Loading...
DS-18-168CLIENT: PROJECT: CONTRACTOR: PROJECT LOCATION: WINGERTER LABORATORIES, INC. Engineering Testing inspection Services 1820 NE 144th Street, North Miami, FL 33181 - TELEPHONE: 305-944-3401 FACSIMILE: 305-949-8698 FIELD DENSITY TEST So Fla Landscape, Inc. John Bowe Residence 10666 NE 10th Ct., Miami Shores, FL REPORT NO: 1 ORDER NO.: 18-1052 TEST DATE: 2/8/2018 TIME IN: 12:15 PM INSPECTOR: Dave E Walker PAGE NO.: 1 of 1 P.O. #: PERMIT #: TIME OUT: 01:00 PM DENSITY TEST• PROCTOR INFORMATION Lab Field Fill No. Test # Lift 235 236 237 1 2 3 F F F Field Test Location: Driveway. 5ft Southeast residence 8ft West of driveway edge 6ft East of residence entrance Retest of Lab No Moisture (%) 7.1 6.9 7.3 Dry Density (PCF) 126.3 127.0 126.0 Probe Depth am) 6 6 6 Proctor Lab No. Optimum Moisture (%) Max. Dry Density (PCF) SUMMARY OF RESULTS, Percent Field Compaction 98.6 99.2 98.4 Percent Compaction Requirement 95.0 95.0 95.0 Test Statw PASSEL PASSEL PASSEL Remarks: Proctor information provided by client. WINGERTER LABORATORIES, INC. offers no warrantee expressed or implied that material tested is representative of the proctor sample Optimum Moisture - 8.0% and Max. Dry Density=128.0(PCF). Field density test was performed in accordance with ASTM D 2922. This report is submitted es the confidential propaty of the client. The original of this report was signed and sealed by the hacm referenced Registered Engineer in accordance with Rule 61015 - 18.011 of Florida Admini trative Code. ,tttttIIIIittti it Z. *: No 44847 • Respertatlly submitted, % ; _ _ * WIIli88tTER LABORATORIES, INC. n j ,;.ini T \rte d J. Flood, 114 P.E. sWsiNA; 01orida License No. 44847