Loading...
REV-17-467cecti 4t1) Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING E] PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS Master Permit No. c U;IVED FE 2 3 2017 54) FBC 201 �C 13-3t,toz. Sub Permit No. 2 e.Ai 11 4 6-7 E4 REVISION ❑ EXTENSION ❑ RENEWAL D CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: .32s- 4' avchttLel: D2 City: Miami Shores County: Miami Dade Zip: a?/3a Folio/Parcel#: /1 320,5 =- O2 -7—O,53 9 Is the Building Historically Designated: Yes NO JC Occupancy Type: Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): Ci2x.e442 ed 144 Address:div!,�,�,�/3Z.� /Ss. 8,,g7/.S/OOLC; ,%a.0 _ City: 4711, State: CL- FFE: Phone#: Zip:/3- Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Address: City: State: Zip: -mkt p(ion-e( Phone#: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ r 6' £ aa- Square/Linear Footage of Work: 2/6 Z- 2.. ❑ Repair/Replace n Demolition Type of Work: ❑ Addition ❑ Alteration Description of Work: 'c ROV oc' 7-6-71., 06- ❑ New ti A Ten_ - c-••4 L t ?-7A-) / 7)9 L✓ r // teA/C 4/a44 !.v ./•l Da-- S fig- L . A• it./ At c -7 - Specify color of color thru tile: Submittal Fee $ Permit Fee $ �S •601 cb+ 014 ;o OW • aiidu9 vstoSB+ Scanning Fee $ 3 • \ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ ) •6) (Revised02/24/2014) etas , t E QuA f•}tri .mmo3 rte j < CCF $ k 0.14 'veldttt 5 DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ ��•I � it d s-' W Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature • OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 1hl day of 6 " - , 20 /7 , by day of , 20 , by Ay%/G• , who is penally known to , who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PU Sign: Print: Seal: fad ********* APPROVED BY (Revised02/24/2014) JOSE J. 13IRAL0O Notary Public - State of FIoda Commission I FF 228273 MY Comm. Eaglets Aug 31, 2019 Aienvest NetwpAus /40 NOTARY PUBLIC: Sign: Print: Seal: **************************************************************** ` Plans Examiner Zoning Structural Review Clerk 11.40 SECTION 07 55 52 MODIFIED BITUMINOUS PROTECTED MEMBRANE WATERPROOFING PART1 GENERAL 1.01 SUMMARY A. Work shall include, but is not limited to, the followin 1. Preparation of existing deck, and all flashing s 2. SBS -modified bitumen base ply(s) heat -welded. 3. SBS -modified bitumen cap sheet heat -welded. 4. Liquid -applied, reinforced flashings. 5. All related materials and labor required to c waterproofing necessary to receive specified manufactu 1.02 DEFINITIONS A. ASTM D 1079 -Definitions of Term Relating to Roofing and Waterproofing. B. The National Roofing Contractors Association (NRC) .Roofing.. Waterproofing Manual, Fifth Edition Glossary. 1.03 REFERENCES • . . .. • ..• • • . • • •• •' • • • .•.. .. . • • • • • •••• • •• •• A. AMERICAN SOCIETY OF CIVIL ENGINEERS - Reference Doeament ASCE 7, Minimum Design Loads for Buildings and Other Structures. • • • • .. B. AMERICAN STANDARD OF TESTING METHODS (ASTM): • • 1. ASTM C 836 - Standard Specification for High Sdids .Conter:t' •C;t td Liquid -Applied Elastomeric Waterproofing Membrana . far Use • with Separate Wearing Course. • • 2. ASTM C 920 - Standard Specification for Elastomeric Joint Sealants 3. ASTM D 41 - Standard Specification for Asphalt Primer Used in Roofing, Damp proofing, and Waterproofing. 4. ASTM D 3019 - Standard Specification for Lap Cement Used with Asphalt Roll Roofing, Non-Fibered, Asbestos-Fibered, and Non-Asbestos- Fibered. 5. ASTM D 3746 - Standard Test Method for Impact Resistance of Bituminous Roofing System. 6. ASTM D 4586 - Standard Specification for Asphalt Roof Cement, Asbestos -Free. 7. ASTM D 4601 - Standard Specification for Asphalt -Coated Glass Fiber Base Sheet Used in Roofing. Omar Cassola Residence 07 55 52-1 MOD. BITUMEN WATERPROOFING • • • • • • 8. ASTM D 5147 - Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material. 9. ASTM D 5385 - Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes. 10. ASTM D 5849 - Standard Test Method for Evaluating Resistance of Modified Bituminous Roofing Membrane to Cyclic Fatigue (Joint Displacement) 11. ASTM D 6162 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements. 12. ASTM D 6163 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements. 13. ASTM D 6164 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements. 14. ASTM D 7379 - Standard Test Methods for Strength of Modified Bitumen Sheet Material Laps Using Cold Process Adhesive. 15. ASTM E 108 - Standard Test Methods for Fire Tests of Roof Coverings. C. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI): 1. ANSI/SPRI/FM 4435/ES-1 Wind Design Standard for Edge System Used System. moi. •••• • • with Low ..,, Roofing, .,sa,.... •• • •• • •• • •• • • • • • •. • ANSI/SPRI FX -1, Standard Field Test Procedure for Determining the • • • Withdrawal Resistance of Roofing Fasteners. •• • • • • • • •08% ANSI/SPRI IA -1, Standard Field Test Procedure for Determining the • •. . Mechanical Uplift Resistance of Insulation Adhesives over Various • • • • •• • Substrates. • • • •.4. • ANSI/FM 4474- American National Standard for Evaluating the Simulated •• • • • • • • Wind Resistance of Roof Assemblies Using Static Positive and/or ▪ •• Negative Differential Pressures. • • • D. FACTORY MUTUAL (FM): 1. FM 4450 - Approval Standard - Class I Insulated Steel Roof Decks. 2. FM 4470 - Approval Standard - Class 1 Roof Covers. E. FLORIDA BUILDING CODE (FBC): 1. 2014 Florida Building Code (FBC). F. INTERNATIONAL CODES COUNCIL (ICC): 1. 2012 International Building Code (IBC). G. NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA). 1. UL 790 Standard Test Methods for Fire Tests of Roof Coverings. 2. UL 1256 — Fire Test of Roof Deck Constructions. •• 1.04 ACTION SUBMITTALS Omar Cassola Residence 07 55 52-2 MOD. BITUMEN WATERPROOFING A. Product Data Sheets: Submit manufacturer's product data sheets, installation instructions and/or general requirements for each component. B. Safety Data Sheets: Submit manufacturer's Safety Data Sheets (SDS) for each component. C. Sample warranty from the manufacturer and contractor. D. Provide roof plan and representative detail shop drawings. E. Current Notice of Acceptance (NOA) 1.05 INFORMATIONAL SUBMITTALS A. Submit a letter from the waterproofing manufacturer indicating the contractor is an authorized applicator. 1.06 CLOSEOUT SUBMITTALS A. Warranty: Provide manufacturer's and contractor's warranties upon project completion. 1.07 ' QUALITY ASSURANCE A. MANUFACTURER QUALIFICATIONS: 1. Manufacturer shall have 20 years of manufacturing exhr.ienee. ....... • 2. Manufacturer shall have trained technical service..rapresebtatives . employed by the manufacturer, independent of sales. • 3. Manufacturer shall provide site visit reports in a timely etafiner. .'. '. •.•. . .. B. CONTRACTOR QUALIFICATIONS: 1. Contractor shall be authorized by the manufacturer.td.igtall sT edf dd materials prior to the bidding period through latiftvtory project • completion. ' 2. Applicators shall have completed projects of similar sCppe•�psing §apse pr similar materials specified. ' • • 3. Contractor shall provide full time, on-site superintendent or foreman experienced , with the specified waterproofing from beginning through satisfactory project completion. 4. Applicators shall be skilled in the application methods for all materials. 5. Contractor shall maintain a daily record, on-site, documenting material installation and related project conditions. 6. Contractor shall maintain a copy of all submittal documents, on-site, available at all times for reference. 1.08 DELIVERY, STORAGE AND HANDLING A. Refer to each product data sheet or other published literature for specific requirements. Omar Cassola Residence 07 55 52-3 MOD. BITUMEN WATERPROOFING • • • B. Deliver materials and store them in their unopened, original packaging, bearing the manufacturer's name, related standards, and any other specification or reference accepted as standard. C. Protect and store materials in a dry, well -vented, and weatherproof location. Only materials to be used the same day shall be removed from this location. During cold weather, store materials in a heated location, removed only as needed for immediate use. D. When materials are to be stored outdoors, store away from standing water, stacked on raised pallets or dunnage, at least 4 in or more above ground level. Carefully cover storage with "breathable" tarpaulins to protect materials from precipitation and to prevent exposure to condensation. E. Carefully store waterproofing membrane materials delivered in rolls on -end with selvage edges up. Store and protect roll storage to prevent damage. F. Properly dispose of all product wrappers, pallets, cardboard tubes, scrap, waste, and debris. All damaged materials shall be removed from job site and replaced with new, suitable materials. 1.09 SITE CONDITIONS A. SAFETY: •••••• 1. The contractor shall be responsible for complying with all project -related ""• • • safety and environmental requirements. •• • •• • • • • • •�.• Heat -welding shall include heating the specified membrane ply using• • • • propane roof torches or electric hot-air welding equipment. The • •• ••• •• • contractor shall determine when and where conditions are appropriate to • •" •' •••• utilize heat -welding equipment. When conditions are determined by the •• • •• • • • •• • •• contractor to be unsafe to proceed, equivalent SBS -modified bitumen • • • materials and methods shall be utilized to accommodate requirements • • • and conditions. ▪ •• •3.� • Refer to NRCA CERTA recommendations, local codes and building owner's requirements for hot work operations. 4. The contractor shall review project conditions and determine when and where conditions are appropriate to utilize the specified liquid -applied, or semi-solid waterproofing materials. When conditions are determined by the contractor to be unsafe or undesirable to proceed, measures shall be taken to prevent or eliminate the unsafe or undesirable exposures and conditions, or equivalent approved materials and methods shall be utilized to accommodate requirements and conditions. 5. The contractor shall refer to product Safety Data Sheets (SDS) for health, safety, and environment related hazards, and take all necessary measures and precautions to comply with exposure requirements. B. ENVIRONMENTAL CONDITIONS: 1. Monitor substrate temperature and material temperature, as well as all environmental conditions such as ambient temperature, moisture, sun, Omar Cassola Residence 07 55 52-4 MOD. BITUMEN WATERPROOFING cloud cover, wind, humidity, and shade. Ensure conditions are satisfactory to begin work and ensure conditions remain satisfactory during the installation of specified materials. Materials and methods shall be adjusted as necessary to accommodate varying project conditions. Materials shall not be installed when conditions are unacceptable to achieve the specified results. 2. Precipitation and dew point: Monitor weather -to ensure the project environment is dry before, and will remain dry, during the application of waterproofing materials. Ensure all waterproofing materials and substrates remain above the dew point temperature as required to prevent condensation and maintain dry conditions. 3. Cold adhesive application: Primer, where used, shall be fully dry before proceeding. During cold weather, store the specified membrane adhesives, flashing cements and mastics in heated storage areas. Take all necessary measures and monitor application conditions, to ensure the adhesive and cement materials are no Tess than 70°F (21°C) at the point of contact with the membrane. 4. Self-adhesive membrane application: During cold weather, store the specified self-adhesive membrane and primer materials in heated storage areas to ensure materials remain no less than 70°F (21°C) during application. Ensure conditions allow primer to remain tacky, but root et so that primer will not transfer to finger when toucl?ed.' • Self-aclbe4ive primer shall not fully dry and lose tack before applying1he•self-adhee4 membrane. Ensure conditions remain satisfactory to WHIM membfane .• •••• •• • • • adhesion as specified. • • ••• •• •• • 5. Heat -Welding Application: Take all necessary precautioasand measures • • to monitor conditions to ensure all environmental conditivis are•sa{eio proceed with the use of torches and hot-air MI? riI equipnient. • • Combustibles, flammable liquids and solvent vapors thgt represent •a• • hazard shall be eliminated. Flammable primers and cleaners shall.be fully • dry before proceeding with heat -welding operations. Prevent or protttt wood, paper, plastics and other such combustible materials from direct exposure to open flames from roof torches. Refer to NRCA CERTA recommendations. 1.10 PERFORMANCE REQUIREMENTS A. WIND UPLIFT RESISTANCE: 1. Performance testing shall be in accordance with ANSI/FM 4474, FM 4450, FM 4470, UL 580 or UL 1897. a. Waterproofing Membrane Design Pressures: Calculated in accordance with ASCE 7, or applicable standard, for the specified waterproofing membrane attachment requirements: Omar Cassola Residence 07 55 52-5 MOD. BITUMEN WATERPROOFING Field (Zone 1, Main Roof): - 56.0 psf. ii. Perimeter (Zone 2, Main Roof): - 94.0 psf. iii. Corners (Zone 3, Main Roof): - 94.0 psf. iv. Field (Zone 1, Elevator Roof) N/A v. Perimeter (Zone 2, Elevator Roof) - 97.0 psf. vi. Corners (Zone 3, Elevator Roof) -113.0 psf. B. FIRE CLASSIFICATION: 1. Performance testing shall be in accordance with UL 790, ASTM E108, FM 4450 or FM 4470. a. Meets requirements of UL Class A or FM Class A. 2. Performance testing shall be in accordance with UL 1256, FM 4450 or FM 4470 to meet the specified requirements for interior flame spread and fuel contribution. a. Meets requirements of UL 1256, or FM Class 1. C. IMPACT RESISTANCE: 1. Performance testing for impact resistance shall be in accordance with FM 4450, FM 4470, ASTM D3746 or CGSB 37 -GP 56M to meet the specified impact resistance requirements. a. Meets requirements for FM -SH (Severe Hail), ASTM D3746, or CGSB 37 -GP 56M. ... • • 1'ii' WARRANTY • • •• • •• •• •• .• •• • • • •• • A. • • :Manufacturer's No Dollar Limit (NDL) Warranty. The manufacturer shall provide • •tflt.owner with the manufacturer's warranty providing labor and materials for 20 •• • • years from the date the warranty is issued. • B. •..Tbe contractor shall guarantee the workmanship and shall provide the owner with • • • the: contractor's warranty covering workmanship for a period of 2 years from ••• corffipletion date. •• • • • • ▪ • .•. • .. PART 2 PRODUCTS 2.01 MANUFACTURER A. SINGLE SOURCE MANUFACTURER: All SBS modified bitumen membrane and flashing sheets shall be manufactured by a single supplier with 20 years or more manufacturing history in the US. 1. Comply with the Manufacturer's requirements as necessary to provide the specified warranty. B. ACCEPTABLE MANUFACTURER: Omar Cassola Residence 07 55 52-6 MOD. BITUMEN WATERPROOFING 1. SOPREMA, located at: 310 Quadra) Dr.; Wadsworth, OH 44281; Tel: 800-356-3521; Tel: 330-334-0066; Website: www.soprema.us. 2.02 WATERPROOFING MEMBRANE A. WATERPROOFING MEMBRANE BASIS OF DESIGN: SOPREMA 2.03 SBS -MODIFIED BITUMEN MEMBRANES A. BASE PLY: 1. BASE PLY, HEAT -WELDED: a. SOPREMA COLPHENE FLAM 180: SBS -modified bitumen membrane with plastic burn -off film on top and bottom surfaces. Non -woven polyester reinforcement. Meets or exceeds ASTM D6164, Type I, Grade S per ASTM D5147 test methods. i. Thickness: 114 mils (2.9 mm) ii. Width: 39.4 in (1 m) iii. Length: 32.8 ft (10 m) iv. Roll weight: 73 Ib (36.2 kg) v. Net mass per unit area, Ib/100 sq ft (g/sq m): a) 80 Ib (3596 g) •••• • • vi. Peak load @ 0°F (-18°C), Ibf/in (kN/m). •• • • •; •; • •; a) MD 115 Ibf/in (20.1 kN/m), XMQ:90 Ibf/ib j15.'8 kN/m) • vii. Elongation at peak Toad @ 0°F (-18°C), 4 O h (kN/mr • • • a) MD 35%, XMD 40% • . viii. Peak load @ 73.4°F (23°C), Ibf/in (kN/nr)? • • • • • .. .. a) MD 85 Ibf/in (14.9 kN/m), XMD ? (11.4 kN/m) ix. Elongation' at peak load @ 73.4°F (23°Q), Ibfjin (kNri� • • • . • a) MD 55%, XMD 60% • .• • .• . . . .. . ... . .. x. Ultimate Elongation @ 73.4°F (23°C), Ibf/in (kN/m): ' • a) MD 65%, XMD 80% xi. Tear Strength @ 73.4°F (23°C), Ibf (N): a) MD 125 Ibf (556 N), XMD 85 Ibf (378 N) xii. Low temperature flexibility, °F (°C): a) MD/XMD: -15°F (-26°C) xiii. Dimensional stability, %: a) MD/XMD: Less than 0.5% xiv. Compound stability, °F (°C): a) MD/XMD: 240°F (116°C) xv. ASTM D 5385: a) Pass Omar Cassola Residence 07 55 52-7 MOD. BITUMEN WATERPROOFING B. FLASHING BASE PLY 1. FLASHING BASE PLY, HEAT -WELDED: a. SOPREMA COLPHENE FLAM 180: SBS -modified bitumen membrane with plastic burn -off film on top and bottom surfaces. Non -woven polyester reinforcement. Meets or exceeds ASTM D6164, Type I, Grade S per ASTM D5147 test methods. i. Thickness: 114 mils (2.9 mm) ii. Width: 39.4 in (1 m) iii. Length: 32.8 ft (10 m) iv. Roll weight: 73 Ib (36.2 kg) v. Net mass per unit area, Ib/100 sq ft (g/sq m): a) 80 Ib (3596 g) vi. Peak load @ 0°F (-18°C), Ibf/in (kN/m). a) MD 115 Ibf/in (20.1 kN/m), XMD 90 Ibf/in (15.8 kN/m) vii. Elongation at peak load @ 0°F (-18°C), Ibf/in (kN/m): a) MD 35%, XMD 40% viii. Peak load @ 73.4°F (23°C), Ibf/in (kN/m): ." a) MD 85 Ibf/in (14.9 kN/m), XMD 65 Ibf/in (11.4 kN/m) .... • •• „ • • • •• ix. Elongation at peak load @ 73.4°F (23°C), Ibf/in (kN/m): •• • • a) MD 55%, XMD 60% ••x. Ultimate Elongation @ 73.4°F (23°C), Ibf/in (kN/m): • • • •• •••• •„• • •,,,,• a) MD 65%, XMD 80% •• • xi. Tear Strength @ 73.4°F (23°C), Ibf (N): • •• ' • •' • • •' • • „) MD 125 IF,i /556 NI), XMD 85 II- '] I74 NI) •• • • •• •• xii. Low temperature flexibility, °F (°C): . . . •• • • . a) MD/XMD: -15°F (-26°C) • •• , • • • • • xiii. Dimensional stability, %: • • a) MD/XMD: Less than 0.5% xiv. Compound stability, °F (°C): a) MD/XMD: 240°F (116°C) xv. ASTM D 5385: a) Pass C. CAP SHEET: Omar Cassola Residence 07 55 52-8 MOD. BITUMEN WATERPROOFING 1. CAP SHEET, HEAT -WELDED: a. SOPREMA COLPHENE FLAM 180 FR GR: SBS -modified bitumen membrane Cap Sheet with a burn -off film bottom surface and mineral granule top surface. Non -woven polyester reinforced. Meets or exceeds ASTM D6164, Type I, Grade G per ASTM D5147 test methods. i. Thickness: 157 mils (4.0 mm) ii. Width: 39.4 in (1 m) Length: 32.8 ft (10 m) iv. Roll weight: 118 Ib (53.5 kg) v. Net mass per unit area, Ib/100 sq ft (g/sq m): a) 110 Ib (5350 g) vi. Peak load @ 0°F (-18°C), Ibf/in (kN/m). a) MD 115 Ibf/in (20.1 kN/m), XMD 90 Ibf/in (15.8 kN/m) vii. Elongation at peak load @ 0°F (-18°C), Ibf/in (kN/m): a) MD 35%, XMD 40% viii. Peak load @ 73.4°F (23°C), Ibf/in (kN/m): a) MD 85 Ibf/in (14.9 kN/m), XMD 65 Ibf/in (11.4 kN/m) ix. Elongation at peak load @ 73.4°F (23°C), Ibf/in (kN/m): .... a) MD 55%, XMD 60%• •••,•••• x. Ultimate Elongation @ 73.4°F (23°C), IbNi (kAUm):..• •• • .' a) MD 65%, XMD 80% • xi. Tear Strength @ 73.4°F (23°C), Ibf (N): • • • • a) MD 125 Ibf (556 N), XMD 85 Ibf 037811) xii. Low temperature flexibility, °F (°C): • • a) MD/XMD: -15°F (-26°C) ••• •• xiii. Dimensional stability, %: •••• • a) MD/XMD: Less than 0.5% ••' •• • xiv. Compound stability, °F (°C): a) MD/XMD: 240°F (116°C) xv. ASTM D 5385: a) Pass xvi. Granule Surfacing: a) White mineral granules. D. FLASHING CAP SHEET • •• • • • • •• • • • • • • • •• • • •• • • ••• •• • • • • • • • •• • • ••• • • • • • Omar Cassola Residence 07 55 52-9 MOD. BITUMEN WATERPROOFING 1. FLASHING CAP SHEET, HEAT -WELDED: a. SOPREMA COLPHENE FLAM 180 FR GR: SBS -modified bitumen membrane Cap Sheet with a burn -off film bottom surface and mineral granule top surface. Non -woven polyester reinforced. Meets or exceeds ASTM D6164, Type I, Grade G per ASTM D5147 test methods. i. Thickness: 157 mils (4.0 mm) ii. Width: 39.4 in (1 m) iii. Length: 32.8 ft (10 m) iv. Roll weight: 118 Ib (53.5 kg) . v. Net mass per unit area, Ib/100 sq ft (g/sq m): a) 110 Ib (5350 g) vi. Peak load @ 0°F (-18°C), Ibf/in (kN/m). a) MD 115 Ibf/in (20.1 kN/m), XMD 90 Ibf/in (15.8 kN/m) vii. Elongation at peak load @ 0°F (-18°C), Ibf/in (kN/m): a) MD 35%, XMD 40% viii. Peak load @ 73.4°F (23°C), Ibf/in (kN/m): a) MD 85 Ibf/in (14.9 kN/m), XMD 65 Ibf/in (11.4 kN/m) ix. Elongation at peak load @ 73.4°F (23°C), Ibf/in (kN/m): •" a) MD 55%, XMD 60% ••••• • • •. •• •. • ' •••' x. Ultimate Elongation @ 73.4°F (23°C), Ibf/in (kN/m): • • • • • a) MD 65%, XMD 80% xi. Tear Strength @ 73.4°F (23°C), Ibf (N): • • •,•••• ••••••• a) MD 125 Ibf (556 N), XMD 85 Ibf (378 N) • xii. Low temperature flexibility, °F (°C): • • • •• • " a) MD/XMD: -15°F (-26°C) • xiii. Dimensional stability, (Yo: .• • • • a) •D/XMD: Less than 0.5% • • • •"• xiv. Compound stability, °F (°C): .• a) MD/XMD: 240°F (116°C) xv. ASTM D 5385: a) Pass xvi. Granule Surfacing: a) White mineral granules. b. SOPREMA COLPHENE 180 SP: SBS -modified bitumen membrane with a plastic burn -off film on the bottom surface and a sanded top surface. Non -woven polyester reinforcement. Meets or exceeds ASTM D6164, Type I, Grade S per ASTM D5147 test methods. i. Thickness: 87 mils (2.2 mm) ii. Width: 39.4 in (1 m) Omar Cassola Residence 07 55 52-10 MOD. BITUMEN WATERPROOFING 2.04 ACCESSORIES iii. Length: 49.2 ft (15 m) iv. Roll weight: 86 Ib (39 kg) v. Net mass per unit area, Ib/100 sq ft (g/sq m): a) 54 Ib (2625 g) vi. Peak load @ 0°F (-18°C), Ibf/in (kN/m). a) MD 110 Ibf/in (19.3 kN/m), XMD 85 Ibf/in (14.9 kN/m) vii. Elongation at peak load @ 0°F (-18°C), Ibf/in (kN/m): a) MD 35%, XMD 40% viii. Peak load @ 73.4°F (23°C), Ibf/in (kN/m): a) MD 85 Ibf/in (14.9 kN/m), XMD 65 Ibf/in (11.4 kN/m) ix. Elongation at peak load @ 73.4°F (23°C), Ibf/in (kN/m): a) MD 55%, XMD 60% x. Ultimate Elongation @ 73.4°F (23°C), Ibf/in (kN/m): a) MD 60%, XMD 65% xi. Tear Strength @ 73.4°F (23°C), Ibf (N): a) MD 125 Ibf (556 N), XMD 85 Ibf (378 N) xii. Low temperature flexibility, °F (°C): a) MD/XMD: -15°F (-26°C) xiii. Dimensional stability, %: • • • a) MD/XMD: Less than 0.5% • • • • • • .• • xiv. Compound stability, °F (°C): • • • •• •. ••. •. • •• a) MD/XMD: 240°F (116°C) • • xv. ASTM D 5385: •••• •• • • • •• • • a) Pass •••• • •• • • • • •• • • •• •• •. •. • • • • • •• • • • • • • • • • • . • •• • ••• • • • •• A. PRIMERS: 1. SOPREMA ELASTOCOL 500 Primer: Asphalt cut-back primer. Primer for the preparation of membrane substrates for heat -welded and SOPREMA COLPLY and SOPREMA COLPLY MODIFIED ADHESIVE, solvent -based, cold adhesive -applied and cement applications. a. Meets or exceeds ASTM D41 b. VOC content: 350 g/L or less. 2. SOPREMA ELASTOCOL 350 Primer: Polymer emulsion primer, meeting low VOC requirements for the preparation of membrane substrates for torch and SOPREMA COLPLY and SOPREMA COLPLY MODIFIED adhesive and flashing cement applications. B. GENERAL PURPOSE SEALANT Omar Cassola Residence 07 55 52-11 MOD. BITUMEN WATERPROOFING ••. • 1. SOPREMA SOPRAMASTIC SP1: General purpose, paintable, gun - grade, elastomeric, polyether moisture curing sealant for sealing SBS membrane terminations, Kynar 500 PVDF, horizontal and vertical construction joints. a. VOC Content: 20 g/L or less. b. Meets or exceeds ASTM C920, Type S, Grade NS, Class 50. c. Standard color. C. LIQUID -APPLIED REINFORCED FLASHING SYSTEM: 1. SOPREMA ALSAN RS 230 Flash, Catalyzed polymethyl methacrylate (PMMA) SOPREMA ALSAN RS 260 LO FLASH, Catalyzed polymethacrylate (PMA) resin with polyester reinforcing fleece fabric fully embedded into the resin to form fully -reinforced waterproofing membrane flashings. a. VOC Content: No VOC content. b. SOPREMA ALSAN RS 230 FLASH SOPREMA ALSAN RS 260 LO FLASH: Polymethyl methacrylate (PMMA) polymethacrylate (PMA) liquid resin. c. SOPREMA ALSAN RS CATALYST POWDER: Reactive agent added to the PMMA liquid resin to induce curing. d. SOPREMA ALSAN RS FLEECE: Polyester reinforcement fabric. • e. Color: Flash color and finish to match Field. • • ••'• D. .•.MIISIERAL GRANULES: • .• • • • • ••1.••• SOPREMA Granules: No. 11, mineral coated colored granules, color to • match cap sheet, supplied by membrane cap sheet manufacturer. • • •• •••• ••••••• a. SOPREMA GRANULES ••• • •••• • • •..EXECUTION • 3M.: EXAMINATION . . • • • • • A. Examination includes visual observations, qualitative analysis, and quantitative testing measures as necessary to ensure conditions remain satisfactory throughout the project. B. The contractor shall examine all waterproofing substrates including, but not limited to: insulation materials, decks, walls, curbs, equipment, fixtures, and wood blocking. C. The applicator shall not begin installation until conditions have been properly examined and determined to be clean, dry and, otherwise satisfactory to receive specified waterproofing materials. D. During the application of specified materials, the applicator shall continue to examine all project conditions to ensure conditions remain satisfactory to complete the specified waterproofing membrane. •. •• • • • 3.02 PREPARATION Omar Cassola Residence 07 55 52-12 MOD. BITUMEN WATERPROOFING A. Before commencing work each day, the contractor shall prepare all waterproofing substrates to ensure conditions are satisfactory to proceed with the installation of specified waterproofing materials. Preparation of substrates includes, but is not limited to, substrate repairs, securement of substrates, eliminating all incompatible materials, and cleaning. B. Where conditions are found to be unsatisfactory, work shall not begin until conditions are made satisfactory to begin work. Commencing of work shall indicate contractor's acceptance of conditions. 3.03 PRIMER APPLICATION A. Examine all substrates, and conduct adhesion peel tests as necessary, to ensure satisfactory adhesion is achieved. B. Apply the appropriate specified primer to dry, compatible substrates as required to enhance adhesion of new specified waterproofing materials. C. Apply primer using brush, roller, or sprayer at the rate published on the product data sheet. Lightly prime for uniform coverage, do not apply heavy or thick coats of primer. D. Asphalt Primer: Apply (SOPREMA ELASTOCOL 500 or SOPREMA ELASTOCOL 350) primer to dry compatible masonry, metal, wood and' Other required substrates before applying heat -welded membrane elie�. P rkerr is optional for solvent based solvent -based SBS adhesives and•cements. I efer•to product data sheets. • E. Project conditions vary throughout the day. Monitor changingcbNditions, Monitor the drying time of primers, and monitor the adhesion of thg, ernbrane•pTie�. Adjust primer and membrane application methods as necessarj•td achieve•ttee desired results.• • • • •• • • 3.04 HEAT WELDING • • • • • •• • ••• • •• A. The Contractor is responsible for project safety. Where conditions are deemed unsafe to use open flames, manufacturer's alternate membrane application methods shall be used to install SBS modified bitumen membrane and flashings. Acceptable alternate installation methods include cold adhesive -applied and self - adhered membranes. Hot-air welding equipment may be used in lieu of roof torches to seal membrane side and end laps where heat welding the laps is necessary. Refer to NRCA CERTA, local codes and building owner's requirements for hot work operations. B. Single or multi -nozzle, hand-held propane roof torches shall be used to install heat -welded membrane and flashing plies. Multi -nozzle carts (dragon wagons) may also be utilized to install membrane plies. Seven (7) nozzle carts are recommended for more uniform heat application in lieu of five (5) nozzle carts. Omar Cassola Residence 07 55 52-13 MOD. BITUMEN WATERPROOFING 3.05 HEAT -WELDED, FULLY ADHERED MEMBRANE APPLICATION A. Follow material product data sheets and published general requirements for installation instructions. B. Ensure environmental conditions are safe and satisfactory, and will remain safe and satisfactory, during the application of the heat -welded membrane and flashings. C. Ensure all primers are fully dry before beginning heat -welding operations. D. Unroll membrane onto the waterproofing surface and allow time to relax prior to heat welding. E. Starting at the low point of the surface, lay out the membrane to ensure the plies are installed perpendicular to the slope, shingled to prevent back -water laps. F. Ensure all waterproofing and flashing substrates are prepared and acceptable to receive the heat -welded membrane. G. Cut membrane to working lengths and widths to conform to conditions, and lay out to always work to a selvage edge. H. Ensure specified side -laps and end -laps are maintained. End -laps should be staggered 3 ft apart. I. Direct roof torch on the roll as necessary to prevent overheating and damaging • • • • the membrane and substrates.• • J. . `.As:the membrane is unrolled, apply heat to the underside of the membrane until • •• .. • •.. • • • • • fie plastic burn -off film melts away. Continuously move the torch side-to-side • • ..:across the underside of the roll to melt the bitumen on the underside of the sheet, • • • • •• •• •evt11le continuously unrolling membrane. •• • • • • • •• • K. • *While unrolling and heating the sheet, ensure approximately '/$ to 1/2 in of hot •• •••.,• •..bUumen flows ahead of the roll as it is unrolled, and there is 1/8 to 1/4 in bleed • • • •..oidt, at all laps. •• • L. • •Adjust the application of heat to the underside of the membrane and to substrate • • •as required for varying substrates and environmental conditions. • ••• • •• ; 3.06 FLASHING APPLICATION, HEAT WELDED A. Refer to SBS manufacturer's membrane application instructions, flashing detail drawings, and follow product data sheets and other published requirements for installation instructions. Refer to manufacturer's membrane flashing detail drawings. B. The contractor is responsible for project safety. Refer to NRCA CERTA recommendations and building owner requirements for hot work operations. C. Where required to seal substrates for fire safety, install specified adhered, self - adhered or fastened backer ply to the substrate. Ensure backer -ply covers and seals all substrates requiring protection from exposure to torch operations. D. Ensure all flashing substrates that require primer are primed, and the primer is fully dry. E. Unroll the flashing base ply and flashing cap sheet onto the surface to their complete length. Once relaxed, cut the membrane to the required working lengths to accommodate the flashing height, cants and the required over -lap onto the horizontal surface. F. Cut the flashing membrane from the end of the roll in order to always install flashings to the side -lap line or selvage edge line. G. Lay out the flashing base ply and flashing Cap Sheet to offset all side -laps a minimum of 12 inches so that side -laps are never aligned on top of •tf' 4y beneath. Shingle the flashing ply laps to prevent back -water Ieps• .`•`•' • • 444 • H. Install non-combustible cant strips at transitions where required .••• ; °••• I. Ensure correct membrane and flashing sequencing to achievasedandant, multi- ply, watertight flashings. • • • • •• • • • •• • •• •• J. WATERPROOFING MEMBRANE BASE PLY: ••" • •` • • 1. Before installing flashings, install the waterproofing mambtafle bade dlly:n• the horizontal field area, and extend the base ply up tathn tqp of the Dant, • • where present, at waterproofing terminations,: trarisitionn• • •.rad penetrations. •• • • •• • 0' • K. FLASHING BASE PLY: •• • • • • • • • 1. Install the flashing base ply starting at the top leading edge of the vertical flashing substrate, down over the cant and onto the horizontal surface a minimum of 3 inches beyond the of base of the cant. Cut the base ply at corners to form 3 inch side -laps. Install gussets to seal comer transitions. 2. Install one or more flashing base ply(s) at all waterproofing terminations, transitions and penetrations. L. WATERPROOFING MEMBRANE CAP SHEET: 1. Install the waterproofing membrane Cap Sheet in the horizontal surface over the flashing base ply up to the waterproofing termination, transition or penetration, and up to the top of cants where present. 2. Using a chalk line, mark a line on the membrane cap sheet a minimum of 4 inches from the base of the cant. Where granules are present, embed Omar Cassola Residence 07 55 52-15 MOD. BITUMEN WATERPROOFING the cap sheet granules using a torch and trowel or granule embedder to prepare the surface to receive the flashing cap sheet. M. FLASHING CAP SHEET: 1. Install the flashing Cap Sheet starting at the top leading edge on the vertical substrate, over the cant and onto the horizontal surface 4 inches from the base of the cant. 2.- Install the flashing Cap Sheet to ensure a minimum two (2) ply flashing system is present at all waterproofing terminations, transitions and penetrations. N. During the membrane and flashing installation, ensure all plies are completely adhered into place, with no bridging, voids or openings. Ensure bitumen or flashing cement bleed -out is present at all flashing side and end -laps. O. Use a damp sponge float or damp rag to press -in the heat -welded flashing plies during installation. P. Where sufficient bitumen bleed -out is not present, apply specified gun -grade sealant or mastic to seal the membrane termination along all terminations, transitions and penetrations. These include gravel stop edge metal, pipe penetrations, along the top edge of curb and wall flashing, and all other flashing terminations where necessary to seal flashings watertight. Q. Fasten the top leading edge of the flashing 8 in on -centers with appropriate 1 in • • - • metal cap nails or other specified fasteners and plates. Seal fastener • •••• • . •.penetrations watertight using specified sealant or mastic. • •• •�••"• R. M�11ufacturer's liquid -applied, reinforced flashing systems shall be installed • . • •.14vbere conditions are not favorable to install SBS modified bitumen flashings. • •• • •• • • • • •Sach conditions include irregular shapes penetrating waterproofing membrane ..gdrfaces (I -beams), confined areas and low flashing heights. Manufacturer's • • • ••„• • •,liquid -applied, reinforced flashing systems are recommended in lieu of pitch pans •'•. • • • •arid lead pipe flashings. • •• •1. • For SBS modified bitumen flashings that are heat -welded or installed • •' • • using SOPREMA COLPLY EF adhesive and/or flashing cement, refer to • • •• • • • • • • manufacturer's installation guidelines for SOPREMA ALSAN RS. • S. WATERPROOFING MEMBRANE BASE PLY: 1. Before installing flashings, install the waterproofing membrane base ply in the horizontal field area, and extend the base ply up to the top of the cant, where present, at waterproofing terminations, transitions and penetrations. T. FLASHING BASE PLY: 1. Install the flashing base ply starting at the top leading edge of the vertical flashing substrate, down over the cant and onto the horizontal surface a minimum of 3 inches beyond the of base of the cant. Cut the base ply at corners to form 3 inch side -laps. Install gussets to seal corner transitions. 2. Install one or more flashing base ply(s) at all waterproofing terminations, transitions and penetrations. Omar Cassola Residence 07 55 52-16 MOD. BITUMEN WATERPROOFING U. WATERPROOFING MEMBRANE CAP SHEET: 1. Install the waterproofing membrane Cap Sheet in the horizontal field area over the flashing base ply up to the waterproofing termination, transition or penetration, and up to the top of cants where present. 2. Using a chalk line, mark a line on the membrane Cap Sheet a minimum of 4 inches from the base of the cant. Where granules are present, it is recommended to embed the Cap Sheet granules using a torch and trowel or granule embedder to prepare the surface to receive the flashing Cap Sheet. V. FLASHING CAP SHEET: 1. Install the flashing Cap Sheet starting at the top leading edge on the vertical substrate, over the cant and onto the horizontal surface 4 inches from the base of the cant. 2. Install the flashing Cap Sheet to ensure a minimum two (2) ply flashing system is present at all waterproofing terminations, transitions and penetrations. W. Apply flashing cement to the substrate and to the underside of the flashing ply using a' inch notched trowel. Apply 2.0 — 2.5 gallons per square to each surface. Application rates vary based on substrate conditions. X. During the membrane and flashing installation, ensure all plies are completely adhered into place, with no bridging, voids or openings. Ensure bitumen qr••••• flashing cement bleed -out is present at all flashing side and eri'd--laps. Y. Press -in the flashing plies during installation to ensure they argjgjkill conlctygth the substrate below. . Z. Where sufficient bitumen bleed -out is not present, apply speciOCI•jun-gra, •• sealant or mastic to seal the membrane termination along all wafer] oofing• "• terminations, transitions and penetrations. These include graveL§tQl5 edgep ts1, pipe penetrations, along the top edge of curb and wall flashingriar/C►pll other • flashing terminations where necessary to seal flashings waterftght. ' • AA. Fasten the top leading edge of the flashing 8 inches on-centersaiitri:apprgariate. 1 in metal cap nails or other specified fasteners and plates. Seal fastener penetrations watertight using manufacturer's sealant or mastic. BB. Manufacturer's liquid -applied, reinforced flashing systems should be installed where conditions are not favorable to install SBS modified bitumen flashings. Such conditions may include irregular shapes penetrating surfaces (I -beams), confined areas and low flashing heights. Liquid -applied, reinforced flashing systems are required in lieu of pitch pans and lead pipe flashings. 1. For SBS modified bitumen flashings that are heat -welded or installed using SOPREMA COLPLY EF adhesive and/or flashing cement, refer to manufacturer's installation guidelines for SOPREMA ALSAN RS. Omar Cassola Residence 07 55 52-17 MOD. BITUMEN WATERPROOFING 3.07 LIQUID -APPLIED, PMMA (PMA) MEMBRANE AND FLASHING SYSTEM APPLICATION ALSAN RS (ALSAN RS LO) A. Refer to manufacturer's details drawings, product data sheets and published general requirements for application rates and specific installation instructions. B. Pre-cut SOPREMA ALSAN RS FLEECE polyester reinforcing fleece to conform to waterproofing terminations, transitions and penetrations being flashed. Ensure a minimum 2 in overlap of fleece at side and end -laps. Ensure the completed liquid -applied flashing membrane is fully reinforced. C. Apply the.base coat of catalyzed SOPREMA ALSAN RS resin onto the substrate using `a brush or roller, working the material into the surface for complete "coverage and full'adhesion. D. Immediately apply the SOPREMA ALSAN RS FLEECE reinforcing into the wet base coat of resin. Using a brush or roller, work the (SOPREMA ALSAN FLEECE reinforcing fabric into the wet resin while applying the second coat of catalyzed SOPREMA ALSAN RS resin to completely encapsulate the fleece. 3.08 CLEAN-UP ..•- . • • ••• • 3.Q9 • WAIMIISTING A. Clean-up and properly dispose of waste and debris resulting from these operations each day as required to prevent damages and disruptions to .•.op$rations. • • • •• •• • • •• •••• • •• • A. • • • • • ••• •• 'Water Testing per ASTME D 5957, with 2 inches of water for 24 hours. No leaks •••&t14uld be observed. • END OF SECTION • • • • • • • • • • •• • • • • • ••• • • •• Omar Cassola Residence 07 55 52-18 MOD. BITUMEN WATERPROOFING 4 M IAM I DiADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE OA) Soprema, Inc. 310 Quadra) Drive Wadsworth OH 44281 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.gov/economv This NOA is being issued under the applicable le nd r gul materials. The documentation submitted has been reviattm Product Control Section to be used in Miami Dade County and of Authority Having Jurisdiction (AHJ). This. NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to • • • • meet the requirements of the applicable building code. •• • ••• • .• • This product is approved as described herein, and has been designed to comply with thellbrida Beilding Code including the High Velocity Hurricane Zone of the Florida Building Code. • truction unty RER - the •••• DESCRIPTION: Soprema Modified Bitumen Roofing Systems over Concrete tracks. • •• • • • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name gr.1Ugp' city, stg „ and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted . herein. • • • RENEWAL of this NOA shall be considered after a renewal application has been filed add there•has been no change in the applicable building code negatively affecting the performance of this product • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0603.07 and consists of pages 1 through 160. The submitted documentation was reviewed by Jorge L. Acebo. MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 1 of 160 • .• . . . ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: Roofing Modified Bitumen SBS Concrete -525 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Sopra G Dimensions 39" x 108' (3.5 sq.) Test Specification ASTM D4601 Modified Sopra G 39" x 108' (3.5 ASTM D4601 sq.) Soprabase 39" x 99' (3 sq.) ASTM D4601 • . .... . Sgprabase S • •..'39" x 65' (2 sq.) ASTM D4601 • . . .• . • 93.10.11/ „• • 56” x 180' (5 sq.) ASTM D2178 • • Type IV • .• . . . • staid . • . 00* • . • . • • ;36" x 180' (5 sq.) • . . . .. Elastophene Stick 39" x 49' (1.5 sq.) Elastophene Flam 39" x 49' (1.5 sq.) Stick Sopralene Flam 39" x 49' (1.5 sq.) Stick Sopralene Stick MIAMI•DADE COUNTY APPROVED ASTM D2178 Type VI ASTM D6163 ASTM D6163 ASTM D6164 Product Description Fiberglass reinforced oxidized asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Fiberglass reinforced modified asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Oxidized asphalt, polyester reinforced, sand - surfaced base sheet. For use as a base/ply sheet only. SBS modified bitumen, polyester reinforced, sand -surfaced base sheet. For use as a base/ply sheet only. Type IV fiberglass reinforced, smooth surfaced plysheet used in multi -ply systems and complies with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Type VI fiberglass reinforced, smooth surfaced plysheet used in multi -ply systems and complies with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Self -adhered, sanded surfaced, fiberglass reinforced membranes. Self -adhered, sanded surfaced, fiberglass reinforced membranes. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. 39" x 33' (1 sq.) ASTM D6164 Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 2 of 160 Product Dimensions Colphene Stick 39" x 33' (1 sq.) Colvent SA Colvent TG Colvent 180 TG Colvent Flam TG 39" x 49' (1.5 sq.) 39" x 49' (1.5 sq.) 39" x 33' (1 sq.) 39" x 49' (1.5 sq.) Test Specification ASTM D6164 ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6163 Colvent Flam 180 39" x 33' (1 sq.) ASTM D6164 TG Elastophene 39" x 49' (1.5 sq.) Sanded Colphene Sanded 39" x 49' (1.5 sq.) Elastophene 39" x 49' (1.5 sq.) Sanded 2.2 Elastophene 39" x 33' (lsq.) Sanded 3.0 Elastophene HS 39" x 66' (2 sq.) ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 Elastophene PS 39" x 49' (1.5sq.) ASTM D6163 MIAMI•DADE COUNTY APPROVED Product Description Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied self - adhering strips on back side Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. Polyester reinforced, modified bitumen membrane with 1" wide factory applied heat weld strips on back side. Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied heat weld strips on back side and a plastic burn -off film surface. Polyester reinforced, modified bitumen membrane with 1" wide factory applied he • • • • weld strips on back side and Cplastip burn-d'ff• • • film surface. • • • •• Fiberglass reinforced modifted•biitt>Knen • membrane sanded on both siddS' implied arr pot► asphalt, cold adhesive or ribboft Mpping. • • • • • Fiberglass reinforced modified birt+men e•••••• membrane sanded on both skip, etcplied in het asphalt, cold adhesive or ribbt7n stripping. • • • • • Fiberglass reinforced modifie'd•biiui3ien • • • • membrane sanded on both sides. Applied in hot: asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripped. Fiberglass reinforced modified bitumen membrane with fire retardants and sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 3 of 160 • • • Test Product Product Dimensions Specification Description Elastophene PS 3.0 39" x 49' (1.5sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene SP 2.2 39" x 49' (1.5 sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Colphene SP 2.2 39" x 49' (1.5 sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Elastophene SP 3.0 39" x 49' (1 sq.) ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn- • • • • off film).• • •••• CQlphppe SP 3.0•..•39" x 49' (1 sq.) • . . .. • . • . . • . • .• •• • • •• • • .•.. • •••• ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). gietophene Flare ..39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen • membrane covered on both sides with a plastic . • • • • burn -off film. Applied by heat welding. ▪ • • Fjastpphene Ftai 4.19" x 49' (1.5 sq.) ASTM D6163 Fiberglass reinforced modified bitumen 2.2 • membrane covered on both sides with a plastic burn -off film. Applied by heat welding. Elastophene Flam 39" x 33' (1 sq.) ASTM D6162 Woven fiberglass/polyester composite reinforced HS modified bitumen membrane with fire retardants and plastic burn -off film on both sides. Applied by heat welding. Elastophene HS 62 39" x 33' (1 sq.) ASTM D6162 Woven fiberglass/polyester composite reinforced modified bitumen membrane with sanded surface on both sides. Applied in hot asphalt, cold adhesive. Elastophene 180 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified Sanded bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. MIAMI.OADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 4 of 160 i Test Product Product Dimensionsecif Spication Description Colphene 180 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified Sanded bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene 180 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified PS bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Colphene 180 PS 39" x 49' (1.5 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene GR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Elastophene LS FR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen GR membrane with fire retardants, sanded on tile• • • bottom and mineral granules en the top. A'lply�l' in hot asphalt, cold adhesive on Ribbon stripping, •• • • • Elastophene FR 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modifi .d lRnmen • • • • GR membrane with fire retardants,led on the • • bottom and mineral granules bu tbetop. API/lied in hot asphalt, cold adhesive of sibbon striping.. ' • Elastophene FR+ 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modifierc� pint men • • • • • • • GR membrane with fire retardant$, stncted on the • bottom and mineral granules on the top. R1S1511&d in hot asphalt, cold adhesive ol<r blaon stri ing.. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen GR membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen LS FR GR membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Elastophene Flam 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen FR GR MIAMFDADE COUNTY APPROVED membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 5 of 160 • • • . . Product Elastophene Flam FR+ GR Sopralene 180 Sanded Sopralene 250 Sanded Sopralene 180 Sanded 2.2 Sopralene 180 PS ... • Dimensions 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 26' (3/4 sq.) 39" x 33' (1 sq.) 39" x 26' (% sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) Sepraiene 18Q P$ 39" x 49' (1.5 sq.) -,.. .. .. .. . . . 1 • . .1 1111 . 1 ••• .. . 1111 1 • • • • $opralene 184 SP...39" x 33' (1 sq.) 1.S.••1 • . • . Gol• 'phene 180 SP 3.5 .1 • • • • • • • • • .. Sopralene 180 SP 3.0 Sopralene 250 SP 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) Soprafix Base 610 39" x 30' (1 sq.) MIAMI-DADE COUNTY APPROVED Test Specification ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6162 Product Description Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt or cold adhesive. Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the top and sanded on the bottom. Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Composite reinforced modified bitumen membrane with a film surface. Applied by mechanical attachment. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 6 of 160 3 Product Soprafix Base 611 Soprafix Base 630 Soprafix [S] Dimensions 39" x 33' (1.5 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) Soprafix Base 612 39" x 33' (1 sq.) Soprafix [F] Soprafix Base 613 Soprafix [X] Soprafix Base 614 Soprafix Soprafix Base 622 Soprafix-e MIAMI•DADE COUNTY APPROVED 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) Test Specification ASTM D6164 ASTM D6162 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with a film surface. Applied by mechanical attachment. Composite reinforced modified membrane with a film surface. Applied by mechanical attachment. Non -woven polyester reinforced modified bitumen membrane. Applied by mechanical attachment. Non -woven polyester reinforced bitumen membrane. Applied by attachment. Non -woven polyester reinforced bitumen membrane. Applied by attachment. Non -woven polyester reinforced bitumen membrane. Applied by attachment. Non -woven polyester reinforced bitumen membrane. Applied ay attachment. Non -woven polyester reinforce bitumen membrane. Applied% attachment. modified mechanical modified mechanical modified mechanical .•.• n3odified•••••• tnephanicol • • • ••• • mo • dified • • aechanigal • • • • • Non -woven polyester reinforced modified • �' bitumen membrane with a 4 inc1Yor• 5 -inch wide side lap with a plastic burn -off filly on till bottom and sanded on the toll. Anted by.. • mechanical attachment. Lap heat welded or •.: sealed with an approved cold adhesive. Non -woven polyester reinforced modified bitumen membrane with a 4 -inch or 5 -inch wide side lap with a plastic burn -off film on the bottom and sanded on the top. Applied by mechanical attachment. Lap heat welded or sealed with an approved cold adhesive. Non -woven polyester reinforced modified bitumen membrane with a 5 -inch wide side lap with a self -adhering compound and release film and sanded on the bottom and top surfaces. Applied by mechanical attachment. Lap self - adhered or sealed with approved cold adhesive. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 7 of 160 Test Product Product Dimensions Specification Description Soprafix Base 641 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with a 5 -inch wide side lap with a self -adhering compound and release film and sanded on the bottom and top surfaces. Applied by mechanical attachment. Lap self - adhered or sealed with approved cold adhesive. Soprafix Cap FR- 39" x 33' (1 sq.) ASTM D6163 Fiberglass reinforced modified bitumen 651 membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced SBS modified 180 bitumen membrane, both sides covered with a plastic burn -off film. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced SBS modified 180 bitumen membrane, both sides covered with a plastic burn -off film. Applied by heat welding • • • • or ribbon stripping (after removal of plastic • • • • • • • burn -off film). • • • • • • Sopfialdne Flare.. • • 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced SBS modified • • 250 bitumen membrane, both sides covered with a • • • • •••• plastic burn -off film. Applied by heat welding •• • • • • • • • • • •••• or ribbon stripping (after removal of plastic • • • ' • • • burn -off film). ••• ••• •• • •• Sopralene 180 Fi• 4 •. 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified • GR • bitumen membrane with fire retardants a sanded • • • • • bottom and a mineral granules top. Applied in •• •"' hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Colphene 180 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Sopralene 180 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified FR+ GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 8 of 160 t Test Product Product Dimensions Specification Description Sopralene 180 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified Ultra FR GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Sopralene 250 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Colphene 250 FR 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Sopralene 250 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified Ultra FR GR bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbq}r, • • • stripping (after removal of plastic burn -off MM.* • • Sopralene 250 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced odified: •. •' • FR+ GR bitumen membrane with fire ttetlatdants a sanded • bottom and a mineral granules'ttr.Appli{d jn•. • • hot asphalt, cold applied adhegiWor ribbdn • • stripping (after removal of pfasAioburn-off iilm) Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinfoi dpnQdified •• • 180 GR bitumen membrane with a plastic born -off tijlp; on the bottom and mineral granules.on the top. •• Applied by heat welding or rigion stripping'..: . • (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 GR bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 GR 3.5 bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). MIAM RADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 9 of 160 Test Product Product Dimensions Specification Description Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR GR 3.5 bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 Ultra FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules •••• on the top. Applied by heat welding or ribbon • 6009 • • • •• • stripping (after removal of plastic burn -off film). • . . •. . • .. • Sopr'hle:he Flaw, • • •39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified • • 250.FR GR • bitumen membrane with fire retardants a plastic • • •• • ••• • • • • burn -off film on the bottom and mineral granules •••• • • •' • on the top. Applied by heat welding or ribbon • • •• • •' • . . stripping (after removal of plastic burn -off film). .. .. .. • • Colphene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified • 250 FR'GR • • • bitumen membrane with fire retardants a plastic • burn -off film on the bottom and mineral granules ••• •"' • • • •. on the top. Applied by heat welding or ribbon •• stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 250 Ultra FR GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 180 FR+ GR bitumen membrane with fire retardants a plastic MIAMI.DADE COUNTY APPROVED burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 10 of 160 1 Test Product Product Dimensions Specification Description Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified 250 FR+ GR bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Sopralene Flam 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified Antirock bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Elastophene Stick 39" x 33' (1 sq.) ASTM D 6163 Self -adhered, granule surfaced, fiberglass FR GR reinforced membranes. Colphene FR GR 39" x 33' (1 sq.) ASTM D 6163 Self -adhered, granule surfaced, fiberglass reinforced membranes. Elastophene Stick 39" x 33' (1 sq.) ASTM D 6164 Self -adhered, granule surfaced, polyester HR FR GR reinforced membranes. Colphene HR FR 39" x 33' (1 sq.) ASTM D 6164 Self -adhered, granule surfaced, polyester GR reinforced membranes. Sopralast 50 TV various ASTM D6298 Fiberglass reinforced modified bitumen she tjgg • Alu faced with aluminum foil. A1Spli2d by heat. • • • welding of ribbon stripping r removall'of .. • • plastic burn -off film). • • • • Sopralast 50 TV various ASTM D6298 Fiberglass reinforced modifi2t.ijyfien shhet!ig• • 12 Alu Sanded sanded on the bottom and fac' l,wj h aluminum . • • foil. Applied in hot asphalt, li•adhesive or. •.: • ribbon stripping. • • • • • Soprastar Flam 39" x 33' (1 sq.) ASTM D6162 Polyester reinforced SBS modified bitumen• • • • • • membrane with a plastic burnt off fism on Ow. • • bottom side and a reflective white top surface.'.: Applied by heat welding. Soprastar Sanded 39" x 33' (1 sq.) ASTM D6162 Stabilized polyester mat reinforced SBS modified bitumen membrane with a sanded bottom side and a reflective white top surface. Applied by hot asphalt or cold adhesive. Soprastar Stick 39" x 33' (1 sq) ASTM D6162 Polyester reinforced SBS modified bitumen membrane with a release film covered self - adhering bottom side and a reflective white top surface. UNILAY 39" x 33' (1 sq.) ASTM D6164 Non -woven polyester reinforced modified bitumen membrane with fire retardants and surfaced with mineral granules. Applied by mechanical attachment, heat welding or ribbon stripping (after removal of plastic burn -off film). MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 11 of 160 Product Elastocol 500 Elastocol Stick Elastocol Stick Zero ALSAN FlashingTM ALSAN Polyfleece COLPLY Flashing Cement Soprawalk Dimensions various various Various 1.25 gallon pail or 3.75 gallon pail 4", 8" or 39" wide by 50' long 5 gallon pail 39" x 26' (3/4 sq.) I -ii i elocity®• 4 dual cartridges In4ulati9n ; • •. • per carton A•de%ile III • (HUTA-III) • High 1ocity®• • • • •4 dual cartridges InsMatian • • • • per carton A[lhesirve III —. • • •• •• • Grreen • High Veilocity; • :5 gal. or 50 gal. IristdatVjn . Aclhesiwe PG : •.. • D:aoTack 5, 50 gallon pail Duotack Neo COLPLY Adhesive COLPLY Modified Adhesive COLPLY EF Adhesive Sopravap'r MIAMIDADE COUNTY APPROVED 5, 50 gallon pail 5 gallon pail or 55 gallon drum 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail 45" x 133' Test Specification ASTM D41 ASTM D41 ASTM D41 Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Product Description Asphalt primer. Asphalt primer. Asphalt primer. One part polyurethane/bitumen resin, moisture cure compound. Non -woven polyester reinforcement used in the ALSAN Flashing system. Elastomeric bitumen based mastic compound. Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and mineral granules on the top. Applied by hot asphalt, cold adhesive or ribbon stripping. Two part elastomeric urethane foam adhesive. Two part elastomeric urethane foam adhesive. Proprietary Two part elastomeric urethane foam adhesive. Proprietary Proprietary Proprietary Proprietary Proprietary Various Two part elastomeric urethane foam adhesive. Two part polyurethane foam adhesive. Polymer modified cold process membrane adhesive. Elastomeric bitumen based cold adhesive. Solvent free, polymeric adhesive. Self -adhering air/vapor barrier membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 12 of 160 APPROVED INSULATIONS: Product Name ACFoam-II, ACFoam-III ACFoam Composite ISO 95+ GL EnergyGuard Polyiso Insulation EPS XPS High Density Wood Fiberboard Perlite Insulation DensDeck, DensDeck Prime Sopra-ISO s, Sopra-ISO+ s M -Shield, M -Shield CG Sopra-ISO r, Sopra-ISO+ r Sopra-ISO x H -Shield, H -Shield CG ENRGY 3, ENRGY 3 25 PSI, ENRGY 3 AGF, ENRGY 3 CGF Ultra -Max, Multi -Max FA -3 SECUROCK Gypsum -Fiber Roof Board Structodek High Density Fiberboard Roof Insulation Fesco Board Sopraboard DEXcell FA Glass Mat Roof Board DEXcell Cement Roof Board MIAMI.DADE COUNTY APPROVED TABLE 2 Product Description Polyisocyanurate foam insulation Composite polyisocyanurate insulation board Polyisocyanurate foam insulation Composite polyisocyanurate insulation Type IX 1.8 pcf. Polystyrene Insulation Type IV 1.6 pcf. Polystyrene Insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Gypsum board High Density wood fiber insulation board Expanded mineral fiber insulation Mineral fortified asphaltic cored coverboard Gypsum board Cementitious insulation board Manufacturer (With Current NOA) Atlas Roofing Corporation Atlas Roofing Corporation Firestone Building Products Company, LLC GAF Generic Generic Generic Generic Georgia Pacific Gypsum LLC Soprema, Inc. Soprema, Inc. Soprema, Inc. • • • • • • .... S8wen$, Inc. • • • • Hunt-VI:MN, LLC •• Johns lyjajyrille CWy. •• . • . . . 1••. • •• RMax ueia�ing, LCC. .. .. .. .. ••G•orp. • • . Blue Rike•F•iberboard•i • Inc. • • •• Johns Manville Corp. Soprema, Inc. National Gypsum Company National Gypsum Company NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 13 of 160 • • • • • • • • • APPROVED FASTENERS: Fastener Product Number Name 1. Soprema #12, #14 & #15 Fastener 2. Dekfast 12, 14 & 15 HS 3. Dekfast Galvalume Steel Hex 4. Dekfast DekFlat Round Plastic Lock Plate 5. AccuTrac Hextra 6. OMG 3" Galvalume Steel Plate 7. OMG Flat Bottom Metal Plate # 12.Standard Roofgrip, • .. #1: 1tiaatrip & #15 '• • • . Ron( slip• • • R • • 9. •..•10: F1ut€idriail • 1.1. 3 ix. is and Metal Plate •••• •• • •• 12. OM€rFlestic Plate • • • • • 13! Tri ait #:4 HD Fas'tener' • • • •.. • • .•• 14. Trufast #15 EHD Fastener 15. Trufast 3" Metal Insulation Plate 16. OMG Polymer Batten Strip 17. Dekfast Galvalume Steel 3" Round 18. Dekfast Coiled Batten Strip 19. Dekfast 2" Round Barbed Seam Plate 20. Soprema 3" Round Insulation Plate MIAMI.DADE COUNTY APPROVED Table 3 Product Description Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Insulation fastener Galvalume AZ50 steel plate Polypropylene locking plate. Insulation fastener for wood and steel. Galvalume stress plate. Galvalume stress plate. Insulation fastener. Insulation fastener. Insulation fastener. Galvalume AZ50 steel plate Polypropylene stress plate Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Galvalume AZ50 steel plate Modified polymer batten bar Galvalume AZ50 steel plate Batten bar Stress plate Stress plate Dimensions 2 78" x 3 '/d, 3"x3'/4" 3" diameter 3" square 3" diameter 3.25" diameter Manufacturer (With Current NOA) Soprema, Inc. SFS Intec, Inc. SFS Intec, Inc. SFS Intec, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. 3" diameter Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. 3" diameter SFS Intec, Inc. SFS Intec, Inc. 2" diameter SFS Intec, Inc. 3" diameter Soprema, Inc. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 14 of 160 APPROVED FASTENERS: Fastener Product Number Name 21. Soprafix 2" SB Stress Plate 22. Soprafix 2-3/8" SB Stress Plate Soprafix MBB -R Soprema #12 DP, #14 MP, #15 HD Fastener 25. Trufast Flat Batten Bar 23. 24. 26. Trufast Recessed Batten Bar 27. #15 Roofgrip Large Head 28. Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed Plate 29. Trufast 2" Barbed Metal Seam Plate 30. Trufast 2.4" Barbed Metal Seam Plate 31. Dekfast IF -2 -SB 32. Soprema 2" Seam Plate 33. Soprema 3" Metal Installation Plate 34. Trufast 3" Recessed Metal Insulation Plate 35. OMG Heavy Duty 36. OMG 2-3/8" Barbed XHD Plates 37. Trufast 2.4" Scoop Seam Plate 38. Soprema 2.4" Seam Plates MIAMI•DADE COUNTY APPROVED Table 3 Product Description Stress plate Stress plate Metal Batten Bar Insulation and membrane fasteners Galvalume AZ55 steel batten bar Galvalume AZ55 steel batten bar with recessed holes Carbon steel fasteners used in steel, wood and concrete decks Galvalume AZ55 steel barbed plate Galvalume steel barbed plate Galvalume steel barbed plate Galvalume AZ55 steel plate Stress plate Stress plate Galvalume AZ50 steel plate Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Galvanized steel stress plate Galvalume steel stress plate Galvalume steel stress plate Dimensions 2" diameter 2-3/8" diameter Various 2-3/8" diameter 2" diameter 2.4" diameter 2" diameter 2" diameter 3" diameter 3" diameter Various 2-3/8" round 2.4" Round 2.4" Round Manufacturer (With Current NOA) Soprema, Inc. Soprema, Inc. Soprema, Inc. Soprema, Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. SFS Intec, Inc. •... • • .•.. Prltenloh, Brisk & • • �a.•U.S., enc...' 41ai3loh, Brinck'& ..cp'U.S., ono. ••S. IIntec,In i • .. •. • • .. Suprema, Incl • . . Soprema,�IN... • • . . • ••. . Altenloh, Brinc)td$ Co. U.S., Inc. OMG, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. Soprema, Inc. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 15 of 160 • • •••..• •.... . • •.•.• •.•.•. • • • •..•.• • • ••..•. • • APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Manufacturer Number 1. Generic •••• • • .••• 2. Soprema, Inc. 3. Karnak Corporation 4. Soprema, Inc. 5. Thermo Manufacturing Systems, LLC 6. Quest Construction Products LLC dba United •Coatings • • • • • Insulating Coatings 00000 • •(;gyration • • • •• • • • •• •• • • •• S. • • • • • •• •• • 9. •.•••• • • •.1•°• •• 11. • • Venil Company •...• • •• •• :Mttit ial Coating Corp. Soprema,• Inc. Generic MIAMFDADE COUNTY APPROVED Application Flood coat and gravel/slag with an application rate of 60 lbs./sq. & 400 lbs./sq., respectively. Gravel applied at 400 lbs./sq., adhered with COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 4 gal./sq. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal./sq. Cural Aluminizer applied at an application rate of 2 gal./sq. Super Prep Elastomeric Roof Maintenance Coating applied in two coats at an application rate of 1.5 gal./sq./coat. United Coatings Roof Mate Coating, applied in one base coat at a rate of 1.5 gal./sq., and one finish coat at a rate of 1.5 gal./sq. Astec 2000 Finish Coat applied in two base coats at a rate of 0.75 gal./sq./coat and two finish coats at a rate of 0.75 gal./sq./coat. HE280DC White Elastomeric Roof Coating applied in two coats at an application rate of 1 gal./sq./coat. Acryshield® A500 applied in two coats at an application rate of 1 gal./sq./coat. R Nova Plus applied in two coats. Base coat is applied at 3 gal/sq. (1.2 L/m2) and allowed to dry. A top coat is applied at 1 gal/sq. (0.4 L/m2). Semi -ceramic coated colored granules. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 16 of 160 EVIDENCE SUBMITTED: Test Agency/Identifier Florida Testing Engineering & Consulting Inc. Factory Mutual Research Corp. Underwriters Laboratories Dynatech Engineering Corp. MIAMFDADE COUNTY APPROVED Report TAS 114-D TAS 114-D 1W8A1.AM 1Z3A6.AM 3000507 3009610 3008869 3002351 3017614 3025860 3029098 3032109 3026128 3024311 3036182 3014751 3023458 3023749 3031818 3X3A7.AM 3045101 3037437 3008441 3044630 3042559 3047439 3045734 3046765 3047351 3051408 3054633 RR203650 3044801 3053841 3051109 3053475 RR203157 RR201595 RR203472 R11436 10.94.27 2491-04.95 Name GL0904-02 GL0409-03 FM 4470 FM 4470 FM 4450 FM 4450 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 UL 790 TAS 114 TAS 114 Date 05/01/09 05/01/09 07/15/93 04/27/95 02/16/00 • 10/22/01 03/19/01 02/28/03 02/27/06 04/17/06 10/25/07 07/21/08 08/04/06 11/01/06 07/31/09 08/27/03 07/18/06 09/28/06 02/20/•09' • • .'.09/08/91' • • •••S•.11/05Z1`Z • 11/09/09 • • 10/17140 °••..'02/1(1712.•• •••••.10/18/11 • • • • • 07/2/41.3..: 04/04/12* • • 02/441.1 • • 10/09/14 08/1'3%f4 12/18/15 • 12/18/15 02/27/12 03/27/15 05/11/15 02/11/16 11/06/15 06/17/15 02/05/16 06/18/13 10/27/94 01/04/95 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 17 of 160 •••••• • • • ...... ...... ....• • ..... ...... • • • ...... • • ...... •• • • • • • • • • . • • ••••• • • •.••• ••••.• •• • •••••. • • • .. • • • EVIDENCE SUBMITTED: (CONTINUED) Test Agency/Identifier Exterior Research & Design, LLC Trinity I ERD ••. • • • • •••• •• . • • •• • •• . • • •• • • • • • • •• •• •••••• • • •.• • • .. • • •• • •• •• •.•••• •••••• •••• • • •••• ..•S•• • • •• •• •••••• • • • • • • • •• . • • • .. MIAMI.DADE COUNTY APPROVED Report 2003.02.97-1 2003-2.04.97-1 2002.07.97-1 2755.09.02 2760.01.05-3 2761.09.03 2761.10.03-2 2777.09.05-R2 2774.04.05-R1 S12370.03.09-1 S12370.03.09-2 S12370.03.09-3 C8500SC.11.07-R1 S11440.06.10 S32840.06.10 -R1 S11440.01.11 -R1 S11440.11.10-4 S11440.12.10 -1-R1 543210.11.14 S45520.11.13 -R2 539500.12.12-R1 S39320.01.12 -R1 547170.11.14 S32700.12.10 -R2 535860.12.11-1-R1 S35860.12.11-2 S35860.05.12 -1-R2 S35860.05.12 -2-R3 S35860.05.12-3 S35860.09.12 -R2 S 14000.08.09-R2 539970.07.12-2 S39970.07.12 -R1 539970.07.12 -1B -R1 547160.01.14-R1 545010.02.14 543400.08.14-5 S43400.08.14-6 543400.08.14-7-R1 543400.09.14-9 S43400.09.14-10 S45010.02.14 S43400.08.14 -4-R1 S44110.09.14-3 Name TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM D6164 ASTM D6164 ASTM D6162 TAS 117(B) ASTM D6862 ASTM D4798 TAS 110 TAS 117 (B) ASTM D6164 ASTM D2178 ASTM D6163 ASTM D1876 Physical Properties Physical Properties FM 4474 & TAS 114 FM 4474 & TAS 114 ASTM D6162 ASTM D2178 ASTM D4601 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6163 TAS 114 ASTM D6164 ASTM D6162 ASTM D6162 FM 4470 & TAS 114 (H) ASTM D6506 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6298 ASTM D6506 ASTM D6163 ASTM D6163 Date 02/15/97 04/15/97 08/15/97 10/19/02 02/22/05 09/02/03 10/03/03 05/24/02 04/18/07 03/06/09 03/06/09 03/06/09 08/07/09 06/01/10 12/11/14 06/07/12 11/17/10 06/07/12 11/10/14 03/26/14 12/27/12 05/24/12 11/10/14 07/07/14 12/12/14 12/12/11 02/14/13 08/28/14 05/08/12 12/12/14 10/09/09 07/12/12 12/12/14 12/12/14 12/11/14 02/07/14 08/26/14 08/26/14 11/20/14 09/02/14 09/08/14 02/07/14 10/24/14 09/08/14 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 18 of 160 EVIDENCE SUBMITTED: (CONTINUED) Test Agency/Identifier Trinity I ERD PRI Construction Materials Technologies, LLC MIAMI-DADE COUNTY APPROVED Report S44110.09.14 -7C 544220.09.14-1 S44220.09.14 -7A S11440.11.10 -3-R2 539500.02.12 SOP -049-02-01 SOP -043-02-01 SOP -042-02-01 SOP -041-02-01 SOP -040-02-01 SOP -010-02-01.03 SOP -050-02-01 SOP -056-02-01 Name ASTM D6164 ASTM D6162 ASTM D4601 ASTM D4601/TAS 117(B) Physical Properties ASTM D1644 / D2196 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 TAS -138 ASTM D3019 Various Date 09/02/14 09/08/14 09/08/14 08/26/14 02/23/12 05/31/12 02/27/12 02/27/12 02/27/12 02/27/12 07/26/11 07/12/12 09/12/12 • • • • • •• • 000000 • •••••• •••• • • •••• •••.•• • • •• •• ••••.• •• • • • • • • .• •• • • .•• • • •••• •• • • • • • •• •• • •• • • • • • •• • • • • • ••• •• • • • •••••• • ••• • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 19 of 160 •••••• • • • •••••• • • •••••• ••••• • • ••••• 000000 • •••••• • • • •••••• • • APPROVED ASSEMBLIES: Membrane: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(1): One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto concrete deck. All General and System Limitations apply. Vapor Barrier: Two plies of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded fully adhered in COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 gal/sq. over concrete deck primed with asphaltic primer at 0.75 gal/sq. (Meets Maximum Design Pressure of -120 psf. See General Limitation #9) ...• . • •.•••• •.•• • • • • . .. . .• • .• . . • • • • • ...•. ••••• O e br more:l'al¢ ts:of any of the following insulations. ...... •as'e•Insulation 1 yer (Optional) Insulation Fasteners Fastener • • • •• • (Table 3) Density/ft2 ...... ��Iritld, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoam-III, ...... opra;ISO s; S'opra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, ,j'QRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation Minimum 1.5" thick (flat or tapered) N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 • • •. • . • •. • . . •• • ...... ...... ...• • • .... Or One ply of Sopravap'r, self -adhered to concrete deck primed with Elastocol Stick Zero at 0.5 gal/sq. (Meets Maximum Design Pressure of —240 psf. See General Limitation #9) Or Two plies of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded or Sopralene 250 Sanded fully adhered in COLPLY EF Adhesive applied at a rate of 1.5 gal/sq. (Meets Maximum Design Pressure of —270 psf. See General Limitation #9) SECUROCK Gypsum -Fiber Roof Board Minimum '/4" thick N/A N/A Note: Top layer of insulation shall be adhered with Duotack or Duotack Neo applied in '/z" to 3/4" wide ribbons spaced 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 20 of 160 Base Sheet: Ply Sheet: (Optional) MIAMI.DADE COUNTY APPROVED One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered to substrate primed with Elastocol Stick Zero. *Requires torch -applied ply or cap membrane One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophorne, HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*;E1 tgphene 1,8()• Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase,• :•• •. Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2* opralene'180' • Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered injtoLasphalt 4. 25� lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesi0e,.GQLPLY! •. • • Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. •••••• • • •• Or •••... • One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophtnd SP 2.;, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0' • • • Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 1900,. dolphena • . Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam'.: TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered. *Requires torch -applied ply or cap membrane NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 21 of 160 ...... . . . .••... • • •..•.• • • •••.. •OOOOO •••••• • • • •••••• • . ••••.. ...... Membrane: Surfacing: •... • • 1111 • Maximum • 1:111. •Presse re: •.i••• • • • • • Design • 1114,•• • • •••..• • •• ••••• • • • • . 1 •••• •...•• • •1 • •••... •00000 • • •1111. .• •• .. .. • • • .1.•11 • • . 11111 • .11 . •• • • • • •• • • .•.•.• • • • •. • Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. See Vapor Barrier Options Above. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 22 of 160 J Membrane Type: Deck Type 3I: Deck Description: System Type A(2): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto concrete deck. All General and System Limitations apply. Vapor Barrier: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded fully adhered in COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 gal/sq. over concrete deck primed with asphaltic primer at 0.75 gal/sq. (Meets Maximum Design Pressure of —135 psf. See General Limitation #9) Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded or Sopralene 250 Sanded fully adhered in COLPLY EF Adhesive applied at a rate of 1.5 gal/sq. over concrete deck primed with asphaltic primer at 0.75 gal/sq. (Meets Maximum Design Pressure of —270 psf. See General Limitation #9) •••• One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners • • • • • . • • (Table 3) . •.:.pensity/ftp •• • • • •••. • •Fastener •. H -Shield, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoar�►=ILJ, :•• • Sopra-ISO s, Sopra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3; • • • • • • • ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation .• • .• •• • ••• . Minimum 1.5" thick N/A ...... N/A • • Top Insulation Layer •. • •• • . Insulation Fasteners •• FastiMe • • • •• . • • •Densitybft2 • . • (Table 3) Sopraboard Minimum 1/8" thick N/A DEXcell FA Glass Mat Roof Board, DensDeck, SECUROCK Gypsum -Fiber Roof Board Minimum 1/4" thick N/A DEXcell Cement Roof Board Minimum 7/16" thick N/A N/A N/A N/A .• Note: All insulations shall be adhered to the vapor barrier with Duotack or Duotack Neo applied in %%" to %" wide ribbons spaced maximum 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 23 of 160 • •• ...... • . ••..•• • • ••••. • . ••... •..... • • • •.•.•• • • •••••. Base Sheet: One or two plies of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch - applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied ply or cap membrane. Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, • ' �Q�kional) • • Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene •••••• • •• • •• HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 •• •' .. • •• • • • • • Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, • • , •••••• Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 •• • • • •; • • • • •• ••' . PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or in COLPLY • '•••• ••••• • • • Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. • .• •• •••••• ••••• • •• Or •• ••••• •, .••••• • •• •••••• • • •••••• • •••••• • • ••• • • •••••• • • • • • • • • • • • •• MIAMFDADE COUNTY APPROVED One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 24 of 160 Membrane: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. See Vapor Barrier Options Above. • • • • • •• • •••••• • •••.•. •••• • • •••• • • •••• .••••. •• • • •• •• • • • •• • •• • • • • • •• • 000000 • • •••••• • • 00000 •••.•• • • • • • • • • ••••. •• •• •• •• OOOOOO ••.••• • • • • • • • • • • • • •••••• • • • • • • •• • ••• • •••.••• • • • • ••.••• NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 25 of 160 000000 • • • 1111.• •••••• • • .••1• • • ••1•. •1•••• • • • •1111• • • •.••.• Membrane Type: Deck Type 3I: Deck Description: System Type A(3): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved EPS Minimum 1.5" thick N/A N/A Note: Insulation shall be adhered with Soprema High Velocity Insulation Adhesive III (HVIA-III), High Velocity Insulation Adhesive III Green or High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation adhesive applied in continuous 3/4" wide ribbons at a maximum spacing of 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. ••.. ••IIiveSheet:. • • • • . •Priltter: •• • ••••1• PJy Sheet: •'• • •. •1.1 •Mentrane!....• • • • • • •• •• • • • 1.111. • . 11• Maximum Design Pressure: 1.111. • • .. 11 ••.••• • • • • • • • •• • •• •• MIAMFDADE COUNTY APPROVED One layer of Sopralene Stick or Colphene Stick, self -adhered. Base sheet primed with Elastocol Stick or Elastocol Stick Zero. None Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Sopralene 180 Ultra FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 250 FR GR, Sopralene 250 Ultra FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive at 1.5 — 2.0 gallons / square to sand surfaced ply membrane -75 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 26 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(4): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, ENRGY 3, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Sopraboard Minimum 1/8" thick N/A N/A Note: All insulation shall be adhered to the deck with full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or 0.75" wide beads of Insta-Stik Quik Set Insulation Adhesive, OlyBond 500, TITESET Roofing Adhesive, 3M Polyurethane Foam .... • Insulation Adhesive CR -20, Millennium One Step Foamable Adhesive, Millennium One Step • • • • • Green Foamable Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive, II4h Velocitp'• •• Insulation Adhesive III (HVIA-III), High Velocity Insulation Adhesive III — Greeq,�11 ' Velocrity •• Insulation Adhesive PG, Duotack or Duotack Neo spaced maximum 12" o.c. or Perautic applied' at a rate of 1.5 gal./sq. Please refer to Roofing Application Standard RAS 117 for iguintion : •. • attachment. Insulations listed as base layer only shall be used only as base layers'witkaiseconci layer of approved top layer insulation installed as the final membrane substrate. • • • • Base Sheet: One layer of Elastophene Sanded, Colphene Sanded, Elastophene S'aMed 2.2, • Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, lastophene 1'.S*�.: • Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Siled•Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 Sopralericb 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, • adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied ply membrane. Ply Sheet: One or two layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 27 of 160 ...... • • • OOOOOO . • •..... • • ••... • ..... ...... • • • ...... • • ...... Ply Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene (Optional) Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene (Continued) PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to three plies of Sopra IV or Sopra VI ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. to sand surfaced base membrane *Requires torch -applied cap membrane. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 "". •▪ FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV •••••• ▪ "• • • Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT • . •• •• • •• •• •• • • • • • • . range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY " ..:... Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. to sand • • • ...... •••• surfaced base or ply membrane •• • • • •' Surfacing:...... Surfacing is Optional on granular surfaced field cap membranes. • • • •"" • ••.. Surfacing is Required for smooth or sanded surfaced field cap membranes. •• "' Refer to Underwriters Laboratories or Intertek Testing Services listings for • . •• • • •• • •• applicable fire classifications. ...... •• .• . . Apply any coating listed in Table 4 above, or any Miami -Dade approved coating • ▪ • ▪ "" • • • • • • • • • system M• aximum Design Pressure: -105 psf. (See General Limitation #9) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 28 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(5): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ISO 95+GL, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck with full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or 0.75" wide beads of Insta-Stik Quik Set Insulation Adhesive, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive, High Velocity •••• • Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesive III — Green !Ugh Velocity • • Insulation Adhesive PG, Duotack or Duotack Neo spaced maximum 12" o.c. Pleasj•5,fa to :•„ •• Roofing Application Standard RAS 117 for insulation attachment. Insulations lisV41.4%Mase layer • only shall be used only as base layers with a second layer of approved top layer insulation instnea. as the final membrane substrate. •• •.. • • • • • .. Base Sheet: One layer of Elastophene Sanded, Colphene Sanded, Elastophhfl$ded 2.2, • Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62'$lestophenePSI?: Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180Egaridred, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS', Sopcaleat. 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopfalcfle 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and: at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied ply membrane. Ply Sheet: One or two layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 29 of 160 •••••. • • • ••.•.. • . ••.... ••.•. . • •.••• ••••.. • • • ••••.. • • ••..•. • • Ply Sheet: (Optional) (Continued) Membrane: ..... '•..• •• . ••• • • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 • • • •• •• •• •• ••"' FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV ...... • • Alu Sanded adhered in a full mopping of approved asphalt applied within the "• EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY •• . •• •• • q • Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. to sand • •..•.• ..... • • • surfaced base or ply membrane. •• •• ...... ...... Surfacing: • • • Surfacing is Optional on granular surfaced field cap membranes. . • ...... . • . . . Surfacing is Required for smooth or sanded surfaced field cap membranes. • • • . • • • Refer to Underwriters Laboratories or Intertek Testing Services listings for Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to three plies of Sopra IV or Sopra VI ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. to sand surfaced base membrane *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ • • GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene •• • • • applicable fire classifications. • • Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -105 psf. (See General Limitation #9) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 30 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(6): One or more layers of insulation adhered with approved adhesive or asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Minimum '/" thick N/A N/A Approved High Density Wood Fiberboard Minimum 'A" thick N/A N/A Sopraboard Minimum 1/8" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of insulation. All insulation shall be adhered to the primed deck in full moppings of. '••. approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 oringb'VClocity® • Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesive III — Green ligh Vetoer • Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable tltesive, • Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscol,itf ti ulatioi• Adhesive applied in continuous 3/4" to 1" wide ribbons at a maximum spacing of 12"8.t. Please •.• refer to Roofing Application Standard RAS 117 for insulation attachment. InsulafioMisted • base layer only shall be used only as base layers with a second layer of approved ;whirr • • • • insulation installed as the final membrane substrate. Composite insulation panels m•ay:be used a%•� a top layer placed with the polyisocyanurate side facing down. • • •.... • Base Sheet: One or more layers of Sopra G, Modified Sopra G, Sopra-IV, SoMa-Vi, Soprabese,. (Optional) Soprabase S adhered in a full mopping of approved asphalt applied within the EVP range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied (not permitted as first layer on wood fiber) Or One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Type IV or Type VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. *Requires torch -applied cap membrane. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 31 of 160 ...... .• . OOOOOO• • ..•... . • •.... .OOOOO. OOOOOO . . OOOOO. • • ...... • • 000000 • • • •••••• • • •••••• • • ••••• • • ••••. ••.•S• • • • • • •••••• • • Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced ply membrane. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. .1VI zimum Dgsign. -105 psf. (using High Density Wood Fiberboard) (See General Limitation #9.) Fres re: ' .. -127.5 psf. (using DensDeck or Sopraboard) (See General Limitation #9.) • • • • •• ••••4• • • ...1 • • • • • •• • ... • • • • 1 • • •• • • • • •• .. •• •• • ••• 0000 • • • • • • • •• • • • • MIAMI•DADE C f APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 32 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(7): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, Sopra-ISO r, M -Shield, H -Shield Minimum 1.4" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Minimum %" thick N/A N/A Approved High Density Wood Fiberboard Minimum %" thick N/A N/A Sopraboard ••.. Minimum 1/8" thick N/A • . N/A• • Note: All insulation shall be adhered to the deck with High Velocity® Insulation AcftiesisTe III :•. •. .' (HVIA-III), High Velocity® Insulation Adhesive III — Green, High Velocity Insulatipi•Aahesiv? • • •••••• PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium.Q,pg Step .. •••••• • Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive•alted • in • .: continuous 3/4" wide ribbons at a maximum spacing of 12" o.c. Please refer to Rad"�••••••••••••••••••• .• Standard RAS 117 for insulation attachment. .• • • Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at gyrate of 1 gal./sq' • (Optional) to top surface of any insulation, base or ply sheet prior to appliaatiogof next leydx. • • ••. • Base Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Soprabase s, Elastoph&tte • •: •""• (Optional) Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, • • Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallon / square. *Requires torch -applied ply membrane. •.••.• MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 33 of 160 Ply Sheet: Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. (not permitted as first layer on wood fiberboard) Or Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch - applied (not permitted if base membrane is used) (not permitted as first layer on wood fiberboard) Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded*, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallon / square. *Requires torch -applied cap membrane. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene .... Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR •"" • 0000.. � • • •• • GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam •• • • • • . ,•,•,. 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, •• • • "' . • • •• • • • Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • • 0000•• . •• •••• • • • • • Or .. . •0006 • • •'• •• • • Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ ••••• • . • • ••• •. •••••• 4140 • • • • • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 • • • • • • • • • • • • • . • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu • ..• Sanded adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 00 • • • •' gallon / square to sand surfaced ply membrane. • Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design -105 psf. (using High Density Wood Fiberboard) (See General Limitation #9.) Pressure: -127.5 psf. (using DensDeck or Sopraboard) (See General Limitation #9.) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 34 of 160 Membrane Type: SBS Deck Type 3L• Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(8): One or more layers of insulation adhered with approved adhesive or asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-H, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Top Insulation Layer DensDeck Minimum '/" thick N/A N/A Approved High Density Wood Fiberboard (requires two coat application of OlyBond) Minimum 'A" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prig; Lq application of insulation. All insulation shall be adhered to the primed deck ilt fuUsmoppings of • approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100•ft2 tir O14142nd. Insulation Adhesive applied at a rate of 1 gal./100 ft2. Please refer to Roost •Applitatien Standard RAS 117 for insulation attachment. Insulations listed as base layer orT hall be usSd only as base layers with a second layer of approved top layer insulation instgug4 as thi •fini<l, membrane substrate. Composite insulation panels may be used as a top Iays;algged with tis: polyisocyanurate side facing down. •. •• •• • •. . •. ...•. Base Sheet: One or more layers of Sopra G, Modified Sopra G, Sopra-IV, Sopra�VI, • (Optional) Soprabase, Soprabase S adhered in a full mopping of approved aspjialt ap jiod :. within the EVT range and at a rate of 20-40 lbs./sq.• • •' . • • • • Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied (not permitted as first layer on wood fiberboard) Or One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Type IV or Type VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. *Requires torch -applied cap membrane. Insulation Fasteners Fastener (Table 3) Density/ft2 MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 35 of 160 ...... . . . OOOOOO ••••S. • • ..... • • OOOOO ...... • • • ...... ...... • • 000000 Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene FR GR, Elastophene FR+ GR, Elastophene LS FR GR, Elastophene GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced ply membrane. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. At iimum Design -105 psf. (using High Density Wood Fiberboard) (See General Limitation #9.) • • Anecsure: • • ; -232.5 psf. (using DensDeck) (See General Limitation #9.) • . .• . •• • • • • •.•••• 000• 000 • •.•••• ••••.• • •• •Y.• • •00000 • • • • • .• • •••• • • • • •.•••• •.••••• • • • • •• •• ••••.• •• •• • •..••• • • •• • •o • 000 • • • • • 000000 • • • • • •••••• • ••• • •. • • • • MIAMEDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 36 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(9): One or more layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ENRGY 3, H -Shield, M -Shield, Sopra-ISO r Minimum 1.4" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Minimum 1/4" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of insulation. All insulation shall be adhered to the primed deck in full moppings of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or High Velocity® Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive applied in continuous %" to 1" wide ribbons at a maximum spacing•of 12" o.c. •tfeaie refer to Roofing Application Standard RAS 117 for insulation attachment. Itipptattons lifted ps •• base layer only shall be used only as base layers with a second layer of a,pprAyyd top layer • • insulation installed as the final membrane substrate. Composite insulation panels :nay be used as • • a top layer placed with the polyisocyanurate side facing down. •••• • • • • • •• •• • • •••• •• •• Base Sheet: One layer of Elastophene Sanded, Colphene Sanded, Elastophepe &piled 2.2,. • • Membrane: MIAMIDADE COUNTY APPROVED Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, >31att4hene P$l•1, •. Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, SoptaJ ,.Elastophene • • PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180•PS*, 9oprale• i$Q • PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250.3anded adhered in full mopping of approved asphalt applied within the EVT range and at a rage of •• 20-40 lbs./sq. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. (Maximum Design Pressure -120 psf, See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 37 of 160 . Membrane: (Continued) Surfacing: Or Elastophene FR GR, Elastophene FR+ GR, Elastophene LS FR GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. (Maximum Design Pressure -112.5 pst, See General Limitation #9.) Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: See Membrane Options Above. • .. . .. . • • . • • • . • • .. . • .. .... .. . . .. • .... • . • • . .... .. .. . . . • • • . . . • ... . . • . . • .. MIAMFQADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 38 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(10): All General and System Vapor Barrier MIAMEDADE COUNTY APPROVED SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto concrete deck. Limitations apply. One or two layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded fully adhered in COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 gal/sq. over concrete deck primed with asphaltic primer at 0.75 gal/sq. (Meets Maximum Design Pressure of —120 psf. See General Limitation #9) Or One layer of Sopravap'r, self -adhered to concrete deck primed with Elastocol Stick Zero at 0.5 gal/sq. (Meets Maximum Design Pressure of —240 psf. See General Limitation #9) Or One or two layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded of • • • . Sopralene 250 Sanded fully adhered in COLPLY EF Adhesi;eapp4ied at arae. of 1.5 gal/sq. . . . •• •• (Meets Maximum Design Pressure of —270 psf. See General.l,tratation #9), Or ••••• •• • • •• • • •••. . .. One or two layers of Elastophene Sanded, Colphene Sanded; E astephen . • Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastepher 180 Sanded Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralen$ !SC! Sanded, • Sopralene 250 Sanded or two or more layers of Sopra G, Mddified•Soprar • :. Sopra-IV, Sopra-VI, Soprabase adhered in hot asphalt at 25 ;b i./5q: over ... • concrete deck primed with asphaltic primer at 0.75 gal/sq. (Meets Maximum Design Pressure of 27O psf. S� General Limitation #9) Or •. One or two layers of Elastophene Stick, Sopralene Stick, Colphene Stick, self - adhered to concrete deck primed with Elastocol Stick or Elastocol Stick Zero at 0.5 gal/sq. (Meets Maximum Design Pressure of —315 psf. See General Limitation #9) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 39 of 160 One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, M -Shield, Sopra-ISO r, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, H -Shield CG, Sopra-ISO+ r, M -Shield CG, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard Polyiso Insulation Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A Note: All insulation shall be adhered to the vapor barrier in Duotack or Duotack Neo in %z" to %" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as a final membrane substrate. Base Sheet: • . . . . . .. . .. • . .. . • • • . . • .. .... • . . . .. • .... • • • • . .. .. . . .. .. • • ... • • .. . . .. • • .. MIAMI DADE COUNTY APPROVED One or two plies of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive or COLPLY EF Adhesive at 1.5 — 2.0 gallons / square. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Elastophene Flam HS*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied ply or cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 40 of 160 Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Membrane: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene FIanZ25Q Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, •••••• Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antiroele; torch-appked . . Or • Elastophene GR, Elastophene FR GR, Elastophene LS FR GJ ,'L'Pastophea8. '. FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colpheneib'FR GR' " . • Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopra1e a 250 FRG i.•. i. Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 21,Q pm. FR GR, • • • Sopralast 50 TV Alu Sanded adhered in a full mopping of aliproVea asphalt . • applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY>*T' • . Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at i.5 — 20 • : • • gallons / square. to sand surfaced membrane. • • Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. • •• • •• See Vapor Barrier Options Above. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 41 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(11): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r, ENRGY 3, Ultra -Max Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck with 0.75" wide beads of High Velocity® Insulation III (HVIA-III), High Velocity® Insulation Adhesive HI — Green, High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive spaced maximum 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a %stmt layer of approved top layer insulation installed as the final membrane substrate. Base §heet: •.• •• : One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded • (Outio• ral) 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, . •.. .... Sopralene 180 Sanded, Sopralene 250 Sanded, fully adhered in COLPLY EF •• ' • • • • . Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallon / • •' • • • • •• •• PlySheet: (Qptioaal) • square. • •• .. • . • • • • •• . . • • •.. • .• • • Membrane: MIAMI-DADE COUNTY APPROVED (Required if no Base Sheet used) One or more layers Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Sopralene 180 Sanded, Sopralene 250 Sanded, fully adhered in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallon / square. Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded fully adhered in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallon / square. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 42 of 160 Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system Maximum Design Pressure: -135 psf. (See General Limitation #9) MIAMI-DADE COUNTY APPROVED .. . . . .... . . .• .. . .. . • • • .. • • • • . . . ... • • • • • • • .... • .. • • • • • • • .. .. .. .. • • . • • . . • • .. • • • .. • ... • 00 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 43 of 160 Membrane Type: SBS Deck Type 31: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(12): One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto primed concrete deck. All General and System Limitations apply. Prinier: Concrete deck shall be primed with ASTM D-41 primer. Vapor Barrier: One or two layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded fully adhered in COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 gal/sq. over concrete deck primed with asphaltic primer at 0.75 gal/sq. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ENRGY 3, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Note: Insulation shall be adhered with High Velocity Insulation Adhesive III (HVIA-III), High Velocity Insulation Adhesive III Green or High Velocity Insulation Adhesive PG, Duotack, Iidota¢k Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable • A• wl�il ive or•leenium PG -1 Low Viscosity Insulation adhesive applied in continuous '/z" wide •• rilbboIts at a•ntijupum spacing of 12" o.c. Please refer to Roofing Application Standard RAS 117 • • • • • fot insulation, athment. Insulations listed as base Layer only shall be used only as base layers with Asecond•layer of approved top layer insulation installed as the final membrane substrate. • • • • • Prtmef: •••• • • • • • • • ••• ••• •• •• Base Layer: • • • • Agemix-ane: • • • ••• •• Surfacing: • • • • •• Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of next layer. One layer of Sopralene Flam Stick, self -adhered. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -150 psf.; (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 44 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(13): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, (Optional) Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched applied to ASTM D 41 primed concrete deck. One or more layers of any of the following insulations. Base Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, M -Shield, Sopra-ISO r, ACFoam-II, Sopra-ISO s, ISO 95+ GL, Multi -Max FA -3, Sopra-ISO x, ENRGY 3 Minimum 1.5" thick N/A N/A Top Insulation Layer DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum '/4" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A Note: All insulation shall be adhered to the vapor barrier or deck in Duotack or Duotack Neo applied in continuous i/2" wide ribbons maximum spacing of 12" o.c. Please refer to Roofing•.... • Application Standard RAS 117 for insulation attachment. Insulation listed as base ler only shaH be used only as base layers with a second layer of approved top layer insulation Walled as *to • final membrane substrate. • • Base Sheet: • • . • Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2s ala .tophea . • • Sanded 3.0, Elastophene PS*, Elastophene PS 3.0*, Elastophene kW*, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopraretirrir Sanded . : 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopfalerfer 180 PS 2.2'1' . Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanedeciadiered in ' '. COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY V Adhesive pa..' rate of 1.5 gal./sq. or adhered in hot asphalt at 25 lbs./sq. • .. • : • • • • Or •• Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Elastophene Flam HS*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 45 of 160 Membrane: Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 Ultra FR GR, Sopralene 180 FR+ GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 Ultra FR GR, Sopralene 250 FR+ GR, Soprastar Sanded, Sopralast 50 TV Alu Sanded adhered in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at a rate of 1.5 gal./sq. or adhered in hot asphalt at 25 lbs./sq. Or Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design -150 psf. with DensDeck Prime (See General Limitation #9.) Pressure: -337.5 psf. with SECUROCK (See General Limitation #9.) ...• . • •• .. • .• .. • • • • .• ••• . • •• • • ..• •••• • • • • .. .. • • .. .. • • • • • • • • • .. • • • ••• • .. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 46 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(14): Substrate Preparation: Primer: Vapor Barrier (Optional): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Substrate primed with approved ASTM D41 primer One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene 250 SP, torch -applied. Or One layer of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Any approved EPS Minimum 1.5" thick Top Insulation Layer Sopraboard Minimum 1/4" thick N/A Insulation Fasteners Fastener (Table 3) Densifsyi'fti. • . .. . .a . N/A N7A•••• • Insulation Fasteners Fastener (Table 3) • • Dens:Witt. • • . . .. . • Ni4►• .•. Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allovted to pry prjor tQ application of vapor barrier or insulation. All insulation shall be adhered to the vapor barrtPtfr • primed deck in full mopping of approved hot asphalt within the EVT range and'ati rite of 20,40 lbs./10ft2 or High Velocity Insulation Adhesive -III (HVIA III), High Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive -PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive in 3/4" ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) MIAMIDADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of next layer NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 47 of 160 .• • • • • • • • • ••a• ,. • . Base Sheet: One layer of Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, • • • • •• • Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot .... .'. asphalt at 25 lbs./sq. to sand surfaced base membrane. • • .• • •• • •• • •• *Requires torch -applied cap membrane. • • • • Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, • • • • •• •• •• • • • • Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene •• • • • • •••• Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene • • • • ' • • • ` Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR • • " " `• GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam • . 4 • • •• • 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, • • • Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. •'•. •••• Or • • • • • •' Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply membrane. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: MIAMIOADE COUNTY APPROVED -152.5 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 48 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(15): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved EPS Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A SECUROCK Gypsum -Fiber Roof Board Minimum 1/4" thick N/A N/A Note: All insulation shall be adhered to the deck with High Velocity® Insulation Adhesive -III (HVIA-III), High Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive - PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive applied ip••••. continuous'/:" —3/1" wide ribbons at a maximum spacing of 12" o.c. Please referto Aoufing• •.•• • Application Standard RAS 117 for insulation attachment. • • •• • • • • •• Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied atarok of 1 gal./sq., • • (Optional) to top surface of base or ply sheet prior to application of next 1a'.*. • • • • •• ••• •• Base Sheet: One layer of Colvent SA, Sopralene Stick, Colphene Stick, Els •4�ljejie Flab • • • • • • • • • MIAMI-DADE COUNTY APPROVED Stick* or Sopralene Flam Stick*, self -adhered. Or • One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene F1annHS*: Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Cotohept.SP 3.00, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3' .1!), Sbpraleti21$0; SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*,6 Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied ply or cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 49 of 160 • • • • Ply Sheet: Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene (Optional) SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Membrane: Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or •••• a ••••• • • Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ • • • • • • • • GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene •• •• • • • • • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 • • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu • ••' • • . . . . •• Sanded adhered in hot asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY • • Modified Adhesive at 1.5 — 2.0 gallons / square. to sand surfaced ply membrane. • Sit ilting: • • • • Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. • • • • •• • • • • • • • • • • • • • • • • • ... • •• Maximum Design Pressure: -152.5 psf. (See General Limitation #9.) MIAMHDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 50 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(16): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to deck. Vapor Retarder: Colvent SA, self -adhered. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ACFoam-III, Sopra-ISO+ s, EnergyGuard Polyiso Insulation, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield, H -Shield CG, Sopra-ISO r, Sopra-ISO+ r, ISO 95+ GL, ENRGY 3, Multi -Max FA -3, Sopra-ISO x, M -Shield Minimum 1.5" thick N/A Top Insulation Layer (Optional) Sopraboard Minimum 1/8" thick SECUROCK Gypsum -Fiber Roof Board Minimum'/" thick N/A Insulation Fasteners Fastener (Table 3) N/A N/A Density/ft2 • • • •• • • •••• NIA ••• • •• • • • • •• N/A • •••• •• • Note: All insulations shall be adhered with High Velocity Insulation Adhesiiii (HVI�i-$�j,' h High Velocity Insulation Adhesive III Green or High Velocity Insulation Adheiwe•PG, Duptac,J„ Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step' Giten Foanfdblt' Adhesive or Millennium PG -1 Low Viscosity Insulation adhesive applied in copti'iQAOis %" wide ribbons at a maximum spacing of 12" o.c. Please refer to Roofing Application Standard R4111 • for insulation attachment. Insulations listed as base layer only shall be used oily as base ;pars • with a second layer of approved top layer insulation installed as the final membrane substrate. • •: Primer: ASTM D41, Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to the base sheet. One layer of Colvent SA, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered. *Requires torch -applied ply or cap. Base Sheet: MIAMIDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 51 of 160 Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Sopralene 180 Ultra FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 250 FR GR, Sopralene 250 Ultra FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded, adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY Adhesive, COLPLY Modified Adhesive at a rate of 1.5 gal./sq. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. 1 a'aimum Design PfesSere:• • • . -155 psf.; (See General Limitation #9.)• . .. . .. . .• . . • . . • • • . .. . • •• •• • • ••• • • • • • • •• •• •• • • • ••• •••• • • •••• • • •• •• • • . • • • • • •• •• MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 52 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(17): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ACFoam-III, Sopra-ISO+ s, EnergyGuard Polyiso Insulation, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield CG, Sopra-ISO+ r, Multi -Max FA -3, Sopra-ISO x, H -Shield, Sopra-ISO r, M -Shield, ENRGY 3 Minimum 2" thick N/A N/A ISO 95+ GL (Only with Hot Asphalt, Insta-Stik or HVIA Adhesives) Minimum 2" thick Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Sopraboard ' ' ••••• .•.... Minimum 1/8" thick N/A • • • N/A • Note: All insulations shall be adhered to the deck with full mopping of approved'118C Mphalt' '' within the EVT range and at a rate of 20-40 lbs./100 ft2 or Insta-Stik Quik Set Ins'dl'alion Adhesives OlyBond 500, TITESET Roofing Adhesive, 3M Polyurethane Foam Insulation Adhesrve CR10 br• • Millennium One Step Foamable Adhesive or High Velocity Insulation Adhesive I11 j> vIA-IIIA High Velocity Insulation Adhesive III (HVIA-III), High Velocity Insulation Adhe§Ve.111 Green or•: High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step.1 oamable • Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 tow Viscosity • Insulation adhesive applied in continuous'/" wide ribbons at a maximum spacing of j2; o.c. ' Please refer to Roofing Application Standard RAS 117 for insulation attachment. ¶Asulations "• listed as base layer only shall be used only as base layers with a second layer of approved top layer• insulation installed as the final membrane substrate. Primer: ASTM D41 or Elastocol 500 applied at 0.75 gal./sq. or Elastocol Stick or (Optional) Elastocol Stick Zero at 1.0 gal./sq. Base Sheet: One layer of Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* or Colvent SA, self -adhered. *Requires torch -applied ply or cap. MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 53 of 160 • • • • • • • • • • • • • • • . • . • Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Sopralene 180 Ultra FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 250 FR GR, Sopralene 250 Ultra FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded, adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY Adhesive, COLPLY Modified Adhesive at a rate of 1.5 gal./sq. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. 4Vlaitmum Design Pressure: .'. -172.5 psf. (See General Limitation #9) • .. • .. •. . •• • .. • • • ..• • • • • .. .. . • • • • ••• • .. • • •••• • . .. .. • • . • • • • • • .. MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 54 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(18): SBS Concrete Decks, Insulated Min. 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: . One or two plies of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched applied to ASTM D 41 primed concrete deck. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners (Table 3) ACFoam-II, ACFoam-III; Sopra-ISO s, Sopra-ISO+ s, H -Shield, M -Shield, Sopra-ISO r, ENRGY 3, ISO 95+ GL, Multi -Max FA -3, Sopra-ISO x (flat or tapered) Minimum 1.5" thick N/A Fastener Density/ft2 N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board, DensDeck, DensDeck Prime Minimum 0.25" thick N/A N.A' • % • . . ..•• . • •• . Note: All insulation shall be adhered in High Velocity® Insulation Adhesive III (g'o--III), gig%. • Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive PGi,JOgtack, • Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step GreeiFoamable • Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive or OlyBond 500 appli.J in 1/2'& to • • • '/" wide ribbons spaced 3" o.c. Please refer to Roofing Application Standard RA$ t iT dor . • . insulation attachment. Insulation listed as base layer only shall be used only as base flyers with'a' • second layer of approved top layer insulation installed as the final membrane sulttflte: • • • • Colvent Flam TG, Colvent Flam 180 TG, Elastophene Flam, Elastophene Flim 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2 2,ClastopheM►8 sp 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 ' • SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torched -applied. Base Sheet: Ply Sheet (Optional): Membrane: MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 55 of 160 Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -187.5 psf. (See General Limitation #9.) .. . • . .. .• .. . . . . . . . . .. . . • .. • • • ..• • • • • .. .. • • • ••• . • • •••• • • • • • • • • • • • • • .. MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 56 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(19) One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ENRGY 3, H -Shield, Sopra-ISO r, M -Shield or Multi -Max FA3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 DensDeck Minimum 0.25" thick N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. Refer to Roofing Applic L,pji Standard RAS 117 for insulation attachment. Insulations listed as base layer only Shall bt.gjt only as base layers with a second layer of approved top layer insulation instgljed:as thenal membrane substrate. : ' • •' Base Sheet: Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flat►t*,•3dpralene ' Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastopb8dM SP 2.2, :' • • Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralen 1$b SP 3.0, . • • Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SPz %• applies • . *Requires torch -applied Ply or Cap. • •, Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sangad& • : • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded./.€, Col1211ene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastoptene PS*, •.; Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS*, applied in hot asphalt at 25 lbs./sq. Ply Sheet: (Optional) MIAM WADE COUNTY APPROVED • • • or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 57 of 160 • • Membrane: Surfacing: Maximum Design Pressure: •••• • . •••• • • • • • . • • .• •• ••• • • • •• • • • • • • •' • •• •• • • •• • • • • • •• •• • • .•• • • •••• • • •• •• • • • • • • • • • • • • • • ••. •• •• MIAMI-DADE COUNTY APPROVED Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -187.5 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 58 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(20): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ACFoam III, Sopra-ISO+ s, EnergyGuard POLYISO Insulation, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield, Sopra-ISO r, M -Shield, H -Shield CG, Sopra-ISO+ r, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Minimum 0.25" thick N/A N/A Note: All insulations shall be adhered with Duotack or Duotack Neo applied in continuous ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a woad layer of approved top layer insulation installed as the final membrane substrate... •••• • • Base Sheet: Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Fla no•, Sdpralenrhlarm 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene RP 2;t,tolphene F3 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0,'Soplaiene l80 SPS 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. • • • *Requires torch -applied Ply or Cap. •-. • • • Elastophene HS 62, Elastophene Sanded, Colphene Sanded, E1asfdphthe Sanded..• • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Saru1e8;f 2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, . Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or.SCipthlene 120 • PS*, applied in hot asphalt at 25 lbs./sq.' • • Ply Sheet: (Optional) MIAMI-DADE COUNTY APPROVED • • or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 59 of 160 Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: _187.5 psf. (See General Limitation #9.) • . •••• • • • • • • • • • • • • • • • • • • • • • • .•••• • • • • • • •• • • • •• • • • •• • • • • • • •• •• • •••• • • •••• • • ' • • • • • •• •• • • • • • • • • • ••• • • • • • • •• MIAMFOADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 60 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(21): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer - Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, EnergyGuard POLYISO Insulation, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield, Sopra-ISO r, M -Shield, H -Shield CG, Sopra-ISO+ r, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer DensDeck Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with High Velocity® Insulation Adhesive III (HVIA-II1), High Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive.•BCa Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive•er Millennium PG -1 Low Viscosity Insulation Adhesive applied in continuous riot of s mati1qut►L spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insu4ati*A•attacltme1it. Insulations listed as base layer only shall be used only as base layers with V Seednd layer' �f approved top layer insulation installed as the final membrane substrate. . : • • Base Sheet: Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flat;,•$agralene Ti tam• 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SEx2,.tolphene•gP • 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, & a1tne 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. • • Ply Sheet: (Optional) MIAMFDADE COUNTY APPROVED • • . • • . • • • • '• *Requires torch -applied Plyor Cap. • •• . ••• ••• . Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded • • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS*, applied in hot asphalt at 25 lbs./sq. or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 61 of 160 Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: Maximum Design Pressure: or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam -180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. •... • • •.•• • • ' •• • • • • •. • • •. • • • • • • • • • • • • • •• • • • •• • • • •• • • • • • •• •• • • .•. • • •••• • • •• •• •• • • • • • • • • • ••• • • •• • • • •• MIAMI.DADE COUNTY APPROVED -187.5 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 62 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(22): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: One or more plies of Sopra G, Modified Sopra G, Sopra IV, Sopra VI, (Optional) Soprabase, Soprabase S adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square to deck primed with ASTM D41 primer. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, Sopra-ISO r, M -Shield Minimum 1.4" thick N/A N/A Note: All insulation shall be adhered to the deck with full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or High Velocity Insulation Adhesive III (HVIA- III), High Velocity Insulation Adhesive III — Green or High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation adhesive applied in continuous 3/" wide ribbons at a maximum spacing of 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. •••• Primer: Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface Ave. (Optional) or ply sheet prior to application of next layer. • Base Sheet: One layer of Sopralene Flam Stick, self -adhered. .... .. • . Ply Sheet: One or more layers of Elastophene Flam, Elastophene Flam • • • (Optional) Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene S§P B4Q,0Colphelv• SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 1$Qj.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafl Basa622, • • Sopralene Flam 250, Sopralene 250 SP, Colvent Flam TG, Colvent41am 11k0 iG, torch -applied. Membrane: Surfacing: Maximum Design Pressure: MIAMFDADE COUNTY APPROVED • .. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -187.5 psf.; With vapor barrier (See General Limitation #9) -225 psf.; Without vapor barrier (See General Limitation #9) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 63 of 160 Membrane Type: SBS Deck Type 3I: Concrete, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(23): One or more layers of insulation adhered with approved adhesive or asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved EPS Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Prime Minimum 1/2" thick N/A N/A Note: All insulation shall be adhered to the primed deck in full moppings of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or High Velocity® Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step q.eep'Foamable Adhesive or Millennium PG -1 Low Viscosity Insulation Adhesive applied in • • cpnti,p.uous ""tQ 1i°' wide ribbons at a maximum spacing of 12" o.c. Please refer to Roofing •Apl3li4ation Ataudard RAS 117 for insulation attachment. Insulations listed as base layer only • • shall be used ally as base layers with a second layer of approved top layer insulation installed as • • .the fn al membNane substrate. Composite insulation panels may be used as a top layer placed with • . ti►1' polyisocyaenrate side facing down. • • • • • • • • • • 1as'4/ Ply Shlset: • • • • • • ••• • • • • • • • • • • • • • .• MIAMFDADE COUNTY APPROVED One layer of Elastophene Flam 3.0*, Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Elastophene Flam HS*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene PS*, Elastophene PS 3.0*, Elastophene HS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded adhered in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at a rate of 1.5 gal./sq. or adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied Cap sheet. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 64 of 160 Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Soprastar Flam, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied with minimum 3" wide lap. Or Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 Ultra FR GR, Sopralene 180 FR+ GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 Ultra FR GR, Sopralene 250 FR+ GR, Soprastar Sanded adhered in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at a rate of 1.5 gal./sq. or adhered in hot asphalt at 25 lbs./sq. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -195 psf. (See General Limitation #9.) MIAMFDADE COUNTY APPROVED .... • . •.... • • ▪ • • .. • .• • • • . . • • •• • . • • .... .. • • • • • • ...• . .. ▪ . . .. •• •• •• • •. . • • • • • • • . .. . ..• • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 65 of 160 • • •• Membrane Type: Deck Type 3I: Deck Description: System Type A(24): SBS Concrete Decks, Insulated Min. 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: Colvent TG or Colvent 180 TG, torched -applied. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ISO 95+ GL, Multi -Max FA -3, Sopra-ISO x, ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Prime Minimum 0.25" thick N/A N/A Nota. Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of• .aper barrier. All insulation shall be adhered to the vapor barrier in full moppings pf approved fiotgasphalt within the EVT range and at a rate of 20-25 lbs./100 ft2. Please refer to IY'd'ofizfg Aplflfc:lttdn Standard RAS 117 for insulation attachment. Insulation listed as base layer only hall be u'edanly as base layers with a second layer of approved top layer insulation installed esthe final memb/lane substrate. $ase'Sheet:. . .. .. .. .. Ply Sheet: : . 000 . . . •• 1,00. . .. . . • . 00 Membrane: Surfacing: Maximum Design Pressure: One layer of Sopra G adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-25 lbs./sq. Elastophene 180 PS, Colphene 180 PS, Sopralene 180 PS 2.2, Elastophene PS, Elastophene PS 3.0 adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. with minimum 3" wide side lap. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, torched -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -195 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 66 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(25): One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto concrete deck. All General and System Limitations apply. Vapor Barrier: MIAMI•DADE COUNTY APPROVED One layer of Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Sopralene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Soprastar Flam, Sopralast 50 TV Alu or Sopralene Flam Antirock torch -applied over an optional layer of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Elastophene Flam HS, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 250 SP, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5 or Colphene 180 SP 3.5, torch -applied over concrete deck primed with asphaltic primer at 0.75 gal/sq. Or One layer of Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene .180. FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GF, Sooralene 254 • • FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopra4ane 150 Ultra FRS GR, Sopralast 50 TV Alu Sanded adhered over an optional lam ;OAElastdphe' it Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastoplierfe•5dnded Elastophene HS, Elastophene HS 62, Elastophene PS, Elastophene PS 3.0=' • • Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 18b.ganded 2.24 • Elastophene 180 PS, Colphene 180 PS, Sopralene 180 PS, Sggrajsb a 180 P$.•.; 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded adhered ill . Adhesive, COLPLY Modified Adhesive or COLPLY EF Adtesive at 1.5.2.0 • .•.••• gal/sq. over unprimed concrete deck or adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsIsq. beer • • • concrete deck primed with asphaltic primer at 0.75 gal/sq. Or One layer of Elastophene Stick HR FR GR, Colphene HR FR GR, Elastophene Stick FR GR, Colphene FR GR or Soprastar Stick self -adhered over an optional layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick, Sopralene Flam Stick self -adhered to concrete deck primed with Elastocol Stick or Elastocol Stick Zero at 0.5 gal/sq. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 67 of 160 • One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, M -Shield, Sopra-ISO r, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, H -Shield CG, Sopra-ISO+ r, M -Shield CG, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard Polyiso Insulation Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A Note: All insulation shall be adhered to the vapor barrier in Duotack or Duotack Neo in' " to 3/4" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as a final membrane substrate. Base Sheet: One or two plies of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, • • • •' • Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene •••• • • 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded, adhered in a full . . • • • .. • . • • • • • 40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive or COLPLY • • • , • • • EF Adhesive at 1.5 — 2.0 gal/sq. •• • •• • • •• .... Or • • • • • • • • • • • One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam •• HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP • ▪ •• • • ▪ 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, • • • • • Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, • • • • • • • • • • Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. • • MIAMI- DE COUNTY APPROVED Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied ply or cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 68 of 160 Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at a rate of 1.5 — 2 gal./sq. Or • One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied cap membrane. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flan 480• • Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 11)0 I;R•GR 3.57•• • Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, SCOralene Flab$ 25D. Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 2W> R1- GR,' " Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antiroc)•C:torch-applied,, Or •• ..••• .. Surfacing: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR,TilaAtophen€.' .: FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene.1S9.tR GR, • Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralcne 250 FR q1L •: • Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 251) Ujtt4 FR OR, Sopralast 50 TV Alu Sanded adhered in a full mopping of apploved asphalt '. applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. To sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -195 psf. (See General Limitation #9.) MIAMIOADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 69 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(26): SBS Concrete Decks, Insulated Min. 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. Dry In Sheet: One layer of Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 20-25 lbs./sq. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A Top Insulation Layer Insulation Fasteners (Table 3) Sopraboard Minimum 1/8" thick N/A N/A Fastener Density/ft2 N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of dry in sheet. All insulation shall be adhered to the dry in sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed aSt1l final ntem4rane substrate. Composite insulation panels may be used as a top layer placed with the polyiSQeflurate side facing down. Bae Sheet: (bOptroial) • . . ..• .. • Pix .Wet: (Optidnal) .. Membrane: Surfacing: .... . . .. .. Maximum Design Pressure: One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. adhered in hot asphalt at 25 lbs./sq. (Required if no Base Sheet used) One or more layers Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system -210 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 70 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(27): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Retarder: Colvent SA self -adhered to primed concrete deck. (Optional) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners (Table 3) Approved EPS Minimum 1.5" thick Top Insulation Layer Sopraboard Minimum 1/8" thick N/A N/A Insulation Fasteners (Table 3) Fastener Density/ft2 N/A Fastener Density/ft2 N/A SECUROCK Gypsum -Fiber Roof Board, DensDeck, DEXcell Glass Mat Roof Board, DEXcell FA Glass Mat Roof Board Minimum 1/4" thick N/A N/A•....• DEXcell Cement Roof Board Minimum 7/16" thick N/A • N/A • • . . .. . •. . . • • . •S .... .. . Note: All insulations shall be adhered with Duotack or Duotack Neo applied in continuous rirbbmts maximum spacing of 6" o.c. Refer to Roofing Application Standard RAS 117 for fipgnlption . • . attachment. Insulations listed as base layer only shall be used only as base layersM itti'a second' layer of approved top layer insulation installed as the final membrane substrate.. . . Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at rate.Of 1 ga1i%tl•,•' (Optional) to top surface of base or ply sheet prior to application of next Itya' ; • • • . Base Sheet: MIAMI-DADE COUNTY APPROVED One layer of Colvent SA, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered over primed top insulation. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 71 of 160 • •• • • • • • • • • . • •••• • • • Base Sheet: (Continued) Or One layer of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied ply or cap membrane. Ply Sheet: Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene (Optional) SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot •••• asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 •• • • • • — 2.0 gallons / square. • • • • •• • • *Requires torch -applied cap membrane. • •• •• . •.• • • • Membrane: • Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam • 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, •• • ColpheneL'1,.«.. 'A CD !_D C•,.......1,..,,. L`1..«. ')G!1 Ultra CD !_D Sopralene Flam "'• • 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • • • • ••••• • • • .•• • ••••• • • • • • . ; • • • • •• •• •• • • • • • • • • • • •Or • •.. • .. •• Surfacing: Maximum Design Pressure: MANMADE COUNTY APPROVED Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. to sand surfaced ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -215 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 72 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(28): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer • Insulation Fasteners Fastener (Table 3) Density/ft2 ISO 95+GL, H -Shield, M -Shield, Sopra-ISO r Minimum 2" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck with full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or 0.75" wide beads of Pliodeck Insulation Adhesive, Insta-Stik Quik Set Insulation Adhesive, Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive, High Velocity Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesiyg.. III — Green, High Velocity Insulation Adhesive PG, Duotack or Duotack Neo spaced rgaximum.l,2'2 • o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment insulations• listed as base layer only shall be used only as base layers with a second layer of apprc�e I top Payer • insulation installed as the final membrane substrate. • Base Sheet: One or more layers of Elastophene Sanded, Colphene Sanded, Elasto ene 471,40 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS tophec . PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene VierSa'lded, •..•.: Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Cdplag 180 PS*,. Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 Pt*, Sopralene 2*50:• Sanded, adhered in hot asphalt at 25 lbs./sq. • . . . • . . . • . . . •• . •.• . • • *Requires torch -applied ply or cap membrane.• • • Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. MIAMPDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 73 of 160 Membrane: Surfacing: Maximum Design Pressure: .•... • • • • • • • • •• • •• • • • • • • • • • • • • •• •••• • • • • • •• •• •••• • • • • • • • • • • ••• ••• •• •• • • • •• • • • • • • • • • • • •• • • • • • ••• • • •• Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system -217.5 psf. (for insulation adhered with Pliodeck Insulation Adhesive) (See General Limitation #9) -225 psf. (for insulation adhered with all other adhesives) (See General Limitation #9) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 74 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(29): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, ENRGY 3, M -Shield, Sopra-ISO r Minimum 2" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck with full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2 or 0.75" wide beads of Insta-Stik Quik Set Insulation Adhesive, OlyBond 500, TITESET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR -20, Millennium One Step Foamable Adhesive, Millennium Ong Step •:::. • Green Foamable Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive, high Velocity, • Insulation Adhesive III (HVIA-IH), High Velocity® Insulation Adhesive III — Green,lIigh VelOcity. • Insulation Adhesive PG, Duotack or Duotack Neo spaced maximum 12" o.c. PIeate refer to . Roofing Application Standard RAS 117 for insulation attachment. Insulations listl<d%%base lever.. only shall be used only as base layers with a second layer of approved top layer insulitfion installed• as the final membrane substrate. • . • •Base Sheet: One or more layers of Elastophene Sanded, Colphene Sanded,131aotlghene Sande• 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, tlistophgne PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene; 80 S .nded, • • • • Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Cotphene 180 PS4', . Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 2U: Sanded, adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 75 of 160 •....• • • . •.•..• • • ••••.. • • ..•.• • •••.• •••••• .• OOOOO• • • .•••.• • • •...S. Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system Maxijnum Design • PrtSsure: •' • .• -225 psf. (See General Limitation #9) • • •• • •• • • • • • ' • •••S•• • SSSS.• •••• ••• SSSS SSSS•. • • •• •• .•..•• • • •.SS•• • • •SSSS SSSS• •..S.• •• • • • . • • • • • •.•S•• • • • . • • • • . • •• • • • • • • •• •• • SSSS•• • • •. • ..SSS• • • • • • • • •• • • • •• MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 76 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(30): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ENRGY 3, Multi -Max FA3, Sopra-ISO x, H -Shield, M -Shield, Sopra-ISO r Minimum 2" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. or Duotack or Duotack Neo applied in continuous ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be NW • • only as base layers with a second layer of approved top layer insulation installed as the final. membrane substrate. •••••• • '.. • • Base Sheet: Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*b$opralene Flarfl 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP'z.Z„ pAphae SP' • 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Saprsalene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. •••••• • Ply Sheet: (Optional) MIAMFDADE COUNTY APPROVED *Requires torch -applied Ply or Cap. • •' • • • • Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastpphege Sandal • •. • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 San3ed2.z, ColpJev e 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, •.; Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS*, applied in hot asphalt at 25 lbs./sq. or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 77 of 160 • • • • • •••••• • • ••••. • ••••• •••••• • • • •••••• • • •••••• • • Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: Maximum Design Pressure: •... • • ...1.• 1111 • • . • . .• • •. • • •.•.1. • •..... • • •..... • • .11•. ..11• •....• • • • .1.111 • • •...•• • • • • •• • • • .. • • • • • • •• •• •1•.1. • • •1• .1.111 • • • 1.11 ...•.. • • •• .• ••..S• • • • • • or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -225 psf. (See General Limitation #9.) • • • • • • 1• MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 78 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(31): One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-HI, Sopra-ISO s, Sopra-ISO+ s, H -Shield, M -Shield, Sopra-ISO r, ENRGY 3, ISO 95+ GL, Multi -Max FA -3, Sopra-ISO x (flat or tapered) Minimum 1.5" thick N/A N/A Top Insulation Layer Sopraboard Minimum 1/8" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A Note: All insulation shall be adhered in with hot asphalt at 25 lbs./sq. or in High Velocity® Insulation Adhesive III (HVIA-III), High Velocity® Insulation Adhesive III — Green, High Velocijy . Insulation Adhesive PG, Duotack, Duotack Neo, Millennium One Step Foamable f dhesive, •.... • Millennium One Step Green Foamable Adhesive, Millennium PG -1 Low Viscosity Insulation . • . Adhesive or OlyBond 500 applied in %" to 3/4" wide ribbons spaced 3" o.c. Pleasei$t4i'to Roofing • • Application Standard RAS 117 for insulation attachment. Insulation listed as base to of only shall be used only as base layers with a second layer of approved top layer insulation ins.... ta ed as the'. •. final membrane substrate. .• .. Base Sheet: MIAMI.DADE COUNTY APPROVED Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent F1aM 180 TG*, • • • • • Elastophene Flam*, Elastophene Flam 2.2*, Elastophene F1an}$lastophefie SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.Q, Sopralene Lang. 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene t $Q Sl; 3.5, • Colphene 180 SP 3.5, Sopralene Flam 250* or Sopralene 250 SP, torch -applied... Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS* Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene Sanded*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 79 of 160 OOOOOO • • • OOOOOO• • ••..•. .••• • • •..•• •S.••. .• • •••••• • • •••••. Ply Sheet Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene (Optional): SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. Membrane: Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS* Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene Sanded*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torched -applied. .... • ▪ Or ...... .... • • • • • Elastophene GR, Elastophene FRElastophene LS FRElastophene FR+ • • PPGR, PGR, P ...... • • • • GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene •... ▪ • •• • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 • • • •• • • • ' • ... • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV • •• •• • • Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply ...... .. • • • • membrane. • ...... • • SurfaSing: • • • Surfacing is Optional on granular surfaced field cap membranes. ...... ...... • • Surfacing is Required for smooth or sanded surfaced field cap membranes. • ...... . • • Refer to Underwriters Laboratories or Intertek Testing Services listings for • • . .•• applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -232.5 psf. (See General Limitation #9.) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 80 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(32): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Vapor Barrier: Primed with asphaltic primer at 0.75 gal/sq. One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 250 SP, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5 or Colphene 180 SP 3.5, torch -applied to a layer of Colvent Flam TG or Colvent Flam 180 TG, torched -applied. Or One layer of Colvent TG or Colvent 180 TG, torched -applied. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 H -Shield, M -Shield, Sopra-ISO r, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, H -Shield CG, Sopra-ISO+ r, M -Shield CG, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO-66•0. • ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard Polyiso Insulation •• . • . . Minimum 1.5" thick N/A " N/A ; • • • • •••... • Top Insulation Layer Insulation Fasteners • • • fastener • Sopraboard Minimum 1/8" thick (Table 3) . • • 5epsity/fP2• • • • •••• •• •. N/A • • •• "%1/A . ; •• •• .• .. Note: All insulation shall be adhered to the vapor barrier in Duotack or Duotac '1 5 n %2" to %" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS•117 fdr insubtipp• attachment. Insulation listed as base layer only shall be used only as base lay.is•w,th a second layer of approved top layer insulation installed as a final •membrane substrate. "'.• Base Sheet: .• One or two plies of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive or COLPLY EF Adhesive at 1.5 — 2.0 gal/sq. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 81 of 160 •••••• �• •.••.• ••••.• • • ••••• • • ••.•• •••••• • • • •.•... • • •••..• • • ...... • • •• . • • • •• •e • Base Sheet: (Continued) Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied ply or cap membrane. Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. 0000 •• •••• • • •....•• •• ...•• • • •• • • • Or ..... .. • ..•• • •• • • • • • One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene ..... •• ...... .. • • • • •• •• Stick*, Sopralene Flam Stick* self -adhered. • • *Requires torch -applied cap membrane. • • • • 4ItMlirane▪ :• • • Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, ...... •• • • • • Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, • • • • 4.. • • • Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 • Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • MIAMFDADE COUNTY APPROVED Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. To sand surfaced membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 82 of 160 Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -232.5 psf. (See General Limitation #9.) MIAMI•DADE COUNTY APPROVED ••4• •• • • • • •••, ••• • •• • • •• • • • • 4.44•• • 4444.• • •••••. • • • •• •• • •••••• •••••. 0400 • •• 0000. •••0••• • • • •• • • • ••••0 •• •• •0 •• OO •••••• • • •• • • • 4.••:• • • •••••• • . • • • • 4,041 4,041 • .. . • • •••••• • • • 00 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 83 of 160 000000 • • • ..•••• • • 000000 • • Membrane Type: Deck Type 3I: Deck Description: System Type A(33): SBS Concrete Decks, Insulated Min. 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: Colvent TG or Colvent 180 TG, torched -applied. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ENRGY 3, H -Shield, H -Shield CG, Sopra-ISO s, M -Shield, Sopra-ISO r, M -Shield CG, Sopra-ISO+ r Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 N/A SECUROCK Gyspum-Fiber Roof Board Minimum 1/4" thick N/A Sopraboard Minimum 1/8" thick N/A N/A • looter Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to §pptication:ofvojor barrier. All insulation shall be adhered to the vapor barrier in full moppings •q'dp:roved he asphalt within the EVT range and at a rate of 20-25 lbs./100 ft2. Please refer to Roofing Apphtlltilln Standard RAS 117 for insulation attachment. Insulation listed as base layer onl"•siall be mei, only as base layers with a second layer of approved top layer insulation installed • ••••• as•thefinal m'emnrane substrate. • •.•••• •.Sheet: • • • • • • One layer of Sopra G adhered in a full mopping of approved asphalt applied • •••••• • • within the EVT range and at a rate of 20-25 lbs./sq. • • • ••••• .1•••* • • • •••••• • • 000000 • • P1y fiiieet: • ••• • • •• Membrane: Surfacing: • • • • • • • •• •• Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED Elastophene 180 PS, Colphene 180 PS, Sopralene 180 PS 2.2, Elastophene PS, Elastophene PS 3.0, adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. with minimum 3" wide side lap. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torched -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -240 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 84 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(34): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, Sopra-ISO r, M -Shield, H -Shield Minimum 1.4" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A Note: All insulation shall be adhered to the deck with OlyBond Adhesive Fastener at 1 gallon/square. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied ata rat e of 1 ••••• gal./sq., topsurface of anyinsulation, base or plysheet rifr lication °: • (Optional) g q•� P � .tP•al� � • of next layer. • . . • .• •• Base Sheet: One layer of Sopra G, Modified Sopra G, Sopra IV, Sopra V)Wbase, • (Optional) Soprabase S, Elastophene Sanded, Colphene Sanded, Elastoptng Sanded: •.• ••. 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene I�$ b2 • Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sandal, Gblpheitt.. •• 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS!pColphene 180 . PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopraletie 180:PS*, . . Sopralene 250 Sanded, adhered in a full mopping of approvdcl aSy It apAred9.6 within the EVT range and at a rate of 20-40 lbs./sq. or in COI;PLY•Adhegiveb COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. • • *Requires torch -applied ply membrane. Ply Sheet: One or two layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or MIAMWADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 85 of 160 ...••. • . • ...... • • OOOOOO • • ..... • ..... ...... • • . •..... ...... • • Ply Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene (Continued) Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to three plies of Sopra IV or Sopra VI ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons / square. *Requires torch -applied cap membrane. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • ""• • • FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, • • • • • '.. • Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, •' • ••• • •••••• Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, ••••••• •••••• Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt • ••••• •• • • • • applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY • • • • • • ••••• • • • •. • •Modified Adhesive at 1.5 — 2.0 gallons / square. to sand • •.•••• ••••• • •• •• .. .. •• .. •••••• • Surfacing: • • • • • ; Surfacing is Optional on granular surfaced field cap membranes. •• •; •• • • • • • • • • Surfacing is Required for smooth or sanded surfaced field cap membranes. •• • • •' • • Refer to Underwriters Laboratories or Intertek Testing Services listings for •• applicable fire classifications. • • Apply any coating listed in Table 4 above, or any Miami -Dade approved Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene Maximum Design Pressure: MIAMI DADE COUNTY APPROVED coating system. -255 psf. (using ENRGY 3, H -Shield, Sopra-ISO r , M -Shield) (See General Limitation #9.) -270 psf. (using ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s) (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 86 of 160 Membrane Type: SBS Deck Type 3L• Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(35): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: (Use only if Vapor Barrier installed) Elastocol 500 or ASTM D41 at 0.75 gal./sq. Vapor Barrier: - Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, (Optional) Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched -applied to primed concrete deck. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' ACFoam-II, Sopra-ISO s, ACFoam-III, Sopra-ISO+ s, EnergyGuard POLYSIO Insulation, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield, Sopra-ISO r, M -Shield, H -Shield CG, Sopra-ISO+ r, Multi -Max FA -3, Sopra-ISO x Minimum 2" thick N/A N/A Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Sopraboard Minimum 0.125" thick N/A NLA• • • • • .... • • SECUROCK Gypsum -Fiber Roof Board, DensDeck, DEXcell FA Glass Mat Roof Board •• •. ••. •• • Minimum 0.25" thick N/A N/A 6 • .... .. DEXcell Cement Roof Board • • • • • Minimum 7/16" thick N/A 11/4t•• •. • • .. .. ..• •. Note: All insulations shall be adhered with Duotack or Duotack Neo applied inFoliauons ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS6117 Ibr ins ktjQg attachment. Insulations listed as base layer only shall be used only as base la'ers *ytith a %econd layer of approved top layer insulation installed as the final membrane substrate... ' • Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded • MIAMFDADE COUNTY APPROVED 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Ply or Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 87 of 160 • .' . Ply Sheet: (Optional) Membrane: .... . . .... Surfacing: . ".. . . . .. . • .. • • • .. • • • • • • Maximum • •••• •••• • • .. • Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Ply or Cap. Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV Alu Sanded, applied in hot asphalt at 25 lbs./sq. or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. 'Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for Applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating .system. DDsign.Press3irr: • • • • • ••• • .. :-260 psf. (See General Limitation #9.) MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 88 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(36): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Primer: (Use only if Vapor Barrier installed) Elastocol 500 or ASTM D41 at 0.75 gal./sq. Vapor Barrier: Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, (Optional) Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched -applied to primed concrete deck. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ACFoam-III, Sopra-ISO+ s, EnergyGuard POLYSIO Insulation, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield, Sopra-ISO r, M -Shield, H -Shield CG, Sopra-ISO+ r, Multi -Max FA -3, Sopra-ISO+ x Minimum 2" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/ANNS • • • . . . • .. . .. . . Note: All insulations shall be adhered with Duotack or Duotack Neo applied in cggtjggous rjbllggS • maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS .1.1X for insulation • • attachment. Insulations listed as base layer only shall be used only as base layors•with a aocond • . layer of approved top layer insulation installed as the final membrane substrate. •••• • • • Base Sheet: ElastopheneElastopheneColphene HS 62 Sanded,Col hene Sanded ElassoP here Sanded • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sags e�c� y2, Colpieie 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, applied iQ COLPLY • EF Adhesive at 1.5-2.0 gal./sq. • or Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. Ply Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded (Optional) 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, applied in COLPLY EF Adhesive at 1.5-2.0 gal./sq. Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV AIu Sanded, applied in COLPLY EF Adhesive at 1.5-2.0 gal./sq. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 89 of 160 • • • • Surfacing: Maximum Design Pressure: .. 0 . 0000 . Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -260 psf. (See General Limitation #9.) • .. . . . .. .• .. .• . .. • . • • • • • • .. 0000 • • • • 00 • 0000 • . . • • • • ...... .. • • • • • • • • • • • • ••• • .. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 90 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(37): One or more layers of insulation adhered with approved adhesive onto vapor barrier adhered onto concrete deck. All General and System Limitations apply. Vapor Barrier: Elastophene Stick, Sopralene Stick or Colphene Stick self -adhered to concrete deck primed with Elastocol Stick Zero applied at a rate of 0.5 gal./sq., One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation Minimum 1.5" thick N/A Top Insulation Layer Insulation Fasteners (Table 3) N/A Fastener Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A ' • ' .... DEXcell FA Glass Mat Roof Board, DensDeck, SECUROCK Gypsum -Fiber RootJdaill • • • Minimum 1/4" thick • . • N/A • NNA •• • DEXcell Cement Roof Board ••••• • • • •. . •• • • . • • Minimum 7/16" thick N/A• • • • NPA • . •••• . • • Note: All insulations shall be adhered to the vapor barrier with Duotack or Dggti Neo •. in Y2" to' " wide ribbons spaced maximum 12" o.c. Refer to Roofing Applicat4onStandar0 RATS • 117 for insulation attachment. Insulations listed as base layer only shall be used only as base3'fiSTEfs' • • with a second layer of approved top layer insulation installed as the final membraete sutstrate.. . . • • Primer: Top insulation layer primed with Elastocol Stick Zero applied at a rate of 0.5 •• gal./sq. Base Sheet: One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick*, Sopralene Flam Stick* self -adhered. *Requires torch -applied cap membrane. MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 91 of 160 Membrane: Surfacing: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Or Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -270 psf. See General Limitation #9.) . • •••• • • • . • • • •• • •• • • • • •• • • • • • • • • •• •••• • • • • • •• • •••• • • •• • • • • • • • •• •• •• •• • •• • • • • • • • • • • • • • • • • • • • • • • MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 92 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(38): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer- Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ACFoam-III, Sopra-ISO+ s, EnergyGuard POLYISO Insulation, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield CG, Sopra-ISO+ r Minimum 2" thick N/A N/A Top Insulation Layer Sopraboard Minimum 0.125" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A DEXcell FA Glass Mat Roof Board, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 1/4" thick DEXcell Cement Roof Board Minimum 7/16" thick N/A N/A N/A . .••• • • • ' .• • •• • • Note: All insulations shall be adhered with Duotack or Duotack Neo applied in 4qAtiquous rtbMus' • maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117:frnr insulation • . attachment. Insulations listed as base layer only shall be used only as base laxens•with a teconJ. • • layer of approved top layer insulation installed as the final membrane substrate. • • • • • • • Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastopliene Sanded • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Saiiclee1,;.;, Colpheqe • • 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastbphline PS*,. • • Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* r Soiplalenerft ' . PS* applied in hot asphalt at 25 lbs./sq. • • • • • • • • • Or •• MIAMFDADE COUNTY APPROVED Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Ply or Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 93 of 160 Ply Sheet: (Optional) Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. Or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV Alu Sanded, applied in hot asphalt at 25 lbs./sq. Or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 • •••• . FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. .••. • • • S irfaging: Surfacing is Optional on granular surfaced field cap membranes. •• `` '• Surfacing is Required for smooth or sanded surfaced field cap membranes. • • • • Refer to Underwriters Laboratories or Intertek Testing Services listings for •• • - • • • . • • • • •applicable fire classifications • • • • ' • •' Apply any coating listed in Table 4 above, or any Miami -Dade approved coating• • • • • • • • system. • Maximum • • Dtsig;Pressprr: 277.5 psf. (See General Limitation #9.) • • • • • •• • • • • • ••• • •• MIAMI DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 94 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(39): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer - Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ACFoam III, Sopra-ISO+ s, EnergyGuard POLYISO Insulation, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield CG, Sopra-ISO+ r Minimum 2" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with Duotack or Duotack Neo applied in continuous ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, E1asophene San&4 • • • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 SAW 2�, Col -lents •. 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elasioitane PS*,. •..' • Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS*17t'9opralene 180 • • PS* applied in hot asphalt at 25 lbs./sq. ••••• •• • • ....• .• .. Ply Sheet: (Optional) MIAMMDADE COUNTY APPROVED Or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene FlaW,$opralene•Va 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene 1 '42,;Colphene€P 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0' Sopralene laQ•$$ • 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Ply or Cap. Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. . . .. Or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 95 of 160 • • . . Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV Alu Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: _285 psf. (See General Limitation #9.) • • . 0000 41 . • • . • • • .41 • .. • • • • .. • 41 • 41 41 . • 41. .41.. • • • • • •• • 0410. • • • • • • • .. -. 41. .. . • • • • • • . • • • • • • • • ... . .41 MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 96 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(40): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ACFoam III, Sopra-ISO+ s, EnergyGuard POLYISO Insulation, ENRGY 3 AGF, ENRGY 3 CGF, H -Shield CG, Sopra-ISO+ r Minimum 2" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A Note: All insulations shall be adhered with Duotack or Duotack Neo applied in continuous ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Base Sheet: Ply Sheet: (Optional) Membrane: Surfacing: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Co1Q1N e 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, applied in coml. • EF Adhesive at 1.5-2.0 gal./sq. . • • • . . .• Or • • •• Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Co1pl.SP 3.0,..• . Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP cos3SSoprallne.. • 250 SP, torch -applied. • . Elastophene HS 62, Elastophene Sanded, Colphene Sanded, ElasTilRene Sanded • • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sitaecl'i.2, Colphene 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, appliei1 in COI,t ' . EF Adhesive at 1.5-2.0 gal./sq. • • •• Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR G11,• Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in COLPLY EF Adhesive at 1.5-2.0 gal./sq. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -285 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 97 of 160 . . . . • • • • Membrane: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(41): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Vapor Barrier: Two layers of Elastophene Stick, Sopralene Stick, Colphene Stick, self -adhered (Optional) 'to concrete deck primed with Elastocol Stick or Elastocol Stick Zero at 0.5 gal/sq. Or One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 250 SP, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5 or Colphene 180 SP 3.5, torch -applied to a layer of Colvent Flam TG or Colvent Flam 180 TG, torched -applied over deck primed with ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation Minimum 1.5" thick (flat or tapered) N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 S1 tJROCK Gypsum -Fiber Roof Board •••• Njinig�um '/a: thicl� N/A N/A Ale: Top la.y.erdoinsulation shall be adhered with Duotack or Duotack Neo applied in 1/2" to 3/4" • wide ribbons timed 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation • attghtnent. ¶JuulJtions listed as the base layer shall only be used as the base layer with a second l iyerof appnot, top layer insulation installed as the final membrane substrate. Composite i•nsu4ation boardsysed as a top layer shall be installed with the polyisocyanurate face down. • • Bgse Sheet:: • : One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, • • Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene •• • . ... • • • • • HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 • • • ' Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. • • Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied to substrate primed with Elastocol 500. Or MIAMI•DADE COMITY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 98 of 160 Base Sheet: One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene (Continued) Flam Stick* or Sopralene Flam Stick*, self -adhered to substrate primed with Elastocol Stick or Elastocol Stick Zero. *Requires torch -applied ply or cap membrane Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Membrane: Surfacing: Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered. *Requires torch -applied ply or cap membrane Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR4,• Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colpherg Flap 180 (itt,., • Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sop'raleheFlam 1$0 . Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 18AMI4GR 3.5; '..' Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Srcfnatene Flam 251i Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 25DTRI-.GR, :•• • Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antiroctc,'tolch-appried' • Or Elastophene GR, Elastophene FR GR, Elastophene LS FR Gi ,'$tasiophene Flt+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 l'R GJ, Sopraktre• • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR•QLt! Q 1phege,;50. FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV.: Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design -315.0 psf. With Self -Adhered Vapor Barrier (See General Limitation #9) -382.5 psf. (See General Limitation #9) Pressure: MIAM4DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 99 of 160 . � • .. • flysheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded • • (Optional) 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene • • • .. • • • • 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, applied in COLPLY • • • ••• Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(42): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All insulations shall be adhered with Duotack or Duotack Neo applied in continuous ribbons maximum spacing of 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, applied in COLPLY EF Adhesive at 1.5-2.0 gal./sq. Or Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, • • • • Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 • • •"' :SP, torch -applied. • • • • • • EF Adhesive at 1.5-2.0 gal./sq. Memtrane:• • 4.• • • Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, • •Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 • • • • • • FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, • • • • Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU • • • • • • S •anded, applied in COLPLY EF Adhesive at 1.5-2.0 gal./sq. Sif rfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: MIAMIDADE COUNTY APPROVED -337.5 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 100 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(43): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Vapor Barrier: One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene (Optional) SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched -applied to concrete deck primed with asphaltic primer at 0.75 gal/sq. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A •... . . .•.. DEXcell FA Glass Mat Roof Board, DensDeck, SECUROCK Gypsum -Fiber RoofSoard .. • •Minimum 1/4" thick N/A N/A • • • • • . . DEXcell Cement Roof Board .•••• •• • •Minimum 7/16" thick N/A • • N/A. .• . . . • . •. • Note: All insulations shall be adhered to the vapor barrier or deck with DuotaeJ,g Ruotack Nfo . applied in 'A" to'/" wide ribbons spaced 12" o.c. Refer to Roofing Application Stantla}d RA,S 117 •• for insulation attachment. Insulations listed as base layer only shall be used only as base tnYe1 • with a second layer of approved top layer insulation installed as the final membrane sutstrate.•.• . . • Base Sheet: One or two plies of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, • • Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded or Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-25 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, self -adhered. MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 101 of 160 Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive or COLPLY Modified Adhesive at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, self -adhered. Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design -337.5 psf. If ply sheets are used (See General Limitation #9.) Pressure: -382.5 psf. (See General Limitation #9.) .•. • .... • • • •• • • • • .. • • • • • . .. .• . . .• • • • • • • . • .. . • • • •• • • •• •• • ..•• .. •. • • • • • • • • • •.. • • . • • .. MIAMIhOADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 102 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(44): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, Sopra-ISO s, ENRGY 3, H -Shield, Sopra-ISO r, M -Shield or Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer Sopraboard Minimum 0.125" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. •.... • Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, E1astotheae Sanded • • • • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sander2.2,•Colpliene. .. 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastopllwe S*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sppralene 1$Q PS*, applied in hot asphalt at 25 lbs./sq. • •.. • *Requires torch -applied Ply or Cap. • .• • •• • Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastgp jig,Sandedd • • • • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.Z, Colphene 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastorhene PS*, . Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* orfopr;lene 1.8+0. . PS* applied in hot asphalt at 25 lbs./sq. • • • Ply Sheet: (Optional) MANMADE COUNTY APPROVED or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 103 of 160 Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: Maximum Design Pressure: ••. • • • •• ••• • • • • • •• •• • • • • •• • •••• • • •• • • •• •• • • • • • • • • • • .• •• • • • • • •.• • • •• •• •• • • • • • •• • • •• •• Or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam Ultra FR GR, Sopralene Flam Antirock, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam 250 Ultra FR GR or Sopralast 50 TV ALU, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -365 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 104 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(45): SBS Concrete Decks, Insulated Min. 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All General and System Limitations apply. Vapor Barrier: One or two plies of Elastophene SP 2.2, Colphene SP -2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torched applied to ASTM D 41 primed concrete deck. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r, ENRGY 3, Multi -Max FA -3, Sopra-ISO x (flat or tapered) Minimum 2" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered in High Velocity® Insulation Adhesive III (HVIA-III), High• • •. Velocity® Insulation Adhesive III — Green, High Velocity Insulation Adhesive PG, D•gatask, • • • Duotack Neo, Millennium One Step Foamable Adhesive, Millennium One Step Green y'.gpmabt •. • • Adhesive, Millennium PG -1 Low Viscosity Insulation Adhesive or OlyBond 500 applied in 'h" to . '/" wide ribbons spaced 3" o.c. Please refer to Rooting Application Standard RAS I4 d'or .. . insulation attachment. Insulation listed as base layer only shall be used only as base layers with ;• • • second layer of approved top layer insulation installed as the final membrane subStT3f : .• • •: Base Sheet: Ply Sheet (Optional): Membrane: MIAMFDADE COUNTY APPROVED .• .. Colvent Flam TG, Colvent Flam 180 TG, Elastophene Flam, Elnstcphgne Flam • 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.1, Eiassophene SP, 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180: Sopr lene lib• • SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flim 250, • • • • Sopralene 250 SP, torch -applied. Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torched -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 105 of 160 • Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -375 psf. (See General Limitation #9.) •..• . • SSSS • • •• • •• • • •• • • . • •• • • • •• • • • • • • • •• •• • • • • • • •• • •SS• • • SSSS • • •• •• . • ••• • • • • • • • • • • 0 . • • • • • • • • • • • MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 106 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(46): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftV ACFoam II, Sopra-ISO s, ENRGY 3, H -Shield, Sopra-ISO r, M -Shield, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final • membrane substrate. •••• Base Sheet: Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam$, Sol3ralene Fiaihi'• • 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SPS 1 c olphe&SP •. .. 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, SPAT:!re 180 SP.. • • 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. • • • • • •••••• .•. . *Requires torch -applied Ply or Cap. •••• .. • Ply Sheet: Elastophene •HS 62, Elastophene Sanded, Colphene Sanded, Elastop•.hen eSanded� •• . • • (Optional) 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanckil•2•.:• Colphene • 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, ElastoPhefle VS*, . � • Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* of Sopralene 1:3U"" • • PS* applied in hot asphalt at 25 lbs./sq. ° • • •• • or • • MIAMI.DADE COUNTY APPROVED Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 107 of 160 Membrane: Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV Alu Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -375 psf. (See General Limitation #9.) •.. • • • •• • • • • •• •• • • • • . • •• •• • . • • • . • • .••• . • . • • •. • ••.• • • • • • •• •• • • •. .. • ••• • • • • • • • • • . • . ..• • • . • •• .• MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 108 of 160 Membrane Type: Deck Type 3I: Deck Description: SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank System Type A(47): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Vapor Barrier One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene (Optional) SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied over concrete deck primed with asphaltic primer at 0.75 gal/sq. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, M -Shield, Sopra-ISO r, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, H -Shield CG, Sopra-ISO+ r, M -Shield CG, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard Polyiso Insulation Minimum 1.5" thick N/A N/A Top Insulation Layer Sopraboard Minimum 1/8" thick DEXcell FA Glass Mat Roof Board, Minimum 1/4" thick DEXcell Cement Roof Board Minimum 7/16" thick N/A N/A Insulation Fasteners Fastener (Table 3) N/A Density/ft2... . •..•. • . . •• • N/A••• • • DensDeck, SECUROCK Gypsum -Fiber Roofaiard N/A••••• .... . . .. .. . .. NSA.N. • . .• . . .. .. • . • • • Note: All insulation shall be adhered to the vapor barrier or deck with Duotack,or Uuotack5'fet • S • applied in Y%" to %" wide ribbons spaced 12" o.c. Refer to Roofing Application Starfdhrd RAS J17. for insulation attachment. Insulations listed as base layer only shall be used only as base layers •.: with a second layer of approved top layer insulation installed as the final membrane substrate. Base Sheet: Ply Sheet: (Optional) MIAMI.DADE COUNTY APPROVED One layer of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Colvent Flam TG, Colvent Flam 180 TG, torch -applied. Or One layer of Elastophene Flam Stick, Sopralene Flam Stick, self -adhered. One layer of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Colvent Flam TG, Colvent Flam 180 TG, torch -applied. Or One layer of Elastophene Flam Stick, Sopralene Flam Stick, self -adhered. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 109 of 160 • Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -382.5 psf. (See General Limitation #9.) 000 • • 0000 • • • • • • •• • •• • •• • • • • • • • • •• •••• • • • • • •• • •••• • • • • • • • •• •. •• •• • • • • • • • • • • • • • • • • • • • 000 • • • MIAMMDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 110 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(48): One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ENRGY 3, H -Shield, Sopra-ISO r, M -Shield, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick Insulation Fasteners (Table 3) Fastener Density/ft2 N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. Refer to Roofing Applica• ion Standard RAS 117 for insulation attachment. Insulations listed as base layer wily shall be•tiged • only as base layers with a second layer of approved top layer insulation instlikaa as the.Onal membrane substrate. • Base Sheet: Elastophene HS 62, Elastophene Sanded, Colphene Sanded, ElastOVene Sanded • 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded'Le3, Colp�ieae • • 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, ElastgpJteJig PS*, • • •. • Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* pr.Sgpc•alene ?$Q • PS*, applied in hot asphalt at 25 lbs./sq. . *Requires torch -applied Ply or Cap. • Ply Sheet: (Optional) MIAMIOADE COUNTY APPROVED Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elasttpbenc Sandici• . 