Loading...
RC-15-20FORM 405-10 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION •j Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2014-066 London Residence Street: 9290 North Bayshores Drive City, State, Zip: Miami Shores , FL , 33138- Owner: Ricki Lee London Design Location: FL, Miami Builder Name: Owner Permit Office: Miami Shore.. "•:' '" Permit Number:~ Jurisdiction: Miami Dade r+ aA U 3 1 1. New construction or existing = F 2. Single family or multiple family n 1i. ?� }• : at•;@+ .� 3. Number of units, if multiple family ,+ > ;""' �' 4. Number of Bedrooms ^• t,z 11-; "44 -y 5. Is this a worst case? N • = - ' /.'• " ? t, 'f+" 6. Conditioned floor area above grade (ft2) 3 .'` + 1�t ?• ra. i ` , Con :`honed floor area below grade (ft2) 0 fir: a 3 • l . ; 7. Windows(397.5 sqft.) Description a. U -Factor: Sgl, U=0.85 390.14 ft2 ,,. SHGC: SHGC=0.50 b. U -Factor: Sgl, U=0.70 7.33 ft2 SHGC: SHGC=0.50 '" c. U -Factor: N/A ft2 SHGC: d. U -Factor: N/A ft2 „y_ ' SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.500 8. Floor Types (3290.0 sqft.) Insulation Area a. Raised Floor R=3.0 2300.00 ft2 b. Slati-On-Grade Edge Insulation R=3.0 990.00 ft2 c. N/A R= ft2 9. Wall Types (1954.5 sqft.) ; _,_ ,_ .tib .a w-,/ .ncrete Block -Int Insul R=4.1 1853.30 ft2 b. Concrete Block -Int Insul, AdjacentR=4.1 101.25 ft2 , ,, N/A R= ft2 '� d.'N/AR=ft2 eiling Types (3290.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=30.0 • 3290.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 329 b. Sup: Attic, Ret: Attic, AH: Garage 6 329 12. Cooling systems kBtu/hr Efficiency a. Central Unit 48.0 SEER:17.70 b. Central Unit 36.0 SEER:19.40 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 34.1 COP:1.00 b. Electric Strip Heat 27.3 CO :1.00 14. Hot water systems a. Electric ap: 50 g Ions EF• .920 b. Conservation features None 15. Credits Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 65.73 PASS Total Standard Reference Loads: 92.87 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY • • Review of the plans and • .. • :.• X4.5 specifications covered by this • ... . ; .� calculation indicates compliance •••• b _ ii, �' with the Florida Energy Code. • • . F+ or. .. ,y Before construction is completed •`' • Sri pA .. • • -. p. ,.• • • ,..�,". ' ••• ,ti:, 6 • '' ""' �� • ,s • rs. ., ;.. :` .- • • •••11 DATE: O .. this building will be inspected for ...: compliance with Section 553.908 • ' *` Florida Statutes. �'"r `� : • • Op • • •• BUILDING OFFICIAL- • • • I herebycertifythat this budding,as designed, is in compliance with the Florida Energy Code. OWNER/AGENT- DATE' DATE -cu. • - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist +s 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 PROJECT ' Title: 2014-066 London Residence Bedrooms: 4 Building Type: User Conditioned Area: 3290 Owner: Ricki Lee London Total Stories: 1 # of Units: 1 Worst Case: No Builder Name: Owner Rotate Angle: 180 Permit Office: Miami Shores Cross Ventilation: Jurisdiction: Miami Dade Whole House Fan: Family Type: Single-family New/Existing: New (From Plans) Comment: Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street 9290 North Bayshores County: Miami -Dade City, State, Zip: Miami Shores , FL , 33138- CLIMATE V Design Location TMY SiteIECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL_AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Biock1 1665 14985 2 Block2 1625 14625 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated hr 1 Living Room 550 4950 No 1 2 Family Room 220 1980 No 1 3 Kitchen 390 3510 Yes 1 4 Bathroom 4 40 360 No 0 5 Bedroom 1 245 2205 No 1 6 Master Bedroom 495 4455 No 2 7 Dining Room 170 1530 No 2 8 Bonus Room 495 4455 No 1 9 Bedroom 3 330 2970 No 1 10 Bathroom 3 100 900 No 0 11 Laundry Room 80 720 No 0 12 Bedroom 4 175 1575 No 1 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 1 1 Yes Yes Yes 1 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes .. YQs Yes : 1 1 : .Ygs • ',is Ws•: • .. • . • • 0 1 ....Its : • • YCS .Y . ; • 0 1 ••••Yes Yes nets. . 