MC-18-224
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-296225 Permit Number: MC -1-18-224 Scheduled Inspection Date: February 06, 2018 Inspector: Perez, JanPierre Owner: FELIPE, DANIEL NAVA Job Address: 1104 NE 98 Street Miami Shores, FL 33138 - Project: <NONE> Contractor: QUALITY AIR CONDITIONING Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132050180360 Phone: (954)971-1000 Building Department Comments AC CHANGE OUT 4 TON Infractio Passed Comments INSPECTOR COMMENTS False 2,/ ( Inspector Comments Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. February 05, 2018 For Inspections please call: (305)762-4949 Page 26 of 43 Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Permit Permit NO. MC -1-18-224 Permit Type: Mechanical - Residential Work Classification: A/C Replacement Permit Status: APPROVED Issue Date: 2/1/2018 Expiration: 07/31/2018 Parcel Number Applicant 1104 NE 98 Street Miami Shores, FL 33138- 1132050180360 Block: Lot: DANIEL NAVA FELIPE Owner Information Address Phone Cell DANIEL NAVA FELIPE 1104 NE 98 Spur MIAMI SHORES FL 33138- (786)707-9445 1104 NE 98 Spur MIAMI SHORES FL 33138- Contractor(s) QUALITY AIR CONDITIONING Phone (954)971-1000 Cell Phone Valuation: Total Sq Feet: $ 6,859.00 0 Tons: 4 Additional Info: AC CHANGE OUT 4 TON Classification: Residential Approved: In Review Comments: Date Denied: Scanning: 3 Date Approved:: In Review Type of Work: Fees Due CCF DBPR Fee DCA Fee Education Surcharge Penalty Fee Permit Fee Scanning Fee Technology Fee Work without Permit Fee Total: Amount $4.20 $3.60 $2.40 $1.40 $100.00 $240.07 $9.00 $5.60 $240.07 $606.34 Pay Date Pay Type Invoice # MC -1-18-66264 01/29/2018 Check #: 50789 02/01/2018 Check #: 50793 Amt Paid Amt Due $ 50.00 $ 556.34 $ 556.34 $ 0.00 Available Inspections: Inspection Type: Final Review Mechanical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDA rtify that all the construction and zoning. Futhe m r'I au Authorized Signatur Owner oregoing information is accurate and that all work will be done in compliance with all applicable laws regulating rize the above-named contractor to do the work stated. Applicant Building Department Copy / Contractor / Agent February 01, 2018 Date February 01, 2018 1 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑PLUMBING • MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 1104 NE 98TH STREET RECEIVED JAN 2 9 2018 FBC 20n Master Permit No. ci1'f Sub Permit No. ❑ EXTENSION ❑RENEWAL ❑ REVISION ❑ CHANGE OF CONTRACTOR ❑ CANCELLATION ❑ SHOP DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:11-3205-018-0360 Is the Building Historically Designated: Yes Occupancy Type: SF Load: Construction Type: Flood Zone: OWNER: Name (Fee Simple Titleholder): DADA FAMILY LLC Address:11900 BISCAYNE BLVD #264 BFE: NO X FFE: Phone#: 786-707-9445 City: NORTH MIAMI State: FL Zip: 33181 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: QUALITY AIR CONDITIONING Address: 720 W McNAB RD Phone#: 954-971-1000 city: FORT LAUDERDALE Qualifier Name: Michael L Buller State: FL State Certification or Registration #: CAC010333 DESIGNER: Architect/Engineer: Address: Zip: 33309 Phone#: 954-971-1000 Certificate of Competency #: Phone#: State: Zip: City: Value of Work for this Permit: $ 6859 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ■❑ Repair/Replace Description of Work: A\C CHANGEOUT 4.0 TON SPLIT SYSTEM D Demolition Specify color of color thru tile: Submittal Fee $ Permit Fee $ itt®l,) fi CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ 2(10 • 0-. Structural Reviews $ I.N. c1/44) (Revised02/24/2014) Bond $ .2e:P TOTAL FEE NOW DUE $ 1w Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature WNER or AGENT The foregoing instrument was acknowledged before me this 26day of JANUARY Daniel Nava ,2018 ,by , who is personally known to me or who has produced DL as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: 1,4 OAR oe ************** r�¥, APPROVED BY (Revised02/24/2014) Candace 411'J. Gomola NOTARY PUBLIC = STATE OF FLORIDA i Commit GG011601 gig* §aNIVA* i5************************************************************** /7 2L1+ 4� SignaKare 196-/-'11(- CONTRACTOR The foregoing instrument was acknowledged before me this 26day of JANUARY Michael L Buller 20 