FW-16-2053Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Permit Permit NO. -W-7-16-2053 Permit Type: FenceA all Wort( Classification: Wire Fence Permit Status: APPROVED Issue Date: 8/1/2016 Expiration: 01/28/201"i Parcel Number Applicant 11300 NE 2 Avenue Number: Landon Studer 1121360010160-32 Miami Shores, FL 33138-0000 Block: Lot: BARRY UNIVERSITY INC Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractors) FIRST FENCE USA INC. Phone (305)528-6940 CeII Phone Valuation: Total Sq Feet: $ 28,000.00 400 Approved: Comments: Date Approved: : Date Denied: Type of Construction: Wire Fence Classification: Commercial Additional Info: Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Notary Fi-ree Permit Fee - Wire & Wood Scanning Fee Technology Fee Amount $16.80 $6.00 $6.00 $5.60 $5.00 $400.00 $9.00 $22.40 Total:—, $470.80 r-* L7. Yti? C7":t Pay Date Invoice # 07/21/2016 08/01/2016 Pay Type FW -7-16-60693 Check #: 2282 $ 200.00 $ 270.80 Credit Card a $ 270.80 $ 0.00 Amt Paid Amt Due Available Inspections: Inspection Type: Final Foundation Review Planning Review Building In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining;pereto and in strict conformity with the 'plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting.ais permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERSTAF constructio VIT: I certify1ra II the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating I authorize the above-named contractor to do the work stated. zonin ,61=r thor:Owner / Applicant / Contractor / Agent Building Department Copy August 01, 2016 Date August 0172016 1 Aviv' 21 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20\4 6111 Master Permit No. - -1NJ \ b 2053 Sub Permit No. 'BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL 0PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CON ACTOR DRAWINGS JOB ADDRESS: //Jc)0 ifilE c7'6/4"1 -5C+ ' " g a/) _ -V City: MiamiShoresCounty: Miami Dade Zip: 33/ Folio/Parcel#: //C9/®®VSO Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee/Simple Titleholder): GZirj/ Cif 7;ai J Phone#: Address: /`` 4 00 It/ r2 41 NI 4 City: /114•77✓ SAdrii a State: re_ Zip: ._.13 /3J, Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: l' .L%'�'S/ (}5,4 .7 C' Phone#: 30,-.5.A9 6 ve) Address: R7,5Z) £c) 96',,5f City: Qualifier Name: ®%%�iifYs ; State: Or) 04-17 Zip: Phone#: 305:5;2616 97'0 State Certification or Registration #: Certificate of Competency #: e.)e)6 DESIGNER: Architect/Engineer: /20 iIZ— Phone#: Address: City: State: NM' Zip: Value of Work for this Permit: $ C2) 6 OZ V Square/Linear Footage of Work: f7 M Type of Work: ❑ Addition Desccription ork:L i ete Alter tion epair/Replace r ❑ Dem on L Ge Specify color of color thru tile: Submittal Fee $ 5 ' ( Permit Fee $ 4CS ° CCF $ ! 6 • �j � co/CC $ Scanning Fee $ Radon Fee $ c • c0 DBPR $ 6 a Ci® Notary $ '(3Z) Technology Fee $ ' C 0 Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ 0 TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City i State Mortgage Lender's Name (if applicable) Mortgage Lender's A Zip Cit State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE_ RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature A0.01/1 OWNER or AGENT The fcregoing�instrument was acknowledged before me this �" ' day of S , 20 ICI , by N Qmse Tt AL , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: APPROVED BY Signa CONTRACTOR The foregoing instrument was acknowledged before me this cZ IS* day of 001.9 , 20 IG by RonOeL P,. , who is personally known to me or who has produced - 'I' x L CLQfS"L as identification and who did tak NOTARY Sign: Print: Seal: 0 k.kEk VANADY PR Et' : g, %,.,s MY COMMISSION (' FF 214031 hn EXPIRES: March 25, 2019 ', it doe Bonded Thni Notary Pubs Underwriters Plans Examiner )-1'0 Zoning Structural Review Clerk (Revised02/24/2014) FLORIDA NOT FOR PROFIT CORPORATION ANNUAL REPORT _OCUMENT# 711458 Entity Name: BARRY UNIVERSITY, INC. Current Principal Place of Business: 