1 1 • Yes • • •Yes+ Yes .... ..•. FLOORS I • •. • # Floor Type Space Perimeter Perimeter R -Value Joist RNdttp : Tile 'Wood Carpet. . Area_ 1 Raised Floor Living Room ___ ___ 550 ft2 3. • 06...:0 0.5 • • • . • • • 220 ft2 3 • Oe : • a 0..5 390 ft2 3 0.5 0 0.5 40 ft2 3 0.5 0 0.5 2 Raised Floor Family Room ___ ___ 3 Raised Floor Kitchen ____ M_ 4 Raised Floor Bathroom 4 ___ __ 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 ' FLOORS V # Floor Type Space Perimeter Perimeter R -Value Area Joist R -Value Tile Wood Carpet 5 Raised Floor Bedroom 1 ____ 6 Slab -On -Grade Edge Insulatio Master Bedroom 2 ft 7 Raised Floor Dining Room _ 8 Slab -On -Grade Edge Insulatio Bonus Room 2 ft 9 Raised Floor Bedroom 3 -__ 10Raised Floor Bathroom 3 _ 11Raised Floor Laundry Room _ 12Raised Floor Bedroom 4 ___ - 245 ft2 3 495 ft2 ____ 170 ft2 3 495 ft2 ___ 330 ft2 ___ 100 ft2 ___ 80 ft2 _ 175 ft2 3 0.5 0 __- 0.5 0 3 0.5 0 __ 0.5 0 3 0.5 0 3 0.5 0 3 0.5 0 3 0.5 0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1 ROOF V Roof # Type Materials Area Gable Roof Solar Area Color Absor. SA Emitt Emitt Deck Tested Tested Insul. Pitch (deg) 1 Hip Flat tile/slate 3467 ft2 0 ft2 Medium 0.96 No 0.9 No 30 18.4 h ATTIC • V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3290 ft2 N Y CEILING V# Ceiling Type Space R -Value Area Framing Frac Truss Type 1 Under Attic (Unvented) Living Room 2 Under Attic (Unvented) Family Room 3 Under Attic (Unvented) Kitchen 4 Under Attic (Unvented) Bathroom 4 5 Under Attic (Unvented) Bedroom 1 6 Under Attic (Unvented) Master Bedroom 7 Under Attic (Unvented) Dining Room 8 Under Attic (Unvented) Bonus Room 9 Under Attic (Unvented) Bedroom 3 10 Under Attic (Unvented) Bathroom 3 11 Under Attic (Unvented) Laundry Room 12 Under Attic (Unvented) Bedroom 4 2 550 ft2 2 220 ft2 2 390 ft2 2 40 ft2 2 245 ft2 2 495 ft2 2 170 ft2 2 495 ft2 2 330 ft2 2 100 ft2 2 80 ft2 2 175 ft2 0.11 Wood 0.11 Wood 0.11 Wood 0.11 Wood 0.11 • • • • •Vyaod 0.f1. • • : • Wood 0.1•1• • • •• •• •• Wood 0.161 •Wood •••• .••• 0.1'1, • • • • • • „Wdod 0.1.1 • • +uVood •• • 0.ff' ' • • • Wood • 0. • : • Vyood 'M • • • ' • : • • . • • • WALLS • • 1 • • • •• • • ••• • _ ' • 1 • Adjacent • •• • , • - Space N=>S Exterior Concrete Block - Int Insiiliving Room N=>S Exterior Concrete Block - Int Ins6Family Room E=>W Exterior Concrete Block - Int Insfalamily Room Width Height - - 4.1 6 6 9 4.1 21 2 9 4.1 9 9 9 Sheathing Framing Solar - _ - .- .,' • • • . • C -Grade% 58.5 ft2 0 0.5 190.5 ft2 0 0.5 87.8 ft2 0 0.5 Below 1 0 0 0 _ 2 3 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7 WALLS VAdjacent # Cavity Width Height Sheathing Framing Solar Omt To Wall Type Space R. - - - .- •«I . •• • . •. Below .- . - o 4 E=>W Exterior Concrete Block - Int Insul Kitchen 4.1 16 7 9 149.3 ft2 0 0.5 0 5 N=>S Exterior Concrete Block - Int InsuBedroom 1 4.1 7 2 9 64.5 ft2 0 0.5 0 6 E=>W Exterior Concrete Block - Int InsuBedroom 1 4.1 23 3 9 209.3 ft2 0 0.5 0 7 S=>N Exterior Concrete Block - Int InsuBedroom 1 4.1 6 4 9 57.0 ft2 0 0.5 0 8 S=>N Exterior Concrete Block - Int Insblaster Bedro 4.1 27 1 9 243.8 ft2 0 0.5 0 9 N=>S Exterior Concrete Block - Int InsOining Room 4.1 11 3 9 101.3 ft2 0 0.5 0 10 S=>N Exterior Concrete Block - Int Ins®onus Room 4.1 23 4 9 210.0 ft2 0 0.5 0 11 S=>N Exterior Concrete Block - Int InsuBedroom 3 4.1 15 2 9 136.5 ft2 0 0.5 0 12 W=>E Exterior Concrete Blodc - Int InsuBedroom 3 4.1 20 4 9 183.0 ft2 0 0.5 0 13 W=>E Exterior Concrete Block - Int Insi.Bathroom 