1 8 , by , who is personally known to me or who has produced DL as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: NOTARY PUBLIC STATE OF FLORIDA Comm# GG011601 Expires 8/25/2020 Plans Examiner Zoning Structural Review Clerk STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 2601 BLAIR STONE ROAD (850) 487-1395 TALLAHASSEE FL 32399-0783 BULLER, MICHAEL L QUALITY AIR CONDITIONING COMPANY, INC. 1664 PEBBLE BEACH BLVD GREEN COVE SPRINGS FL 32043 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridaticense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and team more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CAC010333 ISSUED: 02/09/2017 CERTIFIED AIR COND CONTR BULLER, MICHAEL L QUALITY AIR CONDITIONING COMPANY, IS CERTIFIED under the provisions of Ch.489 FS. Expiralon ogle AUG 31. 2018 L1202090000362 DETACH HERE MATILDE MILLER, INTERIM SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD The CLASS AAIR CONDITIONING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 BULLER, MICHAEL L QUALITYAIR CONDITIONING,COMPANY, INC. 720 WEST MCNOB FORT LAUDERDALE FL 33309 ISSUED: 02/09/2017 DISPLAY AS REQUIRED BY LAW SEQ # L1702090000862 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2017 THROUGH SEPTEMBER 30, 2018 DBA: QUALITY AIR CONDITIONING COMPANY Receipt #:HEAT NG/AIRCONDITION CONT Business Name: INC Business Type: (CLASS B AIR CONDITIONING CONTR) Owner Name: MICHAEL L BULLER-QUALIFIER Business Opened:o8/04/2009 Business Location: 720 W MCNAB RD State/County/Cert/Reg:cAcolo333 FT LAUDERDALE Exemption Code: Business Phone: 954-971-1000 Rooms Seats Employees 18 Machines Professionals For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 54.00 0.00 0.00 0.00 0.00 0.00 54.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT WHEN VALIDATED Mailing Address: This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. QUALITY AIR CONDITIONING COMPANY I: 720 W MCNAB RD FORT LAUDERDALE, FL 33309 2017 - 2018 Receipt #1CP-16-00012270 Paid 07/13/2017 54.00 07/12/2017 Effective Date 2017 FLORIDA LIMITED LIABILITY COMPANY ANNUAL REPORT FILED DOCUMENT# L14000123850 Apr 26, 2017 Entity Name: DADA FAMILY LLC Secretary of State CC3524723250 Current Principal Place of Business: 11900 BISCAYNE BLVD STE 264 NORTH MIAMI, FL 33181 Current Mailing Address: 11900 BISCAYNE BLVD STE 264 NORTH MIAMI, FL 33181 US FEI Number: 47-1554362 Name and Address of Current Registered Agent: ELAN BUSINESS SERVICES, CORP 1116 CEDAR FALLS DR WESTON, FL 33327 US Certificate of Status Desired: No The above named entity submits this statement for the purpose of changing its registered office or registered agent, or both, in the State of Florida. SIGNATURE: Electronic Signature of Registered Agent Authorized Person(s) Detail : Title MGR Title MGR Name NAVA, DANIEL Name VIEIRA, DELIA Address 11900 BISCAYNE BLVD Address 11900 BISCAYNE BLVD STE 264 STE 264 City -State -Zip: NORTH MIAMI FL 33181 City -State -Zip: NORTH MIAMI FL 33181 Date I hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath; that l am a managing member or manager of the limited liability company or the receiver or trustee empowered to execute this report as required by Chapter 605, Florida Statutes; and that my name appears above, or on an attachment with all other like empowered. SIGNATURE: DANIEL NAVA MANAGER 04/26/2017 Electronic Signature of Signing Authorized Person(s) Detail Date Property,Scarch Application - Miami -Dade County 4 WV - Page 1 of 1 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3205-018-0360 Property Address: 1104 NE 98 ST Miami Shores, FL 33138-2508 Owner DADA FAMILY LLC Mailing Address 11900 BISCAYNE BLVD #264 NORTH MIAMI, FL 33181 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds l Baths / Half 3 / 2 / 0 Floors 1 Living Units 1 Actual Area 2,438 Sq.Ft Living Area 1,799 Sq.Ft Adjusted Area 2,079 Sq.Ft Lot Size 9,040 Sq.Ft Year Built 1948 Assessment Information Year 2017 2016 2015 Land Value $325,477 $303,134 $275,576 Building Value $146,856 $146,856 $148,080 XF Value $0 $0 $0 Market Value $472,333 $449,990 $423,656 Assessed Value $472,333 $201,685 $200,284 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $0 $248,305 $223,372 Homestead Exemption $151,685 $25,000 $25,000 Second Homestead