11300 N.E. SECOND AVENUE ROOM 105 FARRELL HALL MIAMI, FL 33161 Current Mailing Address: 11300 N.E. SECOND AVENUE ROOM 105, FARRELL HALL MIAMI, FL 33161 FEI Number: 59-0624364 Name and Address of Current Registered Agent: DUDGEON, DAVID 11300 NE SECOND AVE LAVOIE HALL #209 MIAMI, FL 33161 US FILED Apr 29, 2016 Secretary of State CC6561401448 Certificate of Status Desired: No The above named entity submits this statement for the purpose of changing its registered office or registered agent, or both, in the State of Florida. SIGNATURE: DAVID DUDGEON 04/29/2016 Electronic Signature of Registered Agent Officer/Director Detail : Title Name Address City -State -Zip: Title Name Address City -State -Zip: S DUDGEON, DAVID 11300 NE SECOND AVE MIAMI FL 33161 D BUSSEL, JOHN 11300 NE SECOND AVE MIAMI FL 33161 Title Name Address T ROSENTHAL, SUSAN 11300 N.E. SECOND AVENUE ROOM 105 FARRELL HALL City -State -Zip: MIAMI FL 33161 Title Name Address City -State -Zip: PD BEVILACQUA, SISTER LINDA 11300 NE SECOND AVE MIAMI FL 33161 Date I hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath; that I am an officer or director of the corporation or the receiver or trustee empowered to execute this report as required by Chapter 617, Florida Statutes; and that my name appears above, or on an attachment with all other like empowered. SIGNATURE: DAVID DUDGEON SECRETARY 04/29/2016 Electronic Signature of Signing Officer/Director Detail Date BUILDING PERMIT APPLIC XI -BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑ ROOFING REVISION RECEIVED NOV 14 2016 Acbc - F�BC20(q er Permit No. Fly>7 "/6 — c7OJ 'ub Permit NoFkJi ()r 3� (0) ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CO NT1.onify, RACTO R PE o7/ Ave 541. County: Miami Dade Zip: 33/J JOB ADDRESS: 17300 City: Miami Shores DRAWINGS Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Fesie.L- Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): 160 it7 tL2P?/J,t$/7` Phone#: Address:/13 OV n% F cc! 4 (/L JJ 4 �` o City: kit/ a eri ; „5-176,its State: / - Zip: .l J/_J Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: )tJ k;Piee v ✓A 7-44/e_ Phone#: 305.5-07476 / �d 9?v cd ygs7' City: � te: Zip: 33/65' Qualifier Name: 9-/11, /A�<& h im Address: State Certification or Registration #: DESIGNER: Architect/Engineer: Address: Value of Work for this Permit: $ Type of Work: 1 1 Addition D ripti n of Wor : fWe5 /�S /J V pe ❑ Altera o F1JJ Phone#: SD.S"5:978 (P5/6 Certificate of Competency #: Phone#: City: State: Zip: Square/Linear Footage of Work: ,i New: ❑Repair/Rep ce .5,C� ❑ Demoli n J.-)61, A Z.-a/W. Specify color of color thru tile: Submittal Fee $ SCJ Permit Fee $ ' 60 Scanning Fee $ Q • 07 Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ lRevispd12/74/70141 CCF$ DBPR $ CO/CC $ , Notary$ b •a) Double Fee $ Bond $ TOTAL FEE NOW DUE $ At f ii ', 1+ c t1 Bonding Company's Name (if applicable) i ` I%R-- Bonding Company's Address City State Zip Mortgage'Lender's Name (if applicable) Mortgage Lender's Address Cityk.State ; a -*; t`i '-- ..t f-. ') ` .0k Zip • .: : F . 1; �,i . r- ,h '� i' i it y k al A ' r ' i Application is hereby made to obtain a permit to doth viiork'dn'd'in`stallatioris as indicated.`'I'certify that no work or installation has commenced prior to the issuance -of a permit and that all work Will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ti "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." • Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature 4//0.01\ OWNER or AGENT Signature CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this I� day of O+W"/' "rq- , 20 (( , by day of ( M e_ , 20 tCm, by SUSAN `AGJU44L/ , who is personally known o1ONdt-J-- I WO , who is personally known to c-- nn'' as me or who has produced ti:Da.1 N as identification and who did take an oath. me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: NOTARY PUq{1DIC: Seal: Notary Public State of Florida Sindia Alvarez My Commission FF 156750 Expires 0910312018 **************************************j.