Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-17-1262
BUILDING PERMIT APPLICATION ❑ BUILDING ❑ ELECTRIC ❑PLUMBING ❑ MECHANICAL Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 1.CEIVED AY -97017 F C201U Master Permit No.'"C-- 1,—Z10 2 Sub Permit No.g --1?,C2 ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9325 N BAYSHORE DRIVE City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): OMAR CASSOLA Phone#: 33138 NO FFE: Address: 9325 N BAYSHORE DRIVE MIAMI SHORES FL 33138 City: State: Zip: Tenant/Lessee Name: Phone#: Email: OCASSOLA@GIROSOL.COM CONTRACTOR: Company Name: PRITTSSINC Phone#: 954-733-7663 PO BOX 5187 Address: City: FORT LAUDERDALE State: FL Zip: 33310 Qualifier Name: MICHAEL S. FRITTS SR Phone#: State Certification or Registration #: CCC1328313 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 16;000 Type of Work: ❑ Addition I I Alteration Square/Linear Footage of Work: El New Description of Work: ^S}°I, ll ,1'13 &e.- e-^" as QSO K OA �SoPcL. aso fR 6S 14, e..". Specify color of color thru tile: S o0 Er Repair/Replace ❑ Demolition b4Sc S\p. CoNC.t-"1 Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Training/Education Fee $ CCF 0C1.ibRli^. ,If 36Ot d�'♦,1 YMk!. ♦ 6� .rr chlu+ V$k A :d 4m ESSBSS 11 to na:telrino;r y. ; ,c tvIleKa "'TCO/;GCS:' nnA'O isaL"s),+ MS_ '4440 DBP, 4 Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledgedabefore me this The foregoing instrument was acknowledged before me this og ' day of 412./ �C. , 20 % 7 . , by 28 day of APRIL , 20 17 , by �/�0pit.4. 64650/ MICHAEL S. PRIITS SR ,who is personally own to , who is personally known to CONTRACTOR me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PU 1>sC: Sign: Print: Seal: ********** r op ate— — — JOSE J. GIRALDO Nobly Public • State of Aortal Commission I FF 228273 * Ily4011141 Atoka Sri al*24 NIMIONno 1 Assn. APPROVED BY (Revised02/24/2014) /7 identification and who did take an oath. NOTARY PUBLI/ Sign: Print: Seal: s NNIE B ;:• Air gr Ile al , ua Commission # FF 245157 My Comm. Expires Oct 21, 2019 ,'FO ,,, Bonded through National Notary Assn. A' .. ************************************************************* Plans Examiner Structural Review Zoning Clerk A. TOMASSI ROOF TESTING, INC. Testing * Management * Design Specifications * Litigation * Quality Assurance * Consulting June 5th, 2017 File # 1331-17 Mr. Michael Pritts Pritts, Inc. PO Box 5187 Fort Lauderdale, Florida 33310 Project Name: : - •Ia residence, ' 25 N. Bayshore Drive, Miami Shores, Fl. 33138 Flood Test Locatio Terrace Deck Permit #: RF -5-17-1262 Total Deck Area: - 2, DECK TYPE: ximately WATERPROOF/ROOF SYSTEM: Soprema Modified Bitumen System (Noa # 16-0229.05 Page 15 of 74. One (1) ply of Sopralene Flam 250 Base sheet torch applied over a primed concrete deck followed by one ply of Sopralene Flam 250 FR GR torch applied. DESIGN CRITERIA: Flood Test is based on ASTM D 5957 Standard Guide for Flood Testing Horizontal Surfaces. A drain plug was installed at the internal drains. The deck was then flooded with a garden hoses to a minimum depth of 3" inches. Water level was checked periodically for a continuous 48-60 hours. Conclusion: The test was performed on 6-2-2017 at 10 am and concluded 60 hours later on 6-5-17 at 10:00 am. The Main Terrace Deck was flooded with 3" inches of water. It was observed and documented that the water level remained at 3" and no leaks were present in the residence space, immediately below the terrace deck. This Test was done in accordance with ASTM D 5957 Standard Guide for Flood Testing Horizontal Surfaces. We appreciate the opportunity to be of service. Various information w f you have any questions regarding these findings, please call. Anthony Tom. si QA Manager : Certified Lab Contact 5451 NW 24th Street, Margate Fl. 33063 - Tel. 954 - 979-1180 Fax. 954 - 979 - 1182 Metro - Dade County NOA—Testing Agency Certification # 12-0710.03 Revises # 03-0317.03 A. TO.MASSI ROOF TESTING, INC. Testing * Management * Design Specifications * Litigation * Quality Assurance * Consulting June 5th, 2017 File # 1331-17 Mr. Michael Pritts Pritts, Inc. PO Box 5187 Fort Lauderdale, Florida 33310 Project Name: Flood Test Location: Permit #: Total Deck Area: DECK TYPE: R c l3-zro2 Cassola Residence, 9325 N. Bayshore Drive, Miami Shores, Fl. 33138 Terrace Deck RF -5-17-1262 2,500 sf approximately Concrete WATERPROOF/ROOF SYSTEM: Soprema Modified Bitumen System (Noa # 16-0229.05 Page 15 of 74. One (1) ply of Sopralene Flam 250 Base sheet torch applied over a primed concrete deck followed by one ply of Sopralene Flam 250 FR GR torch applied. DESIGN CRITERIA: Flood Test is based on ASTM D 5957 Standard Guide for Flood Testing Horizontal Surfaces. A drain plug was installed at the internal drains. The deck was then flooded with a garden hoses to a minimum depth of 3" inches. Water level was checked periodically for a continuous 48-60 hours. Conclusion: The test was performed on 6-2-2017 at 10 am and concluded 60 hours later on 6-5-17 at 10:00 am. The Main Terrace Deck was flooded with 3" inches of water. It was observed and documented that the water level remained at 3" and no leaks were present in the residence space, immediately below the terrace deck. This Test was done in accordance with ASTM D 5957 Standard Guide for Flood Testing Horizontal Surfaces. We appreciate the opportunity to be of service. Various information j@v�r�dk7y..?-�;•ntractor. If you have any questions regarding these findings, please call. Anthony Tom ; ssi QA Manager & Certified Lab Contact 5451 NW 24th Street, Margate Fl. 33063 - Tel. 954 - 979-1180 Fax. 954 - 979 - 1182 Metro - Dade County NOA—Testing Agency Certification # 12-0710.03 Revises # 03-0317.03 Project Address Miami Shores Village 10050 N.E. 2nd Avenue N Miami Shores, FL 33138-0000 Phone: (305)795-2204 Permit issue Date: 5/9/2017 Permit No. RF -5-17-1262 Permit Type: Roof Work Classification: Flat Permit Status: APPROVED Expiration: 11/05/2017 Parcel Number Applicant 9325 N BAYSHORE Drive Miami Shores, FL 33138- 1132050270540 Block: Lot: OMAR CASSOLA A. Owner Information OMAR CASSOLA Address 9325 N BAYSHORE DR MIAMI SHORES FL 33138-2950 Contractor(s) PRITTS INC • Phone Cell Phone (954)733-7663 (954)325-1066 Phone (305)206-2754 Cell Valuation: $ 75,000.00 Total Sq Feet: 2500 Type of Work: Re Roof Additional Info: INSTALLING SUPREMES 250 BASC SHEET Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $45.00 $4.50 $4.50 $15.00 $300.00 $9.00 $60.00 $438.00 Pay Date Pay Type Invoice # RF -5-17-63951 05/09/2017 Credit Card 05/09/2017 Check #: 8727 Amt Paid Amt Due $ 50.00 $ 388.00 $ 388.00 $ 0.00 Available Inspections: Inspection Type: Tin Cap Final Roof Review Roof Roof in Progress Renailing Affidavit In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction d zoning. Futhermore, I authorize the above-named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy May 09, 2017 Date May 09, 2017 1 • ROOF ASSEM9I IIES'ANDR OOFT P STRUCTURES r(� / /4(✓ •"fn t 4 t. • Florida Building Code 5th Edition (201 High -Velocity Hurricane Zone Uniform Permit Applicati Section A (General Information) Master Permit No. Process No. Contractor's Name PRITTS INC Job Address 9325 N BAYSHORE DRIVE 1 1 1 1 1 1 1 ROOF CATEGORY I RECEIVED ❑ Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles 1 MAY 0 9 2017 0 Asphaltic Shingles 0 Metal Panel/Shingles 0 Wood Shingles/Shakes I .... i 0 Prescriptive BUR -RAS 150 4,. •• ROOF TYPE .••• • . • • • • •r • • • 1416o New roof 0 Repair 0 Maintenance ❑ •Reroofin •••••i • g 0 Recovering ROOF SYSTEM INFORMATION •••••• •••••• ••••• �•••;� Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) Total (SF) •' • • • • • • OS00 NA: • • ••:••• ..••I• Section B (Roof Plan)• • • •t Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers anti overflow draics..loavde din1eft'•t• sions of sections and levels, clearly identify dimensions of elevated pressure zones and locationbf pg a ets. • ...0 •• • ••• • •1. • • 0 APPROVED y. a „i 11 11111111111111111111111111111111111E111111111111111•1111111111 NEER Ell •• 11111111:11111111111111111111111111111111111Iillfli1111111M1111111=111111111=11M111,1111,11 H w 0 CD Z O or 41.1 ZMP FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliczer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Soprie i 14 Product Approval No.: I Design Wind Pressures, From RAS 128 or Calculations: 1 P1: ". o/ o P2: ` '14 P3: " l Top Ply Fastener/Bonding Material: Surfacing: 41/1 Fastener Spacing for Anor/Base Sheet Attachment: Field: " oc @ Lap, # Rows — @ " oc Perimeter: " oc @ Lap, # Rows — @ _" oc Corner: " oc @ Lap, # Rows @ oc Number of Fasteners Per Insulation Board: Field Perimeter 1 1 1 1 1 1 1 1 1 1 1 ' 9 t �peciflc product • • ••.• • .P .... Illustrate Components Noted and Detailses Appliaabia. • • Woodblocking, Edge Terr iititt ort Stri I • Deck: 9,pp r+ flashing, 1 Type: �G�C L Continuous Cleat, Cant Strip, Base.flashing, Counteelashing, •1 • 1 Coping, Etc. •••• •••••• ••.. • Indicate: Mean Roof Height, Parl�pet48ight, HbAht of Base • Gauge/Thickness: Flashing, Component Material, f44tpti§l•Thickness, fastener 6w:66. Type, Fastener Spacing or Subrrli>rfl1 i facturers EleFails that 616.° • 1 Slope: Comply with RAS 111 and Chap;j 1L; "" 4,1 • • Anchor/Base Sheet & No. of Ply(s): •: . •. �• 1 Anchor/Base Sheet Fastener/Bonding Material: IG+tG • 1• • •: I • a� dia Fg G� 1 1 • 1 1 6d 146..)14,4-41‘ I if 35 I Max. Design Pressure,from th approvalsystem: �+ • • • . CO(V?••• --r Insulation Base Layer: 11:31. tcw G0 1 nn ,r 1 Base Insulation Size and Thickness: d %� 8 1 1 Top Insulation Layer: M;Sh Iv...) CO 1 Top Insulation Size and Thickness: .2X o 3 it 1 Top Insulatigf�Fastener/B nding M t rials t 1�ua '�t�� q.��GS� vG> Base Sheet(s) & No. of Ply(s): SOerecittle- 1 Base Sheet F stener/Bonding Material ot-th q fp).�� Base Insulation Fastener/Bonding, Material: �un k K Q141hI8.5.S 1 Ply Sheet(s) & No. of Ply(s): Nl/i FT. FT. Parapet Height 1 Qs° C) 1 Ply Sheet Fastener/Bonding Material: Top Ply: SOrCA,I er,t Fit." OSD FO, G R " 15.38 INTERNATIONAL CODE COUNCIL Mean Roof Height 1 1 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliczer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. Forensic Engineering Consultants, Inc. Project Name Project Address WIND UPLIFT PRESSURE CALCULATIONS Omar Cassola Residence 9325 North Bayshore Drive Miami Shores, FL - 33138 Report No.: ATRT-DP-17.016 Deck Substrate Concrete Mean Roof Height 35.0 Feet Configuration Low Slope Roof Area (Approx.) 