3 4.1 4 6 9 40.5 ft2 0 0.5 0 14 N=>S Exterior Concrete Block - Int InsuBedroom 4 4.1 13 6 9 121.5 ft2 0 0.5 0 15 W=>E Garage Concrete Block - Int Insdilaundry Roo 4.1 11 3 9 101.3 ft2 0 0.5 0 DOORS V # Omt Door Type Space Storms U -Value Ft width In Height Area 1 N=>S Wood Living Room None .46 5 4 7 37.3 ft2 2 E=>W Wood Family Room None .46 5 4 7 37.3 ft2 3 E=>W Wood Kitchen None .46 5 4 7 37.3 ft2 4 S=>N Wood Master Bedro None .46 3 7 21 ft2 • 5 S=>N Wood Master Bedro None .46 3 7 21 ft2 6 S=>N Wood Bonus Room None .46 4 8 7 32.7 ft2 7 W=>E Wood Laundry Roo None .46 2 10 7 19.8 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to As Built (rotated 180 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 1 N=>S 2 Metal Single (Clear) Yes 0.85 0.5 80.2 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 2 E=>W 3 Metal Single (Clear) Yes 0.85 0.5 25.1 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds 3 E=>W 4 Metal Single (Clear) Yes 0.85 0.5 25.1 ft2 0 ft 0 in 0: 0 in• Drapf' I E 4 E=>W 6 Metal Single (Clear) Yes 0.85 0.5 31.9 ft2 0 ft 0 in Olin : Drapes/blinds None lton„, None • • • 5 E=>W 6 Metal Single (Clear) Yes 0.85 0.5 4.1 ft2 0 ft 0 in 0TtATir• • Drapfls/blinds Nb?ifl"' 6 S=>N 7 Metal Single (Clear) Yes 0.85 0.5 6.0 ft2 0 ft 0 in 0lt•O'in' • Drapes/bhnds •••• •••• None • • • 7 N=>S 9 Metal Single (Clear) Yes 0.85 0.5 34.0 ft2 0 ft 0 in 01tAip •' Draplsaljiglg Npps. • 8 S=>N 10 Metal Single (Clear) Yes 0.85 0.5 40.8 ft2 0 ft 0 in 0 00:in •: Drapr'bl� di 9 S=>N 10 Metal Single (Clear) Yes 0.85 0.5 35.6 ft2 0 ft 0 in 01tb iii' Drapes/6Iinds *AA • • tfone .:1 •••••• • 10 S=>N 11 Metal Single (Clear) Yes 0.85 0.5 29.6 ft2 0 ft 0 in 0 (•t 0 iA : Drapgs/blinQs • lypgt,: 11 W=>E 12 Metal Single (Clear) Yes 0.85 0.5 14.8 ft2 0 ft 0 in 0 ft 0 in • Drapis/bl nds None 12 W=>E 12 Metal Single (Clear) Yes 0.85 0.5 10.3 112 0 ft 0 in 0 fttrin • Draprs'bIVIC Nbne 13 W=>E 13 Metal Single (Clear) Yes 0.85 0.5 18.8 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 14 N=>S 14 Metal Single (Clear) Yes 0.85 0.5 34.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 15 W=>E Skylt Metal Single (Clear) Yes 0.7 0.5 7.3 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7 8/20/2014 10:04 PM •••. • • • • .••• •••• • ...• . . .. •• .••• • • • •• • • • • • • • • • • • • .• • . . .• • ••• • • • • • EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 GARAGE V# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 515 ft2 515 ft2 58 ft 9 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 4314.9 236.88 445.49 .345 8.7434 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat 2 Electric Strip Heat None None COP: 1 34.13 kBtu/hr 1 COP: 1 27.3 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit 2 Central Unit Split Split SEER: 17.7 48 kBtu/hr 1440 cfm 0.75 1 SEER: 19.4 36 kBtu/hr 1080 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM V# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 70 gal 120 deg None i SOLAR HOT WATER SYSTEM VFSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — # Location R -Value Area -- Retum — Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN • j1j..F Heat Cool • 1 Attic 6 329 ft2 2 Attic 6 329 ft2 Attic Attic 82.25 ft Default Leakage Garage (Default) (Default • : •• • • 82.25 ft Default Leakage Garage (Default) {Defpwlta • 1 • gl e . 2 • • %• ; 8/20/2014 10:04 PM •••. • • • • .••• •••• • ...• . . .. •• .••• • • • •• • • • • • • • • • • • • .• • . . .• • ••• • • • • • EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 • • . • •• • • •••• • . • • •• • • • • • •.•• •••• • • • • •••• •••• • • •• •• • • • • • • • • • • •• • •••• • • • • • • • • • • • ••• • • • • • .