: U180 Total Load Deflection Criteria: L/180 REACTIONS A Live Load 200 Ib 200 Ib Dead Load 39 Ib 39 Ib Total Load 239 Ib 239 Ib Bearing Length 0.28 in 0.28 in BEAM DATA Center Span Length 10 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 10 ft Roof Pitch * 0 :12 Roof Duration Factor 1.25 Notch Depth 0.00 MATERIAL PROPERTIES #2'- Southem Pine Bending Stress: Shear Stress: Modulus of Elasticity: Comp. -I- to Grain: Base Values . Adjusted Fb = 750 psi Fb' = 1 1250 psi. Cd=1.25 CF=1.33 Fv = 175 psi Fv' = 219 psi Cd=1.25 E = 1600 ksi E' = 1600 ksi Fc - = 565 psi Fc - = 565 psi Controlling Moment: 596 ft -lb 5.0 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: -239 Ib At right support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Comparisons with required sections: Section Modulus: Area (Shear): Moment of Inertia (deflection): Moment:, Shear: R 5.73 in3 1.64 in2 10.06 in4 596 ft -lb -239 Ib provided 7.56 in3 8.25 in2 20.8 in4 788 ft -Ib 1203 Ib StruCalc Version 9.0.2.5 4 8/16/2017 8:00:17 PM page LOADING DIAGRAM 10ft ROOF LOADING Roof Live Load Roof Dead Load Roof Tributary Width Side One Roof Tributary Width Side Two Wall Load Center RLL = 15 psf RDL = 2 psf TW1 = 1.3. ft TW2 = 1.3 ft WALL -= 0 plf BEAM LOADING Center • • Total Live Load • 40 plf •••••• Total Dead Load (Adjusted for Roof Pitch)* •6 plf Beam Self Weight . • 2 plf • • • • Total Load • k8 plf `1. • • •• •••• t • • .••• • • •• •• • • • • • • • • •• • •• • • I• • • 1 •• • •• • • • •••• • • • • ••• •-. • • •• • • • ••••e, • • .• • • • NOTES {