*_ * **************** ********* APPROVED BY Plans Examiner ID asfienrini /7A 11,19 Al Structural Review Clerk 4 JUL ,21,2016 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CHAIN LINK FENCE DESIGN DETAIL Fence Height (ft) Terminal Post Dimensions (in inches) (o.d. X wall thickness) Line Post Dimensions (in inches) (o.d. X wall thickness) Terminal Post Concrete Foundation Size (diameter X depth) (in inches) Line Post Concrete Foundation Size (diameter X depth) (in inches) U to 4 2 3/8 x 0.042 1 5/8 x 0.047 10 x 24 8 x 24 Over 4 to 6 2 3/8 x 0.042 1 7/8 x 0.055 10 x 24 8 x 24 For SI: 1 inch = 25.4 mm. NOTES: 1. This table is applicable only to fences with unrestricted airflow. 2. Fabric: 12 '/z gauge minimum, Black or Green. 3. Tension bands: Use one less than the height of the fence in feet evenly spaced. 4. Fabric Ties: Must minimum the same gauge of the fabric. 5. Fabric Tie Spacing on the Top Rail: Five ties between posts evenly spaced. 6. Fabric Tie Spacing on Line Posts: One less than height of the fence in feet, evenly spaced. 7. Either top rail or top tension wire shall be used. 8. Braces must be used at Terminal Posts if top tension wire is used instead of Top Rail. 9. Post Spacing: 10 foot (3m) on center maximum. 10. Post shall be embedded to within 6 inches (152 mm) from bottom of the foundation. 11. In order to follow the contour of the land, the bottom of the fence may clear the contour of the ground by up to 5 inch (127 mm) without increasing table values to the next higher limit. NOTICE TO PROPERTIES WITH POOLS: If the fence is to meet the criteria as a pool barrier, the fence shall not be climbable and all rails must be placed facing the inside of the property. Pedestrian gates shall have self-closing and latching devices installed at the minimum of 54" above ground. For further details see Section R4501.7.1 of FBC. Rev. 10-08-15 I. Naranjo Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CHAIN LINK FENCE DESIGN DETAIL (ACCORDING TO THE F.B.C. SECTION R4408.11) TABLE R4408.11 CHAIN LINK FENCE MINIMUM REQUEREMENTS Fence Height (ft) Terminal Post Dimensions (in inches) (o.d. X wall thickness) Line Post Dimensions (in inches) (o.d. X wall thickness) Terminal Post Concrete Foundation Size (diameter X depth) (in inches) Line Post Concrete Foundation Size (diameter X depth) (in inches) Upto4 23/8x0.042 15/8x0.047 10x24 8x24 Over 4 to 6 2 3/8 x 0.042 1 7/8 x 0.055 10 x 24 8 x 24 For SI: 1 inch = 25.4 mm. NOTES: 1, This table is applicable only to f- i_ -s with unrestricted airflow. . 2. Fabric: 12 % gauge minimu lir Green. • • • 3. Tension bands: Use one less than the height of the fence in feet evenly spaced. • •• • • • 0 • • 4. Fabric Ties: Must minimum the same gauge of the fabric. 5. Fabric Tie Spacing on the Top Rail: Five ties between posts evenly spaced. • • Y • 6. Fabric Tie Spacing on Line Posts: One less than height of the fence in feet, evenly spaced. • a. • • • • - 7. Either top rail or top tension wire shall be used. •, ®, ` • , 8. Braces must be used at Terminal Posts if top tension wire is used instead of Top Rail. • • • • 9. Post Spacing: 10 foot (3m) on center maximum.° 10. Post shall be embedded to within 6 inches (152 mm) from bottom of the foundation. •••000 , , • 11. In order to follow the contour of the land, the bottom of the fence may clear the contour of:he arodnd by up to 5 inch •••••- (127 mm) without increasing table values to the next higher limit. • • • • • •••••• • • •••••• • • NOTICE TO PROPERTIES WITH POOLS: • • •'•••• •• • •••• • • • t • •• • If the fence is to meet the criteria as a pool barrier, the fence shall not be climbable and all rails must be placed facing the inside of the property. Pedestrian gates shall have self-closing and latching devices installed at the minimum of 54" above ground. For further details see Section R4401.7.1 of FBC. CONCURRED Created on 5/22/2009 MLDV;06/22/2015