In accordance with your authorization, Federal Engineering & Testing, Inc. has performed Tile Uplift Testing in
compliance with Testing Application Standards TAS -106 and the Florida Building Code High Velocity Hurricane Zone on
November 22, 2017 at the above referenced project. The purpose of our inspection was to determine the uplift capacity
of the roof tiles for the residence at the above referenced project.
The subject roof consisted of S -Shaped Concrete Tile Foam Set. The pitch of the subject roof is 4/12. Our field engineer
visited the site and conducted 3 uplift tests on the roof tiles. All tests were performed according to the Florida Building
Code High Velocity Hurricane Zone and protocol TAS -106 using an Intercomp Scale Model CS200. The following is a
summary of results:
Field Test Results
Test Number
Test Location
Field Uplift Pull Test
Test Results
N/A Corner
See Attached Diagram
35 ± 5 Pounds
N/A
1 Perimeter
See Attached Diagram
35 ± 5 Pounds
Passed
2 Field
See Attached Diagram
35 ± 5 Pounds
Passed
3 Hip/ Ridge
See Attached Diagram
35 ± 5 Pounds
Passed
All test results were found to be in compliance with TAS -106 and the Florida Building Code
The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our
attention for remedial work. This uplift test is not a roof top inspection. A final roof inspection must be conducted by the
building official for approval. The test results presented reflect the condition of the roof system at the time of the test.
These results are time and sample dependent since roof conditions are continuously changing due to exposure to the
elements. Federal Engineering & Testing, Inc. is an independent third party providing un -biased testing information and
results and is not affiliated with our client nor do we have any financial interest in the project or determination of the test
results. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property
of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is
reserved pending our written approval.
We aosreciate^the. dp►iortunity to be of service to you at this phase of your project. If you have any questions or
coml3W4,..pleasg6194:11.5 a call. It has been a pleasure working with you and look forward to doing so again in the
n°eerffutt?re.
.S:ic§r:ly, rsI w :':
Y t
•% i 'lire j �� ��� -�Ir" .�
Keith LeBlanc, P:E. 7. !'-Zy_1�
.� r •
Federal E,ngcneering &Jesting, Inc.
Florid:E2dg. No. 59394 t‘` �~
Certificateoi 7;uthdrizatioh # 5471
Miami -Dade County Certification # 16-0203.07
Construction Material
Engineering Council
American Concrete
Institute
MIAMFDADE
COUNTY
Miami Dade Florida Department
County of Transportation
1
L Elta4mi
f - k- ,
at*
—.4 -f
a= 0.1(w)= 0.1( 40 ') = 4.0 '
a= 0.4 (h)= 0.4( 15 ') = 6.0'
Perimeter Dimensions : 4.0 '
Figure R301.2(7) Componet & Cladding Pressure Zones
Corner Area: N/A S.F. = N/A tests
Perimeter Area: 32 S.F. = 1 tests
Field Area: 68 S.F. = 1 tests
Ridge Caps: 2 = 1 tests
Total Tests Performed: = 3
*All dimensions are approximate*
Test Location Sketch
ENGINEERING
Q
N
Federal Engineering & Testing Inc. 250 SW 13th AVE Pompano Beach, FL 33069 (954) 784-2941
Client: Paul Bange Roofing
Test: TAS -106 Tile Uplift Test
(Test location sketch is not to scale)
Project: Proposed Roof: Bach Residence
Project Address: 9304 NE 5th Avenue
Miami Shores, FL 33138
J