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colphent.: 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. Or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 111 of 160 • • • Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: •. • • ••••• • • • • • • • • • • •• • • ▪ • •• •••• • • • • •• • •••• • • • • • • • • • • • • • • • • -397.5 psf. (See General Limitation #9.) • • •• • • • 1 • 4, . • • •• • • • • • • • • • • MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 112 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(49): One or more layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, H -Shield, M -Shield, Sopra-ISO r Minimum 1.4" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Fesco Board Minimum 1/4" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of insulation. All insulation shall be adhered to the primed deck in full moppings of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base.laye'r. only shall be used only as base layers with a second layer of approved top layer impatgon installed as the final membrane substrate. Composite insulation panels may be used as 0.tAR Layer plattsl• • with the polyisocyanurate side facing down. . Base Sheet: One or more layers of Sopra G, Modified Sopra G, Sopra-N, S0 00 : • • . . • (Optional) Soprabase, Soprabase S adhered in a full mopping of approved�,e)�41t applied • within the EVT range and at a rate of 20-40 lbs./sq. ..' ..' .. • •.; Ply Sheet: (Required if no base sheet used) One or more layers of Elasophene Sanded, ' (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastchane• HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 18J aided, • Sopralene 180 Sanded 2.2, Soprabase, Elastophene PS*, Elastophene PS 3.0*, •.: Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Type IV or Type VI ply sheets, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. *Requires torch -applied cap membrane. Membrane: MIAMI.DADE COUNTY APPROVED Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 113 of 160 • • . • Membrane: (Continued) Surfacing: Maximum Design Pressure: • • • •• • • •• • • • • • • • •• • • • • • • • • •• •••• . • • ••• • •••• • • • • • • ••• •• •• • •• • • • • • • • • • • • • • • • • •• • • • • ••• • •• MIAMI-DADE COUNTY APPROVED Or Elastophene FR GR, Elastophene FR+ GR, Elastophene LS FR GR, Elastophene GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -420 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 114 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(50): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive. All General and System Limitations apply. Primer: Substrate primed with approved ASTM D41 primer. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' ACFoam-II, Sopra-ISO s, ENRGY 3, H -Shield, Sopra-ISO r, M -Shield, Multi -Max FA -3, Sopra-ISO x Minimum 1.5" thick N/A Top Insulation Layer Insulation Fasteners (Table 3) N/A Fastener Density/ft2 DensDeck Minimum 0.25" thick N/A N/A Note: All insulations shall be adhered with hot asphalt at 25 lbs./sq. Refer to Roofing Applicq_ipp Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be.used' only as base layers with a second layer of approved top layer insulation installe'd Is the Anal . membrane substrate. • •, • Base Sheet: Ply Sheet: (Optional) MIAMI•DADE COUNTY APPROVED Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sand; d.2. , Colon . �• 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastpp$v>Ie*PS*, • • Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* o; Sopfalene I$p'.: PS*, applied in hot asphalt at 25 lbs./sq. • • . . *Requires torch -applied Ply or Cap. • Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elasft 1t'n$ Sand:O. . 2.2, Elastophene Sanded 3.0, Elastophene HS, Sopralene 180 Sanded 2.2, Colpherfe.: 180 Sanded, Sopralene 180 Sanded, Sopralene 250 Sanded, Elastophene PS*, Elastophene PS 3.0*, Sopralene 180 PS 2.2*, Colphene 180 PS* or Sopralene 180 PS* applied in hot asphalt at 25 lbs./sq. or Elastophene Flam HS*, Elastophene Flam 2.2*, Elastophene Flam*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene 250 SP, torch -applied. *Requires torch -applied Cap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 115 of 160 • • Membrane: Soprastar Sanded, Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Elastophene FR+ GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR or Sopralast 50 TV ALU Sanded, applied in hot asphalt at 25 lbs./sq. Surfacing: Maximum Design Pressure: ... • • .... • • •• • • • •• • •• • •• • • • or Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam Ultra FR GR, Sopralene Flam Antirock, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam 250 Ultra FR GR or Sopralast 50 TV ALU, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. • • • . •..• • • •• • • .• • ••.. • -452.5 psf. (See General Limitation #9.) • • • • • • • •• •• •• •• • • • • • • • • • • • • • •• • • • • • ••• • •• 00 MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 116 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(51): Substrate Preparation: SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. All General and System Limitations apply. Primer: Vapor Barrier (Optional): Substrate primed with approved ASTM D41 primer One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Colvent TG, Colvent 180 TG, torch -applied. Or One layer of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. Leveling Agent Poly Patch (Optional): One or more layers of any of the following insulations. Base Insulation Layer ACFoam-H, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, or any approved polyisocyanurate listed in Table 2 Minimum 2" thick Top Insulation Layer Sopraboard • .•• . . . • •••• Insulation Fasteners • • • Fastener • • (Table3) •••;• H -Shield, M -Shield, Sopra % tt N/A 'Density/ft=• 1F •••• .. • • • • •••• N/A •• • • • Insulation Fasteners • • • • • Fastener • • (Table 3) . . .Density/ft2 •• . . Minimum 1/8" thick N/A : • • • NPA •. • •.• • Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to: application of vapor barrier or insulation. All insulation shall be adhered to the vapor barrier or primed deck in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., (Optional) to top surface of any insulation, base or ply sheet prior to application of next layer Base Sheet: One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 117 of 160 Base Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene (Continued) Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS* Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene Sanded*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to five plies of Sopra G, Modified Sopra G, Type IV or Type VI ply sheet adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot • asphalt at 25 lbs./sq. to sand surfaced base membrane. • • ••••• • •• • *Requires torch -applied cap membrane. Me'rane: • • •, m • Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, • •• • Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene • • • • • •.. • Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene • •• • •• • Flam 180 FR nn Sopralene >,tam ton FR GR 3.5, Sopralene Flam t t en r > n. n • • •• GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam • • • • • • • • 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, ••• • • Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • • • • • • • • ••• •• Surfacing: • • Or •• • • •• •• Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced base or ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -502.5 psf. (See General Limitation #9.) MIAMI.OADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 118 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type A(52): Substrate Preparation: SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank One or more layers of insulation adhered with approved adhesive All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. All General and System Limitations apply. Primer: Vapor Barrier (Optional): Substrate primed with approved ASTM D41 primer. One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Colvent TG, Colvent 180 TG, torch -applied. Or One layer of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Soprabase, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. Leveling Agent Vinyl Patch (Optional): One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners • • ety • Faster• • (Table 3) •. Densifyiftt• ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, H -Shield. M -Shield, Sopra 1 t? r • • • or any approved polyisocyanurate listed in Table 2 • Minimum 2" thick N/A • •••• ••• • NZ'A• • 1 •• Top Insulation Layer Insulation Fasteners . • Fastenor Sopraboard Minimum 1/8" thick N/A (Table 3) • •• Densify/fP• • • • • • • • IVR•••. • • • , . Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry priori application of vapor barrier or insulation. All insulation shall be adhered to the vapor barrier or primed deck in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) Base Sheet: MIAMI.DADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of next layer. One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 119 of 160 Base Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene (Continued) Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, or one to five plies of Sopra G, Modified Sopra G, Type IV or Type VI ply sheet adhered in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. to sand surfaced base membrane. • • • *Requires torch -applied cap membrane •••• • •• 1�embrane:' • ..• Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, • Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene • • • • Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, • • • • •• •• • • • Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam •• • • • • • • • •••• 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, • • • • • • • Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam • • •• 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. • • • • • • • • Or ' •• • •Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ • •• • • • GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surface base or ply membrane. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -525 psf. (See General Limitation #9.) MIAMI.DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 120 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type B(1): Base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum '/2" thick 24 (#14 MP or #15 HD), 13 1:2 ft2 or 14 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening details. Primer: (Optional) Vapor Barrier: Elastocol 500, Elastocol Stick Zero or Elastocol Stick at a rate of 0.5 gal/sq. Sopravap'r, Elastophene Stick, Sopralene Stick or Colphene Stick, self-adheltly•. • .... • • • . .•• • •• • . •• .• • . • •• over primed gypsum board. Or . Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colpjepv SP 3.Q. •. Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 S1�'i4eopralebe...` 250 SP, torch -applied over primed gypsum board. . : .• .• •• .. Or . Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2!2, Elaatophejg..;. Sanded 3.0, Elastophene HS, Elastophene 180 Sanded, Colphrin e 1.$0 Sanded Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 2M Sanded, 6. . . Elastophene PS, Elastophene PS 3.0, Elastophene 180 PS, Colphene 180 PS, Sopralene 180 PS 2.2, adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY Adhesive, COLPLY Modified Adhesive at a rate of 1.5 gal./sq Middle Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, H -Shield CG, M -Shield, Sopra-ISO r, Sopra-ISO+ r, ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, Multi -Max FA -3, Ultra -Max, Sopra-ISO x, ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, EnergyGuard POLYISO Insulation Minimum 1.5" thick (flat or tapered) N/A N/A Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 1/4" thick MIAMI.DADE COUNTY APPROVED Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 121 of 160 • • • *0(000 • • • • • • Note: Top layer of insulation shall be adhered with Duotack or Duotack Neo applied in %" to' " wide ribbons spaced 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: 0000 • • 0000 . • •• . • • •. •. • • • •• . . • . . • • • .• •••• • • � heet: •••••• 0Optl pal) • .• •. •. .. 000.'00 • . • • • . • • • • .• . . . . • . ... . .. .. MIAM4DADE COUNTY APPROVED One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied to substrate primed with Elastocol 500. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered to substrate primed with Elastocol Stick or Elastocol Stick Zero. *Requires torch -applied ply or cap membrane One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered. *Requires torch -applied ply or cap membrane NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 122 of 160 Membrane: Surfacing: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) MIAMI•DADE COUNTY APPROVED .... • • • •••• • • • • •• • •• • •• • •• • • •' • • • •••• •• • • • • • • .••• • •• •. • • •• •• • • •• • • •• • • • • • • • • • • • • • ••• • • • • �• ••. • • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 123 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type B(2): Base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations apply. Thermal Barrier: Min. '/4" thick DensDeck or DensDeck Prime, loose -laid. (Optional) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 H -Shield, M -Shield, Sopra-ISO r, ACFoam-II, Sopra-ISO s Minimum 2.0" thick (flat or tapered) 24 (#14 MP or #15 HD), 13 1:1.6 ft2 or 14 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening details. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SM1T ROCK•Gyp um -Fiber Roof Board •. Minim'/e um'thiek N/A N/A • NW: 'Top layer of insulation shall be adhered with Duotack or Duotack Neo applied in %" to %" • wide ribbons ,Sgaced 12" o.c. Refer to Roofing Application Standard RAS 117 for insulation • • • attgehtnent. Tpplftions listed as the base layer shall only be used as the base layer with a second • • Isiyerpf appr wed•top layer insulation installed as the final membrane substrate. Composite insulation boardsiused as a top layer shall be installed with the polyisocyanurate face down. • • Base Sheet: . . • One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, • • Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene • ••• • HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 •• • '• • Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, • • Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied to substrate primed with Elastocol 500. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered to substrate primed with Elastocol Stick or Elastocol Stick Zero. *Requires torch -applied ply or cap membrane MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 124 of 160 Ply Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Elastophene Sanded, (Optional) Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS* or Sopralene 250 Sanded adhered in hot asphalt at 25 lbs./sq. or applied in COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive applied at a rate of 1.5 — 2 gal./sq. Membrane: Surfacing: Or One layer of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. Or One layer of Elastophene Stick, Sopralene Stick, Colphene Stick, Elastophene Flam Stick* or Sopralene Flam Stick*, self -adhered. *Requires torch -applied ply or cap membrane Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 14(11. Ultra FR GR, Colphene Flam 180 FR GR, Sopralene Flam 189 FR OR 3.5,'....' Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Sopralene Flam950. Ultra FR GR, Colphene Flam 250 FR GR, Sopralene Flam 256'P1 +'GR, • • • Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam AntiroeR,'tbt'Z'h-applied' ..•. .. . Or • •• •• . •• Elastophene GR, Elastophene FR GR, Elastophene LS FR G1t,11.asfophene F1 +; GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 t •ti Sopra%ne" 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR•'GRR CpIpher1e 25Q FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR,SoNa1ast 5(CTN • • Alu Sanded adhered in a full mopping of approved asphalt appiiet within the. . EVT range and at a rate of 20-40 lbs./sq. or in COLPLY Adhesive, COLPLY .: Modified Adhesive, COLPLY EF Adhesive at 1.5-2.5 gal./sq. to sand surfaced membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 125 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type C: All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r, ISO 95+ GL, ENRGY 3 Minimum 2" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer SECUROCK Gypsum -Fiber Roof Board Minimum 'A" thick Insulation Fasteners Fastener (Table 3) Density/ft2 8 (#12 or #14), 2 (#12 or #14), 24 (#12) 1:1.78 Note: All layers of insulation shall be mechanically attached using the fastener density listed al ove.The insulation panels listed are minimum sizes and dimensions; if larger panels are used, • ttie number pf1 ttners shall be increased maintaining the same fastener density. Refer to Roofing • • �R�IiQation $tavdard RAS 117 for insulation attachment. • • • Primer: • •«ptf nal) five SJleet: •. • • • •• • •••• • • •••• • • •• •• • • • • • • •• • • • • •• • • • ••• •• MIAMFDADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of next layer One or more layers of Sopra G, Modified Sopra G, Sopra-IV, Sopra-VI, Soprabase, Soprabase S, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in a full mopping of approved asphalt, applied within the EVT range and at a rate of 20-40 lbs./sq. Or Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. *Requires torch -applied ply or cap membrane. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 126 of 160 Ply Sheet: One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene (Optional) Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. Membrane: Surfacing: Or Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS,-Elastophene FIS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in a full mopping of approved asphalt, applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. •• •• •• •• • •••• Or •••• • •• • Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, lntophene ! R+� • GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR,,Q. Sopraliie • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR,.CprpheneVN, • • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR adhered in a full mopping of approved asphalt applied within the EVT range and nt aYate of /Osla.: lbs./sq. or in COLPLY EF Adhesive, COLPLY Adhesive, COIrfYIglodified • Adhesive at 1.5 — 2.0 gallons/square to sand surfaced base or pfy menlbrane• • •• • Surfacing is Optional on granular surfaced field cap membranes.. : • ... • Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -60 psf. (See General Limitation #7.) MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 127 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(1): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Sopra-ISO s, Sopra-ISO+ s, ENRGY 3, Multi -Max FA -3, Sopra-ISO x, H -Shield, M -Shield, Sopra-ISO r (flat or tapered) Minimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard, Structodek High Density Fiberboard Roof Insulation Minimum 'A" thick N/A N/A Fesco Board Minimum 3/4" thick N/A N/A Ilei speck, SECUROCK Gypsum -Fiber Roof Board • 11itt num '/A' t4ij k N/A N/A • • •• • •••• • • StQraboard . •• Mlhimum 1/$"t1 k N/A N/A • • • •• •.•• Siete.: :Top laybt•sh• all have preliminary attachment, prior to the installation of the base/anchor the,,et: gt a ntiitildfum application rate of two fasteners per board for insulation boards having no Mansion greater'than 4 ft., and four fasteners for any insulation board having no dimension greater than:.ft.:All layers of insulation and base sheet shall be simultaneously fastened. See base/a§chor sheet below for fasteners and density. Refer to Roofing Application Standard RAS • • 1,17 DA insul$tibaaitachment. • 11ase Sheet: One layer of Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [X], Soprafix Base 614, Soprafix-e, Soprafix Base 641, Soprafix [F], Soprafix Base 613, Soprafix Base 610*, Soprafix Base 611*, Soprafix Base 630*, Sopralene Flam 180, Colphene Flam 180 or Sopralene Flam 250 fastened to the deck as described below: Fastening: *For use only when using 2 in. diameter plates. Attach base sheet using Dekfast 14 fasteners with Dekfast 2" Round Barbed Seam Plates or Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed Plates or Soprema #14 fasteners with Soprafix 2" SB Stress Plates or Soprafix 2-3/8" SB Stress Plates or Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Trufast 2.4" Scoop Seam Plates or Soprema #15 HD Fasteners with Soprema 2" Seam Plates or Soprema 2.4" Seam Plates 12" o.c. in a 5" torch - applied lap. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 128 of 160 Ply Sheet: One or more layers of Elastophene Flam, Elastophene Flam 2.2; Elastophene (Optional) Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 -GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Colphene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, Soprafix Cap FR - 651, torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -60 psf. (See General Limitation #7.) .... • . • • • .••. • • • • •• . .• • • • •• • .. • • • • .•.• •• • • • • • .• •••• . . •• . . .. •. • • • . . • . • .. • • • • • • • • • • • • • •• • • • . �• • • ••• • • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 129 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(2): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete, Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A N/A Note: Load capacity of the structural substrate must be verified for the additional load of the LWC. The LWC must be properly vented. Middle Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, TppJlock DD, TopRock DD Plus, SopraRock DD, SopraRock DD Plus hitp.iigfum 1.5. thick N/A N/A • • . •. "# { ulati�-hax • • -er (Optional) Insulation Fasteners Fastener • (Table 3) Density/ft2 • • Sgpr• ulloard• .... Minimim '/89'•tb ek N/A N/A • • Ihitheck, Dt±plie& Prime, SECUROCK Gypsum -Fiber Roof Board •• Mipimum 'h': Chic& N/A N/A • • • . . • Net. 'op layer shall have preliminary attachment, prior to the installation of the base sheet. Ipsujatjon shD11'114limited to maximum 1" thickness. All layers of insulation and base sheet shall Ile.Simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Fastening #1:. Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Soprema #15 HD Fasteners with Soprema 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. in a 4" wide torch -applied base sheet side laps. (Meds Maximum Design Pressure of -67.5 psf; See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or Soprema #15 HD Fasteners with Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. in a 4" wide torch -applied base sheet side laps. (Meds Maximum Design Pressure of -75 psf; See General Limitation #7.) MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 130 of 160 Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (Optional) HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam .180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: See Fastening Requirements above. MIAMFDADE COUNTY APPROVED • • • •• •••• • •• • • •• • •• • • • • • • • •• • • • • •••• •• • • • • • • • • •.••• • • •• • • •• .• • • •• • . .. • • • • • • • • • • • •• • • • • •. • • ••. . • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 131 of 160 Membrane: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(3): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete, Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A N/A Note: Load capacity of the structural substrate must be verified for the additional load of the LWC. The LWC must be properly vented. Middle Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sopa-ISO x, TopRock DD, TopRock DD Plus, SopraRock DD, SopraRock DD Plus Mi, plum 1.5: thick N/A N/A • • • • . • T'bp•fiisulationlayer (Optional) Insulation Fasteners Fastener • (Table 3) Density/ft2 • • • SgprOoard • •.. Nl i itmlim 0.125'3 dick N/A N/A • • lbenheck, DepgPggk Prime, SECUROCK Gypsum -Fiber Roof Board • Mipimum 0.1•.1': thick N/A N/A • • • • N.tet.top lays r shill have preliminary attachment, prior to the installation of the base sheet. • Insu}atjon shall"tit limited to maximum 1" thickness. All layers of insulation and base sheet shall • • • l e, imultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Fastening #1: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2" Barbed Metal Seam Plates or Soprema #14 MP Fasteners with Soprema 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -67.5 psf; See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2.4" Scoop Seam Plates or Soprema #14 MP Fasteners with Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -75 psf; See General Limitation #7.) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 132 of 160 Fastening #3: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Soprema #15 HD Fasteners with Soprema 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. in a 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -120 psf; See General Limitation V.) Fastening #4: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or Soprema #15 HD Fasteners with Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. in a 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -142.5 psf; See General Limitation #7.) Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (Optional) HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirg1V • • • torch -applied. The 3" wide side laps of the cap sheets are tor& applied. •' • • • Surfacing: Surfacing is Optional on granular surfaced field cap membrane:..:.: : •.. • Surfacing is Required for smooth or sanded surfaced field caftfittrlbranes. • Refer to Underwriters Laboratories or Intertek Testing Services' IISthags fo ; • • • . applicable fire classifications. "" • • • • • Apply any coating listed in Table 4 above, or any Miami-Dada.appr,ved system. . . . . . .• • Maximum Design See Fastening Requirements above. • • • . . . Pressure: MIAMI.DADE COUNTY APPROVED •. • • . NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 133 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi concrete or concrete plank System Type D(4): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r (flat or tapered) Minimum 1.5" thick N/A N/A DensDeck, SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Sopraboard Minimum 1/8" thick N/A N/A Fesco Board, or Approved Perlite Insulation Minimum 0.75" thick N/A N/A Note:•Jnsulation layer shall have preliminary attachment, prior to the installation of the bat/Anchor sheet, *fit a minimum application rate of two fasteners per board for insulation boards ••• IIdviigno di$ienVon greater than 4 ft., and four fasteners for any insulation board having no di�ension grea;erthan 8 ft. All layers of insulation and base sheet shall be simultaneously ' ' fastened. See pp§e/anchor sheet below for fasteners and density. Refer to Roofing Application Slip ttla d RA%1LZTor insulation attachment. • • Base Sheet: One layer of Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, • • • • • • • •Soprafix [F], Soprafix Base 613, Soprafix Base [X], Soprafix Base 614, Soprafix-e �• • . . .or Soprafix Base 641, fastened to the deck as described below: F•asteeig: •. ..Attach base sheet using Trufast Recessed Batten Bar with Trufast #14 HD Fastener • • • •or Soprafix MBB -R with Soprema #14 MP Fasteners spaced 12" o.c. in the • ; •• minimum 5" wide lap. Ply Sheet: One or more layers of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (Optional) HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, Soprafix Cap FR -651, torch - applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 134 of 160 Surfacing: Maximum Design Pressure: MIAM4DADE COUNTY APPROVED Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -75 psf. (General Limitation #7) ... . . .• .... . . . . .. • .. • . • . • .. • . . .... .. . • . • • . • ....• . .. . . . • . . • . . ..• ....• .. . . • • •. . • . •• . . •• • . .. • ... • • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 135 of 160 • • • • . . • • Membrane Type: Deck Type 3I: Deck Description: System Type D(5): SBS Concrete Decks, Insulated Min. 2500 psi concrete or concrete plank All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer ACFoam-II, Sopra-ISO s, H -Shield, M -Shield, Sopra-ISO r Minimum 1.5" thick Top Insulation Layer (Optional) Approved High Density Wood Fiberboard, Structodek High Minimum 'A" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A Insulation Fasteners Fastener (Table 3) Density/ft2 Density Fiberboard Roof Insulation N/A N/A DensDeck Minimum '4" thick N/A N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimision gregter than 4 ft., and four fasteners for any insulation board having no dimension grrateAthan $ ft.. All layers of insulation and base sheet shall be simultaneously fastened. See base sheaf blow for fasteners and density. Refer to Roofing Application Standard RAS 117 for insulation attec%ent. B f Sbeet (Optional): 11%mgrane: . . . .• . • Surfacing: .... .... . . .. .. • . . • . . . • • . • .. Maximum Design Pressure: MIAMIOADE COUNTY APPROVED Sopra G, Sopra IV or Sopra VI presecured to the deck with approved fasteners and plates spaced 24" o.c. in the minimum 3" wide lap. One ply of UNILAY membrane fastened through the insulation to the deck using Dekfast 15 HS Fasteners or Soprema #15 Fasteners with Dekfast Isofast IF - 2.375 -AT Plates spaced 12" o.c. in a 5" wide lap. The side lap fastener row is encapsulated in the torch -applied lap. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -82.5 psf. (See General Limitation #7.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 136 of 160 Membrane Type: Deck Type 3I: Deck Description: System Type D(6): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank Base Sheet mechanically attached over preliminarily secured insulation All General and System Limitations apply. One or more layers of any of the following insulations Base Insulation Layer Any approved insulation board listed in Table 2 Minimum 1.5" thick Top Insulation Layer Insulation Fasteners (Table 3) N/A Insulation Fasteners (Table 3) Any approved coverboard board listed in Table 2 Minimum 1/4" thick N/A Fastener Density/ft2 N/A Fastener Density/ft2 N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Primer: (Optional) Base Sheet: Ply Sheet: (Optional) Membrane: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of nex! 4ayar• One layer of Soprafix, Soprafix Base 622, Soprafix [S], Soprafx ISS 612, •••• Soprafix [F], Soprafix Base 613, Soprafix-e or Soprafix Base 641' mechanidEfijy •. attached with OMG Polymer Batten Strip and OMG #15 Roofgnti.'arge Head fasteners, Trufast Flat Batten Bar and Trufast #15 EHD Fastener laprema • • • Soprafix MBB -R and Soprema #15 fasteners or SFS Dekfast Cbj1a„Batten pig. • and Dekfast #15 HS fasteners, spaced 12" o.c. in the min. 5" s sQlf-gagred lap, . One or more layers of Elastophene Flam, Elastophene Flam 2.2,.)•lacfopheneT-iast HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0tEo,hene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 2507Sopralene 1$Q J • 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 S1;,•Soprafik [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [xror Sopraf! r. Base 614, torch -applied. Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, Soprafix Cap FR -651, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -97.5 psf. (See General Limitation #7.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 137 of 160 • • . • . Membrane: Deck Type 3I: Deck Description: System Type D(7): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners (Table 3) Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete, Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A Fastener Density/ft2 N/A Note: Load capacity of the structural substrate must be verified for the additional load of the LWC. The LWC must be properly vented. Middle Insulation Layer (Optional) Insulation Fasteners (Table 3) ACFoam-II, Sopra-ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sopra-ISO x, TopRock DD, TopRock DD Plus, SopraRock DD, SopraRock DD Plus titi1mjim 1.5" thick •••• Tap Itisulati&ntayer (Optional) •Sopraboard ••Dtinithlim'/s;'t1i k .. • •.•. DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum '/e"•thick N/A • .• . . . Fastener Density/ft2 N/A N/A Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A N/A Note: fop layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation sh4ltbe limited to maximum 1" thickness. All layers of insulation and base sheet shall De SMlhltanebusljrfastened. See base/anchor sheet below for fasteners and density. •. Base Sheet: One layer of Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Fastening#1: Attach base sheet using Trufast #15 EHD Fasteners and Soprema #15 HD Fasteners with Trufast 2.4" Scoop Seam Plates and Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -97.5 psf; See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #15 EHD Fasteners and Soprema #15 HD Fasteners with Trufast 2.4" Scoop Seam Plates and Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -172.5 psf; See General Limitation #7.) MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 138 of 160 Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (Optional) HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED See Fastening Requirements above. ..• . . . . 0000 . . . . .. . .. . . • • • .. 0000 .• • • 0000 • 00 • • • 00 .. .. .. • • • • . • .. • • • • .. • .0. • 00 NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 139 of 160 • • • • Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(8): Base Sheet mechanically attached over preliminarily secured insulation All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any approved insulation board listed in Table 2 Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz Any approved coverboard board listed in Table 2 Minimum 1/4" thick N/A N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., (Qptipnal) to top surface of any insulation, base or ply sheet prior to application of next layer. • Base Sheet: • • • : One layer of Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, • •• •• •• • • • Soprafix [F], Soprafix Base 613, Soprafix Base [X], Soprafix Base 614 mechanically attached with OMG Polymer Batten Strip and OMG #15 Roofgrip • •••• Large Head fasteners, Trufast Flat Batten Bar and Trufast #15 EHD Fastener, • • •• • • • ....• Soprema Soprafix MBB -R and Soprema #15 fasteners or SFS Dekfast Batten Bar • • •and Dekfast #15 HS fasteners, spaced 12" o.c. in the min. 4" torch -applied lap. PlySheet: • • • • • One or more layers of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (OAtional) . . . HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, •• • Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP • • •• • • • 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250, •• • Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base •612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, Soprafix Cap FR -651, torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED -105 psf. (See General Limitation #7.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 140 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(9): Base Sheet mechanically attached over preliminarily secured insulation All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners (Table 3) Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete, Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A Fastener Density/ft2 N/A Note: Load capacity of the structural substrate must be verified for the additional load of the LWC. The LWC must be properly vented. Middle Insulation Layer (Optional) Insulation Fasteners (Table 3) ACFoam-II, Sopra-ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sopra-ISO x, TopRock DD, TopRock DD Plus, SopraRock DD, SopraRock DD Plus Minimum 1.5" thick N/A Top Insulation Layer (Optional) Sopraboard Minimum 1/8" thick Fastener Density/ft2 N/A••• Insulation FasteneA..Fastener. (Table 3) Dens'itynti' N/A •••••• Na. DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board •••• . •. Minimum '/" thick N/A • • • • • • NIA• • •' • Note: Top layer shall have preliminary attachment, prior to the installation of tie bas: sheet • Insulation shall be limited to maximum 1" thickness. All layers of insulation and babes heet ;hal be simultaneously fastened. See base/anchor sheet below for fasteners and density! Base Sheet: Fastening: Ply Sheet: (Optional) MIAMIDADE COUNTY APPROVED . ... . One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Trufast 2.4" Scoop Seam Plates or Soprema #15 HD Fasteners with Soprema 2" Seam Plates or Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. in a 4" wide torch -applied base sheet side laps. One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 141 of 160 Membrane: Surfacing: Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -112.5 psf; (See General Limitation #7.) *000 • • 0000 • • • • • • • • •• • •• • • • • •• • ••011•• • • • • • • 000* • • • • • •• • •••• • • • • • • • •• •• •• •• • • • • • • • • • • • • • • • • • • • • 000 • • • 00 MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 142 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(10): Base Sheet mechanically attached over preliminarily secured insulation All General and System Limitations apply. One or more layers of any of the following insulations Base Insulation Layer Any approved insulation board listed in Table 2 Minimum 1.5" thick Top Insulation Layer Any approved coverboard board listed in Table 2 Minimum 1/4" thick N/A Insulation Fasteners (Table 3) N/A Insulation Fasteners (Table 3) Fastener Density/ft2 N/A Fastener Density/ft2 N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Primer: (Optional) Base Sheet: Ply Sheet: (Optional) Membrane: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any insulation, base or ply sheet prior to application of next layer. One layer of Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612,•::::• Soprafix [F], Soprafix Base 613, Soprafix Base [X], Soprafix Bne6t4, • mechanically attached with OMG Polymer Batten Strip and Ol .,1 Roof rip,.' Large Head fasteners, Trufast Flat Batten Bar and Trufast #15 Fid .fastener • Soprema Soprafix MBB -R and Soprema #15 fasteners or SFS Dekfast Coilocb • • • Batten Strip and Dekfast 15 HS, spaced 6" o.c. in every other mtrtiMum 4" tbrcH' applied lap. Intermediate, non -fastened laps are 3" wide and tctit i= flied..' • One or more layers of Elastophene Flam, Elastophene Flam 2. ,.. ,Stophene Flgm HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0,:Coiplene Sl; 3.0,. Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250,Sopralene 1:6 51/ 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 256611, 4oprafix•[.j, • Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix • • Base 614, torch -applied. Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, Soprafix Cap FR -651, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -120 psf. (See General Limitation #7.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 143 of 160 Membrane: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(11): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete, Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A.. N/A Note: Load capacity of the structural substrate must be verified for the additional load of the LWC. The LWC must be properly vented. Middle Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sopra-ISO x, TopRock DD, TopRock DD Plus, SopraRock DD, SopraRock DD Plus 1V1tii'Mvm 1.5" thick N/A N/A • • Top In:ulatian veyer (Optional) Insulation Fasteners Fastener • 11.0 • (Table 3) Density/ft2 • • • Solfraboard ' • i iiinimrm 0.1e5"thick N/A N/A •• • ••b• • • 13egsDeck, D{M1Qeek Prime, SECUROCK Gypsum -Fiber Roof Board • POltninium 0.25'rthick N/A N/A • • • gtrej .Top layer sh• it Ill have preliminary attachment, prior to the installation of the base sheet. • • Insulatton shakbe limited to maximum 1" thickness. All layers of insulation and base sheet shall • • 1$e sihidltaneduslr'fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Fastening #1: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2" Barbed Metal Seam Plates or Soprema #14 MP Fasteners with Soprema 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Melts Maximum Design Pressure of -120 psf; See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2.4" Scoop Seam Plates or Soprema #14 MP Fasteners with Soprema 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -135 psf; See General Limitation #7.) MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 144 of 160 Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam (Optional) HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied. Membrane: Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: See Fastening Requirements above. MIAMI•DADE COUNTY APPROVED 000* • • •••• • • • • • •• • •• • • • . • • • • • • • • 0000 •• • • • • • • • Y ••0• •- •• • • • • • • • •• •• •• •• • • • • • • • • • • • • • • • • • • • • • •• • ••• • • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 145 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi concrete or concrete plank System Type D(12): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, H -Shield, ENRGY 3, Ultra -Max, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board, DensDeck, DensDeck Prime Minimum 0.5" thick 1, 24, 2, 13, 14 1:4 ft2 Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards AVM* no dimension greater than 4 ft., and four fasteners for any insulation board having no • • d!men. ion great than 8 ft. All layers of insulation and base sheet shall be simultaneously • futentd. Se f t s anchor sheet below for fasteners and density. Refer to Roofing Application • • Stgndard RQSW.1.7.for insulation attachment. • • prim: • • • • • • Coverboard is primed with an approved ASTM D41 asphalt primer at a rate of 100- • (Optidhal) • • • • 150 ft2/gal. • . . • • • $a%gOheet: • ••••• . • • • • • • • • •• . • . • • • • ••• • .. •• One layer of Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Soprafix, Soprafix Base 622, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X], Soprafix Base 614, Soprafix-e, Soprafix Base 641, Soprafix Base 610*, Soprafix Base 611*, Soprafix Base 630* fastened as specified below: *For use only when using 2 in. diameter plates. Fastening #1: Torch -applied base membrane to the coverboard with minimum 3" laps. Mechanically attach torch -applied base sheet with Soprema #14 fasteners or Soprema #15 fasteners and Soprema Soprafix 2" SB Stress Plates or Soprafix 2-3/8 in. SB Stress Plates, Dekfast 14 or Dekfast 15 HS fasteners with Dekfast IF -2 -SB or Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates spaced maximum 12" o.c. through the side laps and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -165 psf. See General Limitation #7.) MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 146 of 160 Fastening #2: Mechanically attach base sheet with Soprema #14 fasteners or Soprema #15 fasteners Soprema Soprafix 2" SB Stress Plates or Soprafix 2-3/8 in. SB Stress Plates, Dekfast 14 or Dekfast 15 HS fasteners with Dekfast IF -2 -SB or Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates spaced maximum 12" o.c. through the minimum 3" wide side lap and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -150 ptf. See General Limitation #7.) Ply Sheet: Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, Soprafix [F], Soprafix Base 613, Soprafix [S], Soprafix Base 612, Soprafix [X] or Soprafix Base 614, torch -applied with minimum 3" laps. Membrane: Elastophene Flam FR GR, Elastophene Flam GR, Elastophene Flam LS FR GR, Sopralast 50 TV Alu, Soprastar Flam, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, Soprafix Cap FR -651, torch -applied with minimum 3" laps. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. " ....