• • • • • • 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun X Jul X Aug X Sep Oct NovDec Heating X Jan Jan X) Feb Feb X Mar X Mar Apr X Apr t May [ MayJunJulAugSep Jun Jul Aug Sep Oct X Oct Nov i))1 Nov X DecVenting Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 ' 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 • • . • •• • • •••• • . • • •• • • • • • •.•• •••• • • • • •••• •••• • • •• •• • • • • • • • • • • •• • •••• • • • • • • • • • • • ••• • • • • • .• • • • • • 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 9290 North Bayshores Drive Miami Shores, FL, 33138 - PERMIT #: MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. / Thermostat & controls 403.1 At least one thermostat shall be provided for each separate heating and cooling system. Where forced -air fumace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the Toad. / Ducts 403.2.2 403.3.3 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical ventilation 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. •••• No make-up air from attics, crawlspaces, garages or outdoors adjacent...' to pools or spas. • • • • •..... 4.. - Swimming Pools & Spas 403.9 • Pool pumps and pool pump motors with a total horsepower4-4R) of = 1 . HP shall have the capability of operating at two or more speed l. Spa: • • • and heated pools must have vapor -retardant covers or a Itquid cover or• • other means proven to reduce heat loss except if 70% of feat from . • •:• site -recovered energy. Off/timer switch required. Gas hettetteminimurti• thermal efficiency=78% (82% after 4/16/13). Heat pumpWcD staters - minimum COP= 4.0. • • • • • • . • • •• •(- k... . • • • • • • • . - ••• Cooling/heating equipment 403.6 Sizing calculation performed & attached. Minimum efficieneies•per • • • •• Tables 503.2.3. Equipment efficiency verification required. Special • • occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. . • • • • Ceilings/knee walls 405.2.1 R-19 space permitting. 8/20/2014 10:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7 ••• • • ••- • .•- • • - .•- • • • • • - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 71 The lower the EnergyPerformance Index, the more efficient the home. 9290 North Bayshores Drive, Miami Shores, FL, 33138- 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U -Factor: Sgl, U=0.85 SHGC: SHGC=0.50 b. U -Factor: SgI, U=0.70 SHGC: SHGC=0.50 c. U -Factor: N/A SHGC: d. U -Factor: N/A SHGC: • Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Raised Floor b. Slab -On -Grade Edge Insulation c. N/A New (From Plans) Single-family 1 4 No 3290 Area 390.14 ft2 7.33 ft2 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Concrete Block - Int Insul, Adjacent c. N/A d. N/A 10. Ceiling Types a. Roof Deck (Unvented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage b. Sup: Attic, Ret: Attic, AR: Garage 12. Cooling systems ft2 a. Central Unit b. Central Unit ft2 0.000 ft. 0.500 Insulation Area R=3.0 2300.00 ft2 R=3.0 990.00 ft2 R= ft2 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: • • • •. .•.. • ••• • .•• ... Insulation R=4.1 R=4.1 R= R= Insulation R=30.0 R= R= Area 1853.30 ft2 101.25 ft2 ft2 ft2 Area 3290.00 ft2 ft2 ft2 R ft2 6 329 6 329 kBtu/hr Efficiency 48.0 SEER:17.70 36.0 SEER:19.40 kBtu/hr Efficiency 34.1 COP:1.00 27.3 COP:1.00 Cap: 50 gallons EF: 0.92 Pstat • . • *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualjry f9l.gnergyeiclent • mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the Energyasuge Hotlipe 4.121) • 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. Por information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software • • • • • Building Input Summary Report PROJECT Title: 2014-066 London Residence Bedrooms: 4 Address Type: Street Address Building Type: User Bathrooms: 0 Lot # Owner: Ricki Lee London Conditioned Area: 3290 