2500 Sq.Ft. Category II Roof Width 23.0 Feet Exposure Condition D Perimeter Width 3.0 Feet Building Type Enclosed Parapet Height 1.0 Feet Base Wind Speed 175 mph Corner Zones 3' x 3' Each Slope V 0.0 Slope H 12.0 Slope Angle° 0.00 Uplift Pressures qZ = 0.00256 KZ Ke Kd V2 P = qZ (GCp - GCp;) • • qZ KZ KZt Kd V GCp GCp; •••• •• • • • • • •• •• • • ••• • 79.952 1.194 1.005 0.85 175 -1.00 0.18 • •Fuld• - 1.80 0.18 ••Perimeter•.•. - 2.80 0.18 •Corner ••••• • .• • • •• ••• ••.•.• Field P1 „n. -94.34 psf P1 asd -56.61 psf • Perimeter P2 u@ • . -158.31 psf P2 asd -94.98 psf • • • • ••• Corner P3 ult. -238.26 psf P3 asd -142.95 psf • • • ••• • System Design Pressures Field P1 -56.61 psf Perimeter P2 -94.98 psf Corner P3 -142.95 psf Proposed System Product Approval No. System Design Pressure Max. Calculated Uplift Pressure -142.95 psf ••• • • • •• These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. Any Miami -Dade County approved roof system over concrete decks with a system design pressure greater in magnitude than 142.95 psf may be used on the subject roof. The roof system must be installed in accordance with the Florida Building Code and the roof system manufacturer's recommendations. Sincerely For sic Engineering Consultants, Inc. . u R. N. Sailappan, P.E. 42411 Principal Engineer Florida Registration No. 46696 • Forensic Engineering Consultants, Inc. (CA # 8265), P.O. Box 970034, Boca Raton, FL - 33497 Ph (561) 901 8490 Fax (561) 218 3830 SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usyiI4 concealed prior to removing the existing roof system).• • •••• • • • • •• • • ••• • • • • •• • 4. / //-L _Exposed Ceiling: Exposed, open beam ceilings are where the underslue of the rJbf decking • can be viewed from below. The owner may wish to maintain the architecturaI•� eafance;4thergrore, • roofing nail penetration of the underside of the decking may not be acceptabie..T's provide IR option Sr: ". maintaining the appearance. • • . •• ••••• ••• .• • •••• •••••• ••••.• • .• • •. • 6. C Overflow scuppers (wall outlets): It is required that rainwater?1owAlf so that the roof is • • • • not overloaded from a buildup of water. Perimeter/edge wall or other roof exten'sion'may b?dticth6 • • discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install ovetfrow scuppers in cordance with the requirements of Sections R4402, R4403 and R4413. Owner/Agents Signature Date Contractor Signature /937..Y/v Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; .2G,-) D to e Dan From: michael pritts [mikeprittsroofing@yahoo.com] Sent: Monday, May 01, 2017 6:32 AM To: Dad Subject: Fwd: Fire Directory UL listing Sent from my iPhone Begin forwarded message: From: mmcclay@soprema.us Date: April 28, 2017 at 5:05:50 PM EDT To: mikeprittsroofing@yahoo.com Subject: Fwd: Fire Directory UL listing Mike, Please let me know if this works. Thanks Sent from my iPhone Begin forwarded message: From: "Patrick BLACK" <pblack@soprema.us> Date: April 28, 2017 at 4:54:17 PM EDT To: "Mike MCCLAY" <mmcclay@soprema.us> Subject: Re: Fwd: Fire Directory UL listing • • .... . • . .. . . ... • . . .. . • . . • • .... .... • . • . .... .... ... . . . . . .... .... • . . • .. . • . •• . . •. • . .. . ... . • • .. .. TGFU.R11436 - UL Class for the waterproofing/membrane system only. There is no UL rating for the overburden nor would we test for this. The tile topping is non-combustible anyway so you would not test the tile. Hope this helps. 24a. Deck: NC Incline: 1/2 Insulation (Optional): — UL Classified polyisocyanurate, glass fiber, rock wool, perlite, wood fiberbo DensDeck®, 1/4 in. min or Pittsburgh Corning "FOAMGLAS", any combination, any thickness except as fastened or adhered with hot roofing asphalt. NOTE: Classified base sheet below required when option Base Sheet (Optional): — One or more plies Type G1, G2, "Sopraglass 40", "Sopraglass 100", "Modic mechanically fastened or adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies "Elastophene Sanded", "Elastophene 180 Sanded", "Elastc "Sopralene 180 Sanded", "Sopralene 250 Sanded", or "Soprabase 5", mechanically fastened or adhere asphalt, or "Sopralene Flan) 180", "Elastophene Flam", or "Soprabase TG", mechanically fastened or h Membrane: — "Sopralene 180 FR GR", "Sopralene 180 FR GR 3.5", "Sopralene 250 FR GR," adhered v asphalt, or "Sopralene Flam 180 FR GR", "Sopralene Flarn 180 FR GR 3.5" or "Sopralene Flam 250 FR c place. 1 SOPREMA Patrick Black Te;hnical Support Coordinator 201 Ousdral Drive Wadsworth. OH 44281 Email: pblack atsoprema.us Office. 330 334.0066 Ext. 2284 Office: 330.331.3033 Fax: 330.334.7903 Cell: 330.405.0274 www.soprema.us Coridenttality Notice: This nriassaps, is a private oommunicatjor. It might contain oordident.ai 1 information. If you ere not the intended recipient please. do not read. copy. or u:.: it, and do I not disclose it b others. Please rrilify the sender of the delivery error by :epMng to This message and then delete it from your system, Thank You. Mike MCCLAY---04/28/2017 04:22:48 PM ---From: Mike MCCLAY/SALES_US/SOPREMA To: Patrick BLACK/SALES_US/SOPREMA@SOPREMA, From: Mike MCCLAY/SALES_US/SOPREMA To: Patrick BLACK/SALES_US/SOPREMA@SOPREMA, Date: 04/28/2017 04:22 PM Subject: Fwd: Fire Directory UL listing ••• • • • • • •••• • • • • •• • • ••• • • • • • •• • • • • • •••• •••• • • • • •••• •••• • •• •• •• • • • •••• • • • • • • • • • • • • • • • • • • • •• • ••• • • • • • Pat, I am not near a computer right now as I am at the AIA national trade show. Is this something you could look up for me? Thank you, Mike Sent from my iPhone Begin forwarded message: From: "michael pritts" <mikeprittsroofing@yahoo.com> Date: April 28, 2017 at 12:27:00 PM EDT To: mmcclay@soprema.us, "Steven McCray" <Steven.e.mccray !,gmail.com> Subject: Fire Directory UL listing Mike, I need UL listing on assembly asap. Thank you 2 MIAMI.3ADEj COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) SOPREMA, Inc. 310 Quadral Drive Wadsworth, OH 44281 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.tov/economv .... This NOA shall not be valid after the expiration date stated below. The Miami-Dade,Couilty • • • Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than 1% TarIi Dade. ... County) reserve the right to have this product or material tested for quality assurance•pxrases. It's • • •• this product or material fails to perform in the accepted manner, the manufacturer wi$l•iiitttt the • expense of such testing and the AHJ may immediately revoke, modify, or suspend theitt•of such. • • • •• product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if its • • is determined by Miami -Dade County Product Control Section that this product or nivierj lfails to• : • meet the requirements of the applicable building code. • • • . This product is approved as described herein, and has been designed to comply with the Fldrida Etuiildigg Code including the High Velocity Hurricane Zone of the Florida Building Code. . . • ... . DESCRIPTION: SOPREMA Waterproofing Systems • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-0715.02 and consists of pages 1 through 74. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 1 of 74 • 4 ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: Roofing Waterproofing Systems SBS Concrete, Steel, Lightweight Concrete -572.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D6163 Product Dimensions Colvent TG 39" x 49' (1.5 sq.) Colvent 180 TG Colvent Flam TG Colvent Flam 180 TG Colvent SA Elastophene Sanded Colphene Sanded Elastophene Sanded 3.0 Elastophene PS Elastophene PS 3.0 MIAMI•DADE COUNTY APPROVED 39" x 33' (1 sq.) 39" x 49' (1'h sq.) 39" x 33' (1 sq.) ASTM D6164 ASTM D6163 ASTM D6164 39" x 49' (1.5 sq.) ASTM D6163 39" x 49' (1'h sq.) ASTM D6163 39" x 49' (1'h sq.) ASTM D6163 39" x 33' (lsq.) ASTM D6163 39"x49'(1'/zsq.) ASTMD6163 39" x 49' (1'h sq.) ASTM D6163 Product Description Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. Non -woven polyester reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. •••• Fiberglass reinforced, modif>.ed bitumen •••••• membrane with a burn -off filly uhdgrside and.. • plastic film •surface. ' • • •• Non -woven polyester reinforced 'modified • bitumen membrane with a burf'tffffilm "" underside and a plastic film sill -face. Appliedb' heat welding. • • • • • Fiberglass reinforced, modifiiathynen membrane with 1" wide factcOy applied self- • adhering strips on back side • • Fiberglass reinforced modifiecbbitumen • • • • membrane sanded on both sides. Applied in hot' asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripped. Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 2 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastophene SP 2.2 39" x 49' (11/2 sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Colphene SP 2.2 39" x 49' (11/2 sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Elastophene SP 3.0 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding. Colphene SP 3.0 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen •• • • • membrane with a plastic buri2-off film on the • • • bottom and sanded on the top.' Apliied by he3P : • welding. • • • Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modifiedt timen ••• ,• • • membrane covered on both slttpm' th a pl'astig.' burn -off film. Applied by heat welding. . •.. • • Elastophene Flam 39" x 49' (1'/2 sq.) ASTM D6163 Fiberglass reinforced modified'titumen • • • • 2.2 membrane covered on both sides, vh a plastic • burn -off film. Applied by heat welding. ' • • Sopralene 180 39" x 49' (11/2 sq.) ASTM D6164 Non -woven polyester reinforced i& dified• • .•• • • • Sanded 2.2 bitumen membrane sanded on doth sides. • •' • Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 180 39" x 49' (11/2 sq.) ASTM D6164 Non -woven polyester reinforced modified Sanded bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Colphene 180 39" x 49' (1'/2 sq.) ASTM D6164 Non -woven polyester reinforced modified Sanded bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Sopralene 180 PS 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the top and sanded on the bottom. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 39" x 48' (11/2 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 PS bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. MIAMI•DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 3 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Sopralene 180 39" x 33' (1 sq.) PS 2.2 Colphene 180 PS 39" x 48' (1'/2 sq.) Elastophene 39" x 33' (1 sq.) LS FR GR Elastophene GR 39" x 33' (1 sq.) Elastophene 39" x 33' (1 sq.) FR GR Elastophene 39" x 33' (1 sq.) Flam LS FR GR Elastophene Flam GR Elastophene Flam FR GR Elastophene Flam FR+ GR Sopralene 180 Sanded Sopralene 250 Sanded MIAMI•DADE COUNTY APPROVED 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 26' (3/4 sq.) 39" x 33' (1 sq.) 39" x 26' (3/4 sq.) Test Specification ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the top and sanded on the bottom. Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping.. Fiberglass reinforced modifigid bit -ripen • • • • membrane with fire retardants,' Banded on tfie •. • bottom and mineral granules on tte top. Applied in hot asphalt, cold adhesive ofpon stripping. Fiberglass reinforced modifidtj.bitythen membrane with fire retardants,.a plastic barn-eff film on the bottom and mineral•gpanules on'the • top. Applied by heat welding, . Fiberglass reinforced modifie l bitumen • membrane with fire retardant;Aprastic bt r i;off film on the bottom and mineral granules on the.; top. Applied by heat welding. Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 4 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Sopralene 180 39" x 33' (1 sq.) ASTM D6164 SP 3.5 Colphene 180 SP 3.5 39" x 33' (1 sq.) ASTM D6164 Sopralene 180 39" x 33' (1 sq.) SP 3.0 Sopralene 250 SP 39" x 33' (1 sq.) Soprafix 39" x 33' (1 sq.) Soprafix Base 622 39" x 33' (1 sq.) ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 Soprafix Cap FR -651 Sopralene Flam 180 Colphene Flam 180 Sopralene Flam 250 MIAMI•DADE COUNTY APPROVED 39" x 33' (1 sq.) ASTM D6163 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding. Non -woven polyester reinforced modified.... • bitumen membrane with a plsstiiburn-of*ffrlrn on the bottom and sanded on tine tap. Apglfed55t heat welding. • Non -woven polyester reinforced modified bitumen membrane sanded otul;gtfisides.• • . . • • Non -woven polyester reinforil.rppdified .. bitumen membrane sanded osi•gotla sides.. • ••• • • Fiberglass reinforced modified b;tu2nen • membrane with fire retardants and a plastkbu- off film on the bottom and m3nerat franules on • the top. Applied in cold adhesive or by heat • • welding. Non -woven polyester reinforced SBS modified bitumen membrane, both sides covered with a plastic burn -off film, used as a base/ply. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced SBS modified bitumen membrane, both sides covered with a plastic burn -off film, used as a base/ply. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced SBS modified bitumen membrane, both sides covered with a plastic burn -off film. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 5 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Sopralene 180 39" x 33' (1 sq.) ASTM D6164 Non-woven polyester reinforced modified FR GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn-off film). Colphene 180 39" x 33' (1 sq.) ASTM D6164 Non-woven polyester reinforced modified FR GR bitumen membrane with fire retardants and a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic bum- off film). Sopralene 250 39" x 33' (1 sq.) ASTM D6164 Non-woven polyester reinforced modified FR GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon.. • stripping (after removal of piastiabum-oNKitn). Colphene 250 39" x 33' (1 sq.) ASTM D6164 Non-woven polyester reinforce modified* •••; FR GR bitumen membrane with firettti'ants and sa • sanded bottom and a minerar Vanu'es top. • Applied in hot asphalt, cold mind adhesiv•;.qt• ribbon stripping (after removAj j f.plastic burp-. off film). •.: TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 TestProduct Product Dimensions Specification Description Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 250 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 250 FR GR bitumen membrane with fire retardants and a Sopralene Flam 180 FR+ GR 39" x 33' (1 sq.) ASTM D6164 Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 250 FR+ GR Soprastar Flam Soprastar Stick 39" x 33' (1 sq.) ASTM D6162 39" x 33' (1 sq.) ASTM D6163 Sopralene Stick 39" x 33' (1 sq.) ASTM D6164 Colphene Stick 39" x 33' (1 sq.) ASTM D6164 Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Antirock Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Stick Elastophene Stick 39" x 33' (1 sq.) ASTM D6163 FR GR MIAMI•DADE COUNTY APPROVED plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or rilaboin, stripping (after removal of plastio burn -otic €4m). Non -woven polyester reinforeecT niodifieil• : • : bitumen membrane with firefelfdants a 1?lastie burn -off film on the bottom tritl' uneral granules on the top. Applied by heati:11Iag or riip . • stripping (after removal of pJ c, urn -off fiyrp). Polyester reinforced SBS mp4il>edbitum'ec:... membrane with a plastic burefffflm on the. bottom side and a reflective white top sui fm.:. Applied by heat welding. : . •. Fiberglass reinforced SBS modifies bitumen. membrane with a release film covered self - adhering bottom side and a reflective white top surface. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Non -woven polyester reinforced modified bitumen membrane with a sanded underside and surfaced with colored granules. Self -adhered, polyester reinforced membrane with a release film on the bottom and a plastic burn -off film on the top. Self -adhered, fire -rated, granule surfaced, fiberglass reinforced membranes. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 7 of 74 TRADE NAMES Product Sopra G Modified Sopra G Soprabase Soprabase S Soprabase TG Elastophene HS OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D4601 Dimensions 39" x 108' (3.5 sq.) 39" x 108' (3.5 sq.) 39" x 99' (3 sq.) 39" x 65' (2 sq.) 36" x 65' (2 sq.) 39" x 66' (2 sq.) Sopra IV 36" x 180' (5 sq.) Sopra VI 36" x 180' (5 sq.) Elastophene HD ASTM D4601 ASTM D4601 ASTM D4601 ASTM D4601 ASTM D6163 ASTM D2178 ASTM D2178 39" x 33' (1 sq.) ASTM D6163 Soprastar Sanded 39" x 33' (1 sq.) Sopralene Flam 180 GR 3.5 Sopralene Flam 180 FR GR 3.5 ASTM D6162 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 Elastocol 500 various Elastocol Stick various ALSAN Flashing' 1.25 gallon pail or 3.75 gallon pail MIAMI•DADE COUNTY APPROVED ASTM D41 Proprietary Proprietary Product Description Fiberglass reinforced oxidized asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Fiberglass reinforced modified asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Oxidized asphalt, polyester reinforced, sand - surface base sheet. For use as a base/ply sheet only. SBS modified bitumen, polyester reinforced, sand -surfaced base sheet. For use as a base/ply sheet only. SBS modified bitumen, polyester reinforced, sand -surfaced base sheet. For use as a base/ply sheet only. ••••• Fiberglass reinforced modified bitumen ••••• membrane with fire retardants andsandeil tut •; both sides. Applied in hot aSplidlt,•cold adh'sie or ribbon stripping. Type IV, fiberglass reinforccT,• meoth surhece elii ply sheet used in multi -ply syitppAand cpmpjs with ASTM and UL Standards.' Aliplied Tia bet' asphalt or cold adhesive. • Type IV, fiberglass reinforced, smooth std, ply sheet used in multi -ply sIsteuts•and complies with ASTM and UL Standards Applied iri fiet asphalt or cold adhesive. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt or cold adhesive. Polyester reinforced SBS modified bitumen membrane with a highly reflective reinforcement film on top and sanded on the bottom. Non -woven polyester reinforced modified bitumen membrane with colored granules on top and film on the bottom. Non -woven polyester reinforced modified bitumen membrane with colored granules on top and film on the bottom. Asphalt primer. • Polymer based primer. One part polyurethane/bitumen resin, moisture cure compound for use as a flashing component. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 8 of 74 TRADE NAMES OF PRODUCTS Product Soprawalk Sopradrain Eco -Vent WR Sopradrain Eco -2 WR Sopramastic SP -1 High Velocity® Membrane Adhesive II (HVMA-II) Duotack FM Adhesive FM Adhesive (VOC) COLPLY Adhesive COLPLY Modified Adhesive Soprastar Adhesive MIAMI•DADE COUNTY APPROVED Dimensions 39" x 26' (3/4 sq.) 5 gallon pail, 55 gallon 1500 ml cartridges 5 gallon pail, 55 gallon 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail or 55 gallon drum 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail, 55 gallon drum or 350 gallon tote MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 TestProduct Specification Description Proprietary Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and mineral granules on the top. Applied by hot asphalt, cold adhesive or ribbon stripping. Polypropylene roof drain. Proprietary Proprietary ASTM C920, Type S, Grade NS, Class 50 Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Polypropylene roof drain. A solvent free sealant. Two part elastomeric urethane adhesive. • • •••• • Two part elastomeric urethan8 That'll adhesiv$'; • •• • • Elastomeric bitumen based caldadhesive... • • • • •41•• •••• • •• • • • • • ..•.• •••• Elastomeric bitumen based cpjd.11 iesive. • • • • • • • • • • • Polymer modified cold process membrane • • • . adhesive. Elastomeric bitumen based cold adhesive. Elastomeric bitumen based cold adhesive. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 9 of 74 APPROVED INSULATIONS: Product Name STYROFOAM High Load 60 Insulation STYROFOAMTM PLAZAMATETM SECUROCK Gypsum -Fiber Roof Board Ultra -Max Sopra-ISO x, Sopra-ISO r, Sopra-ISO s M -Shield Sopraboard ACFoam-II ISO 95+ GL H -Shield DensDeck, DensDeck Prime MIAMI•DADE COUNTY APPROVED TABLE 2 Product Description Extruded Polystyrene Insulation, Type VII Extruded Polystyrene Insulation, Type VII Gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Mineral fortified asphaltic cored coverboard Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Manufacturer (With Current NOA) The Dow Chemical Co. The Dow Chemical Co. USG Corp. RMax Operating, LLC SOPREMA, Inc. SOPREMA, Inc. ...