Loading...
RC-15-1024 (2)Miami Shores Village ng Department Avenue, Miami Shores, Florida 33138 5) 795-2204 Fax: (305) 756-8972 LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING FBC 20 Master Permit No. RC -15-1024 Sub Permit No.5)Me D'am;n5r7c.lE.s ys' o V1 REVISION ❑EXTENSION ❑RENEWAL `f,� i S t PLUMBING E MECHANICAL EPUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION 0 SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9701 BISCAYNE BLVD City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel#:11-3206-014-3320 Is the Building Historically Designated: Yes NO X Occupancy Type: R-3 Load: Construction Type: V Flood Zone: X BFE: FFE: OWNER: Name (Fee Simple Titleholder): JOSE G. CASTRO & MARIA G. ALE Address:9701 BISCAYNE BLVD Phone#: 305-582-2836 City: MIAMI SHORES State: FL Tenant/Lessee Name: NIA Email: info@r-method.net Phone#: Zip: 33138 CONTRACTOR: Company Name: R -METHOD CONSTRUCTION, INC. Address: 2541 SW 119TH TERRACE Phone#: 305-914-5355 City: MIRAMAR State: FL Zip: 33025 Qualifier Name: LORENA TELLO Phone#: 305-798-7620 State Certification or Registration #: CGC 1519419 Certificate of Competency #: DESIGNER: Architect/Engineer: JOSE RUBEN JIMENEZ, ARCHITECT Phone#: 305-582-2836 City: HOLLYWOOD State: FL Zip; 33020 Address: 300 OAKWOOD LANE SUITE 100 Square/Linear Footage of Work: 955 SF Value of Work for this Permit: $ 0.00 Type of Work: ❑� Addition ❑ Alteration ❑ New ❑ Repair/Replace Description of Work: Truss shop drawing revisions required by inspections. E Demolition Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ 1 75 Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ 1 ZO Bond $ TOTAL FEE NOW DUE $ 2 I (Revised02/24/2014) rtl ( c -t -ion - Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the a ence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this 5q day of , 20 / (! , by Cho -AA , who i rsonally knoww)o me or who has produced as identification and who did take an oath. NOTARY PUBLIC: 11111111111 AIM\ Sign: Prin Seal: i RAHEMA 0. GOLDING ;.: MY COMMISSION # FF 203174 EXPIRES: June 21, 2019 Bonded Thru Notary public Underwriters Signature C CON •ACTOR\ The foregoing instrument was acknowledged before me this e 't day of C� , 20 /62 , by D , who s personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: 1111W Sign:/��� Print: �- Seal: ,«": ` RAHEMA 0. GOLDING +r "' *i MY COMMISSION # FF 203174 •-EXPIRES: June 21, 2019 ... ,1 P' Bonded Thru Notary Public Underwriters ************************************************************************************************************ APPROVED BY (Revised02/24/2014) Plans Examiner Structural Review Zoning Clerk Valley Trusses SVgp Draws ,�TYss ConlinuoUs Bracing @ in areas without plyw. sheathing Valley Truss Supporting Truss Patrol Roof Layout 12 Pitch 4to7 6" wedge nailed to buss vid 2-8d toe-natIs, of bevel cut bottom chord of valley truss Shap @ 32o_c. (see note) Supporting trusses @ ....' • • •• • • •. • • • • .•.. • • .•. • • .... • • • • • . ▪ . . •... •. .• ••. • .• .. • ..... • • Design loads_ 30 + 15 + 0:1- 1 a P$F, 1.60 QOL • • • Wind Speed 175 MPH, 1.0 PSF Dead loia' • •' _ Components and Ciadcrin8W des • ASCE 740 Enclosed Baling, g, importance factor 12 .. • Lumber. 2x4 No. 2 ND SYP min. chords 2x4 No. 3 SYP mn webs Notes: (a) Provide cont. bracing on over 6' - 3`.Connectbracing to verbrals w/2, na s_ rmust be fled to a fixed point at ends. (b) Max. spacing for vertical studs is 6„.