sq.ft. Block/SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Owner Worst Case: No Street: 9290 North Bayshores Permit Office: Miami Shores Rotate Angle: 180 County: Miami -Dade Jurisdiction: Miami Dade Cross Ventilation: City, State, Zip: Miami Shores , Family Type: Single-family Whole House Fan: FL , 33138- New/Existing: New (From Plans) Terrain: Suburban Year Construct: 2014 Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 Low UTILITY RATES Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 0 0.1151 Natural Gas Therm Florida Average 0 1.72 . Fuel Oil Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft ...• Oft SW None Oft Oft Oft Oft• • Oft'•...' Off..,,, W None Oft Oft Oft Oft•••• : Oft. . Oft • • NW None Oft Oft Oft Oft Oft. Off. • BLOCKS _ •... Number Name Area Volume • •-•_•-• • • •' '• • •••••• 1 Blockl 1665 14985, • 2 Block2 1625 14625 • • . • ' • SPACES• • •• i • .• . . •• - 1 Number Name Area Volume Kitchen Occupants Bedrooms Finished Ooeled • Heated 1 Living Room 550 4950 No 1 Yes Yes Yes 2 Family Room 220 1980 No 1 0 Yes Yes Yes 3 Kitchen 390 3510 Yes 1 0 Yes Yes Yes 4 Bathroom 4 40 360 No 0 0 Yes Yes Yes 5 Bedroom 1 245 2205 No 1 1 Yes Yes Yes 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 1 of 7 6 Master Bedroom 495 4455 No 2 1 Yes Yes Yes Building Input Summary Report 8/20/2014 10:05 PM EnergyGauge®/ USRFSB v3.1 Page 2 of 7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 7 Dining Room 170 1530 No 2 0 Yes Yes Yes 8 Bonus Room 495 4455 No 1 0 Yes Yes Yes 9 Bedroom 3 330 2970 No 1 1 Yes Yes Yes 10 Bathroom 3 100 900 No 0 0 Yes Yes Yes 11 Laundry Room 80 720 No 0 0 Yes Yes Yes 12 Bedroom 4 175 1575 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R -Value Area Joist R -Value Tile Wood Carpet 1 Raised Floor Living Room ____ __ 550 ft2 3 0.5 0 0.5 2 Raised Floor Family Room ____ ___ 220 ft2 3 0.5 0 0.5 3 Raised Floor Kitchen ___ ___ 390 ft2 3 0.5 0 0.5 4 Raised Floor Bathroom 4 ____ ___ 40 ft2 3 0.5 0 0.5 j 5 Raised Floor Bedroom 1 ____ f_ 245 ft2 3 0.5 0 0.5 . 6 Slab -On -Grade Edge Insulation Master Bedroom 2 ft 3 495 ft2 ____ 0.5 0 0.5 7 Raised Floor Dining Room ____ __ 170 ft2 3 0.5 0 0.5 8 Slab -On -Grade Edge Insulation Bonus Room 2 ft 3 495 ft2 _- 0.5 0 0.5 9 Raised Floor Bedroom 3 _— -- 330 ft2 3 0.5 0 0.5 10 Raised Floor Bathroom 3 ___ ____ 100 ft2 3 0.5 0 0.5 11 Raised Floor Laundry Room ___- ___ 80 ft2 3 0.5 0 0.5 12 Raised Floor Bedroom 4 ____ __ 175 ft2 3 0.5•••••0 0.5 ROOF •• • •- • • •• Roof Gable Roof Solar SA ••Mitt Emitt • Deck .U. # Type Materials Area Area Color Absor. Tested"". •Ilea Te t16 • jnsul. •(deg) 1 •••• ••••.- 1 Hip Flat tile/slate 3467 ft2 0 ft2 Medium 0.96 No. • •••69 N9.,. 30 .1$.¢e' ATTIC ••'••" '••' • • �• - . •# Type Ventilation Vent Ratio (1 in) Area RBS : IgC•C • • • 1 Full attic Unvented 0 3290 ft2 N •+—• Y . •.• •_ • •• • . 8/20/2014 10:05 PM EnergyGauge®/ USRFSB v3.1 Page 2 of 7 Building Input Summary Report 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 3 of 7 CEILING # Ceiling Type Space R -Value Area Framing Fraction Truss Type 1 Under Attic () Living Room 2 550 ft2 0.11 Wood 2 Under Attic 0 Family Room 2 220 ft2 0.11 Wood 3 Under Attic 0 Kitchen 2 390 ft2 0.11 Wood 4 Under Attic () Bathroom 4 2 40 ft2 0.11 Wood 5 Under Attic () Bedroom 1 2 245 ft2 0.11 Wood 6 Under Attic () Master Bedroom 2 495 ft2 0.11 Wood 7 Under Attic () Dining Room 2 170 ft2 0.11 Wood 8 Under Attic 0 Bonus Room 2 495 ft2 0.11 Wood 9 Under Attic () Bedroom 3 2 330 ft2 0.11 Wood 10 Under Attic () Bathroom 3 2 100 ft2 0.11 Wood 11 Under Attic () Laundry Room 2 80 ft2 0.11 Wood 12 Under Attic 0 Bedroom 4 2 175 ft2 0.11 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. # AdjTacent ty Omt o Wall Type Space R-CaviValue Width Heig Ft In Ft nht Area