• .SOPREMA'kV. • • . . . • At1as�Qofing Co rogation Firestone Buildin .Products . * pany, Ikfr • • Iit►Dte :Panels LJ . .... .... Georgia gRacific Gypsum LLC • • . . •. . . ••• . NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 10 of 74 • • APPROVED FASTENERS: Fastener Number Product Name 1. SOPREMA #14 Fasteners 2. SOPREMA #14 MP Fastener 3. SOPREMA #15 HD Fastener 4. SOPREMA 2" Seam Plate 5. SOPREMA 2.4" Seam Plate 6. SOPREMA 3" Round Insulation Plate 7. SOPREMA 1.7 in. Base Sheet Fastener 8. CR Base Sheet Fastener (1.2" or 1.7") 9. OMG Heavy Duty 10. OMG 3" Galvalume Steel Plates 11. Dekfast Galvalume Steel Hex Plates 12. Dekfast Galvalume Steel 3" Round plates 13. Dekfast 14 14. FM -90 15. Trufast 3" Metal Insulation Plates 16. Trufast #14 Stainless Steel HD Fasteners 17. Trufast #14 HD Fastener 18. Trufast #15 EHD Fastener 19. Trufast 2" Barbed Metal Seam Plate 20. Trufast 2.4" Barbed Metal Seam Plate MIAMI•DADE COUNTY APPROVED TABLE 3 Product Description Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Insulation fastener for wood, steel and concrete. Insulation and membrane fasteners Stress plate Galvalume steel stress plate Stress plate Base ply fastening systems for lightweight concrete decks Galvanized fastener for base sheet attachment for gypsum and lightweight concrete. Insulation fastener for wood, steel and concrete. Galvalume stress plate. Galvalume steel plate Galvalume steel plate. Insulation fastener Base ply fastening systems for lightweight concrete decks Galvalume steel plate Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Stress plate Galvalume steel stress plate Manufacturer Dimensions (With Current NOA) SOPREMA, Inc. Various Various Various 2" diameter 2.4" Round 3" diameter SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. 2.7" head& . SOPI 6MA,•Inc. . 1.7"long ••• . ... •1.125" thitit•: • • OMfP, Ine. • •• • .... •... Various O14G, Jc. •• •• .•.. • 3" round : 01MIG •• • 2'/s" x 3 'i4' • SFS frith, $c. 3" round SFS Intec, Inc. Various 2.7"headx 1.7" long 3" round Various Various Various 2" diameter 2.4" Round SFS Intec, Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 11 of 74 • . • . • • . • . • • APPROVED SURFACING/COATING OPTIONS: TABLE 4 Manufacturer Application System Number 1. 2. 3. Generic Generic SOPREMA, Inc. 4. Karnak Corporation 5. SOPREMA, Inc. 6. Thermo Manufacturing Systems, LLC 7. Quest Construction Products LLC dba United Coatings 8. Insulating Coatings Corporation Henry Company 9. National Coating Corp. 10. Generic Gravel applied at 401bs.bs/sq., adhered with flood coat of asphalt at 60 lbs./sq. Slag applied at 300 lbs./sq., adhered with flood coat of asphalt at 60 lbs./sq. Gravel applied at 400 lbs./sq., adhered with COLPLY Adhesive, FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 4 gal./sq. Karnak #97 Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal./sq. Cural Aluminizer applied at an application rate of 2 gal./sq. Super Prep Roof Coating applied in two coats at an application rate of 1.5 gal./sq./coat. •••• .. Roof Mate Coating, applied in one base coatat mate of 1.S g' 1./sq., and one finish coat at a rate of 1.5 gal./sq. •• ••• . • Astec 2000 Finish Coat applied in two base coatrat a rate of 0.75 gal./sq./coat and two finish coats at a rate ofb i gal./sqf os1..' • HE280DC White Elastomeric Roof Coating pppligel in two omits at an application rate of 1 gal./sq./coat. . Acryshield® A500 applied in two coats at an'ap• plieation 0te 44.1 gal./sq./coat. ' .• .• . Semi -ceramic coated colored granules. TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Product Exterior Ceramic Tiles Portland Cement Concrete Pavers Wausau Lok -Down Paver Lok -Down Tab Terra Stand Pedestal MIAMI•DADE COUNTY APPROVED Dimensions 12" x 12" x '/z" Various 12"x 12"x 1" 24"x24"x 2" Base: 6.5" square plate Top: 5.8" square plate 5" round core Test Specification ASTM C56 & ANSI A137.1 ANSI A118.1 ASTM C936 ASTM C936 Proprietary Product Description Ceramic plaza deck walking tiles, 5% water absorption max. A thin -set Portland based mortar formulated for ceramic tile installation. high density concrete pavers 8000 psi Min. Compressive strength, 5% water absorption SBR rubber tab used to support pavers to stand. Proprietary Copolymer polypropylene stand. •.. . .. •• Manufacturer Generic Generic Generic Wausau Tile, Inc. Wausau Tile, Inc. Wausau Tile, Inc. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 12 of 74 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories, Inc. Dynatech Engineering Corp. Exterior Research & Design, LLC Trinity I ERD MIAMI•DADE COUNTY APPROVED Test Name/Report FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4454 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 UL 790 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM D6163 Physical Properties ASTM D4798 & TAS 110 ASTM D6164 ASTM D2178 ASTM D4601 ASTM D6163 ASTM D6162 ASTM D6163 ASTM D2178 ASTM D4601 ASTM D6163 ASTM D6164 ASTM D6164 Test Identifier 1W8A1.AM 1Z3A6.AM 2DOAO.AM 2B8A4. AM 1D7A4.AM 3026028 3028631 3029098 3025185 3017614 3023749 3022038 3045101 3002351 797-07582-267 797-03385-267 RR201064 : .•. 3044801 3049322 3045734 3024594 R11436 10.94.27 2491-04.95 .. . Date 07/15/93 04/27/95 08/15/97 07/02/97 11/09/98 05/25/06 08/09/07 10/25/07 05/22/07 02/27/06 09/28/06 04/05/06 11/05/12 02/28/03 08/15/12 11/45'/22 •. 05/01725' 02/7(11.! • 01/17/14 .... 04/04112. 05/1.946• • 06/181 le.• . ... . . .. • . . . 10/27/94 • O1+96%. 02/11/97 04/15/97' • 08/15/97 10/19/02 09/02/03 10/03/03 12/23/04 04/18/07 11/02/07 04/06/10 06/01/10 06/07/12 11/17/10 08/26/14 06/07/12 07/07/14 03/14/13 12/12/11 12/12/11 03/14/13 03/14/13 03/14/13 . . 2003.02.97-1 2003-2.04.97-1 2002.07.97-1 2755.09.02 2761.09.03 2761.10.03-2 2760.12.04-R1 2777.09.05-R2 S6740.11.07 S10950.04.10 S11440.06.10 S11440.01.11 -R1 S11440.11.10-4 S11440.11.10 -3-R2 S11440.12.10 -1-R1 S32700.12.10 -R2 S35860.09.12 -R1 S35860.12.11-1 S35860.12.11-2 S35860.05.12 -1-R2 S35860.05.12 -2-R2 S35860.05.12 -3-R1 .. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 13 of 74 Test Agency Trinity I ERD IRT of S. Florida, Inc. ITS / Warnock Hersey PRI Construction Materials Technologies, LLC Atlantic & Caribbean Roof Consulting Intertek 1 Architectrural Testing MIAMI•DADE COUNTY APPROVED Test Name/Report TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 Physical Properties ASTM D6164 ASTM D6164 ASTM D6506 ASTM D6162 ASTM D6164 ASTM D6164 TAS 117 (B) TAS 114 ASTM D5147 ASTM D1644/D2196 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 TAS -138 ASTM D3019 Physical Properties TAS 114 Physical Properties Test Identifier S35010.10.10 -R1 S47170.08.14-1 S47300.08.14-1 S47300.08.14-2 SC5190.08.14 543400.08.14-4 543400.08.14-5 S43400.08.14-6 S43400.08.14-7 543400.09.14-9 S45890.09.14 S44110.08.14-5 S35860.05.12 -2-R3 S45010.02.14 532700.12.10-R2 S44220.09.14 -7C S44110.01.15 -4A -R3 S32840.06.10 -R1. • . . . 01-002 • • • Date 08/26/14 08/25/14 08/19/14 08/19/14 08/19/14 08/26/14 08/26/14 08/26/14 08/26/14 09/02/14 09/02/14 08/29/14 08/29/14 02/07/14 07/07/14 09/02/14 05/01I1L 12/11.14.' 01/2170!•: .. . 05/27/93 .... SOP -049-02-01 *. • •• • 05/31111. • SOP -043-02-0102/37/1g• SOP -042-02-01 • •' • •' 02/27'/I P. SOP-041-02-01 . . . 02/27/12 SOP -040-02-01 ' . 02474 2: • SOP -010-02-01.03 • . •' : 07/14(1 . SOP -050-02-01 03/04/15.: ADCO-001-02-01 06/16/13 ACRC# 08-0359 06/20/08 F0856.01-106-18 05/13/16 NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 14 of 74 APPROVED APPLICATIONS: Membrane Type: SBS Deck Type 3I: Concrete, Insulated Deck Description: Terrace/Plaza Deck, Planter, Traffic System Type A(1): Membrane adhered directly to primed concrete deck. Insulation adhered under surfacing for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Substrate Preparation: All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Primed with ASTM D 41 primer applied to top of composite board or top of cover board in insulation assembly. Base/Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. •••• Membrane Elastophene Flam LS FR GR, Elastophene Flam FR GR, lageghene Prang • • FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR' Soptalene J aif 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 18x•11 + GR, • • • nrr_alen oe Flam 250ZR GR, Colphene Flam 250 FR GR or�y4ialene F��m• 250 FR+ GR, torch -applied. • •••• • ••••• • Integrity Test: Required, and shall be performed in accordance with AS1111 » 957 bT it •• approved lab. Water maybe maintained for a period longe?th5ft 24 houtS'if • required. . . . One or more layers of any of the following insulations. Insulation Layer . . • • . • • .• •• • . • Insulation Fasteners, • • Fasten er : • . (Table 3) Density/fte• SiTYROFOAM High Load 60 Insulation, STYROFOAMTM PLAZAMATETM Minimumimum 1.5' t lc N/A N/A Note: All layers of insulation shall be adhered with Duotack adhesive beads spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation as the final membrane substrate. Inspection: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards and traffic surfacing. All defects observed shall be corrected. Exterior grade ceramic plaza deck walking tiles (Minimum size of 12" x 12" and minimum %2" thickness) tiles shall be embedded into mud -set Portland Cement applied with a 1/4" minimum square notched trowel. Tiles should then be carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. -255 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 15 of 74 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. All work shall be performed by a Contractor licensed to do roofing/waterproofing and be a Manufacturer Trained 'Qualified Applicator' approved by SOPREMA. SOPREMA shall supply a list of approved applicators to the authority having jurisdiction. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') valuedf27,5 lbf., as tested in compliance with Testing Application Standard TAS 105. If the farenor value, as ?i td- • tested, are below 275 lbf. Insulation attachment shall not be acceptable. • • ` • • • •• • • •• • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachaaaeaat is based on a • • minimum fastener resistance value in conjunction with the maximum design value liated•within g••••• • specific system. Should the fastener resistance be less than that required, as determilied by the Baliltfig • • Official, a revised fastener spacing, prepared, signed and sealed by a Florida registernl'rbfessidnal". Engineer, Registered Architect, or Registered Roof Consultant may be submitted. iaidrevised fastener • spacing shall utilize the withdrawal resistance value taken from Testing Applicatioai Stttntards IAS 1.05 .,,.,:. and calculations in compliance with Roofing Application Standard RAS 117. . .