• Refer to Underwriters Laboratories or Intertek Testing Services for • • • • : applicable fire classifications. . Apply any coating listed in Table 4 above, or any Miami -Dade appehe4 coating • system. • • • • • • • • • •••• • •• Maximum Design Pressure: See Fastening Options Above. •• • • • • •• •• MIAMI•DADE COUNTY APPROVED •• •• • • • • • •• • • • •• • • • ••• • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 147 of 160 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi concrete or concrete plank System Type D(13): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. • Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, H -Shield, ENRGY 3, Ultra -Max, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board, DensDeck, DensDeck Prime Minimum 0.5" thick 1, 2, 13, 14 or 24 1:4 ft2 Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously • '4%ej ed. See base/anchor sheet below for fasteners and density. Refer to Roofing Application • • Sta�rd RlkS.11'2 for insulation attachment. Primer: Coverboard is primed with an approved ASTM D41 asphalt primer at a rate of 100- ' • (Optional) 150 ft2/gal. .••• •Bae Sheet:' • • • • • One layer of Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, • . Sopralene 250 SP, fastened as specified below: • •• . . • • Fastening #1•' •• Torch -applied base sheet to coverboard with minimum 3" wide side lap. • ▪ • • • Mechanically attach torch -applied base sheet with Soprema #14 or Soprema #15 • • • fasteners and Soprema Soprafix 2" SB Stress plates, Dekfast 14 or Dekfast 15 HS • • • • • • ••• •. • fasteners with Dekfast IF -2 -SB, Dekfast Galvalume Steel Round 2-3/8" 20 ga. • • Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates or Soprafix 2-3/8"—SB Stress Plates, spaced maximum 12" o.c. through the side laps and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -165 psf. See General Limitation #7.) MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 148 of 160 Fastening #2: Mechanically attach base sheet with Soprema #14 or Soprema #15 fasteners and Soprema Soprafix 2" SB Stress plates, Dekfast 14 or Dekfast 15 HS fasteners with Dekfast IF -2 -SB, Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates or Soprafix 2-3/8" —SB Stress Plates, spaced maximum 12" o.c. through the minimum 3" wide side lap and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -150 psf. See General Limitation #7.) Ply Sheet: Elastophene 180 PS, Colphene 180 PS, Sopralene 180 PS 2.2, Elastophene PS, Elastophene PS 3.0, adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. with minimum 3" wide side lap. Membrane: Elastophene Flam FR GR, Elastophene Flam GR, Elastophene Flam LS FR GR, Sopralast 50 TV AIu, Soprastar Flam, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralene Flam Antirock, torch -applied with minimum 3" wide side lap. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. •... Apply any coating listed in Table 4 above, or any Miami -Dade approved coating • • • •. system. • •• • • •• • . • • .• • Maximum Design Pressure: See Fastening Options Above MIAMIOADE COUNTY APPROVED • •••• •• • • . . • .••• • •• • • •• •• • • . • • • • • . . •. • • • .• . . •• .. • • ••. • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 149 of 160 • • • • • • Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Min. 2500 psi concrete or concrete plank System Type D(14): All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Sopra-ISO s, ISO 95+ GL, H -Shield, ENRGY 3, Ultra -Max, M -Shield, Sopra-ISO r Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK Gypsum -Fiber Roof Board, DensDeck, DensDeck Prime Minimum 0.5" thick 1, 2, 13, 14 or 24 1:4 ft2 Note: Insulation layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no amnion greater than 8 ft. All layers of insulation and base sheet shall be simultaneously • %astennd. Seebase(anchor sheet below for fasteners and density. Refer to Rooting Application . • Standard R35117 for insulation attachment. • 1'i'imc'r: Coverboard is primed with an approved ASTM D41 asphalt primer at a rate of 100- . (dp �ional) 150 ft2/gal. •••• ••• • • •Base Sheet:'.... • One layer of Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, • . Sopralene 250 SP, Soprafix [F]*, Soprafix Base 613*, Soprafix [S]*, Soprafix Base • • • • ▪ • • • • 612*, Soprafix [X]*, Soprafix Base 614*, Soprafix*, Soprafix Base 622*, Soprafix- • • • . e, Soprafix Base 641, Soprafix Base 610**, Soprafix Base 611**, Soprafix Base • '• 630** fastened as specified below: • • . • •••• • • • *Requires torch -applied cap membrane. ** For use only when using 2 in. diameter plates and requires torch -applied cap membrane. Fastening #1: Torch -applied base sheet to coverboard with minimum 3" wide side lap. Mechanically attach base sheet with Soprema #14 fasteners or Soprema #15 fasteners Soprema Soprafix 2" SB Stress Plates or Soprafix 2-3/8 in. SB Stress Plates, Dekfast 14 or Dekfast 15 HS fasteners with Dekfast IF -2 -SB, Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates spaced maximum 12" o.c. through the side laps and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -165 psf. See General Limitation #7.) MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 150 of 160 Fastening #2: Mechanically attach base sheet with Soprema #14 fasteners or Soprema #15 fasteners Soprema Soprafix 2" SB Stress Plates or Soprafix 2-3/8 in. SB Stress Plates, Dekfast 14 or Dekfast 15 HS fasteners with Dekfast IF -2 -SB, Dekfast Galvalume Steel Round 2-3/8" 20 ga. Barbed plates, Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Stress Plates or Trufast 2.4" Barbed Seam Plates, Soprema #15 HD Fasteners with Soprema 2" Seam Plates spaced maximum 12" o.c. through the minimum 3" wide side lap and two equally spaced staggered rows in the field of the membrane. (Maximum Design Pressures -150 psf. See General Limitation #7.) Ply Sheet: Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied with minimum 3" wide side lap. Membrane: Surfacing: Or Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene HS, Elastophene HS 62, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Sopralene 180 Sanded, Sopralene 250 Sanded, or 1-2 plies of Sopra IV or Sopra VI, adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. with minimum 3" wide side lap. Elastophene GR, Elastophene FR GR, Elastophene GR, Elastophene LS FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Soprastar Sanded, Sopralast 50 TV Alu • • • • Sanded adhered in full mopping of approved asphalt applied within th6 EVT range' • and at a rate of 20-40 lbs./sq. with minimum 3" wide side lap. ' • • • • " • •• Surfacing is Optional on granular surfaced field cap membranes. • • Surfacing is Required for smooth or sanded surfaced field cap membranes. • • • Refer to Underwriters Laboratories or Intertek Testing Services listings for • ' • applicable fire classifications• •• • . • • Apply any coating listed in Table 4 above, or any Miami -Dade appfoldt1 coating • . • . • • system. Maximum Design Pressure: See Fastening Options Above MIAMI4 ADE COUNTY APPROVED • • • • • •• • • ••• • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 151 of 160 • • . •..... • • • • • • • • • • Membrane Type: Deck Type 3: Deck Description: System Type F(1): SBS Concrete Decks, Non -Insulated 2500 psi structural concrete or concrete plank Base sheet adhered to primed substrate. All General and System Limitations apply. Primer: (Optional) Base Sheet: (Optional) Ply Sheet: • .•• • • •••. • • • • • • • • • • •• • • • •• • • • • • •• •• • • • • • •• • • • • •• •••. •••• • • •• •• • • • • • • ••• • .. • Membrane: • • • • MIAMI.DADE COUNTY APPROVED Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., to top surface of any base or ply sheet prior to application of next layer One layer of Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive or COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square or in hot asphalt at 25 lbs./sq. *Requires torch -applied ply or cap membrane. Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive or COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square or in hot asphalt at 25 lbs./sq. Or Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, torch -applied. *Requires torch -applied cap membrane. Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in COLPLY Adhesive or COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square or in hot asphalt at 25 lbs./sq. to sand surfaced ply membrane. Or Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 152 of 160 Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -82.5 psf. (See General Limitation #9.) • • • • •• • • •••• • • •••• • • •. • • • • • • • • •• •• • ••. • • • .••• •• • •. • • •• •• • •.• • •• • • • • • •• •• ••• • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 153 of 160 Membrane Type: Deck Type 3: Deck Description: System Type F(2): SBS Concrete Decks, Non -insulated 2500 psi structural concrete or concrete plank Base sheet torch -applied to primed deck. All General and System Limitations apply. Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of base sheet. Base Sheet: Ply Sheet: (Optional) • • •••• • •• • • •• •• •• Membrane: • •• •••• •• •• • • ••• •• •••• • • •• • • • • •• • • • •• •• • • • •• •• • • • • • • • • • ••• • • •• Surfacing: • • •• • • • .• Maximum Design Pressure: MIAMFDADE COUNTY APPROVED One ply of Colvent TG, Colvent 180 TG, Colvent Flam TG*, Colvent Flam 180 TG*, torch -applied. *Requires torch -applied ply or cap membrane. One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250* or Sopralene 250 SP, torch -applied. Or One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elastophene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base or ply membrane. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -187.5 psf. (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 154 of 160 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(3): Base sheet adhered to primed substrate. All General and System Limitations apply. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq., (Optional) to top surface of any base or ply sheet prior to application of next layer Base Sheet: One layer of Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene (Optional) Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square or in hot asphalt at 25 lbs./sq. Requires torch -applied ply or cap membrane. Ply Sheet: Elastophene Sanded, Colphene Sanded, Elastophene Sanded 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Soprabase, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene 250 Sanded, adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square FOR hot asphalt at 25 lbs./sq. "' • O r • . • • . . • Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam.1j§:, lastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, $ppralene Ram • • 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 1$0SB 3.5, % • • Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene I+kaio it0*, • • • Membrane: Sopralene 250 SP, torch -applied. *Requires torch -applied cap membrane. • • • • • Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, lasseghene FR+ GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR CR, Sopralene • 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sopralast 50 TV Alu Sanded adhered in COLPLY Adhesive, COLPLY Modified Adhesive at 1.5 — 2.0 gallons/square or in hot asphalt at 25 lbs./sq. to sand surfaced ply membrane Or Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 155 of 160 • • • • . Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design Pressure: -187.5 psf. (See General Limitation #9.) •••• • . • •••• •. • • • •• • •• . • •• • . • • •• • • • • .• • . • . • •• •••• •• • • • •• • • . • • • ••• •• • • • • • ••• • • •• •• • • • . • • •• • . • •• MIAMI-DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 156 of 160 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(4): Membranes adhered to primed substrate. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero at an application rate of 100 ft2/gallon. Base Sheet: One layer of Colvent SA, Elastophene Stick, Sopralene Stick or Colphene Stick, self -adhered. Or One layer of Colvent TG or Colvent 180 TG, torch -applied. Ply Sheet: One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded (Optional) 2.2, Elastophene Sanded 3.0, Elastophene HS, Elastophene HS 62, Elastophene 180 Sanded, Colphene 180 Sanded, Soprabase, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded, adhered in hot asphalt at 25 lbs./sq. to sand surfaced base membrane. ..•. • Primer: Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at «rap gf 1 galYSct' (Optional) to top surface of any base or ply sheet prior to application of next fay& . ' . •• •• Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Elasiophene FR+• GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR Gii,• Sopraltr• • . 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR Gid; Oklphene 250' • FR GR, Sopralene 250 FR+ GR, Sopralene 250 Ultra FR GR, Sap¢t 50 Tv' • Alu Sanded adhered in hot asphalt at 25 lbs./sq. to sand surfaced bas'e'or ply • • • membrane. . • • • • • Surfacing: • • • • • • Surfacing is Optional on granular surfaced field cap membranes.: • • . • • Surfacing is Required for smooth or sanded surfaced field cap meffbraties. " • • • • •• Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Maximum Design -242.5 psf. With Self -Adhered Base Sheet (See General Limitation #9.) Pressure: -267.5 psf. With Torch -Applied Base Sheet (See General Limitation #9.) MIAMFDADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 157 of 160 Membrane Type: Deck Type 3: Deck Description: System Type F(5): SBS Concrete Decks, Non -Insulated 2500 psi structural concrete or concrete plank Membranes adhered to primed substrate. All General and System Limitations apply. Substrate Preparation: Primer: Base Sheet: Ply Sheet: (Optional) •.•. • • Printf: • • • • • • •• (optional) • S e cane• •••• .. •'•• • • • •• •• •• • • . • • ••• • • •Surfacing: • • •. •• • • • • • • • •• . • • •• Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500, Elastocol Stick, Elastocol Stick Zero at an application rate of 100 ft2/gallon. One layer of Colvent SA, Elastophene Flam Stick or Sopralene Flam Stick, self - adhered Or One layer of Colvent TG, Colvent 180 TG, Colvent Flam TG, Colvent Flam 180 TG, torch -applied. One or more layers of Elastophene Flam, Elastophene Flam 2.2, Elastophene Flam HS, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180*, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Soprafix, Soprafix Base 622, Sopralene Flam 250, Sopralene 250 SP, torch -applied. Elastocol 500, Elastocol Stick, Elastocol Stick Zero applied at a rate of 1 gal./sq. to top surface of any base or ply sheet prior to application of next layer Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. -272.5 psf. With Self -Adhered Base Sheet (See General Limitation #9.) -295 psf. With Torch -Applied Base Sheet (See General Limitation #9.) NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 158 of 160 4 Membrane Type: SBS Deck Type 3I: Concrete Decks, Non -Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(6): Non -Insulated, Roof cover to concrete All General and System Limitations apply. Primer: ASTM D41 or Elastocol 500 primer applied at a rate of 0.75 gal./sq. Base Sheet: Elastophene Flam HS, Elastophene Flam 2.2, Elastophene Flam, Sopralene Flam 180, Colphene Flam 180 or Sopralene Flam 250, torch -applied. Ply Sheet: Elastophene Flam HS, Elastophene Flam 2.2, Elastophene Flam, Sopralene Flam (Optional) 180, Colphene Flam 180 or Sopralene Flam 250, torch -applied. Membrane: Soprastar Flam, Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Soprafix Cap FR 651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. Surfacing: Surfacing is Optional on granular surfaced field cap membranes. Surfacing is Required for smooth or sanded surfaced field cap membranes. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications ••••• Apply any coating listed in Table 4 above, or any Miami -Dade r ppgNed coating' system. • • • :' • • • • •• Maximum Design • Pressure: MIAMI.DADE COUNTY APPROVED -367.5 psf. (See General Limitation #9.) •••• • • • • •• •• • • • • • • • • •• • • •• • • • • • •• • • •• • • •• •• • • • • •'• • • • • • • • • • • • ••• • • • NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 159 of 160 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shallibe performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control'Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. 4astener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 1�f�, tested im coi ipliance with Testing Application Standard TAS 105. If the fastener value, as field- . d:are b 1pr. .5 lbf. insulation attachment shall not be acceptable. • • 6. Fastener spag4„ fox mechanical attachment of anchor/base sheet or membrane attachment is based on a • • .mininum fasten; resistance value in conjunction with the maximum design value listed within a specific . •system. Should the fastener resistance be less than that required, as determined by the Building Official, a :reyiSe41 fasts ,petting, prepared, signed and sealed by a Florida registered Professional Engineer, • •Re lstered Aithitett, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall • • utilize the mlfitflital resistance value taken from Testing Application Standards TAS 105 and calculations . • hf ee tnpliance with' Roofing Application Standard RAS 117. • 7.. Pe i eter aid• cener areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 15-0709.14 Expiration Date: 03/01/21 Approval Date: 03/17/16 Page 160 of 160 .j MIAMI•QADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOU BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) SOPREMA, Inc. 310 Quadra) Drive Wadsworth, OH 44281 SCOPE: This NOA is being issued under the applicable rules and regulations governing the us materials. The documentation submitted has been reviewed and accepted by Miami -Dade Product Control Section to be used in Miami Dade County and other areas where allowed by Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it •"'. is determined by Miami -Dade County Product Control Section that this product or msteri.ael:fails to • meet the requirements of the applicable building code. .•• • MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 6)315-2590 F (786) 31525-99 iamidade. ' ov/economv • . • •• .• This product is approved as described herein, and has been designed to comply with tliehirida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. . • • • • . : • .' . . . • .• • ROOFING SYSTEM APPROVAL Category: Sub -Category: Material: Deck Type: Maximum Design Pressure: Roofing Waterproofing Systems SBS Concrete, Steel, Lightweight Concrete -572.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D6163 Product Dimensions Colvent TG 39" x 49' (1.5 sq.) Colvent 180 TG 39" x 33' (1 sq.) ASTM D6164 Colvent Flam TG 39" x 49' (1'/2 sq.) ASTM D6163 .... • • Cglveit.Flam 18(.• .'3• 9" x 33' (1 sq.) ASTM D6164 • • .• • • • Cdident'SA . • • • ••• •• • •••• • • • • •'39" x 49' (1.5 sq.) ASTM D6163 El4stopl}ene ; • :9" x 49' (1'/2 sq.) ASTM D6163 • SafidBd; . •• • • • • ••• •• •• doilPhene Sanded 39" x 49' (1'/2 sq.) ASTM D6163 Elastophene 39" x 33' (lsq.) ASTM D6163 Sanded 3.0 Elastophene PS 39" x 49' (11/2 sq.) ASTM D6163 Elastophene PS 3.0 39" x 49' (1'/2 sq.) ASTM D6163 Product Description Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. Non -woven polyester reinforced, modified bitumen membrane with 1" wide factory applied heat weldable strips on back side. Fiberglass reinforced, modified bitumen membrane with a burn -off film underside and a plastic film surface. Non -woven polyester reinforced modified bitumen membrane with a burn -off film underside and a plastic film surface. Applied by heat welding. Fiberglass reinforced, modified bitumen membrane with 1" wide factory applied self - adhering strips on back side Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripped. Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. Glass reinforced modified bitumen membrane with a plastic burn -off film for heat weld bonding to the top side. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 2 of 74 TRADE NAMES Product Elastophene SP 2.2 OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Specification Description ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). ASTM D6163 Glass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). ASTM D6163 Fiberglass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding. ASTM D6163 Fiberglass reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by kieat welding. • ASTM D6163 Dimensions 39" x 49' (11/4 sq.) Colphene SP 2.2 39" x 49' (1'/2 sq.) Elastophene SP 3.0 Colphene SP 3.0 Elastophene Flam 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) Elastophene Flam 39" x 49' (1'/2 sq.) 2.2 Sopralene 180 Sanded 2.2 Elastophene 180 Sanded Colphene 180 Sanded Sopralene 180 PS Elastophene 180 PS MIAM I:ADECOUNTY APPROVED 39" x 49' (11/4 sq.) 39"x49'(1'/2sq.) 39" x 49' (11/4 sq.) 39" x 33' (1 sq.) 39" x 48' (11/4 sq.) .... Fiberglass reinforced modifiedbituinen ••• • • • membrane covered on both s'idllldVlth a ptastlt• burn -off film. Applied by head welding. ASTM D6163 Fiberglass reinforced modifiedbitamen • • • • • membrane covered on both 4,iik5,14th a plastic • burn -off film. Applied by h a weltling. ••••••• ASTM D6164 Non -woven polyester reinfoioed•modified • bitumen membrane sanded on bothhsides.• • Applied in hot asphalt, cold :tdhcsiye or rthbon ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 stripping. • • • • • • •• • Non -woven polyester reinforced modified • • • bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the top and sanded on the bottom. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 3 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D6164 Product Sopralene 180 PS 2.2 Colphene 180 PS Elastophene LS FR GR Elastophene GR Elastophene FI, CA . .. • • • Eltlstophene 39" x 33' (1 sq.) Dimensions 39" x 33' (1 sq.) 39" x 48' (11/2 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) • • • • • • •• FlathLS FRGR'••• • •• •••• • • • • ••• • •••• PletQphene • ..• • •39" x 33' (1 sq.) Flamm GR • • •• •• • • • • Platt phene • • •• • • 39" x 33' (1 sq.) Flam FR GR Elastophene 39" x 33' (1 sq.) Flam FR+ GR Sopralene 180 39" x 33' (1 sq.) Sanded 39" x 26' (3/4 sq.) Sopralene 250 39" x 33' (1 sq.) Sanded 39" x 26' (3/4 sq.) MIAMI•DADE COUNTY APPROVED ASTM D6164 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the top and sanded on the bottom. Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and a plastic burn -off film on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, sanded on the bottom and mineral granules on the top. Applied in hot asphalt, cold adhesive or ribbon stripping. Fiberglass reinforced modified bitumen membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Fiberglass reinforced modified bitumen membrane with fire retardants, a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Fiberglass reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Non -woven polyester reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 4 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Sopralene 180 SP 3.5 Colphene 180 SP 3.5 Sopralene 180 SP 3.0 Sopralene 250 SP Soprafix Soprafix Base 622 Soprafix Cap FR -651 Sopralene Flam 180 Colphene Flam 180 Sopralene Flam 250 MIAMI•DADE COUNTY APPROVED Dimensions 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39"x33'(1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) 39" x 33' (1 sq.) TABLE Test Specification ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D6164 1 dt DescriptiProucon Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied by heat welding. Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and sanded on the top. Applied:1by heat welding. •• .' Non -woven polyester reinforceomodified. • • bitumen membrane sanded ortbetrgides. • • • Non -woven polyester reinforeartitbtiifred . bitumen membrane sanded on 6Eth`sides. • • . `. • Fiberglass reinforced modified'iWmen `• membrane with fire retardants 04 plastie p}rii}; off film on the bottom and mipggq,ligranules orl the top. Applied in cold adhesive o$by heat welding. Non -woven polyester reinforceOSBS modtRecl : bitumen membrane, both sides covered with a •. plastic burn -off film, used as a base/ply. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced SBS modified bitumen membrane, both sides covered with a plastic burn -off film, used as a base/ply. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced SBS modified bitumen membrane, both sides covered with a plastic burn -off film. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 5 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D6164 Product Sopralene 180 FRGR Colphene 180 FRGR Sopralene 250 FRGR C2lpJi ne 250 p3 -,G13,'• • • • • •• • • • •• • • • •• • Dimensions 39" x 33' (1 sq.) 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) • •• •••• • • Shciralene ••'• 39" x 33' (1 sq.) Matn 180 GR• • •• •• •• •• • • • • • • • • • • • Cole : • • • • 39" x 33' (1 sq.) hull 180 GR Sopralene Flam 180 FRGR Colphene Flam 180 FRGR ASTM D6164 ASTM D6164 ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 Product Description Non -woven polyester reinforced modified bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants and a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn - off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants and a sanded bottom and a mineral granules top. Applied in hot asphalt, cold applied adhesive or ribbon stripping (after removal of plastic burn - off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants and a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 6 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification ASTM D6164 Product Sopralene Flam 250 FR GR Dimensions 39" x 33' (1 sq.) Colphene Flam 39" x 33' (1 sq.) ASTM D6164 250 FR GR Sopralene Flam 180 FR+ GR Sopralene Flam 250 FR+ GR Soprastar Flam Soprastar Stick Sopralene Stick Colphene Stick Sopralene Flam Antirock Sopralene Flam Stick Elastophene Stick FR GR MIAMI-DADE COUNTY APPROVED 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6162 39" x 33' (1 sq.) ASTM D6163 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6163 Product Description Non -woven polyester reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants and a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn - off film). Non -woven polyester reinforced modified bitumen membrane with fire retardants a plastic burn -off film on the bottom and mineral granules on the top. Applied by heat welding or ribbon stripping (after removal of plastic burn -off film). Non -woven polyester reinforced modified •••• bitumen membrane with fire retardants a plastic • burn -off film on the bottom andkrnir eral gaatillas. on the top. Applied by heat welding or ribeon• • stripping (after removal of pl tStir•bdrn-off filrft). Polyester reinforced SBS modi4Ted'bitumell'. •. membrane with a plastic burn-otif lm on tie • • bottom side and a reflective villins lop surfaii• : Applied by heat welding. • Fiberglass reinforced SBS mddifilyd::bitumen . membrane with a release film.covored self adhering bottom side and a reflective white leg surface. • • Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Self -adhered, polyester reinforced membrane with a release film on the bottom and a sanded top. Non -woven polyester reinforced modified bitumen membrane with a sanded underside and surfaced with colored granules. Self -adhered, polyester reinforced membrane with a release film on the bottom and a plastic burn -off film on the top. Self -adhered, fire -rated, granule surfaced, fiberglass reinforced membranes. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 7 of 74 TRADE NAMES OF PRODUCTS MANUFACTU TABLE Test Product Dimensions Specification Sopra G 39" x 108' ASTM D4601 (3.5 sq.) Modified Sopra G Soprabase Soprabase S Soprabase TG Elastophene HS •••• • • • •• &opra;v • • •• •• • • •• • 39" x 108' (3.5 sq.) 39" x 99' (3 sq.) 39" x 65' (2 sq.) 36" x 65' (2 sq.) 39" x 66' (2 sq.) • • • • • • • • "6" x 180' (5 sq.) ASTM D2178 • •••• • • •••• ASTM D4601 ASTM D4601 ASTM D4601 ASTM D4601 ASTM D6163 iop':••••••36" x 180' (5 sq.) ASTM D2178 • • • • • • • • E1aa.9tephene PIIS • • 39" x 33' (1 sq.) ASTM D6163 Soprastar Sanded 39" x 33' (1 sq.) ASTM D6162 39" x 33' (1 sq.) ASTM D6164 39" x 33' (1 sq.) ASTM D6164 various ASTM D41 Sopralene Flam 180 GR 3.5 Sopralene Flam 180 FR GR 3.5 Elastocol 500 Elastocol Stick various Proprietary ALSAN FlashingTM 1.25 gallon pail or Proprietary 3.75 gallon pail MIAMI-DADE COUNTY APPROVED RED OR LABELED BY APPLICANT: 1 Product Description Fiberglass reinforced oxidized asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Fiberglass reinforced modified asphalt base sheet for bonding or mechanically attaching to substrate. For use as a base/ply sheet only. Oxidized asphalt, polyester reinforced, sand - surface base sheet. For use as a base/ply sheet only. SBS modified bitumen, polyester reinforced, sand -surfaced base sheet. For use as a base/ply sheet only. SBS modified bitumen, polyester reinforced, sand -surfaced base sheet. For use as a base/ply sheet only. Fiberglass reinforced modified bitumen membrane with fire retardants and sanded on both sides. Applied in hot asphalt, cold adhesive or ribbon stripping. Type IV, fiberglass reinforced, smooth surfaced ply sheet used in multi -ply systems and complies with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Type IV, fiberglass reinforced, smooth surfaced ply sheet used in multi -ply systems and complies with ASTM and UL Standards. Applied in hot asphalt or cold adhesive. Fiberglass reinforced modified bitumen membrane sanded on both sides. Applied in hot asphalt or cold adhesive. Polyester reinforced SBS modified bitumen membrane with a highly reflective reinforcement film on top and sanded on the bottom. Non -woven polyester reinforced modified bitumen membrane with colored granules on top and film on the bottom. Non -woven polyester reinforced modified bitumen membrane with colored granules on top and film on the bottom. Asphalt primer. Polymer based primer. One part polyurethane/bitumen resin, moisture cure compound for use as a flashing component. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 8 of 74 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Specification Proprietary Product Soprawalk Sopradrain Eco -Vent WR Sopradrain Eco -2 WR Sopramastic SP -1 High Velocity® Membrane Adhesive II (HVMA-II) Duotack FM Adhesive FM Adhesive (VOC) COLPLY Adhesive COLPLY Modified Adhesive Soprastar Adhesive MIAMI-DADE COUNTY APPROVED Dimensions 39" x 26' (3/4 sq.) 5 gallon pail, 55 gallon 1500 ml cartridges 5 gallon pail, 55 gallon 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail or 55 gallon drum 5 gallon pail, 55 gallon drum or 350 gallon tote 5 gallon pail, 55 gallon drum or 350 gallon tote Proprietary Proprietary ASTM C920, Type S, Grade NS, Class 50 Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Product Description Non -woven polyester reinforced modified bitumen membrane with a sanded bottom and mineral granules on the top. Applied by hot asphalt, cold adhesive or ribbon stripping. Polypropylene roof drain. Polypropylene roof drain. A solvent free sealant. Two part elastomeric urethane adhesive. Two part elastomeric urethane foam adhesive. .... Elastomeric bitumen based ccld tdl3esive.. . . . ••. .. . Elastomeric bitumen based co cl adhesive: • ..• . . .. .. • • • . . .. • .. Polymer modified cold proasVitnibrane adhesive. Elastomeric bitumen based cddadhesive... . . •• Proprietary Elastomeric bitumen based cold adhesive. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 9 of 74 • APPROVED INSULATIONS: Product Name STYROFOAM High Load 60 Insulation STYROFOAMTM PLAZAMATETM SECUROCK Gypsum -Fiber Roof Board Ultra -Max Sopra-ISO x, Sopra-ISO r, Sopra-ISO s M -Shield Sopraboard ACoam-II ISI5.4 + GL H-Sjiield • . • • • • 41. Densi: ckDensUeck Prime , •• • 41... • . • • • • • 00 .. 110 . 41 • • • • • • • • • • • • • 4100 • 00 00 MIAMFDADE COUNTY APPROVED TABLE 2 Product Description Extruded Polystyrene Insulation, Type VII Extruded Polystyrene Insulation, Type VII Gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Mineral fortified asphaltic cored coverboard Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Manufacturer (With Current NOA) The Dow Chemical Co. The Dow Chemical Co. USG Corp. RMax Operating, LLC SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. Atlas Roofing Corporation Firestone Building Products Company, LLC Hunter Panels LLC Georgia Pacific Gypsum LLC NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 10 of 74 APPROVED FASTENERS: Fastener Number Product Name 1. SOPREMA #14 Fasteners 2. SOPREMA #14 MP Fastener 3. SOPREMA #15 HD Fastener 4. SOPREMA 2" Seam Plate 5. SOPREMA 2.4" Seam Plate 6. SOPREMA 3" Round Insulation Plate 7. SOPREMA 1.7 in. Base Sheet Fastener 8. CR Base Sheet Fastener (1.2" or 1.7") 9. OMG Heavy Duty 10. OMG 3" Galvalume Steel Plates 11. Dekfast Galvalume Steel Hex Plates 12. Dekfast Galvalume Steel 3" Round plates 13. Dekfast 14 14. FM -90 15. Trufast 3" Metal Insulation Plates 16. Trufast #14 Stainless Steel HD Fasteners 17. Trufast #14 HD Fastener 18. Trufast #15 EHD Fastener 19. Trufast 2" Barbed Metal Seam Plate 20. Trufast 2.4" Barbed Metal Seam Plate MIAM4DADE COUNTY APPROVED TABLE 3 Product Description Fasteners for membrane or insulation attachment to wood, steel or concrete decks. Insulation fastener for wood, steel and concrete. Insulation and membrane fasteners Stress plate Galvalume steel stress plate Stress plate Base ply fastening systems for lightweight concrete decks Galvanized fastener for base sheet attachment for gypsum and lightweight concrete. Insulation fastener for wood, steel and concrete. Galvalume stress plate. Galvalume steel plate Galvalume steel plate. Insulation fastener Base ply fastening systems for lightweight concrete decks Galvalume steel plate Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Insulation fastener for wood, steel and concrete. Stress plate Galvalume steel stress plate Dimensions Various Various Various 2" diameter 2.4" Round 3" diameter 2.7" head x 1.7" long 1.125" thick • • • Various Manufacturer (With Current NOA) SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. SOPREMA, Inc. OM¢'IM.. • •••• •• • •• • •• • •• • • •• • •• 3" round• •• 2'/s" x 3 ' i`• • •• • OMG, V. •• • • • • • •• • •• OMG% Inc.. • • • • ••• ••• •• : •SFS Intec'Inc. • • • 3" round • •,SFS Intec, Inc. •• • ••• • Various 2.7" head x 1.7" long 3" round Various Various Various 2" diameter 2.4" Round • SFS Intec•Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. Altenloh, Brinck & Co. U.S., Inc. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 11 of 74 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Manufacturer Application System Number 1. 2. 3. Generic Generic SOPREMA, Inc. 4. Karnak Corporation 5. SOPREMA, Inc. 6. Thermo Manufacturing Systems, LLC 7. Quest Construction Products LLC dba United Coatings ."8!. Insulating Coatings •••. • .• • . . •• • • • •• • . • ••TO. • ornoration He m Company Iipp'al Coating Corp. Gebefit Gravel applied at 401bs.bs/sq., adhered with flood coat of asphalt at 60 lbs./sq. Slag applied at 300 lbs./sq., adhered with flood coat of asphalt at 60 lbs./sq. Gravel applied at 400 lbs./sq., adhered with COLPLY Adhesive, FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 4 gal./sq. Karnak #97 Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal./sq. Cural Aluminizer applied at an application rate of 2 gal./sq. Super Prep Roof Coating applied in two coats at an application rate of 1.5 gal./sq./coat. Roof Mate Coating, applied in one base coat at a rate of 1.5 gal./sq., and one finish coat at a rate of 1.5 gal./sq. Astec 2000 Finish Coat applied in two base coats at a rate of 0.75 gal./sq./coat and two finish coats at a rate of 0.75 gal./sq./coat. HE280DC White Elastomeric Roof Coating applied in two coats at an application rate of 1 gal./sq./coat. Acryshield® A500 applied in two coats at an application rate of 1 gal./sq./coat. Semi -ceramic coated colored granules. Ti:1144 NAMES dF PRODUCTS MANUFACTURED BY OTHERS: .• • • ••• •• •• •• • • Product Exterior Ceramic Tiles Portland Cement Concrete Pavers Wausau Lok -Down Paver Lok -Down Tab Terra Stand Pedestal MIAMI.DADE COUNTY APPROVED Dimensions Test Specification 12" x 12" x '/2" ASTM C56 & ANSI A137.1 Various 12" x 12" x 1" 24" x 24" x 2" Base: 6.5" square plate Top: 5.8" square plate 5" round core ANSIA118.1 ASTM C936 ASTM C936 Proprietary Product Description Ceramic plaza deck walking tiles, 5% water absorption max. A thin -set Portland based mortar formulated for ceramic tile installation. high density concrete pavers 8000 psi Min. Compressive strength, 5% water absorption SBR rubber tab used to support pavers to stand. Proprietary Copolymer polypropylene stand. Manufacturer Generic Generic Generic Wausau Tile, Inc. Wausau Tile, Inc. Wausau Tile, Inc. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 12 of 74 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories, Inc. Dynatech Engineering Corp. Exterior Research & Design, LLC Trinity I ERD MIAMI•DADE COUNTY APPROVED Test Name/Report FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4454 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 UL 790 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM D6163 Physical Properties ASTM D4798 & TAS 110 ASTM D6164 ASTM D2178 ASTM D4601 ASTM D6163 ASTM D6162 ASTM D6163 ASTM D2178 ASTM D4601 ASTM D6163 ASTM D6164 ASTM D6164 Test Identifier Date 1W8A1.AM 07/15/93 1Z3A6.AM 04/27/95 2DOAO.AM 08/15/97 2B8A4. AM 07/02/97 1D7A4.AM 11/09/98 3026028 05/25/06 3028631 08/09/07 3029098 10/25/07 , 3025185 05/22/07 3017614 02/27/06 3023749 09/28/06 3022038 04/05/06 3045101 11/05/12 3002351 02/28/03 797-07582-267 08/15/12 797-03385-267 11/05/12 RR201064 05/01/15 3044801 02/27/12 3049322 01/17/14 3045734 04/04./i I. • 302459405/19166, R11436 06/1'8/15•• • 10.94.27 .... 10/37/94. 2491-04.95 e••••• 01/44/! .• • • 2003.02.97-1 •••.,• 02/1'$fP7.; 2003-2.04.97-1 04/15/97 2002.07.97-1 : • : 08/1.5/97. 2755.09.02 : • • • 10/189/02 2761.09.03 • • • 09/V/ 2761.10.03-2 10/03/03' • 2760.12.04-R1 12/23/04 2777.09.05-R2 04/18/07 S6740.11.07 11/02/07 S10950.04.10 04/06/10 511440.06.10 06/01/10 S11440.01.11 -R1 06/07/12 S11440.11.10-4 11/17/10 S11440.11.10 -3-R2 08/26/14 S11440.12.10 -1-R1 06/07/ 12 532700.12.10-R2 07/07/14 S35860.09.12 -R1 03/14/13 S35860.12.11-1 12/12/11 S35860.12.11-2 12/12/11 S35860.05.12 -1-R2 03/14/13 S35860.05.12 -2-R2 03/14/13 S35860.05.12 -3-R1 03/14/13 NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 13 of 74 Test Agency Test Name/Report Test Identifier Date Trinity I ERD TAS 114 S35010.10.10 -R1 08/26/14 TAS 114 547170.08.14-1 08/25/14 TAS 114 S47300.08.14-1 08/19/14 TAS 114 S47300.08.14-2 08/19/14 TAS 114 SC5190.08.14 08/19/14 ASTM D6163 543400.08.14-4 08/26/14 ASTM D6163 S43400.08.14-5 08/26/14 ASTM D6164 S43400.08.14-6 08/26/14 ASTM D6164 S43400.08.14-7 08/26/14 ASTM D6164 S43400.09.14-9 09/02/14 Physical Properties S45890.09.14 09/02/14 ASTM D6164 S44110.08.14-5 08/29/14 ASTM D6164 535860.05.12-2-R3 08/29/14 ASTM D6506 S45010.02.14 02/07/14 ASTM D6162 S32700.12.10 -R2 07/07/14 ASTM D6164 544220.09.14-7C 09/02/14 ASTM D6164 S44110.01.15 -4A -R3 05/01/15 TAS 117 (B) S32840.06.10 -R1 12/11/14 IRT of S. Florida, Inc. TAS 114 01-002 01/21/01 ITSI,Warnock Hersey ASTM D5147 05/27/93 PRIVOnstructionMaterials ASTM D1644/D2196 SOP -049-02-01 05/31/12 • • Teitmlogies, tit. ASTM D4601 SOP -043-02-01 02/27/12 • ASTM D4601 SOP -042-02-01 02/27/12 • • • •• •••• ASTM D2178 SOP -041-02-01 02/27/12 •..• • •....• ASTM D2178 SOP -040-02-01 02/27/12 • • • • TAS -138 SOP -010-02-01.03 07/26/11 • • • • • • • • ASTM D3019 SOP -050-02-01 03/04/13 • • • • • Physical Properties ADCO-001-02-01 06/16/13 • • • Atlantic:& CaribbearrRoof TAS 114 ACRC# 08-0359 06/20/08 • • Cpnedki'ng • • • Irfttrtek 1 Architectrural Testing Physical Properties F0856.01-106-18 05/13/16 MIAMI DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 14 of 74 APPROVED APPLICATIONS: Membrane Type: Deck Type 3I: Deck Description: System Type A(1): All General and System Substrate Preparation: Primer: Base/Ply Sheet: Membrane SBS Concrete, Insulated Terrace/Plaza Deck, Planter, Traffic Membrane adhered directly to primed concrete deck. Insulation adhered under surfacing for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primed with ASTM D 41 primer applied to top of composite board or top of cover board in insulation assembly. One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene I I M •. 250 FR+ GR, torch -applied.• • "" .. . .. • Integrity Test: Required, and shall be performed in accordance with ASTJRS957 14 aft.. • approved lab. Water maybe maintained for a period longe: than.24 hours if. required. One or more layers of any of the following insulations. Insulation Layer .... . . •. • . . • • .• Insulation Fastener• • ..• Faster . (Table 3) Density/f12 STYROFOAM High Load 60 Insulation, STYROFOAMTM PLAZAMATETM Minimum 1.5" thick N/A . • Note: All layers of insulation shall be adhered with Duotack adhesive beads spaced L! o.c.ileare refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation as the final membrane substrate. Inspection: Surfacing: Maximum Design Pressure: MIAMI.DADE COUNTY APPROVED Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards and traffic surfacing. All defects observed shall be corrected. Exterior grade ceramic plaza deck walking tiles (Minimum size of 12" x 12" and minimum '/2" thickness) tiles shall be embedded into mud -set Portland Cement applied with a'/4" minimum square notched trowel. Tiles should then be carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. -255 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 15 of 74 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: Terrace/Plaza Deck, Planter, Traffic System Type A(2): Concrete Paver Finish over Membrane. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, Preparation: and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Elastocol 500, Elastocol Stick or ASTM D 41 primer applied to deck at a rate of 100-150 ft' -/gal. Base Sheet: One or more plies of Sopralene Flam 180, Colphene Flam 180 or Sopralene Flam 250, torch -applied according to manufacturer's application instruction. Membrane: Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Soprastar Flam torch -applied according to manufacturer's application instruction. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an •••• approved lab. Water maybe maintained for a period longer than 24 hours if ' • • • required. • •• • • . • l �pec,Sion: : Contractor and a representative of the membrane manufacturer shall inspect the •• • waterproofing assembly and notify the contractor of any defects. Inspection • •must take place prior to installation of any overlay insulation, protection pads, •.. • • •• • •... • drainage boards and traffic surfacing. All defects observed shall be corrected. • • nsplAtion UM •' Insulation Fasteners Fastener • (Table 3) Density/ftz •. STVROFOAVI:I•Iiph Load 60 Insulation, STYROFOAMTM PLAZAMATETM M nfm3Im 1.5; thick N/A N/A • • • • • $ote"All layers of insulation shall be adhered with Duotack adhesive beads spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation as the final membrane substrate. Surfacing: Concrete pavers (24" x 24" x 1.5" thick), 4000 psi minimum shall be embedded into mud -set Portland Cement applied with a'/4" minimum square notched trowel. Pavers should then be carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. Maximum Design Pressure: -255 psf. (See General Limitation #9) MIAMFDADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 16 of 74 Membrane Type: Deck Type 3I: Deck Description: System Type A(3): All General and System Substrate Preparation: Primer: Base/Ply Sheet: Membrane Integrity Test: SBS Concrete, Insulated Terrace/Plaza Deck, Planter, Traffic Membrane adhered directly to primed concrete deck. Insulation adhered under surfacing for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Concrete shall be primed with ASTM D 41 primer applied to top of composite board or top of cover board in insulation assembly. One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene Flam 250 FR+ GR, Soprastar Flam torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by afl• • approved lab. Water maybe maintained for a period longer Shari 24 hours tf required. One or more layers of any of the following insulations. ' • Insulation Layer Insulation Fasteners• • • • • Fast3tlgr• • • • Densfty/fti. . . • • .. (Table 3) STYROFOAM High Load 60 Insulation, STYROFOAMTM PLAZAMATETM Minimum 1.5" thick N/A 00 00 .0 Oil • Note: All layers of insulation shall be adhered with Duotack adhesive beads spiced 12" o.c.:leak refer to Roofing Application Standard RAS 117 for insulation attachment. £nsulation listed as base layer only shall be used only as base layers with a second layer of approved top 'lam insulation as the final membrane substrate. Inspection: Protection Board / Drainage Layer: (Optional) Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards and traffic surfacing. All defects observed shall be corrected. Install drainage board over top ply membrane Surfacing: Structural Concrete Slab, minimum 2500 psi, in compliance with applicable Building Code. Maximum Design N/A (Topping concrete slab shall comply with applicable Building Code Pressure: requirement.) MIAMFDADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 17 of 74 Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural Concrete or Min. 18-22 ga., A1008 SS Grade 33, Type B steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 24 in. o.c. System Type D(1): • Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A N/A Nate! Load c aciD' of the structural substrate must be verified for the additional load of the • • I,'Wr.;The MC trust be properly vented. When any insulation is installed directly over LWC it nfdst Ile sepdr*anaby a slip sheet or approved membrane. • • • • • Middle Insulation Layer (Optional) Insulation Fasteners Fastener • • • • • • • • . • ' • (Table 3) Density/ft2 eic Fevm-II,VontiakISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sbpta-ISO x • • • • • • Minimum 1.S nta N/A N/A • • • • Top Lrsulatip .Laxer (Optional) Insulation Fasteners Fastener • • •• •• • • • • • • (Table 3) Density/ft2 Sbpraboard Minimum Vs" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum '/4" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMI-DADE COUNTY APPROVED One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 18 of 74 Fastening #1: Fastening #2: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.OADE COUNTY APPROVED Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. in a 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of —67.5 psf. See General Limitation #7.) Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. in a 4' wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of —75 psf. See General Limitation #7.) One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. •••, Required, and shall be performed in accordance with ASTM fi 599 jay an •••• approved lab. Water may be maintained for a period longer thaii'24 ?lours r•• • required. Contractor and a representative of the membrane manufacturer shall jnspecc t11e • • waterproofing assembly and notify the contractor of any defectr.'MSpection mMt take place prior to installation of any overlay insulation, protecfi3njds, drainage: boards or traffic surfacing. All defects observed shall be corrected. •• • •• • • Apply any coating listed in Table 4 above, or any Miami -Dade appro'ved cciNtrig. system. Refer to Underwriters Laboratories or Intertek Testint Se ices listings for applicable fire classifications. See Fastening options above. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 19 of 74 Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural Concrete or Min. 18-22 ga., A1008 SS Grade 33, Type B steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 24 in. o.c. System Type D(2): • Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight Insulating Concrete Minimum 2.0" thick, Minimum 300 psi. N/A N/A ••. • • &iotertoad .a'paci>iy of the structural substrate must be verified for the additional load of the • • LAV.;The IMO Must be properly vented. When any insulation is installed directly over LWC it nfd'st Ife sepd1"atgdby a slip sheet or approved membrane. • • • • • Middy Insulatian,Layer (Optional) Insulation Fasteners Fastener •..' • •••. (Table 3) Density/ft2 • • A .Fe im-II,ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Septa -ISO x •• •• • .• Mitimum 1.3"3hT N/A N/A • fiop nsulatigr Later (Optional) Insulation Fasteners Fastener • •• • • • • • • (Table 3) Density/ft2 S6praboard Minimum 2/8" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum '/4" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMFOADE COUNTY APPROVED One layer of Soprafix Base 621, Soprafix, Soprafix Base 622, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 Sanded or Sopralene 250 SP fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 20 of 74 Fastening #1: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide, torch -applied base sheet side laps. (Meets Maximum Design Pressure of —67.5 psf. See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide, torch -applied base sheet side laps. (Meets Maximum Design Pressure of -75 psf. See General Limitation #7.) Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 Ultra FR GR, Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded or Soprastar Sanded fully adhered to the base sheet with COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive, FM Adhesive , FM Adhesive (VOC) or Soprastar Adhesive at 1.5 — 2.0 gallons/square. The 3" wide side laps are adhered with the Integrity Test: Inspection: same adhesive or torch -applied.•. • • • • Required, and shall be performed in accordance with ASTM 11i957 by an .. • approved lab. Water may be maintained for a period longer thamQ11.1tours i required. • .... .. . . • Contractor and a representative of the membrane manufacturei'411411 fnspecttltl1 , • waterproofing assembly and notify the contractor of any defects..lcsection must. • • take place prior to installation of any overlay insulation, protection pads, drainage: boards or traffic surfacing. All defects observed shall be corrctect.•: • • Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade apprpved cc tihr • • • (Optional) system. Refer to Underwriters Laboratories or Intertek TestinUervices listings . • . for applicable fire classifications. •' • • Maximum Design Pressure: See Fastening options above. MIAMI.DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 21 of 74 Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural concrete or Min. 22 ga., A1008 or A653 Grade 80, Type B steel deck fastened to 3/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(3): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ctreb -e MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight . Idsi7Ating Collared, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight • • Insula> in•g Concrete Minimum 2.Q'; j4ijc, Minimum 300 psi. N/A N/A • . lYbtuf oad carAtity of the structural substrate must be verified for the additional load of the LIVC.1'he L\ tmust be properly vented. When any insulation is installed directly over LWC it • must 1 e separgted,Dy a slip sheet or approved membrane. • Middle InsulitiptI' ayer (Optional) Insulation Fasteners Fastener • • (Table 3) Density/ft2 ACFoa'm-II, Isopra.SO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, • &opra ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 0.125" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMI.DADE COUNTY APPROVED One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 22 of 74 Fastening #1: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -67.5 psf. See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -75 psf. See General Limitation #7.) Fastening #3: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. in a 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -120 psf. See General Limitation #7.) Fastening #4: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2.4" Seam PJB with row spacing at a maximum 35.5" o.c. The fasteners are s1aced 6" o.c.iva. • 4" wide torch -applied base sheet side laps. • • • •. • •• • (Meets Maximum Design Pressure of -142.5 psf. See Generalot n'tation #7.j•� • Ply Sheet: One or more plies of Elastophene Flam, Elastophene Flam 2.2, Ela$tophene $P • • • (Optional) 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, S imulene Flail f84,• Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, 6olxalene 1�0 . • SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied! • • • • • • • • • • • Membrane: Elastophene Flam LS FR GR, Soprafix • Cap FR -651, Sopralent Flant 180 UR, • • • • Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopraleue Flam 180 FR• • • • GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3 S., Sc. raleneJ lam • 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, .•: Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved coating (Optional) system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design Pressure: See Fastening options above. MIAMFOADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 23 of 74 Membrane: Deck Type 7I: Deck Description: SBS Recover, Insulated Structural concrete or min. 22 ga., Type B, Grade 80 ksi steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(4): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate Preparation: All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 34eore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight IfShcating Caere*, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight It sulaiing Concrete M nimum 2.b4tT►ick, Minimum 300 psi. N/A N/A LVbte'Load caratIte of the structural substrate must be verified for the additional load of the LWC.•The LVVt must be properly vented. When any insulation is installed directly over LWC it mustne separated ly a slip sheet or approved membrane. Middle Insulpttar.ayer (Optional) Insulation Fasteners • (Table 3) ACFodm-II, Sgpra:ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sopra YSO x • • Minimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener Density/ft2 N/A Fastener Density/ft2 Sopraboard Minimum 1/8" thick (Table 3) N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum'/" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMI.DADE COUNTY APPROVED One layer of Soprafix Base 621, Soprafix, Soprafix Base 622, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 Sanded or Sopralene 250 SP fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 24 of 74 Fastening #1: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch-applied base sheet side laps. (Meets Maximum Design Pressure of -67.5 psf. See General Limitation #7.) Fastening #2: Attach base sheet using Trufast #14 HD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch-applied base sheet side laps. (Meets Maximum Design Pressure of -75 psf. See General Limitation #7.) Fastening #3 Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch-applied base sheet side laps. (Meets Maximum Design Pressure of -97.5 psf. See General Limitation #7.) Fastening #4: Attach base sheet using Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Trufast 2.4" Scoop Seam Plates or SOPREMA #14 MP or SOPREMA #15 HD Fasteners with SOPREMA 2"i'eam• • Plates or SOPREMA 2.4" Seam Plates with row spacing at a ftwtmgm 35,5: o.i. • • The fasteners are spaced 6" o.c. and centered inside the 4" widetQ -applied..' • base sheet side laps. . (Meets Maximum Design Pressure of -120 psf. See General Liirnilation #i•)) •• Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR,.Sggr t1ene 1 �0 FIS GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene .l D.I?ltra FRGR•: Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 UitraFtiR GR, . Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded or Soprtlstar 4Inded(fully adhered to the base sheet with COLPLY EF Adhesive, COLPVIeclhesive, COLPLY Modified Adhesive, FM Adhesive, FM Adhesive (VM) dr Sopfdttar ; Adhesive at 1.5 — 2.0 gallons/square. The 3" wide side laps are adhered with th'e' same adhesive or torch-applied. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami-Dade approved coating (Optional) system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design Pressure: See Fastening options above. MIAMIOADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 25 of 74 • •• • • Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural concrete or min. 22 ga., A1008 or A653 Grade 80 ksi steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(5): Menibrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 C•eitore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight •• Insu�a�ing Cene ate, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight • hjsulajing Cupicq,tt Mipimum 2.1)13bic.k, Minimum 300 psi. N/A N/A A1•ote:oad capacity of the structural substrate must be verified for the additional load of the t.VVC, The L fica>lust be properly vented. When any insulation is installed directly over LWC it OAS J* sepa1attd by a slip sheet or approved membrane. • •• Middle Insul*�tibh'j.ayer (Optional) Insulation Fasteners Fastener ••(Table 3) Density/ft2 ▪ ACFoam-II, opj a%ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, ▪ lgpra-ISO x Minimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum'/" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One layer of Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: Fastening#1: MIAMFDADE COUNTY APPROVED Attach base sheet using Trufast #15 EHD Fasteners and SOPREMA #15 HD Fasteners with Trufast 2.4" Scoop Seam Plates and SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 12" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maxi mum Design Pressure of -97.5 psf. See General Limitation #7.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 26 of 74 Fastening #2: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMIOADE COUNTY APPROVED Attach base sheet using Trufast #15 EHD Fasteners and SOPREMA #15 HD Fasteners with Trufast 2.4" Scoop Seam Plates and SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -172.5 psf. See General Limitation #7.) One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours i,f"". required.• ..• . ..• Contractor and a representative of the membrane manufacturer Sh�14 inspect the • waterproofing assembly and notify the contractor of any defects.' Msbection mast take place prior to installation of any overlay insulation, proteofion Fads, draina& boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade appibved coatfig' • system. Refer to Underwriters Laboratories or Intertek Testink'Ser4Zces listing's for applicable fire classifications. See Fastening options above. • 11• • .• • ••• • • • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 27 of 74 Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural concrete or min. 22 ga., A1008 SS Grade 33, Type B steel deck fastened to 'A" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(6): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Clltbtg MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight • InTldting Codaretd, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight • • Msuk ting Concrete Minimum 24'.thiFic, Minimum 300 psi. N/A N/A ••Ndte; Thad caridc�i1y of the structural substrate must be verified for the additional load of the • • L'GVC. The IAN/ must be properly vented. When any insulation is installed directly over LWC it nous .tie separ3tgd.I2Y a slip sheet or approved membrane. • • Middle Insullt'iv[4:ayer (Optional) Insulation Fasteners Fastener • • (Table 3) Density/ft2 ACFoatn-II, Sdpra-SO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, ••Srapa fSO x • • • 11,11nimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum Vs" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board MinimumVI" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMI.OADE COUNTY APPROVED One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 28 of 74 Fastening: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMtDADE COUNTY APPROVED Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2" Seam Plates or SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. in a 4" wide torch -applied base sheet side laps. One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene Flam Antirock, torch -applied. The 3" wide side laps of the cap sheets are torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if"". • . •••• required. • • • •• • • Contractor and a representative of the membrane manufacturer Sh/14 inspect the • • waterproofing assembly and notify the contractor of any defeclS.' his$ection mast take place prior to installation of any overlay insulation, protecfiMlaads, du'aii ae . boards or traffic surfacing. All defects observed shall be corrected. • • • • Apply any coating listed in Table 4 above, or any Miami -Dade ilppioved coating, • system. Refer to Underwriters Laboratories or Intertek Testint'SP.Ii' ces listing% •for applicable fire classifications. • • • -112.5 psf. (See General Limitation #7.) • • • • • . •• • ••• • • • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 29 of 74 • Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural concrete or Min. 18 ga., Type B, Grade 33 steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners and 3/4" diameter steel washers spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(7): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 cfiteddrr MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Idgiflting Concrete, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight IEnsulaiing Concrete •1irimum 2.Q'3aicJc, Minimum 300 psi. N/A N/A • • Ditto:'Load Watt* of the structural substrate must be verified for the additional load of the • • LWC..The LWrmust be properly vented. When any insulation is installed directly over LWC it uslpe sepal -MN, py a slip sheet or approved membrane. �• Middle Insult 1f ayer (Optional) Insulation Fasteners Fastener • (Table 3) Density/ft2 ••ACFodm-II,>s'opra:ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, • • Sorg -ISO x. e. Minimum 1.5" thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 1/8" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 'A" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: MIAMI-DADE COUNTY APPROVED One layer of Soprafix Base 621, Soprafix, Soprafix Base 622, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 Sanded or Sopralene 250 SP fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 30 of 74 Fastening: Attach base sheet using Trufast #15 EHD Fasteners with Trufast 2" Barbed Metal Seam Plates or Trufast 2.4" Scoop Seam Plates or SOPREMA #15 HD Fasteners with SOPREMA 2" Seam Plates or SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 180 FR+ GR, Sopralene 180 Ultra FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, Sopralene 250 Ultra FR GR, Sopralene 250 FR+ GR, Sopralast 50 TV Alu Sanded or Soprastar Sanded fully adhered to the base sheet with COLPLY EF Adhesive, COLPLY Adhesive, COLPLY Modified Adhesive, FM Adhesive , FM Adhesive (VOC) or Soprastar Adhesive at 1.5 — 2.0 gallons/square. The 3" wide side laps are adhered with the same adhesive or torch -applied. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. ." .... • Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved coating • (Optional) system. Refer to Underwriters Laboratories or Intertek TestingStritces listings• for applicable fire classifications. • Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED -112.5 psf. (See General Limitation #7.) . .... • •. •. • . . • . . . . .. • • . . • . . • •. . . . . ..• •• . . ••• • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 31 of 74 • • Membrane: SBS Deck Type 7I: Recover, Insulated Deck Description: Structural concrete or min. 22 ga., A1008 or A653 Grade 80 ksi steel deck fastened to 1/4" thick steel structural supports spaced a maximum of 6' o.c. with Traxx/5 fasteners spaced a maximum 6" o.c. at the supports. Side laps are fastened with Traxx/1 fasteners spaced 12 in. o.c. System Type D(8): Membrane fastened over preliminarily secured insulation. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Celcore MF Cellular Concrete, Siplast Lightweight Insulating Concrete, Elastizell Lightweight Insulating Concrete, Concrecel Lightweight Insulating Concrete or Mearlcrete Lightweight Imulating Concrete Mi'tfitnum 2.04".thidk, Minimum 300 psi. N/A N/A Note: Load oa'pncity of the structural substrate must be verified for the additional load of the • LWC. The LaWe Must be properly vented. When any insulation is installed directly over LWC it • qt isrtte sepajted by a slip sheet or approved membrane. .• • •••. • • 'piddle Insulati Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 AGFoam-II, fora:ISO s, ISO 95+ GL, Ultra -Max, H -Shield, M -Shield, Sopra-ISO r, Sed A- ISO x • • • • Minimbm 1.5" thick N/A N/A . . . ... . .. top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Sopraboard Minimum 0.125" thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 0.25" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base sheet. Insulation shall be limited to maximum 1" thickness. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One layer of Soprafix Base 611, Soprafix Base 610, Soprafix Base 630, Soprafix, Soprafix Base 622, Soprafix [S], Soprafix Base 612, Soprafix [F], Soprafix Base 613, Soprafix [X] or Soprafix Base 614 fastened to the deck as described below: NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 32 of 74 Fastening #1: Fastening #2: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.OADE COUNTY APPROVED Attach base sheet using Trufast #14 HD Fasteners with Trufast 2" Barbed Metal Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -120 psf. See General Limitation #7.) Attach base sheet using Trufast #14 HD Fasteners with Trufast 2.4" Scoop Seam Plates or SOPREMA #14 MP Fasteners with SOPREMA 2.4" Seam Plates with row spacing at a maximum 35.5" o.c. The fasteners are spaced 6" o.c. and centered inside the 4" wide torch -applied base sheet side laps. (Meets Maximum Design Pressure of -135 psf. See General Limitation #7.) One or more plies of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Soprafix Cap FR -651, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 180 Ultra FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 Ultra FR GR, Sopralene Flam 250 FR+ GR, Soprastar Flam, Sopralast 50 TV Alu, Sopralene.Flana Antirot • • • torch -applied. The 3" wide side laps of the cap sheets are torch.applaied. .. • Required, and shall be performed in accordance with ASTM D 595Vby an: •..' approved lab. Water may be maintained for a period longer thati'2Ohours if • required. •••• • •• • . . . .... •.•.. Contractor and a representative of the membrane manufacturer shall inspect the . waterproofing assembly and notify the contractor of any defects. faspectionnxust: take place prior to installation of any overlay insulation, protetteltnids, drainage boards or traffic surfacing. All defects observed shall be corrected. • • • • . • Apply any coating listed in Table 4 above, or any Miami -Dade approved coating . system. Refer to Underwriters Laboratories or Intertek Testing Services listings.: for applicable fire classifications. See Fastening options above. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 33 of 74 Membrane Type: Deck Type 4: Deck Description: System Type E(1): All General and System Structural Deck: LWIC: Substrate Preparation: Base Sheet: .... Ply Sheet:• • • • • .• • .. • •• • • •. • . . •• • •• • • • •• •• Membrane: • • • • .•• .. • ...• • • .... • • .. •. • • • • • • . • • .. Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI OADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Mearlcrete Lightweight Insulating Concrete, min. 200 psi. Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. Min. 22 ga. Grade 33, Type BV Steel Deck attached 6" o.c. with 3/8 in. welding washers to steel supports spaced max 5 ft. o.c. Deck side laps are attached with 2 #10 steel self -tapping screws evenly spaced between purlins or min 2,500 psi structural concrete. Mearlcrete Lightweight Insulating Concrete, min. 200 psi, wet cast density 40 pcf, with minimum 1.5" thick EPS board embedded in 1/8" slurry. Followed by, wet cast density 40 pcf, minimum 2" thick top coat. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Sopra G mechanically with OMG CR Base Ply Fasteners (1.7) spaced 7 -inch o.c. at the 4 -inch laps and 7 -inch o.c. in two equally spaced, staggered center rows. One ply of Elastophene Sanded, Colphene Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS*, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Sopra IV or Sopra VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR+ GR, torch -applied. Or Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced ply membrane. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -52.5 psf. (See General Limitation #7.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 34 of 74 Membrane Type: SBS Deck Type 4: Lightweight Decks, Non -Insulated Deck Description: Concrecel Concrete, min. 400 psi. System Type E(2): Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Pla7a Decks, Planters or Traffic Areas All General and System Limitations apply. Structural Deck: Min. 22 ga. Grade SS80, Type B Steel Deck attached 6" o.c. with 5/8 in. puddle welds and washers to steel supports spaced max 5 ft o.c. Deck side laps are attached with Traxx/1 screws spaced 12" o.c. or min 2,500 psi structural concrete. LWIC Deck: Concrecel Bonding Agent applied to deck at a rate of 600 ft2/gal; Concrecel Concrete, 46.4 pcf wet cast density, min. 400 psi, concrete pour consisting of a 1/4" slurry coat, minimum 1" thick Holey Board and a minimum 2-1/4" thick top coat, 43 pcf wet cast density. Followed by Concrecel Curing Compound spay -applied at a rate of 600 ft2/gal. Base Sheet: Sopra G or Modified Sopra G mechanically attached with OMG CR Base Ply Fasteners (1.7") spaced 7 -inch o.c. at the 3 -inch laps and 7-i>lch o.c. in two, ... • equally spaced, staggered center rows. • • • •• • • Ply Sheet: One ply of Elastophene Flam*, Elastophene Flam 2.2*, Elastophene SP 272, •• Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopr§lag Flam 1804,. Colphene Flam 180, Sopralene 180 SP 3.5, Colphene 180 SP 3•„1.4oprafi=c, •••• Soprafix Base 622, Sopralene Flam 250*, Sopralene 250 SP, keakwelded.. . Membrane: MIAMI.DADE COUNTY APPROVED Or • • . • . .. .. .. •. One ply of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0�.: • Elastophene HS, Elastophene PS*, Elastophene PS 3.0*, El$stopflene 188 Sanded, Colphene 180 Sanded, Elastophene 180 PS*, Colphene 180 PS*, ; Sopralene 180 PS 2.2*, Sopralene 180 Sanded, Sopralene 180 PS*, Sopralene" 250 Sanded, or one to three plies of Sopra IV or Sopra VI ply sheet, adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive, or Soprastar Adhesive at 1.5 — 2.0 gallons/square to sand surfaced base membrane. *Requires heat welded cap membrane. One layer of Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, heat welded. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 35 of 74 • • Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 1.5 — 2.0 gallons/square to sand surfaced ply membrane. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved (Optional) coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design .... Prnsirre: -52.5 psf. (See General Limitation #7.) • . • • .• • •• •• • • ••• • • • • • •• • • • •. • • • • • • • • •• . • • .••• • •••• • • •• •• • • • • • • • • • • • • • ••• • • •• • • •• •• MIAMIDADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 36 of 74 Membrane Type: Deck Type 4: Deck Description: System Type E(3): All General and System Structural Deck: LWIC Deck: Base Sheet: Ply Sheet: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.DADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Concrecel Concrete, min. 400 psi. Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. Min. 22 ga. Grade SS80, Type B Steel Deck attached 6" o.c. with 5/8 in. puddle welds and washers to steel supports spaced max 5 ft o.c. Deck side laps are attached with Traxx/1 screws spaced 12" o.c. or min 2,500 psi structural concrete. Concrecel Bonding Agent applied to deck at a rate of 600 ft2/gal; Concrecel Concrete, 46.4 pcf wet cast density, min. 400 psi, concrete pour consisting of a 1/4" slurry coat, minimum 1" thick Holey Board and a minimum 2-1/4" thick top coat, 43 pcf wet cast density. Followed by Concrecel Curing Compound spay -applied at a rate of 600 ft2/gal. Sopralene 180 Sanded or Colphene 180 Sanded mechanically attached with OMG CR Base Sheet Fastener (1.2" or 1.7") spaced 7 -inch o.c. at the 4 -inch laps and 7 -inch o.c. in two equally spaced, staggered center rows. One ply of Elastophene Sanded, Colphene Sanded, Elastophene 180 Sanded,• • Colphene 180 Sanded, Elastophene PS*, Elastophene PS 3.0*, Etastopheri,•110 PS*, Colphene 180 PS, Sopralene 180 PS 2.2*, Sopralene 18!):PS4, Sopne. 180 Sanded, Sopralene 250 Sanded or one or more plies of app.:dit IV or Sopra VI ply sheets adhered in a full mopping of approved asphalt gpyljed witllip t�i� EVT range and at a rate of 20-40 lbs./sq. to sand surfaced bt mdlnbrart. • • . • *Requires torch -applied cap membrane. • . Elastophene Flam GR, Elastophene Flam FR GR, ElastophMe FT= FR+(3R,• • Elastophene Flam LS FR GR, Soprastar Flam, Sopralene Film 08a GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 111,V111. GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR OILSocralene.ttam. 180 FR+ GR, Sopralene Flam 250 FR+ GR, torch -applied. Or Elastophene FR GR, Elastophene LS FR GR, Elastophene GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced ply membrane. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or lntertek Testing Services listings for applicable fire classifications. .. -60 psf. (See General Limitation #7.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 37 of 74 Membrane Type: Deck Type 4: Deck Description: System Type E(4): All General and System Structural Deck: LWIC Deck: 0000 0600 • 0• • • • 0• • • . • •• • • • •0 $ubcfiate 0000 • P• rep�rationy •• • . • •0 0• .. .• Bak Sheet: • • • • • • • • 0.0 •• Ply Sheet: (Optional) • • • •• • • • •• MIAMI-DADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi, Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. Structural concrete or 18-22 ga. Type B steel deck installed and welded to minimum 0.25 in. thick steel structural supports spaced maximum 5' o.c. using 3/8" diameter weld washers 6" o.c. at each bearing. The deck side laps are fastened at 30" o.c. using Traxx/1 fasteners. Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with a minimum wet cast density of 38 lbs./f3, min. 300 psi, filling the corrugation with a minimum depth of 1/8". The Celcore HS admixture was added to the mixture during the mixing process at a rate of 3.4 fl. oz. per 100 lbs. of cement. Minimum 1" thick Holey Boards are then immediately placed in a brick -like pattern into the wet concrete and allowed to set overnight. The following day, a minimum 2" thick topping layer of Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture is placed atop the EPS at a wet cast density of 38 lbs./ft3, min. 300 psi. After an overnight set, Celcore PVA Curing Compound is spray applied to the lightweight concrete at a rate of 0.33 gal/sq. and allowed to dry for 48 hours. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene Sanded, Colphene Sanded, Sopra G, Modified Sopra G, Sopra IV, Sopra VI, Soprafix, Soprafix Base 622, Soprabase*, Soprabase S* mechanically attached with FM - 90 or SOPREMA 1.7 in. Base Sheet Fastener spaced 9" o.c. at the 4" laps and 12" o.c. in two equally spaced, staggered rows. *Requires asphalt applied or cold applied ply sheets. Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250* or Sopralene 250 SP, torch -applied with minimum 3" wide lap. Or Elastophene Sanded, Colphene Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Sopra IV or Sopra VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 38 of 74 Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprafix Cap FR -651, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 1.5 — 2.0 gallons/square to sand surfaced ply membrane. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected! • • .... Surfacing: Apply any coating listed in Table 4 above, or any Miami-Dadea'pp%oved.. . • • (Optional) coating system. Refer to Underwriters Laboratories or Inter4alo testing : '..' • Services listings for applicable fire classifications. . ••.. .. . Maximum Design -60 psf. (torch applied membranes) (See General Limitation•147.). • •• ••.. • Pressure: -52.5 psf. (all other membrane applications) (See General Limitation #7.) . • • • • • • MIAMI•DADE COUNTY APPROVED • • • • • • • • • • •• • • • • • • ••••. • • • • • • • ••• • • • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 39 of 74 • • • .••. • . • • • • • • Membrane Type: Deck Type 4: Deck Description: System Type E(5): All General and System Structural Deck: Thermal Barrier: .... Vr*Barrigr . • • • .. • .. • • • .•• • • • • .. .... l•WfCbeck.••••• • • • • •• • •• •• •• •• • • • • • ... •• Base Sheet: Ply Sheet: (Optional) Membrane: . . • • • •• • • • • .. MIAMI DADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Base sheet mechanically attached to the primed substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas Limitations apply. 18-22 ga. Grade 33, galvanized steel deck installed and welded to minimum 0.25 in. thick steel structural supports spaced maximum 6' o.c. using 3/8" diameter weld washers 6" o.c. at each bearing. The deck side laps are fastened at 24" o.c. (three evenly spaced fasteners between supports) using Teks 1 or Traxx/1 fasteners between supports. Or structural concrete deck. Min. 0.625 -inch SECUROCK Gypsum -Fiber Roof Board mechanically fastened with OMG Heavy Duty fasteners, OMG 3" Galvalume Steel Plates, Dekfast Galvalume Steel Hex plates, Dekfast Galvalume Steel 3" Round plates, Dekfast 14 fasteners, Trufast 3" Metal Insulation Plates and Trufast #14 Stainless Steel HD Fasteners or SOPREMA 3" Round Insulation Plate and SOPREMA #14 Fasteners at a rate of 1 per 1.6 ft2. One layer of Elastophene SP 2.2 or Colphene SP 2.2, torch -applied with minimum 3" wide lap or one layer of Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene Sanded, Colphene Sanded, Sopralene 180 Sanded or Sopralene 250 Sanded, hot asphalt applied. Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with a min. 300 psi, min. wet cast density of 43.5 lbs./ft3, filling the corrugation with a minimum depth of 1/8". The Celcore HS admixture was added to the mixture during the mixing process at a rate of 3.4 fl. oz. per 100 lbs. of cement. Minimum 1" thick Insulfoam EPS Holey Boards are then immediately placed in a brick -like pattern into the wet concrete and allowed to set overnight. The following day, a minimum 2" thick topping layer of Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture is placed atop the EPS at a wet cast density of 45 lbs./ft3, min. 300 psi. Sopra G, Modified Sopra G or Sopra VI mechanically attached with FM -90, SOPREMA 1.7 in. Base Sheet Fastener or OMG CR Base Ply Fasteners (1.7") spaced 7 -inch o.c. at the 3 -inch laps and 7 -inch o.c. in two equally spaced, staggered center rows. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprafix Cap FR -651, torch -applied. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 40 of 74 Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved (Optional) coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design Pressure: MIAMI.DADE COUNTY APPROVED -60 psf. (See General Limitation #7.) 11000 .. . . 0000 . . . • .. . .. .. . . • .0 0 . . ... . . • • 0000 • 0. . • . . . .. .. .. 00 . . . . • . . . . . .. • . ▪ . .. • 0.0 • • • 00 NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 41 of 74 • • • • • • Membrane Type: Deck Type 4: Deck Description: System Type E(6): All General and System Structural Deck: Thermal Barrier: (Optional) Vapor Barrier: (Optional) . • .. • • L'Wtt Deck, . • •. • •. .• . . •. • • .. •••• .• . . .. •• •... gax Skeet: •••••• • . • . • . . . • . . . • . ... . •. .• Ply Sheet: (Optional) MIAMI-DADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Celcore MF Cellular Concrete, min. 350 psi Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 18-22 ga. Grade 33, galvanized steel deck installed and welded to minimum 0.25 in. thick steel structural supports spaced maximum 6' o.c. using 3/8" diameter weld washers 6" o.c. at each bearing. The deck side laps are fastened at 24" o.c. (three evenly spaced fasteners between supports) using Teks 1 or Traxx/1 fasteners between supports. Or structural concrete deck. (Wth steel deck only) Min. 0.625 -inch SECUROCK Gypsum -Fiber Roof Board mechanically attached with OMG Heavy -Duty fasteners and OMG 3" Galvalume Steel Plates at 1.6 ft2. Elastophene SP 2.2, Elastophene SP 3.0, Colphene SP 2.2, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied over substrate primed with Elastocol 500, Elastocol Stick or ASTM D41 primer. A 1/8" slurry coat of, min. 350 psi, 43.5 pcf wet cast density, Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with min. 1" thick Holy Board and a minimum 2" thick top coat, min. 350 psi, 43.5 pcf wet cast density. After setting to support foot traffic, Celcore PVA Curing Compound is applied at a rate of 0.33 gal/square. Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene Sanded, Colphene Sanded, Sopra G, Modified Sopra G, Sopra 1V, Sopra VI, Soprafix, Soprafix Base 622, Soprabase*, Soprabase S* mechanically attached with FM - 90 or SOPREMA 1.7 in. Base Sheet Fastener spaced 9 -inch o.c. at the 4 -inch laps and 12 -inch o.c. in two equally spaced, staggered center rows. *Requires asphalt applied or cold applied ply sheets. Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250* or Sopralene 250 SP, torch -applied with minimum 3" wide lap. Or Elastophene Sanded, Colphene Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Sopra IV or Sopra VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 42 of 74 Membrane: Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprafix Cap FR -651, torch -applied. Or Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Soprastar Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 1.5 — 2.0 gallons/square to sand surfaced ply membrane. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected.. • • Surfacing: Apply any coating listed in Table 4 above, or any Miami-DttcJe� approved. . • . • (Optional) coating system. Refer to Underwriters Laboratories or Inte4e1aesting : •.. • Services listings for applicable fire classifications. . Maximum Design -60 psf. (torch applied membranes) (See General Limitation q')}. • •.• • •'. Pressure: -52.5 psf. (all other membrane applications) (See General LiMa ion #7.). •' • • . • . . ..• ..• ..• .. MIAMNDADE COUNTY APPROVED • •• • • • . . • • • • • . . .• . • ... • 410 NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 43 of 74 • • • • . • . . Membrane Type: Deck Type 4: Deck Description: System Type E(7): All General and System Structural Deck: LWIC Deck: .... Bast Sheet: . . • • . • .. • . . • . . .. . . • .. .. . .. • .... .... • . • • . • . .. .. .. .. Ply•Sheet: • . • . . . • • .• . . . . • . . ... • .. .. Membrane: MIAMI.DADE COUNTY APPROVED SBS Lightweight Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi, min. Base sheet mechanically attached directly to substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 18-22 ga. Grade 33, Type B steel deck secured to the structural supports 6" o.c. with 1" welds and washers spaced maximum 5' o.c. The deck side laps are fastened at 24" o.c. (three evenly spaced fasteners between supports) using Traxx/1 screws between supports or min. 2,500 structural concrete. Celcore MF Cellular Concrete, min. 300 psi, min. wet cast density of 42 lbs./ft3, with Celcore HS Rheology Modifying Admixture applied in a min. 1/8" slurry. Minimum 1" thick Holey Boards are then immediately placed into the wet concrete and allowed to set overnight. The following day, a min. 2" thick topping layer of Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture is placed atop the EPS. After an overnight set, Celcore PVA Curing Compound is spray applied to the lightweight concrete at a rate of 300 ft2/gal. Sopra G, Modified Sopra G, Sopra IV, Sopra VI, Soprabase*, Soprabase S* mechanically attached with FM -90, SOPREMA 1.7 in. Base Sheet Fastener or OMG CR Base Ply Fasteners (1.7") or Soprabase, Soprabase S mechanically attached with FM -90 or SOPREMA 1.7 in. Base Sheet Fastener spaced 7 -inch o.c. at the 3 -inch laps and 7 -inch o.c. in two equally spaced, staggered center rows. *Requires asphalt applied or cold applied ply sheets. Elastophene Flam*, Elastophene Flam 2.2*, Elastophene Flam HS*, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180*, Colphene Flam 180*, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250* or Sopralene 250 SP, torch -applied with minimum 3" wide lap. Or Elastophene Sanded, Colphene Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Elastophene PS*, Elastophene PS 3.0*, Elastophene 180 PS*, Colphene 180 PS, Sopralene 180 PS 2.2*, Sopralene 180 PS*, Sopralene 180 Sanded, Sopralene 250 Sanded or one or more plies of Sopra IV or Sopra VI ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. to sand surfaced base membrane. *Requires torch -applied cap membrane. Elastophene Flam GR, Elastophene Flam FR GR, Elastophene Flam LS FR GR, Elastophene Flam FR+ GR, Soprastar Flam, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, Soprafix Cap FR -651, torch -applied. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 44 of 74 Or Membrane: Elastophene GR, Elastophene FR GR, Elastophene LS FR GR, Soprastar (Continued) Sanded, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR or Colphene 250 FR GR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in FM Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 1.5 — 2.0 gallons/square to sand surfaced ply membrane. Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved (Optional) coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design -75 psf. (torch applied membranes) (See General Limitation #7.) Pressure: -52.5 psf. (all other membrane applications) (See General Limitation #7.) MIAMI•DADE COUNTY APPROVED .. . • .. . . •• .. . • . .... .. • . • . .... . .. • • . • . .. .• .. .. . • • . • . •. .. . • . .. . ... . NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 45 of 74 • • Membrane Type: Deck Type 4: Deck Description: System Type E(8): All General and System Structural Deck: Thermal Barrier: (Optional) Vapor Barrier: (Optional)_ .0000. .... . . •• • . LWebeck: • • • .. • • .. • • • •. • .... • • •••• lase skeet: • • .. .. .. .. . • . . • • • . • • .. • • ... .• .. • • Ply Sheet: (Optional) Membrane: Integrity Test: MUUfflOADECOUNTY APPROVED SBS Lightweight Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Base sheet mechanically attached to the primed substrate. Membranes adhered to base sheet for Terrace/Plaza Decks, Planters or Traffic Areas Limitations apply. Min. 22 ga. Grade 33, painted or galvanized steel deck attached 6" o.c. with 3/8 in. weld washers to steel supports spaced max 6 ft o.c. Deck side laps are attached with Traxx/1 screws spaced 24" o.c or min. 2,500 structural concrete (With steel deck only) Min. 0.625 -inch SECUROCK Gypsum -Fiber Roof Board mechanically fastened with OMG Heavy Duty fasteners, OMG 3" Galvalume Steel Plates, Dekfast Galvalume Steel Hex plates, Dekfast Galvalume Steel 3" Round plates, Dekfast 14 fasteners, Trufast 3" Metal Insulation Plates and Trufast #14 Stainless Steel HD Fasteners, or SOPREMA 3" Round Insulation Plate and SOPREMA #14 Fasteners at a rate of 1 per 1.6 ft2. Elastophene SP 2.2, Elastophene SP 3.0, Colphene SP 2.2, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, torch -applied over substrate primed with Elastocol 500, Elastocol Stick or ASTM D41 primer. A 1/8" slurry coat of, min. 300 psi, Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with min. 1" thick Holy Board and a minimum 2" thick top coat. After setting to support foot traffic, Celcore PVA Curing Compound is applied at a rate of 0.33 gal/square. One ply of Sopra G, Modified Sopra G or Sopra VI mechanically attached with FM -90, SOPREMA 1.7 in. Base Sheet Fastener or OMG CR Base Ply Fasteners (1.7") or Soprabase, Soprabase S mechanically attached with FM -90 or SOPREMA 1.7 in. Base Sheet Fastener spaced 7 -inch o.c. at the 3 -inch laps and 7 -inch o.c. in two equally spaced, staggered center rows. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam, Soprafix Cap FR -651, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 46 of 74 Inspection: Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Surfacing: Apply any coating listed in Table 4 above, or any Miami -Dade approved (Optional) coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. Maximum Design Pressure: -75 psf. (See General Limitation #7.) MIAMI-DADE COUNTY APPROVED . . . . .. . .. . . • • • .. • • •••• .. . • • • •••• • • .. • • .. .. • • • • • • • • .. • • • • • • .. • . • • • • • • • . • • • ••• • • • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 47 of 74 • • • . . • Membrane Type: Deck Type 3: Deck Description: System Type F(1): All General and System Substrate Preparation: Primer: Base Sheet: Membrane: .... • • .• • • • .. . .. • • • .• • • .. .... .• . • .. . .... • . • . • . . .. .. .. .. . . • • • .. . . • • . . ... . .. .. 00 Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Concrete deck shall be primed with Elastocol Stick primer applied at a rate of 1 gal/sq. Sopralene Stick, Colphene Stick or Sopratene Flam Stick*, self -adhered. *Requires heat welded cap sheet. Soprastar Stick, Elastophene Stick FR GR, self -adhered to sand surfaced base or ply membrane primed with Elastocol Stick. Or Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopratene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopratene Flam 180 FR+ GR, Sopratene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopratene Flam 250 FR+ GR, torch -applied. Or Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR or Soprastar Sanded applied in hot asphalt at 25 lbs/square or adhered with FM Adhesive, COLPLY Adhesive, FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive at 1.5 gal/square. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -67.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 48 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(2): All General and System Substrate Preparation: Primer: Base Sheet: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry. Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with FM Adhesive or COLPLY Adhesive applied at 1.5 gal/square. Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colnhen .250 F1 : • or Soprastar Sanded adhered with FM Adhesive or COLPL•ydltdtesive • • • applied at 1.5 gal/square. • • • • •• • Required, and shall be performed in accordance with ASTM t3S957 by an ' approved lab. Water may be maintained for a period longerV 24 ho tis•if " • required. • • Contractor and a representative of the membrane manufac4.itei'3'hal1 insp2Lt • • the waterproofing assembly and notify the contractor of a Ycir its. es Inspection must take place prior to installation of any overlay insulatio l protection pads, drainage boards or traffic surfacing. All ckfgetspbserviL . shall be corrected. • •• Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -82.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 49 of 74 • .• . . Membrane Type: Deck Type 3: Deck Description: System Type F(3): All General and System Substrate Preparation: Primer: Base Sheet: Ply Sheet: (Optional) Membrane: •... .... • .• • . • •• • . • • . • • .. ••tiiteg}fty Test• • • • . •1 . .... • . . • • • . • . • •• • .. •. .. •• Inspection: . . . . • . • . • . . . • • ..• • •• •. .• Surfacing: Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500 or ASTM D 41 primer applied to deck at a rate of 100-150 ft2/gal. Colvent Flam TG or Colvent Flam 180 TG, torch -applied. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch- applied. Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene Flam 250 FR+ GR, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Wausau Terra -System One with Lok -Down adhered to the top surface of the waterproofing system in Sopramastic SP -1 at 0.30 — 0.35 gal/f0. (0.1 gal/pedestal base). Followed by the 2' x 2' Terra -Pavers and the Lok -Down securement tabs and screws. NOTE: All plastic surfaces shall be primed with Chem Link TPO Primer prior to application of Sopramastic SP -1 adhesive. -90 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 50 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(4): All General and System Structural Deck: LWIC Deck: Base Sheet: Primer: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Elastizell Lightweight Concrete, min. 300 psi. Membranes applied directly to substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. Min. 22 ga., Type B, Grade 33 vented Steel deck attached 6" o.c. with Traxx/5 screws to steel support spaced max 6 ft o.c. Deck side laps are attached with Traxx/1 screws spaced 12" o.c. Elastizell Range II with Zell -Crete Fibers, min. 300 psi, consisting of a 1/8" slurry coat, minimum 1" thick Holey Board and a minimum 2" thick top coat. Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene HD, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with Millennium Hurricane Force Membrane Adhesive with 0.5 — 1.0 -inch wide ribbons spaced 12 -inch o.c. Elastocol 500, Elastocol Stick or ASTM D 41 primer applied at rate offl'"''. gal./sq. • • • ••• • Elastophene Stick FR GR or Soprastar Stick*, self -adhered. • • • • .• • • •. • *Base layer shall be primed with Elastocol Stick prior to apekeiag cap sheet.. Required, and shall be performed in accordance with ASTM 13 n57 by an approved lab. Water may be maintained for a period longe>.tj 24 houts.if•. required. • • • Contractor and a representative of the membrane manufacturer shall inspect t13tb waterproofing assembly and notify the contractor of any dekcc,. tnspecti • must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -105 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 51 of 74 . . • • . . . . . Membrane Type: Deck Type 4: Deck Description: System Type F(5): All General and System Structural Deck: Substrate Preparation: Temp Roof: (Optional) Primer: (Optional) Base Sheet: . • .... • . • . . • •• • •• • • • .. . Pi`inagt: •.... • cirtional) •••• Membrane: •••••• . • . . . • . 1 • • ••• . . •• • . • •• Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Min. 300 psi, min 2 -inch thick Elastizell Range II with Zell -Crete Fibers. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 2,500 psi structural concrete or min. 22 ga., Type B, Grade 33 vented steel deck welded to supports spaced max. 6' o.c. with Traxx/5 fasteners spaced 6" o.c. Deck side laps are fastened with Traxx/1 fasteners spaced 12" o.c. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. (Only for Concrete Deck) Elastophene Flam GR or Elastophene Flam LS FR GR torch -applied. Elastocol 500 or Elastocol Stick applied at a rate of 1 gal./sq. Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene HD, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with Millennium Hurricane Force Membrane Adhesive with 0.5 — 1.0 -inch wide ribbons spaced 12 -inch o.c. (Required with self -adhered top sheet) Elastocol 500 or Elastocol Stick applied ata rate of 1 gal./sq. Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam or Soprafix Cap FR -651, fully torch -applied. Or Elastophene Stick FR GR or Soprastar Stick, self -adhered. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -105 psf. with Steel Decking (See General Limitation #9.) -240 psf. with Concrete Decking (See General Limitation #9) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 52 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(6): All General and System Structural Deck: Primer: (Optional) Temp Roof: (Optional) LWIC: Primer: Base Sheet: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: MIAMI.DADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Lightweight Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 2,500 psi structural concrete. Deck primed with ASTM D41 primer. (Sriouth surface sheets) One layer of Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, heat welded Or (Granule surface sheets) One layer of Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, heat welded. Min. 300 psi Celcore MF Cellular Lightweight Concrete deck treated with Celcore PVA Curing Compound Elastocol 500, Elastocol Stick primer at an application rate oi;1 g W q. •. . Colvent Flam TG or Colvent Flam 180 TG, torch -applied. • ... . • •... .. • • • • • • .. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2mlphene SP • 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam. ,•Sopra%ne '. 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopra•Flam X50 • • or Sopralene 250 SP, torch -applied. ••' • • • • Elastophene Flam LS FR GR, Soprastar Flam, Elastophene lair; GR, • Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphgne Flam Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Soba lln$ Flan1180 • FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene: Flam 250 FR+ GR, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 53 of 74 •..... • •• • • •..... • • •.... 00000 •..... • • ...... • • •..... Surfacing: Wausau Lok -Down Paver in Lok -Down over Terra -Stand: The 5 -inch round Terra -Stand base is bonded to the top surface of the waterproofing system in Millennium Hurricane Force Membrane Adhesive at 150 ml per base, followed by Terra -Stand core and top components. The Lok -Down base is then bonded to the top surface of the Terra -Stand in Millennium Hurricane Force Membrane Adhesive at 120 ml per base. Followed by the 2' x 2' Terra -Pavers and the Lok - Down securement tabs and screws. Maximum Design Pressure: -122.5 psf. (See General Limitation #9.) •... • • •..... .... • • .• • . . . • .. . • • . . • .• •.•.•. ...... • .. •.•. • • • • •.•.. •• . 0000 • .• •.•••• •I••• • • •• .. •• .• •.•••• • • . . • 000000 ••••.• • • •.•••• • • 0000•• . •.• • • • • • .. MIAMI.DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 54 of 74 Membrane Type: SBS Deck Type 4: Lightweight Concrete Decks, Non -Insulated Deck Description: Celcore MF Cellular Lightweight Concrete, min. 300 psi System Type F(7): Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Structural Deck: 2,500 psi structural concrete. Primer: Deck shall be primed with ASTM D41 primer. (Optional) Temp Roof: (STooth surface sheets) One layer of Elastophene SP 2.2, Colphene SP 2.2, (Optional) Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene 250 SP, heat welded Or (Granule surface sheds) One layer of Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, heat welded. LWC Deck: Min. 300 psi Celcore MF Cellular Lightweight Concrete deck treated with Celcore PVA Curing Compound. Primer: Deck shall be primed with Elastocol 500 or Elastocol Stick primer at an application rate of 1 gal/sq. ••••• Base Sheet: Colvent Flam TG or Colvent Flam 180 TG, torch -applied. • • • • . .. • • . . Ply Sheet: Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.Z,Mlphene SI' • • (Optional) 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flan 1$Q, Soprae .ne . 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralane Flam:50.. • or Sopralene 250 SP, torch- applied. •••••• • . • • • . • Membrane: Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam t'R GR, • • • • Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flan 180 GR' Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, So,pralepe Flank 1,80: • FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 F'ReR3Dr Sopj4ene. Flam 250 FR+ GR, torch -applied. •. • Integrity Test: Inspection: Surfacing: Maximum Design Pressure: MIAMIOADE COUNTY APPROVED Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Wausau Lok -Down Paver in Lok -Down: The Lok -Down base is bonded directly to the top surface of the waterproofing system in Millennium Hurricane Force Membrane Adhesive at 150 ml per base. Followed by the 2' x 2' Terra - Pavers and the Lok -Down securement tabs and screws. -135 psf. (if using granule surfaced vapor barrier) (See General Limitation #9.) -142.5 psf. (all other applications) (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 55 of 74 ••••.. • • •••••• • •.•••. • •.•.• •..•.. • • • • •.•••. • • •••••• •• • • ••••• • • •..•• •..••• • . ..•••• • • 000000 • • Membrane Type: Deck Type 4: Deck Description: SBS Lightweight Concrete Decks, Non -Insulated Min. 300 psi, min 2 -inch thick Elastizell Range II. System Type F(8): Membranes applied directly to substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Structural Deck: 2,500 psi structural concrete. Temp Roof: (Optional) Substrate Preparation: Primer: Base Sheet: Ply Sheet: Motional) •• • •••• • • • • • ••• .. • • • •S•••• Membrane• • •••• • • •••• • •• • • • •• • • • • • • •• •• • • • •.S••• • . ••• • • Integrity Test: •.•••S •• •• 000000 • • • • • • • • • • • •• Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMFDADE COUNTY APPROVED Elastophene Flam GR or Elastophene Flam LS FR GR torch -applied to deck primed with Elastocol 500 or Elastocol Stick primer applied at a rate of 1 gal/sq. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500, Elastocol Stick or ASTM D 41 primer applied at a rate of 1 gal./sq. Colvent TG, Colvent Flam TG*, Colvent 180 TG, Colvent Flam 180 TG* torch -applied. *requires torch applied top sheet. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch- applied. Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR or Soprastar Sanded adhered with hot asphalt at 20-40 lbs./square. Or Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -145 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 56 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(9): All General and System Substrate Preparation: Primer: Base Sheet: (Optional) Ply Sheet: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry. Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive applied at 1.5 gal/square. Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colpheene 1$0 Sander. • •. Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS.w SQpralege, • •: 250 Sanded adhered with FM Adhesive (VOC), COLPLY Medii •••••• • •• • • • • ••••• ••••• •••••• • .• • • •.•••• • • Membrane Type: Deck Type 3: Deck Description: System Type F(10): SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, Preparation: and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry. Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive applied at 1.5 gal/square. Ply Sheet: Sopra G, Modified Sopra G, Soprabase, Soprabase S, Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, •• • Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene • • • 250 Sanded adhered with FM Adhesive (VOC), COLPLY Modified Adhesive or Soprastar Adhesive applied at 1.5 gal/square. Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR or Soprastar Sanded adhered with FM Adhesive (VOC), COLPLY Modified • Adhesive or Soprastar Adhesive applied at 1.5 gal/square. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Base Sheet: (Optional) •••• • •• •• • • •. • • • • •••••• • •••• r1 1e I rane:• • •• • • • • • • •• •• •S•••• •• •• 1.1111 • • • • L3tiegrfty Testi . . ••• • •• • • Inspection: Surfacing: Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED Exterior grade ceramic plaza deck walking tiles (Minimum size of 12" x 12" and minimum 1/2" thickness) tiles shall be embedded into mud -set Portland Cement applied with a'/<" minimum square notched trowel. Tiles should then be carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. -187.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 58 of 74 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -Insulated Deck Description: Terrace/Plaza Deck, Planter, Traffic System Type F(11): Membranes applied directly to primed substrate. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Elastocol 500 or ASTM D41 primer at an application rate of 100-150 ft2/gallon. Base Sheet: One layer of Sopralene Stick, Colphene Stick, Colvent SA, Self -adhered Primer: Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any (Optional) base or ply sheet prior to application of next layer Ply Sheet: One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene (Optional) Sanded 3.0, Elastophene PS, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded, applied in asphalt at a rate of 251bs./sq. to sand surface base membrane Membrane: One layer of Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR, appliedih• • • • • . hot asphalt at a rate of 25 lbs./sq. ...• •••••• •• • Integrity Test: Required, and shall be performed by an approved lab in accordthicgwith AS.1'1VI•.' •• ••,• D5957. Water may be maintained for a period longer than 24 lfolfit IPrequired. • •• •••• •• • ••••••• • Inspection: Contractor and a representative of the membrane manufacturer.sh • ll•i$spect:the • • • ••••• waterproofing assembly and notify the contractor of any defects! Ine�ection giust . •.; •. • take place prior to installation of any overlay insulation, protec'ttbdpads, drainage: •••••• boards or traffic surfacing. All defects observed shall be correcte*cr •; • • • • . Surfacing: Apply any coating listed in Table 4 above, or any Miami-Dadaap�c+oved cc ting• • (Optional) system. Refer to Underwriters Laboratories or Intertek Testing•9ervaces listings • • • • • •• • for applicable fire classifications. '• • Maximum Design Pressure: -240 psf. (See General Limitation #9.) MIAMIDADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 59 of 74 ...... • .• • • 00•... • • • • •.•.. 000000 • .• • •000000 Membrane Type: Deck Type 4: Deck Description: System Type F(12): All General and System Structural Deck: Vapor Retarder: (Optional) LWC Deck: Primer: Base Sheet: Ply Sheet: (Optional) 0.00 • • 0.00 • • •• . • • •. • • • • • . • • •• • •••000 • •• 0.•• • 0.00 • •• • Membrane: . • • ; • • • •• •• .•• •• • •000.0 • • ••• • • •• .••••• • • • • • • • • • • • •• Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.OADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Membranes applied directly to substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 2,500 psi structural concrete. Elastophene SP 2.2, Elastophene SP 3.0, Colphene SP 2.2, Colphene SP 3.0, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3:5, Sopralene 250 SP, torch -applied over substrate primed with ASTM D41 primer. Min. 300 psi, min 2 -inch thick Celcore MF Cellular Concrete Elastocol 500, Elastocol Stick or ASTM D 41 primer applied at a rate of 1 gal./sq. Colvent TG, Colvent Flam TG*, Colvent 180 TG or Colvent Flam 180 TG* torch -applied. *requires torch applied top sheet. Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene HD, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with hot asphalt at 20-40 lbs/square. Or Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Or Sopralene Stick, Colphene Stick or Sopralene Flam Stick, Self -Adhered. Elastophene GR, Elastophene LS FR GR, Elastophene FR GR, Sopralene 180 FR GR, Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 FR GR or Soprastar Sanded adhered with hot asphalt at 20-40 lbs/square. Or Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -242.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 60 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(13): All General and System Structural Deck: LWIC Deck: Primer: Base/Ply Sheet: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI.DADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 2,500 psi structural concrete. A 1/8" slurry coat of, min. 300 psi, Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with min. 1" thick Holy Board and a minimum 2" thick top coat. After allowing to cure for 24-hour period, Celcore PVA Curing Compound is applied at a rate of 0.33 gal/square. ASTM D 41 primer applied at a rate of 1 gal./sq., to top surface of the LWC deck prior to application of next layer. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 1824R. 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GRA Sopfalene F12tm• • • 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam VS0 Fit GR,; ••. •. OOOOOOSoprastar Flam, Soprafix Cap FR -651, torch -applied. • Required, and shall be performed in accordance with ASTM.DY957 by ar•• • • approved lab. Water may be maintained for a period longer MT 24 hours if • • required. • • • . • ••• •. Contractor and a representative of the membrane manufactitei•tr41 inspect the waterproofing assembly and notify the contractor of any defects. lhspect it i •:. must take place prior to installation of any overlay insulation=pet&ctionpads, drainage boards or traffic surfacing. All defects observed shall be correet8d. ; Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -255 psf. (See General Limitation #9.) •. NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 61 of 74 OOOOOO • • 0000.• . • • • • • • 0.00• •••.•. • •• •0000• • • •••.•- •...•• • • • • • 000000 • • • • •.••. •••... • • • •••••. ••••.. • • Membrane Type: Deck Type 4: Deck Description: System Type F(14): SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Structural Deck: Temp Roof: (Optional) LWC Deck: Primer: (Optional) Base Sheet: • • • • P%%icer: • ••• •• •tOptiAnal) •••••. • Membrane.. ••..• • •• •..• • • •..•• • • •• •• • •• •• • • • • • •• ••v • •••••• • • • • • • • •..•.I • • ,. • • jntfty Test: • • Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMFDADE COUNTY APPROVED 2,500 psi structural concrete Elastophene Flam GR, Elastophene Flam LS FR GR, torch -applied. Min. 300 psi, min 2 -inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. After setting to support foot traffic, Celcore PVA Curing Compound is applied. Elastocol 500 or Elastocol Stick applied at a rate of 1 gal./sq. Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene HD, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with Millennium Hurricane Force Membrane Adhesive with 0.5 -1.0 -inch wide ribbons spaced 12 -inch o.c. (Required with self -adhered top sheet) Elastocol 500 or Elastocol Stick applied at a rate of 1 gal./sq. Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam or Soprafix Cap FR -651, torch -applied. Or Elastophene Stick FR GR or Soprastar Stick, self -adhered. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -255.0 psf. For torch -applied membranes (See General Limitation #9.) -262.5 psf. For self -adhered membranes (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 62 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(15): All General and System Structural Deck: Temp Roof (Optional): LWC Deck: Primer: (Optional) Base Sheet: Primer: Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED SBS Lightweight Concrete Decks, Non -Insulated Elastizell Lightweight Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. 2,500 psi structural concrete. Elastophene Flam GR, Elastophene Flam LS FR GR, torch -applied to deck primed with Elastocol 500 or Elastocol Stick primer applied at a rate of 1 gal/sq. Min. 300 psi, min 2 -inch thick Elastizell Range II. Elastocol 500, Elastocol Stick or ASTM D 41 primer applied at a rate of 1 gal./sq., to top surface of the LWC deck prior to application of next layer. Elastophene HS, Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene HD, Elastophene PS, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 PS 2.2, Elastophene 180 PS, Colphene 180 PS or Sopralene 250 Sanded adhered with Millennium Hurrieaana Force Membrane Adhesive with 0.5 -1.0 -inch wide ribbons saaceel•1•2-inch a cr • • .. .. . Elastocol 500 or Elastocol Stick applied at a rate of 1 gal./sq • •• •• • •• • Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene'Flam FR • GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, !4am 1811PCit . 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GIj,1gpalene 1'1� m • 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flan 25Q j;''R GR,...: • Soprastar Flam or Soprafix Cap FR -651, fully torch -applied Or • • . Elastophene Stick FR GR or Soprastar Stick, self -adhered. ; • • . Required, and shall be performed in accordance with ASTM D 5957 by an • • approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -255.0 psf. For torch -applied membranes (See General Limitation #9.) -302.5 psf. For self -adhered membranes (See General Limitation #9.) • • • • NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 63 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(16): SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Structural Deck: 2,500 psi structural concrete. LWC Deck: Primer: Base Sheet: Ply Sheet: .... • • membranes • • : • •. . •. • . . •.• • • .• .. • • • 4ntegpity Test- • ..•. .... . • • • • • • Inspection: • • •• .. • •• •• Surfacing: (Optional) Maximum Design Pressure: MIAMFDADE COUNTY APPROVED Min. 300 psi, min 2 -inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. After setting to support foot traffic, Celcore PVA Curing Compound is applied. Elastocol 500, Elastocol Stick or ASTM D 41 primer applied at a rate of 1 gal./sq., to top surface of the LWC deck prior to application of next layer. Colvent Flam TG or Colvent Flam 180 TG torch -applied. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250 or Sopralene 250 SP, torch -applied. Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene Flam 250 FR+ GR, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -262.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 64 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(17): SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes applied directly to primed substrate. All General and System Limitations apply. Substrate Preparation: Primer: Base Sheet: Primer: (Optional) Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500 or ASTM D41 primer at an application rate of 100-150 ft2/gallon. One layer of Colvent TG is heat welded Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any base or ply sheet prior to application of next layer One or more layers of Elastophene Sanded, Colphene Sanded, Elastophene Sanded 3.0, Elastophene 180 Sanded, Colphene 180 Sanded, Sopralene 180 Sanded 2.2, Sopralene 180 Sanded, Sopralene 250 Sanded, applied in asphalt at a rate of 25lbs./sq. to sand surfaced base membrane. One layer of Elastophene LS FR GR, Elastophene FR GR, Sopraleng, 180 FR.c1L+ • Colphene 180 FR GR, Sopralene 250 FR GR, Colphene 250 F1tt 1t 4 plied ip asphalt at a rate of 25 lbs./sq. to sand surfaced base or ply memlxaxo.. Required, and shall be performed by an approved lab in accordapgg with ASTM' • D5957. Water may be maintained for a period longer than 24 lipursif required.• • • Contractor and a representative of the membrane manufacturer s'tia1t>;nspect.the. waterproofing assembly and notify the contractor of any defects 1'nspection Must' take place prior to installation of any overlay insulation, protegtioit pgds, dry inagiF boards or traffic surfacing. All defects observed shall be corre.cted.. • • • • Apply any coating listed in Table 4 above, or any Miami -Dade approved co'atTg system. Refer to Underwriters Laboratories or Intertek Testing Services listings'• for applicable fire classifications. -262.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 65 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(18): SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes applied directly to primed substrate. All General and System Limitations apply. Substrate Preparation: Primer: Base Sheet: Primer: (Optional) Ply Sheet: (t$jtienal) • • .. • .• •• • • •. • Membrane: • •• • • • •. • • • • • .• •• • Iwte�rity Test: • • • • ••• • .• 1¢Ispection: • •••. • • •••. • • •. •• Drain Board: (Optional) Surfacing: (Optional) Maximum Design Pressure: MIAMIDADE COUNTY APPROVED All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500, Elastocol Stick or ASTM D41 primer at an application rate of 100- 150 ftz/gallon. One layer of Sopralene Flam Stick*, Sopralene Stick, Colphene Stick, Colvent SA, Self -adhered *Requires heat welded ply or cap membrane Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any base or ply sheet prior to application of next layer One or more layers of Elastophene Flam*, Elastophene Flam 2.2*, Sopralene Flam 180*, Colphene Flam 180*, Sopralene Flam 250*, heat welded *Requires heat welded cap membrane. One layer of Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, heat welded. Required, and shall be performed by an approved lab in accordance with ASTM D5957. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Sopradrain ECO -Vent WR or Sopradrain ECO -2 WR adhered to the top membrane layer with Duotack adhesive applied in 6" spots in a 12 x 12 -inch grid. Min. 12" x 12" x 1" thick concrete pavers installed in ANSI A118.1 mud -set mortar, '/4" minimum notched trowel per ANSI A108.5. -252.5 psf With Drain Board and Concrete Pavers (See General Limitation #9.) -270 psf. Without Drain Board and Concrete Pavers (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 66 of 74 Membrane Type: Deck Type 3: Deck Description: SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic System Type F(19): Membranes applied directly to primed substrate. All General and System Limitations apply. Substrate Preparation: Primer: Base Sheet: Primer: (Optional) Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Drain Board: (Optional) Surfacing: (Optional) Maximum Design Pressure: MIAMI-DADE COUNTY APPROVED All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500, Elastocol Stick or ASTM D41 primer at an application rate of 100- 150 ft2/gallon. One layer of Colvent TG, Colvent Flam TG*, Colvent 180 TG or Colvent Flam 180 TG*, heat welded. *requires torch applied top sheet Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any base or ply sheet prior to application of next layer One or more layers of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP • 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 18D, Cgjphene F • 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 1 AQ SP 3.5, • • • Sopralene Flam 250, Sopralene 250 SP, heat welded . . • • .. • One layer Elastophene Flam LS FR GR, Soprastar Flam, Elastopjige Flam FR• . GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colltgin Flam );80'.. • GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR,S pralene Flaw . 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 25€141 dR, Soprlalens Flam 250 FR+ GR, heat welded .•• Required, and shall be performed by an approved lab in accordance with ANI• • D5957. Water may be maintained for a period longer than 24lhcw•rsif requireji. • Contractor and a representative of the membrane manufacturer shall inspect the . • waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Sopradrain ECO -Vent WR or Sopradrain ECO -2 WR adhered to the top membrane layer with Duotack adhesive applied in 6" spots in a 12 x 12 -inch grid. Min. 12" x 12" x 1" thick concrete pavers installed in ANSI A118.1 mud -set mortar, '/4" minimum notched trowel per ANSI A108.5. -252.5 psf. With Drain Board and Concrete Pavers (See General Limitation #9.) -292.5 psf. Without Drain Board and Pavers (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 67 of 74 Membrane Type: Deck Type 4: Deck Description: System Type F(20): SBS Lightweight Concrete Decks, Non -Insulated Celcore MF Cellular Concrete, min. 300 psi. Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. All General and System Limitations apply. Structural Deck: Primer: Vapor Barrier: LWIC Deck: 0000 • • •.•• • •• •• . . primer: • .. •... •• Brise Sheet: • 000 • • • • . . • • .• .• •• •• • • ▪ . • • .. • • . • • • Meml3rane:••• • • •.. . •• •. Integrity Test: Inspection: Surfacing: (Optional) Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED 2,500 psi structural concrete. Concrete shall be primed with ASTM D 41 primer applied at a rate of 1 gal./sq. Elastophene Sanded, Colphene Sanded, Sopralene 180 Sanded, Elastophene 180 Sanded, Colphene 180 Sanded or Sopralene 250 Sanded adhered with FM Adhesive or COLPLY Adhesive at 1.5 gal/square OR Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene 180 SP 3.0 or Sopralene 180 SP 3.5 or Colphene 180 SP 3.5, torch - applied. A 1/8" slurry coat of, min. 300 psi, Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture with min. 1" thick Holy Board and a minimum 2" thick top coat. After allowing to cure for 24-hour period, Celcore PVA Curing Compound is applied at a rate of 0.33 gal/square. Primed with ASTM D 41 primer applied at a rate of 1 gal./sq., to top surface of the LWC deck prior to application of next layer. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene Flam FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 GR 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Soprastar Flam, Soprafix Cap FR -651, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. - 262.5 psf. with adhesive applied vapor barrier (See General Limitation #9.) - 360 psf. with torch applied vapor barrier (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 68 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(21): All General and System Substrate Preparation: Primer: Base Sheet: Ply Sheet: (Optional) Membrane: Integrity Test: Inspection: Drain Board: (Optional) Surfacing: (Optional) Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. All surfaces must be dry, smooth, free of depressions, voids and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Concrete deck shall be primed with ASTM D 41 primer and allowed to dry. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene SP 3.0, Colphene SP 3.0, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5 or Sopralene Flam 250, torch -applied. .•••• • •.•• Elastophene Flam GR, Elastophene Flam LS FR GR, Elastophene lam FP. . GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Soprelen f4am 180 3.5, Sopralene Flam 180 FR GR, Colphene Flam 180 FR G1r,Sdjit'dlene Flan? 180 FR GR 3.5, Sopralene Flam 250 FR GR, Colphene Flam?SO TzR GR.; ••. •. ... . .• Soprastar Flam, Soprafix Cap FR -651, torch -applied. Required, and shall be performed in accordance with ASTM' D 3957 by an• • • • • approved lab. Water may be maintained for a period longerah5.424 hours if • required. • • • • Contractor and a representative of the membrane manufacturer shall inspect she. waterproofing assembly and notify the contractor of any defects. Inspection •• • must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Sopradrain ECO -Vent WR or Sopradrain ECO -2 WR adhered to the top membrane layer with Duotack adhesive applied in 6" spots in a 12 x 12 -inch grid. Min. 12" x 12" x 1" thick concrete pavers installed in ANSI A118.1 mud -set mortar, 14" minimum notched trowel per ANSI A108.5. -252.5 psf. with Drain Board and Pavers (See General Limitation #9.) -367.5 psf. without Drain Board and Pavers (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 69 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(22): SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes applied directly to primed substrate. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Primer: Elastocol 500, Elastocol Stick or ASTM D41 primer at an application rate of 100- 150 ft2/gallon. Base Sheet: Primer: (Optional) Ply Sheet: (Aptional) • • 0.00 • .• • . • .. • Membrane: • • • . • • •• • • • . • •• • •.0• . • 0000 • • • • . • ..• •.• •• • •. . Integrity Tat:. . • • •• . • • ..• .• •• tispection: Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED One layer of Colvent TG, Colvent Flam TG*, Colvent 180 TG or Colvent Flam 180 TG*, heat welded. *requires torch applied top sheet Elastocol 500, Elastocol Stick applied at a rate of 1 gal./sq., to top surface of any base or ply sheet prior to application of next layer One or more layers of Elastophene Flam, Elastophene Flam 2.2, Elastophene SP 2.2, Colphene SP 2.2, Elastophene 180 SP, Sopralene Flam 180, Colphene Flam 180, Sopralene 180 SP 3.0, Sopralene 180 SP 3.5, Colphene 180 SP 3.5, Sopralene Flam 250, Sopralene 250 SP, heat welded One layer Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR, Sopralene Flam 250 FR+ GR, heat welded Required, and shall be performed by an approved lab in accordance with ASTM D5957. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Exterior grade ceramic plaza deck walking tiles (Minimum size of 12" x 12" and minimum Y2" thickness) tiles shall be embedded into mud -set Portland Cement applied with a'/e" minimum square notched trowel. Tiles should then be carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. -292.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 70 of 74 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -Insulated Deck Description: Terrace/Plaza Deck System Type F(23): Membranes applied directly to substrate with Tile surfacing. All General and System Limitations apply. Substrate All surfaces must be dry, smooth, free of depressions, voids, and protrusions, and Preparation: clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Substrate shall be smooth, free of voids, spalled areas, laitance, honeycombs, and sharp protrusions. Primer: Elastocol 500, Elastocol Stick or ASTM D 41 primer applied to deck at a rate of 100-150 ftz/gal. Base Sheet: One or more plies of Elastophene Flam or Sopralene Flam 180, Colphene Flam 180, Sopralene Flam 250, heat welded according to manufacturer's application instruction. Membrane: Elastophene Flam LS FR GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam Antirock or Soprastar Flam heat welded according to manufacturer's applicalYM • instruction. • • "' • •. • •. •• • Integrity Test: Required, and shall be performed by an approved lab in accordafel With ASkTM•• • D5957. Water maybe maintained for a period longer than 24 hodrtSf required. • ••.. .. • Inspection: Contractor and a representative of the membrane manufacturer the..' waterproofing assembly and notify the contractor of any defect'riggectiorgmujst take place prior to installation of any overlay insulation, protec'ifon'Pads, draft ge• boards and traffic surfacing. All defects observed shall be coriecl .: • Surfacing: • • • • • . . • • • Exterior grade ceramic plaza deck walking tiles (Minimum size of f1'2 ' x 12V and • . minimum 1/2” thickness) tiles shall be embedded into mud -set PMitlantl Cemmfir• applied with a'/o" minimum square notched trowel. Tiles should then be • • carefully embedded in the mortar bed and tapped in place to insure full solid bearing. Tile shall be installed in accordance with applicable Building Code. Maximum Design Pressure: -457.5 psf. (See General Limitation #9) MIAM4DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 71 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(24): All General and System Existing Roof: Substrate Preparation: Primer: Membrane: Integrity Tec{.• • • .. • •• • .• • • Jnsgegtion: • • •••• • •• • . • . • .•• •• • • 1 • •• •• • • • • Surfacing: ..• �pfional) • • • Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED SBS Concrete Decks, Non -Insulated Terrace/Plaza Deck, Planter, Traffic Membranes adhered to primed substrate for Terrace/Plaza Decks, Planters or Traffic Areas. Limitations apply. Fully adhered, granule surfaced, SBS modified bitumen. All surfaces must be dry, smooth, free of depressions, voids, and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Elastocol 500 or ASTM D 41 primer applied to deck at a rate of 100-150 ft2/gal. Elastophene Flam LS FR GR, Soprastar Flam, Elastophene Flam FR GR, Elastophene Flam FR+ GR, Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180 FR GR, Colphene Flam 180 FR GR, Sopralene Flam 180 FR+ GR, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene Flam 250 FR+ GR, torch -applied. Required, and shall be performed in accordance with ASTM D 5957 by an approved lab. Water may be maintained for a period longer than 24 hours if required. Contractor and a representative of the membrane manufacturer shall inspect the waterproofing assembly and notify the contractor of any defects. Inspection must take place prior to installation of any overlay insulation, protection pads, drainage boards or traffic surfacing. All defects observed shall be corrected. Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. Refer to Underwriters Laboratories or Intertek Testing Services listings for applicable fire classifications. -572.5 psf. (See General Limitation #9.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 72 of 74 Membrane Type: Deck Type 3: Deck Description: System Type F(25): SBS Concrete Decks, Non -Insulated Min. 2500 psi, dual slab construction (roof plaza and parking decks) Membranes applied directly to primed substrate with concrete surfacing. All General and System Limitations apply. Substrate Preparation: Primer: Base Sheet: Membrane: Integrity Test: Inspection: Protection Board and/or Drainage Layer: (Optional) Surfacing: Maximum Design Pressure: MIAMI•DADE COUNTY APPROVED All surfaces must be dry, smooth, free of depressions, voids, and protrusions, and clean and free of any non -compatible curing compounds, foam release agents and other surface contaminants. Substrate shall be smooth, free of voids, spalled areas, laitance, honeycombs, and sharp protrusions. Elastocol 500, Elastocol Stick or ASTM D 41 primer applied to deck at a rate of 100-150 ft2/gal. One or more plies of Sopralene Flam 180 or Sopralene Flam 250, heat welded according to manufacturer's application instruction. Sopralene Flam 180 GR, Colphene Flam 180 GR, Sopralene Flam 180, Sopralene Flam 250 FR GR, Colphene Flam 250 FR GR or Sopralene Flam Antirock, heat welded according to manufacturer's application instruction. ...• • Required, and shall be performed by an approved lab in accorccnc�'byith AS'Fikf • D5957. Water maybe maintained for a period longer than 24 ho1..frs if requiJ Contractor and a representative of the membrane manufacturer dial} inspect the, waterproofing assembly and notify the contractor of any defer s •I'tt5pectio: iNu9t. take place prior to installation of any overlay insulation, protect&! pads, di ain4t boards and traffic surfacing. All defects observed shall be correota. .' • • •• •• •.• •. • • Install drainage board over top ply membrane • • • • • • •• • . • Structural Concrete Slab, minimum 2500 psi, in compliance with applicable .• •• Building Code. N/A (Topping concrete slab shall comply with applicable Building Code requirement.) NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 73 of 74 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. All work shall be performed by a Contractor licensed to do roofing/waterproofing and be a Manufacturer Trained 'Qualified Applicator' approved by SOPREMA. SOPREMA shall supply a list of approved applicators to the authority having jurisdiction. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. Insulation attachment shall not be acceptable. 6. • Fsitener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a ' • rni imum fas4enQr resistance value in conjunction with the maximum design value listed within a • • • smific systerfi? Should the fastener resistance be less than that required, as determined by the Building • • • Official, a'tlsf1§t�1 fastener spacing, prepared, signed and sealed by a Florida registered Professional • .•. . ngineer, Re�rsiered Architect, or Registered Roof Consultant may be submitted. Said revised fastener • ' . spaoing sh&O..�1tze the withdrawal resistance value taken from Testing Application Standards TAS 105 •• • • anc� calculgtigujri compliance with Roofing Application Standard RAS 117. 7.:.Perimeter aril' Cerner areas shall comply with the enhanced uplift pressure requirements of these areas. ' • Fastener drsit4eC shall be increased for both insulation and base sheet as calculated in compliance with • • aQQfng Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered • • ProflsssionarUngiteer, Registered Architect, or Registered Roof Consultant (When this limitation is • •: s{iecifically referred within this NOA, General Limitation #9 will not be applicable.) 8. • All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. A non-skid surfacing is required for all pedestrian areas, plaza decks or balconies. 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 12. Required integrity flood testing shall be provided to the Building Official for review at time of final inspection. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 16-0229.05 Expiration Date: 09/18/18 Approval Date: 07/14/16 Page 74 of 74