Sheathing Framing Solar Below R -Value Fraction Absor. Grade% 1 N=>S Exterior Concrete Block - Int Insul Living Room 4.1 6 6 9 58.5 ft2 0 0.5 0 2 N=>S Exterior Concrete Block - Int Insul Family Room 4.1 21 2 9 190.5 ft2 0 0.5 0 3 E=>W Exterior Concrete Block - Int Insul Family Room 4.1 9 9 9 87.8 ft2 0 0.5 0 4 E=>W Exterior Concrete Block - Int Insul Kitchen 4.1 16 7 9 149.3 ft2 0 0.5 0 5 N=>S Exterior Concrete Block - Int Insul Bedroom 1 4.1 7 2 9 64.5 ft2 0 0.5 0 6 E=>W Exterior Concrete Block - Int Insul Bedroom 1 4.1 23 3 9 209.3 ft2 0 0.5 0 7 S=>N Exterior Concrete Block - Int Insul Bedroom 1 4.1 6 4 9 57.0 ft2 0 0.5 0 8 S=>N Exterior Concrete Block - Int InsuMaster Bedroo 4.1 27 1 9 243.8 ft2 0 0.5 0 9 N=>S Exterior Concrete Block - Int Insul Dining Room 4.1 11 3 9 101.3 ft2 0 0.5 0 10 S=>N Exterior Concrete Block - Int Insul Bonus Room 4.1 23 4 9 210.0 ft2 0 0.5 0 11 S=>N Exterior Concrete Block - Int Insul Bedroom 3 4.1 15 2 9 136.5 ft2 0 •••••0,5 0 12 W=>E Exterior Concrete Block - Int Insul Bedroom 3 4.1 20 4 9 183.0 ft2 • ••• 0 ••••0.5 • • u • •• . • •• 13 W=>E Exterior Concrete Block - Int Insul Bathroom 3 4.1 4 6 9 40.5 ft2 0 :••••01.5 ••p•; 14 N=>S Exterior Concrete Block - Int Insul Bedroom 4 4.1 13 6 9 121.5 ft2 0 • 0.5 • 0 15 W=>E Garage Concrete Block - Int InsuLaundry Room 4.1 11 3 9 101.3 ft2 •••••• 0 . • • • •Q5 • 0 •... ...• DOORS• • • • • . • .. .. •.• Width• • • • Height • • # Omt Door Type Space Storms U -Value Ft . In : Ft . In. Ares...: 1 N=>S Wood Living Room None .46 5 : . • • 7 • 37.3 ft2 2 E=>W Wood Family Room None .46 5 • •4 • 7 • • : •: 37.31t2 •. • 3 E=>W Wood Kitchen None .46 5 4 7 37.3 ft2 4 S=>N Wood Master Bedroo None .46 3 7 21 ft2 5 S=>N Wood Master Bedroo None .46 3 7 21 ft2 6 S=>N Wood Bonus Room None .46 4 8 7 32.7 ft2 7 W=>E Wood Laundry Room None .46 2 10 7 19.8 ft2 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 3 of 7 Building Input Summary Report 8/20/2014 10:05 PM EnergyGauge®/ USRFSB v3.1 Page 4 of 7 WINDOWS Wall Overhang # Omt ID Frame Panes NFRC U -Factor SHGC Storm Area Depth Separation Interior Shade Screening 1 N=>S 2 Metal Single (Clear) Yes 0.85 0.5 N 80.2 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 2 E=>W 3 Metal Single (Clear) Yes 0.85 0.5 N 25.1 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 3 E=>W 4 Metal Single (Clear) Yes 0.85 0.5 N 25.1 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 4 E=>W 6 Metal Single (Clear) Yes 0.85 0.5 N 31.9 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 5 E=>W 6 Metal Single (Clear) Yes 0.85 0.5 N 4.1 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 6 S=>N 7 Metal Single (Clear) Yes 0.85 0.5 N 6.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 7 N=>S 9 Metal Single (Clear) Yes 0.85 0.5 N 34.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 8 S=>N 10 Metal Single (Clear) Yes 0.85 0.5 N 40.8 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 9 S=>N 10 Metal Single (Clear) Yes 0.85 0.5 N 35.6 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 10 S=>N 11 Metal Single (Clear) Yes 0.85 0.5 N 29.6 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 11 W=>E 12 Metal Single (Clear) Yes 0.85 0.5 N 14.8 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 12 W=>E 12 Metal Single (Clear) Yes 0.85 0.5 N 10.3 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 13 W=>E 13 Metal Single (Clear) Yes 0.85 0.5 N 18.8 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 14 N=>S 14 Metal Single (Clear) Yes 0.85 0.5 N 34.