• • 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these" att4s.: Fastener densities shall be increased for both insulation and base sheet as calculated in compliance wftfi Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. A non-skid surfacing is required for all pedestrian areas, plaza decks or balconies. 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 12. Required integrity flood testing shall be provided to the Building Official for review at time of final inspection. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 74 of 74 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade • • • • County) reserve the right to have this product or material tested for quality assurance put�oses. If this product or material fails to perform in the accepted manner, the manufacturer vbtll iflcur the : • • expense of such testing and the AHJ may immediately revoke, modify, or suspend tM use•of such• • • product or material within their jurisdiction. RER reserves the right to revoke this acrepAnce, if it. • • • is determined by Miami -Dade County Product Control Section that this product or malgrAl•fails fb. •.. • meet the requirements of the applicable building code. . • • This product is approved as described herein, and has been designed to comply with thh'F1'oiida Builcliny Code including the High Velocity Hurricane Zone of the Florida Building Code. •• • • • • DESCRIPTION: Soprema Modified Bitumen Roofing Systems over Concrete Delks,, • • MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.¢ov/economy .. • . . . LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state •• and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0603.07 and consists of pages 1 through 160. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 1 of 160 ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: Roofing Modified Bitumen SBS Concrete -525 psf. TRADE NAMES OF PRODUCTS MANUFACTU TABLE Product Sopra G Modified Sopra G Soprabase Soprabase S Sopra IV Dimensions 39" x 108' (3.5 sq.) Test Specification ASTM D4601 39" x 108' (3.5 ASTM D4601 sq.) 39" x 99' (3 sq.) ASTM D4601 39" x 65' (2 sq.) ASTM D4601 36" x 180' (5 sq.) ASTM D2178 Type IV Sopra VI 36" x 180' (5 sq.) Elastophene Stick 39" x 49' (1.5 sq.) Elastophene Flam 39" x 49' (1.5 sq.) Stick Sopralene Flam 39" x 49' (1.5 sq.) Stick Sopralene Stick 39" x 33' (1 sq.) MIAMI•DADE COUNTY APPROVED ASTM D2178 Type VI ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6164 RED OR LABELED BY APPLICANT: 1 Product Description Fiberglass reinforced oxidized asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Fiberglass reinforced modified asphalt base ... sheet for bonding or mechanically attachia to • • substrate. For use as a base/ply shlet only. • • • Oxidized asphalt, polyester reifif4ittd, sand-'. • surfaced base sheet. For use as abase/ply Vivi only. • •••• • • SBS modified bitumen, polyeStn1 forced . • • • sand -surfaced base sheet. For use as a base/ply sheet only. • .. 0 Type IV fiberglass reinforced:smgbth surfaced plysheet used in multi -ply systems and complies; with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Type VI fiberglass reinforced, smooth surfaced plysheet used in multi -ply systems and complies with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Self -adhered, sanded surfaced, fiberglass reinforced membranes. Self -adhered, sanded surfaced, fiberglass reinforced membranes. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 2 of 160 Test Product Product Dimensions Specification Description Colphene Stick 39" x 33' (1 sq.) ASTM D6164 Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Colvent SA 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied self - adhering strips on back side Colvent TG 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. Colvent 180 TG 39" x 33' (1 sq.) ASTM D6164 Polyester reinforced, modified bitumen membrane with 1" wide factory applied heat weld strips on back side. Colvent Flam TG 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied hea. • • • weld strips on back side and a pies* burn-pff. • . • film •surface. ' .. •• Colvent Flam 180 39" x 33' (1 sq.) ASTM D6164 Polyester reinforced, modifienAtumen ..,. TG membrane with 1" wide factori iiitied h • weld strips on back side and 4411s3S i burnoff.. • film surface. • •' • . • • • • • • Elastophene 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced modified%ittugen• Sanded membrane sanded on both sidgs. Applied I'hor • asphalt, cold adhesive or ribbon.stripping. • • • • •• Colphene Sanded 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 39" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced modified bitumen Sanded 2.2 membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 39" x 33' (lsq.) ASTM D6163 Fiberglass reinforced modified bitumen Sanded 3.0 membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripped. Elastophene HS 39" x 66' (2 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane with fire retardants and sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene PS 39" x 49' (1.5sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 3 of 160 Test Product Dimensions Specification Elastophene PS 3.0 39" x 49' (1.5sq.) ASTM D6163 Elastophene SP 2.2 39" x 49' (1.5 sq.) ASTM D6163 Colphene SP 2.2 39" x 49' (1.5 sq.) ASTM D6163 Elastophene SP 3.0 39" x 49' (1 sq.) ASTM D6163 Colphene SP 3.0 39" x 49' (1 sq.) ASTM D6163 Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Elastophene Flam 39" x 49' (1.5 sq.) ASTM D6163 2.2 Elastophene Flam 39" x 33' (1 sq.) ASTM D6162 HS Elastophene HS 62 39" x 33' (1 sq.) ASTM D6162 Elastophene 180 39" x 49' (1.5 sq.) ASTM D6164 Sanded MIAMI•DADE COUNTY APPROVED Product Description Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). ... • Glass reinforced modified bihrmeiu pembr • • with a plastic burn -off film on tie bottom and: F. sanded on the top. Applied bVheat welding ori ribbon stripping (after removal of%lastic bum;. off film). • Glass reinforced modified bits eri membrane • • • with a plastic burn -off film ori the bottom and • sanded on the top. Applied b%+ heat'ielding or . ribbon stripping (after removaj of plastic barn- • off film). • • Fiberglass reinforced modified bitumen • • • membrane covered on both sides with a plastic burn -off film. Applied by heat welding. Fiberglass reinforced modified bitumen membrane covered on both sides with a plastic burn -off film. Applied by heat welding. Woven fiberglass/polyester composite reinforced modified bitumen membrane with fire retardants and plastic burn -off film on both sides. Applied by heat welding. Woven fiberglass/polyester composite reinforced modified bitumen membrane with sanded surface on both sides. Applied in hot asphalt, cold adhesive. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 4 of 160 Test Product Product Dimensions Specification Description Colphene 180 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified Sanded bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 180 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified PS bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Colphene 180 PS 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene GR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on athe • • bottom and mineral granules pnlled in hot asphalt, cold adhesive of fibbbn striftr;g.: Elastophene LS FR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modifiedbii>*men • GR membrane with fire retardant,,•sand1d on 1 '• . bottom and mineral granules oti tYirs top. A1p" .ed in hot asphalt, cold adhesive rattan stripgipge • Elastophene FR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified4rit,en GR membrane with fire retardants' sanded on it bottom and mineral granules can the'top. Applied. in hot asphalt, cold adhesive or ribbon stripping..; Elastophene FR+ 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen GR membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen GR membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen LS FR GR membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding.. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen FR GR membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. MANMADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 5 of 160 Product Elastophene Flam FR+ GR Sopralene 180 Sanded Sopralene 250 Sanded Sopralene 180 Sanded 2.2 Sopralene 180 PS Sopralene 180 PS 2.2 Sopralene 180 SP 3.5 Colphene 180 SP 3.5 Sopralene 180 SP 3.0 Sopralene 250 SP Soprafix Base 610 MIAMI.DADE COUNTY APPROVED Test Product Dimensions Specification Description 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 39" x 26' (3/4 sq.) bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 39" x 26' (3/4 sq.) bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane sanded on both sides. • • • • • • Applied in hot asphalt or colt} adbesive. •' •' .. . . ..• 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinfor;eda 1ified• • • bitumen membrane with a plastic:burn-off flint on the top and sanded on the tettetti •"" • .... •••. 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforcad.modified • • • bitumen membrane with a sanded•b ttom anti: t • plastic burn -off film on the tor ft lied in hof asphalt, cold adhesive or ribbon stiffing. ' • • . • . . •• 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified • • • • •: bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. 39" x 30' (1 sq.) ASTM D6162 Composite reinforced modified bitumen membrane with a film surface. Applied by mechanical attachment. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 6 of 160 Test Product Product Dimensions Specification Description Soprafix Base 611 39" x 33' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a film surface. Applied by mechanical attachment. Soprafix Base 630 39" x 33' (1 sq.) ASTM D6162 Composite reinforced modified membrane with a film surface. Applied by mechanical attachment. Soprafix [S] 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane. Applied by mechanical attachment. Soprafix Base 612 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane. Applied by mechanical attachment. Soprafix [F] 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane. Applied by mechanic4l• • • attachment. • Soprafix Base 613 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforc8d madified. • • • • ; • • bitumen membrane. Applied.6), Mechanical' • • • attachment. .... • Soprafix [X] 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced Modified • • • • • • bitumen membrane. Appliedb?mechaniaal: • attachment. • • • Soprafix Base 614 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforc't;d modified• • • • bitumen membrane. Applied by meehanich • • • • attachment. •• Soprafix 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a 4 -inch or 5 -inch wide side lap with a plastic burn -off film on the bottom and sanded on the top. Applied by mechanical attachment. Lap heat welded or sealed with an approved cold adhesive. Soprafix Base 622 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a 4 -inch or 5 -inch wide side lap with a plastic burn -off film on the bottom and sanded on the top. Applied by mechanical attachment. Lap heat welded or sealed with an approved cold adhesive. Soprafix-e 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a 5 -inch wide side lap with a self -adhering compound and release film and sanded on the bottom and top surfaces. Applied by mechanical attachment. Lap self - adhered or sealed with approved cold adhesive. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 7 of 160 Test Product Product Dimensions Specification Description Soprafix Base 641 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a 5 -inch wide side lap with a self -adhering compound and release film and sanded on the bottom and top surfaces. Applied by mechanical attachment. Lap self - adhered or sealed with approved cold adhesive. Soprafix Cap FR- 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen 651 membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced SBS modified 180 bitumen membrane, both sides covered with a plastic burn -off film. Applied by heat welding or ribbon stripping (after removal of plastic • •. burn -off film).• ' . • ••Y• • • • • • Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforcta OS moth eel• i • 180 bitumen membrane, both sides covered with a, • • plastic burn -off film. Applied.b,yl3eat welding. • • or ribbon stripping (after rembygl cf plastic. • • • • • • burn -off film).• •• •• • • • • • Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforvii, • �s modified• 250 bitumen membrane, both side$ coVeled with a • plastic burn -off film. Applied by •hey t welding or ribbon stripping (after removalof'plastie • • . burn -off film). •' Sopralene 180 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Colphene 180 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Sopralene 180 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified FR+ GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). MIAMI RADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 8 of 160 • .• • • Test Product Product Dimensions Specification Description Sopralene 180 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified Ultra FR GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Sopralene 250 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Colphene 250 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbog• • • stripping (after removal of plpticiburn-offJ np. Sopralene 250 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforctel madified' • • Ultra FR GR bitumen membrane with fire •retardants a sanded bottom and a mineral granulesttp, Appliedi>;. hot asphalt, cold applied adhe 4IN pt libbers •.. stripping (after removal of plash bwrn-off filmj.• • Sopralene 250 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinfor eodom iified • •••.• FR+ GR bitumen membrane with fire iitattiaits a sanded • bottom and a mineral granules top.. Applies in hot asphalt, cold applied adhesive orribboti••. : stripping (after removal of plastic burn -off film7.• Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 GR bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 GR bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 GR 3.5 bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 9 of 160 Test Product Product Dimensions Specification Description Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR 3.5 bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforc ed modified ••••• 180 Ultra FR GR bitumen membrane with fire retardants a ptastit: burn -off film on the bottom Mailfieral gra$ule§ on the top. Applied by heat welding or ribbon stripping (after removal of ple.§tjc rn-off�`�j17L1' Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinfortedhiddified .••. 250 FR GRbitumen membrane with fire ietarciants a plastic • • burn -off film on the bottom aid mi eral granulgs • on the top. Applied by heat welding or ri1S13drf • • . stripping (after removal of plastic burn -off iiJm)r• • • Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified • • 250 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 250 Ultra FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR+ GR bitumen membrane with fire retardants a plastic . • . . . . . MIAMI•DADE COUNTY APPROVED burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 10 of 160 Product Sopralene Flam 250 FR+ GR Sopralene Flam Antirock Elastophene Stick FR GR Colphene FR GR Elastophene Stick HR FR GR Colphene HR FR GR Sopralast 50 TV Alu Sopralast 50 TV Alu Sanded Soprastar Flam Soprastar Sanded Soprastar Stick UNILAY MIAMI•DADE COUNTY APPROVED Dimensions 39" x 33' (1 sq.) Test Specification ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) various various 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq) 39" x 33' (1 sq.) ASTM D 6163 ASTM D 6163 ASTM D 6164 ASTM D 6164 ASTM D6298 ASTM D6298 ASTM D6162 ASTM D6162 ASTM D6162 ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Self -adhered, granule surfaced, fiberglass reinforced membranes. Self -adhered, granule surfaced, fiberglass reinforced membranes. Self -adhered, granule surfaced, polyester reinforced membranes.. "• •••• Self -adhered, granule surfaced3 polyester • •• • • • reinforced membranes. • • Fiberglass reinforced modifiedbLtumen sheeting. faced with aluminum foil. Applied by he.... welding of ribbon stripping (aftcrtemovatot • • plastic burn -off film). . • •• "" Fiberglass reinforced modified bi1uiLen sheeting• sanded on the bottom and faced IA aluminum foil. Applied in hot asphalt, cella adihesive'&. ribbon stripping. Polyester reinforced SBS modified bitumen membrane with a plastic burn -off film on the bottom side and a reflective white top surface. Applied by heat welding. Stabilized polyester mat reinforced SBS modified bitumen membrane with a sanded bottom side and a reflective white top surface. Applied by hot asphalt or cold adhesive. Polyester reinforced SBS modified bitumen membrane with a release film covered self - adhering bottom side and a reflective white top surface. Non -woven polyester reinforced modified bitumen membrane with fire retardants and surfaced with mineral granules. Applied by mechanical attachment, heat welding or ribbon stripping (after removal of plastic burn -off film). NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 11 of 160 Product Elastocol 500 Elastocol Stick Elastocol Stick Zero ALSAN FlashingTM ALSAN Polyfleece COLPLY Flashing Cement Soprawalk High Velocity® Insulation Adhesive III (HVIA-III) High Velocity® Insulation Adhesive III — Green High Velocity Insulation Adhesive PG Duotack Duotack Neo COLPLY Adhesive COLPLY Modified Adhesive COLPLY EF Adhesive Sopravap'r MIAMIDADE COUNTY APPROVED Dimensions various various Various 1.25 gallon pail or 3.75 gallon pail 4", 8" or 39" wide by 50' long 5 gallon pail 39" x 26' (3/4 sq.) 4 dual cartridges per carton 4 dual cartridges per carton 5 gal. or 50 gal. 5, 50 gallon pail 5, 50 gallon pail 5 gallon pail or 55 gallon drum 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail 45" x 133' Test Specification ASTM D41 ASTM D41 ASTM D41 Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Various Product Description Asphalt primer. Asphalt primer. Asphalt primer. One part polyurethane/bitumen resin, moisture cure compound. Non -woven polyester reinforcement used in the ALSAN Flashing system. Elastomeric bitumen based mastic compound. Non -woven polyester reinforced modified • • • . • bitumen membrane with a sanded bottom and • • mineral granules on the top. Applied by hpt •• •: asphalt, cold adhesive or ribbbh•stfiDping. •• • • Two part elastomeric urethane osrn adhesive.• • • •••• •••• • • •• •• • •• • •••• Two part elastomeric urethanf foan;adhes4ve.. • • • • • • •• • • ••• • •• •• Two part elastomeric urethane foam adhesive. Two part elastomeric urethane foam adhesive. Two part polyurethane foam adhesive. Polymer modified cold process membrane adhesive. Elastomeric bitumen based cold adhesive. Solvent free, polymeric adhesive. Self -adhering air/vapor barrier membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 12 of 160 APPROVED INSULATIONS: Product Name ACFoam-II, ACFoam-III ACFoam Composite ISO 95+ GL EnergyGuard Polyiso Insulation EPS XPS High Density Wood Fiberboard Perlite Insulation DensDeck, DensDeck Prime Sopra-ISO s, Sopra-ISO+ s M -Shield, M -Shield CG Sopra-ISO r, Sopra-ISO+ r Sopra-ISO x H -Shield, H -Shield CG ENRGY 3, ENRGY 3 25 PSI, ENRGY 3 AGF, ENRGY 3 CGF Ultra -Max, Multi -Max FA -3 SECUROCK Gypsum -Fiber Roof Board Structodek High Density Fiberboard Roof Insulation Fesco Board Sopraboard DEXcell FA Glass Mat Roof Board DEXcell Cement Roof Board MANMADE COUNTY APPROVED TABLE 2 Product Description Polyisocyanurate foam insulation Composite polyisocyanurate insulation board Polyisocyanurate foam insulation Composite polyisocyanurate insulation Type IX 1.8 pcf. Polystyrene Insulation Type IV 1.6 pcf. Polystyrene Insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Gypsum board High Density wood fiber insulation board Expanded mineral fiber insulation Mineral fortified asphaltic cored coverboard Gypsum board Cementitious insulation board Manufacturer (With Current NOA) Atlas Roofing Corporation Atlas Roofing Corporation Firestone Building Products Company, LLC GAF Generic Generic Generic Generic Georgia Pacific Gypsurp.1 C Spprgm, Inc..... .. . . ... SpptNW, Inc....' • stverha, Inc. • .... .... Sbpxema, Inc..... • Hunfe'r.raryels, L)vC. • •. .