-, 0". (c) Corm. for upllftwrlh 15c.127:loricj, l4ga.'stiap at 2'-0" o c_ • - with 4, 16d nes-eac s deaf = ASCE 7-10, FBC'201O,,.—_ �• . (d) Brace top chords of supporting trusses with plywood sheathinapt, 2x4 cont bracag at 24" o_c. C' ,•Y RTIN�,' No.• 22249 • • 'XX a•1 '7'ar Ta AO • EOF S10NAL '',11„„„,110% • • AUG 2 4 2O1 SUBMITTAL WITH $_PECIALTY ENGINEER SUBSTANCIALLYCONFORMS TODESIGN CONCEPT. , • ACCEPTED O SUB STANCIALLY CONFORMS TO DESIGN CONCEPT........-. DAS SS AIS 1 DOES NOT CONFORM TO DESIGN CONCEPT.. .. , . REVISED AS NOTED AND RESUBMIT 0 UNRESPONSIVE SUBMITTAL AS NOTED... , 0 SIGNED AND SEALED SUBMITTAL REQUIRED.. , , • • • • • • • REJECTED .. .... RESUBMIT Review is !iniad to verifying the following: 1. The specified Structural Submittals have been fismishod. 2. Submittal is signed and sealed by :he Specially Engineer, 3. The Specialty Engineer has mdcrsrood the design intent and has fined doe specified atn¢tunl criteria (No detail elect. of the celculuioru wu mads 4. The configuration set forth in the seb:ninal is c. -es te^,ens with dy Struerygt Comm Do anent (No detailed check of einensions or quantities was meds).. Notations do not constitute a Change and do not relieve the General Contactor/ .. Construction Manager from eompliunce u ; ih ry,c Ccnneet Documents, go and regu .tions. The General Contractoc'c . neeon \tarsnger is solei codes for confirming all quantities, dimensions, fabicatien solely responsible rk with Who trades and assuming that all work is performed in a techniques, and tuishctoey manor. Structures International, Inc. Consulting Structural Engineers Ate:3)304 By: ri •• • • • • • • • • • • • •• •• • • •••• • • •••• • • • • • • • •••• • • • • •••• • • •••• •• •• • • • • • • •••• • • • •• • • •• • • • • • •••• • • •+I.� t I i;zrts.c r • •� • • • • • • • • • • • • • • •• NVRT — Flat and Twisted Rafter Ties 1" x 14 G Length (in) Product Code Gauge 12 NVRT-12 14 16 NVRT-16 14 18 NVRT-18 14 20 NVRT-20 14 22 NVRT-22 14 24 NVRT-24 14 30 NVRT-30 14 36 NVRT-36 14 48 NVRT-48 14 NVRT Wood to Wood 16d or 10d 1 1/2' Nails Maximum Uplift Load (lbs) TOTAL In each member* Flat Ties Twisted Ties 6 3 5885 5885 8 4 725 724 10 5 861 860 12 6 998 996 14 7 1135 1132 NVRT Wood to Concrete • • No. of 16d or 10d 11/2 nails to Wood Framing No. of 1/4" diameter • • Tapcons to Concrete, • • ' MaxinaumU lift : • • Load {il,s" 3 3 •••►•• •-Y 588' - • 4 4 •••,•• •7•'•' .• 5 4 •••••_ . •- 6 5 •• •• wr• 7 5 •••••••• • 112_ Notes: 1) Specify "F" for Flat and "T" for Twisted when ordering. 2) Fastener values are based on a minimum of 11/2" thick wood members. 3) *Indicates no. of nails in each connected wood member. 4) ITW tapcons shall be embedded a minimum of 11/4" into concrete tiebeam or tiebeam formed with concrete filled masonry. ITW tapcons shall have a min. edge distance of 21/2" and minimum staggered spacing of 3/4" as shown. 5) Use on in Non-HVHZ. 6) For Uplift loads CD=1.6 7) See general notes, page 01. 8) This table is based on Florida Approval 16294, Table 4. 4" .1" 4 0 O 0 0 NVRT Anchor Holes dia. I" 1" UPLIFT 11141. o e e s e e s e e e e s \ 1 ro iEgc?0�� `eeeeeeeeeeee`I.to trussLENGTH FLAT HALFHALF - Connected Connected 1.14 to wall 1 2 " Min. edge distance 4900 o e e e e e e e e ee ee ee ee ee • • • •• • Do not Use circled holes • •• • • • • • • • • •••,. • • • • • •• • 16d "Tapcons LENGTH TWISTED 8 Tie Beam formed with concrete filled masonary or concrete tie beam