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 15 W=>E Skylt Metal Single (Clear) Yes 0.7 0.5 N 7.3 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 Space(s) 1 Wholehouse Best Guess .0005 4314.9 236.88 445.49 .345 8.7434 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 515 ft2 515 ft2 58 ft 9 ft (invalid) MASS Mass Type Area Thickness Fumiture Fraction Space No Added Mass 0 ft2 •••••• 0 ft 0.3 : j.Rrjng Room.... . •• • • • • No Added Mass 0 ft2 0 ft 0.3 • • • •Ftrrily Roos» • • • • • No Added Mass 0 ft2 0 ft 0.3 • Kitchen . • No Added Mass 0 ft2 Oft 0.3 ••••Bhroom•4••••• • No Added Mass 0ft2 Oft 0.3 •••Bedroom1•••• • •••• No Added Mass 0 ft2 0 ft 0.3 ... MMst'tr Bedragry • : No Added Mass 0 ft2 0 ft 0.3 • • • •4Hning Room • • • • No Added Mass 0 ft2 0 ft 0.3 • Bonus Roc'h . •:. ' • • • • No Added Mass 0 ft2 Oft 0.3 ••••Bldroom3• .•• • No Added Mass 0 ft2 0 ft 0.3 Bathroomq3. • • No Added Mass 0 ft2 0 ft 0.3 Laundry Room No Added Mass 0 ft2 0 ft 0.3 Bedroom 4 8/20/2014 10:05 PM EnergyGauge®/ USRFSB v3.1 Page 4 of 7 Building Input Summary Report HEATING SYSTEM # System Type Subtype Efficiency Capacity HeatPump Ducts Block —Geothermal Entry Power Volt. Curr 1 Electric Strip Heat None COP:1 34.13 kBtu/hr 0 0 0 sys#1 1 2 Electric Strip Heat None COP:1 27.3 kBtu/hr 0 0 0 sys#2 2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ducts Block 1 Central Unit Split SEER:17.7 48 kBtu/hr 1440 cfm 0.75 sys#1 1 2 Central Unit Split SEER:19.4 36 kBtu/hr 1080 cfm 0.75 sys#2 2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Credits 1 Electric None Garage 0.92 50 gal 70 gal 120 deg None SOLAR HOT WATER Collector Surface Absorp. Trans Tank Tank Tank Heat PV Pump Collector Type Tilt Azimuth Area Loss Coef. Prod. Corr. Volume U -Value Surf Area Exch Eff Pumped Energy DUCTS DUCT Supply Retum Air CFM 25 CFM25 HVAC # # Location R -Value Area Location Area Number Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 329 ft2 Attic 82.25 ft2 1 Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 329 ft2 Attic 82.25 ft2 1 Default Leakage Garage (Default) (Default) 2 2 TEMPERATURES Programable Cooling Heating Venting Thermostat: Jan X Jan Jan Y Feb X7 Feb Feb Mar X Mar 'X Mar Ceiling Apr Apr X Apr Fans: May May May N X] Jun ; ]Jun 1 Jun X Jul Jul Jul X Aug Aug Aug X Reel?) Sep Oct Oct X Oct Nov Nov Nov Dec X Dec Dec Thermostat Schedule: HERS 2006 Reference Hours "" • Schedule Type 1 2 3 4 5 6 7 8 :9 .'. 10 "''M 12";' .. . . • Cooling (WD) AM 80 78 78 78 78 78 78 78 4080 : • • .b. 78 $8 • •:4 . • Cooling (WEH) AM 78 78 78 78 78 78 78 78 Z$.• 78 ...78 78"", PM 78 78 78 78 78 78 78 78 •78 • 78 • 78. 78 .••. ..•. Heating (WD) AM�g sg• 1 66 66 68 66 66 66 68 68 68 •68.' • 68 ..' •6�6. B8"' • • . • .. • I Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68•68 • PM 68 68 68 68 68 68 68 68 .68. • 68 '66 66 '. • • • . •• • 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 • • •.• • • . • . Page 5 of 7 • Building Input Summary Report ' APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.046 0.046 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 3087 kWh/Yr Peak Value: 1008 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 ,Annual Use: 0 kWh/Yr Peak Value: 0 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 • Annual Use: 0 kWh/Yr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 140 Watts Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 0.1 0.1 % Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts REFRIGERATORS." ' ' • • .... 