• .... JohnsMarbuille Corp.. RMax•Qper4ting, I,L . USG Corp. • • Blue Ridge Fiberboard, Inc. Johns Manville Corp. Soprema, Inc. National Gypsum Company National Gypsum Company NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 13 of 160 APPROVED FASTENERS: Fastener Number Product Name 1. Soprema #12, #14 & #15 Fastener 2. Dekfast 12, 14 & 15 HS 3. Dekfast Galvalume Steel Hex 4. Dekfast DekFlat Round Plastic Lock Plate 5. AccuTrac Hextra 6. OMG 3" Galvalume Steel Plate 7. OMG Flat Bottom Metal Plate 8. #12 Standard Roofgrip, #14 Roofgrip & #15 Roofgrip 9. CD -10 10. Fluted Nail 11. 3 in. Round Metal Plate 12. OMG Plastic Plate 13. Trufast #14 HD Fastener 14. Trufast #15 EHD Fastener 15. Trufast 3" Metal Insulation Plate 16. OMG Polymer Batten Strip 17. Dekfast Galvalume Steel 3" Round 18. Dekfast Coiled Batten Strip 19. Dekfast 2" Round Barbed Seam Plate 20. Soprema 3" Round Insulation Plate MIAMI•DADE COUNTY APPROVED Table 3 Product Description Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Insulation fastener Galvalume AZ50 steel plate Polypropylene locking plate. Insulation fastener for wood and steel. Galvalume stress plate. Galvalume stress plate. Insulation fastener. Insulation fastener. Insulation fastener. Galvalume AZ50 steel plate Polypropylene stress plate Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Galvalume AZ50 steel plate Modified polymer batten bar Galvalume AZ50 steel plate Batten bar Stress plate Stress plate Dimensions 2'/s" x 3 1/4" Manufacturer (With Current NOA) Soprema, Inc. SFS Intec, Inc. SFS Intec, Inc. 3" x 3 1/4" SFS Intec, Inc. OMG, Inc. 3" diameter 3" square 3" diameter 3.25" diameter OMG, Inc. • • • .•.• •• OMG, .:••• . • •...4MG, Ina.. ..•• •••• • •. • . . • • •.• •• ••.. .... RMG, Inc.. • • OMG, U.. •• . • . • OMG, Inc. • • . Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. 3" diameter Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. 3" diameter SFS Intec, Inc. SFS Intec, Inc. 2" diameter SFS Intec, Inc. 3" diameter Soprema, Inc. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 14 of 160 APPROVED FASTENERS: Fastener Number Product Name 21. Soprafix 2" SB Stress Plate 22. Soprafix 2-3/8" SB Stress Plate 23. Soprafix MBB -R 24. Soprema #12 DP, #14 MP, #15 HD Fastener 25. Trufast Flat Batten Bar 26. Trufast Recessed Batten Bar 27. #15 Roofgrip Large Head 28. Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed Plate 29. Trufast 2" Barbed Metal Seam Plate 30. Trufast 2.4" Barbed Metal Seam Plate 31. Dekfast IF -2 -SB 32. Soprema 2" Seam Plate 33. Soprema 3" Metal Installation Plate 34. Trufast 3" Recessed Metal Insulation Plate 35. OMG Heavy Duty 36. OMG 2-3/8" Barbed XHD Plates 37. Trufast 2.4" Scoop Seam Plate 38. Soprema 2.4" Seam Plates MIAMI•DADE COUNTY APPROVED Table 3 Product Description Stress plate Stress plate Metal Batten Bar Insulation and membrane fasteners Galvalume AZ55 steel batten bar Galvalume AZ55 steel batten bar with recessed holes Carbon steel fasteners used in steel, wood and concrete decks Galvalume AZ55 steel barbed plate Galvalume steel barbed plate Galvalume steel barbed plate Galvalume AZ55 steel plate Stress plate Stress plate Galvalume AZ50 steel plate Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Galvanized steel stress plate Galvalume steel stress plate Galvalume steel stress plate Dimensions 2" diameter 2-3/8" diameter Various 2-3/8" diameter 2" diameter 2.4" diameter 2" diameter 2" diameter 3" diameter 3" diameter Various 2-3/8" round 2.4" Round 2.4" Round Manufacturer (With Current NOA) Soprema, Inc. Soprema, Inc. Soprema, Inc. Soprema, Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. •••• • • • •• •••• • • . SF$ Intec,.Ines • • • • ••• • • ••• •... • E1,ltettloh, Bfinack.& U. S., Inoa • • • •Alt .nloh, Brinck.& Cq. U.S.•Inc. . SFS InteC, Inc. •. • ••• • Soprema, Inc"..: Soprema, Inc. Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. Soprema, Inc. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 15 of 160 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Manufacturer Application Number 1. Generic 2. Soprema, Inc. 3. Karnak Corporation 4. Soprema, Inc. 5. Thermo Manufacturing Systems, LLC 6. Quest Construction Products LLC dba United Coatings 7. Insulating Coatings Corporation 8. Henry Company 9. National Coating Corp. 10. Soprema, Inc. 11. Generic MIAMI.DADE COUNTY APPROVED Flood coat and gravel/slag with an application rate of 60 lbs./sq. & 400 lbs./sq., respectively. Gravel applied at 400 lbs./sq., adhered with COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 4 gal./sq. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal./sq. Cural Aluminizer applied at an application rate of 2 gal./sq. Super Prep Elastomeric Roof Maintenance Coating appy in two coats at an application rate of 1.5 gal./sq./coat. •.... • • . . United Coatings Roof Mate Coating, appligil jp�one bzt;.cb4 at a rate of 1.5 gal./sq., and one finish co4,44 tjte of 1.5. gal./sq. .... .... • . •Astec 2000 Finish Coat applied in two bang jp t s at a rate j 0.75 gal./sq./coat and two finish coats at %rdteO 0.75•.:.. • gal./sq./coat. . • • HE280DC White Elastomeric Roof Coatipg applied itttuvo • • coats at an application rate of 1 gal./sq./044. : ... . • Acryshield® A500 applied in two coats at an application rate' of 1 gal./sq./coat. R Nova Plus applied in two coats. Base coat is applied at 3 gal/sq. (1.2 L/m2) and allowed to dry. A top coat is applied at 1 gal/sq. (0.4 L/m2). Semi -ceramic coated colored granules. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 16 of 160 EVIDENCE SUBMITTED: Test A2encv/Identifer Report Name Date Florida Testing Engineering TAS 114-D GL0904-02 05/01/09 & Consulting Inc. TAS 114-D GL0409-03 05/01/09 Factory Mutual Research Corp. 1W8A1.AM FM 4470 07/15/93 1Z3A6.AM FM 4470 04/27/95 3000507 FM 4450 02/16/00 3009610 FM 4450 10/22/01 3008869 FM 4470 03/19/01 3002351 FM 4470 02/28/03 3017614 FM 4470 02/27/06 3025860 FM 4470 04/17/06 3029098 FM 4470 10/25/07 3032109 FM 4470 07/21/08 3026128 FM 4470 08/04/06 3024311 FM 4470 11/01/06 3036182 FM 4470 07/3069 • • 3014751 FM 4470 : .• • 08/27703' . 3023458 FM 4470 . 07/1$%0: •• 3023749 FM 4470 09/28/0( •• 3031818 FM 4470 .... 02/2049 • 3X3A7.AM FM 4470 •••••• 09/013194.• 3045101 FM 4470• • 11/05/12 • • 3037437 FM 4470 • • • • 11/09769 • • 3008441 FM 4470 . . . 10/17/00• •• 3044630 FM 447002/14!}2: •• • 3042559 FM4470 •.�• 10/loll • : • • . 3047439 FM 4470 07/22/13.: 3045734 FM 4470 04/04/12 3046765 FM 4470 02/15/13 3047351 FM 4470 10/09/14 3051408 FM 4470 08/13/14 3054633 FM 4470 12/18/15 RR203650 FM 4470 12/18/15 3044801 FM 4470 02/27/12 3053841 FM 4470 03/27/15 3051109 FM 4470 05/11/15 3053475 FM 4470 02/11/16 RR203157 FM 4470 11/06/15 RR201595 FM 4470 06/17/15 RR203472 FM 4470 02/05/16 Underwriters Laboratories R11436 UL 790 06/18/13 Dynatech Engineering Corp. 10.94.27 TAS 114 10/27/94 2491-04.95 TAS 114 01/04/95 MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 17 of 160 EVIDENCE SUBMITTED: (CONTINUED) Test Agency/Identifier Exterior Research & Design, LLC Trinity I ERD MIAMI•DADE COUNTY APPROVED Report 2003.02.97-1 2003-2.04.97-1 2002.07.97-1 2755.09.02 2760.01.05-3 2761.09.03 2761.10.03-2 2777.09.05-R2 2774.04.05-R1 S12370.03.09-1 S12370.03.09-2 S12370.03.09-3 C8500SC.11.07-R1 S11440.06.10 S32840.06.10 -R1 S11440.01.11 -R1 S11440.11.10-4 S11440.12.10 -1-R1 S43210.11.14 S45520.11.13 -R2 S39500.12.12 -R1 S39320.01.12 -R1 S47170.11.14 S32700.12.10 -R2 S35860.12.11 -1-R1 S35860.12.11-2 S35860.05.12 -1-R2 S35860.05.12 -2-R3 S35860.05.12-3 S35860.09.12 -R2 S 14000.08.09-R2 S39970.07.12-2 S39970.07.12 -R1 S39970.07.12 -1B -R1 S47160.01.14 -R1 S45010.02.14 S43400.08.14-5 S43400.08.14-6 S43400.08.14 -7-R1 S43400.09.14-9 S43400.09.14-10 S45010.02.14 S43400.08.14 -4-R1 S44110.09.14-3 Name TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 Date 02/15/97 04/15/97 08/15/97 10/19/02 02/22/05 09/02/03 10/03/03 05/24/02 TAS 114 04/18/07 ASTM D6164 03/06/09 ASTM D6164 03/06/09 ASTM D6162 03/06/09 TAS 117(B) ASTM D6862 08/07/09 ASTM D4798 TAS 110 06/QWi9•. TAS 117 (B) : .•. 12/lr/14' ASTM D6164 •06/V/1r: ASTM D2178 11/17/19 • ASTM D6163 • ... 06/07,/12, ASTM D1876 •....• 11/190/414.• Physical Properties . 03/26/14• Physical Properties' • • • 12/2T/1!• FM 4474 & TAS 1121 . . 05/24/12 FM 4474 & TAS 114 ' 11/E0/44: • ASTM D6162 07/C/14 . ASTM D2178 12/12/14.: ASTM D4601 12/12/11 ASTM D6163 02/14/13 ASTM D6164 08/28/14 ASTM D6164 05/08/12 ASTM D6163 12/12/14 TAS 114 10/09/09 ASTM D6164 07/12/12 ASTM D6162 12/12/14 ASTM D6162 12/12/14 FM 4470 & TAS 114 (H) 12/11/14 ASTM D6506 02/07/14 ASTM D6163 08/26/14 ASTM D6164 08/26/14 ASTM D6164 11/20/14 ASTM D6164 09/02/14 ASTM D6298 09/08/14 ASTM D6506 02/07/14 ASTM D6163 10/24/14 ASTM D6163 09/08/14 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 18 of 160 EVIDENCE SUBMITTED: (CONTINUED) Test Agency/Identifier Trinity I ERD PRI Construction Materials Technologies, LLC MIAMIDADE COUNTY APPROVED Report S44110.09.14 -7C S44220.09.14-1 S44220.09.14 -7A S11440.11.10 -3-R2 539500.02.12 SOP -049-02-01 SOP -043-02-01 SOP -042-02-01 SOP -041-02-01 SOP -040-02-01 SOP -010-02-01.03 SOP -050-02-01 SOP -056-02-01 Name ASTM D6164 ASTM D6162 ASTM D4601 ASTM D4601/TAS 117(B) Physical Properties ASTM D1644 / D2196 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 TAS -138 ASTM D3019 Various . . . . . .. . Date 09/02/14 09/08/14 09/08/14 08/26/14 02/23/12 05/31/12 02/27/12 02/27/12 02/27/12 02/27/12 07/26/11 07/12/12 09/12/12 . • .. • ... • .. .. • • • •••• • • •••• .... • .. • • .. .. •••• • . • • • • .. • ••• . NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 19 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(34): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, Sopra-ISO r, M -Shield, H -Shield Minimum 1.4" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard minimum 1/8" thick N/A N/A • . ...• • Note: All insulation shall be adhered to the deck with OlyBond Adhesive FasteneVat ?. • • • •• •• gallon/square. Please refer to Roofing Application Standard RAS 117 for insulaiiaaftachment. • Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied a,t.acate of 1 .... (Optional) gal./sq., to top surface of any insulation, base or ply sheet phos to applic icor. • of next layer. : ....