RF-17-2007 (2)FLORIDA INTERNATIONAL
ENGINEERING & TESTING LAB
INSIGIIT • INNOb A T ION • IN 11 GRAT ION
;FLORIDA INTERNATIONAL ENGINEERING AND TESTING LAB LLC
f' 6175 NW 167'" Street, Suite G-20, Miami, Florida 33015
Telephone: (305) 378-1991 - Fax: (305) 378-1997
Miami -Dade Lab Certification # 07-0612.11- State of Florida CA # 27273
SITE SPECIFIC INFORMATION V, -"D°
7
Job Address: 45 NE 98 Street, Miami Shores, FL 33138
Contractor: Hammock General Construction
Type of Tile: Concrete Tile
Permit # 17-2007 Test Date: Oct 3, 2017
Approx. Height 10' Floor: 1
Type of Access: Scaffolds: Ladder: OK Slope: 4:12
App. Sq.Ft: 1,900 Sq. ft Req. Force: 35 lbs Testing Equipment: F.G.E. 500H X, Shimpo Instrument
Dear Sir/Madam:
As per your request and authorization, representatives of Florida International Engineering and Testing Lab., Inc performed the
static load test on the roofing tile at the above referenced project. The purpose of this testing was to verify whether the installed tile
roofing system is capable of resisting the applied test load of 35 pounds uplift force. This testing was performed in general
accordance with Miami Dade Building Code Protocol PA 106. The static load was applied utilizing a calibrated scale and force
measuring instrument (dynamometer). A hook which is connected to the loading instrument was placed under the exposed edge of
the tile. Test load of 45 pounds force (lbf) was applied and also held for more than 5 second at each test location. The total load
applied on each test location was recorded. In addition to the static load test, the tested tile was also visually inspected for any kind
of adhesion failure after completion of each test.
No.
Result
No.
Result
No.
Result
No.
Result
No.
Result
No.
Result
No.
Result
1
Pass
21
Pass
41
Pass
61
81
101
121
2
Pass
22
Pass
42
Pass
62
82
102
122
3
Pass
23
Pass
43
Pass
63
83
103
123
4
Pass
24
Pass
44
Pass
64
84
104
124
5
Pass
25
Pass
45
Pass
65
85
105
125
6
Pass
26
Pass
46
66
86
106
126
7
Pass
27
Pass
47
67
87
107
127
8
Pass
28
Pass
48
68
88
108
128
9
Pass
29
Pass
49
69
89
109
129
10
Pass
30
Pass
50
70
90
110
130
11
Pass
31
Pass
51
71
91
111
131
12
Pass
32
Pass
52
72
92
112
132
13
Pass
33
Pass
53
73
93
113
133
14
Pass
34
Pass
54
74
94
114
134
15
Pass
35
Pass
55
75
95
115
135
16
Pass
36
Pass
56
76
96
116
136
17
Pass
37
Pass
57
77
97
117
137
18
Pass
38
Pass
58
78
98
118
138
19
Pass
39
Pass
59
79
99
119
139
20
Pass
40
Pass
60
80
100
120
140
111111111/
Based onoingAew elude that the installed roofing tile at the above referenced project is capable to resist the applied test
load. *v Qre;Ng [gticjitde, ti1�t if meets the Miami Dade Building Code Compliance Protocol TAS 106. Attached is the roof plan
shot �ipprq imate, test 1pcatip
Re'sg atfull�Su$nhit ed . 7.
:* ..:_„.
\.y'vTATF OF : 1-vsZ: 10.4.2017
V n yyagar,M.,Balakrishnan y; kt 4 e
Statf/d rittg Cdr# $A1O7. 0.\ `•
e''ei8 /0 M:‘%00
N `�`