Exemption $0 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 5-6 53 42 PB 43-69 REV PL MIAMI SHORES SEC 8 LOT 19 BLK 180 LOT SIZE IRREGULAR Generated On : 1/29/2018 Taxable Value Information Previous Sale 2017 2016 2015 County $100 Exemption Value $0 $50,000 $50,000 Taxable Value $472,333 $151,685 $150,284 School Board Sales which are qualified Exemption Value $0 $25,000 $25,000 Taxable Value $472,333 $176,685 $175,284 City Exemption Value $0 $50,000 $50,000 Taxable Value $472,333 $151,685 $150,284 Regional Exemption Value $0 $472,333 $50,000 $151,685 $50,000 $150,284 Taxable Value Sales Information Previous Sale Price OR Book - Page Qualification Description 11/30/2017 $100 30784-1436 Corrective, tax or QCD; min consideration 02/18/2016 $690,000 29969-2830 Qual by exam of deed 04/01/1972 $50,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: http://www.miamidade.gov/propertysearch/ 1/29/2018 \x� This form u "ac�.511 any ALL air conditioning replacement permit applications. Each unit change -out must be on its ovfd'ata sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): 1 104 NE 98TH ST RECEIVED JAN 2 9 2018 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 IR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: men' —� City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SL•A$ ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVAT'IM •: • A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED • • .. • • • • •.•. •• • •••• • Change disconnectingmeans: YES ❑ NO ❑■ ARHI Sheet Attached: YES Q NO• • • • 0 Contract Attach>sd: YES ❑� • .. •__• • . • UNIT BEING REPLACED DATA • DIEMLJNIT . CARRIER MANUFACTURER ; CARRIER • • FE4ANB006 AHU or PKG. UNIT MODEL# FF4Ak1Bj48C008 24ANB748C310 COND. UNIT MODEL # 24A9NB748C0n • •. • • 10 KW HEAT 10 •• • 4.0 NOM TONS 4.0 AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EER/SEER YES NON REPLACING DUCTS YES NON YES NOY REPLACING THERMOSTAT YES NOY YES NOY NEW 4"CONCRETE SLAB YES NOY YES NON NEW ROOF STAND YES NON YES NOY NEW RETURN PLENUM BOX YES NOY 1. Minimum Circuit Ampacity (Wire Size): 8AWG 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 40 3. Voltage of Circuit (208/240/480): 240 4. Size Disconnecting Means: Contractor's Company Name: QUALITY AIR CONDITIONING Phone: 954-971-1000 CAC01 0333 State Certifica •r Re ' tratio Si gnatuP( (Revised02/24/2014) (Qualifier's signature) Certificate of Competency No. Date: 1/26/18 • •• • • • • • • • • . 'AirCond tioning Company' 04==- CORPORATE OFFICES 720 W. McNab Road • Fort Lauderdale, FL 33309 Phone 954-971-1000 • Fax 954-978-6658 VISIT US AT www.QUALITYAC.com "The Most Respected Name in the Business" DATE / / /`f / /SCUSTOMER ## f / CUSTOMER NAME C)/ T� I/q��'��r,, Iii L ADDRESS //"7 A*, . E. ,,P'�J .>J�' CITY/ST/ZIP i77/07%%21 _:v , -tS M-3"3. f H PHONE (6)2)CELL(.0I) 17I 19677 EMAIL ADDRESS OPTIONS _.?;CARRIER U CARRIER SPLIT WATER COOLED ❑ AMERICAN STANDARD IJ BOSCH ❑ 1 ❑ RHEEM ❑ HYDROTECH ❑ cu/rte ogy '��S 75/6Z , AHUAAIB#P ,4 [J/ ik.) jr r • • • • HEATER SIZE A0g • • • • • • 1 • i BTUH SIZE 7/"G� r � • a- 3 `-- , SEER .4i PERMIT FEES $175.00 1 a $175.00 $175.00 • •••• ; MFG. WARRANTY LABOR 1 YR PARTS /OM COMP %GSR LABOR 1. YR PARTS YR COMP YR LABOR 1 413 PARTS •YR• OMP YR' •• • •. PROPOSAL IS VALID FOR 30 DAYS FROM THE ABOVE DATE. GENERAL CONDITIONS AND WARRANTY INFORMisl]ION ON REVERSE SIDE. • NEW EQUIPMENT WILL REPLACE EXISTING EQUIPMENT IN SAME LOCATION. EXISTING AIR DISTRIBUTION SYSTEM TO BE REUSED (DUCTWORK, VENTS & PLENUM). EXISTING REFRIGERANT PIPING TO BE REUSED. EXISTING CONDENSATE DRAIN LINE WILL BE REUSED. EXISTING POWER AND CONTROL WIRING WILL BE REUSED. TOTAL $ 50% DEPOSIT $ BALANCE DUE UPON COMPLETION OF INSTALLATION $ PAID WITH CHECK # CC APPROVAL # t O"�-o. / QUALITY AIR CONDITIONING COMPANY, INC. CUSTOMER / PROPERTY OWNER BY SIGNING, ALL TERMS AND GENERAL CONDITIONS ARE ACCEPTED. DATE .a `l et/� SPECIAL INSTRUCTIONS "QUALITY AIR CONDITIONING COMPANY'S GOAL IS TO PROVIDE QUALITY SERVICE AT A REASONABLE .PRICE." - REG C., OWNER FORM 90-10 (rev. 4-17) White - Company Yellow - Customer • • • • • • 1• • •••• OO r • • • • • • • • • • 1 • i • • DISCOUNT a- 3 `-- 1 PERMIT FEES $175.00 a $175.00 $175.00 ; TOTAL 4‘4 ' 1 1 • NEW EQUIPMENT WILL REPLACE