• • Base Sheet: One layer of Sopra G, Modified Sopra G, Sopra IV, Sopra yj,.$4prabase,• • (Optional) Soprabase S, Elastophene Sanded, Colphene Sanded, Elastophene:Sandad . 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene IIS 6si . Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Santl1d, Colpheite • : • • 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 ' • PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied ply membrane. Ply Sheet: One or two layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, 4ovralcne Flam 250*, Sopralene 250 SP, torch -applied. • • • • • • • Or MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 85 of 160 Ply Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene (Continued) Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to three plies of Sopra IV or Sopra VI ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied cap membrane. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, So ralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antiroc c, tore -app ied. • • • •••• Surfacing: Maximum Design Pressure: MIAMI DADE COUNTY APPROVED • • • • Or ••• •••• • • • • • ••• • Elastophene GR, Elastophene FR GR, Elastophene LS FR GIL.Lastophene • FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 1•SA FR GR,• • •. Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopraletit�250 FR OR,• • • Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 25nillta FR OR, • • • Sopralast 50 TV Alu Sanded adhered in a full mopping of apDr.o a.d asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. yr in cOLPIiY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons/ sgiyare. to VW • • • • • • • • surfaced ply membrane. ' • •' • • • • • • • ' Surfacing is Optional on granular surfaced field cap membranes. •• Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. - 255 psf. (using ENRGY 3, H -Shield, Sopra-ISO r , M -Shield) (See General Limitation #9.) - 270 psf. (using ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s) (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 86 of 160 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed celi•foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be tpplied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip moped 8"JibUds in three rows, one at each side lap and one down the center of the sheet allowing ai i intinuous area of . ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed eveia j;' in eac1 ippon to allow cross ventilation. Asphalt application of either system shall be at a minimum rats af'12 lbs'/s4...' • . • . • Note: Spot attached systems shall be limited to a maximum design pressure of 44,6:p1. .. '• 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Foie ow) value ofeLalri lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastVe4d$lue, as field- •, tested, are below 275 lbf. insulation attachment shall not be acceptable. '• • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attackent �s bas ;d �n a. • • minimum fastener resistance value in conjunction with the maximum design value listed within a speer system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 160 of 160 STATE OF FL* ,IDA st DEPARTMENT IF f USINESS AND PROFESSItta NAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 , 2601 BLAIR STONE ROAD TALLAHASSEE FL 32399-0783 PRITTS, MICHAEL SCOTT SR PRITTS, INC PO BOX 5187 FORT LAUDERDALE FL 33310 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CGC1524058 ISSUED: 07/05/2016 CERTIFIED GENERAL CONTRACTOR PRITTS, MICHAEL SCOTT SR PRITTS, INC IS CERTIFIED under the provisions of Ch_489 FS. Expiration date : AUG 31, 2018 L1607050001635 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD LICENSE NUMBER CGC1 524058 The GENERAL CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 PRITTS, MICHAEL SCOTT SR PRITTS, INC 2000 NW 22ND STREET FORT LAUDERDALE FL 33311 ISSUED: 07/05/2016 DISPLAY AS REQUIRED BY LAW SEQ # L1607050001635 l;. f 11. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2016 THROUGH SEPTEMBER 30, 2017 DBA: Business Name: PRITTS INC • Owner Name: MICHAEL S PRITTS SR i , Business Location: 2000 NW 22 ST FT LAUDERDALE Business Phone: 954-733-7663 Rooms Seats Employees 10 Receipt#:GENERA157 L7CONTRACTOR (CERTIFIED Business Type:GENERAL CONTRACTOR) Business Opened:05/19/2016 State/County/Cert/Reg:CGC152 4 0 5 8 Exemption Code: Machines Professionals For Vending Business Only of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT WHEN VALIDATED Mailing Address: PRITTS INC PO BOX 5187 FORT LAUDERDALE, FL 33310 This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. 2016 - 2017 Receipt #05C-15-00005865 Paid 08/30/2016 27.00 ACORO CERTIFICATE OF LIABILITY INSURANCE /. DATE(MMIDD/YYYY) 1/31/2017 THIS CERT(FICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Frank H. Furman, Inc. 1314 East Atlantic Blvd. P. 0. Box 1927 Pompano Beach FL 33061 CONTACT Melissa Rhinehardt lac Nro.Exu: (954) 943-5050 (A/C. FAX (954)942-6310 E-MAIL ADDRESS: mel@furmaninsurance.com INSURER(S) AFFORDING COVERAGE NAIC 6 INSURER A:Gemini Insurance Company 10833 INSURED Pritts Inc P 0 Box 5187 Ft Lauderdale FL 33310 INSURER B:Evanston Insurance Company 35378 INSURER C : INSURER D : $ 1,000,000 INSURER E : INSURER F : CLAIMS -MADE CERTIFICATE NUMBER:Jan 2017 • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL qn SUBR WVD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MMIDD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 A CLAIMS -MADE X OCCUR DAMAGE • NTD PREMI $ 50,000 VIGP018060 2/4/2017 2/4/2018 a occ rrenc= MED EXP (Any one person) $ excluded PERSONAL & ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 POLICY X ECT LOC PRODUCTS- COMP/OP AGG $ 2,000,000 OTHER: Per Project Aggregate Cap S 5,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ ANY AUTO BODILY INJURY (Per person) $ ALL OWNED AUTOS SCHEDULED AUTOS accident Per BODILY INJURY ( ) $ HIRED AUTOS _ NON -OWNED AUTOS PROPERTY DAMAGE Per accident $ S UMBRELLA LIAB OCCUR EACH OCCURRENCE $ 1 000 000 B x EXCESS LIAB CLAIMS -MADE AGGREGATE $ 1 000 000 X DED RETENTION$ 0 t4KLV2EUL100987 2/4/2017 2/4/2018 $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY PER STATUTE OTH- ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? Y I N N 1 A E.L. EACH ACCIDENT S (Mandatory in NH) If describe E.L. DISEASE - EA EMPLOYE: $ yes, under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS 1 LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached i1 more space is required) •CCC1328313 & CGC1524058 CERTIFICATE HOLDER CANCELLATION Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, FL 33138 ACORD 25 (2014/01) NS025 r7mann SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Dirk DeJong/MR ©1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD CERTIFICATE OF LIABILITY INSURANCE Date 1 4/26/2017 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691 This Certificate is issued as a matter of information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. (727) 938-5562 Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer B: Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions. and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL LIABILITY Commercial General Liability Claims Made Occur 13 Each Occurrence $ Damage to rented premises (EA occurrence) $ Med Exp $ Personal Adv Injury 5 General aggregate limit applies per: DPolicy ❑ Project ❑ LOC General Aggregate $ Products - Comp/Op Agg $ AUTOMOBILE ...... MOM LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non -Owned Autos Combined Single Limit (EA Accident) $ Bodily Injury (Per Person) $ Bodily Injury (Per Accident) $ Property Damage (Per Accident) 5 EXCESS/UMBRELLA LIABILITY IOccur ❑ Claims Made Deductible Each Occurrence Aggregate A Workers Compensation and Employers' Liability Any proprietor/partner/executive officer/member excluded? NO If Yes, describe under special provisions below. WC 71949 01/01/2017 01/01/2018 x I wC Statu- I tory Limits 1OTH- ER E.L. Each Accident 51,000,000 E.L. Disease - Ea Employee 51,000,000 E.L. Disease - Policy Limits 51,000,000 Other Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616 Descriptions of OperationslLocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 91-67-600 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": Pritts, Inc. Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 01-06-14 (TD) REISSUE 04-26-17 (RK) CCC1328313 / CGC1524058 Begin Date 12/25/2013 CERTIFICATE HOLDER CANCELLATION VILLAGE OF MIAMI SHORES BUILDING DEPARTMENT 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives. _,alte. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2016 THROUGH SEPTEMBER 30, 2017 ReCelpt :ROOF NG/OSHEET Business Type: (ROOFING) DBA: Business Name: FRITTS INC Owner Name: MICHEAL SCOTT PRITT Business Location: 2000 NW 22 ST FT LAUDERDALE Business Phone: 954-733-7663 Rooms Seats Employees 1 Business Opened:O1/09/2013 State/County/Cert/Reg :CCC1328313 Exemption Code: Machines METAL CONTRACTOR Professionals For Vending Business Only • Vending Type: Tax Amount 11uI,uuc, VI ..c...".. Transfer Fee ..a. NSF Fee Penalty — - Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT WHEN VALIDATED Mailing Address: DANA F PRITTS (OWNER) PO BOX 5187 FORT LAUDERDALE, FL 33310 This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. 2016 - 2017 Receipt #05C-15-00005865 Paid 08/30/2016 27.00 syr, Jemuc%Jr rLumuuR F DEPARTMENT OF BUSINESS AND P.-:OFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 2601 BLAIR STONE ROAD , TALLAHASSEE FL 32399-0783 PRITTS, MICHAEL SCOTT SR PRITTS INC PO BOX 5187 FORT LAUDERDALE FL 33310 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CCC1328313 • ;.FSSUED: 08/03/2016 CERTIFIED ROOFING CONTRACTOR PRITTS, MICHAE4SCOTT SR`"-:. PRITTS INC IS CERTIFIED under the provisions of Ch.489 FS. Expiration date : AUG 31, 2018 L1608030001550 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD LICENSE NUMBER CCC 1328313 The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 PRITTS, MICHAEL SCOTT PRITTS INC PO BOX 5187 •-r- .R: FORT LAUDERDALE -.. FL 33310 •r .. A:.,, , .' ISSUED: 08/03/2016 , 4 4 a A ♦ ,t i • DISPLAY AS REQUIRED BY LAW SEQ # L1608030001550