Loading...
RF-17-2007 (2)FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB INSIGIIT • INNOb A T ION • IN 11 GRAT ION ;FLORIDA INTERNATIONAL ENGINEERING AND TESTING LAB LLC f' 6175 NW 167'" Street, Suite G-20, Miami, Florida 33015 Telephone: (305) 378-1991 - Fax: (305) 378-1997 Miami -Dade Lab Certification # 07-0612.11- State of Florida CA # 27273 SITE SPECIFIC INFORMATION V, -"D° 7 Job Address: 45 NE 98 Street, Miami Shores, FL 33138 Contractor: Hammock General Construction Type of Tile: Concrete Tile Permit # 17-2007 Test Date: Oct 3, 2017 Approx. Height 10' Floor: 1 Type of Access: Scaffolds: Ladder: OK Slope: 4:12 App. Sq.Ft: 1,900 Sq. ft Req. Force: 35 lbs Testing Equipment: F.G.E. 500H X, Shimpo Instrument Dear Sir/Madam: As per your request and authorization, representatives of Florida International Engineering and Testing Lab., Inc performed the static load test on the roofing tile at the above referenced project. The purpose of this testing was to verify whether the installed tile roofing system is capable of resisting the applied test load of 35 pounds uplift force. This testing was performed in general accordance with Miami Dade Building Code Protocol PA 106. The static load was applied utilizing a calibrated scale and force measuring instrument (dynamometer). A hook which is connected to the loading instrument was placed under the exposed edge of the tile. Test load of 45 pounds force (lbf) was applied and also held for more than 5 second at each test location. The total load applied on each test location was recorded. In addition to the static load test, the tested tile was also visually inspected for any kind of adhesion failure after completion of each test. No. Result No. Result No. Result No. Result No. Result No. Result No. Result 1 Pass 21 Pass 41 Pass 61 81 101 121 2 Pass 22 Pass 42 Pass 62 82 102 122 3 Pass 23 Pass 43 Pass 63 83 103 123 4 Pass 24 Pass 44 Pass 64 84 104 124 5 Pass 25 Pass 45 Pass 65 85 105 125 6 Pass 26 Pass 46 66 86 106 126 7 Pass 27 Pass 47 67 87 107 127 8 Pass 28 Pass 48 68 88 108 128 9 Pass 29 Pass 49 69 89 109 129 10 Pass 30 Pass 50 70 90 110 130 11 Pass 31 Pass 51 71 91 111 131 12 Pass 32 Pass 52 72 92 112 132 13 Pass 33 Pass 53 73 93 113 133 14 Pass 34 Pass 54 74 94 114 134 15 Pass 35 Pass 55 75 95 115 135 16 Pass 36 Pass 56 76 96 116 136 17 Pass 37 Pass 57 77 97 117 137 18 Pass 38 Pass 58 78 98 118 138 19 Pass 39 Pass 59 79 99 119 139 20 Pass 40 Pass 60 80 100 120 140 111111111/ Based onoingAew elude that the installed roofing tile at the above referenced project is capable to resist the applied test load. *v Qre;Ng [gticjitde, ti1�t if meets the Miami Dade Building Code Compliance Protocol TAS 106. Attached is the roof plan shot �ipprq imate, test 1pcatip Re'sg atfull�Su$nhit ed . 7. :* ..:_„. \.y'vTATF OF : 1-vsZ: 10.4.2017 V n yyagar,M.,Balakrishnan y; kt 4 e Statf/d rittg Cdr# $A1O7. 0.\ `• e''ei8 /0 M:‘%00 N `�`