EXISTING EQUIPMENT IN SAME LOCATION. EXISTING AIR DISTRIBUTION SYSTEM TO BE REUSED (DUCTWORK, VENTS & PLENUM). EXISTING REFRIGERANT PIPING TO BE REUSED. EXISTING CONDENSATE DRAIN LINE WILL BE REUSED. EXISTING POWER AND CONTROL WIRING WILL BE REUSED. TOTAL $ 50% DEPOSIT $ BALANCE DUE UPON COMPLETION OF INSTALLATION $ PAID WITH CHECK # CC APPROVAL # t O"�-o. / QUALITY AIR CONDITIONING COMPANY, INC. CUSTOMER / PROPERTY OWNER BY SIGNING, ALL TERMS AND GENERAL CONDITIONS ARE ACCEPTED. DATE .a `l et/� SPECIAL INSTRUCTIONS "QUALITY AIR CONDITIONING COMPANY'S GOAL IS TO PROVIDE QUALITY SERVICE AT A REASONABLE .PRICE." - REG C., OWNER FORM 90-10 (rev. 4-17) White - Company Yellow - Customer • • • • • • 1• • ENGINEERING Technical Evaluation Report EXPRESS E.X.P.E.R.T (Engineering Express Product Evaluation Report) 160 SW 12TH AVE SUITE 106, DEERFIELD BEACH, FL 33442 (954) 354-0660 I ENGINEERINGEXPRESS.COM EVALUATION SUBJECT: CARRIER SPLIT UNITS . REPORT HOLDER: CARRIER ENTERPRISE OF FLORIDA 2000 PARKS OAKS AVE ORLANDO, FL 33428 USA (954) 247-2003 1 FL.CARRIERENTERPRISE.COM SCOPE OF EVALUATION (compliance with the following codes): DIVISION: 23 08 00—COMMISSIONING OF HVAC THIS DOCUMENT CONTAINS (5) PAGES: THE FIRST PAGE MUST BEAR AN ORIGINAL SIGNATURE & SEAL OF THE CERTIFYING PE TO BE VALID FOR USE (Issued September 12th, 2016 Subject to Renew September 11th, 2017) THIS IS A STRUCTURAL (WIND) PERFORMANCE EVALUATION ONLY. NO ELECTRICAL OR TEMPERATURE PERFORMANCE RATINGS OR CERTIFICATIONS ARE OFFERED OR IMPLIED HEREIN. This Product Evaluation Report is being issued in accordance with the requirements of the Florida Building Code Fifth Edition (2014) per FBC Section 104.11, FMC 301.15, FBC Building Ch. 16, ASCE-7-10, FBC Existing Building sections 701.1, 706.6.1, FBC Building 1522.2, and FBC Residential M1202.1, M1301.1, FS 471.025, including Broward County Administrative Provisions 107.3.4. The product noted on this report has been tested and/or evaluated as summarized herein. IN ACCORDANCE WITH THESE CODES EACH OF THESE REPORTS MUST BEAR THE ORIGINAL SIGNATURE & RAISED SEAL OF THE EVALUATING ENGINEER. SUBSTANTIATING DATA: • Product Evaluation Documents Substantiating documentation has been submitted to support this TER and is summarized in the sections that follow. • Structural Engineering Calculations Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: • Maximum allowable unit panel wind pressure connection integrity • Maximum allowable uplift, sliding, & overturning moment for ground and roof applications Calculation summary for this TER is provided in the forces summary table. No 33% increase in allowable stress has been used in the design of this product. Microsoft Excel was used to carry out the calculations present in this report. INSTALLATION: The product(s) listed in this report shall be installed in strict compliance with this TER & manufacturer -provided model specifications. The product components shall be of the material specified in the manufacturer -provided product specifications. All screws must be installed in accordance with the applicable provisions & anchor manufacturer's published installation instructions. LIMITATIONS & CONDITIONS OF USE: Use of this product shall be in strict accordance with this TER as noted herein. See final page for complete limitations and conditions of use. OPTIONS: This evaluation is valid for all CARRIER models present in the table located on the final page. FINISH: Baked enamel. NOTE: GRAPHICAL DEPICTIONS IN THIS REPORT An FOR ILLUSTRATIVE PURPOSES ONLY. ACTUAL UNITS MAK DIFFoER SLIGHTIAliglAPEARVIa:•• • • • •• •• • UNIT CASING MATERIAL: '• • • 0.86mm galvanized sheet steel ASTM M53 EDDS cold rolled CU,I•fgi; removable top panel. 