4 ID Type Screen Location Quantity Vol FrZ. Vol Make MBdei ' Schhgiilt:, kWhPerWL 1 Refrigerat Default New Kitchen 1 25.6 5 • HERS20a 691 CLOTHES WASHERS •"��• •••• •••• ID Type Screen Location Capacity Make Model • Ichedule' :tpadsPefrr • ' 1 1 Main Default New Main 2.847 • • • • IDIERS201 ••• • (invalid) •' . • • CLOTHES DRYERS • • • • . ID Type Screen Location Capacity Fuel Type Make 1 Model " Schedule • LcadsPe7Yr ' 1 Dryers Default New Main Electricity 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 6 of 7 Building Input Summary Report •• • . • • •••• • • • • •• • • • • • • • • •••• •••• • • • • •••• •••• • • •• •• •••• • • • • • • • • • • • • • • • • • • • •• • • • • •• • • • • ••• • • • • • 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 7 of 7 DISHWASHERS ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr 1 Dishwash Default New Main 12 2004 or N HERS201 372 RANGE OVEN ID Type Screen Location Type Fueltype Make Model Cooktop Oven 1 Ranges Default New Main CooktopOven C Electric Electric FI Not Cony MISC ELECTRICAL LOADS ID Type Screen Item Quantity Catagory Operating Location Schedule Off Standby 1 Misc Elec Simple Default 1 1 Main HERS201 1 •• • . • • •••• • • • • •• • • • • • • • • •••• •••• • • • • •••• •••• • • •• •• •••• • • • • • • • • • • • • • • • • • • • •• • • • • •• • • • • ••• • • • • • 8/20/2014 10:05 PM EnergyGauge® / USRFSB v3.1 Page 7 of 7 08/20/201z 10:07PM Project Name: 2014-066 London residence Prepared by: Whitelocke & Williams Air System Sizing Summary for AHU-1 Air System Information Air System Name AHU-1 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Number of zones 1 Floor Area 1665.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.8 Tons Load occurs at Oct 1500 Total coil load 33.7 MBH OA DB / WB 87.0 / 75.0 °F Sensible coil load 32.5 MBH Entering DB / WB 75.2 / 63.2 °F Coil CFM at Oct 1500 1717 CFM Leaving DB / WB 57.7 / 56.6 °F Max block CFM 1717 CFM Coil ADP 55.8 °F Sum of peak zone CFM 1717 CFM Bypass Factor 0.100 Sensible heat ratio 0.963 Resulting RH 52 % ft2/Ton 592.9 Design supply temp. 55.0 °F BTU/(hr-ft2) 20.2 Zone T -stat Check 1 of 1 OK Water flow © 10.0 °F rise N/A Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data ' Max coil load 13.1 MBH Load occurs at Des Htg Coil CFM at Des Htg 1717 CFM BTU/(hr-ft2) 7.9 Max coil CFM 1717 CFM Ent. DB / Lvg DB 70.1 / 77.1 °F Water flow © 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1717 CFM Fan motor BHP 0.24 BHP Standard CFM 1716 CFM Fan motor kW 0.19 kW Actual max CFM/ft2 1.03 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person 0.00 CFM/person CFM/ft2 0.00 CFM/ft2 • ..• • • • • ••.• • • • . .. • • • .• •• ••• • • • • • •••• •••• • • • • • • •••• •••• • • •• •• •••• • • • •• • • • • • . • • • • • • • • • • • •• • ')Ar/c • • • • ••• • • • • • Hourly Analysis Program v4.80 Page 1 of 2 Project Name: 2014-066 London residence Prepared by: Whitelocke & Williams Air System Sizing Summary for AHU-2 08/20/201i 10:07PN Air System Information Air System Name AHU-2 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Number of zones 1 Floor Area 1625.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.5 Tons Load occurs at Jun 1600 Total coil load 29.6 MBH OA DB / WB 89.7 / 76.9 °F Sensible coil load 27.9 MBH Entering DB / WB 75.0 / 62.6 °F Coil CFM at Jun 1600 1392 CFM Leaving DB / WB 56.5 / 55.3 °F Max block CFM 1392 CFM Coil ADP 54.4 °F Sum of peak zone CFM 1392 CFM Bypass Factor 0.100 Sensible heat ratio 0.944 Resulting RH 50 % ft2/Ton 659.5 Design supply temp. 55.0 °F BTU/(hr-ft2) 18.2 Zone T -stat Check 1 of 1 OK Water flow © 10.0 °F rise N/A Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 12.8 MBH Load occurs at Des Htg Coil CFM at Des Htg 1392 CFM BTU/(hr-ft2) 7.9 Max coil CFM 1392 CFM Ent. DB / Lvg DB 70.2 / 78.7 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1392 CFM Fan motor BHP 0.19 BHP Standard CFM 1392 CFM Fan motor kW 0.15 kW Actual max CFM/ft2 0.86 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person 0.00 CFM/person CFM/ft2 0.00 CFM/ft2 ••.• • • • • •••• • • • • •• • • • • • • • • • • •••• •••• • • • • • • •••• •••• •.y.. •••• • • • . • •• ••• .• • • • • • • • . • • • • • • • • • • •• • • ••• • • • • • •• . c-- 07/4/ Hourly Analysis Program v4.80 Page 2 of 2