1.14mm galvanized sheet sttgl•ASI:M A653 EDD coid rolled steel for base pan. Side pfdtector stel gAlle ASTiM•A510 02.03mm vertical wire and 02.68rIrrtjdtiiptal wi:e, secured with t't € sheet metal screws into top and base parr. •••• • INSTALLATION: • • • '• Shall follow manufacturer specifications ai well as their:t•rmation Wititsd herein. • • • • • •• • •• • STRUCTURAL PERFORMANCE: • • • Models referenced herein are subject to the following design limitations: ASCE7-10 Exposure Category C, Risk II Up to and including 175mph (Vult) for up to 200' MRH**, HVHZ*** Up to and including 170mph (Vult) for up to 250' MRH**. HVHZ*** Up to and including 200mph (Vult) for up to 200' MRH**, Non-HVHZ*** Ground or Roof Application per installation instructions **Mean Roof Height ***High Velocity Hurricane Zone Maximum Rated Wind Pressure: 193psf Lateral, 93psf Uplift (less Dead Load) Site specific wind analysis may produce alternate limitations provided maximum rated wind pressure is not exceeded. • • ORIGINAL SIGNATURE AND RAISED SEAL REQUIRED TO BE VALID PER CODE: Frank L. Bennardo, P.E., SECB ENGINEERING EXPRESS® PE #0046549 CA #9885 The FBC 14 defines APPROVED SOURCE (Section 22) as: "An independent person, firm or corporation. approved by the building official, who is competent and experienced in the application of engineering principles to materials, methods or systems analyses " Engineering Express® professionals meet the competency requirements as defined in the FBC and can seal their work. Engineering Express® is regularly engaged in conducting and providing engineering evaluations of single -element and full-scale building systems. CARRIER SPLIT UNITS Engineering Express° 1 TER -16-3190.1 SECTION 2 PRODUCT INSTALLATION Condenser Unit ® I I IIi1IICIi11 III 11 11 II;I:I!I III 1 i1I 11 11! I ILII'11.II' II 1. ® iF II�I' Note: Unit shown for Illustration purposes only. TIE -DOWN STRAP & CLIP SCHEDULE Roof or ground structure / substrate (concrete, steel, aluminum see schedule below) e -down clips 1 or 2. See tables below for specifications + CabinetHelght* Ground or Roof Tie -down Strap Strap Tie -down Clips (1) Tie -down Clips (2) Table 1 Ground NA NA 8 4 Up to 60' (801 2 Required 8 4 Up to 120' (150') 2 Required 8 4 Up to 200' (2501 2 Required 8 4 Table 2 Ground NA NA 8 4 Up to 60' (801 2 Required 8 4 Upto120'(150') 2 Required 8 4 Up to 200' (250') 2 Required 8 4 *The value shown in parentheses indicates the allowable roof height in 170mph conditions. i.e. 60' (801 indicates an allowable roof height of 60' for 175mph or 80' for 170mph Vult + See tables on last page for cabinet classification. Note: Straps shall be wrapped as shown in details on section 4. The straps shall be tightened to a snug fit around the unit Straps shall be 1" width and 22ga galvanized metal. For Non-HVHZ, use (2) metal straps, up to 200' MRH. Values shown in table are minimum specified. Using stronger straps per each height is allowed at installer's discretion. ANCHOR TO HOST STRUCTURE SCHEDULE Unit + Model Ground or Roof Height* Anchor Type Concrete 3,000 Psi 1/8 Min A36 Steel 1/W' Min 6061-T6 Aluminum Table 1 Ground A NA NA Up to 60' (801 NA B B Up to 120' (150') NA B. 8 Up to 200' (250') NA 8 8 Table 2 Ground A NA NA _Up to_60' (80') NA B B Up to 120' (150') NA B B Up to 200' (250') NA B B 01° Note: installers must ensure that screws used to fasten the tie -down clips with the unit base pan do not touch the coil in order to prevent any damage to the colL TIE -DOWN CLIP (1) (GROUND AND ROOF APPLICATION) Miami Tech CUTD 1" wide ASTM A653 galvanized steel 0.07" thick of varying length (FL19731.2) or equivalent for all cabinets tied down to a roof structure or ground structure; fasten clip to structure using anchor from Anchor Schedule to Host Structure Table and (2) #10 SS 410 self -drilling screw to fasten dip to unit base pan. Install In unit with quantities shown in Tie -down Strap & Clip Schedule. Locate clips at 3" min away from the appropriate corner using four dips per side (two at each corner) and four clips opposite side in the same configuration. Miami Tech kit # CBCUTD4KG for ground & kit # CBCUTD4KR for roof application. o .�• oU •• ir•• • • • ••• •• TIE -DOWN CUP (2) (GROUND AND ROOF Ap eica n N) • • • BMP Clips 2' wide ASTM A283 (Grade D) stete►0.1.1ithick of NI,N1 • • length for all cabinets tied down jo,roof stri4'ture or ground stticture • or equivalent clips; fasten clipte structure using424agchorfrom 4rlERdt • Schedule to Host Structure Table and (4) #12 814E•Grade 5 sheet metal screw to fasten clip to unit base pan. Instalfn t?nit with quantities shown in Tie -down Strap & Clip Schedule. Locate dips at 3" from the appropriate corner. BMP part number TD -042. •••• • • •••• •• • •• • • • • • •• • •• • • • •••• • �• • • • • • Tie -down Strap & Clio: (for roof applications) - Minimum edge distance 3" from the unit corners. - Use a minimum of tie -down straps per side equally spaced. - Clip height shall be adequate to fit SMS within base pan height. Verify height on site. - Place an adjacent (1) #10 SMS to avoid the straps slip off. Anchor Tvpes to Host Structure: A. — 1/4" ELCO ULTRACON SS4 Anchor embedded 1 3/4"" in 3,000 psi concrete. 2 1/2" from edge minimum. NOA No. 13-1205.05 B. — 1/4" -20 UNC SAE Grade 5 bolt min. 1/2" from edges with nut and washer OD 1" NA. - No anchors apply. IN ALL CONDITIONS IT IS THE RESPONSIBIL TY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF WITHSTANDING THE RATED GRAVITY, LATERAL, AND UPLIFT FORCES BY SITE-SPECIFIC DESIGN. NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, IS OFFERED BY ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY DESIGN FORCE LOADS INCURRED BY THIS UNIT. ENGINEERING EXPRESS® 160 SW 12TH AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 2 of 5 (954) 354-0660 ENGINEERINGEXPRESS.COM CARRIER SPLIT UNITS Engineering Express® 1 TER -16-3190.1 SECTION 3 SUPPORTING CALCULATIONS & SUMMARY FORCES SUMMARY Unit Model` Ground or Roof Height* Lateral Pressure (Psf) Uplift Pressure (Psf) Large Side Force (lbs) Large Side Overturn (lbs -in) Large Side Tension (lbs) Short Side Force (lbs) Short Side Overturn (lbs -in) Short Side Tension (lbs) Uplift Force (lbs) Table 1 Ground 43.2 0 482.0 11082.0 315.0 482.0 11082.0 315.0 0.0 Up to 60' (80') 151.2 73.1 1688.0 49656.0 1519.0 1688.0 49656.0 1519.0 622.0 Up to 120' (150') 173.8 84.1 1940.0 57082.3 1753.0 1940.0 57082.3 1753.0 715.0 Up to 2001(250') 193.0 93.4 2155.0 63393.3 1951.0 2155.0 63393.3 1951.0 794.0 Table 2 Ground 43.2 0 482.0 11082.0 315.0 482.0 11082.0 315.0 0.0 Up to 60' (80') 151.2 73.1 1688.0 49656.0 1519.0 1688.0 49656.0 1519.0 622.0 ,Up to 120' (1501 173.8 84.1 1940.0 57082.3 1753.0 1940.0 57082.3 1753.0 715.0 Up to 2001(250') 193.0 93.4 2155.0 63393.3 1951.0 2155.0 63393.3 1951.0 794.0 Calculations performed according to the information provided by the client. Cabinets were assumed solid (0% porosity) fo shear and tension calculation purposes. PANEL INTEGRITY SUMMARY •••• • . • • •••• •. • • • Unit + Model Ground or Roof Height* Panel Name Applied PP Wind Pressure (Ib/ftt) Force on Panel (lbs) AddI Screw Needed (Pcs) -_..._ Ad�it(4t1a) reinforreroent re uiret!• and q d1 }rtal• man faciaring Table 1 Ground TOP PANEL 0.0 0.0 - • • • • • • No • .• •• •• • CONTROL COVER 43.2 50.4 - SERVICE PANEL 43.2 91.4 - Up to 60' (80') TOP PANEL 73.1 621.9 - No CONTROL COVER 151.2 176.5 - SERVICE PANEL 151.2 319.9 - Up to 120' (150') TOP PANEL 84.1 715.4 - No CONTROL COVER 173.8 202.9 - SERVICE PANEL 173.8 367.7 Up to 200' (250') TOP PANEL 93.4 794.5 - No CONTROL COVER 193.0 225.3 - SERVICE PANEL 193.0 408.4 - Table 2 Ground TOP PANEL 0.0 8.0 - No CONTROL COVER 43.2 50.4 - SERVICE PANEL 43.2 91.4 - Up to 60' (80') TOP PANEL 73.1 621.9 - No CONTROLCOVER 151.2 176.5 - SERVICE PANEL 151.2 319.9 - Up to 120' (150') TOP PANEL 84.1 715.4 - No CONTROL COVER 173.8 202.9 - SERVICE PANEL 173.8 367.7 - Up to 200' (250') TOP PANEL 93.4 794.5 - No CONTROL COVER 193.0 225.3 - SERVICE PANEL 193.0 408.4 - *The value shown in parentheses indicates the allowable roof height in 17omph conditions. i.e. 60' (801 indicates an allowable roof height of 60' for 175mph or 80' for 170mph Vult. `See tables on sheet 5 for cabinet classification. ENGINEERING EXPRESS® 160 SW 12Th AVE. SUITE 106 DEERFIELD BEACH, FL 33442 (954) 354-0660 ENGINEERINGEXPRESS.COM • • •• • • • • • •• • •• • • • •••• • • • • •• • • • • •• • • •• • • • • • • • • Page 3 of 5 CARRIER SPLIT UNITS Engineering Express® 1 TER -16-3190.1 SECTION 4 DETAILS (2) 1"x22ga GALV. ASTM A36 STEEL STRAP. STRAPS SHALL BE SECURELY TIGHTENED SNUG AGAINST UNIT, TYP. STAND RAIL (BY OTHERS), TYP. MECHANICAL UNIT N.T.S. FRONT ISOMETRIC STAND RAIL (BY OTHERS), TYP. (2) #14 SMS AT EACH STRAP END TO WEB OF THE SUPPORT ANGLE SUPPORT ANGLE SEE NOTE BELOW MECHANICAL UNIT N.T.S. FRONT ISOMETRIC TIE -DOWN CLIP A. SEE CLIP. NOTE: LSUPPORT ANGLE, SEE NOTE ANCHOR PER J SCHEDULE STAND RAIL (I -BEAM) BY OTHERS CONTROL BOX SUPPORT ANGLE SEE NOTE BELOW MECHANICAL UNIT N.T.S. DATUM FACE CLINE", BACK ISOMETRIC ••• • • • • • • •• • 6iANDJ7 %m ht. (a O• THERS), • •••• DIM.2 •4•••• •• •• •• • I • • • • DIM. 3 • • • • • •• • DIM.4 I (1) 1"x22ga GALV. ASTM A36 STEEL STRAP, SHALL PASS OVER THE UNIT TO I -BEAM ON OPPOSITE SIDE. (2) #14 SMS AT EACH STRAP END TO UNDERSIDE OF THE I -BEAM TIE -DOWN CLIPS & STRAPS N.T.S. ELEVATION CLIP© SUPPORT ANGLE SEE NOTE BELOW • • • • •• • • • • • •• • •• • • • • ••• • • • • •• • • • • •• • TIE -DOWN CLIP LAYOUT N.T.S. PLAN TIE -DOWN CLIP OFFSETS: DIM. 1 5.00" MAX OFFSET FROM DATUM FACE DIM. 2 5.00" MAX OFFSET FROM OPPOSITE FACE DIM. 3 5.00" MAX OFFSET FROM DATUM FACE DIM. 4 10.00" MAX OFFSET FROM OPPOSITE FACE Note: Miami Tech support angle part number CBCAB30K, CBCAB42K, under NOA #16-0601.01 or equivalent is permitted. ENGINEERING EXPRESS® 160 SW 12T" AVE. SUITE 106 DEERFIELD BEACH, FL 33442 (954) 354-0660 ENGINEERINGEXPRESS.COM •• • • • • • • • •• • • • • Page 4 of 5 .CARRIER SPLIT UNITS Engineering Express® 1 TER -16-3190. CABINETS & DIMENSIONS TABLE 1 UNIT MODEL WIDTH (in) DEPTH (In) HEIGHT (In) WEIGHT (lbs) CH14"018 23.13 23.13 35.25 136 CH14"024 25.75 25.75 35.25 144 CH14**030 31.19 31.19 31.81 158 CH14**036 31.19 31.19 28.44 170 CH14"042 31.19 31.19 39.13 201 CH14**048 31.19 31.19 28.44 197 CH14"060 31.19 31,19 31.81 212 CA16'18 31.19 31.19 28.44 142 CA16"24 31.19 31.19 28.44 142 CA16"30 31.19 31.19 31.81 150 CA16"36 35.00 35.00 28.44 165 CA16**42 35.00 35.00 39.13 213 CA16**48 35.00 35.00 39.13 264 CA16"60 35.00 35.00 45.94 272 CA14"18 23.13 23.13 24.81 123 CA14**24 25.75 25.75 25.00 119 CA14**30 31.19 31.19 31.81 151 CA14**36 31.19 31.19 24.81 134 CA14"'42 31.19 31.19 39.13 192 CA14**48 31.19 31.19 28.44 182 CA14"60 31.19 31.19 31.81 197 H 1 ILA . I I 144444 I ..�" Note: Image Is not to scale and is for illustration purposes only. Actual units may differ slightly In appearance. TABLE 2 UNIT MODEL WIDTH (1n) DEPTH (in) HEIGHT (in) WEIGHT (lbs) 25HB*518 31.19 31.19 28.94 169 25HB*524 35.00 35.00 32.31 200 25HB*530 35.00 35.00 32.31 196 25HB*536 35.00 35.00 35.75 215 25HB*542 35.00 35.00 28.94 245 25HB*548 35.00 35.00 28.94 260 25HB*560 35.00 35.00 39.13 294 25HC*418 23.13 23.13 35.25 136 25HC'424 25.75 25.75 38.50 144 25HC*430 31.19 31.19 31.81 158 25HC*436 31.19 31.19 28.44 170 25HC*442 31.19 31.19 39.13 201 25HC*448 31.19 31.19 28.44 127, . , 25HC*460 31.19 31.19 • 31.81 • 217• • • 4 24AB'618 23.13 23.13 •28.69: •125 • 24AB'624 31.19 31.19 • •2131• :143 • • • 24AB"630 31.19 31.19' • •32.3t 153• 24AB*636 35.00 35.00 . 'MI/ :i • • 24AB*642 35.00 35.00 •r• • 39.13 0.0900 •213•' 24AB*648 35.00 35.00 • • Si y34 :2614 • • 24AB*649 35.00 35.00 •.39,x3 231 24AB*660 35.00 35.00 : 4.941 • 272 • 24AB'661 35.00 35.00 4 45494 : 2?2' • 24AC"418 23.13 23.13 • 924.8+1 423 • 24AC*424 25.75 25.75 25.00 414• 9 • 24AC'430 31.19 31.19 31.81 151 24AC'436 31.19 31.19 24.81 134 24AC'442 31.19 31.19 39.13 192 24AC*448 31.19 31.19 28.44 182 24AC*460 31.19 31.19 31.81 197 • •• • • • ••••• • •• • • 000000 • . LIMITATIONS & CONDITIONS OF USE: Use of this product shall be in strict accordance with this TER as noted herein The supporting host structure shall be designed to resist all superimposed loads as determined by others on a site specific basis as may be required by the Authority Having Jurisdiction Host structure conditions which are not accounted for in this product's respective anchor schedule shall be designed on a site-specific basis by a registered professional engineer No evaluation is offered for the host supporting structure by use of this document: Adjustment factors noted herein and the applicable codes must be considered, where applicable All supporting components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times, Fasteners must penetrate the supporting members such that the full length of the threaded portion is embedded within the main member, All anchors. screws, straps, clips, and attachment part can be substituted for equivalent parts, as long as the capacities of the equivalent parts are equal or stronger This evaluation does not offer any evaluation to meet large missile impact debris requirements which typically are not required (or this type of product, All of the wind resisting exterior panels, individually meet or exceed their capacity to resist the design wind loads as staled in the calculations as required by the Florida Building Code Fifth Edition (2014). Due to the indeterminate nature of these units, distortion and deflection cannot be accurately evaluated. but with diaphragm action of exlemal components and internal stiffeners, the base unit has the capacity to withstand these forces with individual external parts being contained., Yearly inspections, during equipment maintenance or after a named storm; ail screws, cabinet components, clips. anchor. bolls, straps and cables are to be verified by the A/C contractor. All damaged cabinet components, loose, corroded, broken screws or anchor bats shall be replaced to ensure structural integrity fa hurricane wind forces ENGINEERING EXPRESS® 160 SW 12Th AVE. SUITE 106 DEERFIELD BEACH, FL 33442 (954) 354-0660 ENGINEERINGEXPRESS.COM Page 5 of 5 �..i CERTIFIED° www.ahridirectory.org This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number : 9383761 Date : 01-29-2018 Model Status : Production Stopped Old AHRI Reference Number : AHRI Type : RCU-A-CB Series : INFINITY 17 COASTAL AC 2 -STAGE Outdoor Unit Brand Name : CARRIER Outdoor Unit Model Number (Condenser or Single Package) : 24ANB748C*031* Indoor Unit Brand Name : Indoor Unit Model Number (Evaporator and/or Air Handler) : FE4ANBOO6L+Ul Furnace Model Number : •••• Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, M$, MT, NC, jJp• vE, NH, • NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) • • • • • • Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 3a 2016. • Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet t c zgpional efficiency. • • • • • - • , • • -requirement. The manufacturer of this CARRIER product is responsible for the rating of this system combination. •••• •, • •• •• •- .• • • • • •••• Rated as follows in accorclarice with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance: aiirag t f Unitary Air --Conditioning & Air -Source Heat Pump p Equipment and subject torrating accuracyby AHRI-sponsored; independent; third party teestind:'.'. •• - _ _ 1) ' • • • • • ••• • • • ••• , �• w••• ••• o Cooling Capacity (A2).; Single or High Stage (95F), btuh 480b0 I i` SEER L17.00- — — l ] EER (A2) - Single or High Stage (95F) : 13.50 , T IEER:' I I '• --• s_, • • - — •• • ••• • •••• • f"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, c ick on 'Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life better' CERTIFICATE NO.: 131617091995293863 0 �.ai CERTIFIED° www.ahridirectory.org This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number : 9383761 Old AHRI Reference Number : Date : 01-29-2018 Model Status : Production Stopped AHRI Type : RCU-A-CB Series : INFINITY 17 COASTAL AC 2 -STAGE Outdoor Unit Brand Name : CARRIER Outdoor Unit Model Number (Condenser or Single Package) : 24ANB748C*031* Indoor Unit Brand Name : Indoor Unit Model Number (Evaporator and/or Air Handler) : FE4ANBOO6L+UI Furnace Model Number : •••• Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, 110, t16+ MT, N6,61461,4, NH, • • •, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) •• • • • 4 Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regipeArgi‘June 30, 20J 6. • Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet **regional eftidency •••I .requirement.--.- The manufacturer of this CARRIER product is responsible for the rating of this system combination. • • • • • _. ..•.••• _ .• _ •• • •• •••• • •' • • • • �--; •• •• ••••• •••• % Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance•4tatiNg 4f Unitary Ai Conditioning • & Air -Source Heat Pump Equipment at ndd subject totrating accuracy by;AHRI-sponsored; irides endent'thiFdpart testing, "' • ` •••• l _ •• Cooling Capacity (A2)_ Single or High Stage (95F),'btuh : 48000 % ` — a , ••,1 `• • • • • ` r ` i il+, c • • • SEER 17.00- -'-- -- _� __ - _ .... - •• • EER (A2) - Single or High Stage (95F) : 13.50 IEER : 1_ •1_'1'. r, t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating, DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. Thls Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the users individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life better 131617091995293863 i i • • •